| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC Accepted for acceptance being lowest. | |
| 2 | L2₹29.5 L+₹1.3 L (4.58%)Rejected-Finance | L2 | Rejected-Finance Not L1. | |
| 3 | L3₹30.0 L+₹1.8 L (6.38%)Rejected-Finance | L3 | Rejected-Finance Not L1. | |
| 4 | L4₹33.6 L+₹5.4 L (19.0%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L4 | Rejected-Finance Not L1. | |
| 5 | L5₹36.5 L+₹8.3 L (29.4%)Rejected-Finance 108 MARUTI COMPLEX NEAR DIGVIJAY TIN FACTORY MILE STONE BUILDING KV ROAD JAMNAGAR 361001 | JAMNAGAR | JAMNAGAR | GUJARAT | 361001 | L5 | Rejected-Finance Not L1. |
Tender Value
₹27.5 L
EMD Value
₹55,000
Closing Date
2 Apr 2022, 6:00 pmClosed
GE (AF) Jamnagar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
REPAIR / MAINTENANCE OF AIR CONDITIONING PLANT AND UNSV SUMMER APPLIANCES SUCH AS AIR CONDITIONER, REFRIGERATION, WATER COOLER AND DEEP FREEZER ALONG WITH CERTAIN OTHER CONNECTED WORK AT AF-I AND AF-II UNDER GE (AF) JAMNAGAR NO.2
2022_MES_504203_2
8337/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No.2
₹55,000
Yes
7 May 2022
12 Mar 2022
4 Apr 2022
12 Mar 2022
2 Apr 2022
19 Mar 2022
Amount
M & L for annual servicing of Split Air conditioner cap 1.5/2.0 ton by disconnecting electric connection from its stabilizer or its electric board and remove the front cover of indoor AC unit and cleaning it with pressurized water and nylon brush, refixing the front cover of indoor unit. Remove the outer cover of outdoor unit and cover the condensing unit with ploythene/plastic cover so that water shall not be entered in the motor while cleaning the unit and filter with pressurized water then apply one coat of descaling solution and clean with wire mesh bursh/nylon brush to the condensing coil of out door unit and greasing of all moving parts. Cleaning of Cooling and condenser coil of indoor and outdoor unit shall be properly carried out without damaging other parts. Checking and making serviceable electrical connection of DBs, Stabilizer, wiring of ACs as per site condition and tightening all electrical connection complete all as specified and directed. Note: Replacement of defective parts with new parts shall be measured and paid seperately under respective items in the schedule.
M & L for Leak testing of cooling coils attached with indoor and outdoor unit of split air conditioner using CO2/Nitrogen gas, arrest of leakage with brazing of copper pipe and retest again for leakage complete all as specified and directed.
M & L for charging of refrigerant R-22/R32 gas to air conditioner or as per existing / manufacturer instructions suitable for split air conditioner cap 1.5 ton after flushing out the entire refrigerant, vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above complete all as specified and directed.
M & L for charging of refrigerant R-22/R32 gas to air conditioner or as per existing / manufacturer instructions suitable for split air conditioner cap 2.0 ton after flushing out the entire refrigerant, vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above complete all as specified and directed.
M & L for maintenance of air conditioner 1.5/2.0 ton capacity, Split type unit with replacement of old/unsv spare parts mentioned as under or as per manufacturer instructions including testing on load complete all as specified and directed.
S & F in repair over load protector suitable range and capacity
S & F in repair Starting capacitor 80/100/120 mfd suitable for 240 volts 50 HZ AC supply
S & F in repair Running capacitor of 36/45/50/60 + 5/6 mfd suitable for 240 volts 50 HZ AC Supply
S & F in repair capacitor of 2.5 mfd suitable for blower fan motor of 1.5/2.0 ton AC
S & F in repair thermostat switch suitable for 1.5/2.0 ton AC
S & F in repair Compressor relay suitable for 1.5/2.0 ton AC
S & F in repair Control relay suitable for 1.5/2.0 ton AC
S & F in repairs brass service valve of size 5/8" suitable for Split AC
S & F in repairs brass service valve of size 3/8" suitable for Split AC
S & F in repairs copper tubing of size 3/8" suitable for split AC with nitrile self adheive foam wrapped with PVC insulation all around the pipe line complete
S & F in repairs copper tubing of size 5/8" suitable for split AC with nitrile self adheive foam wrapped with PVC insulation all around the pipe line complete
Supply and fix in repair flexible PVC pipe for condense water outlet as per existing all as directed & as site requirement.
S & F in repairs copper condenser coil suitable for split AC of cap 1.5/2.0 ton complete with necessary electrical connection
S & F in repairs evaporator copper cooling coil suitable for indoor unit split AC of cap 1.5/2.0 ton complete with necessary electrical connection
S & F in repairs Blower motor of 1/7 HP to 1/6 HP 230 volts 930 RPM, 20 Watt, 3 speed for indoor unit of split AC 1.5/2.0 TR of existing make complete all as specified and directed.
S & F in repairs condenser fan motor 1/8 to 1/12 HP, 900/1400 RPM, 60 Watt suitable for 1.5/2 TR split AC outdoor unit, single phase, of existing make complete all as specified and directed.
S & F in repairs Codenser Fan motor for outdoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make complete all as specified and directed.
S & F in repairs Blower motor for indoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make complete all as specified and directed.
S & F in repairs Blade set of fan motor of out door unit, made out of Aluminium sheet Suitable for shaft dia 1/2" and fan dia 16"/ 18" in existing air conditioner split type complete all as specified and directed.
S & F in repairs Blade set of fan motor of out door unit, made out of PVC Suitable for shaft dia 1/2" and fan dia 16"/ 18" in existing air conditioner split type complete all as specified and directed.
S & F in repairs Pre-air filter made up of PVC for indoor unit of split AC suitable for any make and description complete all as specified and directed.
S & F in repairs PVC fan blower assembly for 1.5/2TR split AC's complete all as specified and directed.
S & F in repairs Printed circuit board(PCB) with suitable for Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection.
S & F in repairs Printed circuit board(PCB) with hand set of indoor, outdoor and display unit suitable for Inverter type Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection.
S & F in repairs Swing motor suitable for indoor unit of split AC suitable for any make and description complete all as specified and directed.
M & L for repairs to internal remote assembly cordless type suitable for split air conditioner with replacement of PCB, LED indicator and other micro components complete all as specified and directed.
M & L for replacement of defective cut open compressor/Uncut compressor suitable for air conditioner with new compressor filled with capila D and charging of refrigerant gas up to required capacity after flushing the complete refrigerant system including repair to leakage if any in refrigerant piping and replacement of filter complete for split type AC's of the following capacity complete all as specified and directed.
1.5 ton capacity
2.0 ton capacity
S & F in repair air conditioner outdoor unit single phase as per existing brand complete with all connection and taking out old unsv for the following cap of air conditioner. Make : Samsung/Voltas/Carrier/LG/O General
1.5 ton capacity
2.0 ton capacity
S & F in repair air conditioner indoor unit single phase as per existing brand complete with all connection and taking out old unsv for the following cap of air conditioner. Make : Samsung/Voltas/Carrier/LG/O General
1.5 ton capacity
2.0 ton capacity
Taking down / Dismantling carefully the indoor and outdoor unit of Split AC of capacity 1.5 TR / 2.0 TR with outdoor stand, plate for indoor unit and connected wiring, Transportation of complete set from old location to new location, refixing of same AC at new location complete all as specified and directed & detail as under:- (a) Fixing of indoor unit wall mounting type (to be installed inside the room) complete with, draining out arrangement for condensed water, fixing of inter connection pipe, all as directed. Fixing of cooling unit on wall shall be as per standard recommendation practice of manufacturers. (b) Erection of condenser, compressor unit on outside of the building, fixed over old clamp / bracket, all as per standard practice of manufacturer. (c) All civil work such as making hole in the wall for passing of pipe etc, to be done, as directed by Engr-in-Charge including making good disturbed surface. (d) concealing of refrigerant pipe with PVC flexible pipe. (e) Extention of pipe due to site condition if required shall be measured and paid separately under respective items taken before.
M & L for sub main wiring with 2 run single,core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including heavy duty PVC rigid conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified and directed. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment.
Supply and fix MCB’s single pole 6-32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting. Make: ABB/LEGRAND/HAVELLS/L & T
Supply and fix MCB’s triple pole, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting. Make: ABB/LEGRAND/HAVELLS/L & T
Supply and fix in repair metal clad single pole and earth enclosure with two pin and earth plugs and socket complete with one single pole MCB 20 Amps, 230 V, C type. Make: Legrand / Roma / ABB / HAVELLS / L&T
Comprehensive / Preventive maintenance including servicing of 18 TC capacity VRF based air conditioning system with connected indoor and outdoor units detail as under installed under GE (AF) Jamnagar No.2 for complete contract period detail as under all as specified and directed. Out door unit 18 HP capacity VRF unit of (Make -Blue Star, Model No - DVRF-18 TC Sr No-DVRF18TC14fooo64 Indoor unit :- 06 nos (Blue Star)
Comprehensive / Preventive maintenance of VRF based air conditioning shall be carried out as per manufacturer standard check list and detailed as under all as directed by Engineer-in-Charge. (a) Testing / Checking of compressor for its proper functioning and rectification of minor defect if any. (b) Testing / Checking of control switch such as pressure cut outs, water flow switch, temprature sensore for proper functiong. (c) Testing / Checking of PCBs of the Indoor unit & Outdoor unit for its proper functioning and rectification of minor defects if any. (e) Testing / Checking of Cooling coil for leakage and Rectification of leakage by brazing including cleaning of Cooling coil.
(f) Testing / Checking & servicing of blower fan motor and rectification of minor defect if any. (g) Testing / Checking of all electrical connection and control wiring tighting of electrical connection and rectification of minor defect if any complete. (h) Testing / Checking & servicing of condenser fan motor and rectification of minor defect if any. (j) Testing / Checking of condenser coil for leakage and Rectification of leakage by brezing including cleaning of condenser coil. (k) Testing / Checking of refrigerant pipe for leakage and Rectification of leakage by brazing including cleaning of refrigerant pipe. (l) Cleaning of entire indoor & outdoor unit for removing all dirt dust, grease etc
Note:- Rate for each job shall be deemed to be included. Comprehensive / Preventive maintenance including servicing of VRF unit two times during contract period. Contractor shall also be responsible to rectify any defect during break down without any extra cost during contract period.
(i) All defective speare parts & compressor etc if found unserviceable will be measured & paid separately as supply & fix in repair under respective items of This BOQ. (ii) Topping of refrigerant gas will be measured & paid separately. (iii) The rates quoted by the tenderer shall be deemed to include for any minor repair, which are obviously and fairly, intended which may not have been included in these documents, but which are essential for the execution and entire completion of works. The decision of the Accepting Officer as to what constitutes Minor details of the construction’ shall be final and binding. (iv) Comprehensive / Preventive maintenance including servicing of VRF unit, & repairing the VRF unit during breakdown / emergency shall be carried out through authorised representative of OEM. Contractor shall submit necessary documentary proof in support of the same.
All as per Item No 15 above 21 HP capacity VRF unit of Make -Blue Star, Model No - DVRF-21 TC Sr No-DLC34M15700836 with following indoor unit. Indoor unit : 08 Make blue star
All as per Item No 15 above but 12 HP capacity VRF unit of Make blue star, Model no - RXYQ10TRY69 with following indoor unit. Indoor unit : 06 nos Make blue star
Supply & Fixing in repair of inverter compressor suitable for 12 HP capacity VRF type AC unit (Make: blue star) with base frame & electrical Phase reversal protection comprising following JOB:- (i) Charging of nitrogen Gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure / leakage up to 72 Hrs after replacement of compressor & rectification of leakage if any. (ii) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure & rectification of leakage if any. (iii) Charging of complete system with R410 / R407 gas for maintaining the system pressure up to HP - 175 psi & LP - 65 psi. (iv) Measure the inlet and outdoor temperature of package unit. (v) Testing & commissioning of compressor after completion.
Supply & Fixing in repair of inverter compressor suitable for 10 HP capacity VRF type AC unit (Make Daikin, Model no - RXYQ10TRY69) with base frame & electrical Phase reversal protection comprising following JOB:- (i) Charging of nitrogen Gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure / leakage up to 72 Hrs after replacement of compressor & rectification of leakage if any. (ii) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure & rectification of leakage if any. (iii) Charging of complete system with R410 / R407 gas for maintaining the system pressure up to HP - 175 psi & LP - 65 psi. (iv) Measure the inlet and outdoor temperature of package unit. (v) Testing & commissioning of compressor after completion.
Material and labour for maintenance of VRF air conditioner of 12 / 10 HP capacity, VRF type unit with replacement of old/unsv spare parts mentioned as under or as per manufacturer instructions including testing on load complete all as specified and directed. Note: Make of VRF unit is Blue star & Daikin therefore spare part provided in the work shall be of make Blue star / Daikin, contractor may use spare part of other make as approved by the OEM.
Supply & Fix in repair main control PCB of indoor Unit of VRF type AC unit complete all as specified and directed.
Supply & Fix in repair power PCB for indoor unit of VRF AC complete all as specified and directed.
Supply & Fix in repair fan card for outdoor unit of VRF AC complete all as specified and directed.
Supply & Fix in repair pump to indoor unit of VRF AC unit complete all as specified and directed.
Supply & Fix in repair cassete controller to indoor unit of VRF AC complete all as specified and as directed.
Supply & Fix in repair ductable controller to indoor unit of VRF AC complete all as specified and directed.
Supply & Fix in repair hi-wall controller to indoor unit of VRF AC complete all as specified and directed.
Supply & Fix in repair motor to indoor unit of VRF AC complete all as specified and directed.
Supply & Fix in repair HP/LP sensor to indoor unit of VRF AC complete all as specified and directed.
Supply & Fix in repair sensors (Liquid, gas temp, room temp,supply temp) to indoor unit of VRF AC complete all as specified and directed.
Supply & Fix in repair Over Voltage PCB to outdoor unit of VRF AC complete all as specified and directed.
Supply & Fix in repair HP Switch to outdoor unit of VRF AC complete all as specified and directed.
Supply & Fix in repair motor to outdoor unit of VRF AC of any capacity complete all as specified and directed.
Supply & Fix in repair main board of outdoor unit VRF AC of any capacity complete all as specified and directed.
Supply & Fix in repair capacitor board of outdoor unit VRF AC of any capacity complete all as specified and directed.
Supply & Fix in repair inverter board of outdoor unit VRF AC of any capacity complete all as specified and directed.
Supply & Fix in repair bridge rectifier of outdoor unit VRF AC of any capacity complete all as specified and directed.
Supply & Fix in repair noise filter board of outdoor unit VRF AC of any capacity complete all as specified and directed.
Supply & Fix in repair sensors (Liquid temp HeX 1&2, Gas temp HeX1&2) of outdoor unit VRF AC of any capacity complete all as specified and directed.
Supply & Fix in repair Solenoid valve for outdoor unit of VRF AC of any capacity complete all as specified and directed.
Supply & Fix in repair Fan Blade of outdoor unit of VRF AC of any capacity complete all as specified and directed.
Supply and charging / topping up refrigerant gas R-410A to VRF type AC unit of any capacity complete all as specified and directed.
M & L for servicing / cleaning of water cooler of storage capacity / nominal cooling capacity (Ltrs/hr) 80/40 & 120/60 litres with the use of antiscaling agent for internal steel water tank, outer body and condenser coil of water cooler, Removal of dust and other deposited material for the various functional equipment using smooth nylon brush, cleaning of drainage for speedy water removal and checking of electrical connection to compressor and other electrically operated equipments, cleaning of fins and tubes of condenser, repair / replacement of PUF thermal insulation, checking of refrigerant leakage and functionality of water tap complete all as specified and directed.
M & L for charging of refrigerant R-12/134a gas to water cooler for the following capacities as per existing / manufacturer instrcutions after flushing out the entire refrigerant, vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions,as mentioned above complete all as specified and directed.
Storage capacity 80 ltrs and cooling capacity 40 ltrs
Storage capacity 120 ltrs and cooling capacity 60 ltrs
Material and labour for maintenance of water cooler with replacement of old/unsv spare parts as under including testing on load complete all as specified and directed.
S&F in repair Reciprocating type compressor suitable for water cooler type 40/80 litres Make: Emerson copland / carrier / Blue star / Teccumesh
S&F in repair Hermetic type compressor suitable for water cooler type 40/80 litres Make: Emerson copland / carrier / Blue star / Teccumesh
S & F in repair copper coiled condensor suitable for water cooler storage type of 40/80 or 80/120 Litres
S & F in repair Compressor relay suitable for water cooler storage type of 40/80 or 80/120Litres Make: Kilxen/KCL/Electrical
S & F in repair running capacitor 36/45/50/60 + 5/6 mfd suitable for water cooler storage type of 40/80 or 80/120 Litres
S & F in repair thermostat suitable for water cooler storage type of 40/80 or 80/120 Litres Make: Indfoss/Renutrol /Rockwell
Material and labour for Leak test with CO2/Nitrogen gas and arresting leakage with brazing of copper pipe complete all as specified.
Dismantling condenser fan motor of capacity 1/7 to 1/5 HP suitable for 40/80 and 80/120 Ltrs water cooler and Supply and fixing in repair of new fan and motor 75 to 90 watt, make and size and refixing in position, connecting and testing on load complete all as specified and directed. Make: AUE/ GE Motors/ ABB
M & L for carrying out repair / maintenance / servicing of Refrigerator of any capacity by periodic cleaning of internal and external parts, cleaning of water collection area and checking of electrical circuit repair / replacement of unserviceable / worn out spares and accessories to make the Refigerator in good working condition complete all as specified and directed Note: Defective spares required for replacement shall be measured and paid separately under respective items.
M & L for maintenance of Refrigerator any capacity with replacement of old/unsv spare parts as under including testing on load complete all as specified and directed.
S & F in repair condensor suitable for Refigerator of 195/ 250/ 300 ltr cap
S & F in repair cooling effect transmitting fan motor suitable for Refigerator of 195/ 250 / 300 ltr cap
S & F in repair timer with timer relay suitable for Refigerator of 195/250 / 300 ltr cap
S & F in repair Compressor Relay suitable for Refigerator of 195/250 / 300 ltr cap or as per existing Make : KCL/Rentrol/Indofos
S & F in repair thermostat suitable for Refigerator of 195/250 / 300 ltr cap Make: Indofos/Godrej/Annapurna
S & F in repair capillary with filter suitable for Refigerator of 195 / 250 / 300 ltr cap
S & F in repair Compressor suitable for Refigerator of 250 / 300 ltr cap or as per existing Make: Godrej / Teccumesh / Voltas / Whirpool / Kirloskar / copland
Material and labour for Leak test with CO2/Nitrogen gas and arresting leakage with brazing of copper pipe complete all as specified.
M & L for charging of refrigerant R-134a gas to Refrigerator for the following capacities as per existing /manufacturer instrcutions after flushing out the entire refrigerant, vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions,as mentioned above complete all as specified and directed.
Refrigerator cap 165/195 Ltrs
Refrigerator cap 230/250 Ltrs
Refrigerator cap 300/310 Ltrs
Material and labour for carrying out repair / maintenance / servicing of Deep freezer of any cap of freezer with periodic cleaning of compressor placement area, cleaning of water tube and checking of electrical circuit repair / replacement of unserviceable / worn out spares and accessories to make the Deep Freezer in good working condition complete all as specified and directed. Note: Defective spares required for replacement shall be measured and paid separately under respective items.
Supply and fix in repair Thermostat of suitable capacity as per existing Freezer 95 / 145 / 188 / 285 / 295 Ltrs
Supply and fix in repair Compressor relay of suitable capacity for Freezer 95 / 145 / 188 / 285 / 295 Ltrs
Supply and fix in repair condensor motor of suitable capacity for Freezer 95 / 145 / 188 / 285 / 295 Ltrs
Material and labour in repair for Condenser suitable for Deep freezer 95 / 145 / 188 / 285 / 295 Ltrs
Material and labour for Leak test with CO2/Nitrogen gas and arresting leakage with brazing of copper pipe complete all as specified.
M & L for charging of refrigerant R-134a / R-600a gas to deep freezer or as per existing / manufacturer instructions after flushing out the entire refrigerant, vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above complete all as specified and directed.
Material and labour for servicing/cleaning of water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr of any make, with the use of antiscaling agent for internal steel water tank, outer body and condenser coil of water cooler, Removal of dust and other deposited material for the various functional equipment using smooth nylon brush, cleaning of drainage for speedy water removal and checking of electrical connection to compressor and other electrically operated equipments, cleaning of fins and tubes of condenser, repair/replacement of PUF thermal insulation, checking of refrigerant leakage and functionality of water tap complete all as specified and directed.
M & L for charging of refrigerant R-12/134a gas to water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr of any make as per existing / manufacturer instrcutions after flushing out the entire refrigerant, vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above complete all as specified and directed.
Material and labour for maintenance of water dispenser with replacement of old/unsv spare parts as under including testing on load complete all as specified and directed.
Supply and fix in repair compressor, single phase, 230 V suitable for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr of any make.
S&F in repairs Copper Condenser coil suitable for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr along with necessary electrical connections etc. all as specified and directed.
S & F in repairs Compressor relay suitable for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr. Make: As per recommendation of OEM and approved by the GE.
S & F in repairs running capacitor suitable for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr. Make: As per recommendation of OEM and approved by the GE.
S & F in repairs thermostat suitable for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr. Make: As per recommendation of OEM and approved by the GE.
S & F in repairs heating element with tank for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr. Make: As per recommendation of OEM and approved by the GE.
Material and labour for Leak test with CO2/Nitrogen gas and arresting leakage with brazing of copper pipe complete all as specified.
Supply and Fix in repair voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation voltage as under and output voltage stabilized at 230Volts with accuracy of ± 2.5% for the following capacity including depositing of old stabilizer at MES store yard complete all as specified and directed.
12 Amp suitable for 1.5 ton air conditioner for input variation between 150V to 290V Make : V Guard Model No VND 400 digital or equivalent in Microtek/Bluebird
15 Amp suitable for 2.0 ton air conditioner for input variation between 130V to 300V Make : V Guard Model No VBG 500 or equivalent in Microtek/Bluebird
Supply and fix in repair three pole connector suitable for voltage stabilizer 4KVA/5KVA Capacity. Make: As per recommendation of OEM and approved by the GE.
Supply and Topping up refrigerant gas R-407A to the central / package AC plant of any capacity system all as specified and directed.
Supply, install, testing and commissioning of various accessories connected to uninsulated piping and valves for condenser water complete in respect of central AC Plant including taking out old unsv and repalcement of following items complete all as specified and directed.
75/80 mm dia Balancing Valve with cast iron body confirming to IS
75/80 mm dia Non return valve with cast iron body confirming to IS
Pressure Gauge (0-21Kg/cm2)
Thermometer
Supply, install, testing and commissioning of various accessories as under connected to insulated piping and valves for chilled water in respect of Central AC Plant including taking down old unsv and replacement of following items complete all as specified and directed. Note : The unit rate quoted shall include for necessary insulation material i.e. Nitrile rubber of suitabe thickness or as directed.
65 mm dia Butterfly Valve with cast iron body, seat of black nitrite rubber, nylon coated S.G. Iron disc, PTFE coated SS (AISI 410) shaft, companion flanges, nuts, bolts, gaskets etc, confirming to BS:5155 MSS SP.67 & API. 6098 and shall be designed to fit without gaskets between mating and seal in both direction. The valves shall be of integral moulded design. Make:- L&T, Leader, Zoloto, Upadhayay
75/80mm dia Butterfly Valve with cast iron body, seat of black nitrite rubber, nylon coated S.G. Iron disc, PTFE coated SS (AISI 410) shaft, companion flanges, nuts, bolts, gaskets etc, confirming to BS:5155 MSS SP.67 & API. 6098 and shall be designed to fit without gaskets between mating and seal in both direction. The valves shall be of integral moulded design. Make:- L&T, Leader, Zoloto, Upadhayay
M & L for cleaning of cooling tower Induced draft type cooling tower 50 TR capacity of FRP complete with all accessories, basin, fittings, fan, fan motor etc, using descaling material and removal of deposited material and carried out minor repair to cooling tower if required such as replacement of baffle plates, replacement of valve, drain plug and leakage to pipes etc, complete as per manufacturere's instructions all as specified and directed.
Supply and Topping up refrigerant gas R-407A to the central / package AC plant of any capacity system complete all as specified and directed.
S & F electrical insulated rubber mat of size 1m x 2m x 12mm thick confirming to IS:15652:2006 complete all as specified and directed.
M&L for repairing / servicing the Mono block pump for Chilled water cap 60 US GPM with Static Head 25 M by disconnecting the pump from motor, opening for inspection, replacing the worn out parts like gland bush, bearings, gland bolts and nuts, gland packing, gasket, water seal etc including repairing to pump shaft by remetalling, grinding, polishing and reassembling complete pump & refixing in same position & connecting including replacing the rusted nuts, bolts, washers etc and testing complete all as specified and directed.
M&L for repairing / servicing the Mono block pump for Condenser water cap 75 US GPM with Static Head 20 M by disconnecting the pump from motor, opening for inspection, replacing the worn out parts like gland bush, bearings, gland bolts and nuts, gland packing, gasket, water seal etc including repairing to pump shaft by remetalling, grinding, polishing and reassembling complete pump & refixing in same position & connecting including replacing the rusted nuts, bolts, washers etc and testing complete all as specified and directed.
Supply and fix in repair oil pressure cut out type MP-55 for compressor of central type AC plant of any capacity. Make : Indfoss / Danfoss / Honeywell
Jyoti Refrigeration
Chamunda Kruparefrigeration
SURESH ELECTRICALS
Rameshwar Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .