Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical KOUSTHUBAM 31 76A 1 MAYANAD KOZHIKODE 673008 | KOZHIKODE | KERALA | 673008 | - | Rejected-Technical L2 |
Tender Value
₹6.4 L
EMD Value
₹16,150
Closing Date
19 Mar 2018, 5:00 pmClosed
ASSISTANT EXECUTIVE ENGINEER
OFFICE OF THE ASSISTANT EXECUTIVE ENGINEER LSGD SUBDIVISION, KOZHIKKODE, GA Collage (PO), Mathara, KOZHIKKODE PIN 673014
Fire fighting works
2018_LSGD_195820_1
T5/KKD/17-18
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Olavanna
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,456
Yes
online
₹16,150
Yes
8 Oct 2020
12 Mar 2018
23 Mar 2018
12 Mar 2018
19 Mar 2018
12 Mar 2018
Amount
TERRACE PUMP
TERRACE PUMP:- Supplying, Installation, Testing and Commissioning of electric driven terrace pump suitable for automatic operation and consisting of following: complete in all respect as required.Horizontal type, centrifugal, end section pump of cast iron body & bronze impeller with stainless steel shaft, and flow of 900 lpm at 30 mtr head confirming to IS 1520.10 HP SQ cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 class of protection for enclosure, horizintal foot mounted type with Class-'F' insulation, confirming to IS-325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc.as required.
ABOVE GROUND & UNDER GROUND PIPES:- Supply, Fixing , Jointing and testing of 'C' class GI pipes of the following conforming to IS: 1239 with required attachments including necessary bends, tees, reducers, flanges, etc. The Pipes cutting. in required length and jointing with necessary bolts and nuts washers. The pipes should be given primer and two coats of red colour enamel painting and Under ground pipes should be given anticorrosive wrapping
100 mm dia
80 mm dia
25 mm dia
BUTTERFLY VALVE :- Supplying , fixing, testing and commissioning of butterfly valve PN 1.6, bronze/ Gun metal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS 13095 of following sizes as required.
100mm dia
NON RETURN VALVE :- Providing and fixing horizontal type cast iron double flanged Non -return valve of approved quality conforming to IS:5312 with bolts, nuts, washers, 3mm thick insertion rubber gaskets complete. as required
100mm dia
BALL VALVE :- SITC of Ball valve with ISI Mark
20mm dia
HYDRANT VALVE:- Supply Installation, Testing and commissioning of single headed hydrant valve conforming to IS:5290 and with ISI mark of 63/80 mm Dia oblique type with instantaneous hose coupling adapter.
HOSE CABINET:- Supplying and fixing of hose cabinet of size 600 mm x 500 mmx300 mm made of 2 mm thick MS sheet with 6 mm thick glazed glass doors i/c necessary locking arrangement suitable to accomodate 2 Nos. 15 mtr. long Hose pipe, 1No. branch pipe, mounted on wall and duly painted with Post Office red externally and white internally with synthetic enamel paint complete in all respect, for external hydrant as required.
BRANCH PIPE:- Providing and installation of Branch pipe of 63 mm dia having SS body with hexagonal head of 20mm dia nozzle conforming to IS903
HOSE REEL:-Supply, installation, testing and commissioning of hydraulic hose reel complete with swing type drum,19mm rigid hose having a length of 25 Mtrs. with stop cock and PVC / chrome plated nozzle on one end and all other necessary fixing materials.(Omex/EVERSAFE/SRI)
AIR RELEASE VALVE:- Supply, installation, testing and commissioning of Gun metal Air Release valve 20mm dia
FIRE BRIGADE INLET 3WAY: Supply, installation, testing and commissioning of 2 way Fire Brigade Inlet connection of 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arrangement to be connected to wet riser main.
PRESSURE GAUGE:- Supplying, fixing, testing and commissioning of 0-15 Kg/sq cm100mm dia Dial type pressure gauge with isolation cock and pipe at hydrant station as per specification.(Fedig/H.Guru)
PRESSURE SWITCH: Supply, installation, testing and commissioning of pressure Switch
MANUAL CALL POINT:- Supply, Installation, Testing and Commissioning of Manual call points of break glass type with hammer and chain
FIRE ALARM PANEL:- Supplying and installation Microprocessor based Main Control Panel 4 Zone, including battery charging system with all attachment for the alarm system with auto alert facilities and made MS sheet floor/wall mounting with locking arrangement duly painted as per the fire standard requirement.
HOOTER:- Supply, Installation, Testing and Commissioning of audio alarm hooters
Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
AIR CUSHION VESSEL:- SITC of air cussion vssel MS of 250mm dia with automatic air release coke 25mm dia drain valve and and a shut off and 120mm cm height
CABLE:- Supply and laying 2 x 1.5 sq.mm copper conductor PVC insulated and sheathed armoured (FRLS) fire proof cable conforming to relevant IS/Fire Protection Laws including termination complete as per specification as required.
2 core 4 sq mm with factory made clamp
CONTROL PANEL
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using 1.60 mm CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments should be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. including control wiring
Supply and providing the following size of SMC sheets in the panel as barriers & shrouding using required bolts and nuts including cutting to shape etc., as required.3mm
Supply and fixing the following types of beeding along the periphery of doors/ other detachable compartments to make the panel assembly dust & vermin proof including sticking with glue asection neoprone beeding 1.60/2.00mm
Fabrication, supply, conveyance and installation of base frame for floor mounting type panel board using channel of class designation ISMC 75 including cutting, welding, drilling holes, painting with two coats of synthetic enamel paint over a coat of zinc chromate primer, bolting the frame to the panel and to the finished floor using required bolt and nuts, making good the damages etc. as required.
Fabrication, supply & fixing main bus bar system and interconnections with electrolytic grade copper strips/ rigid conductors conforming to IS 1867 (with latest amendments) for bus bar arrangement with single strip per phase supported on finger type bus bar supports of adequate size, spacing between supports not exceeding 50 cm & overhang not exceeding 5 cm including bending to shape, drilling holes, tinning the points of contacts, fixing heat shrinkable PVC sleeves, plated bolts and nuts with plate washers and spring washers, copper sockets for round conductors, etc., as required.
Fabrication, supply & fixing earth bus system with copper strip/ conductor and connecting all accessories as per rule including g tinning the points of contacts etc as required
S & F switch disconnector unit (isolator) complete with handle assembly, door inter lock and padlocking arrangement of the following ratings:
125 A, AC 23 A, TPN SDF for DIN fuse
63 A, AC 23 A, TPN SDF for DIN fuse
2 -80A, DIN type fuse link of size 000
Supply and fixing the following accessories in the existing panel board and giving connections.
DOL starter suitable for 10HP motor
Aluminium anodised Danger Notice Board of size 200 x 150 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.
Single phase ammeter of accuracy class 1
100/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.5
Three phase volt meter (V - RY, YB, BR, R, Y, B) of accuracy class 1
LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour
SPRINKLER BULB:- Supply, installation, testing and commissioning of approved make 15mm dia brass Sprinkler heads designed to operate at 68 deg. Celsius etc. with necessery fittings etc of following type.Pendent type/ Side wall
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
4 core 25 sq mm with factory made clamp
4 core 6 sq mm with factory made clamp
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.
4 core 25 sq mm
Supplying siemens / tropodur type nickel plated Single compression brass cable gland for PVC insulated and PVC sheathed armoured aluminium/ copper conductor cable 1.1 KV grade, and making end termination suitable for 2/ 3/ 3½/ 4 core cable of the following sizes as required.
Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required.
4sqmm-16 sq mm with 12 mm wide x 1 mm thick clip
25 sq - 95sq mm with 20 mm wide x 1.20 mm thick clip
Supply of superior quality aluminium tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.
Supply and laying bare earthing conductors of the following sizes laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil).
4.00 mm copper conductor (8 SWG)
Supply and clamping the following sizes of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 x 3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1m, making good the damages, colour washing etc. as required (for Earth Bus).
25 x 3 mm copper strip tinned at the points of contacts
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required.
2.00 mm copper conductor (14 SWG)
2.65 mm copper conductor (12 SWG)
3.15 mm copper conductor (10 SWG)
4.00 mm copper conductor (8 SWG)
supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required.
3.15 mm (10 SWG)
4.00 mm (8 SWG)
Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
25 x 3mm brass bolt & nut
25 x 6 mm brass bolt & nut
Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required
2.50 cm, 4 cm or 5 cm height
Cement concrete 1:2:4 using 20mm (nominal size) broken stone for reinforced concrete work.
Brick work in cement mortar 1:6 with country burnt bricks 19cm x 9cm x 9cm for foundation and basement.
Plastering with cement mortar 1:4, 12mm thick one coat.
Colour washing, two coats
Supply and providing Fire Escape Route Chart duly framed and placed in a conspicuous location for clear vision.
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top.
Supply and providing the following sizes of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required
300 x 300 x 6 mm cast iron gully trap with covering
Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required.
2 x 25 x 3 mm GI strip
Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.
25 x 3 mm GI strip
Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with No.14 SWG bare copper , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular typeROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (For UPS Wiring)
Single control light point with 6A, 3 plate ceiling rose
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (ROHS)
3 module metal box in recess
Supply & Fixing the following types/ sizes of front plates on the existing modular boxes. (RoHS)
3 module white/ off-white
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group B)
16 A SP 1 way switch
6/16 A socket
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.
2.50 sq mm 2 run
Charges towards the preparation of necessary plan and other related papers for submission to Fire authority for getting fire NOC through panchayath (for preparing scheme & records)
Fee to be paid to fire dept. towards scrutiny & inspection (actual amount will be reimbursed on production of original documents)
Able Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_256813.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .