Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.2 LAccepted-Finance | ₹78.2 L | L1 | Accepted-Finance Accepted |
| 2 | Not Admitted-Fee/PreQual/Technical/Finance VILLAGE BENOILI POST THARALI CHAMOLI UTTARAKHAND | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-bid not received |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance GRAM MASOI TEHSIL THALISAIN PAURI GARHWAL UTTARAKHAND 246285 | PAURI GARHWAL | UTTARAKHAND | 246285 | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-bid not received |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected |
| 5 | Rejected-Technical GRAM PO VAN DISTRICT CHAMOLI UTTARAKHAND | - | - | Rejected-Technical Rejected |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
4 Oct 2023, 1:00 pmClosed
Superintending Engineer,7th Circle PWD Gopeshwar
7th Circle PWD Gopeshwar
One Time Maintenance work of Lwani-Suya Motor Road Constructed under PMGSY Scheme in District Chamoli.
2023_pwd_62673_1
4158/50yata-7/2023 dated 22-08-2023
Open Tender
Civil Works - Roads
Item Rate
180 days
Block-Tharali
Please refer Tender documents.
3 documents required · 3 mandatory
₹4,720
Executive Engineer, CD PWD, Tharali
₹2 L
11 Oct 2023
1 Sept 2023
4 Oct 2023
2 Sept 2023
4 Oct 2023
14 Sept 2023
Amount
Excavation in foundation for retaining, breast walls etc, in all types of soils and rocksincluding all lead, lift and disposal of surplus material as per direction of engineer - in- charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction
Random Rubble Stone Masonry laid Dry, in breast walls, retaining walls, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction
Providing and laying of wire crates 3.00x1.50x1.50 in size with GI wire conforming to IS: 280 & IS:4826 in 150mm x 150mm mesh laid with stone boulders. as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications)
Cement plum Masonry with 40% plum & 60% 1:3:6 cement concrete including supply of all material, labour, T&P etc. required for proper completion of the work. As per drawings and technical specifications Clause 802, 803, 1202 & 1203 of MORD Specifiction
Geotextile Filter (Laying of a geotextile filter between pitching and embankment slopes on which pitching is laid to prevent escape of the embankment material through the voids of the stone pitching/cement concrete blocks as well as to allow free movement of water without creating any uplift head on the pitching.)
Hand Packed stone filling in back of wallls including cost of all materials, royality,T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications)
Clearance of land slides in soil and ordinary rock by a bull-dozer D 80 A-12, 180 HP and disposal of the same on the valley side complete as directed by the Engineer-in-charge
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405..[Grading of no-3] (53-22.4 mm size).
Providing and applying tack coat with bitumen VG -10 distributer at the rate of 0.40 kg per sqm Over dry and hungerous surfaces cleaned with hydraulic broom as per Technical Specification Clause 503.
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) BinderProviding, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type B as per Technical Specification Clause 508. 20 mm thick open graded premix carpet using Bitumen VG 10 By Mechanical Means
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type B as per Technical Specification Clause 510. Seal coat using Bitumen ((VG-10 y Manual Means)
Maintenance of Earhen shoulder (stripping of excess soil) Stripping excess soil from the shoulder surface to achieve the approved level and compacting with plate compactor at OMC as per drawings and Technical Specification Clause 1903
(Removal of earth from the choked hill side drain and disposing it on the valley side manually)
Providing edge stones of Size 450x350x100 mm on valley side of formation as perdrawing and technical specification clause 1608.2.6
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 OrdineryKilometre Stone
200m Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
5th Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
Construction of parapet including all material labour T & B etc required for proper completion of the work as per standard Drawing
Construction of Un-reinforced, Cement concrete pavement, thickness as per design, over a prepeared sub base with 43 grade cement or any other type PCC Grade M-30, coarse and fine aggregates conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less then 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (Steel channel, laying and fixing of wedges, steel plates including levelling the formwork and laying and fixing of 125 micron thick polythene film, as per drawing), spreading the concrete with shovels, rakes, compacted using needle, and plate vibrators, finished in continuous operation and curing of concrete slabs for 14 days, using curing compound where specified and water finishing to lines and grade as per drawings and technical specifications.
Mahaveer Bisht
LAXMI DUTT KUNIYAL
Jagat Singh Bisht
Gaurav Singh Khatri
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
finance_75909.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .