| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 CrAccepted-AOC | ₹31.6 Cr | L1 | Accepted-AOC Accepted being workable and reasonable rates are quoted |
| 2 | L2₹32.9 CrRejected-Finance | ₹32.9 Cr | L2 | Rejected-Finance Being L2 |
| 3 | L3₹33.6 CrRejected-Finance | ₹33.6 Cr | L3 | Rejected-Finance Being L3 |
| 4 | L4₹33.7 CrRejected-Finance | ₹33.7 Cr | L4 | Rejected-Finance Being L4 |
| 5 | L5₹33.9 CrRejected-Finance | ₹33.9 Cr | L5 | Rejected-Finance Being L5 |
Tender Value
₹34.7 Cr
EMD Value
₹15 L
Closing Date
6 Jun 2023, 6:00 pmClosed
DDG and CE
DGNP V Near Pipeline Junction Naval Base Post Visakhapatnam
SETTING UP OF CENTRE FOR INTERMEDIATE LEVEL MAINTENANCE CILM OF LM 2500 GAS TURBINES
2023_MES_581570_2
DDG CE V TOKEN 07 OF 2022-2023
Open Tender
Civil Works
730 days
VISAKHAPATNAM
As per NIT
7 documents required · 7 mandatory
₹3,000
DGNP
₹15 L
Yes
27 Oct 2023
25 May 2023
8 Jun 2023
25 May 2023
6 Jun 2023
1 Jun 2023
25 May 2023 - 29 May 2023
Amount
SCHEDULE "A" PART - I [CIVIL WORKS]
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by the Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed by the Engineer-in-Charge.
Removing the demolished building materials / debris, etc. (other than spoil) to a distance exceeding 100m and upto 5Km, including loading, unloading and depositing at designated places, complete all as specified and as directed by the Engineer-in-Charge. Note: 1. Materials considered under Schedule of Credit shall not be considered under this item. 2. Definition of load shall be as given in Section 21 of SSR Part II.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft / loose soil including removing / grubbing of roots of shrubs or trees not exceeding 30 cm girth and disposal of the same to a distance exceeding 5 km and not exceeding 10 km outside the MoD land, complete all as specified and as directed by the Engineer-in-Charge.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in hard / dense soil, complete all as specified and as directed by the Engineer-in-Charge.
Excavating over areas, not exceeding 1.5 m in depth and getting out in hard / dense soil, complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No.1.006 above, but depth exceeding 1.5 m but not exceeding 3 m.
Excavating over areas, not exceeding 1.5 m in depth and getting out in soft / loose soil, complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, pile cap, beams, shafts, wells, manholes, pier holes, laying of under ground cables or pipe etc., not exceeding 10 sq m on plan and getting out in hard / dense soil, complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 1.009 above, but depth exceeding 1.5 m but not exceeding 3 m.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, pile cap, beams, shafts, wells, manholes, pier holes, laying of under ground cables or pipe etc., not exceeding 10 sq m on plan and getting out in soft / loose soil, complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 1.011 above, but depth exceeding 1.5 m but not exceeding 3 m.
Returning, filling in including, spreading, leveling, watering and well ramming in layers not exceeding 25cm thick as in any type of soil, complete all as specified and as directed by the Engineer-in-Charge. Notes: (i) 10 % Deduction shall be made from total computed volume of filling to cater in bulk in respect of mechinery used for ramming (ii) Compacted thickness wiil be measured for the payment purpose.
Material and labour for Sand filling under floors or in foundations including watering and consolidation, complete all as specified and as directed by the Engineer-in-Charge.
Removing the excavated material (soil) to a distance exceeding 1.5 km but not exceeding 5 km and depositing where directed at a level not exceeding 1.5m above the starting point at a designated place, complete all as specified and as directed by the Engineer-in-Charge.
Removing the excavated material (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point at a designated place, complete all as specified and as directed by the Engineer-in-Charge.
Removing the excavated material (soil) to a distance exceeding 250m but not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point at a designated place, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Hard core of gauge not exceeding 63 mm, broken stone or boulders deposited, spread, levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured), complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for fillings using approved moorum obtained from out side MD land of any lead including raising (or lowering) earth, spreading in layers not exceeding 30 cm thick, watering, rolling with power rollers to obtain standard proctor density not less than 95 percent under optimum moisture conditions and consolidations and finishing to required size, shape, camber, etc not exceeding 1.5 m height from base of moorum filling, complete all as specified and as directed by the Engineer-in-Charge. Note: Measurements of the finished surface of moorum/red bajri filling shall be taken after consolidation and 5% deduction shall be made for increase in bulkage.
Material and labour for PCC 1:2:4 type B-0, by using 12.5mm graded granite stone aggregate, as in foundations, filling and mass concrete, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for PCC 1:3:6 type C-2, by using 40mm graded granite stone aggregate, as in foundations, filling and mass concrete, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for PCC 1:4:8 type D-2, by using 40mm graded granite stone aggregate, as in foundations, filling and mass concrete, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for 75 mm thick PCC 1:3:6 type C-1 ( using 20mm graded granite stone aggregate), as in plinth protection , finished even and fair without using extra cement including making construction joints in 3 m interval and joint filled with sealing compound, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for providing precast Reinforced Cement Concrete 1:2:4, type B1 using 20mm graded stone aggregate as in cover slab for manholes / drains, chajjas, shelves, baffle wall and similar articles set in cement mortar 1:4 including necessary moulds finished plain fair surfaces, complete all as specified and as directed by the Engineer-in-Charge. Note: Reinforcement shall be measured and paid separately under relevant item of Schedule 'A'.
Material and Labour for providing PCC 1:2:4 , type B0 using 12.5mm graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles and throating, finished even and smooth, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for providing PCC 1:3:6 , type C1 using 20mm graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles and throating, finished even and smooth, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for precast cement concrete block masonry with solid blocks, exceeding 10cm in width as in curtain walls, made out of cement concrete 1:3:6 type C1 using 20mm graded stone aggregate and setting in cement mortar 1:6, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Reinforced Ready Mixed Cement Concrete (Design Mix) of grade M-35, as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns,etc., basement slabs, under reamed piles and mass concrete and including handling, conveyance, erection with alignment in true position, finishing, complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 1.032 above but in beams, cantilevers, lintels, columns pillars, piers, posts, struts, chullah hoods, stair case, arches, domes, vaults, shell roofs, arch ribs, folded plates, slabs, balconies, canopies, deck slabs etc. or in similar articles upto 5th floor level
All as per Item No. 1.032 above but in retaining walls, basement walls, ballast walls and the like, any thickness above top of footing including attached pilasters and buttreses.
All as per Item No. 1.032 above but in water tank walls, basements and the like, including mixing with crystalline admixture at 0.8% by weight of cement. Note: The rate quoted shall be deemed to include the admixture.
Supply only of Integral waterproofing compound, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for brickwork with fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 including supply and fix 2 no.s of 8 mm dia bars at every fourth course of brickwork, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Damp proof course in cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) of 40mm thickness to horizontal or vertical surface including necessary formwork, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and binding with clean dry sand @ 0.05 cum. per sqm, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sqm, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Stone kerb of granite or trap of roughly squared stones of size 20cm x 30cm, dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of surfaces jointed in cement mortar1:6 and struckflush, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 18 to 20 mm thick Granite stone slab (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platorms and like in cement mortar (1:4) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 18 to 20mm thick Granite stone slab (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Steel formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams,pile caps and similar work; vertical or to batter for flat rough finished surface of concrete, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Steel formwork to faces of walls , retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttressess, etc; vertical or to batter for flat fair finished surface of concrete, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping) for flat rough surfaces of concrete, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Steel formwork to chullah hoods, chajjas, troughs and similar items including edges, RCC gutters, cat walk and similar items with fair finished surface of concrete, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Steel formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams, etc with rough finished surface of concrete, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Steel formwork to staircases with sloping or stepped soffits including risers and stringers (excluding landing) with fair finished surface of concrete, complete all as specified and as directed by the Engineer-in-Charge
Material and labour for Steel formwork to sides of pillars, posts, struts, piers, columns and stanchions having square, rectangular or polygonal shape with fair finished surface of concrete, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix factory made Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, in 2nd class hardwood, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix factory made 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix factory made 30mm thick single piece, coloured ABC (ACRYLONITRILE BRUTADINE STYRENE) coated, PUF filled door shutters with PUF (PolyUrethane Foam) insulation of minimum density 40 Kg/Cum filled in between two ABS sheets of thickness 1.2mm (min), border covered with insitu pasted ABS strips of width equal to thickness of door shutters, 1.2mm thickness, reinforced with two number 10mm CTD bars, pre-embedded with wooden blocks of suitable sizes for receiving hinges, tower / sliding bolts, towel rails, handles etc, with/without embossed pattern, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix factory made Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and all as specified and as directed by the Engineer-in-Charge.
Supply and Fix 200 mm long aluminium anodised, barrel tower bolts with plates, staples, of extruded section, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix 150 mm long aluminium anodised, barrel tower bolts with plates, staples, of extruded section, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix 100 mm long aluminium anodised, barrel tower bolts with plates, staples, of extruded section, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix aluminium alloy, anodised, sliding door bolt of 300 mm length,with hasp, staple (bolt type), and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix aluminium alloy, anodised, sliding door bolt of 250 mm length,with hasp, staple (bolt type), and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix , 100mm size butt hinges, heavy weight made of cold rolled mild steel, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix , 75mm size butt hinges, medium weight made of cold rolled mild steel, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix , 100mm size butt hinges, medium weight made of cold rolled mild steel, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix 100mm size extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix 125mm size extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix mortice lock, vertical type, brass, of size 100mm with 4 levers, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix hat pegs, solid body, 125mm to 175 mm in set of three pegs, aluminium, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix floor door stopper of aluminium alloy body, and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix MS framed work such as grills, gratings, etc., with end of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290 Gde E-165, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix decorative type mild steel frame work as in gates with decorative grills of angle or other section with gusset plate, rail braces, etc complete including fixing of steel sheeting or other covering and hanging moved on sliding rollers on rails, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for 5 to 10 mm neck dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 10 cm but not exceeding 15cm long , complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for 16 to 20 mm neck dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 10 cm but not exceeding 15cm long , complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for reinforcement in any situation using corrosion resistant TMT steel bars of grade FE-500D, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 1.078 above but 6mm to 8mm dia.
All as per Item No. 1.078 above but, 5 mm dia and over upto and including 10 mm dia, in stirrups, spacers and binders, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fixing of Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, conforming to Fe-410W (Gde E250) quality 'A', complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fixing of Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, gusset plates, etc. conforming to Fe-410W (Gde E250) quality 'A', complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Rung Ladder, stairs (framed ) including stringers, treads, landing, balusters, hand rails, etc, including cleats brackets etc. conforming to Fe-410W (Gde E250) quality 'A', complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Steel Rolling Shutters without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated: Gear operated type with chain wheel and hand chain and lath thickness of 1.25mm, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Ball bearing for rolling shutters, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix powder coated aluminium frame for doors, windows, ventilators and shutters for doors and windows with extruded build up standard tubular and other section of approved make transparent or to required shade according to IS:1868 fixed with rawl plug and aluminium anodised screws or fixing with clips or with expansion hold fasteners including necessary filling up of gaps of junctions at top, bottom and sides with required PVC / neoprene felt, etc. Aluminium sections shall be smooth, rust free, straight mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading, panelling, aluminium anodised screws, complete all as specified and as directed by the Engineer-in-Charge. Note: Minimum thickness of powder coating shall be 50 micron.
Supply and Fix powder coated anodised aluminium door shutters, aluminium section weighing not less than 0.55 kg/ RM including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc., complete all as specified and as directed by the Engineer-in-Charge. Note: Minimum thickness of powder coating shall be 50 micron.
Supply and Fix powder coated anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less than 0.55 kg/RM including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.), complete all as specified and as directed by the Engineer-in-Charge. Note: Minimum thickness of powder coating shall be 50 micron.
Supply and Fix powder coated aluminium decorative grill for doors, windows and ventilators with one or more rebates including joining cleats / beading 'U' and 'H' channel for fixing, etc, complete all as specified and as directed by the Engineer-in-Charge. Note: Minimum thickness of powder coating shall be 50 micron.
Supply and Fix GI frame work of size of grid 605 x 605mm for seamless ceiling comprising of GI preimeter channel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surroundings wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre with GI cleat and steel expansion fateners with and including ceiling section (not exc 1.2 m length) of 0.55mm thickness having kurled web of 50mm and flanges of 26mm each with lips of 10.5mm fixed to the intermidiate channel with connecting clips across the intermediate channel at 457mm centre to centre,, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for providing and fixing stainless steel (Grade 304) railing of hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and filing the same with necessary stainless steel nuts and bolts complete, inlcuding fixing the railling with necessary accessories & stainless steel dash fasterners, stainless steel bolts etc. of required size, on the top of floor or the side of waist slab with suitable arrangements, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix glazing with float glass panes of 8mm thickness, in aluminum door, window, ventilator shutters and partitions etc with EPDM rubber / neoprene gaskets etc, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick, approved colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for APP based polymeric membrane minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyster none wove fabric (weight not less than 150 gms /Sqm ) laid on Bituminous Primer for use in Waterproofing and damp proofing treatments @0.5Lit/Sqm by torch application and apply two coat of aluminium paint including ponding test on completion, complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 1.096 above but excluding aluminium paint.
Supply and Fix Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of a colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix anodised aluminium snap grid frame of size 605mm x 605mm for false ceiling and 12mm thick gypsum board of size 595mm x 595mm on aluminium snap grid including galvanised wire of required length, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix 12 mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finishing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish, complete all as specified and as directed by the Engineer-in-Charge. Note: Frame work for ceiling shall be measured and paid separately
Material and Labour for Stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner @ 5% by weight of cement and stuck flush, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Edge stones to flooring with stone setts of size 250 to 300mm long x 150 to 200mm wide, and 450mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner @ 5% by weight of cement and stuck flush, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Machine cut kota stone slab flooring 18 to 20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Kota stone slab 18 to 20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Granite (of any type) tiles 18 to 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone inlcluding grinding and polishing, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 18 to 20mm thick granite (of any type) tiles machine cut, in skirting/dado laid on 10mm thick cement plaster with cement mortar 1:4 and jointed with grey cement slurry,and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 40 mm thick Precast cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) slab flooring, bedded, and jointed in cement mortar 1:6 and pointed in cement mortar 1:3, finished even and smooth using extra cement, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 80 mm thick Machine pressed precast concrete interlocking paver block of any shape and size, duly embossing the make, conforming to IS 15658-2006 of M-40 Grade laid over the sand cushioning with grey cement and pigment, complete all as specified and directed by Engineer-In-Charge. Note : Sand cushioning shall be measured and paid for separately.
Material and Labour for 100 mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base, floor, path, pavings etc, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 40 mm thick PCC ( 1:2:4 ) type B1 using 20mm graded stone aggregate as in sub base, floor, path, pavings etc, finishing the surface even and smooth using extra cement, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 50 mm thick PCC ( 1:2:4 ) type B1 using 20mm graded stone aggregate as in sub base, floor, path, pavings etc, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 25 mm thick PCC ( 1:2:4 ) type B0 using 12.5mm graded stone aggregate as in sub base, floor, path, pavings etc, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 40 mm thick PCC ( 1:2:4 ) type B0 using 12.5mm graded stone aggregate as in sub base, floor, path, pavings etc, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for glazed ceramic coloured / printed tiles in vertical surface 300mm x 450mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Vitrified Ceramic tiles of light shade, double charged, 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for factory made Cement concrete tiles 20cm x 20cm x 20 to 22mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors with grey cement and no pigment, and cut and polished, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Rubber tiles, 5mm thick, with fabric backing or insert, plain coloured or marbled topping, matt or glossy, laid in floors with approved adhesive, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for rendering 5 mm thick on fair faces of concrete surfaces of ceiling, soffits and sides of floors/roof beams and chajjas etc in cement mortar 1:3, finishing the surface fair and even, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for rendering to fair faces of brick / concrete surfaces, 10 mm thick in cement mortar 1:4, surfaces finished fair and even, including plaster grooves of size 10 mm x 1 mm at junction of RCC work, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for rendering 15mm (5mm thick over 10mm thick backing coat) thick on external faces of brick work or concrete surface in cement mortar 1:4, finishing the surface even and smooth without using extra cement mixed with water proofing compound on external coat of plaster, complete all as specified and as directed by the Engineer-in-Charge. Note: WPC shall be measured and paid for separately.
Material and Labour for 10 mm plastering in cement mortar 1:4 as in backing coat for tiles, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 15 mm thick screed bed or bedding layers in cement mortar 1:6, for laying floor finishes, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 20 mm thick screed bed or bedding layers in cement mortar 1:4, for laying floor finishes, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for three coats of white washing on newly plastered wall surface including preparation of surfaces, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for three coats of white washing on newly plastered ceiling surface including preparation of surfaces, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification including preparation of surface of wall, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for preparation of newly plastered surfaces of walls and applying two coats of exterior emulsion with anti fungal properties over a coat of primer, complete all as specified and as directed by Engineer-In-Charge.
Material and Labour for Providing and applying Cement base putty of 2 mm thickness over plastered surface to prepare the surface even and smooth, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Sheet glass of 5.5 / 6 mm thickness, ordinary quality and glazing with oil putty in square exceeding 0.5 sq. m in each pane, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 4mm thick figured glass, pin head type and glazing with oil putty in squares not exceeding 0.5 sq. m in each pane, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 6mm thick figured glass, pin head type and glazing with oil putty in squares not exceeding 0.5 sq. m in each pane, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Solar control film 25 micron reflective type ( gareware sun control or equivalent) for windows, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including preparation of surface of wall, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel painting over a coat of red oxide primer, complete all as specified and as directed by Engineer-In-Charge.
Material and Labour for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel painting on wood or wood based surfaces over a coat of pink primer, complete all as specified and as directed by Engineer-In-Charge.
Material and Labour for Galvanised steel water tubing 15mm bore, medium grade conforming to IS:1239(Part -I), ISI marked, with all fittings (such as bends, tees, short pieces, connectors, elbows, reducers, union sockets,etc) and laid in trenches, complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 1.137 above, but 20 mm bore.
Supply and Fix three layered Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), 10000 Litres, hoisted and fixed in position all as specified in SSR Part I, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix three layered Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), 2500 Litres, hoisted and fixed in position all as specified in SSR Part I, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix three layered Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), 1000 Litres, hoisted and fixed in position all as specified in SSR Part I, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix bib taps, cast copper alloy, fancy type, quarter turn, chromium plated with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferrule for 15 mm bore dia of pipe, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix 15 mm dia Concussive push button taps of cast copper alloy, screwed for iron pipe and fixed, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix 15mm bore chromium plated pillar taps, fancy type, cast copper alloy with capstan heads, quarter turn, screwed down high pressure with or without lettered Hot or cold with long screwed shanks and fly nuts, screwed for iron pipe, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure, quarter turn, screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Swivel shower of PTMT any colour for fixing with 15mm pipe (Minimum weight 40gm), complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Liquid soap container of Stainless steel fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 105gms), complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Towel Ring of Stainless steel fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) , complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix PVC connection (high density) 15mm dia of length 450mm with PTMT nuts both ends with rubber washer, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix PVC (SWR) 150mm bore pipes single socketed, ISI marked, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix PVC (SWR) 110mm bore pipes single socketed, ISI marked, in any length with rubber ring joints, laid in trenches or in floors , complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix PVC (SWR) 75mm bore pipes single socketed, ISI marked, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix PVC (SWR) 110mm bore bends of any radius, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix PVC (SWR) 110mm bore bends of any radius, fitted with oval access doors, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix PVC (SWR) 75mm bore bends of any radius, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix PVC (SWR) 75mm bore bends of any radius, fitted with oval access doors, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix 110mm dia PVC (SWR) branch pieces, (single Y), equal or unequal, ordinary or inverted including jointing with solvent cement, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix 110mm dia PVC (SWR) branch pieces, (single Y), equal or unequal, ordinary or inverted with oval access door including jointing with solvent cement, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix 75mm dia PVC (SWR) branch pieces, (double Y), equal or unequal, ordinary or inverted including jointing with solvent cement, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix 75mm dia PVC (SWR) branch pieces, (double Y), equal or unequal, ordinary or inverted with oval access door including jointing with solvent cement, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix PVC (SWR) 110mm bore vent cowl including jointing with solvent cement, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix PVC (SWR) 75mm bore vent cowl including jointing with solvent cement, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix, PVC(SWR) floor/Nahani trap 75mm size plain with grating including jointing to waste pipe with solvent cement, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix, PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Concrete bed with PCC (1:3:6) type C1 (using 20 mm graded stone aggregates) to drain pipes for 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Reinforced concrete pipes, class NP2, 150 mm dia, laid and jointed complete with collars, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Vitreous china Wash down water closet pan EWC (Pedestal pattern), white with 'P' or 'S' trap étc, (excluding flushing cistern and flush pipe) including plastic water closet seat, closed pattern with flat bottom cover, white in colour, mild steel chromium plated or aluminised hinging device, fixing bolts, etc , complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Toilet paper holder, coloured, Stainless steel, box type, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Vitreous China Urinal, full stall type, white (excluding flushing cistern, flush pipe and waste pipe), complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Vitreous China wash basin, white, flat back, size 630mm x 450mm excluding taps, waste, chain and plug and porcelain stopper but including brackets , complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fix Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 200 mm thick (spread thickness) GSB of shingle or gravel, spread, rolled and consolidated to gradient and camber required by providing close graded material (Grading II) mixing in mechanical mix plant at OMC spreading in uniform layers with motor graded and compacted with vibrator power roller, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 150mm thick WMM of two layers of 7.5cm thick (compacted thickness) WMM, with coarse aggregates of grading 2 (63 to 40mm size) or of grading 3 (50 to 20mm size), spread, rolled and consolidated to gradient and camber required, complete all as specified and as directed by the Engineer-in-Charge.
Preparing WMM surfaces by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc (surface preparation) and Material and Labour for applying evenly a priming tack coat with bituminous primer (paving bitumen VG - 10 grade bitumen ) @ 10 kg per 10 Square Metre over wet mix macadam, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 75 mm thick premix bituminous macadam over WMM using paving bitumen (paving bitumen of VG-30) @ 4% by weight of total mix laid with mechanical paver and rolled as per IRC norms and compacted to required gradient and camber, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for applying evenly a priming / tack coat with bituminous primer (paving bitumen VG-10 grade ) @ 5 kg per 10 Square Metre over premixed bituminous macadam, including preparing the surface of premix macadam, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Bituminous premixed semi dense asphaltic concrete 40mm thick (consolidated thickness) with 5.5% binder content (using paving bitumen of VG - 30 grade) by weight of total mix rolled with 8 to 10 tonne power roller and compacted to required camber and gradient using mechanical paver and Hot Mix plant, complete all as specified and as directed by the Engineer-in-Charge. Notes for Item No.s 1.176 and 1.178: (i) The binder content specified is for quoting the tender only. (ii) The mix design shall be carried out through a government lab. In case design of bitumen content is more than specified, no additional payment shall be admissible. However, if bitumen content is less than specified, the same shall be adjusted at supply only bitumen rate @ Rs. 46.50/kg.
Rolling and consolidating the formation surface (in cutting) with power roller 8 to 12 tonne, complete all as specified and as directed by the Engineer-in-charge.
Material and labour for underdeck insulation for metal roof with bonded fibre glass wool of density 24 Kg/Cum, 50 mm thick, suitably factory laminated with aluminium foil backed up by scrim and kraft paper (FSK), facing with 50 mm projection for overlap and butting comprising of the following: (insulating material shall conform to BS - 476, Part 4,5, 6 & 7), complete all as specified and as directed by the Engineer-in-Charge. :- (a) Supply and fix 6 mm dia M S rods between purlins suitably for supporting the required thickness of insulation material beneath the metal roof. (b) Supply and fix 22 SWG GI wires supports for insulation. (c) Supply and fix chicken wire mesh 12.5 mm x 22 SWG of hexagonal construction below the insulation for supporting the same.
Supply and fixing cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 or equivalent fixed with and including MS stud of suitable size as per manufacturer's instructions, complete all as specified and as directed by the Engineer-in-charge.
Supply and fix solar cat eye aluminum alloy (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600 MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufacturer's instructions etc., complete all as specified and as directed by the Engineer-in-charge.
Material and labour for Thermo Plastic of MOQ 700 Paint for marking on roads of minimum 2 mm thickness, shapes and sizes as per site requirement, applying with machine, complete all as specified and directed by Engineer in charge.
Supply and Install the road delineators of 3m length of approved colour at both sides of the road as per MORTH standards, complete all as specified and directed by Engineer in charge.
Supply and Fix Hand Dryer, complete all as specified and as directed by the Engineer-in-Charge. Make : Euronics EH27 or equivalent model of Dolphy
Material and Labour for Providing & Fixing of 50x70mmx1.5mm thick aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474, including super durable powder coating of 60-801 microns conforming to AMMA 2604 of required colour and shade as approved by the Engineer-in-Charge including fixing of 6mm thick azure blue reflective. ( Refer Architecture Drawing Note: The item inlcudes cost of material such as cleats 3M tape , siliconne sealant, sleeves, screws etc., necessary for fabrication of extruded aluminium frame work, nothing extra shall be paid on this account)
Material and Labour for Expansion Joints by providing and fixing in position 25mm thick pre formed filler in all wall & floor expansion joints after making the joints dust free with high presure air jet cleaners , all complete as per direction of the Engineer-inCharge. (Pre formed joint fillers shall be made of bitumen hot impregantion more than 35% , conforming to IS 1838, including cost of primer, sealing depth as per compound Grade-A in expansion joints, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Powder coated aluminium sheet 2.5 mm thick (minimum thickness of powder coating 50 microns) and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receving dash fasteners, over expansions joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done 75mm long bolt includig providing aluminium washers 2mm thick & 15 mm thick dia at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surfaces and providing expanded plastic sleeves in holes etc., complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 5mm thick plaster in cement mortar (1:3) in 2 Coats using water proofing compound and final coat with potable grade coating for water tank, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Cement Concrete pavement of mix M-40 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vaccum dewatering process and finally finished by floating, brooming with wire brush etc, complete all as specified and as directed by Engineer-In-Charge. Notes: 1. The panel shuttering work shall be paid for separately 2. The cement content considered in this item is @ 400 kg/cum. Excess/less cement used as per design mix is not payable and recoverable separately
Material and Labour for Finishing with Epoxy paint (two or more coats ) at all locations prepared and applied as per maufacturer's specificationns incuding appropiate priming coat, preparation of surface, etc, for floors, complete all as specified and as directed by Engineer-In-Charge.
Material and Labour for construction of 100 Users Septic Tank (Brick masonry with cement mortar 1:4) including excavation in any type of soil, returning filling and removing excavated material beyond MoD land including plastering of internal wall surface with cement mortar 1:4 and RCC cover slab with M-40 Design mix all as per Drg No. DGNP/TD-236 Sheet No. 1/1, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for construction of 50 Users Septic Tank (Brick masonry with cement mortar 1:4) including excavation in any type of soil, returning filling and removing excavated material beyond MoD land including plastering of internal wall surface with cement mortar 1:4 and RCC cover slab with M-40 Design mix all as per Drg No. DGNP/TD-236 Sheet No. 1/1, complete all as specified and as directed by the Engineer-in-Charge.
Supply, fixing, hoisting & commissioning RCC Hume Pipe septic tank (10 users) designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc. all as per Drg No. DGNP/TD/91 Sheet No. 1/1, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Soakage Well (100 Users) with RR masonry with cement mortar 1:4 of size 4.00 m dia and 2.70 m deep including excavation in any type of soil, returning filling and removing excavated material beyond MoD land including RCC cover slab with M-40 Design mix all as per Drg No. DGNP/TD-202 Sheet No. 1/1, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Soakage Well (10 Users) with RR masonry with cement mortar 1:4 of size 2.40 m dia and 1.80 m deep including excavation in any type of soil, returning filling and removing excavated material beyond MoD land including RCC cover slab with M-40 Design mix all as per Drg No. DGNP/TD-202 Sheet No. 1/1, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Soakage Well (50 Users) with RR masonry with cement mortar 1:4 of size 3.00 m dia and 2.40 m deep including excavation in any type of soil, returning filling and removing excavated material beyond MoD land including RCC cover slab with M-40 Design mix all as per Drg No. DGNP/TD-202 Sheet No. 1/1, complete all as specified and as directed by the Engineer-in-Charge.
SUB TOTAL OF SCHEDULE "A" Part - I
SCHEDULE "A" PART - II [INTERNAL ELECTRIFICATION]
Material and Labour for point wiring in concealed/ surface rigid PVC medium grade conduit 20 mm dia, ISI marked, of suitable dia with multistrandard copper conductor cable of size 1.5 sqmm PVC FRLS insulated and PVC sheathed earth continuity conductor of size 1.5 Sqmm including accessories and pressed steel terminal boxes fixed in wall with Modular frame and sheet cover as required fixed by means of brass screw and sunk washers for mounting of surfaces, sockets, regulators etc, for One light controlled by one way switch complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 2.01 above, but add to above item for each additional light point on the same switch circuit (Looping Point)
All as per Item No. 2.01 above, but for One ceiling fan point controlled by one switch and fan regulator button.
All as per Item No. 2.01 above, but for One Exhaust fan point controlled by one switch button.
All as per Item No. 2.01 above, but for One 3 pin 6A socket modular 5/6 Amps independent
All as per Item No. 2.01 above, but for One 3 pin socket outlet 5 amps on the same board with other switches.
Material and Labour for point wiring in concealed/ surface rigid PVC medium grade conduit 25 mm dia ISI marked with multistrandard copper conductor cable of size 2.5 sqmm PVC FRLS insulated and PVC sheathed earth continuity conductor of size 2.5 Sqmm including accessories and pressed steel terminal box for housing 16A switch, socket outlet fixed in wall with Modular frame and sheet cover as required fixed by means of brass screw including 2.5 Sqmm copper cable for earth connectivity conductor complete as per specification for socket point on independent board for 16A switch socket combination, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for flame proof point wiring in concealed / surface with stove enamelled steel conduit of suitable dia with multistrandard copper conductor cable of size 2.5 sqmm PVC FRLSH insulated and PVC sheathed earth continuity conductor of size 2.5 sqmm including accessories and pressed steel terminal box fixed in wall for one light controlled by one flame proof switch, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of Modular switch 1 way 6A, 1 module, complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing of Ceiling rose, 1 phase PVC/ polycarbonate, isolated body complete in all respect with base & necessary hardware, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of Modular socket 2 in 1, 3 pin 5 and 15 Amps flush type universal, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of Modular socket 2 in 1, 5 pin, 5/6 Amps flush type universal, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of Switch flame proof rotary type with termination box in LM6, 16A, Double pole 250V, complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing of Switch flame proof rotary type with termination box in LM6, 25A, Double pole 250V, complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing of Industrial luminaire 40W LED, CRCA, built in electronic driver with THD<10% & lumen efficiency after all losses >= 115 lm/w complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by the Engineer-in-Charge. Cat Part No. DURABS40WLED865SPCSS of make Havells or equivalent model of approved make.
Supply and fixing of luminaire 20W LED, including built in driver with lumen after all losses shall not be less than 115 lm/watt complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and as directed by the Engineer-in-Charge LED batten as per Cat Part No. LUMILINEPLUSNEOBS20WLED865 SPCSSIND and LED rod as per Cat part no. PHOTONULTR A2.01213T8SSTL 20WLED865SPC of make Havells or equivalent model of approved make.
Supply and fixing of Surface mounted bulk head luminaire 10W LED complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and as directed by the Engineer-in-Charge Cat Part No. HEXP FT10WLED85 7SSY MBOPC of make Havells or equivalent model of approved make.
Supply and fixing of flameproof light fitting 40W LED complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and as directed by the Engineer-in-Charge. Cat Part No. JETAALBAFLOODLIGHT70W of make Havells or equivalent model of approved make.
Supply and fixing of Highbay luminaire 120W LED, efficiency (100lm/w) after all losses, complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and as directed by the Engineer-in-Charge. Cat Part No. PARABELLOHBP120WLED857PBOTG of make Havells or equivalent model of approved make.
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for IP 65 protection with impact and corrosion resistant complete with driver and lamp, complete all as specified and as directed by the Engineer-in-Charge. Cat Part No. RUBYPT40WLED757PSYMTOPC of make Havells or equivalent model of approved make.
Supply and fixing well glass LED type 40 watt 230 watt volts light IP 65 protection with impact and corrosion resistant complete with driver and lamp, complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing round shape 18 watt 220 volts AC recessed type with high efficiency PPC diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by the Engineer-in-Charge. Cat Part No. INTEGRANXTRDDLRSURD18WLED830S of make Havells or equivalent model of approved make.
Supply and fixing LED light fittng mirror type with high out put diffuser 2 feet, 15 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by the Engineer-in-Charge. Cat Part No. PLUOTSURFACEIXIPLS15WLED840S of make Havells or equivalent model of approved make.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and as directed by the Engineer-in-Charge. Cat Part No. DROPDOWNFLAT2X2PLR36WLED830S of make Havells or equivalent model of approved make.
Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PCA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by the Engineer-in-Charge. Cat Part No. INTEGRAPLUSDLRD12WLED840 of make Havells or equivalent model of approved make.
Supply and fixing of Fire Exit Sign (illuminated) with LED,with upto 3 Hrs Battery Backup, complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing ceiling fans complete with blades, down rods, electronic regulatorand accessories, 230 V, 1200 mm sweep with Minimum air delivery 210 CFM with service value 6.00 BEE Five star rated with brushless direct current motor (BLDC), complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing of AC single Phase, 230V exhaust fan (300mm sweep), steel body with blades, frame, louvers including cutting hole in wall of proper size & making good , complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing 6 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts,with 200 Amps rated bus bar double door on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc., complete all as specified and as directed by the Engineer-in-Charge.(But without MCB/RCCB/Isolator)
Supply and fixing 8 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts,with 200 Amps rated bus bar double door on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required, complete all as specified and as directed by the Engineer-in-Charge (But without MCB/RCCB/Isolator)
Supply and fixing 10/12way, single pole and neutral, sheet steel, MCB distribution board, 240 volts,with 200 Amps rated bus bar double door on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc., complete all as specified and as directed by the Engineer-in-Charge (But without MCB/RCCB/Isolator)
Supplying and fixing 6 way, horizontal/Vertical type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. , complete all as specified and as directed by the Engineer-in-Charge (But without MCB/RCCB/Isolator)
Supplying and fixing 8 way, horizontal/Vertical type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc., complete all as specified and as directed by the Engineer-in-Charge. (But without MCB/RCCB/Isolator)
Supplying and fixing 12 way, horizontal/Vertical type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. , complete all as specified and as directed by the Engineer-in-Charge. (But without MCB/RCCB/Isolator)
Supply and fixing 32A, Double pole, 240V, 10KA 'C' curve miniature circuit breaker MCB with connection testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 40A, Double pole, 240V, 10KA 'C' curve miniature circuit breaker MCB with connection testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 63A, Double pole, 240V, 10KA 'C' curve miniature circuit breaker MCB with connection testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 40A, Triple pole& Neutral, 415V, 10KA 'C' curve miniature circuit breaker MCB complete with connection testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 63A, Triple pole& Neutral, 415V, 10KA 'C' curve miniature circuit breaker MCB complete with connection testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 5 to 32A, single pole, 240V, 10KA 'C' curve miniature circuit breaker MCB complete with connection testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole 20 Amp MCB, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole 32 Amp MCB, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32A, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole 20 MCB, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 100A, Triple pole & Neutral, 415V, 10KA 'C' curve miniature circuit breaker MCB complete with connection testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 125A, Triple pole & Neutral, 415V, 10KA 'C' curve miniature circuit breaker MCB complete with connection testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 100A, Triple pole & Neutral, 415V, 16KA MCCB enclosure complete with connection testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 125A, Triple pole & Neutral, 415V, 16KA MCCB enclosure complete with connection testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying for 3 core x 2.5 sqmm copper cable for External lighting fixtures (from junction box to lighting fixture), complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying of Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core multi stranded cable in surface/ recessed/ consealed as required in steel conduit of 2x2.5 sq. mm + 1x2.5 sq. mm earth wire (for HIGHBAY lighting) complete all as specified and as directed by the Engineer-in-Charge, Note : Two/four runs of cable, one/two run of earth wire and one run of conduit shall be measured and paid as one unit length.
All as per Item No. 2.52 above, but of 2x4.0 sq. mm + 1x4.0 sq. mm earth wire (for power points)
All as per Item No. 2.52 above, but of 2x6.0 sq. mm + 1x6.0 sq. mm earth wire (for industrial sockets & AC points)
All as per Item No. 2.52 above, but of 2x10.0 sq. mm + 1x10.0 sq. mm earth wire (for UPS distribution boards)
All as per Item No. 2.52 above, but of 2x16.0 sq. mm + 1x16.0 sq. mm earth wire
All as per Item No. 2.52 above, but of 4x4.0 sq. mm + 2x4 sq. mm earth wire ( 20A 3-phase Industrial sockets)
All as per Item No. 2.52 above, but of 4x6.0 sq. mm + 2x6.0 sq. mm earth wire ( 32A 3-phase Industrial sockets)
All as per Item No. 2.52 above, but of 4x10.0 sq. mm + 2x10.0 sq. mm earth wire
All as per Item No. 2.52 above, but of 4x16.0 sq. mm + 2x16.0 sq. mm earth wire
Supplying and installing 100 mm width X 50 mm depth X 1.6 mm thickness perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc., complete all as specified and as directed by the Engineer-in-Charge
All as per Item No. 2.61 above, but size 150 mm width X 50 mm depth X 1.6 mm thickness
All as per Item No. 2.61 above, but size 300 mm width X 50 mm depth X 1.6 mm thickness
All as per Item No. 2.61 above, but size 450 mm width X 50 mm depth X 2.0 mm thickness
All as per Item No. 2.61 above, but size 600 mm width X 75 mm depth X 2.0 mm thickness
All as per Item No. 2.61 above, but size 900 mm width X 75 mm depth X 2.0 mm thickness
Supplying and installing 100 mm width X 50 mm depth X 1.6 mm thickness perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. a, complete all as specified and as directed by the Engineer-in-Charge
All as per Item No. 2.67 above, but size 150 mm width X 50 mm depth X 1.6 mm thickness
All as per Item No. 2.67 above, but size 300 mm width X 50 mm depth X 1.6 mm thickness
All as per Item No. 2.67 above, but size 450 mm width X 50 mm depth X 2.0 mm thickness
All as per Item No. 2.67 above, but size 600 mm width X 75 mm depth X 2.0 mm thickness
All as per Item No. 2.67 above, but size 900 mm width X 75 mm depth X 2.0 mm thickness
Supplying and fixing of Rigid non-metallic 20mm PVC conduit medium grade exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (For Data, Telephone, Fire Alarm), complete all as specified and as directed by the Engineer-in-Charge
All as per Item No. 2.73 above, but 25mm conduit
All as per Item No. 2.73 above, but 32mm conduit
Supplying and fixing modular switch/ socket for Telephone socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. , complete all as specified and as directed by the Engineer-in-Charge
All as per Item No. 2.76 above, but for RJ 45 cat 6 jack point
Material and Labour for 1 Modular White Cover Plate with frame, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for 1/2 module (75mm x75mm) modular metal flush box, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of Highbay luminaire - 100W LED complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by the Engineer-in-Charge. Cat Part No. SAUCER NEXTGENXPROHBP 100WLED 757P90DBOLTG of make Havells or equivalent model of approved make.
SUB TOTAL OF SCHEDULE "A" Part - II
SCHEDULE "A" PART - III [ CHILLER PLANT]
Supply, Installation, Testing and Commissioning of AHRI Certified Water Cooled Screw chiller with VFD each having a minimum Actual capacity of 115 TR at chilled water inlet/outlet temperature of 54°F/44°F with chilled water circulation rate of 276 USGPM and condenser water inlet/outlet temperature of 90°F/100°F with water circulation rate of 460 USGPM , suitable for operation on refrigerant R-134a for screw type machine each comprising of the following complete as per specifications and as required. Quoted price shall include price of Variable Frequency Drive starter of suitable capacity, complete all as specified and as directed by the Engineer-in-Charge . Twin rotor based semi-hermetic type single/ multiple horizontal compressor complete with automatic capacity control from 100%-20%, safety switches, forced feed lubrication system etc, as per specifications Suitable capacity squirrel cage induction motor with class 'B' insulation suitable for operation on 400+/-10% volts, 50Hz, A.C. supply. Unit mounted IP 54 rated VFD Starter of suitable capacity Necessary drive arrangement. 1 set - Lubrication device consisting of automatic electric oil pump, oil cooler, head tank, oil strainer, and automatic pressure regulating valve, oil heater, oil heater thermal switch etc. as per specifications. 1 no. - matching shell and tube type even pass water cooled condenser of M.S. shell and integrally finned copper tubes and pressure drop not exceeding 10 metres
Item No. 3.001(Contd) 1 no. - matching shell & tube flooded/falling film type even water pass chiller for screw type units of MS shell and copper tubes and pressure drop not exceeding 10.0 metres Evaporator and condenser shall be manufactured, tested and stamped with ASME(U) pressure vessel code. 1 Lot - Refrigerant piping fittings, valves and accessories to inter connect compressor, condenser, chiller and expansion valve. 1 set - Microprocessor based control panel complete with accessories as per specifications. Lot - Refrigerant line accessories comprising of safety valves, angle valve, liquid line indications, liquid level control etc. Lot - Water flow switches at outlet of condenser & chiller, water drain, air purge valves, thermometers and pressure gauges wherever required. Lot - Suction line and chiller insulation with minimum 19 mm thick polyvinyl nitrile rubber insulation complete as required. Lot- Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with anti-vibration pads/springs. Lot- Initial/first charge of refrigerant gas & compressor oil shall be factory charged.
Supply, installation, testing and commissioning of PN16 rated Vertical Inline Split Coupled (with rigid aluminium alloy coupling between pump shaft and motor shaft) single stage centrifugal pump each capable of delivering the specified flow rate comprising the following and complete as per specifications. Casing (Volute) - Cast Iron. Impeller - Gunmetal Bronze - Statically and Dynamically Balanced Casing Gasket - Confined Non Asbestos Fiber Pump Shaft - SS 416. Flush Line - Braided Stainless Steel Mechanical Seal - Outside Balanced (the pump design shall meet the requirement of servicing / changing the mechanical seal without disturbing the pump shaft alignment) Motor Type - TEFC Squirrel Cage, Efficiency Class - IE2, Insulation - Class F, 415V ± 10% , 50Hz ± 5%, 3Ø AC Power Supply Vertical Inline Split Coupled PN16 centrifugal pump. Right angle Suction guide with inbuilt guide vanes & strainer of Cast Iron body.To be supplied by pump manufacturer for unit responsibility. Flow rate 276 USGPM and 15 METER head
Supply, installation, testing and commissioning of PN16 rated Vertical Inline Split Coupled (with rigid aluminium alloy coupling between pump shaft and motor shaft) single stage centrifugal pump each capable of delivering the specified flow rate comprising the following and, complete all as specified and as directed by the Engineer-in-Charge. Casing (Volute) - Cast Iron. Impeller - Gunmetal Bronze - Statically and Dynamically Balanced Casing Gasket - Confined Non Asbestos Fiber Pump Shaft - SS 416. Flush Line - Braided Stainless Steel Mechanical Seal - Outside Balanced (the pump design shall meet the requirement of servicing / changing the mechanical seal without disturbing the pump shaft alignment) Motor Type - TEFC Squirrel Cage, Efficiency Class - IE2, Insulation - Class F, 415V ± 10% , 50Hz ± 5%, 3Ø AC Power Supply VFD - Integrated Mounted over Pump motor for sensorless/ wireless DPT control with IP-55 Protection, Integrated fliter to meet EN61800-3 for RFI Control, Integrated DC link Reactor equivalent in performance to a 5% AC line reactor. The VFD LCD should display the dynamic head & flow rate at any point of operation. Flow rate 276 USGPM and 30 METER head
Supply, installation, testing and commissioning of PN16 rated Vertical Inline Split Coupled (with rigid aluminium alloy coupling between pump shaft and motor shaft) single stage centrifugal pump each capable of delivering the specified flow rate comprising the following and , complete all as specified and as directed by the Engineer-in-Charge Casing (Volute) - Cast Iron. Impeller - Bronze - Statically and Dynamically Balanced Casing Gasket - Confined Non Asbestos Fiber Pump Shaft - SS 416. Flush Line - Braided Stainless Steel Mechanical Seal - Outside Balanced (the pump design shall meet the requirement of servicing / changing the mechanical seal without disturbing the pump shaft alignment) Motor Type - TEFC Squirrel Cage, Efficiency Class - IE3, Insulation - Class F, 415V ± 10% , 50Hz ± 5%, 3Ø AC Power Supply Capacity of each pump (LPM) 2646 Pump Head (Mt) 25 Pump Efficiency Not less than 75% Maximum Permissible Speed 1450 RPM HP of Motor 20
Supply,installation, testing &commissioning of FRP induced draft cooling tower of capacity 175 TR (529200 Kcal/Hr) complete with sump & steel ladder, EFF 2 type fan motors suitable for 415 V, 3 phase, 50 Hz. MS Structure for mounting Cooling Tower, access arrangement for cooling tower interior, cement concrete foundation, stel / masonry support structure, anti vibration mountings etc. The starter, isolating switch & panel near cooling tower to be included in main electrical panel price, i.e. in the Detailed Bill of Quantities). The cooling tower shall conform to technical specifications Section. It should be complete as per directions of Engineer-In-Charge. (2Working +1 Stand By) Sound Level 75dB at 1Mt Inlet Water Temperature 36.39 °C Outlet Water Temperature 32.22 °C HP of C/T Fan Motor 2 x 7.5HP
Supply, installation, testing and commissioning of Electric Hot Water Generator of vertical construction equipped with sufficient number of flanges and electric immersion heaters. The pressure vessel shall be constructed as per ASME standards and insulated on all sides with 50 mm thick fiberglass with 0.60mm Aluminum cladding as per specifications. The hot water generator shall be equipped with all automatic and safety controls such as high temperature water thermal cutout, Low water level cut-off, PLC, HMI other controls as per tender specifications. The hot water generator shall be control by PLC based Step controller and HMI screen and BMS compatible having Ethernet/RS485 Port. All basic controls and terminals shall be located in an integral control cabinet factory wired and tested. The hot water generator shall be suitable for 415 volts,50 Hz, 3phase power supply.The entire hot water generator shall be factory assembled and tested. Note: a. Water ‘IN’ temperature : 45 deg C. b. Water ‘OUT’ temperature : 50 deg C 3 Nos 50 Kw(2w+1s)
Supply, installation, testing and commissioning of PN16 rated Vertical Inline Split Coupled (with rigid aluminium alloy coupling between pump shaft and motor shaft) single stage centrifugal pump each capable of delivering the specified flow rate comprising the following and complete as per specifications. Casing (Volute) - Cast Iron. Impeller - Gunmetal Bronze - Statically and Dynamically Balanced Casing Gasket - Confined Non Asbestos Fiber Pump Shaft - SS 416. Flush Line - Braided Stainless Steel Mechanical Seal - Outside Balanced (the pump design shall meet the requirement of servicing / changing the mechanical seal without disturbing the pump shaft alignment) Motor Type - TEFC Squirrel Cage, Efficiency Class - IE2, Insulation - Class F, 415V ± 10% , 50Hz ± 5%, 3Ø AC Power Supply 3cNos. (2W+1S) Vertical Inline Split Coupled PN16 centrifugal pump Right angle Suction guide with inbuilt guide vanes & strainer of Cast Iron body.To be supplied by pump manufacturer for unit responsibility. Flow rate 80 USGPM and 15 METER head (2W+1S)
Supply, installation, testing & commissioning of Micro bubble Air & Dirt Separator capability, automatic air purging arrangement etc.The shell shall be constructed of mild steel with coalescence. It shall work on the principle of coalescence.The water velocity shall not Exceed 1.5m/sec.The M.S shall to be fabricated or other similar standard.The inlet and outlet connections shall be flanged. It shall be provided with a high capacity auto air vent at the top and a drain valve at the bottom.Matching flanges, high tensile bolts & nuts and gasket shall be also provided By the manufacturer. it shall be duly insulated 32mm thick class O Nitrile rubber insulation complete as per specifications.The design parameters for the air separator of efficiency 96-98 %, should be as follows with Safety working pressure:3.5 bar (32mm thick insulation) Line Size:300 mm diameter CUBICAL PANEL BOARD FOR HIGH SIDE EQUIPMENTS 3 No.s 115 TR Water Cooled Screw Chiller (2 No.s Working + 1 No. of stand by) 3 No.s Primary Pumps ( 2 No.s Working + 1 No. of stand by) @ 15 HP 3 No.s secondary pumps ( 2 No.s Working + 1 No. of stand by) @ 30 HP 3 No.s CDW Pumps ( 2 No.s Working + 1 No. of stand by) @ 20 HP 3 No.s 175TR C/T ( 2 No.s Working + 1 No. of stand by) (2x5.5 HP) 3 No.s 50 KW Hot Water Generator (2 No.s Working+1no of stand by) 3 No.s Hot Water Pumps (2 No.s Working + 1 No. of stand by) @ 15 HP
Supply, installation,testing & commissioning of Micro bubble Air & Dirt Separator capability,automatic air purging arrangement etc.The shell shall be constructed of mild steel with coalescence. It shall work on the principle of coalescence.The water velocity the shall not Exceed 1.5m/sec.The M.S shall to be fabricated or other similar standard.The inlet and outlet connections shall be flanged. It shall be provided with a high capacity auto air vent at the top and a drain valve at the bottom. Matching flanges, high tensile bolts & nuts and gasket shall be also provided By the manufacturer.It shall be duly insulated 32mm thick class O Nitrile rubber insulation complete as per specifications.The design parameters for the air separator of efficiency 96-98 % should be as follows with Safety working pressure:3.5 bar (32mm thick insulation) Line Size:100 mm diameter CUBICAL PANEL BOARD FOR HIGH SIDE EQUIPMENTS 3 No.s 115 TR Water Cooled Screw Chiller (2 No.s Working + 1 No. of stand by) 3 No.s Primary Pumps ( 2 No.s Working + 1 No. of stand by) @ 15 HP 3 No.s secondary pumps ( 2 No.s Working + 1 No. of stand by) @ 30 HP 3 No.s CDW Pumps ( 2 No.s Working + 1 No. of stand by) @ 20 HP 3 No.s 175TR C/T ( 2 No.s Working + 1 No. of stand by) (2x5.5 HP) 3 No.s 50 KW Hot Water Generator (2 No.s Working+1no of stand by) 3 No.s Hot Water Pumps (2 No.s Working + 1 No. of stand by) @ 15 HP
Design, Manufacture, Supplying, Transport to the site, Receiving, Unloading, Shifting to various locations, handling, assembling, installation in correct aligned position, grouting with dash fasteners, GI nuts-bolts, testing and commissioning of Totally Type Tested Panels (Form-4B construction) complying to IEC:61439 -1/2 cubical with Internal arc withstand of 50kA for 0.3 second and minimum impact resistance IK10 as per IEC:62262 with each compartment front unbreakable glazed door cover and back solid door. The degree of protection of minimum IP:42 for indoor and IP:65 for outdoor use. Panels shall be tested for an Impulse Withstand Voltage of 12kV. Suitable for 415V, 3Phase, 4 Wire 50 Hz Ac supply system bolted fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plate, bottom base channel of MS section not less than 100mmx 50mmx50mmx 5mm thick for Main L.T. Panel and capacitor panels and 40mmx25mmx25mmx 5mm thickplates for MDB/MCC and SDBs etc., complete all as specified and as directed by the Engineer-in-Charge. including cleaning & finishing complete, SMC bus bar supports, with short circuit withstand capacity of minimum 50kA for 1 Sec., fabrication shall be done in transportable sections and all front and back doors shall be hinged type and earth with frame, Entire panel shall have a common copper contineous earth bar of size 40mm x 6mm or as specified below at the rear with 2 Nos. earth stud each side, solid inter connections from main bus bar to switch gears upto cable alley with required size. bus bars and insulated control wiring with suitable size of FRLS PVC insulated copper conductor cable, cable alleys, cable gland plates in two half, incl. providing following switch gears :-
Supply, installation, testing and commissioning of factory fabricated Double Skinned Chilled Water Air- handling unit Floor Mounted type fabricated with forward curve fan of static 50 mm out of extruded aluminium section with 0.63mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.63 mm plain Galvanised steel sheet inside with blower, Plug fan /blower section and direct driven / blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 6 Row cooling coil made of Aluminium finned Copper tube with coil section,with following filtration level, polished stainless steel drain pan made out of 22 G sheet duly insulated complete with motor and belt drive package etc. without face and bypass dampers. The AHU panels shall be insulated with 23 mm thick & 36 Kg/m³ density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only, complete all as specified and as directed by the Engineer-in-Charge. (a)The face velocity across cooling coil shall be limited to 152 MPM maxm. (b)Pre-filter section with Pre filter(10 Micron & 90 % Efficiency) in All following AHUS (c)Fan Oulet Velocity Not to Exceed 10 m/s (d)6 RD Cooling Coil(CC) (e)2 RD Heating Coil(HC) The complete AHU shall confirm to above & standard specification. The capacity of Air-handlers shall be as follows: FM AHU 1x25500 CFM/68.75 TR /50 MM STATIC
Supply , installation, testing & Commissioning of 1x1.0 TR, DX type split AC units with air cooled condenser mounted in outdoor unit complete with scroll/rotary compressor ,condensor, wiring & accessories . Indoor units shall be wall mounted type complete with evaporator, fan, filter, drier, expansion devices & microprocessor control panel along with all accessories with refrigerant & oil charge , cordless remote controls. The unit shall be suitable for working, 50 cycle /second ,1 phase AC supply .The unit shall be designed to take care of veritcal head 4mt & horizontal length of 30 mt & necessary oil seprator shall be included, Necessary supporting arrangement for both indoor & outdoor units ( Powder Coated /Epoxy painted MS stand for ODU units as per approved make shade by Architect) with necessary vibration isolation arrangement as per site condition etc.( without condensate drain pipe ,electrical pipe ,electrical power & control cabling between indoor & outdoor unit which shall be paid seprately ), complete all as specified and as directed by the Engineer-in-Charge. Notes: All Unit shall be Minimum 5 Star Rating Based The Outdoor unit Compressor must be provided with 5 Year Warranty Period. Dust Filter
Item No. 3.012(Contd) Civil Work such as wall hole making, wall chisling, refilling of chiseling part with mortar etc as per site condition. Nitrogen pressure testing for leakages & flushing during installation & after commissioning between IDU & ODU with flar nuts Removable Covers for all indoor & Outdoor units shall be supplied & put on the units after installation & commissioning. Incoming power supply shall be provided near each indoor units
All as per Item No. 3.012 above, but 1x1.5 TR Dx Type split AC units
All as per Item No. 3.012 above, but 1x2.0 TR Dx Type split AC units
Supply, installation, testing and commissioning of copper refrigerant piping (Two Length) for 1.0. TR Dx type Hi wall Unit -Copper Pipe, duly insulated with 9mm thick nitrile rubber of Class "O" between the above indoor & outdoor units as shown on drawing enclosed with necessary supports etc 1/2 inch & 5/8 for 4TR , 9/8 & 5/8 for 8.5 TR or as per manufacture std, complete all as specified and as directed by the Engineer-in-Charge
All as per Item No. 3.015 above, but for 1.5 TR Dx type Hi wall Unit -Copper Pipe
All as per Item No. 3.015 above, but for 2.0 TR Dx type Hi wall Unit -Copper Pipe
Supply, installation, testing and commissioning of 3LPH ultrasonic type Humidification package with Humidistat with all necessary control cabling as required , complete all as specified and as directed by the Engineer-in-Charge of following capacities:
All as per Item No. 3.018 above, but 5LPH
Supply, Installation , testing , commissioning and handing over of the coil mounted HYBRID Ultra Violet Germicidal Irradiations ( UVGI) System for maintaining indoor Air Quality in indoor units. The system should be capable of reducing the airborne as well as surface bacteria, virus, mold, etc. The system should be designed to achieve kill rate of not less than 90% per pass. The HYBRID UV system shall be designed to provide UV dosage of 2000 micro W/cm2 and should produce equal amount of positive & negative reactive oxygen species based on bi-polar plasma ionization to actively reduce the airborne & surface borne pathogens and other chemical gasses such as VOCs. The lamp shall have minimum 9000 working hrs life, ballasts shall be electronic type, life rated grater than 15000 starts. The lamp used should be T5 type, quartz glass, bi-pin type with ceramic ends. High quality aluminium reflector should be the part of the system. An run hour meter shall be provided to indicate remaining life of the Lamp in the form timer of digital display. Minimum UV intensity should be 500 microwatts at all the corners of the cooling coil. Minimum 4ft length of the duct should be covered with UV lights.Should follow IEC 61347-2-3, IEC 61000-3-2, IEC 61547, safety standards.Should follow IEC 60929, IEC68-2-6 Fc, IEC 68-2-29 Eb The lamps should be ISO Certified and plasma ionizers should be UL listed.The vendor should conduct bacteria test or bio test in any 2 locations to be done before and after installation, complete all as specified and as directed by the Engineer-in-Charge. Note: All AHU,fcu and duct type unit should be with UVGI, Upto 5000 CFM
Supply, installation, testing & commissioning of wall mounted Propellar fans suitable for single phase, 230 volts, 50Hz AC supply of 300mm dia, complete all as specified and as directed by the Engineer-in-Charge. Note: All Fans should be AMCA certified
Supply, installation, testing and commissioning of ceiling suspended Inline fans (Rectangular/Round casing) complete with bird screen, rain guard, metal clad MCB & starter ,5m length copper cable, earthing wire all compete as required of following capacities as per specification and shop drawing mentioned, complete all as specified and as directed by the Engineer-in-Charge. Notes: (a) All Fans should be AMCA certified (b) Capacity: 1500 CFM (c) Static Presure : 20 mm Of wg (d) Kw : 0.7 KW
Supply, installation, shifting, loading, unloading, testing & commissioning of Floor mounted, double flanged, long casing (motor should completly accomodated in Fan casing) Vane/tube axial flow fans with sound attenuator (Fire Rated) AMCA Certified, with adjustable pitch blade & angle, bird screen at fan outlet , MS/GI casing, cast aluminium alloy impeller complete with TEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 4/6/8 pole, three Phase, A.C supply class "H" /S insulation with support, Phase& Motor rated Value IP55 . Motor shall be Thermally Rated for 250 deg C for 2 Hours should be certified as per BSEN12101-3:2002 standard & direct driven for smoke extraction fans , complete all as specified and as directed by the Engineer-in-Charge. With the Approx. Motor HP as given below The rate shall include supply and fitting of vibration isolators ( spring & rubber pads) complete as per specifications and drawings including fitting of accessories like Fire retardant canvass connection painting,gravity louver,bird screen etc. as required at site of work. Including all type of civil work like cutting/holes/chasing/cut out in brick wall etc Sound attenuator shall be as specified with following characteristics: a) Length not exceeding 1D (Fan Dia.) b) Pressure drop through through sound attenuator shall not exceed 8mm WC
Supplying, laying/ fixing, testing and commissioning of 350 mm dia, 6 mm thick (75mm thick Insulation) MS PIPE of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/ cum density resin bonded fiber glass or 144 Kg / cum density mineral wool insulation (non combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying star bond coating and repairing of damage to building etc. , complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 3.024 above, but 300 mm dia, 6 mm thick (75mm thick Insulation) MS PIPE
All as per Item No. 3.024 above, but 250 mm dia, 6 mm thick (75mm thick Insulation) MS PIPE
All as per Item No. 3.024 above, but 200 mm dia, 6 mm thick (75mm thick Insulation) MS PIPE
All as per Item No. 3.024 above, but 150 mm dia, 5.4 mm thick (50mm thick Insulation) MS PIPE
All as per Item No. 3.024 above, but 125 mm dia, 5.4 mm thick (50mm thick Insulation) MS PIPE
All as per Item No. 3.024 above, but 100 mm dia, 5.4 mm thick (50mm thick Insulation) MS PIPE
All as per Item No. 3.024 above, but 80 mm dia, 4.8 mm thick (50mm thick Insulation) MS PIPE
All as per Item No. 3.024 above, but 65 mm dia, 4.5 mm thick (50mm thick Insulation) MS PIPE
All as per Item No. 3.024 above, but 50 mm dia, 4.5 mm thick (50mm thick Insulation) MS PIPE
All as per Item No. 3.024 above, but 40 mm dia, 4 mm thick (50mm thick Insulation) MS PIPE
All as per Item No. 3.024 above, but 32 mm dia, 4 mm thick (50mm thick Insulation) MS PIPE
All as per Item No. 3.024 above, but 25 mm dia, 4 mm thick (50mm thick Insulation) MS PIPE
Supplying, fixing, testing & commissioning 250 mm Dia (75 MM Thick Insulation ) Butterfly Valve Wafer Type Butterfly Valves, in the chilled/Hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported, Ductile (SG) Iron Body & Disc SS-431 Shaft EPDM Integrally Moulded Liner with Hand Lever Operated upto size 150mm, 200mm & above Gear Operated Pressure Rating PN16 complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 3.037 above, but 150 mm Dia (50 MM Thick Insulation )
All as per Item No. 3.037 above, but 125 mm Dia (50 MM Thick Insulation )
All as per Item No. 3.037 above, but 100 mm Dia (50 MM Thick Insulation )
All as per Item No. 3.037 above, but 65 mm Dia (50 MM Thick Insulation )
All as per Item No. 3.037 above, but 50 mm Dia (50 MM Thick Insulation )
All as per Item No. 3.037 above, but 40 mm Dia (50 MM Thick Insulation )
All as per Item No. 3.037 above, but 32 mm Dia (50 MM Thick Insulation )
Supplying, fixing, testing & commissioning of 150 mm Dia (75 MM Thick Insulation ) Balancing Valve in the chilled/Hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported, with built in measuring facility, CI Body, flanged construction with EPDM coated disc with long pitch, protected out pipe insulation & PN 16 pressure rating for chilled/Hot water circulation complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 3.045 above, but 125 mm Dia (50 MM Thick Insulation )
Supplying, fixing, testing & commissioning of 125 mm Dia (50 MM Thick Insulation ) "Y"strainer of ductile CI Body flanged ends stainless steel strainer fin the chilled/Hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported, complete all as specified and as directed by the Engineer-in-Charge
All as per Item No. 3.047 above, but 65mm Dia (50 MM Thick Insulation )
All as per Item No. 3.047 above, but Pot Strainer of 350 mm dia.
Supplying, fixing, testing & commissioning of 125 mm Dia (50 MM Thick Insulation ) Non- return Valve with dual plate of CI Body SS Plates vulcanised NBR seal flanged end & PN16 pressure rating in the chilled/Hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported, complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 3.050 above, but 65mm Dia (50 MM Thick Insulation )
Supplying, fixing, testing & commissioning of Pot Strainer 350 mm dia, complete all as specified and as directed by the Engineer-in-Charge
Supplying, fixing, testing and commissioning of SG Iron Body flow switch with necessary control wiring and interlocking at Condenser Water Pump, complete all as specified and as directed by the Engineer-in-Charge.
Supplying, installation, testing and commissioning of on line scale preventer suitable for 350mm Dia and flow rate with necessary fittings and accessories, complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of test points in brass / bronze construction with non return ring complete with suitable size socket on insulated lines complete nipples etc. as required for measurement of pressure and temperature, complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of digital thermometer with adopter for above test point, complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of digital Pressure gauge with adopter for above test point, complete all as specified and as directed by the Engineer-in-Charge.
Supplying, fixing, testing & commissioning of 50mm Non- return Valve with dual plate of CI Body SS Plates vulcanised NBR seal flanged end & PN16 pressure rating in the chilled/Hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported, complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 3.058 above, but 40mm
All as per Item No. 3.058 above, but 25mm
Supply, installation, testing and commissioning of aluminium cladded open type expansion tank made out of 5 mm thick MS sheet of size 1.0m x1.0m x 1.0m inner surface area and painting with epoxy paint two coats to avoid rust duly insulated with 80mm thick(40mm in two layers ) expanded polystrene P quality with all accessories, valves & fittings for chilled water, complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of 100mm Butterfly Valve, PN 16 rating, duly insulated with Al Cladded valves etc, complete with companion flanges, nuts ,bolts , gaskets etc., complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of 100mm Balancing Valve, PN 16 rating, duly insulated with Al Cladded valves, complete with companion flanges, nuts ,bolts , gaskets etc, complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of "Y" type strainer of 100mm, PN 16 rating, duly insulated with Al Cladded valves etc, complete with companion flanges, nuts ,bolts , gaskets etc, complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing & commissioning of motorised 2 way Modulating Valve of 100mm dia complete with electrical actuator, heavy duty PN10 cast iron body with nylon coated S.G. iron disk, water sealant lining, stainless steel shaft, control lever with thermostat control wiring, accessories if any like transformer etc.position confirming to standard specification, complete all as specified and as directed by the Engineer-in-Charge.
Supply, Installation, Testing, & Commissioning of 15 mm dia Automatic air vent with ball valve in brass construction complete with nipples, union etc. as required at all high points in the pipe lines. The valve shall be such as to have non-return valve as integral part of the vent, complete all as specified and as directed by the Engineer-in-Charge.
Supply, Installation, Testing & Commissioning of 25mm diameter Drain Valves in dirt legs complete with nipples as per specifications, complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation , testing & commissioning of 50mm bore nitrile rubber Class O insulated condensate drain water piping of GI 'Medium' class complete with Medium Class fittings like elbows, tees, reducers bends, MS flanges, supports, welding, painting etc. as required conforming, complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 3.068 above, but 40 mm bore pipe
All as per Item No. 3.068 above, but 32 mm bore pipe
All as per Item No. 3.068 above, but 25 mm bore pipe
All as per Item No. 3.072 above, but 0.80 mm sheet duct
All as per Item No. 3.072 above, but 1.00 mm sheet duct
All as per Item No. 3.072 above, but 1.25 mm sheet duct
Supply, Fabrication, installation and testing of 0.63mm GSS sheet metal ducts & finally applying fire rated paint as per BS 476 Part 24 (Site FABRICATED DUCTS For Connection /Plenum etc.) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods , anchor bolts, GI bolts & nuts, etc., as per specifications, complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 3.076 above, but 0.80 mm sheet duct
All as per Item No. 3.076 above, but 1.00 mm sheet duct
All as per Item No. 3.076 above, but 1.25 mm sheet duct
Supply, fabrication, installation and testing of 50 micron powder coated, aluminum extruded linear fixed horizintal bar/grill/Diffusers with all side flanges as per approved shop drawings, complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of GI volume control duct dampercomplete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc,as per specifications.(18G), complete all as specified and as directed by the Engineer-in-Charge.
Supply, Installation and Testing of 50 micron powder coated, Al extruded volume control damper for collor to be provided with suitable links and quadrants for control of volume of air, complete all as specified and as directed by the Engineer-in-Charge.
Supply, fabrication, installation and testing of 50 micron powder coated, aluminum extruded fresh air louvers with bird screen & Al volumne control damper with all side flanges as per approved shop drawings, complete all as specified and as directed by the Engineer-in-Charge.
Supply, Installing, testing of fire retardant flexible canvass connector 200 mm deep made of imported FIBER GLASS WEAVE fabric with Silicon Rubber Coating & 30 mm Extruded Aluminum Frame, complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing & commissioning of Duct/Wall mounted multi blade, motorised fire & smoke dampers with spring return actuator. The damper shall be of atleast 1.5 hr. fire rating and actuated with the help of 24 V electric actuator. The damper shall be as per UL listed UL 555; 1995 and CBRI approved. The damper shall be constructed out of 16G galvanised steel sheet & as per specification with Control Cable to Potential Free Contact for tripping of AHU fan motor, complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of Motorised Spring Return Actuator for devices upto 0.8 sq. metre with with control panel & temperature sensor, complete all as specified and as directed by the Engineer-in-Charge.
Supply and Application of 15 mm thickness (Internal Lining of Ducts), Acoustic Insulation Inside the Duct with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7 and with built-in EPA approved Microban antimicrobial protection; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents. , Metal Strips and Anchor Fasteners as per design, complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 3.087 above, but 25 mm thickness (Internal Lining of Ducts)
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms & plant room with Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7 and with built-in EPA approved Microban antimicrobial protection; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents. , Metal Strips and Anchor Fasteners as per design, complete all as specified and as directed by the Engineer-in-Charge.
Supply & Installation of Thermal Insulation on Duct exposed to sunlight using Closed Cell Anti Microbial and Anti Fungal Class O Nitrile Rubber Elastomeric Insulation of Density 40 - 60 Kg/m3, Thermal Conductivity of 0.035 W/mk at 200 Celcius Mean Temp. and Mu≥10000 and with Chemically treated Factory Laminated Woven Fibre Glass Cloth with 200+/-20 gsm using manufacturer's recommended Rubber based Adhesive in a blend of solvents complete as per Specifications with Roof Insulation with 25 mm thick Class O Nitrile Rubber Insulation with GC cloth, complete all as specified and as directed by the Engineer-in-Charge.
VFD for Fan Motor with IP 20 enclosures, Mains disconnect, Built-in Harmonic Filters, EMC Filters (Electromagnetic Compatibility Filters), 3 PID Controlers, Automatic Energy Optimization / Load dependent flux optimization functionality for maximum energy savings & complying with the tender specifications. The price quoted for supply, installation, testing & commissioning shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. Fan 20 HP
Supplying and fixing weather proof isolator with suitable rating near each unit, the prices should be inclusive of copper cabling from isolators to outdoor units, complete all as specified and as directed by the Engineer-in-Charge.
Supplying and laying of 3.5 core 300 sqmm PVC/ XLPE insulated PVC sheathed heavy duty, armoured electrical cables with Aluminium conductor for working voltage upto and including 1100volts ( conforms to IS:1554, Part-1) , suitable for earthed grade, complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 3.094 above, but 3.5 core 240sqmm.
All as per Item No. 3.094 above, but 3.5 core 50sqmm.
All as per Item No. 3.094 above, but 3.5 core 35sqmm.
All as per Item No. 3.094 above, but 3.5 core 25sqmm.
All as per Item No. 3.094 above, but 4 core 16sqmm.
All as per Item No. 3.094 above, but 4 core 10 sqmm.
Supplying and laying of 4 core 16 sqmm PVC/ XLPE insulated PVC sheathed heavy duty, armoured electrical cables with Copper conductor for working voltage upto and including 1100volts ( conforms to IS:1554, Part-1), complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 3.101 above, but 4 core 10 sqmm. stranded ( Copper)
All as per Item No. 3.101 above, but 4 core 6 sqmm. stranded ( Copper)
All as per Item No. 3.101 above, but 3 core 4 sqmm. stranded ( Copper)
All as per Item No. 3.101 above, but 3 core 2.5 sqmm. ( Copper Control cable)
All as per Item No. 3.101 above, but 3 core 1.5 sqmm. ( Copper Control cable)
Supplying and fixing 3.5 core 240sqmm size end termination with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade, complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 3.107 above, but 3.5 core 50sq. mm.
All as per Item No. 3.107 above, but 3.5 core 35sq. mm.
All as per Item No. 3.107 above, but 3.5 core 25sq. mm.
All as per Item No. 3.107 above, but 4 core 16sq. mm.
All as per Item No. 3.107 above, but 4 core 10sq. mm.
All as per Item No. 3.107 above, but 3/4 core 16sq. mm.( Copper)
All as per Item No. 3.107 above, but 3/4 core 4 - 10sq. mm.( Copper)
All as per Item No. 3.107 above, but 3 core 1.5sq. mm.( Copper Control cable)
All as per Item No. 3.107 above, but 3 core 2.5sq. mm.( Copper Control cable)
Supplying and installing 100mm width X 50mm depth X 1.6 mm thickness of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc., complete all as specified and as directed by the Engineer-in-Charge. (Powder coated shall be of Siemens Grey Colour- RAL 7032)
All as per Item No. 3.117 above, but size 150mm width X 50mm depth X 1.6 mm thickness
All as per Item No. 3.117 above, but size 200mm width X 50mm depth X 1.6 mm thickness
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required, complete all as specified and as directed by the Engineer-in-Charge.
Supply & laying 25x5mm GI strip at 0.5mt below ground as strip earth electrde including connection/terminatng with GI nut,bolt,spring,washer etc as required.)jointing shall be done by overlapping & with 2sets of brass nuts bolt&spring washer spaced at 50mm), complete all as specified and as directed by the Engineer-in-Charge.
SUB TOTAL OF SCHEDULE "A" Part - III
SCHEDULE "A" PART - IV [LIGHTNING PROTECTION]
Supply & installation of Air termination, single pointed aluminium rod 12mm dia and 300mm long as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge.
Supply & installation of Test point terminal block made of gun metal or phasphours bronze size 75X75X25mm drillied and screwed including 3 nos. 8mm dia 25mm long hex. Head screw as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge.
Supply & installation of Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground with porcelain insulator as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Earthing complete with galvanised steel pipe electrode, 40mm bore,medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing galvanised iron 32×6mm strip as eartlung lead or steel wire including adequate quantity of charcol dust & common salt as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge.
Supply and lay GI pipe light grade 50mm dia layed in trenches for protection of GI strip, complete all as specified and as directed by the Engineer-in-Charge.
SUB TOTAL OF SCHEDULE "A" Part - IV
SCHEDULE "A" PART - V [DG SET]
Supply, Installation, testing & commissioning of 500 KVA DG coupled to 500 KVA alternator as per detailed specifications, with canopy reducing the noise to 75 db at a distance of 1 meter as per specifications & latest CPCB -II norms, (b) Base frame and DG shall have radiator, (c) DG shall be suitable for paralleling, (d) Gerb or equivalent make antivibration pads, (e) Electronic governor with communication port, (f) Day tank/ base tank for fuel with level markings inside canopy, (g) All lockable doors having brass handles, (h) Front shall have perspex sheet to indicate fuel guage & ECP Panel along with one emergency push button out side canopy, (i) Fuel piping from internal tank shall be brought O/side canopy & connected for gravity feed to common external tank, (j) Suitable space heater for alternator, (k) Lub oil drain arrangement, (l) Canopy to have required size blower for cooling as well as air combustion. (Calculation for blower shall be submitted along with drawing), (m) Canopy temperature shall not rise beyond 70 degree C above ambient and necessary temperature gauges will be installed, (n) Suitable amended alternator cable box with sufficient space for flexible lads/ cores of 3 / 3.5C x 300 sq. mm armoured XLPE aluminium cables and also suitable arrangement for 3 nos. Cable exit with proper arrangement/ provision for mounting/ fixing double compression glands on alternator cable box,
Item No. 5.01(Contd) (o) Provision in the canopy for taking out silencer, control cables & power cables in proper manner in such a way that after commissioning no foreign material like water, insect, reptile can entre from these cut-outs, (p) Suitable self priming pump with engine (inbuilt by the manufacturer), (q) Provision in the canopy for taking out 3 runs XLPE AL armoured cables along with control cables. Cable box on top of alternator shall be modified to take out 3 nos. 3.5C aluminium armoured cables with proper arrangement/ provision for mounting/ fixing double compression glands on alternator cable box from bottom/ side, (r) Maintenance free batteries with leads & connectors complete with mounting arrangement & protection switchgears, (s) DG shall be completely filled with luboil & fuel required for commissioning and trial run for 2 hrs, including 10% overload for half an hour.
Supply, designing, fabrication and installation of exhaust pipe of suitable size and thickness of DG sets along with exhaust stack including two coats of red oxide and one coat afterward with high temperature resistance paint as per the approved colour / existing stack colour. Before fabricating, the contractor has to get the design approved from the Project Manager/consultant. The exhaust structure shall be suitable for 1 Nos. 500 KVA DG sets. Stack shall be installed along the wall & above terrace level as per standard norms, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour of MS ERW Pipe of 300mm bore minimum 4.85 mm thick with complete bends & flanges and all accessories, complete all as specified and as directed by the Engineer-in-Charge.
Supply and installation of 300 mm dia SS flexible bellows with matching flanges along with required hardware i.e. gasket, nut bolt, washer etc as required, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Insulation of above 300mm dia pipe with RBS wool of min 50mm. thickness 148 Kg/ m3 density and 24 SWG aluminium cladding inside & outside DG room complete. Insulation will be done in such a way that temperature surrounding it shall not exceed 5oC beyond ambient, complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation of 38/40 mm MS fuel pipe of suitable thickness between common existing HSD fuel tank to fuel tanks inside 500 KVA SDG inclusive all fitments / bends / accessories/ valves etc including level gauges, complete all as specified and as directed by the Engineer-in-Charge:
All as per Item No. 5.06 above, but 20mm fuel pipe
All as per Item No. 5.06 above, but 25mm fuel pipe
Supply, Erection, installation, testing & commissioning of 990 ltr. overhead raised buffertank M.S diesel tank manufactured with 2mm thick MS sheet complete with manholes cover, drain valve, marking along with M.S structure (bottom of tank at 0.6 meter high) with inbuilt flame proof level switches inside, complete all as specified and as directed by the Engineer-in-Charge.
SUB TOTAL OF SCHEDULE "A" Part - V
SCHEDULE "A" PART - VI [EOT CRANE]
Design, fabricate, supply, errect, test and commissioning of 40/5 Ton Capacity EOT crane pendant with push button and radio remote control system complete with span of 21.6 Mtrs (approx), long travel of 50.2 Mtr (approx) and lift hook 10 Mtr from floor level including supply, laying of crane track rail of suitable cross section on gantry girder with connected accessories like rope drum, steel wire rope, sheaves, pulleys, hydraulic thruster brake, single phase preventer, over load relay, SFU, air brake contactor, main hoist motor, micro hoist motor, cross travel motor, long travel motor, lifting hook, service platform, ladders, buffers, limit swtiches etc complete all as specified and directed by Engineer-in-Charge including the following :- (a) Design supply, install, test and commissioning DSL system with PVC shrouded copper bus bar for 3 phase and neutral including earth bus system all as specified suitable for 40/5 TON EOT Crane. (b) Supply of tools as per the list of OEM specifications. (c ) Supply of spares for two years operation and normal maintenance as per the list of OEM specifications. (d) Provision of LT power cable of suitable size from the panel board to crane. (e) Provision of additional push button system with interlocking wiring etc., complete as per OEM specification. (f) Main hoist speed - 3 Mtr/min (g) Main creep speed - 0.3 Mtr/min (g) long travel speed - 10 Mtr/min (j) Long creep speed - 1 Mtr/min (h) Cross travel speed - 10 Mtr/min (l) Cross creep speed - 1 Mtr/min
Item No. 6.01(Contd) NOTES:- (1) All the crane/hoist are including gantry rails of suitable size DSL system with PVC shrouded copper bus bar etc complete required as per site. (2) All micro speed will be 1/10 of main speed by all motions. (3) Audio visual alarm to provide to all motions, single phase preventer, over load relay, safety siren/over load alarm (4) All cranes & hoist shall confirm to IS 807 & IS 3177. (5) The bidder have to visit the site before quoting the tender please. (6) Provn of walk way with hand railing on both side wall (7) Contractor should be submitted of Technical specifications, Instruction Manual, Catalogue and spare parts maintenance manual, Maintenance manual, Material test certificates, mechanical GA Drawings, Factory inspection report and Material catalogue after errection of crane. (8) After erection of crane TRIAL and Final LOAD TEST to be done with of User department in presence of Engineer-in-change. (9) Safty platform to be provided to CT Crab unit for maintenance purpose. (10) Cabin to be provided for maintenance of DSL Bus bar. (11) Safe load indicator (SLI) ,Hoist gravity limit, Bridge lamp, Busbar indication lamp, Safty Alarm and hooter to be provided. (12) Tool Box to be provided after completion of work. (13) Drive should be seperate for Main hoist, Long travel and Cross travel in LT Panel. (14) After erection of crane Final paint to be done for finishing of crane.
Design, fabricate, supply, errect, test and commissioning of 10/2Ton Capacity EOT crane pendant with push button and radio remote control system complete with span of 21.6 Mtrs (approx), long travel of 50.2 Mtr (approx) and lift hook 10 Mtr from floor level including supply, laying of crane track rail of suitable cross section on gantry girder with connected accessories like rope drum, steel wire rope, sheaves, pulleys, hydraulic thruster brake, single phase preventer, over load relay, SFU, air brake contactor, main hoist motor, micro hoist motor, cross travel motor, long travel motor, lifting hook, service platform, ladders, buffers, limit swtiches etc complete all as specified and directed by Engineer-in-Charge including the following :- (a) Design supply, install, test and commissioning DSL system with PVC shrouded copper bus bar for 3 phase and neutral including earth bus system all as specified suitable for 10/2 TON EOT Crane. (b) Supply of tools as per the list of OEM specifications. (c ) Supply of spares for two years operation and normal maintenance as per the list of OEM specifications. (d) Provision of LT power cable of suitable size from the panel board to crane. (e) Provision of additional push button system with interlocking wiring etc., complete as per OEM specification. (f) Main hoist speed - 3 Mtr/min (g) Main creep speed - 0.3 Mtr/min (g) long travel speed - 10 Mtr/min (j) Long creep speed - 1 Mtr/min (h) Cross travel speed - 10 Mtr/min (l) Cross creep speed - 1 Mtr/min
Item No. 6.02(Contd) NOTES :- (1) All the crane/hoist are including gantry rails of suitable size DSL system with PVC shrouded copper bus bar etc complete required as per site. (2) All micro speed will be 1/10 of main speed by all motions. (3) Audio visual alarm to provide to all motions, single phase preventer, over load relay, safety siren/over load alarm (4) All cranes & hoist shall confirm to IS 807 & IS 3177. (5) The bidder have to visit the site before quoting the tender please. (6) Provn of walk way with hand railing on both side wall (7) Contractor should be submitted of Technical specifications, Instruction Manual, Catalogue and spare parts maintenance manual, Maintenance manual, Material test certificates, mechanical GA Drawings, Factory inspection report and Material catalogue after errection of crane. (8) After erection of crane TRIAL and Final LOAD TEST to be done with of User department in presence of Engineer-in-change. (9) Safty platform to be provided to CT Crab unit for maintenance purpose. (10) Cabin to be provided for maintenance of DSL Bus bar. (11) Safe load indicator (SLI) ,Hoist gravity limit, Bridge lamp, Busbar indication lamp, Safty Alarm and hooter to be provided. (12) Tool Box to be provided after completion of work. (13) Drive should be seperate for Main hoist, Long travel and Cross travel in LT Panel. (14) After erection of crane Final paint to be done for finishing of crane.
SUB TOTAL OF SCHEDULE "A" Part - VI
SCHEDULE "A" PART - VII [EXTERNAL WATER SUPPLY]
Supply, laying, jointing and testing 80mm bore GI tubing (IS:1289) medium grade with all fittings and fixing accessories such as Tees, elbows, bends, sockets, unions, plugs and sockets, short pieces connector and back nuts, deminishing pieces, cap plugs etc (ISI marked) laid in trenches,wall etc complete all as specified and directed.
All as per Item No. 7.01 above, but 50 mm bore of tube
All as per Item No. 7.01 above, but 40 mm bore of tube
All as per Item No. 7.01 above, but 25 mm bore of tube
Material and Labour for Gun Metal gate or globe valves suitable to 50mm bore, ISI marked (IS-778/84) pressure tested 1.5 mpa with iron wheel head, screwed both ends for iron pipe and fixed complete suitable for 50mm bore of pipe all as specified and directed.
All as per Item No. 7.05 above, but suitable to 40mm bore
All as per Item No. 7.05 above, but suitable to 25mm bore
Material and labour for Constructing masonry Chamber 90x90x100 cm (innerside dimension), in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 all as per TD drawing.
Supply and fixing ball brass valves, high pressure with polythene flot and flynut complete screwed for iron pipe and brass ferrule and fixed of 25 mm dia
Supplying, fixing and testing of packaged fixed skid mounted hydropneumatic system comprising of the following: Vertical, inline multistage centrifugal pumping set with stainless steel SS-304 stage casing and SS-304 impellers with stainless steel SS-316L shaft as per IEC standards and GJL250 cast iron suction & discharge casing, connected to TEFC ventilated induction motor of 2 pole, 2900rpm, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. Pressure vessel of non corrosive FRP composite construction lined with NSF and/or FDA listed material, like high density polyethylene with fully replaceable polyurethane. Air cell burst pressure of minimum of 5 times the vessel operating pressure and cycle tested for 2,50,000 cycles- 1 No. of capacity 100 Ltrs Control Panel with programmable logic controller (PLC) for cyclic operation of pumps. Pump working sequence should change after every operation. Contactor overload relays and MCBs should confirm to IEC 898 – 1995/ specifications. Blinking indications for pumps start, trip, low level trip, health supply should be provided in the panel along with the ammeter & voltmeter. Control panel should also consist of cooling fan. Pressure switches bellow type fitted with micro switch and having maximum pressure and differential scale should confirming BS-6134 standards and IP55 protection class.
Item No. 7.10(Contd) Stainless steel suction and delivery header, ball valve on each pump on suction delivery side, non return valves, Y strainer complete in all respect. Ball valves to be used should be Hot Pressed brass OT-58 with stainless steel ball and P.T.F.E seal and O-Ring. NRVs to be used should be with Springs and O-Ring arrangement. Complete set system to be mounted on a common base frame and shall follow following duty. For domestic water supply, 02 No.s (1 working + 1 stand by) Capacity : 450 LPM, Head : 30 m
Supply and fix Rotational moulded polyethylene water storage tanks of capacity 2000 Ltrs (cylindrical vertical with closed top), minimum three layered, hoisted and fixed in position , complete all as specified and as directed by the Engineer-in-Charge
Material and Labour for Valve pit internal dimension 450x450x500 mm brick masonary construction including all necessary excavation and earth work in any type of soil, complete as per TD drawings, complete all as specified and as directed by the Engineer-in-Charge.
SUB TOTAL OF SCHEDULE "A" Part - VII
SCHEDULE "A" PART - VIII [EXTERNAL ELECTRIC SUPPLY]
Material and labour for HT 11KV voltage , 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker Panel incomer cum outgoing as per latest IEC having rupturing capacity 350 MVA,overload andearth fault protection, ammeter, voltmeter and of rating upto 630 Amp including following accessories , complete all as specified and as directed by the Engineer-in-Charge (i) One (1) Nos. 11KV 630 Amps. 350MVA, 26kA for 1sec. Electrically/ manually operated draw out type vacuum circuit breaker complete with trip free spring charged closing mechanism, necessary auxiliary relays, control switches, emergency hand trip devices and mechanical ON / OFF indicator etc. (ii) One (1) Multifunction Meter showing all Electrical Paramater ie Volt, Ampere, kw, kVA, P.F., kWH etc (iii) One (1) digital type ammeter with 11kV Cast resin CTs for metering (100-50/5-5A, CL- 1, 15VA) with ASS and 2 Amp SP MCB. (iv) One (1) voltmeter (0-15KV) with VSS (v) One (1) Set of phase indication lamps with 2Amp SP MCB for protection (Red, Yellow and Blue). (vi) One (1) set of Red/ Green indicating lamp for close and open position. (vii) One (1) No. amber indicating lamp for auto trip. (viii) One (1) No. clear indicating lamp for trip circuit healthy. (ix) One (1) blue indicating lamp for spring charged. (x) One (1) strip heater to prevent absorption of moisture. (xi) One (1) set of 3 O/C + 1E/F (with High Set) Neumerical Relay with 3 Nos. 11kV Resin Cast CTs 100/50/5-5A, CL 10P10, 15VA.
Item No. 8.01(Contd) (xii) Master Trip Relay. (xiii) Trip circuit supervision relay (xiv) One (1) No. Potential Transformer 11KV/√3/110/√3 100VA burden (xv) One (1) set of 3Element 24V DC Aux. Relay with H/R flag for tripping of Transfomer Fault ie. OTI, WTI & Buchholz Tripping. (xvi) One (1) set of 3 Element 24V DC Aux. Relay with H/R flag for Alarm of HT line Fault ie. Earth fault, O/C, U/V & O/V with tripping. (xvii) One (1) set of 8 Stage 24V DC Annunciator with builtin test/Accept/ Reset Push Button along with 24V DC Hooter. (xviii) Master Trip Relay. (xix) 12 Window Annunciator (xx) Auxiliary switch/relay, master trip, anti pumping relay Trip circuit supervision relay and other control relays etc. as per requirements. (xxi) Power Pack : (xxii) One (1) Set 230V A.C, / 24V DC, Battery Backup, Power Pack to operate atleast 5Nos. Operation without AC Supply.
Material and Labour for HT 11KV voltage , 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker Panel incomer cum outgoing with extendable in future upto 3 VCBs with 1 incomer and 2 outgoing as per latest IEC having rupturing capacity 350 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 630 Amp, complete all as specified and as directed by the Engineer-in-Charge including following accessories:- (ii) One (1) Nos. 11KV 630 Amps. 350MVA, 18.6kA for 1sec. Electrically/ manually operated draw out type vacuum circuit breaker complete with trip free spring charged closing mechanism, necessary auxiliary relays, control switches, emergency hand trip devices and mechanical ON / OFF indicator etc. (iii) One (1) Multifunction Meter showing all Electrical Paramater ie Volt, Ampere, kw, kVA, P.F., kWH etc. (iv) One (1) digital type ammeter with 11kV Cast resin CTs for metering (50/5A, CL- 1, 15VA) with ASS and 2 Amp SP MCB. (v) One (1) voltmeter (0-15KV) with VSS. (vi) One (1) Set of phase indication lamps with 2Amp SP MCB for protection (Red, Yellow and Blue). (vii) One (1) set of Red/ Green indicating lamp for close and open position. (viii) One (1) No. amber indicating lamp for auto trip. (ix) One (1) No. clear indicating lamp for trip circuit healthy. (x) One (1) blue indicating lamp for spring charged. (xi) One (1) strip heater to prevent absorption of moisture. (xii) One (1) set of 3 O/C + 1E/F (with High Set) Neumerical Relay with 3 Nos. 11kV Resin Cast CTs 50/5A, CL 10P10, 15VA. (xiii) Master Trip Relay.
Item No. 8.02(Contd) (xiv) Trip circuit supervision relay (xv) One (1) No. Potential Transformer 11KV/√3/110/√3 100VA burden (xvi) One (1) set of 3Element 24V DC Aux. Relay with H/R flag for tripping of Transfomer Fault ie. OTI, WTI & Buchholz Tripping. (xvii) One (1) set of 8 Stage 24V DC Annunciator with builtin test/Accept/ Reset Push Button along with 24V DC Hooter. (xviii) Master Trip Relay. (xix) 12 Window Annunciator (xx) Auxiliary switch/relay, master trip, anti pumping relay Trip circuit supervision relay and other control relays etc. as per requirements. (xxi) Power Pack : (xxii) One (1) Set 230V A.C, / 24V DC, Battery Backup, Power Pack to operate atleast 5Nos. Operation without AC Supply.
Supply, installation, testing and commissioning of 1000 KVA 11KV/0.433KV KNAN 3phase 50Hz, Indoor Type, copper wound with OLTC (ON lod tap changer) step down transformer complete with all modern fittings as given in the specifications including all standard fittings and acessories , complete all as specified and as directed by the Engineer-in-Charge (i) As per IS 1180 Part - 3 Energy Efficiency Level-3 as per latest ammendment dated 4 March 2022 (ii) The transformers shall be installed in hot, humid tropical atmosphere. All equipment accessories and wiring shall be provided with tropical finish to prevent fungus growth. (iii) The transformers shall be OLTC Type & capable of continuous operation of rated output under the operating conditions of voltage and frequency variations as per statutory limits governed by relevant Indian Standard and Indian Electricity Rules, 1956 / IEC with latest amendments in force. (iv) Requirement: 11KV/433V OLTC Type with ON LOAD Tap Changer (OLTC), Tapping range +5% to -15% in steps of 1.25 % (HV side). (v) Voltage Ratio: No load voltage 11000/433volts within tolerance as stipulated in latest IS standard. (vi) Insulating material shall be of proven design. Class A Insulation (vii) Rating: The transformer shall have a continuous rating as specified at any of the specified tapping position and with the maximum temperature rise specified. (viii) Temperature Rise: The maximum temperature rise at the specified maximum continuous output shall not exceed 40°C / 45°C by thermometer of oil / winding above ambient temperature of 50°C." (ix) Transformer overloading as per IS Standard
Item No. 8.03(Contd) (x) Connections: H.V. Delta and L.V Star connected with neutral brought out on the secondary side for connection to earth; Vector group Dyn11 of IS: 1180 (xi) Each 11KV/433V Step down transformers shall be provided with the following fittings and accessories: (xii) Rating and terminal marking plate -1 (xiii) Lifting Lugs -4 (xiv) OLTC -1 (xv) RTCC-1 (xvi) AVR-1 (xvii) Earthing Terminals-2 (xviii) Uni-directional Flat Rollers -4 (xix) Radiators Fixed / Detachable - Adequate (xx) Explosion vent with Diaphragm -1 (xxi) Conservator with drain plug-1 (xxii) Oil filling hole with cap-2 (xxiii) Oil level indicator-2 (i) Magnetic oil level gauge - 01 No. (ii) Plain oil level gauge - 01 No. (xxiv) Dehydrating Silicagel Breather-1 (xxv) GOR for alarm and trip-1
Item No. 8.03(Contd) (xxvi) Terminal Arrangement HV-Cable Box (xxvii) Terminal Arrangement LV-Cable Box (xxviii) Separate Neutral Bushing -1 (xxix) Filter valve with blanking plate-1 (xxx) Drain cum filter valve with blanking plate-1 (xxxi) Air release device-1 (xxxii) WTI with alarm & trip-1 (xxxiii) OTI with alarm & trip-1 (xxxiv) Thermometer Pocket-2 (xxxv) Marshalling Box-1
Supply & fixing of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size, complete all as specified and as directed by the Engineer-in-Charge
Supply & fixing of Carbon dioxide (CO2) type fire extinguisher with suitable base pipe & horn (conforming to IS 2876 with cylinders fully charged of capacity 9.0 Kgm), complete all as specified and as directed by the Engineer-in-Charge
Supply & fixing of Carbon dioxide (CO2) type fire extinguisher with suitable base pipe & horn (conforming to IS 2876 with cylinders fully charged of capacity 4.5 Kgm), complete all as specified and as directed by the Engineer-in-Charge
Supply & fixing of G.I buckets of capacity paint and written with white paint Fire and mounted on M.S. angle iron bracket of sizes 50 mm x 50 mm x 6 mm thick and 500 mm long including grouting in wall etc. as required including filling with dry sand 9 ltr capacity, complete all as specified and as directed by the Engineer-in-Charge
Supply of First aid box as approved by St. John Ambulance Brigade/Indian Red Cross Conforming to IS:2217 - 1963, complete all as specified and as directed by the Engineer-in-Charge
Supply & fixing of Shock treatment chart at least in three languages duly mounted on a wooden frame with glass, complete all as specified and as directed by the Engineer-in-Charge
Supply of Elastomeric mat 2 mm thick of standard width to withstand 1.1KV dielectric strength as per IS 15652/2006, complete all as specified and as directed by the Engineer-in-Charge
Supply & installation of Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge
Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected by using copper 32x6mm strip as earthling lead to the earthing test point all as specified and indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge
Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthling lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 of SSR Part I to the earthing test point all as specified and indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge. Note for Item no. 8.11 to 8.13: Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.
Supply & Installation of Chemical Earthing with copper earth plate 90x60cmx5mm thick, 2.5 meters length, buried directly in the ground ( Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate is not less than 1.25 meters below ground level, connected with copper earth strip 32x6 as shown in plate no.2 the earthing test point all as specified and indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge.
Supply & installation of Earthing complete with copper earth plate electrode 60 × 60cm× 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected using 32×6mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge
Supply & laying of Earth continuity conductor or main earthing lead of size 65 x 6 mm GI strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. , complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No. 8.16 above, but 50 x 6 mm GI strip
All as per Item No. 8.16 above, but 32 x 6 mm GI strip
All as per Item No. 8.16 above, but 25 x 4 mm GI strip
All as per Item No. 8.16 above, but 4mm dia galvanised iron or steel wire
All as per Item No. 8.16 above, but copper strip of 50 x 6 mm
All as per Item No. 8.16 above, but copper strip of 32 x 6 mm
All as per Item No. 8.16 above, but 1 core 16 sqmm CU earth wire
Supplying, installation, testing & commissioning of 415V, 3 Phase, 50 Hz., 4 wire system, sheet steel clad, dust and vermin proof cubical and Indoor type floor mounted, free standing extendible type Main LT Panel compartmentalized design and fabricated out of 2 mm CRCA sheet steel complete with Aluminium Bus bars, Electrical interlocks as per the various status of all the equipments. Providing & Fixing of base plate / channel, P/F the following Switchgears, complete with earth Bus bar throughout the length of the panel, terminal arrangement for Cables incomings / Outgoings from Top / Bottom as per drawings and as approved by consultant / Engineer incharge, The incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement, detachable gland plates, adequate size cable alley, Sign writing, Painting, Earthing, Numbering, Danger plate etc. complete as required as per specifications and drawing attached. Necessary PLC for controlling the logic of operation with interlocking for breakers and auxiliary feeders with suitable capacity in built UPS, bettaries complete in all respect. Incomer: 1000KVA Transformer rating (i) 1 No. 1600 A, 415V, 50kA (Ics=Icu=Icw =50 KA for 1 second), 4 Pole, Electrical draw out type, Micro-processor based release (for over current, Earth fault and short circuit protections) A.C.B. with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required. each feeder shall have following: (ii) Digital flush type class-1.0 accuracy multifunction meter showing all parameters including V, A, PF, KVAR , KWH, Frequency / Harmonics etc. with 3 Nos. current transformers of 1600/5 ratio, 15 VA Class 1.0 metering.
Item No. 8.24(Contd) (iii) 6 nos NO/NC contacts for remote opening & closing. (iv) Red/Green/Amber ON/OFF/TRIP indicating lamps with 2A SP MCB backup protection. (v) 1 set of three phase indicating lamps along with 2A SP MCB backup protection. (vi) Spring charge& DC supply healthy indicating lamp with 2A SP MCB backup protection. (vii) Separate set of Class 5P10, 15VA CT of suitable capacity for protection/Capacitor Panel APFC reply (viii) Shunt trip coil. (ix) Motor wound spring closing mechanism. (x) Control MCB, control terminals& wiring as required. (xi) 7 mode surge suppression with suitable rating fuses & base complete as required. (xii) 40A TP MCCB for fixed type 15KVAR capacitor bank. (xiii) Restricted Earth fault relay with current transformers of 1600/5 ratio, 15 VA Class 5P 10 (xiv) Undervoltage, Overvoltage & phase reversal relay for persisted voltage of 105-180% & 20-95% of rated voltage. (xv) All outgoing feeders shall be provided with one set of three phase R,Y,B indicating lamps along with 2A SP MCB backup portection and 1 Set of ON/OFF/Trip indicating lamps .
Item No. 8.24(Contd) (c) Incomer: 500KVA DG set rating (i) 1 No. 800 A, 415V, 50kA (Ics=Icu=Icw =50 KA for 1 second), 4 Pole, Electrical draw out type, Micro-processor based release (for over current, Earth fault and short circuit protections) A.C.B. with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required. each feeder shall have following: (ii) Each DG incomer shall have annunciation for LLOP, HWT & oil temp (annunciator shall reset itself) O/C, E/F, engine should trip on LLOP, HWT, oil temp, O/V, O/F and breaker should trip on other faults, Initially U/V & U/F will be bye passed till oil pressure is picked up, motorised potentiometer for voltage raise & lower along with raise/ lower switches, suitable battery charger for 24V 360 AH (minimum capacity 25Amp), Indicating lights for neutral contactor ON, D.G. on mains, D.G. fails to start, Generator start /stop facility through push button from panel. 1 No. engine crancking relay,whenever D.G. stop through PB, load shall be disconnected first, complete AMF logic along with cranking relays to start the DG incase of power failure and DG stoping incase of power restoration and AMF shall be microprocessor based with indication for DG ON/OFF and load ON, 1 Set of starter for DG canopy blower, battery charger, starter with cyclic timer for lub oil priming pump, supply for space heater. (iii) Digital flush type class-1.0 accuracy multifunction meter showing all parameters including V, A, PF, KVAR , KWH, Frequency / Harmonics etc. with 3 Nos. current transformers of 800/5 ratio, 15 VA Class 1.0 metering. (iv) 6 nos NO/NC contacts for remote opening & closing. (v) Red/Green/Amber ON/OFF/TRIP indicating lamps with 2A SP MCB backup protection.
Item No. 8.24(Contd) (vi) 1 set of three phase indicating lamps along with 2A SP MCB backup protection. (vii) Spring charge& DC supply healthy indicating lamp with 2A SP MCB backup protection. (viii) Separate set of Class 5P10, 15VA CT of suitable capacity for protection/Capacitor Panel (ix) Shunt trip coil. (x) Motor wound spring closing mechanism. (xi) Control MCB, control terminals& wiring as required. (xii) Restricted Earth fault relay with 3 Nos. current transformers of 800/5 ratio, 15 VA Class 5P 10 (xiii) All outgoing feeders shall be provided with one set of three phase R,Y,B indicating lamps along with 2A SP MCB backup portection and 1 Set of ON/OFF/Trip indicating lamps . (d) Bus Coupler: (i) 1 No. 1250 A, 415V, 50kA (Ics=Icu=Icw =50 KA for 1 second), 4 Pole, Electrical draw out type, Micro-processor based release (for over current, Earth fault and short circuit protections) A.C.B. with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required. each feeder shall have following: (ii) 6 nos NO/NC contacts for remote opening & closing. (iii) Red/Green/Amber ON/OFF/TRIP indicating lamps with 2A SP MCB backup protection. (iv) Spring charge& DC supply healthy indicating lamp with 2A SP MCB backup protection. (v) Shunt trip coil.
Item No. 8.24(Contd) (vi) Motor wound spring closing mechanism. (vii) Control MCB, control terminals& wiring as required. (viii) All outgoing feeders shall be provided with one set of three phase R,Y,B indicating lamps along with 2A SP MCB backup portection and 1 Set of ON/OFF/Trip indicating lamps . (e) Incomer: 625/750KVA DG set rating (i) 1 No. 1250 A, 415V, 50kA (Ics=Icu=Icw =50 KA for 1 second), 4 Pole, Electrical draw out type, Micro-processor based release (for over current, Earth fault and short circuit protections) A.C.B. with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required. each feeder shall have following: (ii) Digital flush type class-1.0 accuracy multifunction meter showing all parameters including V, A, PF, KVAR , KWH, Frequency / Harmonics etc. with 3 Nos. current transformers of 800/5 ratio, 15 VA Class 1.0 metering. (iii) 6 nos NO/NC contacts for remote opening & closing. (iv) Red/Green/Amber ON/OFF/TRIP indicating lamps with 2A SP MCB backup protection. (v) 1 set of three phase indicating lamps along with 2A SP MCB backup protection. (vi) Spring charge& DC supply healthy indicating lamp with 2A SP MCB backup protection. (vii) Separate set of Class 5P10, 15VA CT of suitable capacity for protection/Capacitor Panel (viii) 24 V DC Shunt trip coil. (ix) Motor wound spring closing mechanism.
Item No. 8.24(Contd) (x) Control MCB, control terminals& wiring as required. (xi) Restricted Earth fault relay with 3 Nos. current transformers of 1250/5 ratio, 15 VA Class 5P 10 (xii) All outgoing feeders shall be provided with one set of three phase R,Y,B indicating lamps along with 2A SP MCB backup portection and 1 Set of ON/OFF/Trip indicating lamps. (f) Bus Bar-I (i) A set of TPN Aluminum bus bars rated for 1800A (after considering all necessary deratings) 3 phase 4wire, 50Hz. A minimum derating factor of 0.75 must be taken for calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere given in the BOQ The conductivity of bus bar shall not be less than 58% and earth bus size shall be 10% of phase bus bar. (50kA) (g) Bus Bars-II (i) A set of TPN Aluminum bus bars rated for 1400A (after considering all necessary deratings) 3 phase 4wire, 50Hz. A minimum derating factor of 0.75 must be taken for calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere given in the BOQ The conductivity of bus bar shall not be less than 58% and earth bus size shall be 10% of phase bus bar. (50kA) (h) Outgoings : (i) All outgoing shall have Ics = 50 KA (As per SLD) (ii) 1 Nos. TPN feeder having 1000A TPN MDO ACB, ON /OFF/TRIP indication, 1 no. digital MFM (showing all parameters) and matching cast resin CT's with control MCB.
Item No. 8.24(Contd) (iii) 1 Nos. TPN feeder having 1000A 4P MDO ACB, ON /OFF/TRIP indication, 1 no. digital MFM (showing all parameters) and matching cast resin CT's with control MCB. (iv) 1 Nos. TPN feeder having 800A 4P MDO ACB, ON /OFF/TRIP indication, 1 no. digital MFM (showing all parameters) and matching cast resin CT's with control MCB. (v) 2 Nos. TPN feeder having 160A TP MCCB with isolable neutral, ON /OFF indication, 1 no. digital MFM (showing all parameters) and matching cast resin CT's with control MCB. (vi) 6 Nos. TPN feeder having 100A TP MCCB with isolable neutral, ON /OFF indication, 1 no. digital MFM (showing all parameters) and matching cast resin CT's with control MCB. (vii) 2 Nos. TPN Spare feeder having 400A TP MCCB with isolable neutral, ON /OFF indication, 1 no. digital MFM (showing all parameters) and matching cast resin CT's with control MCB. (viii) 1 Nos. TPN Spare feeder having 320A TPN MCCB, ON /OFF indication, 1 no. digital MFM (showing all parameters) and matching cast resin CT's with control MCB. (ix) 1 Nos. TPN Spare feeder having 200A TP MCCB with isolable neutral, ON /OFFindication, 1 no. digital MFM (showing all parameters) and matching cast resin CT's with control MCB. (x) 1 Nos. TPN Spare feeder having 160A TP MCCB with isolable neutral, ON /OFF indication, 1 no. digital MFM (showing all parameters) and matching cast resin CT's with control MCB.
Item No. 8.24(Contd) (xi) 1 No. SPACE suitable for TPN feeder having 400A TP MCCB with isolable neutral & provision for MFM complete with suitable busbar links. Other items such as (i) 1 Lot of control wiring (ii) 1 Set of designation plates MAIN LT PANEL Described as above.
Design, Manufacturing, Supply, installation,Testing and commissioning of Smart Hybrid Active Filter to achieve Pf > 0.99 Lag and TDDi values within IEEE 519-2014 recommended limits. The degree of protection of enclosures system shall be IP30. The switching device of the active compensation system shall be IGBT based. The active compensation system specifications are mentioned below. The active compensation system should do the Pf correction as a 1st Priority and 2nd Priority as harmonics compensation (remaining capacity after Pf correction). Response time shall be 100 micro Sec or less. The passive part switching device shall be contactor based. The entire system should work in an integrated manner with a single controller, complete all as specified and as directed by the Engineer-in-Charge. Make: Inphase/ schnieder/ ABB Technical specification : Electrical Characteristics Connection method -3‐Ph-3‐Wire System Network Voltage - 415V Permissible Voltage Variation +/-10% Ampere Rating - 500A AHF IGBT Connection Topology -3 Level Topology System Frequency -50 Hz (+/- 5%) Equipment Efficiency - 98% of the equipment power typically Compensation Modes - Closed Loop Reaction time - 0.1 ms (Instantaneous) Response time - 1 ms Harmonics Compensation - Resource Delivery from 3rd to 61st Order Harmonics Compensation
Item No. 8.25(Contd) Controller Design - Rugged Design with Multiple I/Os IGBT Max Junction Temperature - 175 Degree Centigrade Note: for complete detail pl. refer technical specification attached with this doc. Capacitor Panel Specification Voltage Variation: +/-10% Rated Frequency: 50 Hz (+/- 5%) Capacitor Rated Voltage: 525V Capacitor Output Voltage: 440V Capacitor Unit Type: MPP Heavy Duty Capcaitor Switching Device: Contactor Switched (AC-3) Capacitor Panel KVAr - 450 KVAr @ 440V Step Size with KVAR rating - (4x 100KVAr + 1X50KVAr) Step protection Back-up Protection - Each step with MCCB protection Ambient Condition - Indoor 10°C to 50°C, 60% Relative humidity, non-condensing Reactor Rating: Detuned Series 14% reactor Aluminum wound with Class H insulation.
Item No. 8.26(Contd) OUTGOINGS: MCCB Ics-25kA & MCB as per specified (ii) 5 Nos. TPN feeder having 63A 4P MCB "C" curve, ON indication with MFM with all parameters & matching cast resin CT's & control MCB . (iii) 1 Nos. TPN feeder having 40A 4P MCB, ON indication with MFM with all parameters & matching cast resin CT's & control MCB. (iv) 1 Nos. SPN feeder having 63A DP MCB "C" curve, ON indication with MFM with all parameters & matching cast resin CT's & control MCB . Other items such as 1 Lot of control wiring 1 Set of designation plates
All as per item No. 8.26 above but with following accessories (FEEDER PILLER-1): INCOMING: (i) One number TPN incomer feeders comprising of 100A TP MCCB with isolable neutral and ON indication, BUSBAR: (i) One set of TPN, 'AL' bus bar rated 150 Amps (after considering necessary deratings of 75%) for phases and neutral for half capacity of phases. OUTGOINGS: MCB as per specified (i) 4 Nos. 25A TPN feeders each having one no. 25A TP MCB's with isolable neutral, contactor & 24 hour real timer for auto switching of load. (ii) 4 Nos. 40A SPN feeders each having one no. 40A DP MCB's "C-Curve. (iii) 1 Nos. 25A SPN feeders each having one no. 25A DP MCB's "C-Curve. Other items such as 1 Lot of control wiring 1 Set of designation plates Complete panel Described as above.
All as per item No. 8.26 above but with following accessories (FEEDER PILLER-2): INCOMING: (i) One number TPN incomer feeders comprising of 100A TPN MCCB with isolable neutral and ON indication, BUSBAR: (i) One set of TPN, 'AL' bus bar rated 150 Amps (after considering necessary deratings of 75%) for phases and neutral for half capacity of phases. OUTGOINGS: MCB as per specified (i) 4 Nos. 25A TPN feeders each having one no. 25A TPN MCB's with isolable neutral, contactor & 24 hour real timer for auto switching of load. (ii) 2 Nos. 63A TPN feeders each having one no. 63A 4P MCB's "C-Curve. (iii) 1 Nos. 40A TPN feeders each having one no. 40A 4P MCB's "C-Curve. (iv) 4 Nos. 40A SPN feeders each having one no. 40A DP MCB's "C-Curve. (v) 1 Nos. 25A SPN feeders each having one no. 25A DP MCB's "C-Curve. Other items such as 1 Lot of control wiring 1 Set of designation plates Complete panel Described as above.
Item No. 8.32(Contd) (ii) 2 Nos. 63 Amps TP feeder having one no. 63A TP MCCB & ON/ OFF indication. The starter shall use all for 415 VAC, 3 phase, 50 Hz, 3phase 4wire supply system. The panel shall have 1No. Star/Delta Starter feeder with single phase preventer and outgoing feeder to jockey pump motor (1 no. 10HP) with MCCB switch gears rating as per type II co-ordination alongwith 1no ammeter & 1no. matching cast resin CT including Start/Stop push bottons, toggle switch for `ON'/`TRIP' status of motor complete in all respect. (iii) 1 no. 32 Amps TP feeder having one no. fixing 32A TP MCB with ON/OFF indication. Providing & Fixing of AMF Auto Start panel with pressure switch for diesel engine (1 no. - 65HP) complete with all accessories, battery, battery charger, wiring & cabling including connection to diesel engine complete as required ready for working. Other items such as 1 Lot of control wiring 1 Set of designation plates.
Supplying, installation, testing & commissioning of 415V, 3 Phase, 50 Hz., 4 wire system, sheet steel clad, dust and vermin proof cubical and outdoor type floor mounted, free standing extendible type Isolator Panel compartmentalized design and fabricated out of 3.15 mm CRCA sheet steel complete with Aluminium Bus bars, Electrical interlocks as per the various status of all the equipments. Providing & Fixing of base plate / channel, P/F the following Switchgears, complete with earth Bus bar throughout the length of the panel, terminal arrangement for Cables incomings / Outgoings from Bottom only and as approved by consultant / Engineer incharge, the incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement, detachable gland plates, adequate size cable tray, Sign writing, Painting, Earthing, Numbering, Danger plate etc. complete as required as per specifications and drawing attached. (ii) 1 No. 1250 A 4Pole Isolator without any protection complete with suitable operatig handle, BUS bars links for suitable cable terminations & incoming & outgoing cable entries. 1 Lot of control wiring 1 Set of designation plates
Supply, laying, testing and commissioning of 3C x 4 sq. mm stranded copper armoured LT cables suitable for earthed system complete with end termination; Aluminium thimbles for aluminium conductor cables and copper thimbles for copper conductor cables of 1100 V grade extruded XLPE with insulated PVC inner sheath, unarmoured / GI wire/tape armoured (as specified below) and outer PVC sheathed cable of IS- 7098 standard of following sizes in trenches, cable racks or trays or pipes, including supply of GI clamps and screws and providing aluminum cable tags at every 20 metres and at both termination points, including unloading and transportation of cables at site, unpacking, complete with labour and material, complete all as specified and as directed by the Engineer-in-Charge
All as per Item No. 8.35 above, but 3C x 6 sq. mm stranded copper armoured cable.
All as per Item No. 8.35 above, but 3C x 10sq. mm stranded copper armoured cable.
All as per Item No. 8.35 above, but 4C x 16 sq. mm stranded aluminium armoured cable.
All as per Item No. 8.35 above, but 4C x 4 sq. mm stranded copper armoured cable.
All as per Item No. 8.35 above, but 4C x 6 sq. mm stranded copper armoured cable.
All as per Item No. 8.35 above, but 4C x 10 sq. mm stranded copper armoured cable.
All as per Item No. 8.35 above, but 4C x 16 sq. mm stranded copper armoured cable.
All as per Item No. 8.35 above, but 3.5C x 50 sq. mm stranded copper armoured cable.
All as per Item No. 8.35 above, but 3.5C x 70 sq. mm stranded copper armoured cable.
All as per Item No. 8.35 above, but 3.5C x 95 sq. mm stranded copper armoured cable.
All as per Item No. 8.35 above, but 3.5C x 120 sq. mm stranded aluminium armoured cable.
All as per Item No. 8.35 above, but 3.5C x 150 sq. mm stranded aluminium armoured cable.
All as per Item No. 8.35 above, but 3.5C x 240 sq. mm stranded aluminium armoured cable.
Supplying and laying in trenches or ducts or passing through the pipe, testing and commissioning of cable 3C x 240 sq.mm HT 11 KV grade XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric HT power cable, suitable for earthed system (heavy duty with standed aluminium conductor cables of IS- 7098 laid over MS supports in existing trenches, complete all as specified and as directed by the Engineer-in-Charge
All as per item No. 8.49 above but for 3C x 185 sq.mm 11 KV XLPE cable
Supply and fixing Cable joining kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185 sqmm, complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240sqmm to 300 sqmm, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240sqmm to 300 sqmm, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing Cable jointing kit for 11 KV grade cable for straight through termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240sqmm to 300 sqmm, complete all as specified and as directed by the Engineer-in-Charge.
Material and Labour for Boring holes of 300 mm dia up to 2 m deep in soil for under-reamed piles and getting out and disposal of spoil to a distance of n exc. 50 m, complete all as specified and as directed by the Engineer-in-Charge
Material and Labour for Boring holes of 300mm dia above 2 m deep in soil but not exceeding 5 m deep for under-reamed piles and getting out and disposal of spoil to a distance of n exc.50 m, complete all as specified and as directed by the Engineer-in-Charge
Material and Labour for Digging of Horizintal boring of size 200mm dia for laying of PVC insulated and PVC sheathed / XLPE power cable with supply & laying of 150mm HDPE PIPE /DWC/ HUME PIPE complete in all respect including removal & shifting of debris as required, complete all as specified and as directed by the Engineer-in-Charge
Supply & laying of 100mm HDPE PIPE , complete all as specified and as directed by the Engineer-in-Charge
Supply & laying of 150mm HDPE PIPE , complete all as specified and as directed by the Engineer-in-Charge
Supply & laying of 200mm HDPE PIPE , complete all as specified and as directed by the Engineer-in-Charge
Supply & laying of 300mm HDPE PIPE , complete all as specified and as directed by the Engineer-in-Charge
Supply and erect in true vertical position, Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-37 (9.50 metres long), including loop - in - loop - out box suitable for 3 Ph 4 wire cable termination with 6A MCB, complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing LED street light fittng 60Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection , complete all as specified and as directed by the Engineer-in-Charge. Cat Part No. ENDURAOMNIPLUSSL60WLED757SASYTOPC of make Havells or equivalent model of approved make.
Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm, complete all as specified and as directed by the Engineer-in-Charge.
Supplying and laying reinforced precast concrete cable cover, Class HV, Type 1, flat, size 300mmx l80mm x 40mm, complete all as specified and as directed by the Engineer-in-Charge.
SUB TOTAL OF SCHEDULE "A" Part - VIII
SCHEDULE "A" PART - IX [FIRE ALARM & FIRE FIGHTING SYSTEM]
Supply & installation of Detectors Complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination with base with self built intelligence as per IS:11360, Detectors shall comply with Detector housings shall be moulded in pure white self-extinguishing polycarbonate, V-O rated to UL94. Detectors will be unobtrusive when installed as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge
Supply, Installation, Testing & Commissioning of Beam Master detector with Transmitter and receiver (Add power supply units & Module) with a Beam range of 5-70m, 6 levels sensitivity, with Alarm & trouble response time from 20-30 sec, self compensation limit. In improper initial alighment and alignmet mode trouble conditions, with local alarm test/reset switch with remote test & reset switch capability including alarm trouble and alignment aids indication, suitable for -10°C to 55°C environment temperature with suitable mounting arrangement for hanging arrangement Complete in all respect as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge
Supply & installation of Addressable control module (UL listed) with normal operating voltage 15 to 32V DC, maximum current 6.5mA & tempearature range 0°C to 49°C. Face plate of control module is made of off-white heat-resistant plastic complete in all respect as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge
Supply & installation of Addressable monitor module (UL listed) with normal operating voltage 15 to 32V DC, maximum current 6.4mA, tempearature range 0°C to 49°C, Maximum IDC wiring resistance: 1,500 Ohms, Maximum IDC Voltage: 11 Volts, Maximum IDC Current: 240 μA & EOL resistance: 47K Ohms complete in all respect as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge
Supply & installation of Addressable manual call point resettable type, Each MCP installed on the loop shall have a unique address, set at the commissioning stage by means of a seven-segment DIL switch. The elapsed time between activation of the MCP and initiation of the sounders in an alarm condition via command from the fire alarm control panel shall not exceed three seconds complete in all respect as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge
Supply & installation of Addressable loop powered sounder strobe. Dual tone hooter shall be of electronic type and shall give discontinuous/intermittent audible alarm automatically when ever smoke detector or heat detector operates. Hooter shall be complete with magnetic coil ( sound coil ) and accessories, ready for mounting ( fixing ). The hooter shall also have facilities for speaker announcement. Hooter shall also have the capability for adjusting the sound output. Hooter casing shall be fabricated from 16 gauge MS sheet stove enameled to smooth finish. The line matching transformer shall be provided complete in all respect as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge
Supply & installation of Short circuit Isolators (UL listed) with normal operating voltage 15 to 32V DC(Peak) , standby current 450 µA & tempearature range 0°C to 49°C complete in all respect as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge
Supply & installation of Remote response indicators, Response Indicator shall be housed in a 16-gauge aluminium casing. It shall glow clearly incase the detector to which it is connected gives an alarm signal. The word "FIRE" shall be clearly written on the visible face of the box. It shall have two numbers of red LED to compensate for fusing of either LED complete in all respect as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge
Supply & Fixing of Stove enamelled, blank, 20 mm dia Rigid steel conduit, welded, conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends andfixing accessories such as couplers, locknuts, saddles, pipe hooks etc complete in all respect as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge
All as per Item no. 9.10 above but for 25mm Dia
Supply & installation of Networkable & Microprocessor based 160 ‐ characters LCD / Touch Screen LCD Display Network Repeator panel. The LCD shall Display all events / detectors, devices status of complete systems in the networked, The repeator shall be equipped with Mounting options etc. (UL Approved) complete in all respect as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge
Supplying & laying of cabling for fire detection and alarm system with 2 core annealed tinned copper conductor Fire Survival, 2 x 1.5 sq mm armoured cable complete in all respect as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge
Supplying & laying of 8 Core 1.5Sq MM wire from Main Fire Alarm Panel to Repeater Panel complete in all respect as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker, complete all as specified and as directed by the Engineer-in-Charge
Supplying, installation, testing & commissioning of 1.5/3/6W wall speaker, complete all as specified and as directed by the Engineer-in-Charge
Supplying, installation, testing & commissioning of digital audio amplifier 100Watt, 25V rms operating at 240 Volt AC Supply, complete all as specified and as directed by the Engineer-in-Charge
Supplying, installation, testing & commissioning of Voice command keypad 10 zone, with microphone assembly, complete all as specified and as directed by the Engineer-in-Charge
Supplying, installation, testing & commissioning of Speaker cable single pair 2 core x 1.0 sqmm IN EXISTING CONDUIT, complete all as specified and as directed by the Engineer-in-Charge
Supplying and fixing Hydrant valve single headed, complete all as specified and as directed by the Engineer-in-Charge
Supplying and Fixing First Aid Hose Reel 36 Meter long, complete all as specified and as directed by the Engineer-in-Charge
Supplying and fixing Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short, complete all as specified and as directed by the Engineer-in-Charge
Supplying and Fixing RRL hose type - A 15 mtr long, complete all as specified and as directed by the Engineer-in-Charge
Supplying and Fixing internal Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white internal, complete all as specified and as directed by the Engineer-in-Charge
Supplying and fixing Air vessel 300mm dia 2 m height, complete all as specified and as directed by the Engineer-in-Charge
Supplying, laying, fixing, testing and commissioning of 200 mm dia 6.0 mm thick ISI marked (IS:1239) MS ERW PIPE including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/slabs and making good the same etc., complete all as specified and as directed by the Engineer-in-Charge
All as per Item No. 9.26 above but 150 mm dia, 5.4 mm thick
All as per Item No. 9.26 above but 100 mm dia, 5.4 mm thick
All as per Item No. 9.26 above but 80 mm dia, 4.8 mm thick
All as per Item No. 9.26 above but 65 mm diA, 4.5 mm thick
All as per Item No. 9.26 above but 50 mm dia, 4.5 mm thick
All as per Item No. 9.26 above but 40 mm dia, 4.0 mm thick
All as per Item No. 9.26 above but 32 mm dia, 4.0 mm thick
All as per Item No. 9.26 above but 25 mm dia, 4.0 mm thick
Supplying and fixing Butterfly Valve suitable to 200mm dia pipe, complete all as specified and as directed by the Engineer-in-Charge
All as per Item No. 9.35 above but suitable to 150 mm dia pipe
All as per Item No. 9.35 above but suitable to 100 mm dia pipe
All as per Item No. 9.35 above but suitable to 80 mm dia pipe
Supplying and fixing Non Return Butterfly Valve suitable to 200 mm dia pipe, complete all as specified and as directed by the Engineer-in-Charge
All as per Item No. 9.39 above but suitable to 150 mm dia pipe
All as per Item No. 9.39 above but suitable to 80 mm dia pipe
Supplying and fixing Ball valve suitable to 25 mm dia pipe, complete all as specified and as directed by the Engineer-in-Charge
All as per Item No. 9.42 above but suitable to 50 mm dia pipe
Supplying and fixing Pressure gauge 4"dial 0-14 kgs rating, complete all as specified and as directed by the Engineer-in-Charge
Supplying and fixing 100mm dia Strainer for Suction, complete all as specified and as directed by the Engineer-in-Charge
All as per Item no. 9.45 above but for 150 mm dia.
Supplying, installation, testing & commissioning of Fire pump diesel engine driven horizontal end suction, entrifugal type confirming to IS- 12469 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 phase, 50 Hz AC supply, 2280 LPM at outlet head of 70 mts, complete all as specified and as directed by the Engineer-in-Charge.
Supplying, installation, testing & commissioning of Fire pump electrically driven horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 Phase. 50 Hz, 2280 LPM at outlet head of 70 mts, complete all as specified and as directed by the Engineer-in-Charge.
Supplying, installation, testing & commissioning of Jockey pump horizontal end suction centrifugal type Confirming to IS- 12469: 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with nonover loading power characteristics for frequent start / stop operations for 440 V , 3 phase, 50 Hz, 70 m head 180 LPM discharge, complete all as specified and as directed by the Engineer-in-Charge.
Supplying & fixing MS Class ‘C’ diesel engine exhaust pipe (including all fittings, clamps, steel support) of suitable dia for the engine. The pipe shall be provided with 12 mm thick supercera ceramic fibre rope, complete all as specified and as directed by the Engineer-in-Charge.
Supplying & fixing dial type (100 mm) pressure gauge 0-21 kgs rating, complete all as specified and as directed by the Engineer-in-Charge. Note: Contractor shall include in his rates for providing pressure switches, wiring, cabling from pressure switch to panel etc. complete as required to operate the system automatic/manual. Pump shall be protected against running dry.
Supplying, laying, jointing and testing in trenches 80mm dia MS class `C' (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, GI nuts, bolts and washers including excavation in all kind of soil, refilling, ramming, shoring, removing the excavated surplus material, providing adequate support to the pipe and making good the same complete as required. Rate shall include for dewatering necessary to execute the work. The pipe shall not be less than 1.0 m below ground level at any point. Pipes shall be embedded all around 150mm thick compacted sand and providing protection to embedded MS pipes and fittings by applying pyp kote primer (@ 100 gm/sqm) thereafter wrapping 4 mm thick pyp kote (AW 4 mm) protection coating by thermo fusion process. Overlap shall be maintained at 15 mm. The application process shall be strictly according to manufacturer’s specification, complete all as specified and as directed by the Engineer-in-Charge
All as per Item no. 9.52 above but for100 mm dia pipe.
All as per Item no. 9.52 above but for150 mm dia pipe.
Supplying & fixing Yard hydrant Post / Stand Post 80mm Dia GI / MS both flanged type 20 m height, complete all as specified and as directed by the Engineer-in-Charge
Supplying & fixing 4 way connection, complete all as specified and as directed by the Engineer-in-Charge
Supplying & fixing Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard, complete all as specified and as directed by the Engineer-in-Charge
Supplying & fixing GM fire brigade suction hose coupling (draw-out connection) with nut for female coupling as per IS standards complete with 100 mm dia GI suction pipe and 100 mm dia foot valve (to be connected to static tank). Provision of GI drop pipe and foot valve shall be made in all the fire water static storage tanks (2 Nos) (GI pipe to be paid separately through appropriate item while cost of foot valve to be included), complete all as specified and as directed by the Engineer-in-Charge
Supplying and fixing angle iron (40mmx40mmx5mm) door frame and S.S. sheet (2mm thick) cum glass shutter of size 2.1mtrx0.9mtr(N.S.) with 25mmx25mmx3mm angle frame all around and stiffened in between i/c hinges, handle, locking arrangement, painting with approved synthetic enamel paint i/c sign writing on glass at internal hydrant including providing & fixing S.S. sheet 2mm thick on remaining portion above door to close opening i/c painting etc. as required. Glass shall be 6 mm thick, complete all as specified and as directed by the Engineer-in-Charge Notes : (i)The cabinet shall be suitable to accommodate 2 nos. or 4 nos 15mtr long Hose pipe & 2 Nos branch pipe nozzle. It shall be mounted on raised Brick platform complete as required. (Cost shall be inclusive of providing break glass box containing key for the cabinet along with hammer). (iii) PORTABLE CHEMICAL FIRE EXTINGUISHERS
Supply and fixing of ISI marked (IS:2878) Fire Extinguisher, with provision of wall bracket (fixed with anchor fastner), Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket, complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing of ABC (Powder Type) Fire Extinguisher 6 Kg, with provision of wall bracket (fixed with anchor fastner), In HP Mild Steel Cylinders, ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and confoming to IS:1349-1993, complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing of CO2 type fire extinguishers with provision of wall bracket (fixed with anchor fastner), consisting of welded M.S. cylindrical body automatic modular CO2 type extinguisher actuated through a sprinkler head mounted on The extinguisher body finished externally with red enamel with trolly mounted complete with internal charge, complete all as specified and as directed by the Engineer-in-Charge. (Capacity 22.5 Kg.)
Supply and fixing Clean Agent Modular (ceiling mounted) Type Capacity 5 Kg CE certified Fire Extinguisher filled with HFC 236FAClean Agent Gas, complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing of 15 mm dia. sprinkler head with standard response Quartzoid Bulb operate at 57 degree C complete with all accessories as required and as per enclosed specification (UL Listed) Upright/Pendent type in chrome finish (Standard Coverage) , complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing brass quartzoid sprinklers (UL, FM approved) of 15 mm dia size, suitable for sustaining the seat & water hammer effect. The type & temperature rating shall be as follows Sidewell extended coverage (57 deg.C) sprinkler quick response type as per specifications, complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing Sprinkler flexible type 1.0 m, complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing Sprinkler flexible type 1.5 m, complete all as specified and as directed by the Engineer-in-Charge
Supply, installation, testing and commissioning of Flow switch of 80mm dia, complete all as specified and as directed by the Engineer-in-Charge
All as per Item no. 9.68 above but for 100 mm dia.
Supplying and fixing Air Cushion tank with relief valve 200mm, complete all as specified and as directed by the Engineer-in-Charge
Supplying and fixing 150 mm dia reinforced neoprene rubber vibration eliminators/expansion joints (to provide relief from stresses at pipe flanges) suitable for upto 20 kg/cm2 pressure, complete all as specified and as directed by the Engineer-in-Charge
All as per Item no. 9.71 above but for 100 mm dia.
Supplying and fixing of ICV / Alarm gong (Intermittent hydraulic alarm with alarm gong and water motor Alarm)150mm, complete all as specified and as directed by the Engineer-in-Charge
Supplying and ffixing of 25mm dia gunmetal air release valve with all fittings and forged ball valve on header complete as required and as per enclosed specifications, complete all as specified and as directed by the Engineer-in-Charge
Supplying and fixing Sluice Valve of 150mm dia, complete all as specified and as directed by the Engineer-in-Charge
SUB TOTAL OF SCHEDULE "A" Part - IX
SHELL REFRACTORIES and INSULATIONS
anjaliinfratech
B DURGA REDDY INFRASTRUCTURES PRIVATE LIMITED
CH.VEERARAGHAVULU CONSTRUCTION PVT LTD
RKEC Projects Limited
B D Raizada Projects Pvt Ltd
Indus Projects Private Limited
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid