Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹62.7 LAccepted-AOC CANADA BUILDING 224 DR D N ROAD FORT MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹64.9 L+₹2.1 L (3.35%)Rejected-AOC ENKAY TOWN PLAZA B I BLOCK PALAM VIHAR GURUGRAM HR 122017 | GURUGRAM | GURUGRAM | HARYANA | 122017 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹65 L+₹2.3 L (3.59%)Rejected-AOC 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE KALIMATA MANDIR ROAD PATHANKOT PUNJAB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC Not Lowest |
Tender Value
₹65 L
EMD Value
₹1.2 L
Closing Date
19 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE HILLS Dehradun
HQ CWE HILLS Dehradun, MALL ROAD, DEHRADUN CANTT- 248003.
PROVISION FOR FD ELECTRIFICATION OF AVIATION BASE KALA GROUND AT CLEMENT TOWN DEHRADUN
2022_MES_557869_1
85384/CLT/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE Clement Town
Class C Category b(i)
8 documents required · 8 mandatory
₹1,000
Yes
GE Clement Town
₹1.2 L
Yes
19 Dec 2022
15 Oct 2022
26 Nov 2022
15 Oct 2022
19 Nov 2022
7 Nov 2022
Amount
Supply, installation, testing & commissiong of elevated type high intensity LED type runway light fitting, minimum 35 watt and upto 65 Watts (The wattage of light fitting shall be provided as per the ground requirement in accordance to standard technical norms), 6.6A, having 360 degree clear light output complete with breakable coupling, gaskets, two pin secondary lead plugs, base plate with six numbers M10 stainless steel bolts, spring and plain washers and other accessories suitable for confirming to ICAO requirements complete all as specified and directed.
Supply, installation, testing & commissiong of Bi-directional high intensity LED Type runway centre line inset fitting, 35 Watts, 6.6 Amps, two pin secondary leads plugs, shallow base suitable for confirming to ICAO requirements complete all as specified and directed.
Supply, installation, testing & commissiong of Uni-directional medium intensity LED Type runway red stop bar inset fitting, 15 Watts, 6.6 Amps, two pin secondary leads plugs, shallow base suitable for confirming to ICAO requirements complete all as specified and directed.
Supply, installation, testing & commissiong of Uni-directional elevated type high intensity halogen type runway approach light fitting, 200 Watts, with and including halogen Lamp complete with prefocussed halogen lamp reflector, front glass, breakable coupling, gasket, filter (green for threshold and red for stopway fitting) two pin secondary leads plugs, base plate with six numbers M10 stainless steel bolts, spring and plain washers and other accessories suitable for confirming to ICAO requirements complete all as specified and directed.
Supply, installation,testing & commissiong of Uni-directional elevated type high intensity hlogen type runway threshold Lighting cum Runway end light fitting, 200 Watts, with and including halogen Lamp, complete with prefocussed halogen lamp reflector, front glass, breakable coupling, gasket, filter (green for threshold and red for stopway fitting) two pin secondary leads plugs, base plate with six numbers M10 stainless steel bolts, spring and plain washers and other accessories suitable for confirming to ICAO requirements complete all as specified and directed.
Supply, installation,testing & commissiong of medium intensity elevated type omni directional LED type taxiway edge light fitting, 7.5 Watts LED with all accessories including blue lens, breakable coupling, central column assembly, 2 pin secondary lead, rubber gaskets, base plates with 6 Nos M10 stainless steel bolts, spring washer and other accessories etc suitable for confirming to ICAO requirements complete all as specified and directed. Note for ser item No 1 to 6 : The cost of all other connected work including materials not mentioned in the specifications but required at site for installation of light fittings are deemed to be included in the quoted rates. No extra payment will be made on account of this. In case of any dispute the decision of Accepting Officer will be final and binding.
Supply, installation,testing & commissiong of 5 KV grade, 50 Hz, series type isolating transformer encapsulated in polyster resin finally moulded in neoprene type rubber with primary & secondary connections of following capacity complete all as specified and directed :-
200 Watts, 6.6/6.6 Amps.
100 Watts 6.6/6.6 Amps.
45 Watts 6.6/6.6 Amps.
25 Watts 6.6/6.6 Amps.
15 Watts 6.6/6.6 Amps.
Supply & making field connections by crimping of 5 KV grade plug and receptacle of type-I class 'B' connector suitable for field attachment with 5 KV grade XLPE insulated PE sheathed single core, 6 Sqmm multi stranded copper conductor cable, confirming latest IS complete all as specified and directed. Note :- XLPE insulated PE sheathed single core 6 Sqmm multi stranded copper conductor cable shall be measured and paid separately.
Supply & making field connections by crimping grade plug and receptacle for 2core, 4 Sqmm secondary cable 1.1 KV grade flexible multi stranded EPR insulated, PVC sheathed conforming to latest IS complete all as specified and directed. Note :- 2core, 4 Sqmm secondary cable 1.1 KV shall be measured and paid separately.
Supply & installation of cast iron transformer housing box, water tight, round type container of outside size 330 mm dia and height 450 mm made of 10 mm thick cast iron moulding all round except top surface which is 15mm thick cast iron moulding should be suitable to recieve a light fitting inside and base plate on the top and under ground housing associated with transformer power cable and having a clear hole at two side surface centre 75 mm above from bottom surface to recieve 50 mm dia (outer dia) HDPE (DWC)/ GI Pipe and including check nut as required and another hole at 175mm from the bottom of CI housing to recieve one No 15mm dia pipe and having clear opening of 220 mm at top surface and 6 Nos M10 tapped hole to recieve light fitting base plate including PCC (1:2:4) typeB1 as required complete all as specified and directed. Note: The cost of all other connected work including materials not mentioned in the specifications but required at site for installation of cast iron housing box are deemed to be included in the rates quoted. No extra payment will be made on account of this. In case of any dispute the decision of accepting officer will be final and binding.
Supply, laying or passing through pipe in trenches/ ducts/ through pipes under road etc & testing of single core cable XLPE insulated 6 Sqmm size, 5 KV grade multi stranded copper conductor, annealed, PE sheathed, unshielded, anti-termite and rodent treated, airport lighting cable complete all as specified and directed.
Supply, laying or passing through pipe in trenches/ ducts/ through pipes under road etc & testing of two core, 4Sqmm size, 1.1 KV grade flexible, multistranded annealed secondary copper conductor, EPR insulated, PVC sheathed, unshielded, anti-termite and rodent treated, airport lighting cable complete all as specified and directed.
Supply and laying of 50mm dia HDPE pipe along with all required fittings, double wall corrugated (DWC), confirming to IS:12430 part II with and including cutting chases in existing bituminous surface to the required depth as under and filling back with PCC (1:2:4) type B1 as required complete all as specified and directed :-.
Depth of upto 200mm for two core 4Sqmm secondary cable
Depth of upto 375mm for single core 6sqmm primary cable.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate, connected by 6 SWG dia GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC (1:3:6) type C-1 with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM (1:4), funnel with wire mesh, RCC pit cover of 320x320x80mm size PCC (1:2:4) Type B1 reinforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
S&F 15mm dia GI pipe light grade with 6 SWG dia GI wire for earth connections from earth electrode as required complete all as specified and directed.
Supply, laying or passing through pipe in trenches/ ducts/ through pipes under road etc 6 SWG dia GI wire on surface or in recess for loop earthing as required complete all as specified and directed.
Supply, installation, testing and commissioning of indoor type, air cooled constant current regulator (CCR), suitable for use on input supply voltage 415 +10%, 50Hz, output power with tapping and output current with 5 steps current variation suitable for local and remote control operation with 24V/48V/ DC control supply with complete digital output ammeter over current, open circuit earth fault protections, earth leakage meter and positive back indication equipments with complete 5kV grade current transformer, relay contacts as required and as per AAI specification.
10 kW, 20 Amp.
6 kW, 6.6 Amp.
2.5 kW, 6.6 Amp.
Supply, installation, testing & commissioning of frangible & LED type illuminated landing direction indicator (Landing-'T') confirming to ICAO Annex 14, volume I and suitable for operation on 230 V, 50 Hz, single phase AC supply and complete with following main components as required :- (a) Alluminium frame alongwith suitable mounting structure. Dimension shall confirm to ICAO Annex 14 and frangibility of structure shall confirm to ICAO Annex 14 & Aerodrome design manual part-6/FAA. The structure shall be powder coated with prepferably aviation yellow paint. (b) 33 nos. <10W nominal capacity LED lamps alonwith Lamps mounting arrangement for outdoor conditions. (c) Landing T indication by illumination and changeover facility. (d) Control box, internal copper wiring, provision for remote control operation. (e) Providing and laying suitable cement concrete foundation for installation of landing H as per OEM recommendation.. Note: The equipment to be provided at site as per above is in accordance to min requirement. However in case superior specifications are required at site due to ground requirment or to meet the minimum technical standard the same will be provided by contractor without any extra cost.The cost of the same deemed to be included in rates quoted.
NSC Projects Pvt. Ltd.
JCC ENGINEERS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .