Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC GALI NO 4 GAUSHALA ROAD VIKASH NAGAR RAMGARH CANTT RAMGARH JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L1 | Accepted-AOC Bid is lowest and reasonable | |
| 2 | L2₹36.3 L+₹34,878 (0.97%)Rejected-AOC VIKASH NAGAR GAUSHALA RAMGARH CANTT 829122 RAMGARH JHARKHAND | RAMGARH | JHARKHAND | 829122 | L2 | Rejected-AOC Bid is not lowest and reasonable | |
| 3 | L3₹37.0 L+₹1.0 L (2.90%)Rejected-AOC S NO 41 4K JAIHIND SOCIETY GANESH NAGAR NEAR ANAND PARK VADGAON SHERI PUNE 411 014 | PUNE | PUNE | MAHARASHTRA | 411014 | L3 | Rejected-AOC Bid is not lowest and reasonable | |
| 4 | L4₹41.3 L+₹5.3 L (14.8%)Rejected-AOC | L4 | Rejected-AOC Bid is not lowest and reasonable |
Tender Value
₹37.9 L
EMD Value
₹75,760
Closing Date
21 Dec 2022, 6:00 pmClosed
GE RAMGARH
GE RAMGARH CANTT
PROVN OF DRILL SQUARE SHED AT SRC UNDER GE RAMGARH CANTT
2022_MES_564265_1
8300/3143/E8
Open Tender
Civil Works
Item Rate
180 days
GE RAMGARH CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE RAMGARH
₹75,760
Yes
17 Jan 2023
23 Nov 2022
23 Dec 2022
23 Nov 2022
21 Dec 2022
7 Dec 2022
Amount
Excavation in post holes (or similar holes) not exceeding 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick as in soft disintegrated rock including watering & removing surplus soil material to a distance not exceeding 50 mtr & making good surface complete all as specified & directed.
M&L for plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed.
M&L for 100 mm thick plain cement concrete 1:2:4, type B-2 (using 40 mm graded crushed stone aggregate) as in sub base to flooring/hard standing etc ,complete all as specified and directed.
M&L for Brick work using old size bricks , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 etc complete all as specified & directed.
S&F roof trusses (framed), trussed, purlins, crane gantries ,rail,rafter, heavy bracket framing (beam, tee, angle, channel or flat sections) distance pieces, cleats,fastening including fabrication and fixing conforming to Fe-410-W(Gde E-250) quality-A complete all as specified & directed.
S&F bands, straps, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; hand made sliding bolts; clamps;hold fasts; wall ties; plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L for prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
M&L for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed
S & F for plain black mild steel sheet 0.80mm thick as in ridge ,hips,valley,gutters,drip & straight flashing (length & girth as fixed)fixed with self tapping screws as specified.
S & F fo Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
M & L for machine cut kota stone slab flooring 22 -25mm thick over & including 20mm thick screed bed in cement mortar (1:6) as in step tread in one piece in one step, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including moulding , grinding,rubbing and polishing complete all as specified and directed.
M&L for machine cut kota stone slab in skirting 18 to 22 mm thick, laid and jointed with grey cement slurry pointed with coloured cement to match the shade of the slab including grinding rubbing & polishing over 10 mm thick backing coat in CM (1:4) etc complete all as specified & directed.
M&L for rendering 15 mm thick on brick masonry/concrete surface etc in CM (1:4) in two layer ,surface finished even & smooth without using extra cement with & including water proofing compound complete all as specified and directed. (Note:Water proofing compound shall be measured and paid seprerately under respective item of "BoQ")
Supply only liquid water proofing compound (ISI marked )complete all as specified and directed.
S & F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed on walls, including PVC clamps etc. complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of newly plaster surface wall and applying two coats of cement base paint over a coat of alkali primer including necessary scaffolding complete all as specified & as directed.
M&L for point wiring for one light/fan/exhaust fan point /exhaust fan/ bell /buzzer point controlled by one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 1.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system & 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steel sheet terminal box made out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including PVC board with bakelite sheet 2.8 mm thick laminated cover make sheet for housing/fixing switches etc., complete all as specified and directed. Note: Proper colour coding to be adopted.
All as per item No 17 here-in-before but 5 Amp socket outlet on same board.
All as per item No 17 here-in-before but for 5 Amp switch socket on independent board.
M&L for point wiring with FRLSH PVC insulated PVC sheathed electric cable confirming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 2.50 Sq.mm nominal cross sectional area for phase & neutral & including non metallic rigid PVC conduit ISI marked medium grade not less than 25 mm dia with all conduit accessories in concealed wiring system & 2.50 Sq.mm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including pressed steel anodized sunken boxes 60 mm deep & 1.6 mm thick duly painted inside & anticorrosive outside with Bakelite hylem sheet 2.80 mm thick complete for one six pin switch socket outlet combination ,15 Amps & 5 amp socket point on independent board controlled by one ,one way switch complete all as specified and directed.
S & F switch piano flush button single pole one way 5 Amp, complete all as specified and as directed.
S & F socket outlet 2 in 1, 3 pin, 5Amp, flush type, universal, complete all as specified.
S & F Switch socket combination 2 in 1, 3 pin, 5Amp and 15 Amp flush type, universal, complete all as specified.
S & F Switch socket combination 2 in 1, 3 pin, 5 Amp, flush type, universal, complete all as specified.
S & F ceiling rose three terminals PVC/ Polycarbonate, isolated body complete all as specified.
S & F LED light fitting 1 x 20watt , 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engr-in-Charge. Make: Havells/Bajaj/Crompton Greaves/Phillips.
S & F sheet metal enclosures for DBs when MCBs to used single pole and neutral (SPN) single door 240 volts, 4 way with IP-43 IK-09 protection including 200 Amp bus bar and neutral link (ISI marked), complete all as specified and as directed.
S & F amp rating 240V, 10 kA 'C' Curve miniature circuit breaker (MCB) of single poles and neutral and current carrying capacity 32 Amp in the MCB DB complete with connection testing and commissioning all as specified and as directed. Make: IndoAsian or its equivalent make in Havells/Standard/L&T.
S & F 240V, 10 kA 'C' Curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp in the MCB DB complete with connection testing and commissioning all as specified and as directed. Make: IndoAsian or its equivalent make in Havells/Standard/L&T.
M & L Sub main wiring two single core 4.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 4.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 25 mm dia, complete and making good disturbed surface wall complete all as specified and as directed. Note : - 2 runs of 4 Sqmm cable and 1 run of earth wire 4 sqmm shall be measured as one unit length.
Supply and laying for fixing or passing through pipe, 1100 volts grade, armoured heavy duty cable with XLPE insulated aluminium conductor 16 Sq mm, 2.0 core nominal cross section in stranded conductor, including testing, complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth and getting out for laying cable/pipes as in hard/dense soil, complete all as specified and as directed.
Removing excavated materials n.exc. 50 m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm, complete all as directed.
M & L for sand cushioning for protection of underground cables, consolidated and compacted with clean dry sand all as specified and as directed by Engr-in-Charge. Note: The depth of sand shall be measured after puning only.
M&L for reinforced precast concrete cable cover class LV, type 2, flat, size 250 mm x 150 mm x 40mm all as specified and directed
M&L ,for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts & washers of galvanised iron or steel, protected by GI pipe 15 mm bore (light grade) and watering pipe 20 mm bore GI pipe (light grade) and PCC of chamber and coping shall in 1:3:6 type C-1 using 20 mm graded stone aggregate including excavation and earth work and removal of surplus soil and filling with black cotton soil upto ground level complete all as shown in electrical plate No 3 of SSR Pt-I, 2009 with CI cover 10mm thick of size 300x300mm with charcoal dust and common salt complete and earth lead connected to panel including testing complete all as specified and directed. Note : Earth test result should not less than one ohm.
S & F 25 mm bore GI tube, light grade pipe, for cable protection complete with all fittings laid as in floor etc., complete all as specified and as directed.
M/S Parmar Construction
OM INFRA
Barehar Construction Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .