EE JSD Anni
EE JSD Ani
Site Development for Pump House, Const of Anchor Block 55 Nos. Laying Jointing and Testing of G.I. pipe 20mm dia 1100 Rmt. 25 mm dia 550 Rmt. 40 mm dia 2280 Rmt. for Distribution System, Providing Laying Jointing and Testing of MSERW pipe 50 mm di
2023_HPIPH_79671_1
8491-8530
Open Tender
Civil Works
Item Rate
180 days
Showad
Please refer Tender documents.
9 documents required · 9 mandatory
₹800
Yes
EE JSD Anni
₹94,947
Yes
8 Jan 2024
4 Oct 2023
10 Oct 2023
4 Oct 2023
9 Oct 2023
4 Oct 2023
Amount
Cutting in earth work and disposal of excavated earth in all kind of soil such as pick work, jumper work, blasting work in soft/ hard rock or chiseling wedging, out soft/hard rock where blasting is prohibited i/c all leads and lifts complete as per direction of Engineer-in-charge.
Excavation in foundations trenches etc. in all kind of soil in all leads and lifts such as pick work, jumper work in saturated /un saturated soil including bailing out water, blasting work in hard/soft rock or chiseling in hard/soft rock where blasting is prohibited in all leads and lifts stacking the excavated earth more than 3mtr.clear from the edge of excavation and then returning the stacked soil in 15cm.layers when required into plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and disposing of all surplus excavated earth as directed within all leads and lifts and handing over the usable materials available from excavation to department free of cost as per direction of Engineer-in-Charge within all leads and lifts.
Providing and laying cement concrete 1:3:6(1cement:3sand:6graded stone aggregate of 40mm nominal size)and curing complete excluding cost of form work including all leads and lifts: a) Foundation and Plinth.
Providing and laying cement concrete 1:4:8(1cement:4sand:8graded stone aggregate of 40mm nominal size)and curing complete excluding cost of form work including all leads and lifts: a) Foundation and Plinth.
Providing and laying cement concrete 1:5:10(1cement:5sand:10graded stone aggregate of 40mm nominal size)and curing complete excluding cost of form work including all leads and lifts: a) Foundation and Plinth.
Providing and laying cement concrete 1:1 ½ :3(1cement:1 ½ sand:3graded stone aggregate of 20mm nominal size)and curing complete excluding cost of form work and reinforcement for reinforced concrete work including all leads and lifts:
Foundation footing and bases of columns & like mass concrete.
Suspended floors, roofs, landing shelve and their supports balconies beams,girders bressumers and centilevers upto floor two level
Providing and laying cement concrete 1:2:4 ( 1cement: 2sand: 4graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work and reinforcement in:-
Suspended floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and cantilevers up to floor two levels within all leads and lifts as per direction of Engineer-in-Charge.
Providing TOR steel reinforcement for RCC work i/c bending, binding & placing in position complete up to floor two level i/c cost of binding wire (TOR steel ) in all leads and lifts as per direction of Engineer-in charge.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centering shuttering strutting and propping etc. with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4mtrs.and removal of the same for in situ reinforced concrete and plain concrete work including all leads and lifts complete to the entire satisfaction of Engineer-in-charge.
Flat surfaces such as soffits of suspended floors, roofs, landings and the like, floors etc upto 200 mm in thickness with in all leads and lifts as per direction of Engineer-in-Charge.
Veritcal surface such as wall ( any thickness) partion and the like including attached pilaster, butresses, plinth and string courses and the like with in all leads and lifts as per the direction of Engineer-in-Charge.
Foundation footing and bases of columns & like mass concrete.
Beams, Cantilevers, girders and lintels : Sides and soffits of beams, beam haunchings, cantilevers, girders , bressumers and lintels not exceeding 1 metre in depth.
Random Rubble Masonary / Polygonal rubble masonary (un- coursed brought to courses) with hard stone of approved quality in foundation and plinth including levelling up cement concrete 1:6:12 ( 1cement: 6 sand:12 aggregate )in plinth level complete in all respect within all lead and lifts as per the direction of Engineer-in-Charge.
Providing and laying cement concrete 1:5:10(1cement:5sand:10 graded stone aggregate of 40mm nominal size) with 15% plum and curing complete excluding cost of form work in retaining walls/breast walls, the size of plums shall usually be 150mm to 300mm as per H.P.P.W.D specification including all leads and lifts complete to the entire satisfaction of Engineer-in-charge.
Brick work using common burnt clay building bricks in foundation and plinth in cement mortor 1:6 (1 cement: 6 sand), 1st class bricks complete in all respect with in all leads and lifts.
Brick work using common burnt clay building bricks in super structure above plinth level up to 1st floor level in cement mortor 1:4 (1 cement: 4 sand), Ist class bricks complete in all respect with in all leads and lifts.
Half brick work using common burnt clay building bricks in super structure above plinth upto 1st floor level in cement mortar 1:3 ( 1Cement, 3 Sand ) of 1st class bricks complete in all respect with in all leads and lifts.
Pointing on brick work with cement mortar 1:3 (1 cement,3 sand) with in all leads and lifts complete in all respect Raised and cut.
Providing and laying brick tiles over mumty roofs grouted with cement mortar 1:3 over a 12mm layer of cement mortar 1:3 and finished needly within all leads and lifts and as directed by the Engineer-in-charge.
Providing wood work in frames of doors,windows,clerestory,windows and other frames wrought,framed and fixed in position. Complete within all respect. 2nd class teak wood.
Providing and fixing panelled glazed or panelled and glazed shutters for doors, windows and clerestory windows i/c bright finished black enamelled iron butt hinges with necessary screws 40mm thick 2nd class teak wood with in all leads and lifts as per direction and to the entire satisfaction of the Engineer-in-charge.
Providing and fixing wire gauge shutters using galvanised M.S. wire gauge of IS gauge specification 8 S.G with wire of dia 0.56 mm for doors,windows ic bright finished black enamelled iron butt hinges with necessary screws 30 mm thick of 2nd class teak wood with in all leads and lifts complete in all respect.
6 mm thick cement plaster in CM 1:3 (1 cement :3 sand in roof slabs.with in all leads and lifts as per direction and to the entire satisfaction of the Engineer-in-charge.
15 mm thick cement plaster in single coat on rough side of brickstoneconcrete walls for interior plastering up to floor two level including arrisses,internal rounded angles,chamfers and or rounded angles not exceeding 80 mm in girth and finished even and smooth with in all leads and lifts in C.M 1:6 ( 1 cement,6 sand ) with in all leads and lifts as per direction and to the entire satisfaction of the Engineer-in-charge.
20 mm thick cement plaster on rough sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:4 (1cement:4sand) with in all leads and lifts as per direction and to the entire satisfaction of the Engineer-in-charge.
White washing with lime on undecorated wall surfaces(two coats) to give an even shade I/c thoroughly brooming the surface to remove all dust dirt & other foreign matter as per direction & to the entire satisfaction of Engineer-in- Charge upto all lead & lifts.
Distempering with dry distemper of approved brand and manufacturer ( Two Coats ) and of required shade on un-decorated wall surfaces to give an even shade over and including priming coat of whiting after throughly brushing the surface free from mortar and other foreign matters with in all leads and lifts complete in all respect.
Finishing wall with water profing cement paint of approved brand and manufacture and of rerquired shade on undecorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials. with distemper primeras per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.
Applying priming coat on new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil,greese,dirt and other foreign matters,sand papering and knotting.Ready mixed paint brushing wood primer pink. as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.
Painting two coats(excluding coat) on new wood and wood based surface with enamel paint to give an even shade including cleaning the surface of dirt,dust and other foreign matter,sand papering & stoping with enamel paint other then white and as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.
Cement concrete flooring 1:2:4 (1cement :2sand 4graded stone aggregate 20mm nominal size ) laid in one layer finished with a floating coat of neat cement 40mm thick with in all leads and lifts as per the direction of Engineer-in-Charge.
Providing and fixing anodized Mild Steel sliding door bolts withnuts and screws complete I) 300mmX16mm
Providing and fixing anodized mild steel. tower bolts barrel type with screws etc. complete.
200mmX10mm
Providing and fixing anodized mild steel handles with screws etc. complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS:15622 of approved make in all colours and shades, laid on 20 mm thick cement mortor 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigment etc. complete in all respect.
Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement: 3sand: 6graded stone agg. 20mm nominal size) i/c finishing the top surface of concrete smooth within all leads and lifts and as directed by the Engineer-in-charge.
Providing 40x3 mm flat iron hold fast 40cm. Long including fixing to frame with 10mm dia metres bolts, nuts and wooden plug and embedding in cement concrete block 30x10x15cm. 1:3:6( 1cement:3sand:6 graded stone att. 20mm nominal size) within all leads and lifts and as directed by the Engineer-in-charge.
Laying , Jointing and Testing of GMS pipes screwed and socketed in trenches to required grades as per IS: 1239 latest with up to date amendments of following dia and class of pipes i/c all fittings and accessories etc. complete in all respect. (Earth work in trenches to be measured and paid for seperately).(Distribution System) (LR)
20 mm dia (LC)
25 mm dia (LC)
40 mm dia (MC)
Providing laying, jointing (by way of circumfrential butt welded joints by electrical arc welding) and testing of MSERW pipe of following dia meters confirming to BIS 3183-2007 confirming to X-42 pipe of following diameter (latest with up to date amendments) steel grade A & wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers, all short pieces, beds etc. as per site requirement made from parent tubes. The laying of pipe will include all operation such as cutting. welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
RD From To Length in mtrs Pipe (MM) wall Thickness Class 0 to 1800 = 1800 50 4.80 (X-42 ) 100% Length of Butt Welding = 1800 rmt.
Laying and binding (By way of circumferental butt welding by electrical arc welding) and testing of galvanised mild steel tube G.I pipe of following dia. Confirming to BIS 1239-2001 (Latest with upto date ammendements having wall thickness as per code with bevelled / Plain ends in a random length of 4 to 7 Mtrs. including mfg. reducers/ tapers all the pieces, bends etc. as per site requirement made from parent tube. The laying of will includes all operation such as Cutting, welding, jointing, fabrication of bends, tee etc. including lowering and laying in excavated trenches to ensure required level including flushing and cleaning anad hydrullic testing complete in all respectto the satisfaction of the Engineer in Charge. the fabricated bend shall have three or four cuts having its radius not less than five times the dia. of ppe. the dameged portion of the pipe end special made form the parent tube during welding or otherwised shall be provided anti corrossive treatment by applying two coats of anti corrossive bitumens paint over a priming coat as per AWWA specifications C-203 -1978. the welding electric shall be Aas per IS 814 of advani Oerlkon / L&T or ISI markd make. The rate also includes entire carriage of material, flushing, cleaning, hydraullic testing complete to the best satisfication and direction of Enginner in Charge with in alll leads and lifts.(Earth work in trenches will be measured and paid for separtely. (LR)
RD From To Length in mtrs Pipe (MM) wall Thickness Class 1800 to 3000 = 1200 50 4.50 HC 100% Length of Butt Welding = 1200 rmt.
RD From To Length in mtrs Pipe (MM) wall Thickness Class 3000 to 3300 = 300 50 3.60 MC 100% Length of Butt Welding = 300 rmt.
"PUMPING MACHINARY:- Supply, erection & commissioning of horizontal spindle,horizontal split casing radial split single multi stage centrifugal pump or combination of pumps, In senes/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyob or any other make approved from JSV Department as per BIS 1520-1980 with upto date ammendments, read with IS 9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze impellers/priming funnels casing ring and shaft sleeves of bronze shaft of steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor existing of standard make such as Kirlosker/Crompton/BHEL /NGEF/GEC/Siemens/Jyoti /ABB or any other make approved from JSV deptt. suitable for operation on 415(+/-)10% volts,50 cycles /second 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-)15% of the duty point head. The motor/motors confimiing to minimum IE2 norms IS-12615/2011 with upto date ammendments. It should include cost of bearing nuts, bolts and painting etc and should meet the following requirements.
I) Discharge (Q) 1.55 LPS for each pump
II) Total dynamic head 650.84 Mtr.
a) LWL in sump well (h) 2762 Mtr.
b) Shaft level 2760 Mtr.
c) Level at discharge point 3310 Mtr.
d) Suction lift +Ve
e) Dischrage head 550 Mtr.
f) Static head 550 Mtr.
III) Rising main
a) Length 3300 Mtr.
b) dia 50 MM
iv) Pumping hours 8 Hours
v) altitude of installation above MSL 2760 mtrs.
vi) Characterstics of water. Clear water with Turbidity upto 50PPM
a) Temperature 20 Degree centigrade
b) ambient temp. 44 Degree centigrade
c) Turbidity 50 JTU
d) Alkalanity mg/1ca
e) Size of the solids mm
Note: One Pump set working & One stand by
Providing and fixing ICTP main switch with HRC fuses of Kilburn/L&T/Seimen/ Standred/Havells make and having capacity 30% extra of the operationl rating/ as per IS-4064-1978 with up to date ammendments immediately after the power meter of the HPSEB.
Providing & fixing M.S. sheet,steel fabricated floor mounted closed (almirach type switch board including angle iron post of suitable height and size ISA 40x40x6, duly painted with steel sheet of 16 guage comprising and capable of mounting the following accessories with all internal connections.All accessories should be suitable for the proposed pumping machinery at item NO.38 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authoroties.
OCB/MCCB of MEI/Havels/standard make and suitable capacity of offered motor on incoming feeder with or without intial oil filling as the case may be with linked under voltage released as per relevent IS code with up to date ammendments.
Earth leakage circuit breaker ELR of recommended make(Kilburn/L&T/MEI/GEC as per IS:2516-1977 with uptodate ammendements and of suitable of range which should have control box, operating,handle and trip/reset bush button on/off indicatorsre-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape CTS, It should also be fitted with earth fault for tripping of breaker on occurance of earth fault on off breaker load side and.suitable for 60 HP motor.
The voltage meter relay of AE/MEI/L&T/ Havells make 3 phase with all protection and usual indicators and electric siran against single phasing, Low voltage high voltage reverse phasing over loading and phase voltage difference as per IS:3842(latest edition)
Digital 100 mm diameter circular dial A.C. supply volt meter of recommended make AE/IMP/Havells of suitable range with slector switches as per IS:4064-1978 with uptodate ammendements.
Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with up to date ammendments
Digital frquency meter of standard make AE/L&T/IMP/Havells as per relevant IS code with up to date ammendments
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for netural phase as per IS:8084-1976 and IS:11353-1985 read with BIS-5578-1985 with uptodate ammendements.
Providing ICTP change over switches with HRC fuses unit of Kilburn/L&T /Siemens/Standarrd/Havells make and of suitable capacity as per IS:4069-1978 with up to date amendments.
Three phase indicator lamps complete with toggie switches for individual motors as per IS:3452(P-I&II) with upto date ammendements.
Capacitor of Mecheil/BHEL/GEC/L&T/ make as per IS 2834-1986 with upto date ammendements, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code (of Siemens/Clocter/IEC make) from bus bar chamber to capacitor and also including ICPT switches of appropriate upto date ammendements.
Providing fixing suitable oil imersed Auto transformer/starter rotor starter of MEI/Kilburn/Jyoti /L&T/ Siemens/make as per IS:8544-1979 with upto date ammendements for squirrel cage/slip ring motor mounted on panel board with magentic type over load release and dashpot,time lag,under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS:1248(P-V)-1983 with upto date ammendements.
Providing Digital hour run meter of recommended make and suitables capacity as per IS :722 ( latest edition)
Providing antivibration pads under the pump and motor of suitable size for the above pumping machinery as per IS: 6337: 1971.
Providing double flanged CI sluice valve PN-1.6 of Leader/BHEL/Kirlosker/ GLED/Kilburn /Fourses / Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments.
Providing double flanged Cast steel sluice valve ASA 600 of Leader/BHEL/Kirlosker/ GLED/ Kilburn /Fourses make and one step higher then delivery line of pump and capable of withstanding the normal seat pressure as per BIS standards with upto date ammendments.
Providing double flanged swing type Cast Steel valve ASA 600 of Leader/BHEL/Kirlosker/ GLED/ Kilburn /Fourses make and having bye pass arrangement of one step higher then delivery line of pump and capable of withstanding the normal seat pressure as per BIS standards with upto date ammendments.
Providing double flanged Cast Steel reflux valve ASA 600 of Leader/BHEL/Kirlosker/ GLED/ Kilburn /Fourses make and of 50 mm dia having bye pass arrangement for rising main and capable of withstanding the normal seat pressure as per BIS standards with upto date ammendments.
Providing 100 mm dia circular dial analog pressure gauge of suitable range of Fiebig/Bourden/PREGA/Precision make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with upto date ammendments.
Providing of discharge meter of standred make to be fixed on the rising main in pump house as per the direction of the Engineer-in-Charge as per IS 2373-1981with upto date ammendments
Installation of all the items apparing at serial No. 39 to 60 as per the systematic.
Providing and fixing double flanged MS/GI piping work(layout to be approved by the Engineer-in-charge work for suction and delivery pipe suitable of pump(S) offered and common header as per the Rising main respectively complete with all specials such as bends Rising main respectively complete with all specials such as bends tees, reducers, increasers,with companion flanges matching with the IS specification of the accessories including rubber/ asbostos gasket of 3mm thickness as per IS 2712-1979 and required number of nuts and bolts as per IS 1364-1983. The pipe shall be as per relevent IS code and to with stand 1.5 times total head stipulated under item No.1. The size of the various component to be as under:-
Suction pipe: One dia higher then the suction of the pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe.
Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe.
Common headere: One dia higher then delivery of pump 50 mm dia and will extend upto 5 meter from the outer wall of the pump house in direction to be jointed.
Providing and laying copper PVC insulated armured power cable (one cable carrying all the three phases) of 3 core suitable size and capacity to motors and all other electrical equipments as per IS: 1554(P-I) 1988 or latest with upto date ammendements of siemens/Gloster/IEC/ICC/EICO/ National/ GRANDLY make including all other accessories such as thimble, flaxible pipes, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. (Motor side & Supply side).
Motor side (From switch to starter and starter to motor) of suitable size & requirement of HPSEBL authority.
Supply side (From Meter of HPSEB to bus bar and switch) of suitable size & requirement of HPSEBL authority.
Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
SANITARY FITTINGS:- Providing and fixing to wall ceiling and floor galvanised mild steel tubes ( MG) including fitting and clamps including making good the wall ceiling and floor complete in all respect in all leads and lifts and to the entire satisfaction of Engineer-in-charge ..
15mm nominal size
Providing and placing (at all heights) polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes including all fittings and float valve excluding the base support for tank [Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license ]. 500 Ltrs. capacity
Providing and fixing vitreous china wash, down water closet (European type. W.C. pan) with integral 'P' or 'S' trap including jointing the trap with soil pipe in cement mortar 1:1 (1 cement: 1 sand). Seat and cover to be measured and paid for seperately. Anglo Indian Universal closet.
Providing and fixing plastic seat and cover for wash down water closet with C.P. brass hinges and rubber buffers: White plastic seat and cover, solid type.
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White
Providing and fixing PVC / G.I. inlet connection for flush pipe connecting with W.C. pan.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
Providing and fixing C.P. brass angle valve of standard design and of approved make, 15mm nominal bore.
Providing and fixing C.P. water jet including connection pipe with check nut complete in all respect.
Providing and fixing PVC pipes of 10 Kg f/Sq.cm working pressure including fittings as per requirement at site complete in all respect in all leads and lifts and to the entire satisfaction of Engineer-in-charge .110 mm OD
ELECTRICAL FITTINGS:- Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. complete with in all lead & lifts and to the entire satisfaction of the Engineer-in-Charge. (Group C)
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. complete with in all lead & lifts and to the entire satisfaction of the Engineer-in-Charge.
2x1.5 Sq.mm
2x4.0 Sq.mm
(a)Supplying and fixing following rating Piano-type switch /socket on the existing switch box / cover including connections etc. as required. Switch S.P 5/6 amps.
(b)Supplying and fixing following rating Piano-type switch /socket on the existing switch box / cover including connections etc. Socket 5 pin 5/6 amps.
(a)Supplying and fixing following rating Piano-type switch /socket on the existing switch box / cover including connections etc. as required S.P. 15/16 Amps socket outlet.
(b)Supplying and fixing following rating Piano-type switch /socket on the existing switch box / cover including connections etc. as required. 6 pin 15/16 Amps socket outlet.
Supplying & fixing wooden boxes of following sizes (nominal size) on surface or in recess suitable for fixing phenolic laminated sheet cover in front including painting etc. as required:-
229mm.x102mm.x60mm. deep
203mm.x152mm.x60mm. deep
Supplying and fixing ceiling rose on the existing junction box /wooden block including connections etc. as required.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps. Cat-A.
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:-
Providing and fixing ultra slim decorative extruded box fixture with domestic electronic ballast, snap-on installers, suitable for 28 watt FTL (T5), complete with all accessories (including one No. T-5 Tube), connections, testing and commissioning etc. as required.
1 x28 watt-FTL(T5) (Category-A)
Providing and fixing following type of surface mounting decorative mirror optics luminaire with powder coated CRCA sheet steel housing, low glare aluminium mirror reflector, prewired with 110 V starter & 36/40 w copper ballast for housing CFL (but excluding the cost of CFL), complete with all accessories, connections, testing and commissioning etc. as required.
1.4 2604 3 x36 watt-CFL (Category-A)
Providing and fixing two core service wire 6mm thick.
Jai Chand Rana
Raman Thakur Govt. Cont.
CHAUDHARY RAM GOVT CONT
BHAGWAN DASS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .