| Sl No | Description | Qty | Unit | HIND ERECTORS L3 | Popular Engineering and Contractors L1 | DIPAK CONSTRUCTIONS L2 | MBM ENGINEERING WORKS L4 |
|---|---|---|---|---|---|---|---|
| 1.00Replacing of Boiler Bank Tubes (406 Nos.) and replacing of Water wall tubes including the stub joints if required (71 Nos.) for THERMAX make Boiler No.K-798, Capacity 12TPH, @ 22Kg/cm², of Bi-drum type Boiler, at our Palm Oil Mill | |||||||
| 1.01 | 1. Rate for replace in the damaged/plugged tubes as per the drawing details and existing tube dimensions for Boiler Bank tubes except the LHS wall including Testing & Inspection by Factories and Boilers Department for Boiler K-798.
Tube OD 50.8 mm X 3.25 mm Thick X 8000 mm long C.S. Seamless | 406 | Nos | 17,470 ₹70,92,820 | 12,450 ₹50,54,700 Lowest | 13,500 ₹54,81,000 | 32,000 ₹1,29,92,000 |
| 1.02 | 2. Rate for replace in the damaged tubes as per the drawing details and existing tube dimensions for Boiler Water wall tubes including the stub joints if required for left hand side (LHS) & right hand side (RHS) including Testing & Inspection by Factories and Boilers Department for Boiler K-798.
Tube OD 63.5 mm X 4.06 mm Thick X 7600 mm long C.S. Seamless | 71 | Nos | 17,470 ₹12,40,370 | 11,950 ₹8,48,450 Lowest | 13,600 ₹9,65,600 | 62,000 ₹44,02,000 |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
22 Jan 2021, 6:00 pmClosed
Senior Manager - Engineering
ROil Palm India Limited, Kodimatha, Kottayam
Replacing of Boiler Water wall and Banks Tubes for Boiler K- 798 including Cleaning, Testing and Inspection by Factories and Boilers Department
2021_OPIL_406043_1
OP/SME/POM/2020-21/4077
Open Tender
Equipments
Supply
30 days
Palm Oil Mill, Oil Palm India Limited
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.5 L
Yes
30 Jan 2021
14 Jan 2021
25 Jan 2021
14 Jan 2021
22 Jan 2021
14 Jan 2021
14 Jan 2021 - 22 Jan 2021
Amount
Replacing of Boiler Bank Tubes (406 Nos.) and replacing of Water wall tubes including the stub joints if required (71 Nos.) for THERMAX make Boiler No.K-798, Capacity 12TPH, @ 22Kg/cm², of Bi-drum type Boiler, at our Palm Oil Mill
1. Rate for replace in the damaged/plugged tubes as per the drawing details and existing tube dimensions for Boiler Bank tubes except the LHS wall including Testing & Inspection by Factories and Boilers Department for Boiler K-798. Tube OD 50.8 mm X 3.25 mm Thick X 8000 mm long C.S. Seamless
2. Rate for replace in the damaged tubes as per the drawing details and existing tube dimensions for Boiler Water wall tubes including the stub joints if required for left hand side (LHS) & right hand side (RHS) including Testing & Inspection by Factories and Boilers Department for Boiler K-798. Tube OD 63.5 mm X 4.06 mm Thick X 7600 mm long C.S. Seamless
DIPAK CONSTRUCTIONS
HIND ERECTORS
MBM ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .