| 1 | L1₹1.5 LAccepted-AOC 6 GOODS SHED ROAD TITAGARH KOLKATA 700119 | TITAGARH | NORTH 24 PARGANAS | WEST BENGAL | 700119 | ₹1.5 L | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹1.7 LRejected-Finance DANGAPARA KANCHRAPARA | KANCHRAPARA | WEST BENGAL | ₹1.7 L | L2 | Rejected-Finance NOT L1 BIDDER |
| 3 | L3₹1.7 LRejected-Finance B 16 280 KALYANI NADIA 741235 | KALYANI | NADIA | WEST BENGAL | 741235 | ₹1.7 L | L3 | Rejected-Finance NOT L1 BIDDER |
| Sl No | Description | Qty | Unit | REFRICON L3 | ARATI ENTERPRISE L1 | FREEZER L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & delivery 1.5 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 18000 BTU/hr. with 1 no. rotary compressor, 1 no. IDU of rated power supply - 230 V - 1 ph - 50 Hz. , 1 no. ODU of rated power supply - 230 V -1 ph - 50 Hz Air-flow/per IDU:- 650 CFM., Refrigerant: R-410A ( Make: Hitachi/Mitsubishi Electric). | 1 | Set | 55,000 ₹55,000 | 53,800 ₹53,800 | 53,000 ₹53,000 |
| 2.00 | Supply & delivery 2 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1 no. rotary compressor, 1 no. IDU of rated power supply - 230 V - 1 ph - 50 Hz., 1 no. ODU of rated power supply - 220 V - 1 ph - 50 Hz. Air-flow/per IDU:- 800 CFM., Refrigerant: R-410A ( Make: Hitachi/Mitsubishi Electric). | 1 | Set | 68,000 ₹68,000 | 64,200 ₹64,200 | 67,000 ₹67,000 |
| 3.00 | Installation, testing and commissioning of 1.5/1.8/2.0 Tr. split AC Machine with IDU&ODU including supply & fixing of 40 mm x 40 mm x 5 mm MS angle iron brackets (powder coated) with necessary nut- bolt etc. & mending good the damages. | 2 | Nos. | 6,000 ₹12,000 | 4,800 ₹9,600 | 6,500 ₹13,000 |
| 4.00Supply & laying of the following sizes Refrigerant Copper Pipe (Minimum thickness 0.9 mm and Make - Royku / Totaline / Mandeep) with insulation by nitril rubber of minimum thickness 9 mm [Make Aroflex / Acoflex] also raping the insulation & Copper wire with GKB Gold non-adhesive tape. | ||||||
| 4.10 | 6.35 mm (1/4") dia | 8 | Mtr. | 800 ₹6,400 | 440 ₹3,520 | 900 ₹7,200 |
| 4.20 | 12.7 mm (1/2") dia | 8 | Mtr. | 850 ₹6,800 | 640 ₹5,120 | 950 ₹7,600 |
| 4.30 | 15.88 mm (5/8") dia | 16 | Mtr. | 900 ₹14,400 | 720 ₹11,520 | 1,000 ₹16,000 |
| 5.00 | Supply & drawing 1.1 KV Gr. 3 core 2.5 sq. mm. P.V.C. insulated copper cable for connecting the Power hub to ODU. (Make - Havells / Finolex / RR Kabel) | 10 | Mtr. | 100 ₹1,000 | 98 ₹980 | 120 ₹1,200 |
| 6.00 | Supply & drawing 1.1 KV Gr. 4 core 1.5 sq. mm. P.V.C. insulated copper cable for connecting the ODU TO IDU. (Make - Havells/ Finolex/ RR Kabel) | 10 | Mtr. | 120 ₹1,200 | 102 ₹1,020 | 150 ₹1,500 |
| 7.00 | Supply & laying 3/4" heavy type P.V.C. pipe for Water Drainage as per direction. | 20 | Mtr. | 100 ₹2,000 | 58 ₹1,160 | 80 ₹1,600 |
Tender Value
Refer Docs
EMD Value
₹3,022
Closing Date
8 Jan 2026, 11:55 amClosed
Assistant Engineer
OFFICE OF THE ASSISTANT ENGINEER Kalyani Electrical Sub-Division, PWD Kalyani, Nadia
Replacement of existing split AC at Doctors room of Cath Lab and Augmentation of AC at Server Room at Gandhi Memorial Hospital, Kalyani, Nadia.
2025_WBPWD_967806_1
WBPWD/AE/e-NIT- 06/KLY(3rd call) of 2025-26
Open Tender
ELECTRICAL WORKS ORG
7 days
Gandhi Memorial Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,022
OFFICE OF THE ASSISTANT ENGINEER Kalyani Electrica
10 Mar 2026
4 Dec 2025
13 Jan 2026
4 Dec 2025
13 Jan 2026
9 Dec 2025
8 Dec 2025
Amount
Supply & delivery 1.5 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 18000 BTU/hr. with 1 no. rotary compressor, 1 no. IDU of rated power supply - 230 V - 1 ph - 50 Hz. , 1 no. ODU of rated power supply - 230 V -1 ph - 50 Hz Air-flow/per IDU:- 650 CFM., Refrigerant: R-410A ( Make: Hitachi/Mitsubishi Electric).
Supply & delivery 2 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1 no. rotary compressor, 1 no. IDU of rated power supply - 230 V - 1 ph - 50 Hz., 1 no. ODU of rated power supply - 220 V - 1 ph - 50 Hz. Air-flow/per IDU:- 800 CFM., Refrigerant: R-410A ( Make: Hitachi/Mitsubishi Electric).
Installation, testing and commissioning of 1.5/1.8/2.0 Tr. split AC Machine with IDU&ODU including supply & fixing of 40 mm x 40 mm x 5 mm MS angle iron brackets (powder coated) with necessary nut- bolt etc. & mending good the damages.
Supply & laying of the following sizes Refrigerant Copper Pipe (Minimum thickness 0.9 mm and Make - Royku / Totaline / Mandeep) with insulation by nitril rubber of minimum thickness 9 mm [Make Aroflex / Acoflex] also raping the insulation & Copper wire with GKB Gold non-adhesive tape.
6.35 mm (1/4") dia
12.7 mm (1/2") dia
15.88 mm (5/8") dia
Supply & drawing 1.1 KV Gr. 3 core 2.5 sq. mm. P.V.C. insulated copper cable for connecting the Power hub to ODU. (Make - Havells / Finolex / RR Kabel)
Supply & drawing 1.1 KV Gr. 4 core 1.5 sq. mm. P.V.C. insulated copper cable for connecting the ODU TO IDU. (Make - Havells/ Finolex/ RR Kabel)
Supply & laying 3/4" heavy type P.V.C. pipe for Water Drainage as per direction.
Dismantling of existing damaged 1.5T/2T AC Machine from its position and handed over to authority.
Supplying and fixing Al. powder coated continuous grill.
Charges for lifting of Indoor & Outdoor units & Scaffolding Arrangement.
FREEZER (BID ID -7813162)
REFRICON (BID ID -7806429)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid