Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC NABAJIBAN 1 NABAJIBAN COLONY BISHARPARA KOLKATA 700158 WEST BENGAL | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700158 | ₹4.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹5.1 LRejected-Finance 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | ₹5.1 L | L2 | Rejected-Finance L2 |
| 3 | L3₹5.3 LRejected-Finance 33 PEMANTLE STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | ₹5.3 L | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹11,180
Closing Date
2 Jan 2026, 12:00 pmClosed
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
Annual Maintenance of Electrical Installation of the Entire System at Maulana Abul Kalam Azad Bhawan, Salt Lake ------- Urgent re-installation of 11 TR ductable Ac machine and allied works
2025_WBPWD_966052_1
WBPWD/EE/BED/e-NIQ-106/2025-26
Open Tender
ELECTRICAL WORKS M/R
14 days
Maulana Abul Kalam Azad Bhawan
Please refer Tender documents.
5 documents required · 5 mandatory
₹11,180
Room No. 108, Purta Bhawan, Salt Lake
14 Jan 2026
3 Dec 2025
5 Jan 2026
10 Dec 2025
2 Jan 2026
18 Dec 2025
15 Dec 2025
Amount
Takendown the 11 TR outdoor unit ductable type A.C machine(make - Voltas),disconnecting refrigerant hard round copper pipe,1-1/8 suction line & 5/8 liquid line by gas welding & dismentaling electrical gadgets,contractor,condenssor blower motor etc.
providing and constructing 03 (three) numbers of RCC pillar supports for each machine. Each pillar will have a height of 3 feet from the existing ground level and a base dimension of 1 ft × 3 ft.The RCC (Reinforced Cement Concrete) pillars will be constructed using cement, sand, stone aggregates, water, and suitable steel reinforcement bars (rebar). The process includes excavation as required, formwork, reinforcement placement, proper concreting, curing, and finishing to ensure adequate strength, stability, and durability of the support pillars.
Disconnect electrical connections, refrigerant lines, drain lines, communication cables, and supports &r ecover refrigerant gas from the system using proper tools as per safety standards and reinstallation of the existing 11 TR outdoor machine in new Pillar Support
S/F 4 pole Contactor 32 MCX03 -CS97011 MCB(L&T, ABB,Schneider Electric)
Repairing of 2 ft × 2 ft (four-side) duct insulation for a total length of 20 ft to prevent sweating Checking the full length of the duct (20 ft) for damaged, loose, soaked, or missing insulation.Cleaning the duct surface by removing old or wet insulation material ,as well Checking for air leakage observing for condensation formation after system restart
Repairing of 1/2 HP Condenser Blower Motor (Make: Marathon) including Checking the blower motor for faults such as bearing damage, coil burn, capacitor failure, loose wiring, or abnormal noise/vibration.Testing insulation resistance and continuity alo replacing capacitor, bush, fan blade key, or terminal connectors if required as wel Tightening all nuts, bolts and aligning the shaft properly.Checking RPM, noise level, vibration, and temperature rise
Repairing of broken angle supports of the blower motor inside the outdoor machine by electrical welding, including repairing of broken angel supports of the blower motor inside the outdoor machine by electrical welding.
Charges for providing 22 SWG GI sheet outdoor fan ducting of 700 mm diameter and 300 mm length, including materials, complete in all respects providing necessary flanges, supports, rivets/screws, sealant, and fixing accessories
Supply and Fixing (S/F) of 11 TR M-Controller for controlling the AHU unit and the corresponding outdoor unit
Supplying and laying of 1-1/8" and 5/8" hard-drawn copper pipes with nitrile rubber insulation.
Replacement of the existing 11 TR AHU expansion valve with a new expansion valve (Make: Danfoss)Installing the valve with proper alignment, flare/brazed joints, and required accessories. Ensuring nitrogen purging during brazing to avoid carbon formation inside the copper lines
Replacement of Air Handling Unit (AHU) Filter of size 610 × 610 mm , Filtration Medium Material Synthetic Fiber, Construction Panel Filter, Material Aluminum, Medium Material Synthetic -Fiber Filtration Grade- Pre Filter
Supplying and fixing long filter drier (Size: 5/8" × 5/8") for removal of moisture from the refrigeration system and protection of the expansion valve from choking
S/F of 4 core 6 mm un. armor flexible copper cable.
S/F 3 core 2.5 sqr/mm copper main cord for inter connection in indoor & outdoor unit.
Supply & laying 1.1 KV Power Cable 4 core 16 sqmm stranded AL armoured cable. (Glostar/KEI/RR Kabel)
Charges for refrigeration Gas - R-22.
Carrying charges for Company’s Nitrogen cylinder, vacuum pump motor, and gas cylinder set from the workshop to the work site and back, including complete leak testing of the entire refrigeration system by an expert technician using high-pressure nitrogen, flushing of the condenser unit and refrigerant pipelines with nitrogen pressure, and thorough vacuuming of the system to remove moisture, air, and non-condensable gases, ensuring the system is fully clean and ready for refrigerant charging.
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
CARRION AIR COOLING (BID ID -7753225)
MILLENNIUM AIRCON (BID ID -7767880)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid