| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAccepted-AOC 6 GOODS SHED ROAD TITAGARH KOLKATA 700119 | TITAGARH | NORTH 24 PARGANAS | WEST BENGAL | 700119 | L1 | Accepted-AOC Work Order Issued | |
| 2 | L2₹1.7 L+₹21,700 (14.4%)Rejected-Finance DANGAPARA KANCHRAPARA | KANCHRAPARA | WEST BENGAL | L2 | Rejected-Finance NOT L1 BIDDER | |
| 3 | L3₹1.7 L+₹22,300 (14.8%)Rejected-Finance B 16 280 KALYANI NADIA 741235 | KALYANI | NADIA | WEST BENGAL | 741235 | L3 | Rejected-Finance NOT L1 BIDDER |
| Sl No | Description | Qty | Unit | REFRICON L3 | ARATI ENTERPRISE L1 | FREEZER L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & delivery 1.5 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 18000 BTU/hr. with 1 no. rotary compressor, 1 no. IDU of rated power supply - 230 V - 1 ph - 50 Hz. , 1 no. ODU of rated power supply - 230 V -1 ph - 50 Hz Air-flow/per IDU:- 650 CFM., Refrigerant: R-410A ( Make: Hitachi/Mitsubishi Electric). | 1 | Set | 55,000 ₹55,000 | 53,800 ₹53,800 | 53,000 ₹53,000 Lowest |
| 2.00 | Supply & delivery 2 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1 no. rotary compressor, 1 no. IDU of rated power supply - 230 V - 1 ph - 50 Hz., 1 no. ODU of rated power supply - 220 V - 1 ph - 50 Hz. Air-flow/per IDU:- 800 CFM., Refrigerant: R-410A ( Make: Hitachi/Mitsubishi Electric). | 1 | Set | 68,000 ₹68,000 | 64,200 ₹64,200 Lowest | 67,000 ₹67,000 |
| 3.00 | Installation, testing and commissioning of 1.5/1.8/2.0 Tr. split AC Machine with IDU&ODU including supply & fixing of 40 mm x 40 mm x 5 mm MS angle iron brackets (powder coated) with necessary nut- bolt etc. & mending good the damages. | 2 | Nos. | 6,000 ₹12,000 | 4,800 ₹9,600 Lowest | 6,500 ₹13,000 |
| 4.00Supply & laying of the following sizes Refrigerant Copper Pipe (Minimum thickness 0.9 mm and Make - Royku / Totaline / Mandeep) with insulation by nitril rubber of minimum thickness 9 mm [Make Aroflex / Acoflex] also raping the insulation & Copper wire with GKB Gold non-adhesive tape. | ||||||
| 4.10 | 6.35 mm (1/4") dia | 8 | Mtr. | 800 ₹6,400 | 440 ₹3,520 Lowest | 900 ₹7,200 |
| 4.20 | 12.7 mm (1/2") dia | 8 | Mtr. | 850 ₹6,800 | 640 ₹5,120 Lowest | 950 ₹7,600 |
| 4.30 | 15.88 mm (5/8") dia | 16 | Mtr. | 900 ₹14,400 | 720 ₹11,520 Lowest | 1,000 ₹16,000 |
| 5.00 | Supply & drawing 1.1 KV Gr. 3 core 2.5 sq. mm. P.V.C. insulated copper cable for connecting the Power hub to ODU. (Make - Havells / Finolex / RR Kabel) | 10 | Mtr. | 100 ₹1,000 | 98 ₹980 Lowest | 120 ₹1,200 |
| 6.00 | Supply & drawing 1.1 KV Gr. 4 core 1.5 sq. mm. P.V.C. insulated copper cable for connecting the ODU TO IDU. (Make - Havells/ Finolex/ RR Kabel) | 10 | Mtr. | 120 ₹1,200 | 102 ₹1,020 Lowest | 150 ₹1,500 |
| 7.00 | Supply & laying 3/4" heavy type P.V.C. pipe for Water Drainage as per direction. | 20 | Mtr. | 100 ₹2,000 | 58 ₹1,160 Lowest | 80 ₹1,600 |
Tender Value
Refer Docs
EMD Value
₹3,022
Closing Date
8 Jan 2026, 11:55 amClosed
Assistant Engineer
OFFICE OF THE ASSISTANT ENGINEER Kalyani Electrical Sub-Division, PWD Kalyani, Nadia
Replacement of existing split AC at Doctors room of Cath Lab and Augmentation of AC at Server Room at Gandhi Memorial Hospital, Kalyani, Nadia.
2025_WBPWD_967806_1
WBPWD/AE/e-NIT- 06/KLY(3rd call) of 2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Gandhi Memorial Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,022
OFFICE OF THE ASSISTANT ENGINEER Kalyani Electrica
10 Mar 2026
4 Dec 2025
13 Jan 2026
4 Dec 2025
13 Jan 2026
9 Dec 2025
8 Dec 2025
Amount
Supply & delivery 1.5 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 18000 BTU/hr. with 1 no. rotary compressor, 1 no. IDU of rated power supply - 230 V - 1 ph - 50 Hz. , 1 no. ODU of rated power supply - 230 V -1 ph - 50 Hz Air-flow/per IDU:- 650 CFM., Refrigerant: R-410A ( Make: Hitachi/Mitsubishi Electric).
Supply & delivery 2 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1 no. rotary compressor, 1 no. IDU of rated power supply - 230 V - 1 ph - 50 Hz., 1 no. ODU of rated power supply - 220 V - 1 ph - 50 Hz. Air-flow/per IDU:- 800 CFM., Refrigerant: R-410A ( Make: Hitachi/Mitsubishi Electric).
Installation, testing and commissioning of 1.5/1.8/2.0 Tr. split AC Machine with IDU&ODU including supply & fixing of 40 mm x 40 mm x 5 mm MS angle iron brackets (powder coated) with necessary nut- bolt etc. & mending good the damages.
Supply & laying of the following sizes Refrigerant Copper Pipe (Minimum thickness 0.9 mm and Make - Royku / Totaline / Mandeep) with insulation by nitril rubber of minimum thickness 9 mm [Make Aroflex / Acoflex] also raping the insulation & Copper wire with GKB Gold non-adhesive tape.
6.35 mm (1/4") dia
12.7 mm (1/2") dia
15.88 mm (5/8") dia
Supply & drawing 1.1 KV Gr. 3 core 2.5 sq. mm. P.V.C. insulated copper cable for connecting the Power hub to ODU. (Make - Havells / Finolex / RR Kabel)
Supply & drawing 1.1 KV Gr. 4 core 1.5 sq. mm. P.V.C. insulated copper cable for connecting the ODU TO IDU. (Make - Havells/ Finolex/ RR Kabel)
Supply & laying 3/4" heavy type P.V.C. pipe for Water Drainage as per direction.
Dismantling of existing damaged 1.5T/2T AC Machine from its position and handed over to authority.
Supplying and fixing Al. powder coated continuous grill.
Charges for lifting of Indoor & Outdoor units & Scaffolding Arrangement.
FREEZER (BID ID -7813162)
REFRICON (BID ID -7806429)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .