Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.9 LAccepted-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹45.9 L+₹2.0 L (4.58%)Rejected-Finance HQ CE SC PUNE | PUNE | MAHARASHTRA | 410301 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹46.6 L+₹2.7 L (6.06%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹46.8 L+₹2.8 L (6.47%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹47.1 L+₹3.2 L (7.30%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L5 | Rejected-Finance Being L5 |
Tender Value
₹35.5 L
EMD Value
₹71,000
Closing Date
9 Dec 2023, 6:00 pmClosed
Lt Col Utkarsh Sharma GE
Opposite Birla factory GE I CG PORBANDAR
PROVISION OF DG SET FOR CERTAIN WATER SUPPLY INSTALLATIONS, FIRE FIGHTING PUMP HOUSE, SECURITY LIGHTS, PROVISION OF COOLING APPLIANCE AGAINST BER AND CERTAIN MINOR WORKS AT PORBANDAR UNDER GE (I) CG PORBANDAR
2023_MES_625515_1
8929/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
PORBANDAR
As per NIT
8 documents required · 8 mandatory
₹500
GE I CG PORBANDAR
₹71,000
Yes
22 Dec 2023
28 Oct 2023
11 Dec 2023
28 Oct 2023
9 Dec 2023
4 Dec 2023
Amount
SCHEDULE 'A' B/R ITEMS
Excavating in post holes (or similar holes) each not exceeding 0.5 Cum, getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exceeding 50 Metre and making good surface, complete all as specified & directed by Engineer-in-Charge.
Material & labour for Cement concrete in foundations, filling and mass concrete in PCC 1:2:4 Type B-2 (using 40mm graded stone aggregate), complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing Rolled sections of Fe 410-W (GdeE- 250) quality-A as in main and cross beams, column, hip and jack rafters; purlins, where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of approved colour and design having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified & directed by Engineer-in-Charge.
Material & Labour for preparation of new steel & iron surfaces & applying two coats of synthetic enamel paint over 10 cm width or girth etc., complete all as specified & directed by Engineer-in-Charge.
Material & Labour for Cement concrete 1:3:6, type C-1 using 20mm graded stone aggregate in plinth protection, 50mm thick, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight, complete all as specified & directed by Engineer-in-Charge.
SCHEDULE 'A' E/M ITEMS
Supply, Installation, testing and commissioning of factory assembled silent diesel engine driven generating set, conforming to IS 10002: 1981and latest CPCB-II Norms, capable of giving continuous output of 62.5 kVA at 0.8 (lagging) power factor and 50 Hz frequency, suitable for 3- Phase, 4 Wire AC system complete with diesel engine of suitable BHP and AC brushless SPDP alternator, conforming to IS 13364: 1992, mounted on a common base frame and coupled through a flexible coupling or close coupled complete with platform, anti-vibration pad, control panel having meters, sound-proof canopy, etc. complete all as specified and directed by the engineer-in-charge. Make: Kirloskar, Crompton Groves, Cummins The DG Set shall conform to the following specification / criteria: [a] Diesel Engine: 4 cylinder, in-line, 4 stroke, radiator cooled engine, conforming to ISO 8528 - 1: 2005, IEC 60034 -1:2017, BS 5514 -1:1996 and ISO-1:1996, well designed air handling system with dry pipe, heavy duty, replacable paper element air cleaner with restriction indicator, air to air after cooling, optimised turbo charger for increased altitude, in-line fuel pump with class H electronic governing, spin on fuel filter, standard integral set-mounted radiator system, designed and tested for 50 °C ambient temperature, full flow spin on lube oil filter, electrical starter motor with soft start engagement feature, battery charging alternator with 1 X 24 V or 2 X 12 V DC dry type battery and consisting of the following accessories:
(i) Radiator having blower fan & guard, (ii) Pipe coupling for cooling system, (iii) Corrosion inhibitor coolent. (iv) Filters at fuel/ lube oil (v) Fly wheel housing and fly wheel suitable for alternator, (vi) Shut-off coil protection with safety for LLOP/HWT/ overspeed/ high & low DC voltage, (vii) Dry type heavy duty replaceable paper element air cleaner with restriction indicator and vacuum indicators, (viii) Residential silencers, (ix) Stainless steel exhaust flexible bellows, (x) Motor driven priming pump. (xi) Electric starter motor, (xii) Battery charging alternator, (xiii) Exhaust piping made out of Class 'C' MS pipe inclusive of all accessories and mineral wool Insulation covered with aluminum sheets for the entire length of exhaust pipe as per manufacturer's recommendation, (ixv) First fill of oil, coolant and diesel during commissioning (xv) Interconnecting copper cabling of adequate capacity between batteries and controller, (xvi) MS Class C fuel pipe, (xvii) Self starter 12/24 V DC, (xviii) Metering equipment for recording (a) Battery voltage and charging rate, (b) Coolant temperature, (c) Lubricating oil pressure, (d) Engine speed (RPM), (e) Engine hours run, (f) Balance of fuel,
(ixx) Safety & Protection (Trip & Indication) (a) High water temperature, (b) Low lube oil pressure, (c)Low and high speed trip, (d) High and low DC voltage, (e) Overspeed stop. (xx) Base frame having sturdy fabricated welded construction, channel iron (duly painted), (xiii) 12 V, 180 Ah maintenance free batteries with leads and terminals, (xii) Built-in fuel tank having diesel storage capacity not less than 12 hrs running of DG set or as per manufacturer's recommendations complete with drain plug, vent, inlet and outlet connections, level indicator and position for cleaning, [b] Alternator:- 62.5 kVA at 1500 RPM, 0.8 (lagging) power factor and 50 Hz frequency, suitable for 3-Phase, 4 Wire AC system and self regulated with AVR brushless excitation band of voltage ± 1% of rated voltage from no load to full load, insulation class 'H', self ventilated, IP23 protected with telephonic harmonic factor < 2%, maximum unbalanced load across phases less than or equal to 25% and conforming to IEC 60034 -1:2017 and ISO 8528 -1: 2005, suitable for the diesel engine specified above.
Supply and laying of XLPE insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 50 Sqmm 3.5 Core laid in trenches/along the wall/pole including making all connections, complete all as specified & directed by Engineer-in-Charge. Make : Polycab/Havells/RR Kabel/Plaza
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out Soft/ Loose soil, complete all as specified & directed by Engineer-in-Charge.
Returning filling in including spreading levelling watering and well Ramming in layers not exceeding 25 cm thick, complete all as specified & directed by Engineer-in-Charge.
Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing of GI steel tubing light grade 80mm dia for laying in ground and road crossing along the pole in coping etc. for cable protection including necessary fittings, clamps for supports, etc., complete all as specified & directed by Engineer-in-Charge. Make - Tata/Jindal/Surya Prakash
Material & Labour for cutting existing road/hard standing not exceeding 45cm x 45cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil, complete all as specified & directed by Engineer-in-Charge.
Supply and laying 77/63 mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables, laid in trenches/ road/ drain or fixed along wall, poles or laid under floor, complete all as specified & directed by Engineer-in-Charge. Make: Rex/Poly/Gemini
Material & Labour for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, 4 wire +E, fabricated Polycarbonate, RAL 7035 finish confirming to IP 54 complete including Copper bus bar 200 Amps, 36 KA, 4 strip mounted on porcelain insulated & enclosed in chamber, bottom cable entry comprising of following :- (a) Incoming MCCB 100 Amps four pole with Thermal based operated, having breaking capacity 25 KA, - 01 Nos (b) Outgoing MCCB 63 Amps four pole with Thermal based operated, having breaking capacity 16 KA, - 01 Nos. (c) Outgoing MCCB 40 Amps four pole with Thermal based operated, having breaking capacity 16 KA, - 02 Nos., (d) Digital Voltmeter 0-500 V 96x96m - 01 Nos, (e) Digital Ammeter 0-500 A 96x96m - 01 nos., (f) Indicating Lamps set RYB - 01 set Make : LT Panel polycarbondate : Hensel/Universal/Neptune. Note - The layout drawing of the panel shall be got approved by the contractor before panel fabrication.
Material & Labour for bore Earthing, 50mm bore for earthing with maintenance free GI bounded chemical earthing using GI electrode of size 50 mm dia - 01 No, 3 m long, GI earth strip, excavation and earth work, back fill with compound (Chemical for earth enhancer gel 2 x 25Kg) - 01 set. all as directed, shall be deemed to be included in the unit rate. Note: (i) IR Value should be less than 1.0 ohm. (ii) Aluminum earth stip of size 25 x 3 mm including installation 7.5 m (Copper purity not less than 99%) is deemed to be included in the unit rate. (iii) Suitable FRP Chamber should be included in the unit rate.
Supply and fixing refrigerator, electric driven (single phase), of 185Ltr capacity with inbuilt smart inverter compressor, with base stand drawer, single door, direct cool BEE 5 star rated, complete all as specified & directed by Engineer-in-Charge. Make:- LG / Godrej / Samsung / Voltas
Supply and fixing refrigerator, electric driven (single phase), of 308Ltr capacity with inbuilt smart inverter compressor, frost free, single door, direct cool BEE 2 star rated, complete all as specified & directed by Engineer-in-Charge. Make:- Godrej / LG/Samsung/Voltas
Supply and fixing refrigerator, electric driven (single phase), of 330Ltr capacity with inbuilt smart inverter compressor, frost free, single door, direct cool BEE 2 star rated, complete all as specified & directed by Engineer-in-Charge. Make:- Godrej / LG/Samsung/Voltas
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having 80Ltr storage and 40Ltr nominal cooling capacity, complete all as specified & directed by Engineer-in-Charge.
Supply, fixing and install hi wall split units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum BEE 5 star rating of capacity 1.5 Ton Inverter type, electric driven, single phase, 230 Volt, Heavy duty outdoor unit mounting bracket/stand, complete all as specified & directed by Engineer-in-Charge. Make : Voltas /Carrier/Blue Star
Supply and fixing Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short, complete all as specified & directed by Engineer-in-Charge.
Supply and fixing Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard, complete all as specified & directed by Engineer-in-Charge.
Supply and fixing hose reel of 63mm dia and 15 metre long conforming to IS 636, complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing for motor strater 2 module, Modular MCB 16 Amps 1 module including suitable for PVC Box 3 Module with Cover plate, complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing for Modular Socket 6A/16A - 2/3 pin 3 Module type, 240 volts, including suitable for PVC Box 3 Module with Cover plate, complete all as specified & directed by Engineer-in-Charge.
Supply & Fixing Rigid non-metallic PVC conduit of size 20/25 mm dia, exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. including fixing arrangements/mounting brackets, complete all as specified & directed by Engineer-in-Charge. Make: Supreme/Astral/ Plaza/Anchor Note: Drawn through wall surfaces for waste water pipe, and including making good the disturbed surfaces of walls/ceiling/floor etc.,
Material & labour for Sub main wiring with two runs of 4.00 Sqmm single core PVC insulated but unsheathed multstranded copper conductor FRLS 1100 Volts grade cable, drawn through and including PVC casing capping, wall suface, making good the disturbed surfaces of walls/ceiling/floor etc., including accessories and one run of 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth conductor, complete all as specified & directed by Engineer-in-Charge. Note: All runs of cable and 1 run of conduit/casing capping shall be measured and paid as one metre length of unit.
Material and labour for Hot dip galvanized supports for canopy (BBT/Cables /pipes) etc, as per site condition such as 'C' brackets, Angles, threaded rod etc., including making all connections complete as required at site, complete all as specified & directed by Engineer-in-Charge.
Material and labour for Hot dip galvanized 3mm thick Plain sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) etc., including making all connections complete as required at site, complete all as specified & directed by Engineer-in-Charge.
Supply & Installation of Advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (Zinc & Alloy Coated), ZINC COATED (80-100) microns with pure Zinc(99.9%) & ALLOY COATING (200-250)microns. Earthing System confirming IS 3043. The outer and inner pipe should be 89mm(wall thickness of 3.2mm) & 42mm (wall thickness of 3.2mm) dia, 3 Metre Length, Zinc coated with additional special Alloy coating 300mm on the top side for additional protection of the Terminal. A ground breaking corrosion resistant Crystalline Conductive Compound (CCC) is filled and compacted in the cavity within the pipes to enhance the electrodes performance. i.e. the pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity, The job includes digging the pits and refilling the same by BARON ELECTRODITE Back Fill compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having ROHS, Certification from NABL accredited lab. The earth pit should be provided with a FRP or Polyplast earth pit cover for protection and safe guard of terminals. In areas where soil condition is bad, GOOD EARTH i.e. BLACK COTTON OR MOISTURES NORMAL SOIL is to be arranged to fill the excavated pits by mixing the arranged soil with BFC 3 bags ELECTRODITE (25kgs/bag) & TERRION(10kgs/bag) for installation of earth electrode. The material should have good electrical conductivity & anti corrosion property in wide range of soil conditions. The buried Conductor Copper is to be covered by 50mm thick layer of ELECTRODITE for additional protection of conductors & better conductivity to lower the resistivity of soil & bring down earth resistance. Make Ashlok- Model :ASEEL 453 Z 100 PIP (Zinc & Alloy Coating) or " ENNOB" "INDELEC", "ERICO", "MACMAE", "MARCONITE". Note:- Installation of Earth Pit:- Digging & excavation of earth pit of 8-10 inch dia 11 feet depth. The earth electrode of 89mm dia to be inserted in the pit & rest area of the pit to be filled & packed with ELECTRODITE bfc & same to be rammed to clear air gape. Additionally around a driven earth electrode a circular trench is to dug 1 feet away from earth electrode about 1 feet dia & 6 inch-1 feet depth. TERRION bfc is to be filled & packed in the dug trench by pouring some water & cover the same with soil & finally the terminal to be connected with conductors & FRP/POLYPLAST earth pit cover to be fixed for safe guard of earth pit.
K B N TRADERS
RUDRAAY CONSTRUCTION
ALBA AC AND REF SERVICES
SURESH ELECTRICALS
roxy enterprise
JAY BHARAT METAL SUPPLIERS
Vijay Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .