Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | As L1₹21.6 LAccepted-AOC | As L1 | Accepted-AOC L1 | |
| 2 | As L2Rejected-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | As L2 | Rejected-Finance As L2 | |
| 3 | As L3Rejected-Finance 620 DIAMOND HARBOUR ROAD BEHALA INDUSTRIAL ESTATE PLOT NO F A KOLKATA 34 | KOLKATA | WEST BENGAL | As L3 | Rejected-Finance As L3 |
Tender Value
₹27.9 L
EMD Value
₹55,870
Closing Date
11 Jul 2018, 9:00 amClosed
Executive Engineer PWD BDN ELEC DIVN
Room no 1081st fl purta bhawan salt lake kolkata
Electrical works in relation to shifting of office premises of the Dept of FPI and H WB mayukh Bidhannagar Kol 91 to Benfish Tower SecV Salt lake City Kol 91 SITC of Air Conditioning System
2018_WBPWD_177865_1
WBPWD/EE/BED/16/e-IT of 2018_19
Open Tender
ELECTRICAL WORKS M/R
Item Rate
40 days
Mayukh Bhavan
Please refer Tender documents.
4 documents required · 4 mandatory
₹55,870
Yes
29 Sept 2021
22 Jun 2018
13 Jul 2018
27 Jun 2018
11 Jul 2018
27 Jun 2018
Amount
Supply of VRF / VRV Outdoor Unit Supply of Air cooled VRF top discharge type Outdoor Unit each comprising of variable speed inverter controlled scroll, air cooled condensor with protective coated fins, mounting frame, micro processor panel and other standard accessories as per specification.The unit shall be suitable for operation with R-410A refrigerant and to maintain the room temperature at 24 degree Centigrade and Humidity level as per latest standard of NBC. Minimum COP of the ODUs at 50% load & at 40 degree centigrade ambient condition should be 4.5. and there should be no capacity deration upto 40 degree Centigrade Bidders have to upload factory tested and certified data sheet in support of the confirmation of COP along with the model no in the folder “confirmation of compliance of Technical Specifications by the Bidder” under technical cover, failing which the bid may be rejected (Make: Mitsubishi/Blue Star/ Hitachi/ Toshiba/ Carrier/LG/Daikin) i) 24 HP- consists of 2 / 3 Nos SCROLL variable speed INVERTER Compressor.
VRF/VRV INDOOR UNIT. 4-WAY CASSETTE TYPE INDOOR WITH CORDLESS REMOTE. (i) SITC of 4-Way Cassette Type Indoor Unit With Cordless Remote Control including drain pump as required- Capacity - 2.8 TR, rated cooling capacity not less than 33600 BTU/Hr, Maximum Sound Pressure level 38 dB (A), the system should have atleast 3 fan speed (Make same as outdoor unit).
Do-----Do------Capacity - 1.7 TR, rated cooling capacity not less than 20400 BTU/Hr, Maximum Sound Pressure level 36 dB (A), The system should have atleast 3 fan speed (Make same as outdoor unit).
Do-----Do------Capacity - 1.5 TR, rated cooling capacity not less than 18000 BTU/Hr, Maximum Sound Pressure level 36 dB (A), The system should have atleast 3 fan speed (Make same as outdoor unit).
Do-----Do------Capacity - 1.3 TR, rated cooling capacity not less than 15600 BTU/Hr, Maximum Sound Pressure level 36 dB (A), The system should have atleast 3 fan speed (Make same as outdoor unit).
High wall type indoor unit with cordless remote. SITC of Variable Refrigerant Flow High wall split units comprising of copper coil section,filter section.The unit shall be complete with all standard accessories including cordless remote of capacity (Make same as outdoor unit) i) 2 TR, rated cooling capacity not less than 24000 BTU/H
SITC of Variable Refrigerant Flow High wall split units comprising of copper coil section,filter section.The unit shall be complete with all standard accessories including cordless remote of capacity (Make same as outdoor unit) i) 1.5 TR, rated cooling capacity not less than 18000 BTU/Hr
SITC of Variable Refrigerant Flow High wall split units comprising of copper coil section,filter section.The unit shall be complete with all standard accessories including cordless remote of capacity (Make same as outdoor unit) i) 1 TR, rated cooling capacity not less than 12000 BTU/Hr
SITC of Variable Refrigerant Flow High wall split units comprising of copper coil section,filter section.The unit shall be complete with all standard accessories including cordless remote of capacity (Make same as outdoor unit) i) 0.8 TR, rated cooling capacity not less than 9600 BTU/Hr
Y-Joint / Refnet. Supply and fixing of Y-Joint / Refnet Joint of required sizes.
Supply, fabrication , delivery and Installation of MS STRUCTURAL WORK as required to make the outdoor units ready and complete for installation and functioning as per direction of EIC and approval of drawing -for 24 HP outdoor units.
Supplying & laying of 2C/3C Shielded 'Copper' Control Cable. Control cable between the indoor units and the outdoor units.
CONDENSATE DRAIN PIPE. Condensate Drain line shall be with following size heavy duty high wall thickness PVC pipes & fittings. 32mm Dia.
REFRIGERANT PIPE. Refrigerant piping with (19, 13mm thick) nitrile rubber tube insulation. Referigerant pipes sizes shall be as below. Dia 38.1 mm with 19mm thick nitrile rubber
Do-----Do------ Dia 34.9 mm with 19mm thick nitrile rubber
Do-----Do------ Dia 31.75 mm with 19mm thick nitrile rubber
Do-----Do------ Dia 28.6 mm with 19mm thick nitrile rubber
Do-----Do------ Dia 25.4 mm with 19mm thick nitrile rubber
Do-----Do------ Dia 22.2 mm with 19mm thick nitrile rubber
Do-----Do------ Dia 19.05 mm with 19mm thick nitrile rubber
Do-----Do------ Dia 15.88 mm with 19mm thick nitrile rubber
Do-----Do------ Dia 12.7 mm with 19mm thick nitrile rubber
Do-----Do------ Dia 9.53 mm with 13mm thick nitrile rubber
Do-----Do------ Dia 6.35 mm with 13mm thick nitrile rubber
Installation, Testing & Commissioning of 24 HP outdoor unit with connected indoor units including cost of R410 A refrigerant complete VRF system. N.B.: (i) The Agency must procure the materials from the Manufacturer / OEM or from their authorized. Sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. (ii) Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work / submission of bill. (iii) If any refurbished material is supplied and installed, penal action will be taken as per existing rules.
L.W.C. must be quoted manually @1% on the total quoted value else the total quoted rate shall be treated incl. LWC as per rule. N.B. Rate should be quoted inclusive of GST.
BLUE STAR LIMITED
WEATHER MAKERS INDIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .