Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC DHOBI MOHALLA BATMALOO SRINAGAR 190010 J K | SRINAGAR | SRINAGAR | J K | 190010 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹15.4 L+₹1.2 L (8.21%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹18.3 L+₹4.0 L (28.4%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹19.1 L+₹4.8 L (34.0%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹19.8 L+₹5.5 L (38.9%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
14 Jan 2021, 6:00 pmClosed
GE 969 EWS
GE 969 EWS C o 56 APO
REPAIR/MAINT OF DG SETS, SUMMER APPLIANCE AND VOLTAGE STABLIZER OF VERIOUS CAPACITY AT PATTAN AND BARAMULLA UNDER GE 969 EWS
2020_MES_405030_1
CANO 969/WS- /2020-21
Open Tender
Civil Works
Item Rate
180 days
Baramulla
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹40,000
Yes
31 Mar 2021
19 Dec 2020
16 Jan 2021
19 Dec 2020
14 Jan 2021
2 Jan 2021
Amount
Servising of Diesel engine Generating sets 15 KVA to 25 KVA Rating to be carried out as per schedule given as under. B - check :- (Every 100 Hrs or 6 months whichever is earlier) (i)Change lubricating oil (ii) Change lubricating oil filters (iii)Change fuel filters(iv) Change coolant (v)check Engine wiring for damage (vi)Drain fuel supply tank (vii) Change by pass lubricant filters (viii) Change air filters (ix) Check oil pressure (x)Change fuel water seperator. C - Check :- (Every 1500 Hrs or 1 year whichever is earlier) (i) Adjust valves (ii)Steam clean engine (iii)Replace hoses if required (iv) Check turbo charger mounting nuts (v )cCheck engine oil heater (vi) clean rediator (vii) Inspect following parts and replace if required (i.e Alternator,starter etc ) (viii)Clean fuel from inside (ix) Change engine oil. Note :(i) B-check and C check spare parts will be measured and paid separately under supply only items (fixing charges included with the servicing of DG set.) Complete all as specified and directed by Eng-In-Charge.
Servising of Diesel engine Generating sets 30 KVA to 63 KVA Rating to be carried out as per schedule given as under. B - check :- (Every 100 Hrs or 6 months whichever is earlier) (i)Change lubricating oil (ii) change lubricating oil filters (iii)change fuel filters(iv) Change coolant (v)check Engine wiring for damage (vi)Drain fuel supply tank (vii) Change by pass lubricant filters (viii) Change air filters (ix) Check oil pressure (x)Change fuel water seperator. C - Check :- (Every 1500 Hrs or 1 year whichever is earlier) (i) Adjust valves (ii)Steam clean engine (iii)Replace hoses if required (iv) Check turbo charger mounting nuts (v )cCheck engine oil heater (vi) clean rediator (vii) Inspect following parts and replace if required (Alternator,starter etc ) (viii)Clean fuel from inside (ix) Change engine oil. Note :(i) B-check and C check spare parts will be measured and paid separately under supply only items (fixing charges included with the servicing of DG set.) Complete all as specified and directed by Eng-In-Charge.
Servising of Diesel engine Generating sets 63 KVA to 160 KVA Rating to be carried out as per schedule given as under. B - check :- (Every 100 Hrs or 6 months whichever is earlier) (i)Change lubricating oil (ii) change lubricating oil filters (iii)change fuel filters(iv) Change coolant (v)check Engine wiring for damage (vi)Drain fuel supply tank (vii) Change by pass lubricant filters (viii) Change air filters (ix) Check oil pressure (x)Change fuel water seperator. C - Check :- (Every 1500 Hrs or 1 year whichever is earlier) (i) Adjust valves (ii)Steam clean engine (iii)Replace hoses if required (iv) Check turbo charger mounting nuts (v )cCheck engine oil heater (vi) clean rediator (vii) Inspect following parts and replace if required (Alternator,starter etc ) (viii)Clean fuel from inside (ix) Change engine oil. Note :(i) B-check and C check spare parts will be measured and paid separately under supply only items (fixing charges included with the servicing of DG set.) Complete all as specified and directed by Eng-In-Charge.
Supply and fixing new air filters cartridge elements with 'O' ring for 15 to 25 KVA DG set. Complete all as specified and directed by Eng-In-Charge.(Make : Kirlosker /cummins/ fleetguard)
Supply and fixing new air filters cartridge elements with 'O' ring for 30 to 63 KVA DG set. Complete all as specified and directed by Eng-In-Charge.(Make : Kirlosker/cummins /fleetguard)
Supply and fixing new air filters cartridge elements with 'O' ring for 63 to 160 KVA DG set. Complete all as specified and directed by Eng-In-Charge.(Make : Kirlosker/cummins/ fleetguard)
Supply only fuel oil filter cartridge elements with 'O' ring for 15 to 25 KVA DG set. Complete all as specified and directed by Eng-In-Charge.(Make : Kirlosker/cummins/fleetguard)
Supply only fuel oil filter cartridge elements with 'O' ring for 30 to 63 KVA DG set Complete all as specified and directed by Eng-In-Charge.(Make : Kirlosker/cummins/fleetguard)
Supply only fuel oil filter cartridge elements with 'O' ring for 63 to 160 KVA DG set Complete all as specified and directed by Eng-In-Charge.(Make : Kirlosker/cummins/fleetguard)
Supply only lubricant oil filter cartridge elements with 'O' ring for 15 to 25 KVA DG set Complete all as specified and directed by Eng-In-Charge.(Make : Kirlosker/cummins/ fleetguard)
Supply only lubricant oil filter cartridge elements with 'O' ring for 30 to 63 KVA DG set Complete all as specified and directed by Eng-In-Charge.(Make : Kirlosker/cummins/ fleetguard)
Supply only lubricant oil filter cartridge elements with 'O' ring for 63 to 160 KVA DG set Complete all as specified and directed by Eng-In-Charge.(Make : Kirlosker/cummins/ fleetguard)
Supply only fuel water separator filters cartridge elements with 'O' ring for 63 to 160 KVA DG set Complete all as specified and directed by Eng-In-Charge.(Make : Kirlosker /cummins/ fleetguard)
Material and labour for engine oil 20 W 40 grade in DG Set Complete all as specified and directed by Eng-In-Charge. Make: Castrol/ Servo
Material and labour for coolent of DG Set Complete all as specified and directed by Eng-In-Charge. Make: Castrol/ Servo.
Material and labour for distilled water for battery. Complete all as specified and directed by Eng-In-Charge.
Supply and fixing V-Belt off sizes Make :- Fenner or equivalent as approved by GE complete all as per site requirement and directed by Eng-In-Charge.
Supply and fixing Oil pressure gauge ISI marked. Complete all as specified and directed by Eng-In-Charge.
Supply and fixing Oil temparature gauge ISI marked. Complete all as specified and directed by Eng-In-Charge.
Supply anf fixing Fuel gaugemeter ISI marked operated on 24 V DC Complete all as specified and directed by Eng-In-Charge.
Sully and fixing RPM Meter complete all as specified and directed by Engr-in-Charge.
Supply and fixing AVR as per site requirment Complete all as specified and directed by Engr-in-Charge.
Dismantling of radiator complete from DG Sets cleaning/scraping of depositing manualy from outside of the radiator, cleaning of all copper tubes of radiator with descaling solution from inside & outside with forged feed method & with water and aircompressor (by using separate chemical pump water pump & compressor) plugging of all leakage in welding, brazing of copper tubes, cleaning of fins and replacement of gaskets etc for the capcities up to 166 KVA DG sets. Complete all as specified and directed by Engr-in-Charge.
Matrerail & Labour for dismantling of Exhaust pipe of silencer, cleaning of silencer to remove carbon deposit inside exhaust and refixing including replacement of worn out rubber gasket packing and nut, bolts Complete all as specified and directed by Eng-In-Charge.
Repair and maintenance of alternator of type, with opening the cover cleaning all the parts, removing dust with tightening all the electrical connection, checking the serviceability of automatic voltage regulator and voltage setting, tightening the loose connections, checking and setting the alighment properly cleaning air inlet, opening the terminals box top and front cover and tightening the cable leads, checking insulation resistance closing the covers and testing. Complete all as specified and directed by Engr-in-Charge, for the following capacity of DG Set :-(a) Upto 63 KVA DG set of any make.
All as per Sr item no. 25 above but 63 KVA to 166 KVA DG set of any make.
Disconnecting the defective/burnt Alternator from the engine and removing it from the base frame and shifting it to the workshop, removing rotor and cutting the field copper winding or armature winding and cleaning the slots complete for rewinding and using super enameled copper wire, varnishing and drying using three coats of insulating varnishing reassembling the motor after repairs/ re-setting complete re-installation at site including transportation from the site to and pro, complete of capacity upto 63 KVA DG set of any make. Note - Copper wire required for rewinding shall be measured and paid for separately under Sch 'A' item.
All as Sr. item No. 27 above but capacity 63 KVA to 166 KVA DG set of any make.
Supply only super enamelled copper wire of any size/gauge, or strips as required for rewinding. Complete all as specified and directed by Engr-in-Charge.
M&L for repair and maintenance of metal doors (i.e., front and back door) of DG set of capacity from 18.75 KVA upto 166 KVA, incl taking down door to the work shope from site and fixed suitable hinged incl welding work if required and painting the same as existing colour and refixing the same on DG set. Complete all as specified and directed by Engr-in-Charge.
Replacement of old unserviceable self starter with new self starter, 12 Volts, DC of make as approved for any make and type of Diesel Generator set of capacity upto 166 KVA, Complete all as specified and directed by Engr-in-Charge.
Taking down U/S battery 12V from the DG Set and supply and install 12 V 130-180AH maintenance free battery including terminal clamps, copper lead of suitable size/ length, battery stand complete testing and commissioning all as directed by Engr-in-Charge. Make : Exide/Luminous.
M&L for replacement of battery lead set two suitable for 180 AH capacity 1.5 mtr long including GM terminals one end coper lug and other and including 0.5 mtr connecting both end with gun metal terminals. Complete all as specified and directed by Engr-in-Charge.
Taking out Diesel Tank of any capacity carefully including disconnection from system, descaling the diesel tank with water pressure and removing the complete deposited, drying the tank and painting two coats with super enmelled paint out side the tank size, replacement of gate valve and fixing the tank in original location and connection with existing diesel line with replacement GI/MS fittiing replacement of diesel indicator glass/PVC tube with necessary fitting,repair to any leakage,cleaning and testing of fuel line upto FIP inlet including making of locking arrangements complete up to 600 Ltrs capacity. Complete all as specified and directed by Engr-in-Charge.
M&L for tank calibration including provn of tank level indicator of fibre tube with indication of full tank capacity of showing minimum reading of 0.5 ltrs for DG set upto 160 KVA capacity. Complete all as specified and directed by Engr-in-Charge.
Taking out unserviceable asbetos rope from the exhaust pipe, cleaning the exhaust pipe and supply and wraping new asbetos rope of suitable size and wrapping with wire mesh and plastering with plaster of paris / white cement for smooth finishing including replacment of gasket and tightening of nut and bolts, Complete all as specified and directed by Engr-in-Charge.
Repairs to DG Set enigne upto six cylinder of capacity upto 63 KVA by dismantling/strip opening of the DG Set for overhauling by removing the cylinder head assemble including facing and grinding, piston connecting rod, cylinder liner, oil sump and injector including replacement of worn out spare i.e., cylinder liner with 'O' ring, Piston assembly, connectin rod, large end bearing pair, valve seat, valve guide, FIP element, lubricant oil pump, gasket for cylinder, set of O rings, set of hose pipes, fuel pipes nozzle calibration, FIP caliberation, water pump assembly etc and reassembling the complete engine. Complete all as specified and directed by Engr-In-Charge.
Repairs to DG Set enigne upto six cylinder of capacity upto 166 KVA by dismantling/strip opening of the DG Set for overhauling by removing the cylinder head assemble including facing and grinding, piston connecting rod, cylinder liner, oil sump and injector including replacement of worn out spare i.e., cylinder liner with 'O' ring, Piston assembly, connectin rod, large end bearing pair, valve seat, valve guide, FIP element, lubricant oil pump, gasket for cylinder, set of O rings, set of hose pipes, fuel pipes nozzle calibration, FIP caliberation, water pump assembly etc and reassembling the complete engine. Complete all as specified and directed by Engr-in-Charge.
Supply and fixing on load changeover switch Range 100A, 415V, 4P, confirming to IEC 60947-3, IS/IEC 60947-3 Conforms to Staggered terminals, Site convertible fuse version for open execution Flip-able handle above 400A Interchangeable dual shaft position with site convertibility along with SS enclosure version require separate cable gland box complete all as specified and directed by Engr-in-Charge.
All as per item No. 39 above but of capacity 63 Amp.
M&L for repair and overhalling of FIP Nozzle of capacity 15 KVA to 63 KVA. Complete all as specified and directed by Engr-in-Charge.
M&L for repair and overhalling of FIP Nozzle of capacity 63 KVA to 166 KVA. Complete all as specified and directed by Engr-in-Charge.
S&F of dynamo with 12 Volts DC of make Lues, Diesel Generator set of any capacity. Complete all as specified and directed by Engr-In-Charge.
All as per srl item No-44 above but for voltage stabilizer upto 63 KVA capacity.
All as per srl item No-44 above but for voltage stabilizer upto 160 KVA capacity.
Supply and fixing control cards for output supply of voltage stabilizer of capacity upto 160 KVA. Complete all as specified and directed by Engr-In-Charge.
Supply and fixing control cards for input supply of voltage stabilizer of capacity upto 160 KVA. Complete all as specified and directed by Engr-In-Charge.
Supply and fixing control card for high voltage cut off protection reduction of voltage and automatic ON after 10 second time delay. Complete all as specified and directed by Engr-In-Charge.
Supply and fixing servo motor complete including pinion for voltage correction having speed of correction 8 volts per second of capacity upto 10 Kg Torque. (Make :- AE/ PARADISE/ VOLT AMP)
Supply and fixing indicator lamps to show RYB phase of 3 phase 415 volt 50 Hz AC supply as replacement of defective indicator lamp in existing panel. Complete all as specified and directed by Engr-In-Charge.
Material and labour for complete rewiring for power and control circuit of voltage stabilizer using standard copper wire, replacement of thimbles, connectors numbering of wiring to all control and measuring instrument for capacity upto 160 KVA voltage stabilizer.
Supply and fixing in repairs dimmer for servo stabilizer of capacitie upto 160 KVA. Complete all as specified and directed by Engr-In-Charge.
M&L for filling /toping up of oil in servo voltage stabilizer having dielectric strength upto 35KVA at 2.5mm gap high voltage as per IS/IEC specification of low viscosity. Complete all as specified and directed by Eng-In-Charge.
Supply and fixing in replacement of burnt defective LT copper coil of stabilizer with new one made out of suitable size/guage of copper super enameled wire of high quality matching with the existing impendence and insulation including testing. Complete all as specified and directed by Engr-In-Charge.
Material and labour for servicing/cleaning of complete indoor and out door unit of Ducted Split type / Split Type Air conditioner of AC 2.0 TR capacity by means of adding cleaning solution with water, cleaning of the condensor and chiller tubes shall be done with use of nylon brushes till the scaling is removed and ensuring its serviceability by rectification / replacement of unserviceable parts and keeping AC in good working condition. Complete all as specified and directed by Engr-In-Charge. Note :- Supply of spares for replacement will be measured and paid separately under relevant item of Sch 'A'.
All as sr item no. 57 above but split type AC 1.5 TR.
Taking out unserviceable receprocating type compressor of Split Type AC 1.5 Ton capacity, from site and replacement of compressor against repair of existing make (R Compressor) and re-fixing the compressor sealed unit in position, charging of refrigerant gas R-22 of required quantity, bracing of discharge and suction line and leak testing. Complete all as specified and directed by Engr-In-Charge.
All as per item no. 59 above but for Split Type AC 2 Ton capacity.
Taking out unserviceable rotary type compressor of Split Type AC 1.5 Ton capacity and re-fixing with new Rotary type compressor sealed unit in position, charging of refrigerant gas R-22 of required quantity, bracing of discharge and suction line and leak testing complete as directed by the Engineer-In-charge
All as per item no. 61 above but for Split Type AC 2 Ton capacity
M&L for gas charging with R-22a for split type AC in position including leak testing to achieve desired suction pressure and temperature (or any other cooling applainces also). Complete all as specified and directed by Engr-In-Charge.
Supply only condenser blower motor for Outdoor Split type AC 1.5 / 2 TR capacity.
Supply only condenser blower motor of water cooler / deep freezer of any capacity, make and model.
Supply only Blower motor of indoor unit of split AC 1.5/2TR.
Supply only Fan Blade suitable for 1.5 / 2 Ton Split Type Air conditioner.
Supply only relay for any type of AC any capacity & make.
Supply only OLP for any type of A/C any capacity & make.
Supply only PCB suitable for split /window type A/C 2/1.5 TR of any make.
Supply only wiring kit suitable for split type A/C 2/1.5 TR of any make.
Supply only wiring kit suitable for Window type ACs of any capacity and make.
Supply only Running capacitor 45 mfd for Split type Air conditioner 1.5 Ton Capacity
Supply only Running Capacitor capacitor 60 mfd for Air conditioner 2 Ton Capacity
Supply only auto swing motor for inside unit of split A/C of capacity 2/1.5 TR of any make
Supply only remote control system of split / window type A/C of capacity 2/1.5 TR .
Supply only PVC air filter for split type A/C of any capacity & make .
Supply only contactor suitable for 2/1.5 TR of any make
Supply only Brass angle valve 5/8 inch for split AC 1.5/2TR capacity.
Supply only Copper tubing 5/8" dia for extending refrigerant piping including brazing/adopter and accessories.
Supply only Copper tubing 3/8" dia for extending refrigerant piping including brazing/adopter and accessories.
Supply only Puff insulation to suction pipe of split AC.
Supply only condensor coil for 1.5 Ton Split AC
Supply only condensor coil for 2.0 Ton Split AC
M/s Habib Electronics
M/S PARADISE TRADERS AND CO
M/s FAYAZ AHAMD WANI AND SONS
M/S KULWANT SINGH RAINA AND CO
M/S IQ ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .