Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC | L1 | Accepted-AOC Quoted amount is lowest and found reasonable | |
| 2 | L2₹11.8 L+₹64,671.15 (5.82%)Rejected-Finance GALI NO 4 GAUSHALA ROAD VIKASH NAGAR RAMGARH CANTT RAMGARH JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L2 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE | |
| 3 | L3₹12.2 L+₹1.1 L (10.1%)Rejected-Finance VIKASH NAGAR ROAD NO 1 NEAR GAUSHALA RAMGARH CANTT JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L3 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE | |
| 4 | L4₹12.9 L+₹1.8 L (16.4%)Rejected-Finance Q 49 NEAR DEOGHAR COLLEGE MAIN GATE PO PS DEOGHAR JH 814112 | DEOGHAR | DEOGHAR | JHARKHAND | 814112 | L4 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE | |
| 5 | L5₹13.7 L+₹2.6 L (23.4%)Rejected-Finance | L5 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE |
| Sl No | Description | Qty | Unit | M/S KAMLESHWAR SINGH L3 | M/s Ray construction L2 | simplex infra project L4 | M/s Manoj Kumar Gope L5 | Modernage Constructions Pvt. Ltd. L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft /loose soil complete all as specified and directed. | 80 | Sqm | 20 ₹1,600 Lowest | 65 ₹5,200 | 30 ₹2,400 | 35 ₹2,800 | 60 ₹4,800 |
| 2.00 | Excavation in trenches in soft/loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc., not exceeding 10Sqm on plan and not exceeding 1.5m in depth complete all as specified and directed. | 36.75 | Cum | 130 ₹4,777.5 Lowest | 155 ₹5,696.25 | 150 ₹5,512.5 | 220 ₹8,085 | 350 ₹12,862.5 |
| 3.00 | Excavation in trenches in soft/loose soil exceeding 1.5 mtr deep but not exceeding 3.0 mtr and exceeding 1.5 metre wide and getting out soil including forming bottom surface to required slope/ gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc.,not exceeding10Sqm on plan and not exceeding 1.5m in depth complete all as specified and directed. | 5.65 | Cum | 150 ₹847.5 Lowest | 155 ₹875.75 | 200 ₹1,130 | 365 ₹2,062.25 | 400 ₹2,260 |
| 4.00 | Returning, filling in trenches including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge. | 23.78 | Cum | 110 ₹2,615.8 | 120 ₹2,853.6 | 90 ₹2,140.2 | 100 ₹2,378 | 55 ₹1,307.9 Lowest |
| 5.00 | Spreading & levelling in layers not exceeding 25 cm thick & well ramming incl watering as required complete all as specified and directed. | 14 | Cum | 115 ₹1,610 | 100 ₹1,400 Lowest | 110 ₹1,540 | 250 ₹3,500 | 350 ₹4,900 |
| 6.00 | Removal of surplus excavated soil not exceeding 50 mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and directed. | 12.97 | Cum | 120 ₹1,556.4 | 100 ₹1,297 | 100 ₹1,297 | 100 ₹1,297 | 85 ₹1,102.45 Lowest |
| 7.00 | M&L for plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed. | 5.7 | Cum | 4,000 ₹22,800 | 2,200 ₹12,540 Lowest | 3,500 ₹19,950 | 4,900 ₹27,930 | 4,800 ₹27,360 |
| 8.00 | M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in foundation including rafts, footings,plinth beams, and mass concrete etc.complete all as specified and directed.
Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ. | 9.3 | Cum | 5,000 ₹46,500 Lowest | 5,500 ₹51,150 | 6,000 ₹55,800 | 7,800 ₹72,540 | 6,200 ₹57,660 |
| 9.00 | M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in columns,pillars, piers,post and struts etc.complete all as specified and directed.
Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ. | 5.6 | Cum | 5,500 ₹30,800 Lowest | 5,500 ₹30,800 Lowest | 7,500 ₹42,000 | 7,900 ₹44,240 | 6,200 ₹34,720 |
| 10.00 | M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in lintels beam, floor/roof Beams, cantilevers, bressummers, etc complete all as specified and directed.
Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ. | 6 | Cum | 5,000 ₹30,000 Lowest | 5,500 ₹33,000 | 7,000 ₹42,000 | 7,900 ₹47,400 | 6,200 ₹37,200 |
Tender Value
₹14.4 L
EMD Value
₹28,840
Closing Date
16 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE RAMGARH CANTT
RAMGARH CANTT
PROVN OF KOTE FOR ADDL RIFLES OF AGNIVEERS AT PRC AT RAMGARH CANTT
2025_MES_715261_1
8300/3329/E8
Open Tender
Civil Works
Item Rate
180 days
RAMGARH CANTT
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE RAMGARH CANTT
₹28,840
Yes
11 Sept 2025
18 Jun 2025
23 Jul 2025
18 Jun 2025
16 Jul 2025
2 Jul 2025
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft /loose soil complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc., not exceeding 10Sqm on plan and not exceeding 1.5m in depth complete all as specified and directed.
Excavation in trenches in soft/loose soil exceeding 1.5 mtr deep but not exceeding 3.0 mtr and exceeding 1.5 metre wide and getting out soil including forming bottom surface to required slope/ gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc.,not exceeding10Sqm on plan and not exceeding 1.5m in depth complete all as specified and directed.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge.
Spreading & levelling in layers not exceeding 25 cm thick & well ramming incl watering as required complete all as specified and directed.
Removal of surplus excavated soil not exceeding 50 mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in foundation including rafts, footings,plinth beams, and mass concrete etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in columns,pillars, piers,post and struts etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in lintels beam, floor/roof Beams, cantilevers, bressummers, etc complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canpoies deck slabs and in shelves and the like all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
Use & waste of form work to sides of concrete foundation, base of coloumn ,rafts,footings, plinth beams, and plinth beam and similar work for rough finished flat surfaces of concrete complete all as specified and directed.
Use and waste of form work to sides of columns,pillars,piers,post and struts for rough finished surface of concrete complete all as specified and directed.
Use and waste of form work to sides of soffit of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200 mm thick for rough finished surface of concrete complete all as specified and directed.
Use and waste of form work to sides and soffit of lintel Beam,floor/roof Beams, etc for rough finished surface of concrete complete all as specified and directed.
M&L for mild steel TMT bars 08 mm dia and over grade Fe -500 , as in stirrups, spacers & binders ,cut to length, bent to shape required, including cranking bending spirally for hooping for coloumn,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over grade Fe -500 , as in reinforcement ,cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M&L for hard core of broken stone or boulder gauge not exceeding 63mm deposited, spread & leveled in layers not exceeding 15cm thick, watered and rammed to a true surface etc complete all as specified& directed.
M & L for 75 mm thick plain cement concrete (1:3:6) mix, type C-1 (using 20mm graded crushed stone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 75mm deep joints made at 3.00 m in length and filled with bitumen 85/25 grade and sand in the ratio 1:3 including necessary form work , complete all as specified and directed.
M&L for 75 mm thick plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base to flooring/hard standing etc ,complete all as specified and directed.
M &L precast reinforced cement concrete 1:2:4 ,type B-1 (using 20 mm graded crushed stone aggregate) as in kitchen platform, shelves , cover slab, etc. including necessary formwork complete all as specified and directed. Note : Reinforcement will be measured & paid seperately under respective item of BOQ.
M & L glazed ceramic coloured tiles of size 300 mm x 450 mm x7mm thick/350 mm x 250 mm x7mm thick ,as in vertical surface such as dado/skirting etc ,set and jointed in neat cement slurry and pointed in colour cement to match the tiles, over & including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for machine cut kota stone slab as in flooring 20mm -25 mm thick of size not less than 575 mm X 575 mm, over laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing & polishing over & including 20 mm thick screed bed in CM (1:6) complete all as specifed & directed.
M&L for machine cut kota stone slab as in skirtings,riser of steps ,dado & pillar 10 to 12 mm thick laid and jointed with grey cement slurry pointed with cloured cement to match the shade of the slab including grinding rubbing & polishing over 10 mm thick backing coat in CM (1:4) etc complete all as specifed & directed.
M&L for brickwork with fly ash bricks, old size straight or curved on plan exceeding 6m mean radius built in CM (1:6), complete all as specified and directed.
M&L for rendering 10 mm thick on brick masonry/concrete surface etc in CM (1:6) surface finished even & smooth using extra cement complete all as specified and directed.
M&L for 15mm thick rendering (external) on stone masonry surfaces or on other than fair face of brick work or concrete surface in cement mortar 1:4, with liquid water proofing compound @ 200 ml/50 kg per bag of cement , finished even and smooth without using extra cement complete all as specified and directed (Note:Water proofing compound shall be measured and paid seprerately under respective item of "BOQ")
M&L for 5mm thick cement plastering in cement mortar 1:4 on concrete ceiling surfaces finished even & smooth without using extra cement omplete all as specifed and as directed.
M&L for preparation of new plastered surfaces of wall and applying two or more coats of acrylic smooth acrylic emulsion exterior weather proof paint of required shade new work (two or more coats applied @ 1.67 Ltr/10 Sqm and including priming coat of exterior primer applied @ 2.20 Kg/10 Sqm over a coat of 2 mm thick wall care putty,applying by bump roller applicator complete all as specified and directed.
M&L for preparation of newly plastered surface of ceiling and applying two coats of oil emulsion distemper over a coat of primer including necessary scaffolding complete all as specified and directed.
M&L for preparation of newly plaster surface of wall and applying two coats of distemper oil emulsion (OBD) over a coat of alkali resistant primer (from same manufacturer of OBD) including necessary scaffolding complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
M&L for prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide rough finished surface of concrete complete all as specified and directed.
S & F for steel ventilators, with top hung shutter including hing, steel peg stay with glazing bars complete all as specified & directed.
S&F for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing conforming to Fe-410 W Gde-E-250 quality B complete all as specified & directed.
S & F 1.60 mm thick mild steel, plain, black sheet in covering to door shutters, covering to door chowkhats (frames) cut to size edges beaded if directed, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc., as required, complete all as specified and as directed.
M&L for framed work such as grills,gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railing; framework of water tanks and similar work conforming to Fe 290- Gde E -165 & for portions framed and hung as gates, including pintle hinges, stops,hand-made sliding bolts, etc.complete all as specified and as directed
S&F 4.0 mm thick figured glass pin headed type in squares/ rectangular not exceeding 0.5 Sqm in each pane glazing with oil putty or aluminium frame/shutters with rubber neoprene beading complete all as specified & directed.
M & L for application of water proofing treatment using APP modified roof membrane over non accessible/ non approachable RCC roof slab / chajjah / canopy / parapet wall( horizontal/vertical surface) to be executed through approved applicator of the membrane manufacturer/authorized applicator of the manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly & M & L for 10 mm thick cement plastering in cement mortar 1:3 mixed with water proofing compound as per manufacturer instructions(note : WPC will be measured & paid seperately) (b) Applying approved bituminous based primer( conforming to IS: 3384-1995) @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface . (c) Laying not less than 3mm thick APP (Atactic polypropylene Polymer modified prefabricated membrane) modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.00 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gsm/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650 Kg / Sqcm and transverse not less than 450 Kg /Sq.cm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) Applying two coat of bituminious based Aluminium Paint @ 0.3 Kg /sqm over APP Membrane.
M&L for point wiring for one light/fan/exhaust fan point /exhaust fan/ bell /buzzer point controlled by one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 1.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system & 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steel sheet terminal box made out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including wooden board with bakelite sheet 2.8 mm thick laminated cover make sheet for housing/fixing switches etc., complete all as specified and directed. Note: Proper colour coding to be adopted.
All as per item No. 41 above but 1.5 Sqmm for 5 Amp socket outlet on same board with 1.5 Sqmm earth wire complete all as specified and directed.
All as per item No. 41 above but 1.5 Sqmm for 5 Amp switch socket on independent board with 1.5 Sqmm earth wire complete all as specified and directed.
M&L for point wiring with FRLSH PVC insulated PVC sheathed electric cable confirming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 2.50 Sq.mm nominal cross sectional area for phase & neutral & including non metallic rigid PVC conduit ISI marked medium grade not less than 25 mm dia with all conduit accessories in concealed wiring system & 2.50 Sq.mm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including pressed steel anodized sunken boxes 60 mm deep & 1.6 mm thick duly painted inside & anticorrosive outside with Bakelite hylem sheet 2.80 mm thick complete for one six pin switch socket outlet combination ,15 Amps & 5 amp socket point on independent board controlled by one ,one way switch complete all as specified and directed.
S & F switch piano flush button single pole one way 5 Amp, complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin, 05 Amps, universal type complete all as specified and as directed.
S & F switch piano flush button single pole one way 15 Amp, complete all as specified and as directed.
S & F switch socket combination 2 in 1, 3 pin, 5Amp & 15Amp flush type, universal, complete all as specified and as directed.
S&F ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body complete all as specified and as directed.
S&F fan regulator electronic, step type hum free, socket type, suitable for ceiling fans of any capacity, pre wired 230 volts AC 50 HZ supply 100/120 Watt complete all as specified & as directed.
S&F for ceiling fans complete with blades, down rods,electronic fan regulator and accessories, 230 V, 1200 mm sweep. Min air dilivery 210 CFM with service value greater than 6.1 as per BIS, BEE. Five star rated with brushless direct current motor (BLDC) including connecting up with three core flexible copper conductor cable suitable size from ceiling rose to fan terminal with necessary accessories complete all as specified and directed.
S&F lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked) complete all as specified and directed at site.
S & F LED tube light fitting 1 x 18/20watt , 220 V, AC, surface and wall mounted LED batten PVC housing with polycarbonate diffuserand integrated electronic driver complete with all accessories ,driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engr-in-Charge.
S&F 1X9 W/1X10 W watt LED Bulkhead fitting with IP 65 environmental frendly, ultra modern, energy saving mounted decorative oval bulk head edge lit LED luminaire comprising of high brightness LED 230 Volts AC circuit complete all as specified and as directed.
S & F LED bulb of capacity 15 watt , lumen out put (500)lm ,length 102 mm dia, 56 mm , base cap B22 (ISI mark) three star rated lamp complete all as specified and as directed by Engr-in-Charge.
S & F Exhaust fan made of sturdy Engineering plastic of 300 mm sweep with louvers shutter ,single phase ,230 V,50 Hz,1200 RPM AC ,copper winding , including provision of hole, mounting frame, nut, bolts, washer, fasteners etc and connecting exhaust fan to ceiling rose including provision of three core flexible copper cable of size 1.5 sqmm not less than 0.5 mtr long for connection complete all as specified & directed.
S& F sheet metal enclosures powder coated for DBs when MCBs to used single pole and neutral (SPN) double door 240 volts, 08 way with IP-43 IK-09 protection including 200 Amp bus bar and neutral link (ISI marked) EARTH BAR & DIN RAIL confirm to IS:13032-1991 DB complete all as specified and as directed.
S & F amp rating 240V, 10 kA 'B' Curve miniature circuit breaker (MCB) of single poles and neutral and current carrying capacity 32 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
S & F amp rating 240V, 10 kA 'B' Curve miniature circuit breaker (MCB) of single poles and neutral and current carrying capacity 6 to 32 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
M&L for Earthing complete for poles/DBs with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below normal ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point,GI tubing 20mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel & wire mesh, charcoal & salt, 40 mm thick pre-cast RCC cover (1:2:4) type B-1(using 20 mm graded crushed stone aggregate )reinforced with 8mm dia TMT bar @ 75mm c/c both way with mild steel handle 20mm dia round bar , plastering 15mm thick with CM (1:6:) internally and upto 150mm below ground level externally & angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-1(using 20 mm graded crushed stone aggregate ) (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m & returning filling) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I including making good disturbed surface of wall ,floors etc complete all as directed. Notes: -(i) Earth lead & protection pipes length upto & including 7.50 metre. (ii) Earth filling shall be done by vegetable soil. (iii) Soil should be free from stone, boulders, aggregate, gravels etc.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanished steel wire or tape and overall PVC sheathed 16 sqmm 4 core nominal cross section including testing complete all as specified and directed.
Supplying & Laying un-reinforced pre-cast flat concrete cable protection cover of class LV, type- 2, size 250 mm x 150mm x 40mm, factory made, complete all as specified and directed by the Engineer-in-Charge.
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I.
M/s Ray construction (BID ID -3359004)
M/S KAMLESHWAR SINGH (BID ID -3358959)
simplex infra project (BID ID -3352185)
M/s Manoj Kumar Gope (BID ID -3348938)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .