Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.8 LAccepted-AOC | 1 | Accepted-AOC LOWEST | |
| 2 | Rejected-Technical | - | Rejected-Technical L4 | |
| 3 | Rejected-Technical | - | Rejected-Technical l2 | |
| 4 | Rejected-Technical | - | Rejected-Technical L5 | |
| 5 | Sreenivasan A S Rejected-Technical | - | Rejected-Technical L3 |
| Sl No | Description | Qty | Unit | S ANILKUMAR L2 | NAZARUDEEN L4 | Sreenivasan A S L3 | Amal raj L1 | S SANIL KUMAR L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00Booster pump at Cherukode karimarathinmoodu road | ||||||||
| 1.00 | OD56048/2025-2026:Supply, Installation of 5HP centrifugal booster pump,3 phase,50 Hz. Capable of discharging 2.25LPS against a total head of 110m. The rate including, cost of pump, cost of motor, cost of panel board(suitable main switch, digital volt meter and ammeter), cost of starter, Aluminum cable from panel board to starter and starter to Motor, cost of Capacitor, suction pipe 10 m length, foot valve, Non return and sluice valve, pressure gauge, pipe connection works for suction side and delivery side , suitable Earthing as per IE rule,Erection charges including foundation , base plate, cost of cement sand and metal, trail run and commissioning etc. complete as per the direction of Engineer incharge | 2 | no | 96,883.04 ₹1,93,766.08 | 1,12,107 ₹2,24,214 | 1,03,803 ₹2,07,606 | 96,882 ₹1,93,764 Lowest | 1,13,491.56 ₹2,26,983.12 |
| 1.00 | OD56050/2025-2026:Protection cover for Booster pump, KYOSK for placing the energy meter starter and pannel board accessories | 1 | no | 32,522 ₹32,522 Lowest | 37,632 ₹37,632 | 34,845 ₹34,845 | 32,522 ₹32,522 Lowest | 38,097.2 ₹38,097.2 |
| 1.00 | OD56049/2025-2026:OYEC amount for taking connection to the Booster pump house including CD, Inspcetion charges etc. complete. | 1 | no | 25,196.42 ₹25,196.42 | 29,155 ₹29,155 | 32,000 ₹32,000 | 25,160 ₹25,160 Lowest | 29,515.81 ₹29,515.81 |
| 1.00 | 100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. | 550 | cum | 485.28 ₹2,66,904 | 570 ₹3,13,500 | 550 ₹3,02,500 | 485 ₹2,66,750 Lowest | 568.47 ₹3,12,658.5 |
| 1.00 | 100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals. | 550 | metre | 22.92 ₹12,606 | 26 ₹14,300 | 26 ₹14,300 | 22 ₹12,100 Lowest | 26.85 ₹14,767.5 |
| 1.01 | OD56936/2025-2026:Supply of PVC Pipe, 12.5kg/cm2, 75mm Dia | 1,100 | metre | 263.06 ₹2,89,366 | 304 ₹3,34,400 | 280 ₹3,08,000 | 262 ₹2,88,200 Lowest | 308.16 ₹3,38,976 |
| 1.01 | 100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes. | 1,100 | metre | 74.64 ₹82,104 | 86 ₹94,600 | 85 ₹93,500 | 74 ₹81,400 Lowest | 87.44 ₹96,184 |
| 1.01 | OD56074/2025-2026:Cost of specials (3% of the pipe cost) | 4,13,380 | L.S | 0.02 ₹8,267.6 Lowest | 0.02 ₹8,267.6 Lowest | 0.02 ₹8,267.6 Lowest | 0.02 ₹8,267.6 Lowest | 0.02 ₹8,267.6 Lowest |
| 1.01 | OD56075/2025-2026:Interconnection to the branch line from existing main line(160mm PVC to-75mm PVC) by using Tee and other specials , labor charges, etc; complete as per direction of departmental officers. | 1 | each | 5,689.15 ₹5,689.15 | 6,582 ₹6,582 | 7,000 ₹7,000 | 5,688 ₹5,688 Lowest | 6,664.43 ₹6,664.43 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
14 Aug 2025, 3:00 pmClosed
EE,HWD,AVK
HWD,ARUVIKKARA
DEPOSIT DISTRICT PANCHAYATHTHIRUVANATHAPURAM 2025 2026-RWSS TO VILAPPIL Pipeline extension work and booster pump with kiosk at Cherukode Karimarathinmoodu in Vilappil GP under Aryanad section pipeline
2025_KWA_783487_1
02/HWD/2025-26
Open Tender
Civil Works - Water Works
Item Rate
180 days
WORKS
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,257
Yes
₹40,000
16 Sept 2025
7 Aug 2025
16 Aug 2025
7 Aug 2025
14 Aug 2025
7 Aug 2025
Amount
Booster pump at Cherukode karimarathinmoodu road
OD56048/2025-2026:Supply, Installation of 5HP centrifugal booster pump,3 phase,50 Hz. Capable of discharging 2.25LPS against a total head of 110m. The rate including, cost of pump, cost of motor, cost of panel board(suitable main switch, digital volt meter and ammeter), cost of starter, Aluminum cable from panel board to starter and starter to Motor, cost of Capacitor, suction pipe 10 m length, foot valve, Non return and sluice valve, pressure gauge, pipe connection works for suction side and delivery side , suitable Earthing as per IE rule,Erection charges including foundation , base plate, cost of cement sand and metal, trail run and commissioning etc. complete as per the direction of Engineer incharge
OD56050/2025-2026:Protection cover for Booster pump, KYOSK for placing the energy meter starter and pannel board accessories
OD56049/2025-2026:OYEC amount for taking connection to the Booster pump house including CD, Inspcetion charges etc. complete.
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
OD56936/2025-2026:Supply of PVC Pipe, 12.5kg/cm2, 75mm Dia
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
OD56074/2025-2026:Cost of specials (3% of the pipe cost)
OD56075/2025-2026:Interconnection to the branch line from existing main line(160mm PVC to-75mm PVC) by using Tee and other specials , labor charges, etc; complete as per direction of departmental officers.
OD56078/2025-2026:Interconnection to the branch line from existing main line by using Tee and other specials
OD56912/2025-2026:providing and fixing 100 mm GI casing pipe
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
100.98.435:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Kinetic Air Valve Type DK, Size 50mm.
100.32.3:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 50mm Double Acting Air Valve.
OD57327/2025-2026:Supplying and fixing protection tube for protectig valve
Providing Automation Systems
OD56053/2025-2026:Supply, erection and commissioning of fully automation system for operating 5 HP Booster pump including GSM based motor remote controller with pressure remote controller, scheduler, protector offers effective protection from motor dry run , overload, single phasing, phase reversal, under voltage and over voltage. Flexible scheduling and timer function with power outage compensation up to 7 SMS users and unlimited number of apps, users per motor, works Potts, Tree, Hub, mobile app, Google Assistants, Amazone Alexa, integrated 65K -TFT color touch screen display with animated graphics for local control and real time monitoring of pump and other connected nodes. Integrated modbus interface for communication with PLC/SCADA systems. Integrated 4-20 mA 12.5 bar pressure sencor input to monitor pipe line pressure, TRANSDUCER-PRESSURE-4-20 MA-12.5 KG/CM2 , ENCLOSURE -METAL-AUTO-PANEL-60X38X8.5 .
S ANILKUMAR (BID ID -2288262)
Sreenivasan A S (BID ID -2288089)
NAZARUDEEN (BID ID -2288622)
S SANIL KUMAR (BID ID -2288161)
Bidder Name
NAZARUDEEN
Sreenivasan A S
S ANILKUMAR
S SANIL KUMAR
Amal raj
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1286159.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .