Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹10.5 L+₹17,904 (1.73%)Rejected-Finance | L2 | Rejected-Finance Highest bidder | |
| 3 | L3₹10.7 L+₹39,900 (3.86%)Rejected-Finance BBMB SUNDERNAGAR HIMACHAL PRADESH | SHIMLA | HIMACHAL PRADESH | 172101 | L3 | Rejected-Finance Highest bidder | |
| 4 | L4₹11.6 L+₹1.3 L (12.2%)Rejected-Finance HAMIRPUR ROAD NEAR BUS STAND UNA DISTT UNA HP | UNA | HIMACHAL PRADESH | 174301 | L4 | Rejected-Finance Highest bidder | |
| 5 | L5₹13.4 L+₹3.0 L (29.5%)Rejected-Finance | L5 | Rejected-Finance Highest bidder |
Tender Value
₹9.5 L
EMD Value
₹18,933
Closing Date
25 Jun 2020, 11:00 amClosed
Executive Engineer
Jal Shakti Division Jawali
Improvement and extension of LIS Ghar Jarot under SCSP in Tehsil Jawali District Kangra HP sub head Providing and installation of Polder pumping machinery with allied accessories
2020_HPIPH_37841_1
EE/JSV/DIV/JWL-2020/1590-1639 dt. 06/06/2020
Open Tender
Civil Works - Water Works
Item Rate
30 days
Nagrota Surian
Please refer Tender documents.
6 documents required · 6 mandatory
₹250
EE Jawali
₹18,933
Yes
28 Aug 2020
6 Jun 2020
25 Jun 2020
6 Jun 2020
25 Jun 2020
6 Jun 2020
Amount
Providing suitable Raw water submersible raw water KRTU Pump set capable of Handling 5000 PPM turvidity of KSB makes single end open impeller raw water handling conforming to (Latest) BIS -code. The pump shall be fitted with single vane impeller of suitable alloi for handling raw water as per IS-5669-1970 having oil/grease packed bearing and stain less shaft wound stator of motor side with shaft protection sleeves on pump side ensuring better life for shaft. The impeller of pump shall be directly mounted on extended submersible squirrel cage motor shaft conforming to BIS-9238-1979 with uptodate ammendements of 1450 (N) RPM, totally dust and weather proof with detachable pump casing for double mehanical seal grease, oil, lubricated bearings and provided with stainless steel thrust bearing plate to with stand vertical loadswith minimum wear and tear it should be fitted with device to take up expanion of water on heating of motor nd suitable for operation on 415+10% Volts, 3 Phase, 50 C/S AC Supply. The power of motor should be atleast maximum 10% in excess of power required by the pump in complete operting range with mounting stand/duck foot bend, steel gide wire with mounting hook, lowering chain and standard accessories as per supplied by the manufacturers complete and suitable for ful-fillings the following requirements.
Location of site :- The site is located at a distance of 8 Kms from Nagrota Surian Railway station.
The Altitude of place in which the motor is intended to work :- Altitude of phase is 500 mtr. Above mean sea level.
Type of current :- A.C. Three phase supply with frequency of 50 cycles per second.
Rated Voltage :- 415 (+/-) 10% Treated.
Charactrstics of water : - (a) Temperature 20°C (b) Turbidity upto 5000 PPM (c) Hardness- Mg/Liter (as CaCo3) (d) Alkalinity Mg/Liter (as CaCo3) (e) PH= _______ (f) Total Solids ____ Mg/Litre (h) Other ______
Depth of T/well assembly 0 mtr.
L.W.L. in Gaj Khad 430.00 mtr
Maximum draw down 0.00 mtr.
Center line level of pump 430.00 mtr
Suction Head _____ mtr.
Discharge level of highest point 460.00 mtr
No. of pump required 2 Nos
Discharge required from each Pump 52.03 LPS
Total head in mtr 34.79 mtr.
Length of R/Main 60.00 mtr.
Dia of R/Main 150 mm
No of working hours P/day 16.00 Hours
Limits of pump operction ( - ) 15 % ( + ) 10 % of total head
H.P. Motor /drive unit: - BHP with following margins/multipying factor at duty point whichevear is higher (a) Up to 2 HP = 1.5 (d) 10 to 20 HP = 1.2 (b) 2 to 5 HP = 1.4 (e) 20 to 100 HP = 1.15 (c) 5 to 10 HP = 1.3 (f) Above 100 HP = 1.10
Test Run 7 hours Continueously for 7 days
Providing Cast Iron double flanged sulice valve of Kirlosker/Kilburn/IVC/Fouress/Gled/BHEL/Leader make of size 150mm suitable as per offered pump and class PN- 1.0 having one size higher to delivery size of pump and capable of with standing nominal seat pressure of 10.20 kg/Cm2. (as per IS -780-1984)(P_!) Note The CI. Sluice valve shall conform to IS 780-1984( latest edition) However if the seat pressure exceeds the limits prescribed in BIS 780-1984 then it shall be of cast steel conforming to class -150ASA (seat pressure 21 Kgs/cm 2 or class 300 ASA (seat pressure 52 kg /cm3 as per BS -1414 (API -600)
Supply of Kirlosker/Kartar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make CI. double flanged swing check type reflux valve having by pass arrangement suitable one size higher to delivery size of pump( Size 300 mm dia & class PN-1.0 ) and shall be suitable for with standing nominal seat pressure of 10.20 Kg /Cm^2 ) ( sa per IS - 5312-1984 .
Providing and laying of suitable size copper PVC insulated armoured power 3.5 core cable .confirming to BIS 1554 (Part-I) 1988 of latest with up to date amendements of siemen / Gloster /ICC finollex make from meter of HPSEB-to-MCB / & from OCB to Busbar switch and starter (one cable carrying all three phases ) including all other electrical equipment /accessories such as thimbles ,flexible pipe solder ,nuts and bolts ,cable glands etc. laid in pipes of trenches under floor . The type size and make will be subject to approval of HPSEB autherities . In case of non -acceptance by HPSEB autherities it shall have to be replaced by the tenderer free of coat. a ) Supply side of size 16 mm² square.
Supply & Errection of floor / wall mounted power factor shunt capacitor conforming to BIS : 2834-1986 latest with upto date amendements L & T / BHEL/ GEC/ Machneil /Mager / Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of required KVAR according to HP of motor offered including cable siemens/Gloste/ICC make form busbar chamber to capacitor and also including L&T/LK/Kilburn make ICTP Switches conforming to BIS-4064-1978 or latest with HRC fuses .
Supply of standard make circular dial pressure gauge of suitbale rangs of Feibeg / Bourden / Precision make with all accessories such as stop cock copper tubing etc. Conforming to BIS: 3624-1987 latest with up to date ammendements.
Erection of all equipment from Sr. No. 1 to 4 and 6 including earthing cost of tees, bends , tapers and any other fitting required as per site conditions and as per direction of Engineer- in - charge.
RAJESHWAR SINGH
SHIV KUMAR
SS ENGINEERING WORKS
Vijay Kumar C/O Vasudeva Electricals
sadeep kumar
A.K. Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .