| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC RZ 140 A EAST SAGARPUR STREET NO 7 8 NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Acceptance of contract | |
| 2 | L2₹39.9 L+₹8.1 L (25.3%)Rejected-AOC H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L2 | Rejected-AOC R | |
| 3 | L3₹40.9 L+₹9.0 L (28.3%)Rejected-AOC 181 2 KHURBURA MOHHALLA DEHRADUN UTTARAKHAND 248001 UDYAM UK 05 0028406 | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC R | |
| 4 | L4₹41.6 L+₹9.8 L (30.8%)Rejected-AOC | L4 | Rejected-AOC R | |
| 5 | L5₹43.9 L+₹12.0 L (37.7%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L5 | Rejected-AOC R |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE IMA Dehradun
GE IMA Dehradun
PETTY REPAIR AND MAINTENANCE OF ELECTRIC SUPPLY OF MD AND OTM ACCN AT NORTH COMPLEX AT IMA DEHRADUN
2023_MES_633526_1
GE/IMA/T-69 of 2023-2024 9372/E8
Open Tender
Support/Maintenance Service
Item Rate
334 days
GE IMA Dehradun
Refer NIT
8 documents required · 8 mandatory
₹500
Yes
GE IMA Dehradun
₹90,000
Yes
8 Feb 2024
19 Dec 2023
18 Jan 2024
20 Dec 2023
16 Jan 2024
2 Jan 2024
Amount
M&L for attending no supply in the blocks/qtrs/lines/offices in the OTM/Md Accn due to any reason like MCBs/MCCBs burnt out/tripping, leakage fault, short/open circuit faults, electric fittings/fixtures, all type of controls, controls of garden/street lights,controls of summer and cooling appliances i.e Fan , Exhaust Fan , Wall Fan ,Geyser etc.with rectification and restoring the supply by trained person complete all as specified and directed of following areas:-
North complex OTM/Md Accn Area (Tones View,Polo View,Golf View,Golf Course, OffIcers Mess , C Cell E/M,C Cell B/R ,Asiana,AGR, P-1 TO P-19,Gate No-6 ,VEG Shope,NIZAM, ACC Office , Poorvi Gate ,Mech Line ,Triangle Line ,CHETWOOD,QM , North Gate,CSD,Cafeteria,COLLINS Blk,Kingsley Blk,Account Sec , Printing Press Drill Grounf /Office Hoshiyar Singh Gym, Tele Exch,Qtr Guard ,Civil Establishment,DSC Guard Room , Mandir POst ,TA BN ,DSC,Raman Hostle,Section Hospital,Acadmic Block,Band Line,SBI,Gass Godwon,Post Office,UA Office,CLK Welfare Center,Pumps house) (Approximate area 4 Km )
CR camp (Md Accn),GE Office and Subdivn,WT Area,GD Platoon, DEMO-I,DEMO-II, JCO Mess,JCO Living ,ACC Mess Area,WT Area,STAND –I,STAND –II,Helipad Area,Bamboo Post,Kali Mandir,Old ACC Building,Pumps house and Guard Post) (Approximate 4 Km )
Note: All the T&P items like aluminium folding self supported ladders as per site requirement, drill machines with bits, cutting plier, spanners, Allen key Set, Pipe wrench, Screw driver Sets, Crimping tool,descaling rod & communication system to the trades man etc will be provided to electricians by the contractor. The cost of T&P shall be inciuded in quoted rates and no extra cost will be paid by department. Tool Bags required for attending the complaint shall also be provided by contractor to the tradesmen.
All the stationery i.e complaint register, job card dockets and other connected register related to the work shall be arranged and to be maintained by the contractor.
Stores required for day to day maintenance for all repair work provided by the contractor through this contract as supply & fix. All sundries items like Insulation Tape, Screws, washers, Plastic wall rawal plugs,Nuts, Bolts, dummy plates, thimbles for coper/Alluminium cable/ wire ,Flexible pipe , Clamp and mounting bracket for lights etc shall be supplied/ arranged by the contractor without any extra cost to Govt.
All the retrieved material shall be the property of Contractor with Sch of credit as shown on credit schedule.
Contractors are advised to visit the site before quoting rates.
Contractor shall be penalised @ Rs. 200/- per complaint/ day, if he fails to attend and rectify the complaint within 24 hours of lodging the complaint either personally or telephonically. In this regard the decision of the Engr-in-Charge shall be final & binding.
The employed electrician should have minimum 03 years experience concerned trade.
Work shall be carried out as per modern engineering practice and contractor to maintain record register, duty roster, attendance register etc complete alongwith general tool safety measures on conveyance/ transportation uniform etc.
Conractor also provide the almirah to the electricition employed under the contract to keep their tool bags /stationary etc in safe custody.
Supply and fixing in repairs the following Item No 3 to 112 :- Note : The contractor has the responsibility to make good the existing surfcace after repair work. (iii) The contractor has resposibility for site clearance after carrying out the wk at site. (iv) If the contractor fails to make good the distrubed surface /site clearance recovery for an amount of Rs. 5000.00 be made from every RAR.
Distribution boards epoxy powder coated TP & N (VTPN MCCB DB) 4 Way
Distribution boards epoxy powder coated TP & N (VTPN MCCB DB) 8 WAY
MCCB ,4 pole ICS=100% ICU at 415 volts with rupturing capacity 16 KA with thermal-magnetic release and adjustable overload setting of capacity 100 Amps
MCCB ,4 pole ICS=100% ICU at 415 volts with rupturing capacity 16 KA with thermal-magnetic release and adjustable overload setting of capacity 125 Amps
MCCB ,4 pole ICS=100% ICU at 415 volts with rupturing capacity 16 KA with thermal-magnetic release and adjustable overload setting of capacity160 Amps
MCCB ,4 pole ICS=100% ICU at 415 volts with rupturing capacity 16 KA with thermal-magnetic release and adjustable overload setting of capacity 200 Amps
MCCB ,4 pole ICS=100% ICU at 415 volts with rupturing capacity 16 KA with thermal-magnetic release and adjustable overload setting of capacity 250 Amps
MCB SP 6 to 32 Amp.240 volts B curve.
MCB SP 40 to 63 AMPS 240 volts B curve.
MCB SPN 6 to 32 Amps 240 volts B curve.
MCB SPN 40 to 63 Amps 240 volts B curve.
MCB DB 4 way SPN DB.
MCB DB 8 way SPN DB.
MCB DB 12way SPN DB
MCB DB 16 way SPN DB.
Sheet metal enclosure, single pole and neutral with two pin and earth plug and socket with and including one single pole MCB 20 Amps.
Fan regulator modular step type 100W 240 volts 2 module.
Modular switch single pole one way 6 Amp .
Modular switch single pole one way 16 Amp .
Modular socket outlet 2/3 pin combined 6 Amp 240 volts .
Modular socket outlet 2/3 pin combined 16 Amp 240 volts.
Modular bell push flush type, 5 Amps including taking down old unsv bell push .
Bell push flush type, 5 Amps .
Modular cover plate with frame 1Module
Modular cover plate with frame 2Module
Modular cover plate with frame 3Module
Modular cover plate with frame 4Module
Modular cover plate with frame 6Module
Modular cover plate with frame 8 Module
Modular metal flush box 1Module
Modular metal flush box 2Module
Modular metal flush box 3Module
Modular metal flush box 4Module
Modular metal flush box 6Module
Modular metal flush box 8 Module
Bell AC 230 volts single pole .
Ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate/isolated body
Electronic steppped type fan regulator 100 watt 230 volts AC 50 Hz .
Batten holder, PVC/polycarbonate type with back plate suitable for batten fittings .
Switch piano, flush type, single pole one way 6 Amp .
Switch piano, flush type, single pole one way 16Amp
Socket out let, multipurpose, 2 in 1 5 pin, 6 Amp
Socket out let, multipurpose, 2 in 1 5 pin, 16 Amp with fuse and neon indicator.
Electronic dimmer type fan regulator 100 watt 230 volts AC 50 Hz
Industrial hanging bed switch 5/6 Amps ,230 Volts.
Bakelite sheet cover 3 mm thick 125 x125 mm.
Bakelite sheet cover 3 mm thick 200X125 mm.
Bakelite sheet cover 3 mm thick 250X300 mm.
Single phase electronic meter temper proof LCD display with polycarbonted cover 230volt ,10 A to 60 Amps ,accuracy class-I 50 Hz ,confirming to IS 13779,ip-54 with parameter to show data time ,current reading ,load PF ,voltage and KWH.
Three Phase electronic meter temper proof LCD display with polycarbonted cover 415 volt ,10 A to 60 Amps ,accuracy class-I, 50 Hz ,confirming to IS 13779,IP-54 with parameter to show data time ,current reading ,load PF ,voltage and KWH . MAKE : L&T/HPL/SECURE
Flexible cable 3 core 23/0.0076 multi stranded copper conductor white/ black colour code
Exhaust fan 250 mm sweep, 1200 RPM, ,made up of Sturdy Engineering Plastic complete ,voltage 230 Volts ,50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, box type louvers. Make : Crompton/ orient/ Khaitan/Usha
Single core FR-LSH PVC insulated copper multi stranded conductor cable1.5 sq mm.
Single core FR-LSH PVC insulated copper multi stranded conductor cable2.5 sq mm.
Single core FR-LSH PVC insulated copper multi stranded conductor cable4 sq mm
Single core FR-LSH PVC insulated copper multi stranded conductor cable6 sq mm.
Single core FR-LSH PVC insulated copper multi stranded conductor cable10 sq mm.
pressed steel sunken terminal boxes 1.6 mm thick, 60 mm 125 x125 mm.
pressed steel sunken terminal boxes 1.6 mm thick, 60 mm 200X125 mm.
pressed steel sunken terminal boxes 1.6 mm thick, 60 mm 250X300 mm.
Rigid non metalic PVC conduit of 40mm dia with all accessories
Rigid non metalic PVC conduit of 32mm dia with all accessories
Rigid non metalic PVC conduit of 25mm dia with all accessories
Rigid non metalic PVC conduit of 20mm dia with all accessories
PVC rectangular block white in colour 100mmx100mm and 50mm deep
PVC rectangular block white in colour175mmx100mm and 50mm deep
PVC Casing Caping 50X20 mm dia
PVC Casing Caping 38 X 20mm dia
PVC Casing Caping 32X 16 mm dia
PVC Casing Caping 25 X 16 mm dia
Bulb LED 2.7 W, E-27 base,220v- 240v ,50 HZ .
Bulb LED 3 W, E-27,220v- 240v ,50 HZ base.
Bulb LED 5 W, E-14 base, 220v- 240v ,50 HZ .
Bulb LED 9 W, E-27 base,220v- 240v ,50 HZ
Energy saving LED Bulb 14 W, E-27 base,220v- 240v ,50 HZ.
Bulb LED 5 W,MR-16,GU5.3 base,220v- 240v ,50 HZ .
Exhaust fan 200 mm sweep, 1200 RPM, ,made up of Sturdy Engineering Plastic complete ,voltage 230 Volts ,50 Hz, energy saving model single phase copper wound motor, white in colour Make : Bajaj/ Orient/ Crompton
Wall mounted Fan plastic body 400mm sweep ,2100 RPM high speed and 105CMM Air Delivery,strudy base and thermal overload protection ,voltage 230 Volts ,50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade. Make : BAJAJ/HAVELLS /Crompton
LED batten light fitting 4 feet of lumens 2500 lumens, wall mounted ,high pressure die cast alluminium, fully diffused ,system efficacy 125L/W . Make : Havells/Philips /Crompton
LED batten light fitting 2 feet of 1000 lumens wall mounted ,high pressure die cast alluminium, fully diffused ,system efficacy 100L/W.
LED Suspended Batten light fitting 4 feet of lumens 4000 lumens wall /Surface mounted ,high pressure die cast alluminium, fully diffused ,system efficacy 100 L/W complete all as specified and directed. Make : Havells/Philips /Crompton
LED Up Down twin glow 20W + 20W light fitting of lumens 2000 lumens wall mounted ,high pressure die cast alluminium, fully diffused ,polycarbonated diffuser,system efficacy 100L/W complete all as specified and directed.
LED 1 x 1 feet Surface/recess mounted light fitting of lumens 1800 lumens ,CRCA housing, fully diffused ,polycarbonated diffuser, ,system efficacy 100L/W complete all as specified and directed.
LED street/Security wall mounted light fitting of lumens 2500 lm ,Single Piece High pressure die cast aluminium,system efficacy 100L/W complete all as specified and directed.
LED 2 x2 feet Surface/recess mounted light fitting of lumens 3600 lumens ,CRCA housing,Polycarbonated Cover for More protection , fully diffused ,system efficacy 100L/W complete all as specified and directed.
LED Round/Square ,Surface /Recess mounted light fitting of lumens 1800 lumens ,Single Piece body Die cast lluminium ,System efficacy 100 Lm/Watt complete all as specified and directed.
LED Round/Square ,Surface /Recess mounted light fitting of lumens 1500 lumens, Single Piece body Die cast lluminium ,System efficacy 100 Lm/Wattcomplete all as specified and directed.
LED bulk head fitting wall mounted fitting of lumens 1000 lumens ,Single Piece body Die cast lluminium ,System efficacy 100 Lm/Watt complete all as specified and directed.
LED flood light fitting wall mounted fitting of lumens 5000 lumens ,Single Piece body Die cast lluminium ,System efficacy 100 Lm/Watt , complete all as specified and directed.
LED inverter bulb 9 watt retrofit type works on AC Normal mode and DC supply in inverter mode with inbuilt battery back up of up to 4 hours, high efficiency high lumens output , complete all as specified and directed. Make: Make : Havells/Philips /Crompton
Metal finished bed side lamp grey in colour 20 Watt /50 Lumens/3000K, base of the lamp should be E27 and dimension of fitting 470x67x28 mmacomplete all as specified and directed.
Metal finish wall light with maximum bulb wattage 12 watt, base of the lamp should be E27, colour of the fixture is white & silver wsith chrome finish and having rectanguar shape for aesthetic look. dimension of the fixture should be 100 x 125 x 200 mm complete all as specified and directed.
MCB TPN complying to IS/IEC 60898, 240 volts 'C' Curve 10 KA, 63 Amps, 415 volts.
MCB TPN complying to IS/IEC 60898, 240 volts 'C' Curve 10 KAMCB TPN 100 Amps, 415 volts Make :
Heating Element 2 KW 230 volt,round /triangular /square/rectangular type
Heating Element 3 KW, 230 volts ISI markded Round shape base .
Thermostat switch 220- 240 volt 16 Amp 0-75° /80° C ISI marked as per sample suitable for round complete all as specified and as directed. Make-Newton/Theta/Dashmesh.
Indicating lamp 230 volt AC for geyser of Green & Red colourcomplete all as specified and as directed.
Heavy duty PVC connection with 15mm dia 450mm long with CP brass nuts and leads PVC washer 02 Nos on each ends for geyser connection complete all as specified and as directed.
Heavy duty PVC connection with 15mm dia 600mm long with CP brass nuts and leads PVC washer 02 Nos on each ends for geyser connection complete all as specified and as directed.
Metal clad Industrial plug top ISI mark, 3 pin with earth, 230 to 250 Volts all as specified and as directed.
Multifunction safety valve cast copper alloy 15 mm dia ISI marked complete all as specified and as directed.
3 Pin plug top 15 amps complete complete all as specified and as directed.
Stainless steel chromium plated assembly ISI marked as per sample suitable for water heater of capacity 25/35 ltrs complete all as specified and as directed.
Stainless steel chromium plated assembly as per sample suitable for water heater of capacity 50 ltrs complete all as specified and as directed.
Louvers for exhaust fan of 450mm sweep complete all as specified and directed
Louvers for exhaust fan of 300mm sweepl complete all as specified and directed
Ceiling Fan Capacitor 2.5 Mfd
Ceiling Fan Capacitor 3.15 Mfd
MS clamps with 40mmx4mm thick flat iron bent to shape any type having center two holes, nuts & bolts for hanging Fans complete fixed in repair complete all as specified and directed
PARADISE INFRA POWER COMPANY
ANAND SERVICES
Balraj and Co
JS CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .