| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.6 LAccepted-AOC | 1 | Accepted-AOC L1 accepted | |
| 2 | 2₹11.3 L+₹1.6 L (17.0%)Rejected-AOC KANNUR | KERALA | 670001 | 2 | Rejected-AOC L2 rejected | |
| 3 | 3₹11.6 L+₹2.0 L (20.5%)Rejected-AOC | 3 | Rejected-AOC L3 rejected |
Tender Value
₹11.9 L
EMD Value
₹29,635
Closing Date
18 Jan 2024, 6:00 pmClosed
Executive Engineer
Office of the Executive Engineer PWD electrical division Thiruvananthapuram
GENERAL-Government Secretariat, Thiruvananthapuram- Renovation to the office of Minister for Revenue at 2nd floor, North block- Providing Electrical installations-Renovation - O/o Minister for Revenue.-General Electrical Work
2024_PWD_642749_1
EDT_ET_29_2023_24
Open Tender
Electrical Works
Item Rate
30 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹29,635
Yes
20 Feb 2024
11 Jan 2024
22 Jan 2024
11 Jan 2024
18 Jan 2024
11 Jan 2024
Amount
Part-1- Electrification
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
90.3.7:Supplying and providing extra steel chain (16 SWG) 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.
90.3.8:Supplying and providing extra steel chain (16 SWG) 4 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.
OD5808/2023-2024:Supply, conveyance, installation, testing and commissioning of pre-wired 3600 lumen square (2ft X 2ft) recessed fitting made of CRCA sheet of thickness 0.5mm, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, (Chip make Cree/Osram/lumilled/Nichea (UGR less than 19) suspended from ceiling properly hooked to steel hooks anchored to the ceiling and giving connections etc. as required.
OD5802/2023-2024:Supply and fixing 1200 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, (Chip make: Cree/Osram/lumilled/Nichea) fixed in fall ceiling including cutting holes and giving connection etc if required.
OD5803/2023-2024:Supply and fixing 1500 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, (Chip make: Cree/Osram/lumilled/Nichea) fixed in fall ceiling including cutting holes and giving connection etc if required.
OD228567/2022-2023:Supply and fixing 1800 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, (Chip make: Cree/Osram/lumilled/Nichea) fixed in fall ceiling including cutting holes and giving connection etc if required.
OD5819/2023-2024:Supply, Conveyance, Installation, Testing and Commissioning of recessed mounted 50mm light Linear light
OD5817/2023-2024:Supply and fixing recessed mounted 5W, 450lm LED down lighter fitting white colour including cutting hole in the ceiling as required.
OD5818/2023-2024:Supply and fixingrecessed mounted 36 degree adjustable 7W, 630lm LED spot light/ wall washer fitting white colour including cutting hole in the ceiling as required. Focus can be adjustable asper requirements.
OD5820/2023-2024:Supply and fixing Surface mounting type Low deep Aluminium Profile for fixing LED strip 8mm X 17mm including fixing ,making good the damages etc as required. (1piece/meter)
OD5832/2023-2024:Supply and installation testing and commissioning flexible LED strip high brightness SMD LED as the light source for indoor application. It is highly suitable for cove-lighting , decorative lighting etc : warm/white :- 45 W LED (Pro Glow), 900 lm/meter having a length of 5 mtr warm/white including drive connection etc
OD228568/2022-2023:Supply, Conveyance, Installation, Testing and Commissioning of surface mounted 10W integrated LED bath room mirror lamp fitting including fixing ,making good the damages etc as required
OD228570/2022-2023:Supply and fixing 10 Watts LED metal body Picture lamp fixed in wall and giving connection etc as required.
1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
OD228571/2022-2023:Supply and fixing metal body wall mounting fan of the following sizes using mounting brackets supplied along with the fan and giving connection etc. as required..- 450 mm sweep metal frame Wall Mounting fan
OD228572/2022-2023:Supply, Installation , testing and commissioning of 225 mm sweep, light duty Exhaust fan in metal frame working on 230 V A/C exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.:-225 mm sweep, light duty Exhaust fan in metal frame working on 230 V A/C
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
OD228573/2022-2023:Supply and fixing 20 mm dia PVC flexible conduit with accessories on surface of wall making good the damages etc as required.
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.14:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm
1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
1.18.2:Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
90.6.9.5:Supplying & Drawing unarmored PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit5 pair
90.6.9.6:Supplying & Drawing unarmored PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit10 pair
1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
1.53.2:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required2 run of Cable
1.53.3:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required3 run of Cable
90.9.1.1:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.50x50mm Cable Management System with base and lid
90.9.1.7:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
90.9.2.2:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider
90.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree
90.9.2.4:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree
90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
90.9.2.11:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable retainer
90.9.2.24:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat Tee
90.9.2.12:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.1 to 3 module mounting box
90.9.2.13:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.4 to 5 module mounting box
90.9.2.14:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.8 module mounting box
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
OD5986/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. RJ 45 Socket Outlet
OD5987/2023-2024:Supply and crimping transparent type RJ45 male connector with gold plated contacts used for solid and standard network wires- RJ45 connector
1.24.6:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
1.24.7:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet
1.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
OD5876/2023-2024:Supply and fixing flush mounting POP-UP boxes with installation kits for fixing in furniture -4 Module Matt Steel Finish
OD5878/2023-2024:Supply and fixing flush mounting POP-UP boxes with installation kits for fixing in furniture -8 (2x4) Module Matt Steel Finish
1.38:Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
OD5991/2023-2024:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 40amps 240 volts "C" curve DP Isolator complete with connections, testing and commissioning etc. as required.
OD5993/2023-2024:Supplying and fixing FP sheet steel enclosure on surface/ recess along with 40 amps 415 volts "C" curve FP Isolator complete with connections, testing and commissioning etc. as required.
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD14182/2023-2024:Charges for dismantling the tube lights, ceiling fans, wall fans and conveyance to section store.
OD14292/2023-2024:Charges for dismantling the PVC conduits with copper wire, network cables, telephone cables etc. and conveyance to section store.
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY
SHINU P S
Bidder Name
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY
K.Reghunathan
SHINU P S
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_981949.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .