Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹3.9 Cr
EMD Value
₹3.9 L
Closing Date
16 Mar 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Dy. Municipal Commissioner ( East Zone) Ahmedabad Municipal Corporation
CONSTRUCTION OF U.H.C. BUILDING AT F.P. NO :- 33, DRAFT T.P.S. NO: 64 (GHODASAR-2) IN RAMOL WARD , EAST ZONE, AHMEDABAD
279682
EZ 29-1408/2025-26 UHC
Open
Miscellaneous Works
Works
Ahmedabad
3 documents required · 3 mandatory
₹6,000
Yes
Municipal Commissioner, Ahmedabad
₹3.9 L
Yes
23 Feb 2026
23 Feb 2026
23 Feb 2026
16 Mar 2026
23 Feb 2026
Name of Work : CONSTRUCTION OF U.H.C. BUILDING AT F.P. NO :- 33 , DRAFT T.P.S.
NO: 64 (GHODASAR-2) IN RAMOL WARD , EAST ZONE, AHMEDABAD
Bill of Quantities
Unit Rate Amount
Civil Work Estimate
1 Demolition & Dismantling work
Demolition of RCC work using Hydra
Breacker including stacking of servicable
a 8.00 materials and disposal of unservicable
materials with all lead and lift.Removal
Of Existing Building Foundation and
Super Structure If Any. 1047.38 Cu.M.
Demolition of Brick work and stone
masonry including stacking of
serviceable materials and disposal of
unserviceable materials with all lead and
lift.(ii) In Cement Mortar.Removal Of
Existing Building Foundation and Super
Structure If Any. 544.95 Cu.M.
Dismentaling of sheet roofing including
ridges, Hips, Valleys, Gutters etc.
c stacking of serviceable materials and
disposal of unserviceable materials with
all lead and lift.
i 5.00 (i) G.I.sheet roofing. 47.25 Sq.mt
ii 5.00 (ii) A.C. sheet roofing. 53.55 sq.mt
Dismentling steel work including
distempering and stacking the materials
with all lead and lift.
Dismentling doors, windows, ventilators
etc. (wood or steel) shutters including
e 2.00 chowkhats architraves, hold fasts and
other attachment etc. complete and
stacking them with in all lead and lift.
(i)Notexceeding 3 Sq.M. in area. 185.85 Each
Removing & Scrapping of Old
deteriorated Plaster of any thickness
f 250.00 from Masonary / R.C.C. member
including stacking of serviceable material
& disposal of un serviceable from site of
work with all lead & lift. 19.38 Sq.M.
Dismentaling any type tiled of stone
floors laid in mortar including stacking of
g 50.00 serviceable materilas and disposal of
unserviceable materials with all lead and
lift. 47.25 Sq.M.
2 Excavation for foundation including
sorting out stacking of useful material &
disposing of excavated stuff upto 50 mt.
lead. Loose & Soft soil.Excexuted With
Mechanical Effort
a 1131 up to 1.5 mt. depth 115.92 Cu.M.
b 1043 1.5 to 3.0 mt. depth. 128.52 Cu.M.
c 405 3.0 to 5.0 mt. depth 141.11 Cu.M.
d 500.00 Add extra for Disposing off the
excavated stuff of above items for lead of
e 500.00 Add extra for Disposing off the
excavated stuff of above items for lead of
Providing and installing cast in situ single
under reamed piles of specified diameter
and length below pile cap, excluding the
cost of Concrete, steel reinforcement but
including the cost of boring with
bentonite solution and the length of the
pile to be embedded in pile cap etc. all
complete. (Length of pile for payment
shall be measured upto to the bottom of
i 10.00 400 mm dia. Piles 644.63 Rmt.
ii 10.00 450 mm dia. Piles 705.03 Rmt.
g Extra over single under ream for
providing additional bulbs in under
reamed piles, under specified diameter
excluding the cost of Concrete, steel
reinforcement (only the nos. of extra
bulbs are to be paid).
t 1.00 400 mm dia. Piles 813.05 Each
ii 1.00 450 mm dia. Piles 1103.43 Each
3a 1 Provdg. & laying cement concrete 1:5:10
(1 cement : 5 course sand : 10 hand
broken aggregates 40 mm nominal size)
and curing complete, excluding cost of
form work in foundation & Plinth.
3b Provdg. & laying cement concrete 1:3:6
(1 cement : 3 coarse sand : 6 hand
broken stone aggregates 40 mm nominal
size) and curing complete excluding cost
of form work in
232.00 (A) Foundation and plinth 2976 Cu.M.
3c 95 Supplying of graded hand brocken stone
size of 90 mm to 127 mm at site (Rubble
3d 415 Labour charges for spreading the spouls
90 mm to 127 mm thick layer good earth
filling in voids correcting the grade &
camber comp. with rolling, watering, incl.
preparing thesurface by brushing for
removing all loose or dirts ect.comp.
4 2.00 Provdg. & laying cement concrete 1:4:8
(1 cement : 4 coarse sand : 8 hand
broken stone aggregates 40 mm nominal
size) and curing complete excluding cost
of form work in foundation& plinth.
5 2100 Filling available excavated earth
(excluding rock) in trenches, plinth, sides
of foundations etc. in layers not
exceeding 20 cm. in depth consolidation
each deposited layer by ramming and
6 Conveyance charges of earth lime,
murrum, building rubbish, manure,
garbage, sludge, excavated rock, fly ash,
aggregate of any kind etc. comp.
a 50.00 Conveyance charges upto 1 km 46.63 Cmt
b 50.00 Conveyance charges upto 2 km 60.69 Cmt
c 3200.00 Conveyance charges upto 5 km 100.44 Cmt
d 3200.00 Extra For Lead on Above Item Above
km & upto 6 km 9.26 Cmt
e 3200.00 Extra For Lead on Above Item Above
km & upto 7 km 9.26 Cmt
f 3200.00 Extra For Lead on Above Item Above
km & upto 8 km 9.26 Cmt
g 3200.00 Extra For Lead on Above Item Above
km & upto 9 km 9.26 Cmt
h 3200.00 Extra For Lead on Above Item Above
7a 10 Filling in plinth with sand under floors
including watering, ramming,
consolidating, compacting and dressing
etc. completed.
7b 225.00 Filling in foundation and plinth with
murrum or selected soil in layers of
cm. thickness including watering,
ramming and consolidating etc.
8 Brick work using common burnt clay
building bricks having crushing strength
not less than 35 kg/Sq. cm. in cement
mortar 1:6 (1 cement : 6 fine sand)
conventional brick
a 110 (a) in foundation & Plinth 3981.21 Cu.M.
b 217.00 Super structure Upto Floor Two Level
c 156.00 Super structure Above Floor Two Level
9 I.Half brick masonry in common burnt
clay building bricks having crushing
strength note less than 35 Kg/Sq. Cm. in
cement mortar 1:4 (1 cement : 4 coarse
sand) using conventional brick in Super
structure upto floor Four level
a 113.00 All Floor Level 646.7 Sq.M.
10.1 Providing and laying controlled cement
concrete of M-25 Grade and curing
complete, Excluding the cost of form
work, Scaffolding, cost of reinforcement
for reinforced concrete work For any
Height up to any FloorLevel.
a Foundations,Raft,Footings,Mass
50.00 concrete 4238.04 Cu.M.
b1 35.00 RCC Retaining wall at All Floor 4519.88 Cu.M.
c1 Tie-Beam, Lintel , Beam- Bracket, Stair
Case & Landing, Coping ,Slab, balcony,
weather shed, loft , any cantilever etc All
24.00 Floor 4496.07 Cu.M.
d1 Columns,Pillars, posts and struts at All
5.00 Floor 4593.91 Cu.M.
10.2 Providing and laying controlled cement
concrete of M-20 Grade and curing
complete, Excluding the cost of form
work, Scaffolding, cost of reinforcement
for reinforced concrete work For any
Height up to Floor Four Level.
a 3.00 Foundations,Raft,Footings,Mass
concrete 3977.88 Cu.M.
b1 47.00 Tie Beam , Lintel , Beam- Bracket
Coping ,landing, Slab, balcony, weather
shed, loft , any cantilever etc at All Floor 4460.36 Cu.M.
c1 3.00 Column at All Floor 4558.2 Cu.M.
d1 1.00 Stair Case All Floor 5418.91 Cu.M.
Providing and laying in position Ready
Mixed M250 grade concrete for
reinforced cement conctere work , using
cement content as per approved Design
Mix manufactured in fully automatic
batching plant and transported to site of
work in transit mixer for all lead having
continuous agitated mixer, manufactured
as per mix design of specified grade for
reinforced cement concrete work
including pumping of R.M.C. from transit
mixer to site of laying with all lead and
lift, excluding the cost of centering
shuttering finishing and reinforcement
including cost of admixtures in
recommended proportions as per IS:
9103 to accelerate/ retard setting of
concrete, improve workability without
impairing strength and durability as per
direction of the Engineer - in charge.
Without Fly Ash (Min cement level as per
latest IS 456 shall be maintained)
(Cement level 450 kg )
Providing and laying in position Ready
Mixed M200 grade concrete for
reinforced cement conctere work , using
cement content as per approved Design
Mix manufactured in fully automatic
batching plant and transported to site of
work in transit mixer for all lead having
continuous agitated mixer, manufactured
as per mix design of specified grade for
reinforced cement concrete work
including pumping of R.M.C. from transit
mixer to site of laying with all lead and
lift, excluding the cost of centering
shuttering finishing and reinforcement
including cost of admixtures in
recommended proportions as per IS:
9103 to accelerate/ retard setting of
concrete, improve workability without
impairing strength and durability as per
direction of the Engineer - in charge.
Without Fly Ash (Min cement level as per
latest IS 456 shall be maintained)
(Cement level 400 kg )
Drilling suitable holes in reinforced or
plain cement concrete with power driven
drill machine to a minimum depth of
80mm upto 250mm in RCC beams,
lintels, columns and slabs to introduce
steel bars for sunshades/balconies
including fixing the steel bars in position
using Hilti Chemical HY200-R but
excluding the cost of reinforcement, all
complete as per direction of Engineer-In-
a 75.00 8 mm Dia in 80 mm Deep & 12 mm Dia
Drilling 183.52 Each
b 500.00 10 mm Dia in 100 mm Deep & 14 mm
Dia Drilling 263.66 Each
c 500.00 12 mm Dia in 120 mm Deep & 16 mm
Dia Drilling 343.80 Each
d 40.00 16 mm Dia in 160 mm Deep & 20 mm
Dia Drilling 608.63 Each
e 5.00 20 mm Dia in 200 mm Deep & 25 mm
Dia Drilling 1024.44 Each
f 5.00 25 mm Dia in 250 mm Deep & 32 mm
Dia Drilling 1938.54 Each
11 Providing and laying controlled cement
concrete 1:2:4( 1cement : 2 coarse sand
: 4 Graded stone aggregate 20 mm
nominal size ) and curing complete,
Excluding the cost of form work and
reinforcement for reinforced concrete
a 1.00 Foundations, footings, base of
columns,grade slab and mass concrete. 3923.53 Cu.M.
b 1 slab, landing shelves, Balconies, lintels,
beams, girders, and cantilever, up to
aany floor level. 4012.47 Cu.M.
505.00 P/A Trimix with dewatering machine and
floater machine on constructed R.C.C.
c work incl. cost of machine and labour
etc. comp. as directed.
d 150.00 Making 15 mm Groove in R.C.C work on
road and filling it with poly sulfied selant
and finished it good incl. all labour
charges etc. comp. as directed
26.00 Providing and laying and fixing 25 mm
thick expansion joint by hydrocell semi
rigid UV resistance with high
e performance laminated closed cell
polythene foam joint filler in sheet foam
as directed, etc. complete.
12 Providing form work in ordinary timber
planking so as to give a rough finish
including centering, shuttering, strutting
and propping etc. height of propping and
centering below supporting floor to
celling not exceeding 4 M & removal of
the same for in situ reinforced or plain
concrete work in
a 474.00 (A) Foundation, footings, bases of
columns etc. and mass concrete. 171.68 Smt
b 1055.00 (B) Flat surface such as soffits of slabs,
landing and the like 252 Smt
c 618.00 (C) Vertical surfaces such as walls (any
thickness) partitions. 229.95 Smt
(D) Columns, pillars, posts & struts.
d 1577.00 (1) Square, rectangular, polygonal in
plan 297.68 Smt
e 10.00 (2) Circular or curved in plan. 422.1 Smt
f 1636.00 (H) (1) Sides and soffits of beam,
haunchings cantilevers, girders,
bressumers, Coping and lintels not
exceeding 1 M in depth.
g 10.00 (2) Sides and soffits of beam,
haunchings cantilevers, girders,
bressumers and lintels exceeding 1 M in
h 48.00 (L) chullah hoops, weather sheds,
chhajas, carbels etc including edges. 155.78 Smt
i 90.00 (M) Staircase with-sloping or stepped
soffits incl. risers & strings excluding
landing. 242.55 Smt
j 60.00 Extra for additional height of propping
and centering where the height of
propping and centering exceeds 4 .O M
between supporting floor to ceiling
including temporary brick or stone pillars
for supporting as required. (i)Height
more than 4.0 M.and upto 5.0 M.
13 Providing T.M.T Fe 500D bar
reinforcement for R.C.C. work including
bending, binding and placing in position
complete up to any floor level..
a 100650.0 All Floor Level 75.46 Kg.
14 35.00 Providing and laying polished Kota stone
slab (Polished / River Finish, Green
colour ) flooring over 20 mm. (average)
thick base of cement mortar 1:6 (1
cement : 6 coarse sand) or lime mortar
1:1.5 laid over and joined with grey
cement slurry including rubbing and
polishing complete.25 mm th.
15 70.00 Providing and laying polished Kota stone
slab 25 mm. thick in Platform ,Riser of
Stair , Skirting, Tread , dado and pillars
laid on 10 mm. thick cement mortar 1:3
(1 cement : 3 coarse sand) jointed with
grey cement slurry including rubbing and
polishing and MAking groove where it is
Required etc. compl
16 5.00 Providing and laying white/Colur glazed
tiles 6 mm thick in flooring treads of
steps and landing laid on a bed of
mm thick cement mortar 1:3 (1 cement :
3 coarse sand) finished with flush
pointing in white cement.
17 512.00 Providing and layingWhite / Colour
glazed tiles of size 600 mmx300mm x
mm / 300 mmx 450mm x 8 mm in
skirting, risers of steps, Floor and dedo
on 10 mm. thick cement plaster 1:3 (1
cement : 3 coarse sand) and jointed with
white cement slurry.
18 2.00 Providing and laying marble stone slab
flooring over 20 mm. (Average) base of
cement mortar 1:6 (1 cement: 6 coarse
sand) or L.M. 1:1.5 laid and jointed with
grey cement slurry including rubbing and
polishing complete: (A) Marble slab
19 980.0 Providing and laying Vitrified tiles 8 to
mm thick , 24'' x 24'' in flooring treads of
steps and landing laid on a bed of 12mm
thick cement mortar 1:3 (1-cement : 3-
coarse sand) finishing with flush pointing
in white cement.
19b 1230.0 Providing and laying Vitrified tiles 8 to
mm thick , 24'' x 24'' in skrting risers of
steps and dedo on 10mm thick cement
plaster 1:3 (1cement : 3-coarse sand)
and jointed with white cement slurry
20 95.0 Providing and laying Ceramics tiles 6 to
8 mm thick in flooring, treads of steps,
landing and dedo on 12 mm. thick
cement plaster 1:3 (1 cement : 3 coarse
sand) and jointed with white cement
21 600.00 Providing & Laying 18 mm thick Mirror
polish granite For flooring , counter , stair
riser , tread , skirting , dedo , Jambs
Seating etc. machine cut or chiselled on
bed of cement mortar 1:1 pointing with
neat cement slurry incl. moulding,
Making grooves where it is required etc.
comp. as per instruction of engineer in
charge. 2385.71 Sq. M.
22a Provdg. 20 mm. thick Finish / Mala
cement plaster in single coat on fair side
of brick / concrete walls for interior
plastering upto any Floor level and
finished even and smooth in C.M.1:4.
i 1393.00 All Floor Level 190.58 Sq.M.
b Provdg. 20 mm. thick Finish / Mala
cement plaster in single coat plastering
on ceilings, Beam side and sofits of
stairs upto any Floor level and finished
even and smooth in C.M.1:4.
i 1180.00 All Floor Level 215.15 Sq.M.
c 253.00 Providing & fixing 23 cm wide chicken
mesh jali with nails & then application of
15 mm plaster on R.C.C. & masonary
joints as per dir. of engg. In charge.
d 170.00 Providing and mixing water proofing
materials in cement mortar in proportion
recommended by the manufacturer. etc.
comp. as per instruction of engineer in Per Bag
charge. of 50 Kg
23a 1391.00 Providing 20 mm th. Double coat Sand
face / Mala Cement Plaster on Walls
upto any Height Above Ground level
consisting of 12 mm th. Backing coat of
C.M. 1:3 ( 1 cement : 3 Ssand ) & 8 mm
th. Finishing coat of C.M. 1:1 ( 1 cement
: 1 sand ) ets. Complete.
24a 20.00 White / Color washing with lime on
undecorated wall surfaces (two coats) to
give an even shade including thoroughly
brooming the surface to remove all dirt,
dust mortar drops and other foreign
24b 1125.00 Providing & Applying 3 mm thick
External Wall Rustic Type Texture as
per Design & Make as Approved by
Consultants / Engineer in Charge. Work
Includes All Necessary Scaffolding Work
upto Any Height.
24 c 1391.00 Finishing walls with Acrylic Smooth
exterior paint of required shade :New
work (Two or more coat applied @
ltr/10 sqm over and including priming
coat of exterior primer applied @
24d 10.00 P./L. METALIC HERITAGE SURFACE
Providing and fixing of HERITAGE
textured homogeneous wall finishing
system from BAKELITE HYLAM LTD or
equivalent make consisting of a two
component system of (25 kgs per Pack)
made of 92% silica particles coated with
fade resistant pigments, 100% acrylic
polymer bonding agent (5kgs per pack)
with the applied thickness of the coating
being between 0.8mm-1.2mm to be
applied on acured, smooth level plaster
without keying, as per the
shades/combinations approved, as per
the manufacturer directions, for usages,
tobe applied by an approved applicator
of the manufacturer, as per the directions
/ supervision of the engineers in charge,
all complete. Includes All Necessary
Scaffolding Work upto Any Height.
24e 9.00 Painting the illustration circle of Diameter
44 inch with weather proof exterior
emulsion acrylic based paint as per
defined shade code by experienced
applicator of standard drawing and
design according to the reference
manual of Facade Branding for Health &
Wellness Centres of Ayushman Bharat
Scheme as per the direction of the
Engineer in Charge.
25a 2580.00 Wall Painting (two coats) with plastic
emulsion / Oil paint of approved brand
and manufacture and of shade required
on undecorated wall surfaces to give an
even shade, over and including a priming
coat with alkali resistance primer of
approved brand and manufacture after
thoroughly brushing the surface free
from mortar droppings, and other foreign
matter and also including preparing the
surface even and sand -papered smooth
b 2580.00 Extra over above item for every
subsequent coat of of wall painting with
plastic emulsion / Oil paint of approved
c 2580.00 Applying two coats of Birla (white cement
based) or Asian (acrylic lapy-putty) or
equivalent & two coats of primer of
approved brand and manufacture on
new wall surface to give an even shade
including thoroughly brushing the surface
free from mortar dropping and other
foreign matter and sand papered
26 Providing and supplying ISI marked only
standard length Stonewate pipes in standard
lengths of following class and diameter
including all taxes,insurance, transportiton,
fright charges, octroi,inspection charges,
loading,unloading, conveyance to
departmental stores, stacking etc. complete
a 70.00 23 cm dia. 299 Rmt
Lowering, laying and jointing stone ware
pipes of following diameters with cement
joints in C.M.1:1 proportion in proper position
, grade and alignment at all level as directed
by Engineer-in- charge including conveyance
from stone to site of work, Jointing material
b 70.00 23 cm dia. 128 Rmt
Providing & Laying & Jointing glazed
stoneware pipes incl. excavation up to
2.0 mt.,refilling, trasporting the pipe to
work site, unloading, lowering in
trenches, laying and jointing the pipes in
c.m. 1:1 incl. all jointing materials such
as cement, sand, hemp, bitumen as dire.
testing the pipe line to a head of 1.5 mt.
and hydraulic test as dire incl. watering
trenches, spreading , and carting away
of surplus earth within 100 mt.lead as
dire. etc. comp.
b 15.00 10 cm dia 288.23 Rmt
c 15.00 15 cm dia. 211.05 Rmt
27 8.00 Constructing brick masonry chamber for
under ground C.I. Inspection chamber
and bends with bricks having croshing
strength not less than 35 Kg. Cm2 in
C.M. 1:5 C.I. cover with frame (Lightduty)
455mm x 610 mm intenal dimensions
total weight of cover with frame to be not
less than 38 Kg. (Wt. of cover 23Kg.)
and Wt. of frame 15Kg.) (R.C.C.top slab
with 1:2:4 mix (1-cement:2-coarse
sand:4-graded stone aggregate 20mm
size) foundation concrete 1:5:10 inside
plaster 15 mm thick with cement mortar
1:3 finished smooth with a floating coat
of neat cement on walls and bed
concrete etc. complete.(i) Inside
dimensions 455 mm x 610 mm and up to
28 a 3.00 Constructing Manhole with R.C.C. top
slab in 1:2:4mix (1-cement: 2-coarse
sand:4-graded stone aggregate 20 mm
nominal size) foundation concrete 1:3:6
mix (1-cement:3-coarse sand:6-Brick
bats 40+50mm size) inside plastering
15mm thick with Cement Mortar 1:5 (1-
Cement:5-coarse sand) finished with a
floating coat of neat cement and making
channels in cement concrete 1:2:4 mix
(1-Cement:2 -Coarse sand:4-stone
aggregate 20 mm nominal size) finished
smooth complete including curing and
festing (i) Inside size 900mm x 1200mm
and up to 1.5M. deep including C.I. cover
with frame size 560 mm diameter total
weight of cover and frame to be not less
than 128kgs. (Wt. of cover 64Kg. and
Wt. of frame 64Kg.) (A) With 230 mm
thick walls of brick masonry using brick
having crushing strength not less than
35Kg./Sq.cm. in Cement Mortar 1:5 (1-
Cement: 5-Coarse sand) (2)B type depth
up to 1.50 Metre
Providing and fixing white vitreous china flat
back or wall corner type lipped front urinal
basin of 340x280x470 mm sizes
respectively with standard flush pipe, Waster
Pipe, Waste Coupling, PVc Connection and
G.I clamps complete, including painting of
fittings and brackets, cutting and making
good the walls and floors wherever required :
Cera Model No. S4020103 or Equivalent 3344.35 No.
b 15.00 Providing and Fixing of C.P. Brass BIB
Cock of 15 mm Dia of Jaquar make
florentine series model no. 5047n or
equivalent make with all necessary
fittings. as approved by Engineer - in -
c 25.00 Providing and fixing brass screw down
Angle stop tap.(A) 15mm dia. Of Jaquar
make florentine series modelno. 5053n
or equivalent make with all necessary
fittings. as approved by Engineer - in -
d 2.00 Providing and fixing C.P. brass shower
rose with 15mm or 20mm inlet Shower
Arm.(A) 100mm dia. Each
Provding and Fixing of autoclosing
pressmatic pillar cock / bib cock with all
necessary fittings of Polished Bright
Chrome Finish of Jaquar make model
no. 031L65 or equivalent make as
approved by Engineer in Charge. Rate
including of cost of labour, material etc.
in complete manner. 3280.52 No.
Providing and Fixing of C.P. Brass Two
Way Bib Cock of 15 mm Dia of Jaquar
make model no. 041kn or equivalent
make approved make with all necessary
fittings. as approved by Engineer - in -
charge., 1411.58 No.
Providing and Fixing of C.P. Brass urinal
Valve Auto Closing System With Full
Built in Control Cock & Wall Flange of
mm Dia of Jaquar make model no.
or equivalent make approved make with
all necessary fittings. as approved by
Engineer - in - charge., 2568.08 No.
Providing and Fixing of C.P. Brass Pillar
Cock Auto Closing System with Elbow
Operated Extended Lever of 15 mm Dia
of Jaquar Make Model No,031 MED or
Equvalent Make with all necessary
fittings. as approved by Engineer - in -
charge., 3723.48 No.
30 11.00 Provdg. & laying S.W. Gully trap with C.I.
garting brick masonry chamber & water
tight C.I. cover with frame of 300 mm x
300 mm size ( inside) with standard
weight. sqare mouth trap size 150 x100
31 2000.00 Providing erecting and fixing double
coated ISI water tank of required
capacity each with all necessary fittings
and connection etc. complete on terrace
32 20.00 Extra rate over item of excavation of
earth for excavation of asphalt
pavement/RCC of thickness up to
meter including demolishing the asphalt
carpet, metal, soiling / cutting
Reinforcement etc.comp. with stacking
the material as directed.-up to
meter thickness
33 28.00 P/F PVC / C.I. (span) nahni trap and all
of the following nominal dia of self
cleanising design with C.I.Screw down or
hinged greeting inclusive cost of cutting
and making good the walls and floors for
drain 75 mm dia. etc. comp.
34a Provdg. And fixing to wall, ceiling & floor
in true line and level UPVC pipe
Schedule- 40 of make as approved by
engg. incharge. pipe shall be fix on wall
with the help of clamp at every twi meter
center to center of shall be concealed as
directed in cluding neccesarry fitting etc.
in cluding testing of pipe and jointd and
fixing the same with adhesive solvent
including cost of all materials of
following nominal bore
iii 10.00 32 mm 117.97 Rmt
34b Providing and fixing concealed center
point to wall ceiling & floor CPVC (SDR
13.5) PIPE having National Sanitation
Foundation (NSF) seal for potable water
of following dia. nominal bore tube
fittings and clamps including making
good the wall, ceiling and floor etc.
iii 10.00 25 mm 247.25 Rmt
35 Provdg. And fixing to wall ,ceiling and
floor 10.00 kg. F/Sq.Cm2 working
pressure polythelene pipes of the
following outside diameter, low, density,
complete with special flange
compression type fittings, wall clips etc.
making good wall ceiling and floor.
b 45.00 75mm dia 274.68 Rmt
c 125.00 110 mm dia 332.91 Rmt
36 4.00 Providing and fixing water closet
squatting Pan ( Indian type W.C. Pan)
size 580mm (A)VitreousChina. (I)Long
pattern = White colour with Trap and Pair
37a 7.00 Providing and fixing white vitreous china
extended wall mounting water closet of
Cera Make S1043101 Carat Model Or
Equivalent Model With EWC Soft Close
Seat Cover, Chair Bracket, nuts, bolts
and gasket etc complete.
b 11.00 Providing and Fixing of C.P. Brass Flush
Cock of 25 mm Dia of Jaquar make model
no. 081 or equivalent and Outer Body of
Jaquar make model no. 5083KPM or
equivalent approved make with all necessary
fittings. as approved by Engineer - in -
c 7.00 Providing and fixing Health Faucet of Jaquar
make model no. 573 oe equivalent make as
approved by engg. In charge with flexible
tube upto 1 metre long etc. complete. 1543.36 No.
38a 2.00 Providing and fixing 24"x18"x8" Carysil
Elegance or Equivalent Make of Single Bowl
Sink S.S. Matt Finish With Waste Coupling,
Waste Pipe,etc. cutting and making good the
walls wherever required.
b 10.00 Providing and fixing Under counter Wash
basine including 15 mm C.P. Brass Pillar tap,
32 mm C.P. Brass Waste of Standard make,
Cutting & Making good the wall / granite
Wherever Required in White Color : Model
S2030101 of Cera Clair Series or Equivalent
make Waash basine of size : 520x450 mm
c 8.00 Providing and fixing Wall Hung wash
basin Including 32 mm C.P. brass waste
of standard pattern, Include All
Accessaries, cutting and making good
the walls / granite wherever require:In
White Color : Cera Cadal Or Equivalent
Make Wash basin of size 515 x 410 mm
d 2.00 Providing and fixing Kitchen sink with C.I. or No.
M.S. brackets, painted white including cutting
holes in walls and making good the same but
excluding fittings. (C) Vitreous China Sink.(i)
600mm x 450mm x 150mm size
e 2.00 Providing and fixing C.P.brass waste for 67.24 No.
wash basin or sink. (A) 32mm dia.
f 2.00 Providing and fixing M.I. fisher union for 77.97 No.
wash basin or sink. (A) 32mm dia.
39a 6.00 Provdg. & fixing 600mm x 450 mm
Bevelled edge mirror of superior glass
mounted of .6 mm th. A.C. sheet or
plywood sheet and fixed to wooden
pluge with C.P. brass screws and
washers. 825.48 No.
40 4.00 Provdg. & fixing C.P..Brass towal rail
complete with C.P. brass brackets fixed
to wooden plugs with C.P. Brass
screws.(600 mmx 20 mm size)
41 Providing and fixing ball valve (brass) of
approved quality, High or low pressure,
with plastic floats complete :
ii 1.00 20 mm dia 1099.94 No.
iii 12.00 25 mm dia 1552.93 No.
iv 1.00 40 mm dia 3312.60 No.
42a Providing and fixing Full Way valve
(HEX) with wheel of approved quality :
i 2.00 15 mm Full Way valve (HEX) 1461.17 No.
ii 1.00 20 mm Full Way valve (HEX) 1924.61 No.
iii 10.00 25 mm Full Way valve (HEX) 2535.55 No.
iv 1.00 32 mm Full Way valve (HEX) 3377.64 No.
v 5.00 40 mm Full Way valve (HEX) 4661.10 No.
vi 2.00 50 mm Full Way valve (HEX) 6675.14 No.
Providing and Fixing of C.P.Brass Pillar
Cock of 15 mm Dia of Jaquar make
model no. 5011n or equivalent make with
all necessary fittings. as approved by
Engineer - in - charge., 1725.21 No.
b 4.00 Providing and Fixing of swan neck Sink
Tap Wall mount/Plateform Mount Jaquar
make model no. 5357n or equivalent
make. Rate shall Including of cost of
labour, material, necessary fittings etc.
Providing fixing of SS grab bar of Jaquar
make model no. 1507 or equivalent
make with all hardwares for Physically
Handicap toilet. 1937.24 No.
44a 345.00 Providing and laying integral cement
based water proofing treatment including
preparation of surface as required for
treatment of roofs, balconies, terraces
etc consisting of following operations:
(a) Applying a slurry coat of neat cement
using 2.75 kg/sqm of cement admixed
with water proofing compound
conforming to IS. 2645 and approved by
Engineer-in-charge over the RCC slab
including adjoining walls upto 300 mm
height including cleaning the surface
before treatment.
(b) Laying brick bats with mortar using
broken bricks/brick bats 25 mm to
mm size with 50% of cement mortar 1:5
(1 cement : 5 coarse sand) admixed with
water proofing compound conforming to
IS : 2645 and approved by Engineer-in-
charge over 20 mm thick layer of cement
mortar of mix 1:5 (1 cement :5 coarse
sand ) admixed with water proofing
compound conforming to IS : 2645 and
approved by Engineer-in-charge to
required slope and treating similarly the
adjoining walls upto 300 mm height
including rounding of junctions of walls
(c) After two days of proper curing
applying a second coat of cement slurry
using 2.75 kg/ sqm of cement admixed
with water proofing compound
conforming to IS : 2645 and approved by
Engineerin- charge.
(d) Finishing the surface with 20 mm
thick jointless cement mortar of mix 1:4
(1 cement :4 coarse sand) admixed with
water proofing compound conforming to
IS : 2645 and approved by Engineerin-
(e) The whole terrace so finished shall
be flooded with water for a minimum
period of two weeks for curing and for
final test.“All above operations to be
done in order and as directed and
specified by the Engineer-in-Charge :and
shall be guaranteed for minimum period
of 10 years after handing over the
completed building by the main
contractor to be finished as directed.
Stamp paper guarantee 10 years to be
furnished before receiving any payment
from the client.
With average thickness of 120 mm and
minimum thickness at khurra as 65 mm.
b 345.00 Providing and laying broken chine
mosaic flooring for terrace using 12 mm
to 20 mm broken pieces of glazed tiles to
be laid over cement mortar 1:3 to plain or
slope and to be tempered to bring mortar
creme out upto surface using white
cement including rounding off junctions
and extending them upto 15 cm along
the wall,clearing with water and oxalic
acid etc. as directed.
Providing and applying fibre reinforced
elastomeric liquid water proofing
membrane with resilient acrylic polymers
having Sun Reflectivity Index (SRI) of
105 on top of concrete roof in three coats
@10.76 litre/ 10 sqm. One coat of self-
priming of elastomeric waterproofing
liquid (dilution with water in the ratio of
3:1) and two coats of undiluted
elastomeric waterproofing liquid (dry film
thickness of complete application/system
not less than 500 microns). The
operation shall be carried out after
scrapping and properly cleaning the
surface to remove loose particles with
wire brushes, complete in all respect as
per the direction of Engineer-in-Charge. 562.4 Sq. M.
d 12.00 Filling in Sunken Portion with good
Quality Aerated light weight concrete
block having crushing strength not less
than 35 kg/sqcm and where directed by
the Architect / Engineer-in-charge, in
sunk in layer. including watering,
ramming where it is required etc.
complete, as directed by the Architect /
Engineer-in-charge .
45 100.00 Providing and laying cement concrete
flooring ( I.P.S.) 1:2:4 (1-cement : 2-coarse
sand : 4-graded stone aggregate 20mm
nominal size) laid in one layer and finished
with a floating coat of neat cement. (B)
50mm thick. 348.08 Sq.M.
46a 6000.00 Providing & Fixing M.S.grill, gate,stair /
balcony railing , elevation element of
Decorative pattern with M.S. Channel
,flat ,medium grade m.s. pipe, square or
round bars with round heanded bolts,
nuts, or by screw. etc. comp.
b 280.00 Applying priming coat over new steel and
other metel surface after and including
preparing the surface by throughly
cleaning, oil, grease, dirt and other
foreign matter and scoured with brushes
fine steel wood, scrapers and sand
paper with ready mixed priming paint
brushing red lead.
c 280.00 Painting two coats (excluding priming
coat) on new steel and other metal
surface with enamel paint, brushing,
interior to give an even shade including
cleaning the surface an even shade
including cleaning the surface of all dirt,
dust and other foreign matter.
Providing & Fixing 1 mm Thick S.S.-304
Grade 90 cm High S.S. Railing having
Hand Rail Member of 50 mm Dia., 3 No.
of Horizontal Pipe of 16 mm Dia. &
Baluster Suppprt of 40 mm Dia. At Every
Third Step as per Detail Given. Rate
Includes All Work Complete as per
Description & as per Direction of Engg.
in Charge. 2270.21 R.Mtr.
47a 27.0 Providing and fixing in position
collapsible steel shutters with vertical
channels 20x10x2 mm braced with flat
iron diagonals 20x5 mm size with top &
bottom rails of T-iron 40x40x6 mm with
38 mm dia. Steel pulleys complete with
bolts , nuts , locking arrangement
stoppers , handles including applying a
priming coat of red lead paint.
b 5.00 Providing corrugated 0.80 mm (22
gauge) thick G.I. sheets roofing fixed
with galvanized iron ‘J’ or ‘L’ hook bolts,
and nuts 8 mm. dia with bitumen and G.I.
limpet washers filled with white lead
complete excluding the cost of purlines,
rafters and trusses.
c 3.00 Providing valleys 900 mm. overall in
plain 1.6 mm. thick G.I. sheet Class –
fixed with ‘J’ or ‘L’ hook bolts and nuts
galvanized from ‘J’ or ‘L’ hook bolts and
bitumen washers complete.
48 9.0 Providing and fixing rolling shutters of
approved make made of 80 mm wide
M.S. laths inter-locked together through
their entire length and jointed together at
the ends by end locks mounted on
specially designed pipe shaft with
bracket plates, guide channels and
arragements for inside and outside
locking with push-pull operation including
the cost of hood cover and spring etc.
complete.(B) Shutters having width
49a 10.00 Providing and fixing 27mm domal Series
- 1.2 mm Th. Alluminium Section Two
track Sliding window With Metalic
Powder Coating and 4 MM Clear
Glaas(Non Tuffen) Include All
Accessaries and Fixture etc. complete as
per the direction of Engineer-in-charge.
49b 85.00 Providing and fixing 27mm domal Series
- 1.2 mm Th. Alluminium Section Three
track Sliding window With Metalic
Powder Coating and 4 MM Clear
Glaas(Non Tuffen) Include All
Accessaries and Fixture etc. complete as
per the direction of Engineer-in-charge.
50 16.00 ALUMINIUM DOOR WORK
Providing and fixing Aluminium Door
work (Single Shutter OR Double Shutter
with or without fix glass) made from
Jindal or equivalent make Powder
Coated (50 micron pure polyester
coating ) ,aluminium section frame built
up standard tubular and other section of
approved make confirming to IS 733 and
IS 1285 , member size with shutters of
horizontal member , vertical member
Confirming to IS733 and IS 1285 fixed
with rawl plug abd screws or fixing clips
or with expansion hold fasteners
including necessary filling up of gaps at
junctions at top bottom and sides with
required PVC/ Neoprene felt, 8/12 mm
toughened glass of approved make etc.
Aluminum sections shall be smooth, rust
free, straight.mitred and jointed
mechanically wherever required
including Door Hardware such as cleat
angles aluminum snap beading for
glazing /paneling, CP Brass/ Stainless
steel screws, Stoppers, heavy duty floor
hing, S.S. Hinges, aldrop , Locking
system, heavy duty Floor Springs, Pivot
and fixtures and transparent silicon
sealant glass fixing to frame as per
details all complete as per architectural
drawings and the direction of Engineer in
Charge. rate incl. all type of alumnium
sections for doors as per the detail
Architectural dwg. 5401.70 Sq. M.
51a 6.00 Providing and fixing standared extruded
of alluminium section of size 63 mm x
38.10 mm x 1.2mm (Section:2434, @
Wt.0.643Kg/mt ) with colour anodized
alluminium frame for ventilation with
mm thick Frosted glass as details etc
complete for Ventilation
51b 5.00 Providing and fixing standared extruded
of alluminium section of size 63.50 x
38.10 x 1.95 mm ( Section no:
@Wt 1.094 Kg / Rmt with colour
anodized alluminium frame with 5 mm
thick transparent bronze colour tinted
float glass as details etc complete for Fix
51c 80.00 Providing Fixing 1.2 mm thick Alluminium
Section Partition -Fully Glazed / Partly
Panelled Partly Glazed / Fully Panelled
Having Size of Section of 2.1/2 x 1.1/2
with 4 mm Compact Sheet / 5 mm thick
Glass Fixing with 4 mm thick EPDM
Rubber etc. Complete as per Direction of
Consultant / Engg.incharge.
3124.44 Sq.mtr.
51d 8.00 Providing Fixing 1.2 mm thick Alluminium
Section Partition Door -Fully Glazed /
Partly Panelled Partly Glazed / Fully
Panelled , frame Having Size of Section
of 2 .1/2 x 1 .1/2 and Door Section
Having Size of Tips Vertical 1 .3/4 x
.3/4, Top Rail 4 x 1 .3/4, Middle Rail
.3/4 x 1 .3/4, Bottom rail 4 x 1 .3/4 with
4 mm Compact Sheet / 5 mm thick Glass
Fixing with 4 mm thick EPDM Rubber
Including Lock, Handle, Door Closer,
Door Stoper, Stopper etc Complete as
per Direction of Consultant /
4061.77 Sq.mtr.
Providing and fixing ISI marked 32 mm
thick flush door shutters conforming to IS
: 2202 (Part I) decorative type, core of
block board construction with frame of
1st class hard wood and well matched
teak 3 ply veneering with vertical grains
or cross bands and face veneers on both
faces of shutters with 1.00 mm thick
Decorative Laminated Sheet on both
faces of shutters including ISI marked
Stainless Steel butt hinges, bright /matt
finished 125 mm Stainless Steel handles
of approved quality & make, ISI marked
oxidised M.S. door latches / Aldrop of
Size 300x20x6 mm conforming to
IS:5930 with necessary screws etc.
complete as per direction of Engg.
a 73.00 Flush shutter with both side laminate 4332.15 Sq.M.
b 136.00 Providing wood work in frames of Doors,
windows cleare story windows and
othersimilar works wrought, framede and
fixed in position. (A) Indian Teak Wood 602.04 Cu.Decim
53 Providing and fixing 35 mm th. Shutters
for doors windows & clearstory windows
incl. wood frames as specified 12 cm. x
7cm. size incl. anodised alluminium
fixtures and fastenings including primer
coat of approved quality and two coats of
oil paint etc. complete.
a 3.00 Fully glazed 4788.50 Sq. M.
b 3.00 Fully panelled 5478.89 Sq. M.
c 3.00 Partly panelled and partly glazed 5133.69 Sq. M.
54 15.00 Providing and fixing FRP frame size
100x50 mm and 28mm thick FRP
depress panel shutter having extra
reinforcement on sides & edges in Gel
coat finish. The core of the shutter &
frame is to be filed up with injected fire
retardant grade polyurethene foam done
in situ alongwith embedded wooden
pieces for stiffening & also taking hinges
& fintures. The whole FRP frame &
shutter is to be water proof weather
proof, termite proof & resistance to mild
acid/alkali. Rates are to be inclusive of
S.S hinges with necessary screws &
alluminium fixtures & fastenings &
fastener sleeve.
55 Making connection to the ex.M.H.in
running sewer incl. Dewatering and other
required machinery etc. of following dia
pipes at any convenient time. All
damaged work shall be well repaired as
per instructions. etc..complete.
a 1.00 For Pipe 150 mm to 300 mm diameter 1339.29 No.
b 1.00 For Pipe 400 mm to 600 mm diameter 2232.14 No.
56 1.00 Making connection of galvanised Mild
steel distribution branch with galvanised
mild steel main pipe upto 80mm nominal
bore by providing and fixing tee including
cutting and threading the pipes complete
57a 550.00 Providing throating or plaster drip,
grooves and moulding to Wall , R.C.C.
chajja and slab.
57b 80.00 Providing & Laying cement vatta 10 cm x
10 cm in size quarter round in c.m. 1:1 (
1 cement, 1 coarse sand) laid in one
layers finishing with a floating of neat
cement watering etc complete as dire.
58 350.00 Carring out plinth treat ment to post
construction/ existing structure by
spraying chemical solution for termite
control treatment including labour and
material consist ment withI.S.I
specification. Using Chlordene and
Chiorpur files 20EC. As Per 6131_ paret-
II Consentration Weight one percent is
recommended i.e one litre 20EC
chemical emulsion with19 liter give1%
concrentration inclusive of one litre
chemical emulsion appication at the rate
of 5 Litre chemical/ Sqm of surface is
recommended as per I.S
59 10.00 Carring out timber treatment to all wood
work including drilling holes and spraying
oil based chemical solution on surface of
timber work for termite control including
labour and material etc. complete. Using
Chlordene 20EC. As Per 6113_part III
Consentration Weight 1.00 percent is
recommended one litre chemical
emulsion dillute with 9 liter of kerosene
precent concentration. Total dillute
concrentration will be10litre inclusive of
the litre chemical emulsion application
0.75/Litre chemical per one Sqmt printed
two coat wood surface.
60 120.00 Paver Block Providing and laying shot
blasted Non - interlocking, Paver blocks of
specified thickness, size, grade of concrete
and colour machine made and blasting by
automatic shot blasting machine and high
density of as per approved sample of
approved make for footpath, parking areas,
service lanes,cross over and other areas as
mentioned in the drawing. Including providing
and laying 50 mm thick averave bedding
layer of coarse sand below paver block as
per required grading and specification. Laid
paver block shall be mechanically
compacted. The work of the paving blocks
shall be executed in line and level by skilled
mason of flooring work only. Small size of
paver block with same specification shall be
used at residue or at end. It should be laid in
such a way that the no cutting of the paver
block to be necessary. If cutting of paver
block shall be required , than cut by machine
only and laying to be done by skilled flooring
mason. The finished surface of the paver
block shall have coarse sand Texture Finish.
Pave blocks shall be compacted and shall be
re-laid if necessary. Actual laid area shall be
measured and paid without any wastage. (A)
80 mm thick M-35 grade Grey Paver block of
size 200mm x 200mm. As per approved rate
61 180.00 SProviding and fixing pre-cast concrete
kerb stone of gray cement based
concrete block 30cm length,30cm height
and 15cm thick of M250 grade concret
as per approved design and including
excavation for fixing in proper line and
level,filling the joint with C:M 1:3
(1cement:3fine sand) etc complete.
Providing and fixing double action
hydraulic floor spring of approved brand
and manufacture conforming to IS :
6315, having brand logo embossed on
the body / plate with double spring
mechanism and door weight upto
kg, for doors, including cost of cutting
floors, embedding in floors as required
and making good the same matching to
the existing floor finishing and cover
plates with brass pivot and single piece
M.S. sheet outer box with slide plate etc.
complete as per the direction of
Engineer-in-charge. With stainless steel
cover plate minimum 1.25 mm thickness 4558.89 No.
Providing and fixing aluminium extruded
section body tubular type universal
hydraulic door closer (having brand logo
with ISi, IS : 3564, embossed on the
body, door weight upto 36 kg to 80 kg
and door width from 701 mm to
mm), with double speed adjustment with
necessary accessories and screws etc.
complete. 1626.10 No.
63a 35.00 Designing, fabricating, testing, installing
and fixing in position Curtain Wall with
Aluminium Composite Panel Cladding,
with open grooves for linear as well as
curvilinear portions of the building , for all
heights and all levels etc. including:
(a) Structural analysis & design and
preparation of shop drawings for
pressure equalisation or rain screen
principle as required, proper drainage of
water to make it watertight including
checking of all the structural and
functional design.
(b) Providing, fabricating and supplying
and fixing panels of aluminium
composite panel cladding in pan shape
in metalic colour of approved shades
made out of 4mm thick aluminium
composite panel material consisting of
3mm thick FR grade mineral core
sandwiched between two Aluminium
sheets (each 0.5mm thick). The
aluminium composite panel cladding
sheet shall be coil coated, with Kynar
500 based PVDF / Lumiflon based
fluoropolymer resin coating of approved
colour andshade on face # 1 and
polymer (Service) coating on face # 2 as
specified using stainless steel screws,
nuts, bolts, washers, cleats, weather
silicone sealant, backer rods etc.
(c) The fastening brackets of Aluminium
alloy 6005 T5 / MS with Hot Dip
Galvanised with serrations and serrated
washers to arrest the wind load
movement, fasteners, SS 316 Pins and
anchor bolts of approved make in SS
316, Nylon separators to prevent bi-
metallic contacts all complete required to
perform as per specification and drawing
The item includes cost of all material &
labour component, the cost of all mock
ups at site, cost of all samples of the
individual components for testing in an
approved laboratory, field tests on the
assembled working curtain wall with
aluminium composite panel cladding,
cleaning and protection of the curtain
wall with aluminium composite panel
cladding till the handing over of the
building for occupation. Base frame work
cost for ACP cladding is included in this
item rate. The Contractor shall provide
curtain wall with aluminium composite
panel cladding, having all the
performance characteristics all complete
, as per the Architectural drawings, as
per item description, as specified, as per
the approved shop drawings and as
directed by the Engineer-in-Charge.
However, for the purpose of payment,
only the actual area on the external face
of the curtain wall with Aluminum
Composite Panel Cladding (including
width of groove) shall be measured in
sqm. up to two decimal places.
b 24.00 Providing and fixing Structural Glazing
with using the 17 Micron anodised of
approved colour alluminium section as
transium, mullium of size 63mm x 38mm
x 2 mm with using 6 mm thick reflective
structural glass of approved make,
colour / Tinted, toughned and shade and
fixed with silicone sealant and spacer tap
and at corner sealed neoprene foam
dust and Air sealed gasket mirred
including scaffolding, cleaning of glass
etc.complete at all heights anf lifts with
all necessary fitting and fixtures, anchore
fasteners, necessary M.S. or Aluminium
brackets, suitable design for openable or
sliding window as per Architectural
drawing and as directed by Engineer-in-
charge. Grooves between the glasses to
be filled with sealant of Dow corning -
structural sealant 995, weather sealant
789. The entire facade should be water
proof. The mullions are to be connected
to bracket by SS-304 nut bolts.
Measurement shall be given as per
actual execution of the work. (Rate are
included providing & fixing of MS
structure steel work wherever Required)
Providing and Fixing Box type metal
letters forming composite box made from
1mm thick stainless steel plate of grade
304 having brush finish of following font
size to be fixed at Main Gate in english
and or Gujrati and including fixing
charges. etc. complete as per direction
of Engg. incharge. for Payment Purpose
Height of Letter will be measured.
a 960.00 Upto 300 mm Height 93.85 R. Inch
Providing and Fixing MURAL made out
of 2mm thick s.s. plate grade
including making necessary design as
per Architect dwg. Through laser cutting
including connection to the
R.C.C./Masonary with necessary
frame,anchor fastnuts,M.S.Plate etc.
complete as per direction of Engg.
incharge. 6804.07 Sq.mt.
65b 4500.00 Providing and Fixing Sinage - internal
and external signage boards with Vinyle
Text on ACP sheet / 2 mm th. S.S. Plate
etc. complete as per direction of Engg.
65c 5.00 Providing and fixing retro Reflective Hi
Intensity Micro Prismatic Grade Board
using 2mm Aluminum / 4mm ACP, angle
iron 75 x 75 x 6mm. Descaling and
degreasing the board as per requirement
using epoxy reflactive process by screen
painting as directed etc. complete
including transporting and fixing in C.C.
1:2:4 with necessary excavation curing
etc. complete as per I.R.C. 67-2012
design. A warranty for 7 years for the
Retro reflective sheeting from original
manufacturer & a certified copy of 3 year
outdoor exposure test report from third
party test lab for the product offered shall
be submitted by contractor. (B)Class B
Type-4(MDR/ODR) retro reflective
7535.31 Sq.mtr.
65d 50.00 Road marking with hot applied
thermoplastic paints with reflectorising
glass beads on bitumin surface providing
and laying a hot applied thermoplastic
compound 2.5 mm thick including
reflectorising glass beads @ 250gms per
sqm area, thickness of 2.5mm is
excluding of surface applied glass beds
as per IRC:35-2015. The finished
surface to be level, uniform and free from
streaks and holes. zebra patta /bump
patta lane/center line/ edge line/cut
patta. The white color marking should
provide liminance coefficinet on cemend
road shalll be min 130 mcd/m2/lux and
Asphalt road shall be min
mcd/m2/lux during the service life during
the day time. The marking should meet
the performance criteria for night time
reflectivity, wet reflectivity and skid
resistance as mentioned in the section-
15 of IRC 352015. Warranty for the
Retro reflectivity should be two years.
65e 5.00 CAT EYE/Pavement Marker(MNC two
nail) made out of acrylic
StreneAcrylonitrile or hi-impact poly
Steren fitted with moulded of
metheacrylate(MNC)reflector cube
corner reflector design,filled with tightly
adhering pooting compound as per
ASTMD-788 size 11.5x7x1.60 cms or
10x10x1.75 cms provided with
bituminous adhesive in sufficient quantity
with each unit fixing with two shrank
.Reflector on both side.Co efficient of
lumination as per specification and
compressive strenth 13 tones at
degree centigrade etc.B) Double side
66a 35.00 Providing and fixing eco-friendly light
weight calcium silicate false ceiling tiles
having T egular edge & 15mm Thick
Densified edges on the Tile Periphery for
Extra Strength The Light weight calcium
silicate ceiling tiles shall have, light
reflection 85% non-combustible as per
B.S.476 part IV, 100% humidity
resistance and also having thermal
conductivity 0.043° w/m KC. for the best
thermal Insulation.
The Light weight calcium Silicate tile
shall be of approved texture Fine
fissured/ Spintone/ Cosmos having NRC
value of 0.5 & Globe having NRC value
of 0.75 NRC or equivalent of size
595X595 mm to be laid on true
horizontal level suspended inter locking
metal grid of hot dipped galvanized steel
sections (galvanizing @ 120 grams per
sqm including bothside) consisting of
main ‘T’ runner suitably spaced at joints
to get required length and size of 24X38
mm made from 0.30 mm thick (minimum)
sheet, 1200 mm centre to centre, and
cross ‘T’ of size 24X28 mm made out of
0.33 mm (Minimum) sheet spaced
mm along spaced between main ‘T’ at
600 mm centre to centre to form a grid
of 1200X600mm and secondary cross ’T’
of length 600mm and size 24x28mm
made of 0.30 mm thick (Minimum) sheet
to be interlocked at middle of the
1200X600mm panel to form grid of size
600X600mm resting on periphery walls /
partitions on a perimeter wall angle pre-
coated steel of size (24X24X3000mm
made of 0.40mm thick (minimum)
sheet with the help of rawl plugs at
450mm centre to centre with 25mm long
dry wall screws @ 230mm interval and
laying 15mm thick Densified edges light
weight calcium silicate ceiling tiles of
approved texture (Fine Fissured/
Cosmos/Spintone) in the grid including,
cutting /making opening for services like
diffusers, grills, light fittings, fixtures,
smoke detectors etc., wherever required,
Main ‘T’ runners to be suspended from
ceiling using G.I. slotted cleats of size
25X35X1.6mm fixed to ceiling with
12.5mm dia and 50mm long dash
fasteners, 4mm G.I. adjustable rods with
galvanized steel level clips of size
85X30X0.8mm, spaced at 1200mm
centre to centre long main ‘T’ bottom
exposed with 24mm of all T-sections
shall be pre-painted with polyester baked
paint, for all heights,
, as per specifications, drawings and as
directed by engineer-incharge.Note:-
Only calcium silicate false ceiling area
will be measured from wall to wall. No
deduction shall be made for exposed
frames/ opening (cut outs) having area
less than 0.30 sqm. The calcium silicate
ceiling tiles shall have NRC. Value of
0.50 (Minimum) for Fine fissured/
Spintone/ Cosmos and 0.75 NRC for
Globe, light reflection 85%
noncombustible as per B.S. 476 part IV,
100% humidity resistance and also
having thermal conductivity. 0.043° w/m
KC.for the best thermal Insulation
66b 35.00 Providing and fixing single layer water
proof gypusm board 12.5 mm thick of the
make New good Group Co.Ltd. or
equivalent & New good Group Co.Ltd.
company sections using water proof
board of size 1220 mm x 1830 mm x
mm suspended by G.I suspender of size
25 mm x 3 mm with intermediate channel
of size 18mm x40mm x0.80mm at
mm center to center ceiling section of
size 40mmx 35mmx 0.55mm at 457 mm
center to center and perimetre chanel A
of size 20mm x 27mm x 30mm x
0.50mm at edges & drops including
paper taps and sofit cleat, anchor
fastener, scoch bolt connecting cleat
joining compound top coat on ceiling
including making necessary opening for
light fitting, diffuser etc. complete as per
detail drawing as directed.
67a Providing and Fixing 6 mm thick Lexan
Polycarbonate multi wall roofing sheet
fixed with hilti screw and rubber silicon
sealer and alluminium strip of size 50 x
mm etc complete as directed by
Engineer in charge
b Providing Making & Fixing Glow sign
Board of suitable size as per approved
color-Designed Back Light Material fixed
on G.I. sheet Box of suitable size with
concealed Light Fittings, Necessary
Scaffolding etc. complete as per
direction of Officer in charge.
68 Providing and supplying ISI Standard RCC
pipes (of sulphate resisting Cement )in
standard lengths of following class and
diameter suitable for rubber ring joints
(socket and spigot) including all
taxes,insurance, transportation,treight
charges,octroi,inspection charges,
loading,unloading, conveyance to
departmental stores, stacking etc. comple
Class NP3 Test pressure 0.7 Kg/Sq.Cm
a 90.00 300 mm Diameter 755 Rmt
b 10.00 450 mm Diameter 1361 Rmt
68 Lowering, laying and jointing R.C.C. pipes in
C.M.1:1 1/2 of following diameters in proper
position , grade and alignment at all level as
directed by Engineer-in- charge including
conveyance from stone to site of work,
labour giving hydraulic testing as per ISI
C 90.00 300 mm Diameter 119 Rmt
D 10.00 450 mm Diameter 171 Rmt
Constructing Bombay Pattern Type
Catch Pit of size 0.60 x 0.60 depth up to
1 mt including excavation, B.B.C.C.
(1:5:10), 23 cms thick brick maso. wall in
the prop. of CM (1:6) with 40 mm thick
IPS flooring in the prop M15 at bottom
and 15 mm thick cement plaster inside
the catch pit in the proportion of CM (1:3)
with out jali etc. comp. as directed.
CatchPit Jali Fixing P/F FRC catch pit jali
with frame 600mm x 600mm clear
opening etc. comp.. As directed by
engineer in charge.
PERCOLATION WELL
Drilling of pilot bore hole in Alluvial Strata
120 by direct Rotary Rig of 250 mm. 694.64 Rmt
72 Reaming 400 mm
73 Electro Logging charges with carting
Providing and Installing 200 mm dia
74 IS:12818 upvc Casing Pipe "CM" class
60 plain Pipe 1,193.75 Rmt
Providing and Installing 200 mm dia
75 IS:12818 upvc End Cap, with Air Vent
1 cowl 669.64 Set
200 mm dia Regular with 1.5 mm sloted
size cage type trapezoidal shape wire
wound little carbon galvanized screen
60 confirming to IS:8110 1,146.43 Rmt
77 Supply of Pea sized Gravel
78 Air Vent of 50 mm Bend
Lowering and Removing of Dropline up
120 to Depth 186 mtr. 147.32 Rmt
80 Air Compressor 60 CFM/150 PSI
Unit Rate Amount
Items Rs. Ps. Rs. Ps.
Electrical Work Estimate
1.0 INTERNAL WIRING
1.1 Point wiring for Light / Bell with 2-1.5 sq.mm &
earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade ZHFR/HRFR PVC
insulated multi strand copper wires up to 10 mtr
length , in below type of pipe erected with 6A
Modular type switch / bell push & accessories and
earth continuity of following type, erected on PVC
/ Metallic/Wooden box, single mounting base
frame covered with textured/metallic/white front
plate modules erected on / in wall / ceiling as per
pipe erected, with necessary Lamp holder/ceiling
rose / H.D.Connector as directed.
135 (f) with medium class Rigid PVC pipe and 505.05 Pt
accessories erected concealed in wall/ceiling
1.2 Point wiring for FAN with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (Green) both are of .ISI marked
1.1 KV Grade ZHFR/HRFR PVC insulated multi
strand copper wires up to 10 mtr length, in below
type of pipe erected with 6A Modular type switch
and hum free EME four or more step type
electronic fan regulator with separately mounted
and accessories with earth continuity of following
type erected on PVC / Metallic/Wooden box,
single mounting base frame covered with
textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe erected.
with necessary ceiling rose / H.D.Connector as
55 (f) with medium class Rigid PVC pipe and 701.40 Pt
accessories erected concealed in wall/ceiling
1.3 Point wiring for secondary light point with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (green) both
are of ISI marked 1.1 KV grade ZHFR/HRFR
PVC insulated multi strand copper wires, in below
type of pipe to be erected complete with earth
continuity and necessary connection with primary
light with accessories erected on Metal / PVC /
wooden box covered covered with appropriate
front plate modules erected on / in wall / ceiling for
open / concealed wiring. with necessary Lamp
holder / ceiling rose / H.D.Connector as
directed.as per pipe erected with following type of
Note:- Maximum up to 6 mtrs length, excess
will be considered as Mains for Secondary
105 (f) with medium class Rigid PVC pipe and 174.30 Pt
accessories erected concealed in wall/ceiling
1.4 Point wiring for Individual Plug with & earth wire
of 1.5 sq.mm (Green) both are of ISI marked
KV grade ZHFR/HRFR PVC insulated multi
strand copper wires up to 10 mtr length, in below
type of pipe erected complete with Modular type
switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate
front plate modules erected on / in wall / ceiling as
per pipe erected with following type of
1.4.1 70 [I] For 6A Plug and 6 a switch with 2-1.5 530.25 Pt
sq.mm Cu. Wire from nearby switchboard/mcb
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
1.4.2 15 [II] For 16A Plug and 16 amp switch with 2-2.5 774.90 Pt
sq.mm Cu. Wire from mcb db board.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
1.4.3 14 [III] For 16A Plug and 16 amp switch with 2-4 906.15 Pt
sq.mm Cu. Wire with 2.5 sq.mm ( green)
earthing wire from mcb d b board.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
1.5 120 Point wiring for on board Looped Plug with 6A 255 Pt
Modular type switch & 5 pin socket erected on
PVC / Metallic/Wooden box, single mounting base
frame covered with textured / metallic/white front
plate modules erected on / in wall / ceiling with
following type accessories
1.6 Point wiring for Two Way Controlled Light Point
with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(green) both are of .ISI marked 1.1 KV grade
ZHFR/HRFR PVC insulated multi strand copper
wires erected in below type of pipe with 6A
Modular type switches and following type of
accessories erected on PVC / Metallic/Wooden
box, single mounting base frame covered with
textured / metallic/white front plate modules
erected on / in wall / ceiling as per pipe erected.
with necessary batten/angle holder or ceiling rose
or H.D.Connector as directed.
5 (f) with medium class Rigid PVC pipe and 627.90 Pt
accessories erected concealed in wall/ceiling
1.7 Providing following type of Modular Type
Accessories mounted with PVC / metallic/Wooden
box, single mounting base frame covered with
textured / metallic/white front plate , modules
erected with necessary connections as per site
situation directed by Engineer In charge.
1.7.1 2 (1)One No. SP 6 Amp. 150 E.a.
1.7.2 2 (2) One No 5 pin plug 150 E.a.
1.7.3 40 (7) Blank Plate Single 25 E.a.
1.7.4 14 (8) Computer RJ-45 socket 159 E.a.
1.7.5 8 (9) 16 Amp. SP one way switch 179 E.a.
1.7.6 8 (10) 6/16Amp. Universal socket 198 E.a.
1.7.7 4 (13) 6A/10A/16A/20A/25A/32A Single pole 307 E.a.
Modular MCB Switch
Modular MCB Switch
1.8 Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete to
be erected on/in wall or ceiling erected with
necessary PVC fittings & Junction boxes fixed
with adhesive solution & Clamps with following dia
of pipes, in approved manner as directed
1.9 Providing & erecting PVC Corrugated Flexible
Conduit with required nos. of coupling, PVC
bushes, Check-nuts etc. complete of following
1.10 providing and erecting Mains with ISI marked
electrolyte stranded copper conductor, Non PVC
Zero Halogen free fire retardant insulated copper
conductor, insulated wire (HRFR) conforms to IS-
694, erected in existing pipe with 1.5sq. mm
copper conductor of same specifications for earth
continuity of following size.
In Existing medium class Rigid PVC pipe and
1.10.1 780 (a) 2 wire 1.5 sq. mm 51 Mtr
1.10.2 1460 (b) 2 wire 2.5 sq. mm 71 Mtr
1.10.3 120 (a) 2 wire 4 sq. mm 101 Mtr
1.10.4 340 (b) 2 wire 6 sq. mm 139 Mtr
1.11 providing and erecting Mains with 1.1 KV grade
FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be
erected in / on wall / ceiling with 2.5 sq. mm
copper conductor FRLS PVC insulated
stranded wire of green colour for earth
continuity of following size
(A) with medium class Rigid PVC pipe and
1.11.1 80 (h) 4 wire 6 sq. mm 258 Mtr
1.11.2 90 (i) 4 wire 10 sq. mm 421 Mtr
(use earth wire of 4 sq.mm )
1.12 providing and erecting Mains with ISI marked,
1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC
insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for
control panel, relays, power switchgears,
motor starters & control wiring) with required
size of copper lugs, nuts and bolts if required.
1.12.1 10 (e) One wire 6.00 sq. mm 56 Mtr
1.12.2 10 (f) One wire 10.00 sq. mm 91 Mtr
1.12.3 20 (g) One wire 16.00 sq. mm 141 Mtr
1.12.4 10 (h) One wire 25.00 sq. mm 234 Mtr
1.12.5 40 (i) One wire 35.00 sq. mm 298 Mtr
1.12.6 20 (j) One wire 50.00 sq. mm 466 Mtr
1.13 Supplying and erecting Flexible PVC insulated
multi strand multi core 1.1 kv grade ISI marked
copper wires of following size to be erected as
1.13.1 170 e) 1.50 Sq.mm 3 core round PVC sheathed 46 Mtr
1.13.2 110 h) 2.50 Sq.mm 3 core round PVC sheathed 77 Mtr
1.13.3 20 k) 4.00Sq.mm 4 core round PVC sheathed 175 Mtr
1.14 Supplying & erecting M.S. Box having 16 Gauge
painted with red oxide or Heavy duty PVC box
erected flushed on wall or concealed in wall with
necessary plastering & finishing as directed of
following size.
1.15 Supplying and laying UPVC cable trunking system
comprising unplasticised polyvinyl, chloride rigid
material with ignition free and flame proof
confirming BS with necessary end caps Internal
and external bend, flat bends, coupler, tee etc..All
necessary accessories and measuring of following
1.15.1 5 (2) 100 mm x 50 mm trunking 424 Mtr
1.15.2 5 (4)100 mm x 50 mm trunking with TWIN 1309 Mtr
compartment With clip in divider
1.16 Supply & installation of surface mounted U PVC
snap-on adaptable trunking raceways, fabricated
out of U-PVC to Off-White or approved shade as
per IS 733 of thickness 2.0mm for the base and
sides with all accessories like removable covers,
joints ,height spacer,angles complete with
necessary bends, suitable sized junction boxes
and tees etc, Complete.
5 (a)Size: 50x80mm PVC Raceways for Power & 1052 Mtr
Data with 2 compartments above specifications.
1.17 Supply & installation of modular type accessories
for U PVC snap-on adaptable trunking/Pop up
Box with required items erected with necessary
connection. As desired by Engineer In charge
1.17.1 2 i) 6 A SP 1 Way Switch 204 No
1.17.2 1 ii) 16A SP 1 Way Switch 351 No
1.17.3 2 iv) 6A universal socket shuttered 347 No
1.17.4 1 iv) 6/16 A universal socket shuttered 458 No
1.17.5 1 vi) Cat-6 LAN Socket 561 No
1.18 Supplying & erecting approved make Telephone
Cable electrolytic copper conductor PE insulation
twisted in two pairs, & wrapped with FRLS PVC
tape & sheathed with FRLS PVC or HFFR outer
Jacket suitable for telephone wiring & confirming
to C-DOT erected in existing pipe. of following
size of conductors & nos.of pairs. With necessary
(b) Armoured [Jelly Filled]
30 1) Ten Pairs 124 Mtr
1.19 LAN NETWORK
1.19.1 14 SITC of CAT6 UTP 24AWG PATCH 155 No
CORD:1M,Plug 30U' Snag less (Including Five
year free maintenance with guarantee)
1.19.2 14 SITC of CAT6 UTP 24AWG PATCH 199 No
CORD:2M,Plug 30U' Snag less (Including Five
year free maintenance with guarantee)
1.20 LAN SWITCH
1.20.1 1 SITC of 24 x 10/100/1000BASE-T ports 4 x 15247 No
Gigabit RJ45/SFP Combo ports Advanced L2
switching and security features L2+ Static Routing
Optional “standard mode” or “surveillance mode”
management user interface
1.20.2 1 SITC of Patch Panel UTP Keystone- 24 Port- 1485 No
Unloaded (Cat 5e,Cat 6 & Cat 6 A ) (Including
Five year free maintenance with guarantee)
1.21 Providing & erecting main Distribution (MDF)
indoor type, back mounted frame as per DoT
standard approved with krone strips
1 (a) Suitable for 10 pair 985 E.a.
1.22 Providing & Erecting Netwrok rack with following
capacity with Necessary cooling fan,Cable
manager,6A PDU,equipment rack with necessary
mounting accessories.
1.23 Supplying & erecting approved make LAN cable
of following size in existing pipe as per direction
380 [C] CAT - 6 47 Mtr
SUB - TOTAL OF INTERNAL WIRING
2.0 Switchgears , Panels , MCBDBs & MCBs
2.1 Providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 35 KA. at 415 V. having normal
current rating 125A. with Fixed thermal &
magnetic release suitable to work on A.C.supply
50 c/s. with all internal connections, spreader
tinned copper & complete erected in existing
G.M.S. housing.
1 ICS=100% of ICU only 8773.6 No
2.2 Providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 35 KA. at 415 V. having Normal
current rating 200A.with variable Thermal &
magnetic release suitable to work on A.C.supply
50 c/s. with all internal connections, spreader
tinned copper & complete erected in existing
1 ICS=100% of ICU only 17667.1 No
Providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 35 KA. and above at 415 V .
having normal current rating 250A. with variable
thermal & magnetic release suitable to work on
A.C.supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in
existing 16 G.M.S. housing.
1 ICS=100% of ICU only 22812.9 No
2.3 FABRICATION AND BUSBARS CHAMBER
2.3.1 18 Fabricating the box type items made from M.S. 179 Kg
Sheet with A.I. supports, wings, doors, handles
other hardware materials as per requirement
design with finishing by three tank powder coating
processed inside and outside painted, erected as
directed including minor civil work. to install above
2.3.2 Providing and erecting busbar chamber
confirming to IS-375 fabricated from 16 G.M.S.
sheet, dust & vermin proof having hinged door
with rubber gasket and necessary busbar
supports with COPPER busbar having current
density not more than 1.6 Amp. / sq.mm (Rated
current / cross section area) duly wrapped with
colour insulation tape for phase sequence, three
phase & neutral each suitable for following current
capacity with necessary painting mounted on wall
or pedestal frame of required size with necessary
1.5 (C) Suitable for 300 Amp. capacity 8455 RnMtr
2.3.3 providing and erecting Approved make Earth
fault Relay suitable to mount with inter
connection suitable to following size of moulded
case circuit breaker having CT ratio & MCCB
rating as following along with shunt trip 220V AC.
with all internal connections & complete erected in
existing M.S.housing..
2.4 Design, fabrication, assembling, supply,
installation, testing and commissioning of cubicle
type, wall / Floor mounted LT panel suitable for
415 V 3 phase, 4 wire 50 Hz AC supply system
fabricated in compartmentised design from CRCA
sheet steel of 2 mm thick for frame work ,Doors
and partitions IP 42 and covers,3 mm thick for
gland plates i/c cleaning and finishing complete
tank process in house facility for powder
coating in approved shade, extendable type FP
aluminium alloy busbars of high condectivity,
DMC/SMC busbar supports, entire panel shall
have a common copper earthbar of size 25mm X
5 mm at the rear with 2 Nos. earth studs, solid
connection from main busbar to switchgears with
require size of aluminium busbar & control wiring
with 1.5 sqmm FRLS insulated copper conductor
cable, cable alleys, cable gland plates i/c
accessrories as per specification and providing
switchgears, metering instruments etc. for
following panel.G.A.Drawing to be approved by
EIC or consultant. ( Outgoing connectors must be
nut-bolt type. Outgoing mains for 63Amp MCBs
must be of 4 x 16sqmm cu flexible
wires).Incomers Mains for MCBs shall be always
from the busbars.
( a ) Providing cable clamps / supports within
distribution boards cable alley.
( b ) All hinged door shall be earthed through
sq mm tinned b raided copper wire.
( c ) Pad locking of MCCB’s handles in “OFF”
( d ) All the C.T.s should be auto short link type.
( e ) All the MCCB's should be with rotary handle.
( f ) All incoming and outgoing air circuit breakers
shall be placed on middle portion of the vertical in
single tier formation.
( g ) Any descripancy found in SLD & Boq , it
should be brought in the notice of the client /
consultant, and the decision will be taken final by
Client / consultant.
2.4.1 Providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 35 KA. at 415 V. having normal
current rating 125A. with Fixed thermal &
magnetic release suitable to work on A.C.supply
50 c/s. with all internal connections, spreader
tinned copper & complete erected in existing
G.M.S. housing.
1 ICS=100% of ICU only 7976 No
2.4.2 Providing and erecting Approved make Three pole
moulded case circuit breaker having breaking
capacity ICU of 25 K.A. at 415 V having normal
current rating up to 25 A to 100A. with Fixed
thermal & magnetic release suitable to work on
A.C. supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in
existing 16 G.M.S. housing.
1 ICS=100% of ICU only 5302 No
2.4.3 providing and erecting Approved make Earth
fault Relay suitable to mount with inter
connection suitable to following size of moulded
case circuit breaker having CT ratio & MCCB
rating as following along with shunt trip 220V AC.
with all internal connections & complete erected in
existing M.S.housing..
2.4.4 6 providing and erecting Miniature circuit breaker 268 No
single pole 0.5A to 2A system and having
breaking capacity 10 KA to be erected in existing
box. confirming to IS 8828/1996 with ISI Mark
2.4.5 4 providing and erecting Miniature circuit breaker 111 No
single pole 6A to 25A suitable to operate on 240 V
A.C. system and having breaking capacity 10 KA
to be erected in existing box. confirming to IS
8828/1996 with ISI Mark
2.4.6 Providing & erecting 240 V MCB double pole
switch for motor & inductive load (C Curve)
having 10 KA breaking capacity & confirms to IS :
8828 in existing box having following capacity
2.4.7 Providing & erecting 415 V MCB Four Pole for
Motor & Inductive Load (C Curve) having 10KA
breaking capacity & confirms to IS :8828 in
existing box having following capacity
2.4.8 Providing and erecting following additional parts
for panel mounting MCCBs
2.4.9 4 (A)Extended operating rotary handle with pad lock 865
with three position trip,off,on suitable for 25A to
250 A panel mounting
2.4.10 1 Supplying and erecting approved make panel 1263 No
mounting type Digital Voltmeter having 3 digits
LED display, 0 to 750 AC Volts range erected on
existing panel board with all connection, wiring
etc .with manufacturers calibration certificate.
2.4.11 1 Supplying and erecting approved make panel 1543 No
mounting type Digital Ammeter having 3 digits
LED display, external CT operated, calibrated for
0 to 1000 Amps suitable to operate on 500 Volt
AC , erected on existing panel board with all
connection, wiring etc .with manufacturers
calibration certificate.
2.4.12 2 Supplying and erecting Ammeter / Voltmeter 314 No
selector switch for 3 phase AC Supply 500 V on
existing panel board with necessary connections.
2.4.13 6 Providing & erecting L.T. Current Transformer 272 No
with bar primary 50/5 to 1000/5 ratio 15 VA
burden erected in existing CRCA box duly
secured with insulating materials connected to the
2.4.14 1 Supplying & erecting approved make Power 5052 No
Factor Meter 150mm dia flush/projection type/
balanced & unbalanced load to work with
appropriately provided CT’s 100/5A to 400/5A
ratio & other accessories complete erected in
M.S. box & connected to the circuit by means of
PVC copper Core leads.
2.4.15 6 Supplying and erecting approved make suitable 43 No
panel indicator LED type lamp, lens cover,
complete erected with necessary connections.
2.4.16 4 Providing and erecting metallic vitrified danger 69 No
notice board as per language suggested by
engineer incharge for MEDIUM VOLTAGE
installation to be erected as per IS-2551.
2.4.17 2 Providing and erecting required size Aluminium 223 KG
strip for earthing of H.T. , OCB / ACB /
Transformer, LT panel board, Motors etc. using
2.4.18 2 Providing and erecting required size Copper strip 787 Kg
for earthing of H.T. OCB / ACB/ Transformer, LT
panel board, Motors etc. using copper clamp.
2.4.19 1 providng and erecting Approved make energy 2179 No
meter 3 phase 4 wire unbalanced load 500 V. 5 to
10A complete erected as directed with necessary
earth wire.Class-1
2.4.20 90 Providing , erecting , fabricating the M.S. structure 77 Kg
as per requirement on site incorporating proper
size of M.S. angles,square,round, flats, bars,
channels, sections complete with cutting, welding,
grinding & finishing duly painted with one coat of
red oxide with erection on site as per direction of
engineer in charge with necessary grouting,
cementing, plastering & finishing complete.
2.4.21 Supplying and erecting triple pole & neutral 440V /
500V panel mounting Copper Busbars with four
equal Nos. of electrolyte bus having current
density not more than 1.6 Amp. / sq.mm (Rated
current / cross section area) duly wrapped with
colour insulating tape for phase sequence of
following current carrying capacity, erected with
necessary bus bar supports /insulators, main
cable socket to each bar, erected in existing
cubical panel with necessary connections.
4 (C) Suitable for 300 Amp. capacity 4861 RnMtr
2.4.22 Providing & erecting weather proof, dust & vermin
proof, floor mounted front operated indoor type
cubical panel board necessary IP-42 and above
protection as per approval from engineer
incharge made from 14 SWG thick CRC M.S.
sheet for outer body & doors, 16 SWG thick CRC
M.S.sheet for internal partitions with necessary
accesories , supporting angles/ flats channel
including cutting, bending, drilling, welding,
riveting with internal partitions & cable alley as per
requirements & instruction of engineer-in-charge
with erection of
supplied switch gears, BUSBARS, suitable size
of inter connecting PVC copper wire / copper-
aluminium strips, rubber grommets, rib, bakelite
control fuses/MCB for measuring instruments,
earth bus & earth bolts, foundation flange - bolts-
base Plates, sufficient nos. of hinged doors,
handles with locking arrangement and rubber
gasket,heavy duty end terminal
connection,danger notice board,necessary
ventilation,earthing strip complete. The Panel
shall be painted with epoxy powder coating.
(The rates excludes the cost of switchgears, bus
bars, inter connecting mains & Copper Aluminium
strips, meters, Fuses etc. The dimension shall be
measured excluding base beams) The panel shall
be supplied with following approved
manufacturers with following size.
(B) The standard companies switch gear shall be
used and only manufacturers at CPRI approved
2.5 (i) with 350mm depth 14755 Sqmtr
2.4.23 Supplying & erecting XLPE(IS:7098)(I)-88 ISI
unarmoured copper cable 1.1 KV grade to be
erected as directed of following size.
2.4.23 16 (N) 4 core 16 Sq. mm 721 Mtr
2.4.23 12 (M) 4 core 10 Sq. mm 568 Mtr
2.4.23 2 (L) 4 core 6 Sq. mm 361 Mtr
2.4.23 50 (C) 2 core 6 Sq. mm 202 Mtr
2.4.23 4 (B) 2 core 4 sq.mm 130 Mtr
2.4.24 providing and erecting Mains with ISI marked,
1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC
insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for
control panel, relays, power switchgears, motor
starters & control wiring) with required size of
copper lugs, nuts and bolts if required.
2.4.24 40 (a) One wire 1.00 sq. mm 12 Mtr
2.4.24 95 (b) One wire 1.50 sq. mm 17 Mtr
2.4.24 36 (c) One wire 2.50 sq. mm 27 Mtr
2.4.25 1 Design, fabrication, assembling, supply, 57615 No
installation, testing and commissioning of cubicle
type,15KVAR, Voltage Rating 415V A.C.,3-Phase
, APFC Panel having 5-steps ( 2-3-5--5 kvar
heavy duty can type capacitors ) with suitable
rating of Incomer MCB, CT. as per approved by
engineer incharge.
2.4.26 Supplying & erecting approved make IP 55 grade
Company fabricated Timer Panel of following
capacity for switch On-Off street lights on time
scheduling basis made from 16G CRCA sheet
duly epoxy power painted inside and outside with
hinged doors and locking arrangement consisting
of suitable size of 4 Pole MCB and 4 pole
contactor (cat-III)with analog time switch, auto
manual switch of same make and suitable input
and output Bakelite terminals and with door
earthing approved by Engineer in charge.
MCBDBs and MCBs
2.5 150 providing and erecting Miniature circuit 111 E.a.
breaker single pole 6A to 25A suitable to
operate on 240 V A.C. system and having
breaking capacity 10 KA to be erected in existing
box. confirming to IS 8828/1996 with ISI Mark
2.6 Providing & erecting 240 V MCB double pole
switch for motor & inductive load (C Curve)
having 10 KA breaking capacity & confirms to IS :
8828 in existing box having following capacity
2.7 Providing & erecting 415 V MCB Four Pole for
Motor & Inductive Load (C Curve) having 10KA
breaking capacity & confirms to IS :8828 in
existing box having following capacity
2.8 4 Sheets steel powder coated enclosure suitable 175 E.a.
for incorporating One/Two nos. MCB.
2.9 Providing and erecting Sheet Steel powder
coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link, earth bar
and DIN rail, Conforms to IS 8623-1 & 3, IEC
61439-1 & 3 without MCB to house appropriate
nos. of MCBs.(The DBs should be used of same
company of MCB to be used) suitable for
(A) single phase incoming and horizontal
single phase outgoing
(b) sheet steel double door (IP-43)
2.9.1 6 (i)4 way ( concealed manner ) 747.60 E.a.
2.9.3 4 (iii)8 way ( concealed manner ) 1369.20 E.a.
2.9.5 4 (iv)12 way ( concealed manner ) 1773.60 E.a.
2.9.7 5 (v) 16 way ( concealed manner ) 1996.8 E.a.
2.10 (B) three phase incoming and single phase
horizontal type outgoing Per phase isolation
(b) sheet steel double door
2.10.1 3 (i)4 way ( concealed manner ) 2779.20 E.a.
2.10.3 1 (ii)6 way ( concealed manner ) 3462 E.a.
2.10.5 3 (iii)8 way ( concealed manner ) 4054.80 E.a.
2.11 Supplying & erecting Sheet Steel powder coated
Cable end termination Box to be mounted on
Top or Bottom of the MCB Distribution Box for
housing/covering Extra wires & Cables, suitable
for following size of MCB DB Box.
2.11.1 2 (G) Three Phase 8 Way ( concealed manner ) 819.60 E.a.
2.11.2 2 (G) Three Phase 8 Way 683 E.a.
2.12 providing and erecting Approved make ELCBs /
RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand
capacity of 10 KA and suitable for operation on
single phase 240 V,50Hz. having characteristic of
quick action & tripping with all advance feature &
do not incorporate any electronic component. for
following Max. rating erected as directed
2.12.3 7 (iii) 63 Amps. DP 2628 E.a.
2.13 15 Providing and erecting metallic vitrified danger 69 E.a.
notice board as per language suggested by
engineer incharge for MEDIUM VOLTAGE
installation to be erected as per IS-2551.
2.14 15 Providing & erecting Medium Voltage Danger 26 E.a.
Notice Board sticker as per language
suggested by engineer incharge of standard
size as per IS-2551
SUB - TOTAL OF Switchgears , Panel and
Follow IS code :3043 is the guideline for the
3.1 160 Providing and erecting required size HOT deep 77 KG
Galvanised iron strip for earthing of H.T. , OCB/
ACB/ Transformer LT panel board, Motors etc.
using proper clamp.
3.2 20 Providing and erecting required size Copper strip 787 KG
for earthing of H.T. OCB / ACB/ Transformer, LT
panel board, Motors etc. using copper clamp.
3.3 10 Providing and erecting Annealed bare Copper 787 KG
wire 8 to 16 SWG.
3.4 45 Providing and erecting HOT deep Galvanised 77 KG
iron strip wire 8 to 16 SWG.
Supplying & erecting earth pit of minimum bore
dia.150mm size approved make Earthing
Electrode consisting Pipe-in-Pipe Technology
as per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 50mm
having 80-200 Micron galvanising, Inner pipe dia
of 25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant
ohmic value surrounded by highly conductive
compound with high charge dissipation suitable
for following type of applications with chamber
and heavy duty cover.(approved make OEM has
to submit test certificate) & having back filling
compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 W/ meter testing as
per IEC 62561-2017, Voltage drop:- < 1 volt at no
load & dry form, Sulphar content:- <2%(C) Back
fill Compound :- Earthing compound should be
capable to retain moisture for long time
Necessary test report must be submitted.
3.5.1 3 (a) For Electrical Installation up to 440V in normal 4546 E.a.
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
3.5.2 1 (c) For Electrical Installation covering Transformer 8551 E.a.
Neutrals, Lightning arrester Earthing, A.C.Plant &
Sensitive Computer System(like Automation,
SCADA) i.e independent Earthing in normal soil.
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of 25 Kg.
3.6 3 Supply, installation,testing and commissioning of 12230 No
Chemical Earthing with UL Certified 17.2mm Dia.
X 3000mm Long 254 Micron-Copper bonded M.S.
Rod manufactured as per IEC 62561-2 with 25Kg
Bentonite powder plus " U " bolt rod clamp
complete with Lockable high performence
chamber suitable & tested for 5000T capacity
with SS Hardware.or equivalent
SUB - TOTAL OF Earthing
4.0 CABLES, Cable Termination and cable
4.1 Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables
4.1.3 65 (D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core) 375 Mtr
4.1.4 70 (E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core) 486 Mtr
4.2 Providing and erecting XLPE (IS:7098)(I)-88 ISI
armoured cable multistrand / Solid Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables
4.2.1 55 (a) 4 core 4 Sq. mm 116 Mtr
4.2.2 300 (b) 4 core 6 Sq. mm 125 Mtr
4.2.3 80 (c) 4 core 10 Sq. mm 139 Mtr
4.3 Providing and erecting XLPE (IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of
following size of cables
4.3.1 80 (d) 4 core 16 Sq. mm 152 Mtr
4.3.2 15 (e) 4 core 25 Sq. mm 189 Mtr
4.4 Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
1.1 KV. to be laid on wall with necessary clamps
or in existing trench / pipe at road crossing or
floor of following size of cable.
4.4.1 65 (C) 3 core 6 Sq. mm 392 Mtr
4.4.2 25 (D) 3 core 10 Sq. mm 495 Mtr
4.5 Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand / Solid Copper
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe at
road crossing or floor of following size of cables.
4.5.1 30 (A) 4 core 2.5 Sq. mm 269 Mtr
4.5.2 30 (B) 4 core 4 Sq. mm 361 Mtr
4.5.3 50 (C) 4 core 6 Sq. mm 505 Mtr
4.6 Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe at
road crossing or floor of following size of cables.
45 (C) 4 core 10 Sq. mm 670 Mtr
4.7 300 Making trench in soft soil of suitable width of 90 55 Mtr
cm deep for laying cable or locating the fault all
over the run and back filling the same and making
the surface as normal ground.
4.8 260 Covering of cable with second class bricks or 139 Mtr
cement tiles laid cover the cable crosswise & also
on both sides with covering of 7. 5 Cm. layer of
sand above & below cable (16 bricks per meter)
4.9 10 ( A )Making trench in Hard Murrum / Tar Road of 74 Mtr
suitable width of 90 cm or required depth for
laying any size of cable or locating the fault all
over the run and back filling the same and making
the surface as normal ground.
4.10 5 (B) If additional machinery like hammer driller or 354 Mtr
4.11 Drilling the road without breaking the road
surface (Asphalt) for laying of cable for feeding
power supply by making up to following size of
holes at both ends complete.
4.11.1 5 (A) Up to 100 mm bore dia 488 Mtr
4.11.2 5 (B) Up to 150 mm bore dia 610 Mtr
4.12 Supplying following size of Light duty “A”
Class G.I . Pipe & erecting as directed by
Engineer-in-charge.
20 (A) 25 mm dia 171 Mtr
4.13 Providing & laying. R.C.C. Hume pipe for cable
to be laid 90 cm. below ground across the road
crossing or on floor with necessary material in an
approved manner and making the ground as per
4.14 Providing & laying approved make Double
walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same
material at required depth in existing trench for
laying of cable. below ground / road surface for
enclosing cable
4.14.1 50 (A)50 mm outer dia 62 Mtr
4.14.2 300 (B)63mm outer dia 73 Mtr
4.14.3 10 (C))90 mm outer dia 95 Mtr
4.14.4 50 (D)120 mm outer dia. 136 Mtr
Providing & laying approved make ISI marked
Rigid PVC pipe having 6Kg / cm2 (Class-3) to
be erected at road crossing on or floor as directed
for laying of cable. The pipes as following size of
dia & weight per 6 mtr.
4.15.1 5 (D) 75 mm inner Dia. (5.5 Kg/6RMT) 124 Mtr
4.15.2 5 (F) 110 mm inner Dia. (11.63 Kg/6 RMT) 234 Mtr
4.16 Providing and, fixing heavy duty flange type
brass cable gland with rubber ring for PVC
insulated armoured cable complete with out going
tails, insulating tape etc for following size of
4.16.2 30 (b) 2 to 4 core 6 Sq. mm 38 E.a.
4.16.3 5 (c) 2 to 4 core 10 Sq. mm 38 E.a.
4.16.4 6 (d) 2 to 4 core 16 Sq. mm 47 E.a.
4.16.5 4 (e) 2 to 4 core 25 Sq. mm 51 E.a.
4.17 Providing and, fixing heavy duty flange type
brass double compression type cable gland
with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc
for following size of cables.
4.18 Solder less crimping type Aluminium lugs
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
4.19 Solder less crimping type Copper lugs
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
4.20 Providing and fixing approved make Perforated C
type cable tray. Made from sheet steel. The
cable tray should be single or double bended as
per required and as per IS 2062/1079 and shall be
coated with hot dip galvanizing as per IS
2629/4759. with max 17.5% perforation with
coupler plate / Fish plate and GI hardware like nut
- bolt and washers etc. erection with necessary
support( included) as per Specification and as per
instruction of engineer in charge..
SUB - TOTAL OF Cables,Cable
Terminations & Cable Trenches
5.0 Light Fixtures & Fans
Supply , Installation, testing and commissioning of
pre-wired, LED fitting/post top luminaries etc of all
types, complete with all accessories and tube etc.
directly on ceiling/ wall, including connection with
1.5 sq. mm FRLS PVC insulated, flexible, copper
conductor, single core cable with flexible conduits
and coupler and earthing etc. as required. Note:-
The LED Light fixtures should comply all
international standards third party ( LM 79 for
complete fixture, LM 80 for individual LED ).
The Manufacturer / Channel Partner of the
Manufacturer has to submit 4- Years
unconditional free Replacement Guarantee for
complete fixture.
5.1 Supplying and erecting LED indoor fittings with
LEDs of wattage 0.2 Watt to 0.5 Watt assembled
on single MCPCB, with housing used as a heat
sink shall be made of thick sheet Steel conforming
to IS: 513/CRCA/ aluminium die cast powder
coated and high U.V. & corrosion resistance with
diffuser with company mark/name 160V to 270V,
Power Factor more than 0.95, THD < 15%,CCT
3000 K to 6500K, Luminaire efficacy>
lumens/watt , LED driver efficiency > 85 %( fitting
required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the
5.1.1 ( A ) Tube Light with integral / non integral
5.1.1a 2 (iii) 18-20 Watts, Surge - 2KV,IP-20, conventional 293 No
5.1.1b 35 (v) 36-40 Watts, Surge-2 KV, IP-20, conventional 530 No
5.1.2 (B) LED Panel Light with provision for Plane front
frame with translucent cover fixed to housing
5.1.2a 4 (i)up to 8 Watts,4" x 4", Surge-2 KV 271 No
5.1.2b 75 (iii) 12-15 watts, 6" x 6", Surge-2 KV 462 No
5.1.2c 100 (iv) 18 to 20 watts, 8" x 8", Surge- 2 KV 607 No
(vi) 36 watts, 24" x 24", Surge- 2KV
5.1.3 (G) Spot Light 425 Lumens, Surge-2KV
5.1.3a 8 (a) 3 to 7 Watts 805 No
5.1.3b 8 (b) 8 to 11 Watts 1354 No
5.1.4 7 (H) Mirror Light 9 Watts, wall mounted minimum 1 309 No
5.2 45 Providing & erecting Approved make Power 1929 No
Saving 50 Watt Ceiling Fan with double ball
bearing ISI mark with Condenser 230 volt A.C.
50 Hz 1200 mm sweep complete having 3blades
with aluminium blades with , canopy & 30 cm.
down rod erected with earthing.(Make shall be
approved by Engineer in charge))
5.3 5 Providing & erecting Approved make Ceiling Fan 1721 No
with double ball bearing ISI mark with condenser
A.C.230V 50c/s. 1400 mm. sweep complete,
canopy erected on existing hook or clamp with
earthing [ Make shall be approved by Engineer in
5.4 2 Providing & erecting Approved make Ceiling Fan 1963 No
with double ball bearing with Condenser 230 volt
A.C.50 Hz. 900 mm sweep complete having
Aluminium blades, canopy erected complete. [
Make shall be approved by Engineer in Charge]
5.5 1 Supplying and erecting approved make oscillating 2329 No
type medium duty bracket fan with Aluminium
Blades A.C. 23OV. 50cy/s wall mounted with
height adjustment and rotary tilting device
complete with guard, mounting accessories kit,
pull cord for speed and oscillation flexible Core
plug top complete erected with lead wires as
directed. 400MM.
5.6 15 Supplying & erecting approved make low noise 1687 No
decorative exhaust fan having size 200mm with
1350 RPM with square frame ABS body with
inbuilt lowers & square frame.
Supplying & erecting fan hook box of 10 mm
M.S. round bar bounded to the RCC bars up to
50mm length each side and pierced through a
Gauge M.S. box / Heavy Duty PVC box complete
erected concealed in Ceiling with necessary
5.8 55 Providing 2.5mm.thick laminated acrylic sheet to 18 No
cover the fan hook or Fan box.
5.9 55 Supplying and erecting 19 / 20 mm. nominal 107 Mtr
bore Medium Class M.S. Pipe down rod erected
duly painted for fan complete with proper
insulation without leakage and earthing.
5.10 Supplying & erecting single phase approved
make industrial exhaust fan suitable for medium
duty ring mounted low noise operation suitable for
medium duty having following dia size and
maximum speed in RPM
1 [D] 450 mm dia 900 RPM 3306 No
5.11 1 Providing suitable M.S. louver shutter of the 365 No
5.12 1 Supplying & erecting electro galvanised G.I. 628 Sqmtr
wire micro mesh jali cover of grade
required size with suitable wooden frame duly
fitted in wall outside of exhaust fan for insect
Providing and erecting PVC body surface or
pendent mounting LED Bulk type 9 watt Lighting
Fitting with electronic driver. And lumen output
from luminaire 720lm , input voltage range 90-
300VAC , 50Hz cool white(3000 to 6500k), inbuilt
driver, -20degC to +60degC working temperature,
AL frame with Beam Angle 120deg
SUB - TOTAL OF Light Fixtures & Fans
6.0 External lighting
Supply , Installation, testing and commissioning of
pre-wired, LED fitting /post top luminaries etc of all
typesof external lights, complete with all
accessories and tube etc. directly on pole / pole
bracket , including connection with 1.5 / 2.5 sq.
mm FRLS PVC insulated,3 core flexible, copper
conductor, with flexible conduits and coupler and
earthing etc. as required.
6.1 Supplying and erecting LED street light / Flood
light fittings with High power White LEDs wattage
of 3 Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and
corrosion free High pressure die cast aluminum
housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened
glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than
5700K,Uniformity ratio >0.45, Luminaire efficacy>
100 lumens/watt . LED driver efficiency > 85 %.(
fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage
capacity between the ranges shown.)
6.1.1 (A) Street Light (IP-65), Surge protection -4KV
/5000K integral and 10 kv non integral ,Light must
have 440VAC line supply protection. It should
withstand 48 hours for 440VAC line supply.
11 (f) Above 60 watts to 90 watts 5917 No
(B) Flood Light (IP-65), Surge -4KV/5000K ,Light
must have 440VAC line supply protection. It
should withstand 48 hours for 440VAC line supply
6.1.2a 2 (c) Above 60 watts to 90 watts 6028 No
6.1.2b 2 (v) above 120 to 160 watts 8370 No
6.2 Supply of approved make frp/grp pole having
followiing specifications :
FRP/GRP pole made by centrifugal moulding
process using thermoset resin polyester/epoxy
resin system having minimum glass content
45.0%.The pole should be in one pieceand
tapered round in shape,having smooth outside
surface finish and should be totally fre from
corrosion as well as non conductive and shock
proof. Pole should be provided with FRP/GRP
base bracket dully fabricated from metal(M.S) and
dully claded with FRP/GRP material to avoid any
metal exposer and painted with PU paint.Pole
should mechanical properties i.e 1. Specfic gravity
(ASTM D 792) 1.3‐1.8 Kg/m3, 2. Glass Content %
by weight (ASTM D 2584) 45.0 ‐55.0%, 3. Water
absorption (ASTM D 570) <0.5%, 4. Tensile
Strength(ASTM D 638) 200+/‐50Mpa, 5. Flexural
strength (ASTM D 790) 250+/‐50Mpa,
Compressive Strength (ASTM D 695) 200+/‐
50MPa, 7. Yeild Strength(ASTM D638) 250 +/‐
Pole should be flame retardant as per IS
6746.Resin used shall be UV resistance and
pigmented. Pole should be painted with first coat
of epoxy primer and then two coat of highly
weather resistance polyurethen paint to ensure
proper addhesion of the paint.Minimum thickness
shall be 80 to 100 micron.Defelection of the pole
shall not exceed more than 10.0 % of the length of
the pole for the given load.Pole should be
generally made as per the dimensional
data,performance criteria and some
interchagebility features of poles as per the
standard ANSI C123.20 latest version of ASTM D
923/01 including cable termination box with
necessory accessories.The size of pole and type
of installation with foundation , Anchor Base &
Internal junction box as per the manufacturer
details and site requirement .
(3) 'B' class (Heavy Duty) frp/grp pole suitable
for base plate mounting
[D] Overall Length of 6.0 meter, Average
thickness : 7mm, Top/Bottom Outside Dia.
76/176mm +/‐2.Weight of Pole 25.0 Kg approx.
(Without base) Metal Anchor Base dully frp claded
(Size : 340 Ø * 12mmthk , Mounting hole PCD
285mm * 6 nos. of 20 Ø hole)
6.3 Providing FRP/GRP arm bracket of having 15˚
arm with 50 mm OD pipe *5 mm thk,1000mm long
from pole centre
6.3.1 9 (a) Single arm bracket 1882 No
6.3.2 1 (b) Double arm bracket 2390 No
6.4 4 Supplying & erecting sintex make SMC press 472.00 No
moulded composite FRP. loop-in, loop-out
approx. 2mm thick box complete with bakelite
connector strip 4way & hinged doors having
locking arrangements with mounting clamp with
nuts, bolts & washers suitable for erection on wall
( c)150mm x 125mm x 100mm [deep].
6.5 4 Providing cement concrete.for foundation or 5077.00 CU Mtr
for concrete filling in 1:2:4 ratio with 20 to 25 mm
stone metal duly plastered with necessary curing
for pole muffing or any other purpose.
B' class galvanised iron pipe 32 mm outside dia
45 cms long duly welded on 20 cms x 20 cms x
mm thick M.S. base plate, erected on wall or
corner for mounting street light luminaire with
necessary hardware materials duly painted.
SUB - TOTAL OF External Lighting
7.1 1 Supplying & erecting approved make Automatic 2332 Job
liquid level controller 6A. with sensor testing
as per instruction of Engineer in charge on site
complete with wiring connection with existing
wires , with copper conductor from pump to upper
and lower tank.
7.2 Supplying and erecting Flexible PVC insulated
multistrand multicore 1.1 kv grade ISI marked
copper wires of following size to be erected as
90 e) 1.50 Sq.mm 3 core round PVC sheathed 46 Mtr
7.3 Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete to
be erected on/in wall or ceiling erected with
necessary PVC fittings & Junction boxes fixed
with adhesive solution & Clamps with following dia
of pipes, in approved manner as directed .
Providing & erecting water cooler having storage
capacity 150 Ltr. & cooling capacity 150 Ltr.per
hour @ an ambient temp of 45˚ C. The outlet
temp. of the water should drop by 15˚C within a
hour, The water cooler should be comprising of
hermetically sealed compressor, fan motor,
condensing unit, water tank surrounded by
evaporating, coil, thermostats, relay etc.complete
with necessary inlet & outlet connection. The body
of water cooler will be made from Stainless Steel.
Supplying and erecting water filter cum purifier
with ultra violate technology. (Aquaguard /
waterdoc model or equivalent symphony/
crystal/videocon model)
7.6 Providing & erecting open well horizontal mono
block pump set with cast iron body, complete for
three phase submersible motor having
7.6.1 2 [B] For 2 HP 3 phase open well horizontal mono 10628 No
block pump set suitable for 200 LPM @ 25 mtr
head suitable for 50 mm dia delivery pipe
[C] For 3 HP 3 phase open well horizontal mono
block pump set suitable for 85 LPM to 270 LPM
@ 11 mtr to 33 mtr head suitable for 50/65 mm
dia delivery pipe
Supplying & erecting approved make motor
control cubical panel (Direct - on - line) made
from 16 G. CRCA sheet duly epoxy powder
painted inside and outside with hinged doors and
locking, arrangement consisting of suitable size of
ON- OFF isolator (AC - 3/23duty) main fuses,
single phasing preventer, indicating lamps for R-
Y - B phases, overload relay, Automatic water
level controller, Ammeter, Voltmeter each with
two way selector switch incoming, wires duly
socket crimped, main contactor & overload relay,
start - stop push buttons, to be erected on angle
iron frame grouted on wall as directed. The
isolator, overload relay & contactors will be of L &
T, Siemens or BCH make only.
2 (a) DOL up to 5.0 H.P. 7646 No
7.8 1 Charges for doing liasioning work for obtaining the 20500 No
necessary clearances from the Electrical inspector
/ competent Authorities for the total Electrical
installation,co-ordinating with various agencies. All
necessary drawings, calculations, test certificates,
etc. as required by these authorities shall be
prepared and furnished by the EPC Vendor. Any
modification/rectification as required by these
authorities shall be carried out by theEPC Vendor
at free of cost. The fees required to be paid to
these authorities for inspection shall be borne by
Owner on production of documentary evidences.
7.9 online Un-interruptible Power Supply
Supplying and erecting approved make online
Un-interruptible Power Supply system comprising
flat cum-boost charger with IGBT base rectifier &
Inverter & sealed maintenance free SMF
batteries. The charger having operating capacity
for input 160-270V AC & inverter having output
230V,50 Hz Ac with 0.8 load power factor with
battery, over/under voltage output with over load
& short circuit protection equipment. The system
housed in CRC sheet duly powder coated paint
with following power backup.with MS painted
batteries stand, 10% Overload capacity for
momentary load.
7.9.1 1 (C) 3 KVA with 1Hr Backup 82120 No
7.9.2 1 [E] 6 KVA with 1Hr Backup 177211 No
7.10 Providing and erecting approved make split air-
conditioning unit consisting of copper condensing
unit with fan motor, hermetically sealed rotary
compressor with accessories etc. duly connected
separately erected evaporating unit and blower
motor with its accessories by means of extra
supplied proper insulated copper tubing,drain
PVC pipes suitable for ( cost includes powder
coated Stand, Eco Friendly green gas charging,
15A plug top & Remote Control) with necessary
(1)For ISEER Range (KWH/KWH)(3.1 to 3.99)
7.10.1 1 [a] For 1 Ton Capacity 30409 No
7.10.2 1 (b) for 1.5 ton capacity 36455 No
7.10.3 3 (c) for 2 ton capacity 45830 No
7.11 Supplying and installing MS angle , powder
coated / Painted standard type of wall/floor stand
mount for outdoor unit of split AC of following
capacity, erected with necessary hardware
materials as directed.
4 (A) 25mm*25mm*3mm thick M.S angle suitable 1305 No
for upto 2 TR. Capacity of ac machine
7.12 45 Supplying and erecting insulated pair of soft 956 RMT
copper tubing including power and control
cable,necessary PVC drain pipes for Split AC
machine up to 4 TR capacity
Rigid UPVC drain pipe of 10 Kg/cm2. rating with
mm thick.nitrile rubber insulation.
SUB - TOTAL OF MISC. Work
8.0 PASSENGERS ELEVATOR
Supply ,installing , commissioning and testing of
M.R.L. Passengers Elevator 8/10 passengers
as per R & B S.O.R ( Category - Premium )
having following specifications:- G+2 Upper
Supplying, Erecting, Testing & Commissioning the
passenger lift having following main features:
[1] GEAR LESS LIFT DRIVE comprising of High
Starting torque Lift 3 phase 440 V
A. C. Permanent Magnet Synchronous motor of
proper rating with high efficiency shall be used.
[2] Micro processor based / PLC, ACVVVF, vector
control drive with encoder feedback closed loop
system shall be used for lift car and door
operation which shall be full collective selective
operation hall call demand response, UP/DOWN
hall stops, Main, Up/ Down Contactor with
overload and phase reversal relay and safety
[3] Car with M S platform with bracings of
adequate size and to sustain the impact load
cabin + passenger with safety factor of fire for
steel and side panels of Stainless steel of sheet of
grade 304 duty. Car ceiling will be S.S. finishes
with aesthetic appearance with LED ceiling lights.
Car flooring shall be of anti skid PVC with choice
of colour of engineer in charge. Car doors shall be
of stainless steel grade 304, hairline finish with
centre opening / telescopic automatic doors. Car
panel will also be S.S. 304 finished with
emergency stop device, mechanical door safety
device, facility of auto/ attended mode. All car
panel buttons and all floor switches must be with
brail language as per lift act.
[4] All landing doors must be fire rated for 2 hour
shall be fully automatic centre opening/ telescopic
opening made of hairline finish steel grade of
with key holes and infrared curtains with
Unlocking facility from outside
[5] Appropriate battery operated emergency light
in the car along with alarm switch shall be
provided. Also, Emergency Light & Fan should
start immediately without any Time Delay as soon
as power fails.
[6] Digital scrolling indicator system for up-down
arrow along with floor position indicator shall be
provided inside the car and at all floors.
[7] Full height infra red curtain with multiple cross /
crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be
provided accordingly of passenger capacity with
Manual Rescue Operation ( Manual Cranking
[9] Audio visual indication in the lift car showing
over loading shall be provided such that doors
kept open till excess load is removed.
[10] Spring buffers/PU Buffers shall be provided.
[11] Car fan as per passenger capacity with
automatic sleep timer shall be provided.
[12] Voice annunciator with suitable music shall
be provided in lift car.
[13] Self diagnostics system for operational and
safety parameters shall be provided in control
[14] Mechanical over speed governor with
governor calibration as per actual site parameters
and submission of calibration certificate
submission, door key holes in the floor doors,
fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the lift
machine room and monkey ladder for lift pit
should be provided by the lift agency, along with
the other steel structure works, foundations for the
[16] In the hoist way fascia plate shall be provided
without any extra cost, where ever required as / if
directed by engineer in charge.
[17] Permanent wiring with necessary safety
devices like RCCB in all circuit, Over Voltage
Under Voltage protection and THD eliminator in
circuit for lift machine room and lift well with
proper numbers of light points, with fixtures,
exhaust fan and plug points shall be provided by
the agency. Only 3 phase Power Supply shall be
made available by department in lift machine
room. Necessary Earthing as per Lift Act/Rules
shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional and
alteration in lift shaft and machine room related to
erection of lift shall be made by lift agency without
any extra cost. (granite/marble fixing around all
landing door openings are not in lift agency’s
[19] Agency has to provide all working drawings
and documents and liaison services for obtaining
all necessary permission from lift inspector and
other authorities.
[20] acrylic transparent licence/display A4 size
holder in lift car
[20A] As per statutory requirement of Govt. Of
Gujarat lift & escalator act 2000, lift agency has to
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection
during/after lift erection and provide report by
third party authorized by concern licensing
authority 5.agency has to provide third party
insurance upto completion of free maintenance
period and submit the document for the same.
[21] Car Panel Operating Buttons with floor
position indicator/buttons must be of Auto Glow
type clearly visible when view from inside cabin.
[22] For Physically Handicapped person Full
Length Handrails of hairline finish steel grade of
304 should be provided at appropriate height on
the Rear & Side Wall Panels in Lift Car.
[23] With Necessary KVA rating voltage
controlled Stabilizer suitable for your
controller, drive and all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb
required for lift is in scope of work which
rating is sugested by CEICED Department
(electrical Inspector)
(B) SPECIAL FEATURES DESCRIPTION OF
LIFTS for PREMIUM category
1. Advanced control system dual 64 bit
embedded microprocessor with CANBUS Serial
Communication mode including Regenerative
power efficient operation,on site programming
facility, Anti nuisance, Pte-opening, BMS/RMS
with necessary online real time monitoring system
having necessary connectivity for remote
monitoring & other suitable supporting hardware
& software devices to fulfil the purpose.
2. Floor Indication LCD Display with call
registration & brail mark with arrival gong and hall
lantern & TFT Screen in the car with MP3 Voice
3. CAR Panel should be Scratch resistive SS
Moonrock finish / Hair Line / Honeycomb for car
and all Doors, All landing doors must have fire
rating up to 2 hours and car door must have multi-
level crisscross beam door protection.
4. To & fro communication system & wiring (i.e.
car , control room & guard room ) and Each
elevator are equipped with remote monitoring
system.agency has to provide mobile app and
user id and password for monitoring
8 / 10 Passengers, Ground plus 3 upper floor
with Rated Speed of 1.0 m/sec.,
1 (C) With General PLUS ADDITIONAL SPECIAL 1460178 E.a.
FEATURES attached herewith. Prem. Cat.
SUB TOTAL of Passengers Elevator
9.0 COMPREHENSIVE Maintenance
Annual Comprehensive Type Maintenance
Contract of ELECTRICAL + HVAC System and
passenger Elevator For 1-Year DLP + ONE
9.1 1 Annual comprehensive Type Maintenance FREE Year
Charges only During Guarentee / Defect
Liability period.
9.2 1 Annual comprehensive Type Maintenance 111767.9 Year
Charges for 1st Year after Guarentee /
Defect Liability period.
SUB-TOTAL Of ANNUAL Comprehensive
Maintenance contract Of Electrical
/HVACand passenger Elevator
FIRE FIGHTING SYSTEM
Unit Rate Amount
I. No. Qty Items Per
FIRE FIGHTING SYSTEM
Design,Drawing, Supply,installing,testing
and commissioning of FIRE HYDRANT
Internal / External Hydrant
1.1.1 Supplying, Installation, Testing and
Commissioning of electric driven main Hydrant
fire pump and Sprinkler pump suitable for
automatic operation and consisting of following:
complete in all respect as required.
1.1.1 1 a) Horizontal type, single stage, centrifugal, end 230151 Set
suction pump of cast iron body & bronze impeller
with stainless steel shaft, mechanical seal to
ensure a minimum pressure of 3.5 kg/sq. cm. at
highest and farthest outlet at specified flow of
2280 lpm at 65 Mtr. head conforming to IS
1520.with suitable size of footvalve confirming to
IS 4038, Pressure rating PN2 , preventing entry of
foreign body to pump through suction pipe,
perfectly flat seating surfaces for good sealing.
b) Suitable HP Squirrel cage induction motor,
TEFC, suitable for opertion on 415 volts, 3 phase
50 Hz. AC with IP 55 class protection for
enclosure, horizontal foot mounted type with
Class - 'F' insulation, conforming to IS-325.
c) M.S. fabricated Common base plate, coupling,
coupling guard, foundation bolts etc. as required.
d) Suitable cement concrete foundation duly
plastered with anti vibration pads.
The pump shall be capable of giving not less than
150% discharge at ahead not less than 65% of
the rated head.
1.1.2 1 Supplying, Installation, Testing and 61717 Set
Commissioning of electric driven pressurisation
pump suitable for automatic operation and
consisting of following: complete in all respect as
a) Horizontal type, single stage, centrifugal, end
suction pump of cast iron body and bronze
impeller with stainless steel shaft, mechanical seal
at specified flow of 180 lpm at 56/70 m. head
conforming to IS: 1520.with suitable size of
footvalve confirming to IS 4038, Pressure rating
PN2 , preventing entry of foreign body to pump
through suction pipe, perfectly flat seating
surfaces for good sealing.
b) Suitable HP Squirrel cage induction motor
TEFC type suitable for operation on 415 volts,
phase 50 Hz. AC with IP 55 Class of protection for
enclosure, horizontal foot mounted type with
Class F' insulation, conforming to IS :
c) M.S. fabricated Common base plate, flexible
rubber coupling, coupling guard, foundtion bolts
etc. as required.
d) Suitable cement concrete foundation duly
plastered with anti vibration pads.
1.1.3 ENGINE DRIVEN PUMP
1.1.3A 1 Supplying, Installation, Testing and 506181 Set
Commissioning of diesel engine driven main fire
pump suitable for automatic operation and
consisting of following: complete in all respect as
a) Horizontal type, single stage, centrifugal, end
suction pump of cast iron body and bronze
impeller with stainless steel shaft, mechanical seal
to ensure a minimum pressure of 3.5 kg/sq. cm at
highest and farthest outlet at specified flow of
2280 lpm at 65 m. head conforming to IS
b) Suitable HP, 1500 /1800 RPM water cooled
with radiator, diesel engine conforming to
relevant BS & IS standard complete with auto
starting mechanism, 12/24 volts electric starting
equipment, 180 AH lead acid battery with battery
stand, exhaust pipe extended upto 6 m. outside
pump house duly insulated with 50 mm thick
glass wool with 1.0 mm. thick aluminium sheet
cladding, residential silencer, instruments and
protection as per specification, stop solenoid for
auto stop in the event of fault with audio
indications, painted with post office red colour etc.
c) One 200 Ltr capacity day oil storage tank
fabricated from 3 mm thick M.S. plates. Tank shall
be provided with inlet, outlet, overflow, air vent,
drain connections, filling connection & level
indicator. Tank shall be mounted on a suitable
steel structure (Painted with 2 coats of red oxide
paint). Tank shall be provided with two or more
coats of synthetic enamel paint outside over two
coats of red oxide primer.
d) M.S. Fabricated Common base plate, coupling,
coupling guard, foundation bolts etc. as required.
e) Suitable cement concrete foundation duly
plastered with anti vibration pads.
1 A. Incoming Feeder:- 259210 No
(i) 1 No of 200 A,35KA, 415V,FP MCCB with
Thermalmagnetic Based Releases having O/C,
S/C ,E/F protection, Digital ELR 96x96mm with
CBCT, FP Spreader Terminals 1 set= 8 Pcs,
Extended Rotory Handle for MCCB, 240V AC
Shunt Trip coil for MCCB.
(ii) LED type indicating Lamp with suitable rating
Amp SP MCB:- 1 Set (each set comprise of
(iii) Digital type 3 phase Multi function Meter with
suitable rating of MCB & 3 Nos. of single core
epoxy resin cast type CTs of 200/5 Amps, 10 VA,
CL 1.0 ratings -1 Set.
415 V, 200 Amps, FP Aluminium Busbars with
Heat shrinkable color code insulation sleeves.
OUTGOINGS:-( All outgoing feeders for pumps
should have digital Ammeter with selector
switches and LED type ON,OFF,Trip indicating
1 sets - 125 A, 25kA TPN MCCB, Ics=100% Icu,
with fully automatic Star/Delta starter suitable for
50 HP pump with overload protection, current
sensing type single phase preventor complete
with all acceessories and internal wiring required
for automatic operation,selector switch for
local/remote, auto/manual/OFF operation.
1 sets - 125 A, 25kA TPN MCCB, Ics=100% Icu,
with fully automatic Star/Delta starter suitable for
50 HP pump with overload protection, current
sensing type single phase preventor complete
with all acceessories and internal wiring required
for automatic operation,selector switch for
local/remote, auto/manual/OFF operation.
1 no.63A,16KA MCCB Ics=100%,Extended Rotry
handle with TM release having O/C & S/C
protection with 10 HP fully automatic star/ delta
starter , current sensing type, Single Phase
Preventer, ON/OFF Push Button & LED type
Indicating lamps complete with all accessories
and internal wiring required for automatic
operation, selector switch, for local/remote,
auto/manual operation
Diesel Engine Control.
Control for Diesel Engine comprising:
i) Auto/Manual selector switch & 3 attempt starting
device, timers and relays as required, push
buttons, start/stop in manual mode.
ii) LED type Indication lamp for High/Low Lub. Oil
pressure, High Water Temp and Engine ON
iii) Battery charger suitable for 12 V/24 V DC with
boost and trickle selector switch, 0-30 V DC volt
meter, 0-20 Amp DC Ammeter.
iv) All standard relays, accessories for automatic
operation of diesel engine, wiring with 1.5 sq mm
PVC insulated copper wire between various
sensors and system controller / starter, suitable
size cable for battery charging etc. as required.
System Controller
Designing, Supply, Installation, Testing and
Commissioning of system controller to control
operation of Main Electric Fire Pump, Diesel
Pump, Pressurisation Pump, Terrace Pump in
sequence as per specification consisting of relays,
timers, sensors, annunciation window for fault
indication, control wiring complete as
3 NOS. 25A DP MCB " C " Curve
1.3 PRESSURE GAUGES , Air vessel AND
1.3.1 3 Providing, fixing, testing and commissioning of 1329.87 Set
Pressure Switch with Needle Valve.
1.3.2 3 Providing and fixing in position the industrial 967.73 Set
type pressure gauges with gun metal / brass
valves complete as required
1.4 Providing, laying, testing & commissioning of 'C'
class heavy duty MS Pipe conforming to IS
1239 i/c fittings like elbows, tees, flanges, tapers,
nuts bolts, gaskets etc., in ground including
excavation and providing cement concrete blocks
as support, anticorrosive treatment with
coaltar/asphalt tape as per IS 10221, refilling the
trench etc. of following sizes complete as required
.( For HYDRANT )
40 100MM Dia 2300.63 Mtr
1.5 Providing, laying, testing & commissioning of 'C'
class heavy duty MS pipe conforming to IS
3589/IS 1239 including Welding, fittings like
elbows, tees, flanges,tapers, nuts bolts, gaskets
etc. and fixing the pipe on the wall/ceiling with
suitable clamp/support frame and painting with
two or more coats of synthetic enamel paint of
required shade complete as required :
1.5.9 5 200mm Dia ( wall thickness 6.3mm ) 4938.01 Mtr
1.6 Supplying and fixing Single headed internal /
External hydrant valve with 1 No. 63 mm dia
instantaneous FM Gunmetal/Stainless Steel
coupling and cast iron wheel,ISI marked,
conforming to IS 5290 (type A) with blank
Gunmetal/Stainless Steel cap and chain as
9 Single headed Stainless steel 5549.04 No
1.7 8 Providing, fixing, testing and commissioning of 10499.50 No
Wall mounting swing type first aid Fire Hose Reel
with drum, hanging bracket, 30 M x 25 mm dia
high pressure hose reel tubing as per IS:884 with
shut nozzle and ball valve and all required
1.80 8 Supplying, Installation, Testing and 4726.5 No
commissioning of weather proof Fire Hose
cabinet size 900x 600x300mm to house fire
hydrant & hose, including all other related
accessories fabricated from M.S. sheet (16
Gauge) of fully welded construction having front
door with locking arrangement, partially glazed
with 4 mm thick glass. Cabinet shall be powder
coated & painted with post office red colour
1.90 16 Providing ISI marked RRL (IS : 636, type‐A) fire 4020.55 No
hose pipe 15 meter long and 63 mm dia with ISI
marked (IS : 903) Stainless steel male and female
coupling bound and rivetted to hose pipes with
copper rivets and copper wire complete as
1.10 9 Providing Stainless steel ISI marked 63 mm. dia. 1502.28 No
male Instantaneous pattern short branch pipes
with 20 mm dia. Nozzle as per IS : 903, suitable
for 10 Kg/sqcm operating pressure and suitable
for interconnections to hose pipe coupling as
1.11 Supplying and fixing of fire brigade connection
of cast iron body with gun metal male
instantaneous inlet couplings complete with cap
and chain as reqd. for suitable dia MS pipe
connection conforming to IS
1 2 way - 100 mm dia M.S. Pipe 6094.09 No
1.12 2 Providing, fixing, testing and commissioning of 25 1949.25 No
mm dia Air Release Valve and Ball Valve
assembly on top of each riser for Air release
1.13 1 Providing, fixing, testing and commissioning 4940.68 No
Pressure Relieaf Valve 25mm dia with Ball Valve.
1.14 9 Supplying and fixing orifice plate made out of 6 1932.76 No
mm thick stainless steel (Grade 304) with orifice
of required size to be fitted between flange &
landing valve of external and internal hydrants to
reduce pressure at the outlet to the level of
kg/cm2 complete as required.
Supplying, fixing, testing and commissioning of
butterfly valve of PN 1.6 rating with
bronze/gunmetal seat duly ISI marked complete
with nuts, bolts, washers, gaskets conforming to
IS 13095 of following sizes as required :
1.16 Providing, installation, testing and commissioning
of non-return valve of following sizes confirming
to IS:5312 complete with rubber gasket, GI bolts,
nuts,washers etc.as required :
1.17 Providing, installation, testing and commissioning
of stainless steel Y-strainer fabricated out of
mm thick stainless steel, Grade 304, sheet with
mm dia holes with stainless steel flange.
Supply, Installation, Testing and Commissioning
of Brass. Ball Valves with all fittings required.
1.19 Supplying and erecting Flexible PVC insulated
multistrand multicore 1.1 kv grade ISI marked
copper wires of following size to be erected as
60 f) 1.50 Sq.mm 4 core round PVC sheathed 67 Mtr
1.20 3 SITC of fire pump start stop push buttons in box. 954.50 No
1.21 1 SITC of 2 Zone standalone Fire Alarm control 9300 No
Panel, 16X2 Character LCD Display, provision
for zone wise contact and sounder. Panel does
not have provision to connect Repeater Panel.
Make: Ravel Approval: CE Mark. (Including Five
year free maintenance with guarantee)
Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete to
be erected on/in wall or ceiling erected with
necessary PVC fittings & Junction boxes fixed
with adhesive solution & Clamps with following dia
of pipes, in approved manner as directed
60 (b) 25 mm 33 Mtr
1.23 3 Supply, Installation, Testing and Commissioning 1201.75 No
of Single action Manual Pull Station.Shock and
Vibration Resistant, pull Down Lever Remains
Down Until Reset. Shall be Polarity Insensitive
(with all mounting accessories , complete with
Junction Box for mooting on Surface, Cable lugs
at Ends, cable compression glands, cable tags
1.24 3 Supply, Installation, Testing and Commissioning 1201.75 No
of Conventional Sounder cum strobe having tone
settings with range of 95dbA and field selectable
15/30/75/110 candelas.(with all mounting
accessories , complete with Junction Box for
mooting on surface, cable lugs at ends, cable
compression glands, cable tags and Ferruling.)
CABLES AND TERMINATIONS
1.25 Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
1.1 KV. to be laid on wall with necessary clamps
or in existing trench / pipe at road crossing or
floor of following size of cable.
1.25.1 36 (B) 3 core 4 Sq. mm 285 Mtr
1.25.2 36 (G) 3 core 6 Sq. mm 392 Mtr
1.26 Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
1.1 KV. to be laid on wall with necessary clamps
or in existing trench / pipe at road crossing or
floor of following size of cable.
1.26.1 30 (D) 3 core 10 Sq. mm 495 Mtr
1.26.2 10 (E) 3 core 16 Sq. mm 720 Mtr
1.27 Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor
for 1.1 KV. to be laid on wall with necessary
clamps or in existing trench / pipe at road
crossing or floor of following size of cables.
1.27.1 25 (D) 8 core 2.5 sq.mm 315 Mtr
1.27.2 25 (G) 12 core 2.5 sq.mm 415 Mtr
1.28 Providing and, fixing heavy duty flange type brass
cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails,
insulating tape etc for following size of cables.
1.28.3 2 (D) 2 to 4 core 16 Sq. mm 47 No
1.29 Solder less crimping type Copper lugs conforming
to IS suitable for cable of following size evenly
crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated
nut bolts in an approved manner.
1.30 Providing and fixing approved make Perforated C
type cable tray. Made from sheet steel. The
cable tray should be single or double bended as
per required and as per IS 2062/1079 and shall be
coated with hot dip galvanizing as per IS
2629/4759. with max 17.5% perforation with
coupler plate / Fish plate and GI hardware like nut
- bolt and washers etc. erection with necessary
support( included) as per Specification and as per
instruction of engineer in charge..
1.30.1 10 (1) 50 X 50 X 1.6 mm Thick 302 RnMtr
1.31 1 Supply, installation,testing and commissioning of 12230 E.a.
Chemical Earthing with UL Certified 17.2mm Dia.
X 3000mm Long 254 Micron-Copper bonded M.S.
Rod manufactured as per IEC 62561-2 with 25Kg
Bentonite powder plus " U " bolt rod clamp
complete with Lockable high performence
chamber suitable & tested for 5000T capacity
with SS Hardware.or equivalent
1.32 2 Supplying, Installation, Testing and 19676.50 No
commissioning Sewage water submersible
pumping sets of CI casing & impeller, SS shaft,
including with inbuilt water level sensors for
operating the pumps automatically and all
accessories suitable for operation on 220 V-240
V, single phase, 50 Hz. AC supply etc. as reqd.
> 10 mm solid handling capacity,Minimum
Capacity - 50 LPM,Minimum Head >
1.33 1 Charges of Preparing Design , Drawings ,Testing 76271.19 job
of Fire Fighting System with necessary Approval
from Local Fire authority.( Including Pre-NOC and
NOC from Fire authority. )
1.34 Providing, fixing, testing and commissioning of
below Auto Glow Signages.
1.34.2 3 Fire Equipment: 4" X 12" 514.97 No
1.34.3 3 In case of Fire, do not use lift, use staircase: 8" x 650 No
1.34.4 3 Fire Lift 4"X12" 514.97 No
1.34.5 3 Fire Extinguishers 8"x 4" 480 No
1.34.6 3 Floor Sign": 4" X 12" 514.97 No
1.34.7 3 Fire Hydrant 4” X 12” 514.97 No
1.34.8 3 Fire Hose Reel.4” X 12” 514.97 No
1.34.9 3 DCP Extinguisher 8"x 4" 480 No
1.34.10 3 CO2 Extinguisher 8"X 4" 480 No
1.35 Providing, fixing, testing & commissioning of
15mm dia quartzoid bulb type sprinklers of rating
with required accessories :
1.35.1 65 Pendent Sprinkler 57°C standard response (K-80) 362.25 No
1.35.2 10 Pendent Sprinkler 68°C standard response (K-80) 471.50 No
1.36 Supplying, installation, testing & commissioning of
sprinkler flexible pipe (UL Listed) of stainless steel
complete with 15 NPT on reducer thread with
maximum working pressure of 175 PSI test
pressure of 875 PSI (Burst) with branch line (Inlet)
25mm NPT male thread to sprinkler head (Outlet)
15mm NPT female thread with reducer, nipple,
side brackets,center bracket, stockbar of following
sizes complete as required etc of following sizes
1.37 1 Providing fixing, testing and commissioning of 4939.25 No
Drainning & Testing Assembly 25mm dia with
Sight Glass , Union joint , Ball Valve & Drain
SUB-TOTAL OF FIRE HYDRANT System
2.0 FIRE EXTINGUISHERS AND LIGHTNING
2.1 FIRE EXTINGUISHER
2.1.1 3 FIRE EXTINGUISHER Supplying, Installation, 2724.25 No
Testing and commissioning of Dry Chemical
Powder (DCP) 6 Kg Fire Extinguisher Mono
Ammonium Phosphate Powder 40, Stored
Pressure Type, Pressure Gauge, Controllable
discharge mechanism Class A, Rating 3A & Class
B rating 21B as per IS 15683 ISI MARK (ABC Dry
Chemical Powder - MAP 40%)fitted with required
accessories including wall suspension brackets.
2.1.2 3 Supplying, fixing, testing and commissioning of 6526 No
CO2 type Fire Extinguisher of capacity 4.5 kg
filled with Co2 Gas as per IS 15222 with controll
discharge mechanismfitted with Hose & Horn
applicable on Class B fire rating 21B confirms to
IS 15683, bearing ISI mark. Co2 Cylinder as per
2.1.3 1 Providing & fixing of ISI marked water CO2 type 3450 No
Portable fire extingusher,9 LTR capacity,
Hydraulic test pressure 35Kgf/ cm2, Discharge
range 2 Mtr,Average discharge time: Min.
13Sec,Fire Rating 3A,Grade: IS:15683.
2.1.4 1 Providing & fixing of ISI marked, Squeeze Grip 4200 No
Cartridge Type water CO2 type Portable fire
extingusher,9 LTR capacity, Hydraulic test
pressure 35Kgf/ cm2, Discharge range
Mtr,Average discharge time: Min. 13Sec,Fire
Rating 3A,Grade: IS:15683.
2.1.5 1 Providing,fixing, testing and commissioning of 2950 No
10Kg Modular type fire extinguisher having
Nitrogen expellant ,ceiling mounted,Sprinkler
Nozzle is gas tight the release temperature is
adjusted with sprinkler imported bulb set at
57 degree C or 68 degree C ,coverage area 4 to
2.2 LIGHTNING ARRESTER
2.2.1 4 SITC of Vertical Air Termination Solid aluminium 9323 No
with Base- 10 mm dia and 1000 mm long. Air
Termination Base tested for conditioning, Ageing
Test & Lightning impulse current withstand test:
100 kA of 10/350µs waveform in an accredited
Third party laboratory as per 6.3 & 6.4 of IEC
62561-1 2017 protocol with MAST 34mm dia
mm long- Cold Galvanized
2.2.2 110 SITC of 8 mm dia solid Aluminium Conductor for 297 Mtr
roof top mesh grid and tested as per IEC 62561-
2 conducted in the Govt. accredited thirty party
laboratory to meet the requirement of IS/IEC
62305 with Required Accessories - Aluminium
Holding clamp at every 1 mtr distance,
Aluminium/SS cross splicer at every crossing of
Alu. conductor, Expansion piece with connectors
at every 20 mtr distance, Aluminium straight
Splicer to connect conductors. All Accessories
should be tested as per IEC 62561-1 2018 Cl.
for conditioning & Ageing Test & 6.4 for Lightning
impulse current withstand test: 100 kA of
10/350µs waveform(Ageing & Electrical test )
conducted in a sequence manner & tested in the
Govt. accredited Third party laboratory to meet
the requirements of IS/IEC
2.2.3 90 SITC of Galvanized Steel Flat 25x6 mm thickness 153 Mtr
from earth electrode directly in ground as
required. Zinc coating: 500 g/m square
(Approx:70 micron coating) tested and used
exclusively for lightning protection earthing system
and ring equipotential bonding.
2.2.4 4 per set No
SITC of 14.2 mm dia 3 mtr long Earth electrode of
High tensile steel electrode with 250 micron
copper bonding & 1 bag of Carbon fill Based
environment friendly backfill tested as per IEC
62561-7 in NABL accredited Laboratory and
suitable stainless Steel double sided clamp. Eco
Friendly rust proof heavy duty weather proof
Polyethylene Earth Pit Chamber with following
dimensions :254 mm dia (top), 330 mm dia
(bottom) & 260 mm (height).
SUB TOTAL of FIRE EXTINGUISER &
Lightning Arrester
3.0 FIRE DETCTION & FIRE ALARM SYSTEM
3.1 1 SITC of Microprocessor based Net-workable 118852.5 No
Analogue Addressable Fire Alarm Control
Panel. The Panel shall be compliant with EN54-2,
EN54-4 and approved by LPCB. The Fire Alarm
Control Panel shall have inbuilt one loop. The
Panel must have large graphic display. The Panel
must also have the capability to take Addressable
Intelligent Wired and Wireless Devices on same
loop. Each loop shall have a capacity of
analogue Addressable devices and 127 Base
sounders/Base Sounder Beacons. The Panel
shall have 240 V AC power supply along with
automatic Battery Charger. Non-Networkable
Approved by LPCB (Including Five year free
maintenance with guarantee)
3.2 55 SITC of Analogue Addressable Multi- Sensor 3597.2 No
which is fully compatible with Analogue
Addressable Protocol,having removable high
performance chamber with Twin fire LED's allow
360 degree viewing, User selectable sensitivity
modes 1% to 4.5% obs/m, Incorporate Optical
and dual Heat elements, lock mechanism (sensor
to base), Electronically addressed, Pulsing/non-
pulsing controlled from panel. Approved by LPCB
& VdS. (Including Five year free maintenance with
3.3 15 SITC of Analogue Addressable Multi- Heat 3498.3 No
Sensor which is fully compatible with Analogue
Addressable Protocol,having removable high
performance chamber with Twin fire LED's allow
360 degree viewing, User selectable sensitivity
modes 0 to 88 degree Celsius, Incorporates Fixed
Temperature and Rate Of Rise Heat elements,
lock mechanism (sensor to base), Electronically
addressed, Pulsing/non-pulsing controlled from
panel. Approved by LPCB (EN54: Part 5)
(Including Five year free maintenance with
3.4 70 SITC of sensor common mounting base, includes 354.2 No
stainless steel contacts, slim profile - only 8mm,
quick connection via square cable clamps, facility
for remote indicator, Approved by LPCB
(Including Five year free maintenance with
3.5 6 Supply,Instllation,Testing and Commissioning of 2477.1 No
Fault isolator Module capable of monitoring
shorted loop circuit and automatically restore
communications when shorted conditions are
corrected (Including Five year free maintenance
with guarantee)
3.6 8 Supplying, installation, testing & commissioning of 193.2 No
response indicator on surface/recessed MS Box
having two LED, metallic cover complete with all
connections etc as required.
3.7 6 SITC of Manual Call Point approved to EN54- 4191.75 No
11:2001, Approved by LPCB Easy to install, push-
fit wiring terminals (Including Five year free
maintenance with guarantee)
3.8 6 SITC of Analogue addressable loop powered 7442.8 No
Base Sounder, variable sound output 50 ~
dB(A) (±2 dB(A)) output at 1 metre, 51 user-
selectable tones (all tones EN54-3 compatible),
Auto shutdown feature prevents noise-pollution,
Approved by LPCB & VdS (Including Five year
free maintenance with guarantee)
3.9 750 Supplying & laying of 2x1.5 sqmm fire alarm 135.7 Mtr
armoured cable, 600/1000V rated with annealed
copper conductor having XLPE insulation, steel
wire armouring & FRLS outer sheath complete
SUB -TOTAL OF FIRE DETECTION&
4.0 Annual Comprehensive Type Maintenance
Contract of for Above Fire Fighting System
For 1-Year DLP + ONE Year
Every six months Testing certificates with
Photographs should be sent to competent
authority by concern contractor.
4.1 1 Annual comprehensive Type Maintenance 0 Year
Charges only During 1st Year DLP / Defect
Liability period.
Annual comprehensive Type Maintenance
Charges for 1st Year after Guarentee / Defect
Liability period.
SUB TOTAL of Annual Comprehensive
Maintenance of Fire Fighting Sytem
Furniture Work ( Curtains and Cupboard
Proviging and Fixing Storage Shutter
made out of 50mm X 25 mm Indian
Teakwood Frame and 18 mm Ply Board.
With 1 mm thick laminate finish in the
front and 0.8 mm thick Laminate on Back
Side with 12 mm thick Indian teakwood
beading. The scope also include
providing and fixing s.s. finish hardware
1 80 as per the Requirement. The rate include
cost of all labour, material and with all
hardware like handle, magnate, tackels,
adhesive, screws, etc.for satisfactory
completion of this items.All Exposed
Wood Work shall have malamine polish
Meeting Table Ovel M4 ( 1355 MM
Providing and supplying meeting table
ovel in shape of size 1355 mm Wide as
shown in drawing.The top made out of
19 mm thk.ply wood with laminate top
as shown in drawing.20 mm thick teak
wood beading is provided all around
table top with 5 mm groove in the center.
The top is supported by 2 nos. of vertical
2 6 square box made out of 19 mm thick ply
board of size 300mm x 300mm rest on
the wooden base of size 400mm x
400mm x 40mm as shown in
drawing.The rate includes cost of all
labour,material and with necessary
tools,tackles,adhesive,screws,etc.for
satisfactory completion of this item.
3 Providing & Fixing Sun Control
Reflective Type Film / Frosted Film as
Selected by Architect/ Engg. In Charge
For Glass Doors / Windows etc. as
100.00 Directed. 646.37 Sq.mt.
4 Providing & Fixing in Position Vertical
Roller Blinds with Minimum 3 % and
Maximum 5 % Light Transperace Screen
Fabric Incuding Providing & Fixing of
Powder coated G- Channel at the Topof
Window with necessary Screw , Cleats
etc. and PVC Roller ( Weight Pipe) and
PVC Chain For Up and Down Movement
of Blinds etc. of Approved Make and as
per Drawings / Instruction of Engg. in
Charge For All Colors and Shades.
Rates Includes all Lead and Lift For All
Floor Level, All Height , All Material
Accessories, Fixing , Scaffolding , Labor
etc. Complete in All Respects. All
Required Accessories & Material must
be From Same Manufacturer.
5 Cubical track for cubical curtain :- supply
and installation of heavy duty Aluminium
cubical track size 20mm wide x 30 mm
high, made of aluminium Extruded with
white powder coating complete with
continous PVC liner, nylon giders and
hooks , plastic end cap, connecting
bridge, overlapping joint connector, Wall
bracket with matching screws to make
up cubicle approx. height to 2100 mm
clearance from floor level at approx.
1000 mm spacing with all accessories of
approved brand/make along with
alluminium Extruded hospital curtain's
track system with shite powder coating
with all accessories as per approved
sample. All required accessories and
materials must be from same
manufacturer. This Item is Excluding
6 Cubicle Curtain :- Supply & Installation of
Water Repellant, Antimicrobial Cubicle
Curtain with High Strength18" Oval net at
Top as Approved by Consultant / Engg.
In Charge. Eyelets on Curtains & Hooks
and All other Required Accessories,
Fixing , Scaffolding, Labor etc. Complete
in All Respects. All Required
Accessories & Material must be From
Same Manufacturer.
Total of Furniture Work ( Curtains and
Cupboard Shutter)
Signature of contractor Additional City Engineer ( EAST ZONE)
Seal Ahmedabad Municipal Corporation
AHMEDABAD MUNICIPAL CORPORATION
ENGINEERING DEPARTMENT- EAST ZONE
NAME OF WORK:- CONSTRUCTION OF U.H.C. BUILDING AT F.P. NO :- 33 , DRAFT
T.P.S. NO: 64 (GHODASAR-2) IN RAMOL WARD , EAST ZONE, AHMEDABAD.
FINANCIAL BID ( To Be Submitted Online Only )
Sr. No. Description Amount
1 Amount For Civil Work Rs.
Amount For Electrical Work with Annual Operation & Comprehensive
2 Maintenance for 1 Years after completion of DLP of 1 Year Rs.
Amount For Fire Fighting System Work with Annual Comprehensive
3 Maintenance for 1 Years after completion of DLP of 1 Year Rs.
4 Amount for Furniture Work ( Curtains and Cupboard Shutter) Rs.
I/We am/are willing to carry out work at ______ % Above / Below (should be written in figures
and words) The Estimated Cost Mentioned Above.
Estimated cost put to tender: Rs.3,91,53,416.09 Estimated cost put to tender: Rs.
Add_____% above : Rs ___________ Deduct_____% below : Rs __________
In words : Rupees _______________________ In words : Rupees_____________________
Signature of contractor Additional City Engineer (EAST ZONE)
Seal Ahmedabad Municipal Corporation
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
RAMOL UHC EZ Vol-1 part A Tender Document.pdf
RAMOL UHC EZ Final Price Bid Vol.-II.pdf
RAMOL UHC EZ Vol-1 Part B TS Civil Work.pdf
RAMOL UHC EZ Vol-1 part-C Electrical Specification.pdf
RAMOL UHC EZ Vol-1 part-D Fire Fighting Specification.pdf
RAMOL UHC TENDER DRAWING.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .