Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.2 LAccepted-AOC INDEX NO E 53 CWE BHUJ OPP SHRI HALARI BHANUSHALI WADI OUTSIDE KHAMBHALIYA GATE NR PAVAN CHAKKI JAMNAGAR 361005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹47.2 L+₹96,277.04 (2.08%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹47.5 L+₹1.2 L (2.56%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹49.8 L+₹3.6 L (7.73%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹52.3 L+₹6.0 L (13.1%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹44.0 L
EMD Value
₹87,980
Closing Date
21 Jul 2025, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar - 361 150
Special Repairs to B/R services and E/M fittings and fixtures at Power House/ Substation Room, Building No. P-410 (at Army Lines) under GE (I) Navy Jamnagar
2025_MES_701960_4
8837/VAL/E8
Open Tender
Miscellaneous Works
Item Rate
150 days
GE (I) Navy Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹87,980
Yes
4 Aug 2025
2 Jul 2025
23 Jul 2025
2 Jul 2025
21 Jul 2025
9 Jul 2025
Amount
Taking down cement plaster of any description on PCC/stone surface/brick surfaces including raking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Demolition of brickwork/PCC block or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for in this Schedule and removal of entire debris as ordered outside MoD land complete all as specified & as directed.
Dismantling of wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), stacking serviceable tiles at site and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Taking down chowkat or frame with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
Taking down chowkat or frame with shutters (including fittings & fixtures) area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
M&L for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops, coved fillets, padding over roof and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
M&L for reinforced cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in foundation including rafts, footings, foundation beams, plinth beams, base of columns etc., basement slabs, under-reamed piles and mass concrete including necessary formwork complete all as specified and as directed. Note: Reinforcement shall be measured and paid for separately.
Supply only Integral Water Proofing Compound (ISI Marked).
M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:4, complete all as specified & as directed.
M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified and as directed.
S&F Second class hard wood kiln seasoned, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed in position complete all as specified and as directed.
S&F factory made 35 mm thick second class hard wood plain framed panelled door shutter (any number of panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12mm thick veneered particle boards with commercial veneering on both face the size of rail and style as per IS - 1003 (Part I) kiln seasoned and chemically pressure treated and fixed to chowkats complete all as specified and as directed.
S&F 150 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed complete all as specified & as directed.
S&F butt hinges of size 100mm medium weight, cold rolled mild steel (ISI marked) complete all as specified and as directed.
S&F 150 mm size extruded aluminium alloy handle (ISI Marked), cast type, anodised and fixed complete all as specified & as directed.
S&F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S&F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples along with wooden beads complete all as specified and as directed.
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framed signed boards, walk ways, railings, framework of water tanks and similar work, framed and hung as gates including pintle hinges, stops, hand-made sliding bolts, etc including welding conforming to Fe.290 (Gde E-165), complete all as specified & as directed.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
M&L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment, including necessary welding etc. conforming to Fe-410-W (Gde E-250) quality `A’, complete all as specified and as directed.
S&F steel rolling shutters, 1.25mm thickness of laths, push pull or manual type, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, including dismantling & taking down the existing unserviceable rolling shutter, complete all as specified and as directed.
S&F aluminium powder coated (minimum thickness of powder coating 50 micron) frames for doors, windows and ventilators with one or more rebates including joining cleat for fixing, powder coated aluminium snap on beading, neoprene gasket etc. complete all as specified and as directed.
S&F aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutter, side hung type without sash bar, aluminium section weighting 0.55 kg/m including necessary jointing cleats, louvers, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos.), suitable handle (2 Nos.) etc. complete all as specified and as directed. Note: Glass/Wire mesh shall be measured and paid for seperately.
S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-Charge.
M&L for cutting out cracks to 'V' section in existing roofs or terrace cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified & as directed.
Material and labour for complete removal of existing water proofing treatment of any description or any other type of treatment over roof slab, parapets, chimney stacks, etc including cement plaster/PCC over RCC roof and cleaning the surface with wire brushes and washing with water, removing of insolvent materials and removing & depositing the debris, rubbish, etc outside MoD land, brushing neat cement slurry @ 3 Kg of cement per Sqm over the cleaned surface and provide 15mm thick screed bed/bedding layer/plaster in CM 1:3 mixed with integral Water Proofing Compound (WPC) as per manufacturer's instructions and finishing the surface even & smooth without using extra cement while the cement slurry is still green on RCC roof/parapet, provide oil bound bituminous primer @ 0.30 Kg/Sqm after bedding layer/plaster is cured with water for 7 days & completely dried, provide minimum 4mm thick APP based modified polymeric water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyester matt fabric weighing not less than 160 gms/Sqm with over laps 100 mm longitudinal direction (side laps) and 150 mm on the transverse direction (end laps) by thermo-fused torch flame application method as per detailed procedure as directed and finally finishing the top surface with one finishing coat of bituminous aluminium paint complete all as specified and as directed. Notes: (i) WPC shall be measured & paid for separately as ‘Supply only’. (ii) The work shall be carried out only through manufacturer or their authorised applicator and contractor shall submit a written guarantee of the manufacturer/authorised applicator for the effectiveness of WPT for 10 years from the date of completion of contract. (iii) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (iv) The net area of water proofing treatment shall be measured without any extra allowance for laps.
M&L for average 25mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in roof padding, floor, levelling course, etc by maintaining gradient/ undulation, finished even & smooth without using extra cement complete all as specified and as directed.
M&L for machine cut mirror polished Kota stone slab 20 to 25mm thick laid in floors etc over & including screed bed or bedding layer of 20mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed. Note : Quoted rate shall deemed to be inclusive of cement screed bed/bedding layer.
M&L for 18 to 20 mm thick granite (Jet Black) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, wash basin counter and the like, set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. Note : Quoted rate shall deemed to be inclusive of cement screed bed/bedding layer.
M&L for rounding to edges of stone slabs (one edge), 18 to 20mm thick stone as in steps, cooking platform and other similar situations, including machine polishing to edge to give high gloss finish etc., complete all as specified and as directed.
M&L for 75 mm thick plain cement conctere 1:3:6, type C1 (using 20 mm graded crushed stone aggregate) as in plinth protection, hard standing, etc, finished the surface even and smooth without using extra cement, complete all as specified & as directed. Note : Plinth protection shall be of width as directed and shall be laid with an outward slope of 1:40 in alternative bays not exceeding 2.5 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic filling comprising 1 part of heated bitumen Blown grade any penetration and 3 parts of sand (all by weight). Quoted rate of this item shall deemed to include this provision.
M&L for 75mm thick PCC 1:4:8, type D2 (using 40 mm graded crushed stone aggregate) as in sub-floors, sub-bases, floors and pavings, etc finished fair and even complete all as specified & as directed.
M&L for 100 mm thick PCC 1:2:4, type B2 (using 40 mm graded crushed stone aggregate) as in sub-floors, sub-bases, floors and pavings, etc finished fair and even complete all as specified & as directed.
M&L for glazed ceramic coloured tiles, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e. 600mm x 300mm / 450mm x 300mm as directed by Engineer-in-Charge), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick back coat in CM 1:4 complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got approved from GE before incorporation in the work.
M&L for factory made M-35 grade, 60 mm thick machine pressed, rubber moulded precast cement concrete interlocking paver blocks of shape and size as directed with grey cement and pigment confirming to IS: 15658-2006 (ISI marked), laid over and including 50 mm thick compacted sand cushion complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of 50 mm thick compacted sand cushioning. (ii) Shape of paver blocks shall be as approved by the GE.
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls mixed with WPC mixed @ minimum 2% by weight of cement or as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid for separately as 'Supply only'.
M&L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces in ceiling finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered / unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.
M&L for preparation of old surfaces of ceilings including scraping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc by hand held sander / long handle sander including cornices, pilasters etc (Plastered or unplastered surfaces) and applying two coats of white wash complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint complete all as specified & as directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick layer of white cement based wall care putty complete all as specified & as directed.
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces of wall and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick white cement based wall care putty on walls complete all as specified & as directed.
M&L for preparing newly plastered surface of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer's instructions complete all as specified and as directed.
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, rubbing down, stopping of distempered & Jet pressure washing and painted surface of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer's instructions complete all as specified and as directed.
S&F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads or fixed to aluminium sections exceeding 0.5 Sqm in each pane complete all as specified & as directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of 1st quality synthetic enamel paint of approved tint complete all as specified & as directed.
Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new sunk type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 and applying suitable matching painting as required shall deemed to be included in quoted rate of this item.
All as per serial item No. 57 here-in-before but for one 3 pin 5/6 Amp modular switch socket on same board with other switches.
All as per serial item No. 57 here-in-before but for one 3 pin 5/6 Amp modular switch socket on independent board.
All as per serial item No. 57 here-in-before but for one 16 Amp and 6 Amp (3 pin) combined, modular switch socket on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
S&F in repairs modular switch, single pole, one way, 6 Amp, 1 module with all accessories complete all as directed.
S&F in repairs modular switch, single pole, one way, 16 Amp, 1 module with all accessories complete all as directed.
S&F in repairs modular socket 6 Amp, 2/3 pin combined, 2 module with all accessories complete all as directed.
S&F in repairs modular socket multipurpose 6 / 16 Amp - 2/3 pin combined, 2 module with all accessories complete all as directed.
S&F in repairs ceiling rose surface bakelite White/ Ivory/ Urea finish 50mm dia three terminals including PVC square mounting block & electric wiring connection complete all as specified and as directed.
S&F in repairs clear white 20 Watt wall mounted 4 ft LED batten type decorative light fitting, minimum CCT 5700K, 230 Volts, 50 Hz, extruded aluminium housing & polycarbonate diffuser, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.
Taking down existing street/ security light fitting of any type & fixed in any position and S&F new 45 Watt LED street/ security light fitting, High Efficiency, minimum IP 65 protection, CCT - 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, powder coated pressure die cast aluminium housing, top opening with separate driver compartment and clear PMMA/polycarbonate/toughened glass heat resistant cover, fixed on walls or steel/concrete pole at any height including making connection from ceiling rose/ Junction Box to light fitting with and including three core 1.5 Sqmm cable multistranded copper conductor PVC insulated & PVC sheathed, 1100 V grade of required length fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion, fixed on wall/ pole on existing bracket including nut bolts & washers, complete all as specified and as directed.
Supply, assembling, hanging, fixing & testing Ceiling Fan of size 1200 mm sweep with BEE 5 star rated, with brushless direct current (BLDC) motor, single phase, AC supply, 230 Volt, with & including down rod, canopies, three number blades, hook, rubber reel, safety pins, nuts, bolts, washers, cable connector and making connection with PVC insulated & sheathed 1.5 Sqmm three core flexible copper multistranded conductor cable (ISI marked) from ceiling rose to connector of ceiling fan including marking of SM / MES number with thick synthetic enamel paint of approved tint including taking down existing old ceiling fan and depositing to MES store yard complete all as specified and as directed. Make: Bajaj Model No. ENERGOS 28 1200 MM GLOSSY WHITE CF (Without Remote) or equivalent in makes mentioned in Appendix 'B' here-in-after. Notes :- (i) The font, style & place of writing SM/ MES number with synthetic enamel paint on ceiling fan shall be as directed by the Engineer-in-Charge and cost thereof shall deemed to be included in quoted rates. (ii) Old Ceiling Fan shall be deposited to Store Yard of AGE E/M (N) Jamnagar.
S&F in repair modular step type fan regulator 120 W, 2 module, AC, 230V, complete all as specified and as directed.
S&F 450mm sweep, metal body, exhaust fan, AC, single phase, 230/240 V, copper winding motor, with louver shutter and connecting with & including three core copper conductor flexible cord of 1.5 Sqmm cross sectional area of required length from ceiling rose to the connector block of the exhaust fan including taking down existing old exhaust fan and depositing to MES store yard with & including cutting, opening of required size hole (Square/ Round) through RR masonry/ brick walls for fixing exhaust fan and making good disturbed surfaces of wall with CM 1:4 and painting with two coats of existing colour to match the wall complete all as directed by Engineer-in-Charge. Note : Old Exhaust Fan shall be deposited to Store Yard of AGE E/M (N) Jamnagar.
S&F 300mm sweep, metal body, exhaust fan, AC, single phase, 230/240 V, copper winding motor, with louver shutter and connecting with & including three core copper conductor flexible cord of 1.5 Sqmm cross sectional area of required length from ceiling rose to the connector block of the exhaust fan including taking down existing old exhaust fan and depositing to MES store yard with & including cutting, opening of required size hole (Square/ Round) through RR masonry/ brick walls for fixing exhaust fan and making good disturbed surfaces of wall with CM 1:4 and painting with two coats of existing colour to match the wall complete all as directed by Engineer-in-Charge. Note : Old Exhaust Fan shall be deposited to Store Yard of AGE E/M (N) Jamnagar.
S&F in repairs Distribution Board (DB) sheet metal enclosure, SPN, 8 way with 100 Amps rated bus bar, double door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
S&F in repairs MCB SPN 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as specified and as directed.
S&F in repairs MCB SP 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as specified and as directed.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
M&L for filling approved dry river sand for cushioning and cover for protection of under ground electric cable in trenches 8 cm before laying cable and 15 cm deep over the cable and punning to 18 cm total thickness complete all as specified and as directed. Notes :- (i) Approved dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
Taking down carefully old existing LT PCC Cable Cover of Class LV of any type & size complete all as specified & as directed.
Laying only LT PCC cable covers of any type & size for protection of UG LT electric cables in trenches, obtained serviceable from serial item No. 79 here-in-above, complete all as specified & as directed.
Supply and laying un-reinforced precast concrete cable cover, Class LV, Type-1, Flat, size 250mm x 150mm x 40mm for protection of underground electric cable in trenches complete all as specified and as directed.
Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 95 sqmm 3½ Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed. Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.
All as per serial item No. 82 here-in-above, but cross-sectional area 50 Sqmm 3½ Core.
All as per serial item No. 82 here-in-above, but cross-sectional area 35 Sqmm 3½ Core.
All as per serial item No. 82 here-in-above, but cross-sectional area 10 Sqmm 4 Core.
M&L for cutting of existing PCC floor / hardstanding / Interlocking tiles path / WBM road with soling & premix carpet of any description for removing / laying UG Cables/ pipe line, depth of cutting not exceeding 90cm and width 45cm and filling the trench of road i.e. excluding top 20cm with existing aggregate obtained from cutting, watered and properly rammed to satisfaction of EIC and finally provide with & including 20 cm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate to entire width of trench & finally match the top surface to road & disposal of debris to a distance not exceeding 250 metre and depositing where directed including re-setting of interlocking tiles/ Paver block (where required) complete all as directed.
M&L for Galvanized iron tubing, 100mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of HT/LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of HT/LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.
S&F Danger notice plate of 25x20cm size, 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour for HT 11000 Volts and fixed with suitable MS clamps made out of flat iron 25x3mm, bolts and nuts of approved size, fixed in repairs, complete all as specified & as directed.
Disconnecting, dismantling & taking down old unserviceable Panel Box of any size & capacity including all fixtures/accessories and Supply, installing, commissioning and testing factory made and tested (CPRI approved manufacturer) new outdoor type LT Timer Switch Panel Box cubical type of suitable size (minimum size 720mm x 870mm x 350mm) to accommodate the following accessories, 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, made out of 3.15 mm thick MS CRCA sheet (outer body, doors, etc), inside partitions & cover made out of 2mm thick MS CRCA sheet, with modular hinges, powder coated inside & outside with 7 tanks process in approved shade, protection class IP-55 with coloured insulation sleeve, rubber gasket, insulators, outdoor type, totally enclosed, weather, dust and vermin proof as per IS, Front & Rear opening with double door shutters having suitable aldrop bolt locking arrangement, with insulators, including internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size as directed with proper ferrule & cable glands including connecting incoming and outgoing cables, including danger notice plate, necessary PCC 1:3:6 type C1 in foundation and frame made out of 65 x 65 x 6mm angle iron grouted at minimum 45cm above ground level and 30cm below ground level, comprising & including the following accessories complete all as specified and as directed :- (a) MCCB 63 Amp, 4 Pole, 25 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type - 01 No. as incoming. description of item contd....
Description of serial item No. 90 contd… Notes : (i) Vertical height of legs of LT panel base frame shall be not less than 45 cm from top of nearest road level / PCC floor finish. Legs shall be grouted in ground minimum 30cm in PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate). (ii) The contractor shall produce and get the detailed (GD) drawings of LT Panel approved from GE through Engineer-in-Charge before fabrication and placing the order to the approved manufacturer. (iii) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (iv) Cost of internal wiring, MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with aldrop bolt and any minor addition/alteration where required at site (the decision of GE shall be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
Taking down existing post top lantern of any description and S&F new 45W, IP 65 decorative outdoor post top lighting fixture with powder coated pressure die cast aluminium housing and translucent diffuser. The fitting shall have LED with Lens and PCB. The minimum lumen output of the system should be greater than 4000 lumens. The fittings shall have minimum surge protection 5 kV and fitting shall be sealed with a non-ageing silicone gasket, fixed as per manufacturer’s instructions and making necessary electrical connections with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and testing on completion complete all as directed. Make : Bajaj 'BGCTN 45W LED WW' or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs Junction box made from SMC/FRP sheet readymade of size 200x150x100 mm having 100 A capacity including RYB and neutral with aluminium busbar with 4 way connector fixed to pole/wall with MS clamp made out of MS flat iron 25x5 mm with suitable nut, bolts, etc and necessary painting to MS clamp with two coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified & as directed.
Dismantling and taking down existing damaged/broken PCC Pole and S&F new 6 mtr height hot dip galvanized steel pole hexagonal/ octagonal cross sections grade S355JO of dimensions top dia 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate dimensions 200x200x12 mm, foundation bolt size 4 Nos x 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projected bolt length 100 mm, anchor plate thickness 3 mm with inbuilt compartment for mounting switch box, earthing etc covered with hinged door confirming to IS:2629 / BS EN ISO 1461 alongwith connections with & including MCB SP 6 Amp, 240 V, 10 kA, 'C' Curve (1 No.) & Connector (RYB&N) - 63 A Cap (01 No.) complete all as specified and as directed. Make of Pole: Bajaj Cat No. BOP-6030 (BOPH-6030) or equivalent in makes mentioned in Appendix 'B' here-in-after. Note: Earth work and PCC foundation shall be measured & paid for separately.
Taking down existing street light fitting of any description and S&F new 90 Watt LED street light fitting, High Efficiency, minimum IP 65 protection, CCT - 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, powder coated pressure die cast aluminium housing, top opening with separate driver compartment and clear PMMA/polycarbonate/toughened glass heat resistant cover, fixing to existing bracket including nut bolts, connected with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and electrically connected to the existing system and testing on completion complete all as directed.
Taking down existing flood light fitting of any description and Supply, installation, commissioning & testing 150 Watt LED Flood Light fitting, Luminaire Efficacy ≥ 110 lm/W, Correlated Colour Temperature (CCT) 5665K ± 355K, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, suitable for ambient temperature from (-)10°C to 50°C, Ingress protection of IP-66 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, 50 Hz, Power factor ≥ 0.95, Total Harmonic Distortion (THD) ≤ 10%, Built-in Surge Protection not less than 4 KV, External Surge Protection not less than 10 KV, double phase protection, no load, open circuit and short circuit protection, powder coated pressure die cast aluminium housing, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting, complete all as specified and as directed.
M&L in repair for street light bracket made from MS tubing in required size & shape at site, cut to length, bend to shape required and suitable for existing street light pole and fixing the bracket to pole with MS flat and nuts and bolts and finally painting the exposed steel surface with two coats of first quality synthetic enamel paint of approved tint over a coat of zinc chromate primer complete all as directed. Notes :- (i) Size, section and shape of MS pipe shall be as directed. (ii) Quoted rate shall deemed to be inclusive of painting. Weight of paint shall not be considered for payment purpose and quoted rate shall deemed to be included this aspect.
S&F in repairs 2.50 Sqmm 3 core PVC insulated, PVC Sheathed, multistranded copper conductor flexible cable of 1100 Volt grade (ISI marked) drawn through existing conduit pipe/ inside GI Pole from DB, Junction Box, etc to fitting with suitable lugs etc complete all as specified & as directed.
Disconnecting/ Taking out the existing transformer of the capacity 315 kVA from site for rationalisation/ repairing and transporting to workshop for servicing and repairing including loading, unloading and handling to carry out the necessary repairs and refixing the same after & including checking of all parts for repair/ replacement, repairing, installation, testing and commissioning at its original/ new location, decanting the transformer oil, etc, for smooth functioning, complete all as directed by Engineer-in-Charge. Notes :- (i) Necessary spare parts required replacement shall be replaced only after prior inspection & approval of Engineer-in-Charge and replacement shall be measured & paid for separately under relevant items of this Schedule. (ii) Unit rate quoted by the tenderer shall be deemed to include for minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding. (iii) All T&P & transportation shall be arranged by contractor and rates for the same shall deemed to be included in rate quoted.
Replacement of HT 11 KV bushing assembly with brass terminal, neoprene rubber gasket and washers etc complete with accessories for transformer of capacity 315 KVA.
Replacement of LT bushing assembly with brass terminal, neoprene rubber gasket and washers etc complete with accessories for transformer of capacity 315 KVA.
Replacement of Breather assembly complete including silica gel for transformer of capacity 315 KVA complete.
Replacement of radiator for transformer of capacity 315 KVA complete as per existing type & size.
Replacement of Oil glass for transformer of capacity 315 KVA complete as per existing type & size.
Rewinding of coils all as per its original specifications by new copper conductor and with HT/ LT necessary insulation materials in transformer of capacity 315 KVA.
Supply and filling new Transformer oil up to conservator level marking as per IS-335 having dielectric strength not less than 40 kV at 2.5mm gap complete all as specified and as directed. Make : Electrol, Power Oil, Indian Oil, Savita or equivalent as approved by GE.
Replacement of Silica Gel blue in crystal in existing transformer breathers for transformer of capacity 315 KVA.
M&L for preparation of external surfaces of distribution transformer of capacity 315 KVA including cleaning and removing oil spots from the body and painting with one coat of synthetic enamel paint (first quality) of approved tint with gun sprayer including marking of SM/MES No etc. on transformer with synthetic enamel paint (white) complete all as specified and as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
S&F in repairs 10mm thick chequered type insulating electrical rubber mat of size 4 x 8 ft (ISI Marked) complete all as specified & as directed.
M&L for Navy Blue LED sign board of size 5ft x 2.5ft with white Alphabets/ Letters, out door type, totally enclosed with locking arrangement, 3mm thick acrylic sheet, iron frame angle of size 45x45x5mm with minimum 4ft height from ground level and 1ft in depth grouted in PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) for sub-station/ plant with LED lights as directed (minimum 06 Nos of 10W LED light) and internal wiring complete with electrical connection from nearest street light pole/ panel including testing after completion with & including all standard accessories as per standard trade practice including two coats of synthetic enamel painting of approved tint over a coat of zinc chrome primer after preparation of steel surfaces of MS frame work complete all as directed by Engineer-in-Charge. Note: Quoted rate shall deemed to be inclusive of PCC, LED light and electrical connections. Letters/matter/logo/sign etc for sign board shall be given by the Engineer-in-Charge as per location of sign board. The lettering font & style, lightning work, etc shall be as directed by Engineer-in-Charge.
M&L for Air termination, single pointed aluminium rod 12mm dia and 300mm long fix to aluminium strip, nut, bolts and washers including taking down existing air termination complete all as specified & as directed.
M&L for aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including taking out existing aluminium strip complete all as specified & as directed.
S&F in repairs Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screws, enclosed in suitable PVC box, complete all as specified & as directed.
M&L for precast PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in bed blocks, anchorage blocks, foundation blocks, kneelers, apex stones, bed plates, cover slabs, mangers, shelves and similar articles with plain faces including placing in position over roof etc and set in CM (1:4) complete all as specified & as directed.
S&F in repairs porcelain insulator of overall minimum size 72mm x 32mm x 34mm (single pole bus bar support insulator) suitable for fixing aluminium/GI strip roof/down conductors, fixed in PCC blocks/walls/pole/pipe with two Nos hexagonal head GI screws 40mm long, one No. hexagonal head GI bolt 30mm long & 5-6mm dia with one No. square shaped GI washer of size 25x25mm & 0.6-0.8mm thickness & one No. GI nut for fixing/running the roof/down conductors, conforming to the sample kept in GE’s office, complete all as specified & as directed. Note : Cost of screws, bolt, washer & nut is included in quoted rates.
M&L for Galvanized iron tubing, 32mm bore, light grade, ISI marked, with & including all fittings and fixed to walls / ceilings or laid in floors, fixed in repair, complete all as specified & as directed.
Supply, fixing, commissioning and testing of HT CTPT unit of having Potential Transfer ratio (PT) 11000/ 110 Volt and Current Transfer ratio (CT) 75/ 5 Amp of class - 0.2 Sec including fixing on angle iron bracket on two pole structure with proper HT connection complete all as specified & as directed. Notes:- (i) Any type of T&P required to mount CTPT unit on two pole structure are inclusive in quoted rate of item. (ii) Angle iron frame shall be measured and paid for separately under relevant item of this schedule.
Supply, fix, commissioning and testing of HTCT energy electric Meter of 11 kV/√3/110V, 3-phase, 3-wire, 3-phase 4-wire, CT-5A, Class - 0.2 Sec, 50 Hz as per IS-14697, IS-15959, ingress protection IP 51 with & including SMC box of suitable size for mounting HT meter on two pole structure or as per site requirement and Test Terminal Blocks (TTB) (as per site requirement small/ big) including connection with suitable wiring/ Cable for HT electric meter to CTPT unit and other connected accessories, complete all as specified & as directed. Make of Meter :- Secure Premier 300 Meter or equivalent in makes mentioned in Appendix 'B' here-in-after. Make of SMC Box :- Sintex or equivalent in makes mentioned in Appendix 'B' here-in-after. Notes:- SMC box, TTB, connection with wiring/ Cable for HT electric meter to CTPT unit and other connected accessories are inclusive in above item quoted rate, no separate payment will be made.
M&L for Mild steel angle cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections & MS bars conforming to Grade E-165 (Fe 290) including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated/ directed with & including one coat of red oxide zinc chrome primer, one under coat of aluminium paint and one finishing coat of aluminium paint, fixed in repairs, complete all as specified & as directed. Notes :- (i) Size, section and shape of steel sections shall be as directed. (ii) Weight of paint shall not be considered for payment purpose and quoted rate shall deemed to be included this aspect.
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected using galvanized iron earth lead wire 4 mm dia upto 7.5mtr as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, charcoal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point including testing on completion complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / transformer / GOD / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing.
M&L for Earthing with & including copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including copper strip 20 x 3.15mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / transformer / GOD / equipment body / test point with two Nos nuts bolts or welding with steel structure, Copper earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing of any type.
M&L for galvanised iron strip 32 x 6mm earth continuity conductor or main earthing lead buried in ground / fixed on wall with suitable porcelain insulators including taking out existing GI strip complete all as specified and as directed.
S&F in repair copper strip 20mm x 3.15mm complete with saddles and fixing screws for fitting the strip or fixing with & including suitable porcelain insulators, complete all as specified & as directed.
Disconnecting the single/ double stage centrifugal pumping set, 75 HP (any make), separating from suction, delivery pipeline, electrical connection etc. dismantling the same including transporting to civil workshop for overhauling, repairing and replacing the unserviceable spare parts such as gland, packing, bearing bush, washer etc and installing, commissioning with proper alignment, making connection suction and delivery side with necessary new packing material, nut bolt etc. & testing for smooth functioning, complete all as specified and as directed. Notes : (i) The spare parts required to be replaced shall be measured and paid for separately as “Supply only” under the relevant items here-in-after. (ii) Unit rate quoted by the tenderer shall be deemed to include for minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding. (iii) All spare parts shall be fixed in the pumps & motors only after prior inspection & approval of Engineer-in-Charge. (iv) All T&P & transportation shall be arranged by contractor and rates for the same shall deemed to be included in rate quoted.
Supply only following new spare parts for single/ double stage centrifugal pumping set 75 HP, as per existing type of existing make/ used by OEM or equivalent make as approved by GE :-
Cast Iron impeller with key
Pump Neck ring brass
Pump Gun metal bush
Pump shaft made of EN9 steel
Pump Ball bearing No. 6207
Pump Ball bearing No. 6307
Steel bush with nut for pump shaft
Pump ball bearing housing
Rubber 'O' ring
Coupling for pumping set, pin and bush type with coupling bolt and key complete in all respect duly machined grooved for key & key way.
Cast Iron gland flange with stud
Spider star rubber coupling with alignment of pump and motor.
Mechanical seal for 75 HP Single/ double stage centrifugal pump set as per existing size
BLANK
BLANK
BLANK
BLANK
M&L for painting to pump & motor set of capacity 75 HP including MS channels, foundations, suction and delivery pipes up to 5m length from pump sets including cleaning the outer surfaces of any description, in any position, applying one coat of 1st quality synthetic enamel paint with proper colour codes and writing SM No. and MES No. etc., complete all as specified and as directed.
S&F electrical induction motor terminal connection plate (six terminal) made of heavy duty hylem sheets with copper alloy nuts, bolts and washers as per existing size / shape for 40 to 75 HP motor including taking down unserviceable terminal plate complete all as directed.
S&F in repair brass air release cock for pump set as per existing size and sample complete all as directed.
Disconnecting the electric connections, taking out the existing submersible pump set of capacity 10 to 15 HP from bore well by using proper chain pulley, tripod, etc, transporting to work shop, dismantling the submersible pump set, cleaning, descaling and re-assembling after repair/ replacement of spare parts including taking out pipe, cable etc. and lowering, fixing at the same/ new location, commissioning & testing for smooth functioning, complete all as directed. Notes : (i) The spare parts required to be replaced shall be measured and paid for separately as “Supply only” under the relevant items here-in-after. (ii) Unit rate quoted by the tenderer shall be deemed to include for minor spares/extras. The decision of Accepting Officer regarding minor spares/extras shall be final, conclusive and binding. (iii) All spare parts shall be fixed in the pumps & motors only after prior inspection & approval of Engineer-in-Charge. (iv) All T&P & transportation shall be arranged by contractor and rates for the same shall deemed to be included in rate quoted.
Supply only following new spare parts for submersible pump and motor of capacity 10 to 15 HP as per existing type of existing make/ used by OEM or equivalent make as approved by GE :-
CI stage casing
SS sand guard
SS sleeves at staging
SS impellers
Neck ring brass
Key for impeller
SS stud with nuts of size 3/8" X 2" for stage casing
Bush gun metal at intermediate section
SS Sleeve at intermediate section
CI thrust bearing
M&L for machining, turning, grinding & polishing of shaft of 10 to 15 HP submersible pump and motor complete all as directed.
Supply, fixing and lowering into borewell 6 Sqmm, 3 core, 1100 V grade, ISI marked, flat/ round submersible multistranded copper conductor PVC insulated and PVC sheathed cable for connection of submersible pupmsets with water proof jointing material, including dismantling & taking out old unserviceable cable, complete all as specified and as directed.
S&F in repair 50 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/sqcm with all fittings, for lowering of submersible pump set including stainless steel nipple both end of pipe connected as per required size, complete all as specified & as directed.
Disconnecting, dismantling & taking down old unserviceable LT Panel Box of any size & capacity including all fixtures/accessories and Supply, installing, commissioning and testing factory made and tested (CPRI approved manufacturer) new indoor type, LT Panel Box cubical type of suitable size (minimum size 1600 x 1525 x 450mm) to accommodate the following accessories, 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, made out of 2mm thick MS CRCA sheet (outer body, doors, etc), inside partitions & cover made out of 2mm thick MS CRCA sheet with modular hinges, powder coated inside & outside with 7 tanks process in approved shade, protection class IP-55 with coloured insulation sleeve, rubber gasket, insulators, indoor type, totally enclosed, weather, dust and vermin proof as per IS, front opening with double door shutters having suitable aldrop bolt locking arrangement, including internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size as directed with proper ferrule & cable glands including connecting incoming and outgoing cables, including danger notice plate, Feeder Name plate, necessary PCC 1:3:6 type C1 in foundation and frame made out of 65 x 65 x 6mm angle iron grouted at minimum 30cm above ground/floor level and 30cm below ground/floor level, comprising & including the following accessories complete all as specified and as directed :- description of item contd....
Description of serial item No. 139 contd… (a) MCCB 400 Amp, 4 Pole, 36 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type - 01 No. as incoming. (b) MCCB 125 Amp, 4 Pole, 25 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type - 01 No. as outgoing. (for 1st floor panel) (c) MCCB 63 Amp, 4 Pole, 25 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type - 01 No. as outgoing. (for 20 HP blower starter) (d) MCCB 100 Amp, 4 Pole, 25 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type - 02 Nos. as outgoing. (for 40 HP pump starter) (e) MCB TPN 32 Amp, 415 V, 50 Hz, AC supply, 10 kA, 'C' Curve - 02 Nos. as outgoing. (for bldg load) (f) 40 HP Fully automatic star delta starter, 3 phase - 02 Nos. (g) 20 HP Fully automatic star delta starter, 3 phase - 01 No. (h) Multifunction Meter with CT/ PT for each starter and main incoming - 04 Nos. (j) Indicator Set RYB, “LED” type (set of three) for each starter and main incoming - 04 Set (k) Aluminium Bus bar minimum 600 Amp with R/Y/B coloured for three Phases and 300 Amp for Neutral Black colour insulation sleeves - 01 Set description of item contd....
Description of serial item No. 139 contd… Notes : (i) Vertical height of legs of LT panel base frame shall be not less than 30 cm from top of nearest road level / PCC floor finish. Legs shall be grouted in ground minimum 30cm in PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate). (ii) The contractor shall produce and get the detailed (GD) drawings of LT Panel approved from GE through Engineer-in-Charge before fabrication and placing the order to the approved manufacturer. (iii) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (iv) Cost of internal wiring, MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with aldrop bolt and any minor addition/alteration where required at site (the decision of GE shall be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
Disconnecting, dismantling & taking down old unserviceable LT Panel Box of any size & capacity including all fixtures/accessories and Supply, installing, commissioning and testing factory made and tested (CPRI approved manufacturer) new indoor type, LT Panel Box cubical type of suitable size (minimum size 1750 x 1025 x 350mm) to accommodate the following accessories, 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, made out of 2mm thick MS CRCA sheet (outer body, doors, etc), inside partitions & cover made out of 2mm thick MS CRCA sheet with modular hinges, powder coated inside & outside with 7 tanks process in approved shade, protection class IP-55 with coloured insulation sleeve, rubber gasket, insulators, indoor type, totally enclosed, weather, dust and vermin proof as per IS, front opening with double door shutters having suitable aldrop bolt locking arrangement, including internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size as directed with proper ferrule & cable glands including connecting incoming and outgoing cables, including danger notice plate, Feeder Name plate, necessary PCC 1:3:6 type C1 in foundation and frame made out of 65 x 65 x 6mm angle iron grouted at minimum 45cm above ground/floor level, comprising & including the following accessories complete all as specified and as directed :- description of item contd....
Description of serial item No. 140 contd… (a) MCCB 100 Amp, 4 Pole, 25 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type - 01 No. as incoming. (b) MCCB 63 Amp, 3 Pole, 16 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type - 01 No. as outgoing. (for Bridge Panel) (c) MCB TPN 32 Amp, 10 kA, ‘C’ Curve, 415 Volt grade, AC, 50 Hz - 01 No (for bldg load) (d) 3 HP DOL starter - 06 Nos. (e) MCB TP 10 Amp, 10 kA, ‘C’ Curve, 415 Volt grade, AC, 50 Hz - 06 Nos. (for DOL starter) (f) Multifunction Meter with CT/ PT for main incoming - 01 No. (g) Ampere Meter for each starter - 06 Nos. (h) Indicator Set RYB, “LED” type (set of three) for each starter and main incoming - 07 Set (j) Aluminium Bus bar minimum 150 Amp with R/Y/B coloured for three Phases and 100 Amp for Neutral Black colour insulation sleeves - 01 Set description of item contd....
Description of serial item No. 140 contd… Notes : (i) Vertical height of legs of LT panel base frame shall be not less than 45 cm from top of nearest road level / PCC floor finish. Legs shall be grouted in PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate). (ii) The contractor shall produce and get the detailed (GD) drawings of LT Panel approved from GE through Engineer-in-Charge before fabrication and placing the order to the approved manufacturer. (iii) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (iv) Cost of internal wiring, MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with aldrop bolt and any minor addition/alteration where required at site (the decision of GE shall be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
Disconnecting, dismantling & taking down old unserviceable LT Panel Box of any size & capacity including all fixtures/accessories and Supply, installing, commissioning and testing factory made and tested (CPRI approved manufacturer) new outdoor type, LT Panel Box cubical type of suitable size (minimum size 1000 x 1000 x 400mm) to accommodate the following accessories, 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, made out of 3.15mm thick MS CRCA sheet (outer body, doors, etc), inside partitions & cover made out of 2mm thick MS CRCA sheet with modular hinges, powder coated inside & outside with 7 tanks process in approved shade, protection class IP-55 with coloured insulation sleeve, rubber gasket, insulators, outdoor type, totally enclosed, weather, dust and vermin proof as per IS, front opening with double door shutter having suitable aldrop bolt locking arrangement, including internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size as directed with proper ferrule & cable glands including connecting incoming and outgoing cables, including necessary danger notice plate, Feeder pillar name plate, necessary PCC 1:3:6 type C1 in foundation and frame made out of 65 x 65 x 6mm angle iron fixed at minimum 20cm above ground/floor level, comprising & including the following accessories complete all as specified and as directed :- description of item contd....
Description of serial item No. 141 contd… (a) MCCB 63 Amp, 3 Pole, 16 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type - 01 No. as incoming. (b) 5 HP DOL starter - 04 Nos. (c) MCB TP 16 Amp, 10 kA, ‘C’ Curve, 415 Volt grade, AC, 50 Hz - 04 Nos (for DOL starters). (d) Multifunction Meter for main incoming - 01 No. (e) Ampere meter for each starter - 04 Nos. (f) Indicator Set RYB, “LED” type (set of three) for each starter and main incoming - 05 Set (g) Aluminium Bus bar minimum 150 Amp with R/Y/B coloured for three Phases and 100 Amp for Neutral Black colour insulation sleeves - 01 Set description of item contd....
Description of serial item No. 141 contd… Notes : (i) Vertical height of legs of LT panel base frame shall be not less than 20 cm from top of nearest road level / PCC floor finish. (ii) The contractor shall produce and get the detailed (GD) drawings of LT Panel approved from GE through Engineer-in-Charge before fabrication and placing the order to the approved manufacturer. (iii) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (iv) Cost of internal wiring, MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with aldrop bolt and any minor addition/alteration where required at site (the decision of GE shall be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
Disconnecting, dismantling & taking down old unserviceable LT Panel Box of any size & capacity including all fixtures/accessories and Supply, installing, commissioning and testing factory made and tested (CPRI approved manufacturer) new indoor type, wall mounted, LT Panel Box cubical type of suitable size (minimum size 1550 x 1225 x 350mm) to accommodate the following accessories, 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, made out of 2mm thick MS CRCA sheet (outer body, doors, etc), inside partitions & cover made out of 2mm thick MS CRCA sheet with modular hinges, powder coated inside & outside with 7 tanks process in approved shade, protection class IP-55 with coloured insulation sleeve, rubber gasket, insulators, indoor type, totally enclosed, weather, dust and vermin proof as per IS, front opening with double door shutters having suitable aldrop bolt locking arrangement, including internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size as directed with proper ferrule & cable glands including connecting incoming and outgoing cables, including danger notice plate, Feeder Name plate, necessary fixing to Wall as directed, comprising & including the following accessories complete all as specified and as directed :- description of item contd....
Description of serial item No. 142 contd… (a) MCCB 100 Amp, 4 Pole, 36 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type - 01 No. as incoming. (b) MCB SPN 32 Amp, 10 kA, ‘C’ Curve, 240 Volt grade, AC, 50 Hz - 02 No (for bldg and spare) (c) MCB TP 32 Amp, 10 kA, ‘C’ Curve, 415 Volt grade, AC, 50 Hz - 03 Nos. (for starter) (d) 15 HP Fully automatic starter delta starter (FASD) - 03 Nos. (e) Multifunction Meter with CT/ PT - 04 Nos. (f) Indicator Set RYB, “LED” type (set of three) for each starter and main incoming - 04 Set (g) Aluminium Bus bar minimum 150 Amp with R/Y/B coloured for three Phases and 100 Amp for Neutral Black colour insulation sleeves - 01 Set description of item contd....
Description of serial item No. 142 contd… Notes : (i) LT Panel shall be mounted in Wall as directed by Engineer-in-Charge. (ii) The contractor shall produce and get the detailed (GD) drawings of LT Panel approved from GE through Engineer-in-Charge before fabrication and placing the order to the approved manufacturer. (iii) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (iv) Cost of internal wiring, MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with aldrop bolt and any minor addition/alteration where required at site (the decision of GE shall be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
Disconnecting, dismantling & taking down old unserviceable LT Panel Box of any size & capacity including all fixtures/accessories and Supply, installing, commissioning and testing factory made and tested (CPRI approved manufacturer) new indoor type, LT Panel Box cubical type of suitable size (minimum size 4550 x 1225 x 500mm) to accommodate the following accessories, 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, made out of 2mm thick MS CRCA sheet (outer body, doors, etc), inside partitions & cover made out of 2mm thick MS CRCA sheet with modular hinges, powder coated inside & outside with 7 tanks process in approved shade, protection class IP-55 with coloured insulation sleeve, rubber gasket, insulators, indoor type, totally enclosed, weather, dust and vermin proof as per IS, front & rear opening with double door shutters having suitable aldrop bolt locking arrangement, including internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size as directed with proper ferrule & cable glands including connecting incoming and outgoing cables, including danger notice plate, Feeder Name plate, necessary PCC 1:3:6 type C1 in foundation and frame made out of 65 x 65 x 6mm angle iron grouted at minimum 45cm above ground/floor level and 30cm below ground/floor level, comprising & including the following accessories complete all as specified and as directed :- description of item contd....
Description of serial item No. 143 contd… (a) MCCB 400 Amp, 4 Pole, 36 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type - 01 Nos as incoming. (b) MCCB 200 Amp, 4 Pole, 25 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type - 04 Nos as outgoing. (for FASD Starter) (c) MCCB 63 Amp, 4 Pole, 16 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type - 01 No. as outgoing. (for bldg load) (d) 75 HP Fully Automatic Star Delta Starter (FASD MU-G75) - 04 Nos. (e) Multifunction Meter for each starter and main incoming - 05 Nos. (f) Indicator Set RYB, “LED” type (set of three) for each starter and main incoming - 05 Set (g) Aluminium Bus bar minimum 600 Amp with R/Y/B coloured for three Phases and 300 Amp for Neutral Black colour insulation sleeves - 01 Set description of item contd....
Description of serial item No. 143 contd… Notes : (i) Vertical height of legs of LT panel base frame shall be not less than 45 cm from top of nearest road level / PCC floor finish. Legs shall be grouted in ground minimum 30cm in PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate). (ii) The contractor shall produce and get the detailed (GD) drawings of LT Panel approved from GE through Engineer-in-Charge before fabrication and placing the order to the approved manufacturer. (iii) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (iv) Cost of internal wiring, MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with aldrop bolt and any minor addition/alteration where required at site (the decision of GE shall be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
Supply, laying, jointing and testing 35 Sqmm, 3 core, 1100 V grade, ISI marked, flat/ round multistranded copper conductor PVC insulated and PVC sheathed cable with water proof jointing material, laid in trenches, pipe, ducts, cable tray with cable tie properly and necessary electric connection including dismantling & taking out old unserviceable cable, complete all as specified and as directed.
Supply, laying, jointing and testing 6 Sqmm, 3 core, 1100 V grade, ISI marked, flat/ round multistranded copper conductor PVC insulated and PVC sheathed cable with water proof jointing material, laid in trenches, pipe, ducts, cable tray with cable tie properly and necessary electric connection including dismantling & taking out old unserviceable cable, complete all as specified and as directed.
S&F in repair perforated cable tray GI 1.6mm thick of size 150mm x 50 mm for cable laying alongwith nylon tie/ clip duly fixed with proper clamping material complete all as specified and as directed.
S&F in repair perforated cable tray GI 1.6mm thick of size 100mm x 50 mm for cable laying alongwith nylon tie/ clip duly fixed with proper clamping material complete all as specified and as directed.
Disconnecting, dismantling & taking down old unserviceable LT Panel Box of any size & capacity including all fixtures/accessories and Supply, installing, commissioning and testing factory made and tested (CPRI approved manufacturer) new Pedestal mounting, outdoor type, LT Panel Box cubical type of suitable size (minimum size 1000 x 1000 x 450mm) to accommodate the following accessories, 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, made out of 3.15mm thick MS CRCA sheet (outer body, doors, etc), inside partitions & cover made out of 2mm thick MS CRCA sheet with modular hinges, powder coated inside & outside with 7 tanks process in approved shade, protection class IP-55 with coloured insulation sleeve, rubber gasket, insulators, outdoor type, totally enclosed, weather, dust and vermin proof as per IS, front & rear opening with double door shutter having suitable aldrop bolt locking arrangement, including internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size as directed with proper ferrule & cable glands including connecting incoming and outgoing cables, including necessary danger notice plate, Feeder pillar name plate, installed on pedestal mounting of necessary PCC 1:3:6 type C1 in foundation and frame made out of 65 x 65 x 6mm angle iron grouted at minimum 45cm above ground level and 30cm below ground level, comprising & including the following accessories complete all as specified and as directed :- description of item contd....
Description of serial item No. 148 contd… (a) 100 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/ DMC insulator bus bar support (Square/ Round) insulators of suitable size and good insulation resistance. (b) MCCB 4 Pole, 63 Amps, Rotary Handle, adjustable Thermal Magnetic relay breaking, breaking capacity 36 kA at 415 volts Ics=100% Icu - 01 No. as incoming (c) Indicator lamps (LED type) & bakelite fuse showing R,Y,B phase - 01 Set (d) Multifunction meter - 01 No. (e) MCB 4 Pole, 32 Amp, breaking capacity 10 kA, 415 volts - 01 No. (outgoing) (f) Digital type Single phase preventer - 01 No. (g) Motor protection circuit breaker of suitable range of pump set - 01 No. (h) Panel mounted Fully Automatic Star Delta Starter relay range 11 to 18 Amps conforming to IS -1347 (Par IV) Suitable for 15 to 20 HP submersible motor, including overload relay, auto timer with necessary electrical wiring etc complete - 01 No. description of item contd....
Description of serial item No. 148 contd… Notes : (i) Vertical height of legs of LT panel base frame shall be not less than 45 cm from top of nearest road level / PCC floor finish. Legs shall be grouted in ground minimum 30cm in PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate). (ii) The contractor shall produce and get the detailed (GD) drawings of LT Panel approved from GE through Engineer-in-Charge before fabrication and placing the order to the approved manufacturer. (iii) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (iv) Cost of internal wiring, MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with aldrop bolt and any minor addition/alteration where required at site (the decision of GE shall be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
M&L for information sign board of size 60cm x 90cm made of 3mm thick Acrylic sheet for Pump set details etc, printing the details of Centrifugal pump set including motor details, DG sets etc for water supply installation of Navy Pump House, Navy Filtration Plant, Navy Electrical Sub Station, with Navy Blue background & black/white letters suitable for 40mm width of each letter, information printed and sticked with different colour code as per existing or as directed by Engineer-in-Charge, making necessary arrangement to fix on wall with suitable screws, including taking down existing board complete as directed. Note : Letters/matter etc for Information Board shall be given by the Engineer-in-Charge. The lettering font & style, layout of information board, colour of acrylic sheet etc shall be as directed by Engineer-in-Charge.
S&F Pressure Gauge 8" dia type meter range 0-14 Kg/sqcm rating fixed in delivery line of pump set etc, fixed in repairs, complete all as specified & as directed.
Disconnecting & taking out the existing serviceable transformer of capacity upto 500 kVA with all electrical HT/LT connections, earthing of body & neutral from INS Valsura Jamnagar and shifting of transformer to Power House/ Substation at Army Lines Jamnagar and installing & commissioning with necessary fixing arrangement including connecting up electrically, earthings, etc, commissioning and testing (till the existing transformer at Army Lines is repaired under relevant items of this BOQ), disconnecting & taking out the same transformer with all electrical HT/LT connections, earthing of body & neutral from Army Lines Jamnagar and shifting of transformer to INS Valsura Jamnagar and installing & commissioning with necessary fixing arrangement including connecting up electrically, earthings, etc, commissioning and testing, complete all as specified and as directed. Notes : (i) All T&P/Vehicle required for shifting, connection, loading, unloading, etc including necessary petty items like bolts, nuts etc shall be arranged by contractor and rates for the same shall deemed to be included in rate quoted. (ii) If transformer or any connected equipment/part is lost or damaged while in the custody of the contractor, the same shall be provided / repaired by the contractor at his own cost complete to the entire satisfaction of GE.
M/s. Vimal Enterprise (BID ID -3363700)
jagdish machinery stores (BID ID -3365892)
Hirachand Sunderji and co (BID ID -3366668)
JAYESH TRADING CORPORATION (BID ID -3366514)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .