Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹40.3 LAccepted-AOC | 1 | Accepted-AOC Lowest and eligible bidder | |
| 2 | 2₹41.9 L+₹1.6 L (3.93%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹42.2 L+₹1.9 L (4.70%)Rejected-Finance | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹42.8 L+₹2.5 L (6.15%)Rejected-Finance | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹43.4 L+₹3.1 L (7.63%)Rejected-Finance | 5 | Rejected-Finance Not being lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
2 Aug 2021, 6:00 pmClosed
Garrison Engineer Kota
Opp Circuit House, Station Road, Kota - 324001
COMPREHENSIVE B/R REPAIR INCLUDING INTERNAL WIRING IN CERTAIN JCOs/ORs/CIVILIAN MD ACCNS IN CENTRAL SECTOR AT MILITARY STATION KOTA
2021_MES_459687_1
8528/E8
Open Tender
Civil Works
Item Rate
183 days
Kota
Class D category a(i)
9 documents required · 9 mandatory
₹500
GE Kota
₹80,000
Yes
27 Aug 2021
14 Jul 2021
10 Aug 2021
14 Jul 2021
2 Aug 2021
28 Jul 2021
15 Jul 2021 - 21 Jul 2021
Amount
Taking down cement plaster of any description and thickness on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
Dismantling floor, hearth or wall tiling/ terrazzo including cement mortar bedding (but not backing), removing tiles and rubbish off the premises, complete all as specified and directed.
Demolition of cement concrete unreinforced of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and pavings n.exc 15 cm thickness (below or above GL), complete all as specified and directed.
Demolition/Dismantling of existing normal roof treatment, any type from RCC roof slab including lime concrete/PCC padding over roof, removing layer of bitumen under lime concrete/PCC padding, cement mortar, felt etc and cleaning the surface by hacking to receive plaster and removing demolished materials outside MD land, complete all as specified and directed.
Demolition of brick work/stone boulder masonry, built in CM incl all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed.
Taking down chowkhat or frames not exc 1.50 Sqm each with shutters (with out taking off shutters from the frame), complete all as specified and directed.
Taking down chowkhat or frames exc 1.50 Sqm and not exc 4.00 Sqm each with shutters (with out taking off shutters from the frame), complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm and not exc 2 Sqm each complete all as specified and directed.
Dismantling cast iron or reinforced concrete concrete drain pipes 100 mm bore, jointed in CM and taking out from trenches if required, complete all as specified and directed.
Dismantling cast iron or reinforced concrete concrete drain pipes 75 mm bore, jointed in CM and taking out from trenches if required, complete all as specified and directed.
Taking up or down 15 mm dia steel tubing and connection including cleaning for refixing or removal to store, complete all as specified and directed.
Taking up or down 20 mm dia steel tubing and connection including cleaning for refixing or removal to store, complete all as specified and directed.
Dismantling water storage tank of any description of capacity exc. 250 ltr but n.exc. 500 ltr, complete all as specified and directed.
Dismantling water storage tank of any description of capacity exc. 500 ltr but n.exc. 1000 ltr, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
Refixing of shutters exc. 1 Sqm but n. exc. 2 Sqm each in same or other opening after easing and adjusting including renewal of screws etc. complete all as specified and directed
Refixing of shutters n. exc. 1 Sqm each in same or other opening after easing and adjusting including renewal of screws etc. complete all as specified and directed
M&L Framed work as in doors or gates of angles or other section with gusset plates, rails braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with including either hooks and hinges or steel hanging door fittings (excluding of steel sheeting or other covering running rails and guides) and hanging also fastening and fixing, conforming to Fe-290 Grade-E-165, complete all as specified and directed.
S&F 35mm thick factory made IInd Class Hard wood (Hollock) paneled door shutters single panel with lock rail and panel of 9mm B.W.P. marine grade plywood bonded with high quality liquid phenol formaldehyde synthetic resin adhesive conforming to IS-710 or 12mm thick particle board veneered with commercial veneering on both faces. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed.
S&F 35mm thick factory made IInd Class Hard wood (Hollock) glazed and skeleton, open rebated, prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered and rounded, fitted with cut and mitered beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed.
M&L for 25 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including provision of suitable blocks for taking mortice locks, latches or other fittings complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing, complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement complete all as specified and directed.
S&F in repair stainless steel tubular curtain rods, 25 mm dia, with fixing brackets and one pair of decorative end caps etc, complete all as specified and directed.
S&F Powder coated (thickness of powder coating minimum 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F Powder coated (thickness of powder coating minimum 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No) hinges type B-21 100mm long (2 No.) suitable handle (1 No), complete all as specified and directed.
Supply only stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm, complete all as specified and directed. (Note: cost of fixing of wire cloth shall be deemed included in the unit rates of item No. 27.00 herein before.)
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in- charge.
S&F 100 mm Hasp and staple, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as specified and directed.
S&F for 150 mm mild steel barrel tower bolts, stove enamelled black with bright bolts and fixed, complete all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section 150 mm long and fixed complete all as specified and directed.
S&F aluminium handles, cast type, anodised 150 mm size all as specified and directed.
S&F 100 mm size mild steel butt hinges, ISI marked, medium weight, cold rolled and fixed with screws all as specified and directed.
S&F 300 mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and directed.
S&F Mild Steel bow handles, oval type, stove enamelled black 150 mm long, complete all as specified and directed.
S&F 300 mm long mild steel sliding door bolt clip type stove enamelled black with bright bolt n.less then 12 mm dia and incl a minimium of 6 bolt & nuts, four on bolt plate and two on staple plate complete all as specified and directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples, complete all as specified and directed.
S&F in repair galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S&F Ist class soft wood Beads, straight (any size) for glazed or gauzed joinery, renewed, including mitres etc. and removing old beads to Store, complete all as specified and directed.
Hacking out old broken glass (any thickness size, quality or description) from wooden frame/steel frame, glazing with putty or fixed with beads complete all as specified and directed.
M&L for complete removal of existing treatment from surfaces of walls and applying one coat of 1 to 1.5 mm thick wall care putty as per manufacturer's instructions and over it applying two coats of distemper oil emulsion white or tinted over a coat of primer, complete all as specified and directed.
M&L Glazed ceramic coloured tiles on vertical surfaces 350x 250x7 mm/450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including 10 mm thick rendering in CM 1:4, complete all as specified and directed.
M&L for 25mm thick plain cement concrete 1:2:4 type B-0 (using 12.50 mm graded stone aggregate) as in flooring/sub base finished rough to receive floor finishes/screed complete all as specified and directed.
M&L 15 mm thick screed bed or bedding layer in CM (1:6) for laying floor finishes complete and all as specified and directed.
M&L 20 mm thick screed bed or bedding layer in CM (1:6) for laying floor finishes complete and all as specified and directed.
M&L for joint free non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, fixed on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 10 mm thick rendering in CM 1:4, complete all as specified and directed.
M&L for machine cut kota stone slab as in flooring 20 to 25 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing, complete all as specified and directed.
M&L for machine cut kota stone slab as in skirting, dado, risers etc, 20 to 25 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing, laid over and including 10 mm thick CM 1:4 backing, complete all as specified and directed.
S&F in repair vitreous china wash hand basin white, corner type of size 410x410 mm, excluding chain and plug, taps and porcelain stopper but incl PVC waste pipe of 32 mm dia, 32 mm dia CP brass waste coupling, fasteners for fixing WHB etc, complete all as specified and directed.
S&F pillar taps, cast copper alloy, with capston heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed, complete all as specified and directed.
S&F in repair PVC connection 600 mm long suitable for 15 mm GI pipe with two PTMT nuts & rubber washers, complete all as specified and directed.
M&L for Udaipur green marble work 16 to 18 mm thick glazed (table rubbed and polished) fixed as in cooking plateform, steps, treads, risers, jambs, window cills etc and the like set in cement mortar 1:4 and pointed with white cement using marble dust with admixture of pigment to match the shade of stone, complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) 100 mm thick as in path/sub base etc, finishing the surface fair and even, complete all as specified and directed.
M&L dry clean Sand filling under floors including watering and consolidation, complete all as specified and directed. Note: Depth of sand shall be measured after punning.
M&L Machine pressed precast concrete interlocking paver block any shape and size made with grey cement and pigment, confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, complete all as specified and directed.
M&L precast (factory casted) cement concrete kerb stone casted in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate with plain or interlocking joints (as directed) including weathering, slightly rounded or chamfered angles, placing in position, set and jointed in CM 1:4, complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair faces of brick work or stone masonry surface in cement mortar 1:6, surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair faces of brick work or stone masonry surface in cement mortar 1:4, surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces of ceiling in cement mortar 1:4 including finishing the surface even and smooth, complete all as specified and directed.
M&L brick work with pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), straight or curved on plan exc 6 m mean radius, built in CM 1:6, complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surface in cement mortar 1:6, surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggreate), 75 mm thick as in plinth protection/Path/PCC paving etc including finishing the surface even & smooth without using extra cement, with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where dirtected and providing 6 mm wide joints throughout the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three parts of fine sand by weight), complete all as specified & directed.
S&F in position rotational moulded polyethylene water storage tanks 500 lts capacity (cylinderical vertical with closed top) hoisted and fixed in position, complete all as specified in SSR Part I and as directed.
S&F in position rotational moulded polyethylene water storage tanks 1000 lts capacity (cylinderical vertical with closed top) hoisted and fixed in position, complete all as specified in SSR Part I and as directed.
S&F 20 mm dia ball brass valve, high pressure with polythene float and fly nut, screwed down for iron pipe, complete all as specified and directed.
S&F in repair 20 mm dia ball brass valve, high pressure with polythene float and fly nut, screwed down for iron pipe, complete all as specified and directed.3
S&F in repair sink with draining board made of stainless steel 1mm thick with plugs, washers and waste coupling, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets of suitable angle iron, 32 mm dia superior quality PVC waste pipe and connecting union to pipe overall size 1200 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
S&F in repairs 'D' type towel rail 60 cm long, CP brass, fancy type, 20 mm dia complete fixed with steel screws complete all as specified and directed.
Supply, fixing, laying & testing 15 mm bore galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket, reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed to walls, ceilings or floors, complete all as specified and directed.
Supply, fixing, laying & testing 20 mm bore galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket, reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed to walls, ceilings or floors, complete all as specified and directed.
Refixing old steel tubing (With and including new GI fittings) in new or old position (Wall, Ceiling, floor etc) of 15 mm dia pipe complete all as specified and directed.
Refixing old steel tubing (With and including new GI fittings) in new or old position (Wall, Ceiling, floor etc) of 20 mm dia pipe complete all as specified and directed.
S&F in repair swivel shower rose of PTMT any colour for fixing with 15 mm pipe (minimum weight not less than 40 gms) with shower arm 15 mm size, 195 mm long with bend of 45 degree with flange of PTMT (minimum weight not less than 40 gms), complete all as specified and directed.
S&F in repair PVC connection 450 mm long suitable for 15 mm GI pipe with two PTMT nuts and rubber washers complete all as specified and directed.
S&F in repair angle valve 15 mm nominal dia cast copper alloy, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed, complete all as specified and directed.
S&F in repair stop valves 15 mm nominal bore, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfllly handles, screwed both ends for iron pipe or for brass ferrule or to GI socket complete all as specified and directed.
S&F in repair 15 mm bore fancy type CP brass wall mixer for mixing hot and cold water with two stainless steel wall flange, screwed down for iron pipe and fixed, complete all as specified and directed.
S&F in repair stop valve 20 mm nominal bore cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed.
S&F in repair bib taps, cast copper alloy, with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest incl providing lime concrete bedding and connecting to flusing cistern complete all as specified and directed.
S&F in repair 15 mm dia fancy type CP brass centre hole basin mixer for mixing hot and cold water, screwed down for iron pipe and fixed, complete all as specified.
S&F in repair 10 Ltr capacity PVC low level flushing cistern, top push type with inlet ball valve, PVC float, brackets including superior quality PVC flush pipe of 32 mm dia, complete all as specified and directed.
M&L applying two coats of synthetic enamel paint over a coat or pink primer on wooden surfaces not exc 10 cm width or girth incl preparation of the new surfaces, complete all as specified and directed.
S&F in repair 75 mm dia PVC (SWR) floor trap, with CP grating including jointing to waste pipe with solvent cement and fixed in cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) complete all as specified and directed.
S&F sand cast iron soil, waste and vent pipe 100 mm bore in any length with or with out ears with cement joints laid in trenches or fixed to walls, complete all as specified and directed.
S&F sand cast iron soil, waste and vent pipe 75 mm bore in any length with or with out ears with cement joints laid in trenches or fixed to walls, complete all as specified and directed.
S&F 100 mm bore CI bend (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
S&F 75 mm bore CI bend (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
S&F in repairs PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints and laid in trenches/floor, complete all as specified and directed.
S&F in repairs PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and laid in trenches/floor, complete all as specified and directed.
S&F PVC (SWR) bend 110 mm bore, any radius, incl jointing to waste pipe with solvent cement, complete all as required and as directed.
S&F PVC (SWR) 110 mm bore single Junction 'T', equal or unequal, incl jointing to waste pipe with solvent cement, complete all as specified and directed.
S&F PVC (SWR) 75 mm bore single Junction 'T', equal or unequal, incl jointing to waste pipe with solvent cement, complete all as specified and directed.
S&F PVC (SWR) bend 75 mm bore, any radius, incl jointing to waste pipe with solvent cement, complete all as required and as directed.
S&F in repair pillar taps, cast copper alloy, with capston heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed.
S&F in repairs 32 mm bore waste fittings brass CP for wash hand basin etc with long screwed and fly nuts, flange end embedded in red lead cement and other end fixed, complete all as specified and directed.
S&F in repair 32mm dia waste coupling of PTMT (half or full threaded) minimum weight not less than 45 grams, complete all as specified and directed.
S&F Grating round 140 mm size of PTMT (Minimum weight 50gms), complete all as specified and directed.
M&L for preparing new steel surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.
M&L applying 2 coats of synthetic enamel paint over a coat or pink primer on wooden surfaces, exceeding 10 cm in width or girth, incl preparation of the new surfaces complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying 1 to 1.5 mm thick wall care putty as per manufacturer's instructions and over it applying two coats of distemper oil emulsion over a coat of primer, complete all as specified and directed.
M&L applying three coats of white wash after preparation of new plastered surfaces of ceiling, complete all as specified and directed.
M&L for applying two coats of cement based paint on newly plastered surfaces of walls over a coat of cement primer including preparation of surfaces, complete all as specified and directed.
S&F in repairs PTMT alloy toilet cabinet with mirror of overall size 350x450 mm and fixed to wall complete all as specified and directed, complete all as specified and directed.
S&F in repairs soap dish vitreous china white, approx size 160x160x90mm, embedded in wall, complete all as specified and directed.
S&F in repairs glass shelf assembly of 6 mm thick glass, 12 cm wide and 60 cm long and CP guards of approved quality and fixed to wall with CP brass screws etc, complete all as specified and directed.
S&F in repair cast iron (malleable) or mild steel casement stay of size 300 mm, with hinged joint and two plates, with studs, complete all as specified and directed.
S&F in repair shower rose 125mm size, CP brass, including fixing to GI pipe or union, complete all as specified and directed.
Cleaning and removing all scale and dirt, etc., from tanks and from mouths of circulating pipe etc., capacity of tank exc. 250 ltr but n.exc. 500 ltr, complete all as specified and directed.
Cleaning and removing all scale and dirt, etc., from tanks and from mouths of circulating pipe etc., capacity of tank exc. 500 ltr but n.exc. 1000 ltr, complete all as specified and directed.
M&L for PCC 1:2:4 mix type B-0 (Using 12.5 mm graded stone agg) for filling in pressed steel frames, roof padding, leveling course to receive floor finishes etc complete all as specified and directed.
M&L brushing neat cement slurry with 3.00 kg cement per Sqm, complete all as specified and directed.
M&L for applying 20 mm thick screed in CM 1:3 on roof slabs with using liquid water proofing compound as per manufacturer's instructions, complete all as specified and directed. (Liquid WPC shall be measured and paid separately).
M&L for applying 15 mm thick rendering in CM 1:4 on stone masonry surfaces with using liquid water proofing compound as per manufacturer's instructions, complete all as specified and directed. (Liquid WPC shall be measured and paid separately).
Supply only integral liquid water proofing compound, complete all as specified and directed.
M&L for cleaning of roof slab including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish, reinforced with non-woven polyester mat with a thermo fusable finish, laid over compatible bitumen primer @ 0.40 Kg/Sqm, torching overlaps with propane or butane gas torch, with an overlap of 75mm at the sides and 100mm at the ends and sealing, complete all as per manufacturer’s instructions, specified and directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm.
Item 121.00 Contd……. (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimney/other vertical surfaces and polymeric membrane shall be inserted in groove and sealed with paving bitumen. (v) Cost of these factors shall be deemed included in the unit rates.
M&L for cleaning of walls and floor of sunken portions including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over cold applied bituminous primer conforming to IS: 3384 @ 0.40 Kg/Sqm, torching overlaps with a propane or a butane gas torch with an overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold applied bituminous primer all as per manufacturer’s instructions, complete all as directed. Note: (i) The waterproofing treatment shall be got carried out through the manufacturer or their authorized applicators only.
M&L for complete removal of existing treatment from surfaces of walls and applying one coat of 1 to 1.5 mm thick wall care putty as per manufacturer's instructions and over it applying two coats of cement based paint of any tint over a coat of primer, complete all as specified and directed.
M&L applying one coat of white wash after preparation of old previously treated plastered surfaces of ceiling, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for reuse or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Dismantling unserviceable main switch/DBs incl wooden board and deposit to MES store yard including making good disturbed surface of wall complete all as specified and directed.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surface, complete all as specified and directed.
M&L for Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface including making good disturbed surface all as specified and directed for the following: - One light/ceiling fan/exhaust fan/bell buzzer point controlled by one, one way switch of 5/6 Amps.
One 5 Pin, 5/6 amps socket outlet point on independent board, controlled by one, one way 5/6 Amp switch.
One 5 Pin, 5/6 amps socket outlet point on same board, controlled by one, one way 5/6 Amp switch.
One light point controlled by two 2 way 5/6 Amp switches.
M&L Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 2.5 Sqmm, with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable FRLS of size 2.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface for one socket outlet 15 amp on independent board including making good disturbed surface, complete all as directed and specified.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, two way, ISI marked, complete all as specified & directed.
Supply and fixing switch socket combination, 5/6 and 15/16 Amps, 230 volt, multi pin, flush type universal, complete all as specified and directed.
Supply and fixing socket outlet, 5/6 Amps, 230 volt, five pin, flush type universal, complete all as specified and directed.
S&F stepped type electronic fan regulator, flush type, 230 volts AC, single pole, humming free, fixed on the existing phenolic laminated sheet, complete all as specified and directed.
S&F ceiling rose surface type PVC/Polycarbonate isolated body, 65x 20mm, 3 terminals, complete all as specified & directed.
S&F in replacement wall mounted LED Tube light fittings, batten type with bipin holders, powder coated steel with retrofit 18 watt LED tube, internally prewired, complete all as specified and directed.
S&F in replacement wall mounted LED Tube light fittings, batten type with integrated LED tube, powder coated steel with retrofit 11 watt LED tube, internally prewired, complete all as specified and directed.
S&F in replacement LED building security light fitting, 25 watt, pressure die cast aluminium housing with IP 66 deg of protection, complete with 1.20 m long street light bracket made of 40 mm bore GI light grade tubing including necessary clamps, nuts, bolts, washers etc, complete all as specified and directed.
S&F PVC/polycarbonate lamp holder, angular/batten type with back plate, complete all as specified & directed.
S&F bell push, flush type, single pole, AC, 240 volts, 5/6 amps,complete all as specified and directed.
S&F Electronic call bell, ding dong type, single pole, 230 volts AC, complete all as specified and directed.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volt, 10 KA 'B' curve including all accessories, complete all as specified and directed.
S&F MCB, 6 to 40 Amps, Single Pole & Neutral, 240 Volt, 10 KA 'B' curve including all accessories, complete all as specified and directed.
S&F MCB, 63 Amps, Triple Pole & Neutral, 415 Volt, 10 KA 'B' curve including all accessories, complete all as specified and directed.
M&L for MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, earth bar and Din rail, 415 Volts TPN with 4 ways, Double door, complete all as specified and directed.
M&L for MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, earth bar and Din rail, 240 Volts SPN with 8 ways, Double door, complete all as specified and directed. Note for items of MCB DB - (1) The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall. (2) The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed FRLS multistranded copper conductor cable of size 4 Sqmm LT, 1100 volts grade, drawn through and including 25 mm dia PVC non metallic surface conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 4 sqmm single core multistranded FRLS copper conductor cable green colour as earth continuity conductor, complete all as specified & as directed.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed FRLS multistranded copper conductor cable of size 6 Sqmm LT, 1100 volts grade, drawn through and including 25 mm dia PVC non metallic surface conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 6 sqmm single core multistranded FRLS copper conductor cable green colour as earth continuity conductor, complete all as specified & as directed. NOTE for items of submain wiring:- Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 25mm dia shall be measured as one run length. Cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the PVC conduit.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 100x100 mm and 50 mm deep, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 175x100 mm and 50 mm deep, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 200x150 mm and 50 mm deep, complete all as specified and directed.
S&F PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 250x200 mm and 50 mm deep, complete all as specified and directed.
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized iron earth wire of 4 dia by means of bolts, nuts, check nuts and washers of galvanized iron including 15 mm bore light grade GI tubing for protection of earth wire, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 5 and complete all as specified and directed. Notes: - (a) Irrespective of whatever is shown in plate No 5 of SSR, earth pit shall be casted in PCC (1:3:6) type C-1 and precast cover of RCC (1:2:4) type B-1 with suitable handle. (b) Item includes the cost of GI pipe for protection of earth wire and earth wire upto 7.5 m. Any variation below or above shall be measured and paid for separately under relevant item of this Sch ‘A’.
S&F earth continuity conductor or main earthing lead, fixed to walls on batten of recess or chases or buried in ground or drawn in existing couduit or fixed tompoles or any other indicated situation 4 mm dia Galvanised iron earth wire, complete all as specified and directed.
Supply, laying, connecting and testing cable PVC insulated armoured and XLPE PVC sheathed LT 1100 volts grade with aluminum conductor of size 25 Sqmm 3.5 core, including disconnecting and taking out existing cable, complete all as specified & directed.
M&L dry clean Sand filling in trenches around underground cables for earth cushion, complete all as specified and directed. Note: - Depth of sand shall be measured after punning.
Supplying and laying pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), laid flat adjoining each other as in protection to UG cables, complete all as specified and directed.
M&L 40 mm bore Steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep for foundation etc or for shafts, column footings or for laying cables etc not exc 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed.
Returning filling in excavated soil including spreading, levelling, watering and well ramming in layers not exc 25 Cm, complete all as specified and directed.
Removing excavated materials (soil) not exc 50 m distance and depositing where directed at a level not exc 1.5 m above the starting point, complete all as specified and directed.
S.S Enterprises
TARKESHWAR DASS CONSTRUCTION COMPANY
Ganesh Contruction
K B ENTERPRISES
SHREEKRISHNA INFRASTRUCTURE
M/s Prem Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .