Loading…
Loading…
Tender Value
₹119.9 Cr
EMD Value
₹2.4 Cr
Closing Date
3 Jul 2026, 3:00 pmClosed
Construction of ICD maintenance facilities including Vande Bharat trains at Ranavav under Bhavnagar Division on Western Railway.
DyCE-C-JAM-RANAVAV-01~WR
DyCE-C-JAM-RANAVAV-01
Open
Works - General
15 Months
Bhavnagar, Gujarat
₹0
₹2.4 Cr
3 Jul 2026
10 Jun 2026
19 Jun 2026
C-USSOR Earthwork in formation Items 64622433.54 Below/P
E-Cement and Steel USSOR Items 146356015.04 Below/P
J-NS Item for Pit line and Shed 261759365.90 Below/P
Supply and using Cement at Worksite Ordinary Portland Cement 53 grade of approved brands/makes
Item Breakup - A-DSR Items
Item Breakup - B-DSR Steel Items
Item Breakup - C-USSOR Earthwork in formation Items
Using Soil Class SQ2 Earthwork in cutting in formation, trolley refuges, side drains, level crossing approaches, platforms, catch water drains, diversion of nallah & finishing to required dimension and slopes to obtain a neat appearance to standard profile inclusive of all labour, materials, plant & machinery, leading all cut spoils either to make spoil dumps or for filling in embankment with leads within 2 km on either side of edge of the cutting(s) including all lifts, ascent, descent, loading, unloading, bailing & pumping out water, if required, clearance of site and all other works incidental thereto for completing the work as per RDSO Specification No. RDSO/2020/GE: IRS-0004 with latest updated correction slips and to the satisfaction of the Engineer-in- Charge. Note: (i) All usable earth arising from cut spoils shall be led into bank formation and Unusable spoils shall be dumped / stacked away from toe of embankment. (ii) All hard rock /and boulders not fit for filling will be stacked by the contractor and will be property of the Railways. (iii)Cut trees shall be property of Railways and to be deposited in the railway godown unless specified otherwise in the Conditions of Contract.
In all conditions and classifications cum of soil except rock DYCE-C-II-RJT-ENGINEERING/WESTERN RLY
Mechanical blanketing material by using only hard and durable stone crushed in mechanical crusher to different gradations, wet mixing of the same in designed proportion in Pug mill or wet mix plant to have uniform gradation including all incidental transportation, laying over finished formation in uniform layer(s) with motor grader, compaction with suitable vibratory roller to specified density and finishing to correct profile, complete as per RDSO Specification No. RDSO/2020/GE: IRS-0004 with latest correction slips. Note: This item shall be used only when entire constituent of blanketing material is mechanically manufactured by crushing of hard and durable stone into desired gradation of designed proportion. Total 144529186.00
Item Breakup - D-USSOR Bridge Items
On top of subgrade or prepared Sqm subgrade before laying blanketing layer with minimum strengths in Grab test, Trapezoidal Tear test and Puncture test of 700N, 250 N and 1800 N respectively. DYCE-C-II-RJT-ENGINEERING/WESTERN RLY Earthwork in excavation by mechanical means (Hydraulic Excavator)/Manual Means for foundations and floors of the bridges, retaining walls etc. including setting out, dressing of sides, ramming of bottom, getting out the excavated material, back filling in layers with approved material and consolidation of the layers by ramming and watering etc. including all lift, disposal of surplus soil up to a lead of 300m, all types of shoring and strutting with all labour and material complete as per drawing and technical specification as directed by Engineer in charge. Note: This item will be used for excavation work in connection with other miscellaneous works also like side drains, foundation for OHE masts and other miscellaneous structures in connection with Gauge Conversion, Doubling, New lines.
All kinds of soils Providing and laying in position Plain cement concrete of specified Nominal Mix f o r miscellaneous works like side drains, foundation for OHE masts and other miscellaneous structures excluding the cost of Cement, centering and shuttering - All work up to plinth level :
1:1½:3 (1 Cement: 1½ coarse sand cum (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Providing and laying in position cum machine batched, machine mixed and machine vibrated Cement Concrete of specified grade as per approved Design Mix (mixed in Mobile Concrete Batching/Mixing Plant at site or RMC from approved p l a n t s ) using 20mm graded crushed stone aggregate and coarse sand of approved quality in RCC raft foundation & Pile cap including finishing, using Plasticiser in approved proportions (as per IS:9103), to modify workability without impairing strength and durability complete as per specifications and direction of the Engineer in charge. N o t e : 1. Payment for cement, reinforcement and shuttering shall be made extra under relevant item. 2. Plasticiser shall invariably be used in approved proportion to increase workability with minimum possible quantity of cement for all grade of Design Mix Concrete unless it is specifically approved citing reasons for not using plasticiser at the stage of Mix Design and in that case deduction shall be made as per relevant item. DYCE-C-II-RJT-ENGINEERING/WESTERN RLY Providing and laying in position machine batched, machine mixed and machine vibrated Cement Concrete of specified grade as per approved Design Mix (mixed in Mobile Concrete Batching/Mixing Plant at site or RMC from approved plants) using 20mm graded crushed stone aggregate and coarse sand of approved quality for the following Reinforced cement concrete structural elements up to height of 9.0 m from foundation top level, including finishing, using Plasticiser in approved proportions (as per IS:9103), to modify workability without impairing strength and durability complete as per specifications and direction of the Engineer in charge. Note: 1. Payment for cement, reinforcement and shuttering shall be made extra under relevant item. 2. Plasticiser shall invariably be used in approved proportion to increase workability with minimum possible quantity of cement for all grade of Design Mix Concrete unless it is specifically approved citing reasons for not using plasticiser at the stage of Mix Design and in that case deduction shall be made as per relevant item.
Abutment & Pier
Wing wall and Return wall
Abutment cap, Pier Cap, Inspection cum Platform & Pedestal over Pier cap, Fender wall, Diaphragm wall etc.
Approach slab at formation level, cum Dirt wall/ ballast wall at formation level
Providing and fixing Weep Holes in Metre Abutments, Wing walls and Return walls etc., of new bridges with 110mm dia UPVC pipe Type A ISI marked with all contractor's men, material, transportation, all taxes as per specifications and as directed by Engineer-in-Charge. DYCE-C-II-RJT-ENGINEERING/WESTERN RLY
P r o v id in g and casting machine cum batched, machine mixed and machine vibrated Cement Concrete of specified grade as per approved Design Mix, mixed in Mobile Concrete Batching/Mixing Plant at site or RMC from approved plants, (Cast in-Situ/Pre-cast) in bottom/top slab, side walls, toe wall and sumps haunch filling head walls, thrust bed or any other component using 20mm graded crushed stone aggregate and coarse sand of approved quality of RCC box of any size including finishing, Plasticiser in approved proportions (as per IS:9103), to modify workability without impairing strength and durability, complete as per drawings and technical specifications as directed by Engineer in charge. N o t e : 1. Payment for cement, reinforcement and shuttering shall be made extra under relevant item. 2. Plasticiser shall invariably be used in approved proportion to increase workability with minimum possible quantity of cement for all grade of Design Mix Concrete unless it is specifically approved citing reasons at the stage of Mix Design and in that case deduction shall be made as per relevant item.
Providing and applying two coats Sqm of coal tar or bitumen confirming to IS:3117- latest version on the top and sides of RCC box/slabs @ 1.70 kg/sqm after cleaning the surface with all labour and materials complete job as directed by the Engineer. Centering and shuttering including strutting, propping etc. and removal of form for :
All types of bridge sub-structures, Sqm e.g. pier, abutment, wing wall, retaining wall, RCC box type foundations, Abutment cap, Pier Cap, Inspection Platform & Pedestal over Pier cap, Fender wall, Diaphragm wall etc. up to 5m above ground level
All structures, e.g. slabs, I-girders, T- girders, Box girders etc. up to 5m above ground level. DYCE-C-II-RJT-ENGINEERING/WESTERN RLY
Providing and launching in position cum machine batched, machine mixed and machine vibrated Cement Concrete of specified grade as per approved Design Mix (mixed in Mobile Concrete Batching/Mixing Plant at site or RMC from approved plants) using 20mm graded crushed stone aggregate and coarse sand of approved quality for the Precast Prestressed (Post- tensioned) Concrete Girder/Box Girders/Slabs in contactor's casting yard in the vicinity of worksite, including finishing, using Plasticiser in approved proportions (as per IS:9103), to modify workability without impairing strength and durability, complete as per drawings, specifications and direction of the Engineer. Note: 1. Payment for Shuttering, Cement, Reinforcement, HTS cables, Sheathing, Anchorage Cones, stressing of cables, grouting of the ducts and launching of girder/slab in position shall be made extra under relevant items. However, deduction shall be made in case of slab as per relevant item. 2. For pre-cast item, loading in transport vehicle in casting yard is included and shall not be paid extra. 3. Plasticiser shall invariably be used in approved proportion to increase workability with minimum possible quantity of cement for all grade of Design Mix Concrete unless it is specifically approved citing reasons at the stage of Mix Design and in that case deduction shall be made as per relevant item.
Design, manufacturing, supplying Cubic and fixing in position elastomeric Centimetre b e a r i n g true to line and level conforming to IS:3400, IS:226, BS- 5400 under prestressed concrete girders/ Steel Girders, for Pre-cast as well as cast-in-situ girders as per approved drawing. The rate shall include cost of load test of one no. bearing from Railway approved firms and all fixing materials, equipments, machineries, labour, taxes, loading, unloading, leading, lifting etc. complete. Rates include getting the drawing approved from Railway and cost of inspection during manufacturing from railway approved organization.Note : 1. The rate is for finished item complete and paid only after fixing in position below the girder. 2. The volume shall be as given in the drawing and no deduction shall be made for inserted steel plates etc. DYCE-C-II-RJT-ENGINEERING/WESTERN RLY Providing and fixing in position of standard preformed sealed and slab type or strip seal elastomeric type expansion joints for Railway bridge or Road Over Bridges as per approved drawings and latest MORTH/IRC specifications complete in all respect as directed by Engineer in-charge.
For 160mm expansion Load testing of one or more spans of bridge as selected by the Engineer as per approved load test procedure following relevant IS/IRC/Railway codes with contractor's labour, deflection measuring instruments, loading materials, recording and analyzing the load testing results including all lead & lift, etc. complete as required. The rates are all inclusive and will be paid after load test is finished and girder is cleared of the kentledges/loading material etc. The load shall be 1.25 times the stipulated design load.
For Span design load up to 100 MT Each
Extra for every increase of 1 MT or MT part thereof over 100 MT in the span design load capacity up to 800 MT
Applying Epoxy Poly-sulphate Paint Sqm three coats on existing bottom surface of deck slab including cleaning surface of dirt, dust & other foreign matter, sand papering, wire brushing as required with all contractor's materials tools, machinery, scaffolding, lead, lifts etc. complete as per specifications and as directed by Engineer in-charge
Deduction in rate of 031010, cum 031020 and 031030 for casting of slab in place of Girder for any height Metallizing of steel work of girders with sprayed aluminium after surface preparation by Sand/grit blasting, followed by one coat of etch primer (IS:5666) & one coat of Zinc Chrome primer (IS:104) and two coats of aluminium paint (IS:2339) with all labour, T&P and material as a complete job duly conforming to all relevant specifications and process given under Clause 39 of IRS-B1-2001. Note: Nominal Thickness of sprayed Aluminium coating shall be 150 microns. DFT of Zinc chrome primer shall be 25-30 microns and DFT of each coat of Aluminium paint shall be 12-14 microns.
On new girder during fabrication DYCE-C-II-RJT-ENGINEERING/WESTERN RLY Launching in position, by any approved method, pre-fabricated Steel Girders, precast PSC girders/slabs, casted at casting bed developed at site, to correct alignment and level over the bed block / pedestal with all required arrangements, complete in all respect.
PSC girders / slabs
Supplying weighing not less than 35 kg each at specified bridge locations.
Providing and laying of filter media cum consisting of granular materials of GW, GP, SW groups as per IS:1498 (latest) in required profile behind boulder filling of abutments, wing walls / return walls etc. above bed level with all labour and material complete job as per drawing and technical specification of RDSO Guidelines.
Painting the HFL mark and Danger Each level mark, year of HFL on bridge abutments and piers with ready mixed paint as per standard in two coats over one coat of primer with all materials, labour, tools, scaffolding, all lead and lift etc. including writing complete.
Providing cast in situ bridge Each number plaques as per Railway drawing in cement concrete 1:2:4 mix using 20mm hard stone aggregate embedded in 30mm notch in Bridge parapet coping duly engraving the letter and figures and an arrow indicating the direction of flow and finishing the top exposed surface with cement mortar 1:3, painting letters and figures with two coats of black enamel paint on two coats of white background with all labour, tools, cement, paint etc. with all leads and lifts.
Providing cast in-situ plaques for Each bridge foundations details of size 45cmx45cmx5cm in cement concrete 1:2:4 mix using 20mm hard stone aggregate embedded in 30mm deep notch over abutment & piers, engraving the letters & figures with CM 1:3 and finished smooth including painting letters and figures with 2 coats of black enamel and plaque with white enamel with all labour, tools, cement, paint, curing etc. as a complete job.
Providing Boulder Backing behind cum wing wall, return wall, retaining wall with hand packed boulders & cobbles with smaller size boulders toward the back including all lead, lift, labour & other incidental charges as complete work in all respect. Payment for boulder/cobbles will be done extra. DYCE-C-II-RJT-ENGINEERING/WESTERN RLY Total 91527633.96
Item Breakup - E-Cement and Steel USSOR Items
Thermo-Mechanically Treated bars Kg of grade Fe-500D or more of approved brands/makes.
Providing, fabricating & fixing in MT position to exact design profiles, H.T.S. cables of all classification made from Low Relaxation strands conforming to IS:14268- latest version in Prestressed (Post- tensioned) Concrete girders/slabs etc. including supplying, cutting, making into cables with necessary spacers, colour coding, protecting with water soluble oil at all time, anchoring of cables, supplying and placing spiral corrugated type galvanized metal steel ducts sheathing made up of Cold Rolled Cold Annealed (CRCA) mild steel conforming to IS:513 of required diameter/ thickness, vent pipe, placing, bending, routing, fixing, stressing & grouting of cable ducts with cement grout, Anchorage sets in required number with provision for future prestressing if any including all lead and lift with contractor's own materials, labour, equipments etc. complete as per drawings & specifications. Rate also includes covering anchorage pads with epoxy mortar of approved quality to avoid corrosion. Cement for grouting to be paid separately. Payment shall be made in terms of weight of HTS cables as per drawing. DYCE-C-II-RJT-ENGINEERING/WESTERN RLY
Supplying fabricating and erecting MT welded and/or bolted and/or riveted steel work in built up sections, trusses and framed work, staging, racks, Height Gauge etc. for Steel Structures other than bridge girders, using RSJ, tees, angles and channels/flats, plates, gussets, round or square bars, cleats, bolts etc., with contractors own steel including cutting, bending, straightening, drilling, riveting, hoisting, fixing, erecting, welding, bolting etc., with Providing stiffeners wherever required as per approved drawing including applying a priming coat of a approved steel primer with all contractor's materials, labour, tools & plants, lead & lift including crossing of tracks if required etc., complete as per specification and as directed by Engineer-in-charge. Note: The payment shall be made on the theoretical weight of main components and gusset plates only. Total 217081007.18
Item Breakup - F-USSOR P way Items
In-situ situation DYCE-C-II-RJT-ENGINEERING/WESTERN RLY Under conditions not requiring Traffic Block: Dismantling of existing BG turnouts, diamond crossings and derailing switches with all types of rails and sleeper layout, removing rails, switches, crossings, sleepers & fastenings, leveling of ballast to correct profile & stacking all the released materials, sleepers, fastenings, rails, switches & crossings including segregating & stacking at specified locations in a neat and countable manner, within the lead of 250m & all lift, clear of infringements, crossing of track, if any complete, as directed - Note: 1. This item shall be operated only when existing turnout is replaced either with new turnout in case of T T R or with plain track when existing turnout is no more required at that location. 2. Rail cutting will be paid extra under relevant item. 3. Laying of new turnout or plain track on prepared ballast bed, as required, shall be paid separately under relevant item.
1 in 8½ Turnout (Under conditions Set not requiring Traffic Block).
1 in 12 Turnout (Under conditions Set not requiring Traffic Block).
1 in 16 Turnout (Under conditions Set not requiring Traffic Block). Laying and linking of turnouts of all types including diamond crossings & Derailing switches with 52Kg / 60Kg rail section on PSC sleepers on prepared ballast bed for New lines or during total closure of section at indicated location as per standard drawing, duly leading sleepers, rails, switches, crossings, fastenings including rail cutting, drilling, fixing of all components, fittings with housing of tongue rails as per requirement of signaling, preparing ballast bed, filling and spreading of ballast as required, linking of turnout with track, attending track parameters including lifting, providing one round of packing to make track fit for 20 kmph speed including lubrication of fittings/fastenings, complete as directed by Engineer in-charge.
1 in 8½ Turnouts
1 in 12 Turnouts
Derailing Switch DYCE-C-II-RJT-ENGINEERING/WESTERN RLY 25mm gap 'in-situ' welding during traffic block and finishing of weld to meet the prescribed tolerances and pass all stipulated tests with all required labour, materials, consumables, tools, equipments etc. to complete the work in all respect as per IR's "Manual for Fusion Welding of Rails by Alumino - Thermic Process" with latest correction slips, including marking of welded joint, painting weld collar with anticorrosive paint, restoration of track near weld joint to original position and fixing of joggled fish plate at new weld, to be removed after passing of weld in USFD test as directed by Engineer in charge. Note: 1. Welding shall be carried out only by trained welder having valid competency certificate using RDSO approved Alumino Thermit Welding Portions, 3 piece prefabricated mould (ZIRCON WASHED) manually pressed, Single shot crucible fitted with auto tapping thimble and Compressed Air Petrol/LPG preheating technique as per RDSO Specification No IRST/19-2020 with latest amendment. 2. Hydraulic Weld trimmer shall be used for chipping and profile Grinder for finishing. 3. Only required nos. of Joggled fish plates shall be supplied by Railway at nearest P. Way Stores and the same shall be returned at nearest P. Way Store or at other location as per direction of Engineer-in-Charge after release from track. All other items required shall be supplied by the Contractor.
For 60 Kg - 90 UTS Rail DYCE-C-II-RJT-ENGINEERING/WESTERN RLY 25mm gap Cess Welding and finishing of weld to meet the prescribed tolerances and pass all stipulated tests with Contractor's labour, materials, consumables, tools, equipments etc. to complete the work in all respect as per IR's "Manual for Fusion Welding of Rails by Alumino - Thermic Process" with latest correction slips, including all required handling and rehandling of rails, marking of welded joint, painting weld collar with anticorrosive paint, as directed by Engineer in charge. Note: 1. Welding shall be carried out only by trained welder having valid competency certificate using RDSO approved Alumino Thermit Welding Portions, 3 piece prefabricated mould (Zircon washed) manually pressed, Single shot crucible fitted with auto tapping thimble and Compressed Air Petrol/LPG preheating technique as per RDSO Specification No IRST/19-2020 with latest amendment. 2. Hydraulic Weld trimmer shall be used for chipping and profile Grinder for finishing.
For 60 Kg - 90 UTS Rail Flash Butt Welding of 90 UTS rails and finishing of weld to meet the prescribed tolerances and pass all stipulated tests, conforming to IR's Manual for Flash Butt Welding of Rails with latest amendment, using contractor's self-propelled rail cum road / Mobile FBW Plants, tools, equipments and consumables. Item also includes painting with anticorrosive paint as approved and marking of welded joints, pre- straightening & post-straightening of panels and USFD testing of finished weld as directed by Engineer in-charge.
60 Kg 'in-situ' under traffic block DYCE-C-II-RJT-ENGINEERING/WESTERN RLY
Spreading of ballast, from existing cum stacks available along formation on top or at cess, in required uniform thickness, compaction of ballast layer laid on new formation at all the locations with smooth wheeled power roller of 8-10 tonne capacity to sufficient number of passes to form consolidated ballast bed of approximately 250mm thickness to a width of 4m symmetrical to centre line of proposed track in correct line & level with all ascents & descents, as directed by Engineer in-charge. Note: Item is inclusive of (a) providing ramp for taking roller to formation and removing the same & making good formation after completion of work; (b) redistribution & leveling of excess ballast while rolling to obtain uniform plane cambered surface. Linking of BG track (except at LC, Bridges and SEJs) with any type of rail section and sleeper of specified density, on ballast bed spread and compacted with suitable roller, over prepared formation including leading free rails/welded panels available along the alignment on to formation, leading and spreading all fittings and fastenings, spreading of sleepers at specified spacing, squaring, placing of rails over sleepers and fixing rails to sleepers with all types of fittings and fastenings to correct gauge & alignment, lubrication of fittings and fastenings with contractor's grease as per IRPWM standards with contractors labour, tools, consumables, with all lead, lifts etc. complete and raising, levelling and initial packing of track to make it fit for 30 kmph and meet other prerequisites prescribed in Indian Railway Track Machine Manual for deployment of Tamping Machine. N o t e : 1.Rail cutting and Hole drilling shall be paid separately. 2.Spreading of ballast and compaction shall be paid separately under relevant item.
For sleeper density sleepers per km DYCE-C-II-RJT-ENGINEERING/WESTERN RLY Anti-corrosive painting of rail on running track of any sleeper density on web, foot etc. including liner contact area (excluding bottom of foot) and fishing plane as per requirement with two coats o f thickness of 100 microns each by bituminous black paint confirms to IS-9862 of reputed make including painting of liners, ERCs and including surface preparation, as a complete job as per procedure prescribed in latest edition of IRPWM Note: 60% of payment shall be made if painting on only gauge face side is done.
For 60 Kg Rails Marking, inscribing, painting, writing, bordering etc. on new / old iron surface at various locations of Points & Crossings with details of turn-in / turn-out reference station mark on rail web for one set, duly preparing surface with contractor's wire brush and applying two coats of yellow synthetic enamel paint of approved quality as background and stenciling the details to suitable size, as described for every curve reference station mark / switch / crossing details with black enamel paint of approved quality complete, as directed : Note: Stenciling of letters is only permitted. No hand written letters are accepted.
1 in 12 Turnout
1 in 8½ Turnout Quick cutting with abrasive rail cutter of all types of rail sections including wear resistant, head hardened rails up to 110 UTS, with contractors tools & plants, equipment, consumable with all lead & lift etc. complete as directed by Engineer in-charge. Abrasive Rail Cutter will be as per RDSO Specification No. TM/SM/1 (Rev. 01 of 2012) with latest status of RDSO; Rail Cutting Wheel Abrasive Disc will be as per RDSO Specification No.TM/SM/2 (Rev. 01 of 2020)
60 Kg - 110/90 UTS - On Running Each Line Drilling holes of 16 mm to 32 mm dia. with Rail Drilling machine including chamfering with appropriate chamfering tools in all types of rail section with contractor's tools & plants, equipment, consumable with all lead & lift etc. complete, as directed by Engineer in-charge. Rail Drilling Machine will be as per RDSO Specification No. TM/SM/3, dated 24.04.1991.
On Running Line DYCE-C-II-RJT-ENGINEERING/WESTERN RLY Loading of rails of any section and length up to 13 metres in Wagons / Truck / trailer including lead up to 50 metres and lift up to 5 metres.
I n Wagon handling is possible a n d traffic block is not required or in Truck/trailer. Loading of tongue rail, stock rail, switch assembly and crossings of any section and length, SEJ, Glued joint etc. with / without P.Way fittings and fastenings, in Wagon / Truck / trailer including lead up to 250 metre and lift up to 5 metre.
I n Wagon handling is possible a n d traffic block is not required or in Truck/trailer. Unloading of rails of any section and length up to 13 metre, in neat manner for Railway usage from departmental material train (DMT) or contractor's / Railway's Truck/trailer including lead up to 50 m e t r e , lift up to 5 metre and stacking in prescribed manner.
From Wagon where mechanical MT handling is possible a n d traffic block is not required or in Truck / trailer. Loading of 52kg / 60kg PSC normal line and special sleepers up to 2.75 metre length in Depot / Station / Mid-section between stations in a neat manner to departmental material train (DMT) or contractor's / Railway's Truck/Trailer with crane or any other means including crossing of one track with free lead up to 250 metre and lift up to 5 metre, if required with contractor's labour, tools & plants, machinery, consumables etc. Note: In case of any damage to sleeper during loading, penalty @ 50% of the all inclusive cost of sleeper shall be levied.
I n Wagon handling is possible a n d traffic block is not required or in Truck / trailer DYCE-C-II-RJT-ENGINEERING/WESTERN RLY Loading of 52kg / 60kg PSC line and special sleepers beyond 2.75 metre length including existing fittings and fastenings in Depot / Station / Mid-section between stations in a neat manner to departmental material train (DMT) or contractor's / Railway's Truck/trailer with crane or any other means including crossing of one track with free lead up to 250 metre and lift up to 5 metre, if required with contractor's labour, tools & plants, machinery, consumables etc. Note: In case of any damage to sleeper during loading, penalty @ 50% of the all inclusive cost of sleeper shall be levied.
I n Wagon/Truck / trailer where MT mechanical handling is possible and traffic block is not required. Loading, leading and unloading of all types of P.Way fittings and all other miscellaneous material except Rails, sleepers, switches, crossings, SEJs and Glued Joints by road vehicles for different leads. Note: Lead shall be the shortest motorable road length between the points of loading and unloading.
Lead beyond 50 Km and up to 100 MT Km
Lead beyond 100 Km and up to MT 150 Km
Extra for every Km per MT beyond MT-Km 150 Km over item no. 172047 Transportation of Rails, sleepers, switches, crossings, SEJs and Glued Joints by road vehicles for different leads. Note: 1 . Lead shall be the shortest motorable road length between the points of loading and unloading. 2. Loading and unloading shall be paid extra under relevant items.
Lead beyond 50 Km and up to 100 MT Km
Lead beyond 100 Km and up to MT 150 Km
Extra for every Km per MT beyond MT-Km 150 Km over item no. 172057 Unloading of 52kg / 60kg PSC line and special sleepers up to 2.75 metre length in Depot / Station / Mid-section between stations in neat manner for Railway usage from departmental material train (DMT) or contractor's / Railway's Truck/Trailer with crane or any other means including crossing of one track and lead up to 250 metre & lift up to 5 metre with contractor's labour, tools & plants, machinery, consumables etc. Note: In case of any damage to sleeper during loading, penalty @ 50% of the all inclusive cost of sleeper shall be levied. DYCE-C-II-RJT-ENGINEERING/WESTERN RLY
From Truck / Trailer Unloading of 52kg / 60kg PSC special sleepers beyond 2.75 metre length in Depot / Station / Mid-section between stations in neat manner for Railway usage from departmental material train (DMT) or contractor's / Railway's Truck/Trailer with crane or any other means including crossing of one track and lead up to 50 metre & lift up to 5 metre with contractor's labour, tools & plants, machinery, consumables etc. Note: In case of any damage to sleeper during loading, penalty @ 50% of the all inclusive cost of sleeper shall be levied.
From Truck / Trailer Unloading of Switches / Crossings / SEJ Rails / Glued Joints of any rail section and length with or without P.Way fittings & fastenings in neat manner for Railway usage from departmental material train (DMT) or contractor's / Railway's Truck/Trailer with lead up to 250 metre & lift up to 5 metres.
From Truck / Trailer Manufacturing, fabricating and supplying retro-reflective Engineering Indicator boards, made of 2mm thick aluminium sheet or 3mm thick aluminium composite sheet, face to be fully covered with high intensity encapsulated type heat activated retro-reflective sheeting conforming to type-IV of ASTM- D4956-01 in yellow & black or other colour combination including subject matter, message, symbols, borders etc. as approved by Engineer In-charge or as per IRPWM guidelines, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D- 4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back-support frame of M.S. angle iron of size 25mm x25mm x 3mmprovided all along the edges of board with theft resistant measures back side of board shall be with non-peelable weatherproof paint, consisting of one coat of zinc chromate primer and two coats of epoxy paint. Vertical post shall have black & white anti-corrosive paint or powder coating complete, as directed.
Caution Indicator Board of size Each 1400mmx400mm with back support frame fixed to vertical post of MS angle of size 50mmx50mmx6mm of 3650 mm long DYCE-C-II-RJT-ENGINEERING/WESTERN RLY
Speed equilateral triangular shape having each side of 1000mm with back support frame fixed to vertical post of MS angle of size 50mmx50mmx6mm of 3650 mm long
Stop Indicator Board of size Each 1400mmx400mm with back support frame fixed to vertical post of MS angle of size 50mmx50mmx6mm of 3650 mm long
Manufacturing, fixing Curve Indicator / Point Indicator / SEJ Boards to be provided at various locations on formation, made out of MS sheet 2mm thick of size 450mm x 300mm duly fixed with MS frame of 25mm x 25mm x 3mm angle welded to 50mm x 50mm x 3mm MS angle, 1000mm long post split and bent 100mm at bottom end with all lead & lift as per specification and including painting of details with enamel paint, as directed by Engineer in-charge (Earthwork & concreting will be paid separately)
Supply and fixing in position pre- Each cast cement concrete Fouling Mark as per approved drawing at station yard, duly painting the top surface and slopes with white enamel paint in two coats and inscribed letters with black of Fouling Mark, complete in all respects with all labour, materials including cement, tools and plants etc. Hiring of machinery for minor miscellaneous works for short duration including operator/driver, fuel, lubricants and consumable. The contractor shall arrange all statutory permits as required by rules and regulations prevailing in the area of work. Payment shall be made for actual working hours at site.
JCB Backhoe Loaders 3DX Plus or Hour similar with minimum 1.10 cum bucket capacity Total 23624052.01
Item Breakup - G-USSOR Ballast Supply
When distance of nearest quarry is cum more than 50 km and up to 100 km Total 26141750.00
Item Breakup - M-Electrical (GS)
Erection Total 3425662.00 Supply, installation, testing and commissioning of HT VCB 11KV, 800Amp, complete with all Item- 2 accessories. ( One No). S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 1337996.00 Item- 3 Supply, installation, testing and commissioning of sandwich Aluminium insulated Bus truncking. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 3474800.00 Supply, install, testing & commissioning of 400 KVAR automatic power factor correction capacitor Item- 4 bank . S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 363319.00 Item- 5 Supply, install, testing & comissining of 50 KVAR automatic power factor correction capacitor bank . S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 356400.00 Supply, fabrication, installation, testing & Commissioning of Main LT panel I/C-2x1600 Amp 4-pole Item- 6 ACB, O/G- 6 x 800A 4-pole ACB, 6 x 400A 4-pole MCCB, 6 x 250A 4-pole MCCB, 9 x125A 4-pole MCCB & 1x1000A 4-pole on-load changeover switch. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 2262282.00 Supply, fabrication, installation, testing & Commissioning of LT switch board panel consisting- Item- 7 Incoming 2 x 600A, 4-pole ACB & Outgoing 6 x 250A, 4-pole MCCB, 6 x 125A, 4-pole MCCB, with 400A, 4-pole on load change over switch. S No. Item No Description of Item Unit Qty Rate Amount
Supply DYCE-C-II-RJT-ENGINEERING/WESTERN RLY
Erection Total 780083.00 Supply, fabrication, installation, testing & Commissioning of LT Panel I/C-2x400 4-pole MCCB, O/G- Item- 8 4x250A 4-pole MCCB, 4x125A 4-pole MCCB, 4 x63A 4-pole MCCB. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 656036.00 Supply, fabrication, installation, testing & Commissioning of LT Panel consisting- Incoming 2 x 250A Item- 9 4-pole MCCB & Out going -6x125A 4-pole MCCB & 2 x 63 A 4-pole MCCB. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 2049912.00 "Supply, installation,testing and commissioning of 1000KVA outdoor type 11KV/750V DYN 11, Item- 10 ONAN connected transformers energy efficient on suitable foundation and with fencing as per technical specification shown in Para (A) of Annexure" S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 3039366.00 Supply, installation, testing and commissioning of HT VCB 11KV, 630Amp, complete with all Item- 11 accessories. ( One No). S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 1523608.00 "Supply, installation,testing and commissioning of LT panel suitable for operation 750V 3 phase and neutral supply having 1000A ACB FP microprocessor MDO type as incoming and 2Nos. 630A. Item- 12 ACB FP microprocessor MDO type with Ameter, voltmeter,indicator lamp,multi functionmeter etc. as per technicalspecification shownin Para (C) of Annexure." S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 877450.00 Supply, installation, testing and commissioning of in door end termination kit suitable for 3.3/6.6 Item- 13 KV(UE) HT XLPE Armoured Alluminium cable of 3 Core 240 Sq.mm S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 178530.00 Supply, installation, testing and commissioning of heat shrinkable in door end termination kit Item- 14 suitable for 3.3/6.6 KV(UE) HT of single Core 240 Sq.mm S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 32820.00 Supply, installation, testing and commissioning of LHB type socket assembly 400 Amp. As per part Item- 15 No. SI/LHB/CSA/00/CAB housed in stainless steel housing of size 3 ft x 2 ft x 2ft with one contector AC 3 series 370 Amp 415V AC coil to on / off set fixing stand to be cement concret foundation. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 1651352.00 Supply, installation, testing and commissioning of Double ended jumper plug assembly with 10 Mtr. Item- 16 Polyamid conduit and copper 120 sq mm cable for phase and 95 sq mm for neutral for LHB type coupler. S No. Item No Description of Item Unit Qty Rate Amount
Supply DYCE-C-II-RJT-ENGINEERING/WESTERN RLY
Erection Total 1122012.00 Supply, install, testing & comissining of HT 11KV (E) grade outdoor type heat shrinkable type cable Item- 17 termination box suitable for 3-core, 185 sqmm XLPE cable. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 50052.00 Supply, installation and commissioning of HT 11KV (E) grade indoor type heat shrinkable type cable Item- 18 termination box suitable for 3-core, 185 sqmm XLPE cable. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 115920.00 Supply,installation, testing & commissioning of heat shrinkable type straight through joint for 3- Item- 19 core,185sqm, XLPE 11KV(E) HT cable. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 58248.00 Supply, fabrication, installation, testing & Commissioning of Distribution board consisting- Incoming Item- 20 1 x 125 A 4-pole MCCB & Out going - 8 x 63 A , 4 pole MCB, 2x20A DP MCB . S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 274164.00 Item- 21 Supply installation, Testing & commissioning of 400A feeder pillar. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 238420.00 Item- 22 Supply installation, Testing & commissioning of 250 Amp feeder pillar. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 140168.00 Supply, fixing, testing & commissioning of Battery charge/discharge unit Input Voltage : 415 V AC, Item- 23 50 HZ, output Voltage : 110 V DC - 155 V DC, output current : 0-300 A as per RDSO's specifications S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 3891576.00 Item- 24 Fabrication, supply, fixing & commissioning of 110V battery charging terminals. (EFT) S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 103770.00 Item- 25 Fabrication, supply, fixing & commissioning of welding terminals. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 103770.00 Supply, installation, testing & commissioning of 3 phase, 415 V 63 A, heavy duty plug-socket socket Item- 26 complete with 63 Amp 3-pole MCCB and 20A ray roll plug and Socket with 20A DP MCB in M.S. enclosure. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 878220.00 Item- 27 Supply, installation, testing & commissioning of 20 W LED fitting with 110 V, AC operated. DYCE-C-II-RJT-ENGINEERING/WESTERN RLY S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 747520.00 Supply, installation, testing & commissioning of step down transformer 440/110 V AC 3 phase,5 Item- 28 KVA for LED fitting. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 60448.00 Item- 29 Digging of cable trench 450 x 1000 mm & refilling as per Specification. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 1050800.00 Item- 30 Digging of cable trench 450 x 1000 mm in RCC/PCC/hard soil. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 1596450.00 Transportation, Laying,Installation , terminating, testing and commissioning of LT/HT cable of sizes Item- 31 Core 1/2/3/4 x 10 sqmm to core 1/2/3/4 x 400 sqmm in existing trench, pipe or on structure. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 719600.00 Item- 32 Supply, installation, testing & Commissioning of LT/HT cable route marker. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 31720.50 Item- 33 Supply and laying of RCC half round pipe 100 mm ID & 1 mtr length. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 400350.00 Item- 34 Supply and laying of RCC half round pipe 150 mm ID & 1 mtr length. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 212800.00 Supply, installation, testing and commissioning of HDPE pipe 110 mm nominal dia 6.2 mm Item- 35 thickness as per IS 4984-1995. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 365760.00 Horizontal Direction Drilling/boaring without demage of surface raod using auger machine the bore Item- 36 shall be 150mm dia and shall be done at the depth of minimum 1.5meter or as requirement of site from the ground level this include insertation of 110mm dia 7mm thickness HDPE pipe . S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 592900.00 Supply, transportation, installation, testing & Commissioning of SDB Switch board consisting- Item- 37 Incoming 1 x 63 A 4-pole MCB & Out going -8 x 32 DP MCB , 12 x 16 A SP MCB . S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 155988.00 Supply, installation, testing & commissioning of Distribution board having incoming-32 A DP MCB Item- 38 and outgoing- 6 x16A SP MCB. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 79786.00 DYCE-C-II-RJT-ENGINEERING/WESTERN RLY Supply,installation, testing & commissioning of 5mtr long hot dip galvanised octagonal poles with Item- 39 130 mm bottom & 70 mm top made up of 3mm thick steel sheet along with base plate of size 200x200x12mm with foundation. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 710066.00 Item- 40 Supply, installation, testing & commissioning of 45 system watt LEDstreet light fitting. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 934934.00 Supply, installation, testing & commissioning of surface wiring of light, fan and call bell point with Item- 41 modular switch by 3 nos. 1.5 sq mm FRLS PVC insulated copper conductor multi-strand single core in PVC casing caping and accessories. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 42471.00 Supply, installation, testing & commissioning of surface wiring of plug point 6 Amps with modular Item- 42 switch on same board by 3 nos. 1.5 sq mm FRLS PVC insulated copper conductor multi-strand single core in PVC casing caping and accessories S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 5461.00 Supply, installation, testing & commissioning of surface wiring of modular plug point 16/6 Amps Item- 43 with modular switch on separate board by 3 nos. 4.0 sq mm FRLS PVC insulated copper conductor multi-strand single core in PVC casing caping and accessories. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 8838.00 Supply, erection, testing & commissioning of surface wiring of sub-main from board to board and Item- 44 room to room with 3 nos. 2.5 sq mm FRLS PVC copper conductor, multi-strand single core in PVC casing caping and accessories. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 25900.00 Supply, erection, testing & commissioning of surface wiring of sub-main from board to board and Item- 45 room to room with 3 nos.4.0 sq mm FRLS PVC copper conductor, multi-strand single core in PVC casing caping and accessories. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 26500.00 Supply, erection, testing & commissioning of surface wiring of sub-main from board to board and Item- 46 room to room with 3 nos.6.0 sq mm FRLS PVC copper conductor, multi-strand single core in PVC casing caping and accessories. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 12640.00 Supply, erection, testing & commissioning of wiring of 2 way light point with modular switch by 4 Item- 47 nos. 1.5 sq mm FRLS PVC copper conductor, multi-strand single core in PVC conduit pipe/ casing caping. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 2712.00 Item- 48 Supply and providing musical call bell. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 2800.00 DYCE-C-II-RJT-ENGINEERING/WESTERN RLY Supply,installation, testing and commissioning of ceiling fans including hooks, clamps, nuts & bolts Item- 49 etc. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 113850.00 Item- 50 Supply, fixing, testing & commissioning of serface type modular electronic fan regulator. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 8316.00 Supply, installation, testing & commissioning of 10/20 W LED bulk head fitting with 230 Volt AC Item- 51 operated. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 32952.00 Supply, installation, testing and commissioning of Concealed wiring of light, fan and call bell point Item- 52 with Modular switch by 3 nos. 1.5 sq mm FRLS PVC insulated copper conductor multi-strand single core in PVC conduit pipe & Conduit pipe accessories. S No. Item No Description of Item Unit Qty Rate Amount
erection Total 338650.00 Supply, installation, testing and commissioning of Concealed wiring of plug point 6 Amps3 pin with Item- 53 Modular switch on same board by 3 nos. 1.5 sq mm FRLS PVC insulated copper conductor multi- strand single core in PVC conduit pipe & Conduit pipe accessories . S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 51798.00 Supply, erection, testing & commissioning of Concealed wiring of plug point 16 Amps 6 pin with Item- 54 Modular switch by 3 nos. 4.0 sq mm FRLS PVC insulated copper conductor multi-strand single core in PVC conduit pipe & Conduit pipe accessories. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 44770.00 Supply, erection, testing & commissioning of concealed wiring with 3 nos. 2.5 sq mm sub-main Item- 55 FRLS PVC copper conductor, multi-strand single core in PVC conduit pipe. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 190820.00 Supply, installation, testing and commissioning of concealed wiring of sub-main with 3 nos. 4.0 sq Item- 56 mm FRLS PVC copper conductor, multi-strand single core in PVC conduit pipe. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 168640.00 Supply, erection, testing & commissioning of concealed wiring of sub-main from board to board and Item- 57 room to room with 3 nos.6.0 sq mm FRLS PVC copper conductor, multi-strand single core in PVC casing caping and accessories. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 81780.00 Supply, erection, testing & commissioning of concealed wiring of sub-main from board to board and Item- 58 room to room with 5 nos.10.0 sq mm FRLS PVC copper conductor, multi-strand single core in PVC conduit pipe. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 62400.00 Item- 59 Supply, installation, testing and commissioning of concealed 100W modular fan regulator. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 24024.00 DYCE-C-II-RJT-ENGINEERING/WESTERN RLY Supply, installation, testing and commissioning of exhaust fan 300 mm complete with all Item- 60 accessories. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 27760.00 Item- 61 Supply, installation, testing & commissioning of 1x (18-20) W LED tube fittings . S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 389246.00 Supply and providing recess mounted LED Fitting- (36@45&41@ W , 2x2 sq ft with flexible, 3-core, Item- 62 multistrand copper conductor, PVC insulated & sheathed wire of required size. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 253440.00 Supply, installation, testing & commissioning of Corrosion proof LED fitting (Capsule type fitting) Item- 63 suspended, surface type-2 x (18 to 20)W LED tube fittings . S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 109356.00 Supply, installation, testing and commissioning of 3 nos.4.0 sq mm FRLS PVC copper conductor, Item- 64 multi-strand single core in PVC casing caping/ PVC conduit and accessories for Cover shed wiring. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 246000.00 Supply, installation, testing and commissioning of 16 sqmm aluminium conductor PVC insulated and Item- 65 sheathed catenary wire. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 78000.00 Supply, installation, testing and commissioning of 600mm sweep air circulator fan including Item- 66 mounting accessories. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 94930.00 Supply and providing switch board of suitable size having 16/6A plug socket with 16A switch and Item- 67 two Nos. 6A switch. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 6402.00 Item- 68 Supply, installation, testing & commissioning of junction box S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 93504.00 Supply, installation, testing & commissioninog of LED Light fitting 250 watt complete with Item- 69 accessories. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 1818870.00 Supply, installation, testing & commissioninog of LED Light fitting 90 Watt complete with Item- 70 accessories. S No. Item No Description of Item Unit Qty Rate Amount
Supply DYCE-C-II-RJT-ENGINEERING/WESTERN RLY
Erection. Total 1217944.00 Supply, installation, testing & commissioninog of LED focus Light fitting 30 Watt complete with Item- 71 accessories. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 180300.00 Supply, installation, testing & commissioning of Auto control of portal light light Distribution board Item- 72 having Time switch , contactor and MCB . S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 40607.00 Item- 73 Supply and providing 50mm dia UPVC Pipe. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 38720.00 Item- 74 Supply of material and providing 600 x 600 x 3.5 mm copper plate earthing. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 433132.00 Item- 75 Supply,installation, testing & commissioning of Pipe earthing. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 149912.00 Item- 76 Supply,installation, testing & commissioning of 8 SWG G.I. earth Wire. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 37440.00 Item- 77 Supply, fabrication, installation, testing & Commissioning of MS cable tray. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 951060.00 Supply, installation, testing and commissioning of 5-7.5 HP, three phase vertical submersible pump Item- 78 sets. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 21974.00 Supply, installation, testing and commissioning of 5-7.5 HP, three phase vertical submersible pump Item- 79 sets. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 19959.00 Supply, installation, testing and commissioning of control panel for 5-7.5 HP, three phase Item- 80 submersible pump . S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 6002.00 Item- 81 Supply and providing 50 mm dia. UPVC Column pipe. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 91360.00 Item- 82 Supply and providing 3 core, 4 sqmm copper flat cable suitable for submersible pump. S No. Item No Description of Item Unit Qty Rate Amount DYCE-C-II-RJT-ENGINEERING/WESTERN RLY
Erection. Total 41410.00 Supply, installation, testing & commissioning of submersible Horizontal mono block pump to be Item- 83 installed in sump suitable for 415 V three phase supply & 5.0 HP. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 21974.00 Supply of submersible Horizontal mono block pump to be installed in sump suitable for 415 V three Item- 84 phase supply & 5.0 HP (As spare). S No. Item No Description of Item Unit Qty Rate Amount
Supply. Total 20765.00 Supply, installation, testing and commissioning of control panel for 5.0 HP mono-block submersible Item- 85 pump. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 6002.00 Supply, Erection, Testing & Commissioning of sub-mersible non clog pump set complete with all accessories, motor starter, and base plate of cap.36 LPS Discharge on 10 mtrs. Head (approx. 10 Item- 86 HP/7.5 KW) complete with automation control panel, Flate cable ( cooper) , suction & delivery pipes, clamps etc S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 449616.00 Item- 87 Providing FL Mast 20 mtrs S No. Item No Description of Item Unit Qty Rate Amount
Erexction Total 901000.00 Item- 88 Foundation for FL mast. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 202108.00 Supply, installation, testing & commissioninog of LED Light Flood light fitting 250 W on high mast Item- 89 and other location, complete with all accessories. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 792864.00 Item- 90 Fabrication, supply and erection of G.I. Structure(portal) S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 2058720.00 Item- 91 Cement concrete foundation for the above GI Structure (Portal) S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 383680.00 Supply,installation, testing & commissioning of 5 star invertor split type Air conditioning unit of 1.5 Item- 92 ton capacity complete with all accessories for mounting of AC unit. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 394840.00 DYCE-C-II-RJT-ENGINEERING/WESTERN RLY "Supply, erection, testing & commissioning of :- Concealed wiring of plug point 20 Amps with Item- 93 Modular switch by 3 nos.4.0 sq mm FRLS PVC insulated copper conductor multi-strand single core in PVC conduit pipe & Conduit pipe accessories for AC & Geyser " S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 8056.00 Item- 94 Dismantling & stacking of Rail /Tubular pole with removal of O/H lines S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 9090.00 Item- 95 Excevation of all kind of soil (except Rock) and filling back the excavated earth as per Specification. S No. Item No Description of Item Unit Qty Rate Amount
erection. Total 21646.00 Item- 96 Excevation of Hard soil (Stone/Rock/RCC) and filling back the excavated earth as per Specification. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 140620.00 Item- 97 Supply, installation, testing & commissioning of Straight through Jointing Kit of size 4x70-95 Sq mm S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 43335.00 Supply, installation, testing & commissioning of Straight through Jointing Kit of size 4x120-150 Sq Item- 98 mm S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 47268.00 Supply, installation, testing and commissioning of 500 KVA DG set complete with AMF Panel as per Item- 99 Specification. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 3514484.00 Item- Supply, installation, testing and commissioning of 250 KVA DG set complete with AMF Panel as per 100 Specification. S No. Item No Description of Item Unit Qty Rate Amount
Erection Total 3268000.00 Item- Supply, testing and demonstration of maintenance staff tool boxes complete 101 S No. Item No Description of Item Unit Qty Rate Amount
Supply Total 64408.00 Item- Supply , erection, fixing, testing & commissioning of stainless steel body water cooler 150 liters 102 capacity. S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 131316.00 Item- Supply of 8 locker Steel cup board. 103 S No. Item No Description of Item Unit Qty Rate Amount
Supply. Total 8640.00 Item- Supply of Almirah steel. 104 DYCE-C-II-RJT-ENGINEERING/WESTERN RLY S No. Item No Description of Item Unit Qty Rate Amount
Supply. Total 8724.00 Item- Supply of Steel chair. 105 S No. Item No Description of Item Unit Qty Rate Amount
Supply. Total 1626.00 Item- Supply of Steel table. 106 S No. Item No Description of Item Unit Qty Rate Amount
Supply. Total 6472.00 Item- Supply of Light duty drill machine 107 S No. Item No Description of Item Unit Qty Rate Amount
Supply. Total 17546.00 Item- Supply of Portable blower. 108 S No. Item No Description of Item Unit Qty Rate Amount
Supply. Total 12264.00 Item- Supply of clip on meter 109 S No. Item No Description of Item Unit Qty Rate Amount
Supply. Total 17246.00 Item- Supply of earth tester 110 S No. Item No Description of Item Unit Qty Rate Amount
Supply. Total 11862.00 Item- Supply of insulation tester 111 S No. Item No Description of Item Unit Qty Rate Amount
Supply. Total 5004.00 Item- Supply of 8 feet ladder 112 S No. Item No Description of Item Unit Qty Rate Amount
Supply. Total 9192.00 Item- Supply and providing 11 KV , ISI mark rubber matting of size; 1Mtr width & 2.5 mm thick. 113 S No. Item No Description of Item Unit Qty Rate Amount
Supply. Total 88308.00 Item- Supply & providing Dry chemical type Fire fighting Equipment. 114 S No. Item No Description of Item Unit Qty Rate Amount
Supply. Total 17844.00 Item- Supply of Fire bucket . 115 S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 7020.00 DYCE-C-II-RJT-ENGINEERING/WESTERN RLY Item- Supply of Self supporting Aluminium ladder -15 feet. 116 S No. Item No Description of Item Unit Qty Rate Amount
Supply. Total 18288.00 Item- Supply, testing and commissioning of RMPU maintenance ladder. 117 S No. Item No Description of Item Unit Qty Rate Amount
Supply. Total 93394.00 Item- Supply of hand Gloves 11 kv 118 S No. Item No Description of Item Unit Qty Rate Amount
Supply. Total 708.00 Item- GI strip size-50x6 mm with PVC sleeve 119 S No. Item No Description of Item Unit Qty Rate Amount
Erection. Total 13560.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .