Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 CrAccepted-AOC | ₹4.8 Cr Quoted ₹4.9 Cr | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹5.3 Cr+₹32.2 L (6.52%)Rejected-Finance 54 AKASH DEEP COLONY CHAKRATA ROAD DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹5.3 Cr+₹32.2 L (6.52%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹5.6 Cr+₹63.0 L (12.8%)Rejected-Finance 14 KISHANGARH WEST IDGAH AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | ₹5.6 Cr+₹63.0 L (12.8%) | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹5.7 Cr+₹77.7 L (15.7%)Rejected-Finance | ₹5.7 Cr+₹77.7 L (15.7%) | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹6.0 Cr+₹1.1 Cr (21.4%)Rejected-Finance CHANDAN NAGAR OPP IOCL PERTROL PUMP RAMPUR ROAD BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | ₹6.0 Cr+₹1.1 Cr (21.4%) | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹7.6 Cr
EMD Value
₹7.1 L
Closing Date
18 Apr 2024, 6:00 pmClosed
CHIEF ENGINEER BAREILLY ZONE
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243001
ADDN ALTN TO TRG SHEDS IN BEG AND CENTRE ROORKEE
2024_MES_643161_1
CEBZ/MRT/T-26 of 2023-24
Open Tender
Civil Works
Item Rate
490 days
ROORKEE
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE MES ROORKEE
₹7.1 L
Yes
23 Jul 2024
19 Feb 2024
25 Apr 2024
19 Feb 2024
18 Apr 2024
8 Apr 2024
Amount
Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridge in roof covering complete all as specified and directed.
S&F 0.50 mm thick pre-painted galvalume zinc coated GI based double ribbed trapezoidal profile sheet of green colour and having profile tensile strenth of 550 Mpa AZ-150 , fixed as in roof covering/cladding to wall with self tapping screws complete all as specified and directed by Engineer-in-Charge. (Note:- Minimum weight of galvalume trapezodial sheet should be 4.8 Kg/sqm)
S&F 0.50mm thick pre-painted galvalume zinc coated GI based plain sheet of approved colour having tensile strenth of 550 Mpa AZ-150, fixed as in roof covering/ cladding to wall, ridges etc with self tapping screws complete all as specified and directed by Engineer-in-Charge.(Note:- Minimum weight of galvalum plainl sheet should be 4.0 Kg/sqm)
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed by engineer in charge.
M&L for rolled mild steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to IS 1161-1979 grade FE-290 (Gde E-165) complete all as specified and directed by Engineer-in-Charge.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L for machine cut Kota stone slab 18-20 mm thick, laid over and including 20mm thick screed bed in cement mortar (1:6) using coarse sand as in flooring, set & jointed in neat grey cement slurry and pointed in white cement mixed with pigment to match including grinding and polishing to granite finish complete all as specified and directed.
M&L for machine cut Kota stone slab 18-20 mm thick, laid over and including 10mm thick rendering in cement mortar (1:4) using coarse sand as in vertical surfaces, set & jointed in neat grey cement slurry and pointed in white cement mixed with pigment to match including grinding and polishing to granite finish complete all as specified and directed.
M&L 25 mm thick PCC (1:2:4) Type B-0 using 12.5 mm stone aggt as in sub floor /roof/chajja complete all as specified and directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets Complete all as specified and directed.
Dismantling floor hearth and wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M & L for Non Skid ceramic tilesof approved colour ,pattern and design 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.18 sq m but not exceeding 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed bed in cement morat 1:4 complete all as specified and directed.
M&L for Colored ,Glazed ceramic tiles of approved colour, pattern and design in vertical surface 300x200x7 /450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and incl provn of 10 mm thick backing coat in CM (1:4), complete all as specified.
Excavating over areas n. exc. 1.5 mtr depth and getting out in soft/loose soil complete all as specified and directed.
M & L Broken stone or boulders Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified
M&L for 75 mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection /path surface finish even and smooth without using extra cement including necessary groove complete all as specified and directed.
M & L 100mm thick Cement concrete 1:4:8 type C-2 using 40mm graded stone aggregate complete all as specified
M & L 40mm thick Cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in floor laid in panels not exc. 2.00 sqm area each finishing with using extra cement complete all as specified
Taking down chowkhat or frame with shutters (without taking off shutters from the frame wooden/steel) exc 1.5 Sqm but n.exc 4 Sqm complete all as specified and directed.
Taking down chowkhat or frame with shutters ((without taking off shutters from the frame wooden/steel) n exc 1.5 Sqm complete all as specified and directed.
S&F steel windows with side hung shutters including box type hinges, steel handles and steel peg stay with glazing bars dovetailed or welded complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, steel handles and steel peg stay complete all as specified and directed.
S&F mild steel framed work such as grills, grating etc with ends of bars shouldered and or riveted or forged in to spikes, framed guard bars, barred iron doors chowkat, ladders, framed balusters, railings and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for preparation of new steel and iron surfaces of any description over 10 Cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specifed and directed.
S&F 3.0 mm thick plain sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed.
S&F II nd class HW, 35 mm thick plain framed Factory made panelled shutter (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F Mild steel door frame by using M.S angle/flat iron, including necessary hold fast and pcc block in cement concrete 1:2:4 type B1 using 20mm graded stone aggregate complete all as specified.(PCC block/Butt hinges shall be mesured and paid seperate).
M & L cement concrete type BO 1:2:4 using (12.5mm graded stone aggregate) in lintels upto 1.5m clear span, crills, steps; seismic and other similar bands, plinth courses, string courses, lacing, courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work etc complete all as specified and directed.
S&F Mild steel butt hinges 100 mm size,heavy weight fixing with stainless steel screws complete all as specified and directed.
S&F 200 mm size Mild steel barrel tower bolt, fixing with stainless steel screws complete all as specified and directed.
S&F 300 mm size Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed with stainless steel screws complete all as specified and directed.
S&F 150 mm Aluminium handles fixed with 4 nos stainless stell screws complete all as specified and directed.
Materials and Labour for brick work with Sub Class ‘B’ bricks straight or curved on plan exceeding 6M mean radius built in cement mortar (1:6), complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all in soft/ loose soil as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 3.0 meter in depth for laying of pipes and for poles/stay and struts not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified.
M&L P.C.C type D-2 1:4:8 (using 40mm graded stone aggregate) in foundation filling and mass concrete
Taking down cement plaster (including tiles) using of any description on Brick walls including racking out Joints, hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:4) using coarse sand on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specifed and directed.
M&L for preparation of newly plastered surfaces of walls and applying two of white wash complete all as specifed and directed.
M&L for preparation of newly plastered surfaces of walls and applying two of OBD over a coat of Chalik whitning primer including 1mm thick wallcare putty complete all as specifed and directed.
M&L PCC 1:2:4 type B-1 using (20mm graded stone aggregate ) as in Foundations, including rafts, footings, foundation beams; plinth beams; lintel beams bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as spcified and directed.
M&L for Form work to sides and soffits of floor or roof beams, beams, plinth beams bases for columns and mass concrete complete all as specified and directed.
M&L for TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L mild steel tmt bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, and as in stirrups all as specified and directed.
M&L for Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed wt n exe 4 kg per sqm complete to fix-steel members complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or MS beads size 2mm to 3mm complete all as specified and directed.
M&L for preparation of old surface of walls and applying two coats of cement base paint complete all as specifed and directed.
M&L for preparation of old decorated wall surfaces including cornices by broming down with steel brush, scrapping down smoke soot, moulds moss and efflorescent salts and trading oil and grease spots and applying one coat of distemper oil bond emulsion by using rollers complete all as specified and directed.
M & L for Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces complete all as specified and directed.
Demolition cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed
M&L for applying one coat of synthetic enamel paint over steel surface exceeding 10 cm in width or girth including preparation of surfaces and including necessary sacffolding complete all as specified and directed. Note: for painting of truss at the height of 8.00 m
S&F 1.25 mm Plain, black, mild steel sheeting, in ridges, hips, valley gutters,drip and straight flashings complete all as specified and directedfixed)
M&L for applying two coat of synthetic enamel paint In new surface over a coat of pink primer on wooden surface exceeding 10 cm in width or girth including preparation of surfaces and including necessary sacffolding complete all as specified and directed.
Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in unframed work complete all as specified and directed.
Dismantling framed trusses span n exc 10 m complete all specified and directed.
M & L for providing and fixing tiled false ceiling of designer tiles (high pressure steam cured) of 4 mm thickness (as per IS:14862) of size595x595mm and any one of the design (Cascade or Electra or equivalent)in true horizontal level, suspended on inner locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grms, both side inclusive and black painted groove on all T webs) consisting of main 'T' runner with suitably spaced joints to get required length and 15x32mm made from 0.3mm thick sheet, 1200mm long spaced between main 'T' at 600cm C/C to form a grid of 1200x600mm and secondly cross 'T' of length 600mm and size 15x32mm made of 0.30mm thick sheet to be interlocking at middle of 1200x600m panel to form grids of 600x600mm and wall angle 15x20x0.36mm and laying false ceiling tiles in the gride including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixture, smoke detectors etc. Main 'T' runner to be suspended from ceiling using GI soffit cleats /by using dash fastners to RCC lintel or slabs/ by welding MS cleats of suitabale size on truss/purlin/rafters, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T' sections shall be pre-painted with polyster paint and black painted groove at centre of size 4mm depth and 4.5mm width, complete at all heights as per directions of EIC.
M & L Vitrified ceramic tiles of approved colour, pattern and design 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed.
S&F in repair sheet glass 4.0 mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed.
M&L 75mm thick Cement concrete 1:4:8 type D- 2, (using 40mm graded stone aggregate) as in sub base etc complete all as specified and directed.
M&L Sand cushioning under paver block, in trenches for cable protection including necessary punning and consolidation as required complete all as specified and directed.
Providing and lying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour,design & pattern as in foothpath, park, lawns, drive ways or light traffic parking etc, made by table vibratory method using PU mould & laquer finish, laid in required colour & pattern over and including 25mm thick compacted bed of coarse sand compacting and proper embedding laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joint with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all specified and directed.
M&L 100 mm thick Cement concrete type B- 2, 1:2:4 (using 40mm graded stone aggregate) as in Floor finish etc complete all as specified and directed.
S&F, Powder Coated aluminium door shutters, having top rail of size 101.60mm x 44.50mm, Middle rail of size 101.60mm x44.50mm , bottam rail of size 150.00mmx44.50mm and side vertical rail of size 83.50mmx44.50mm aluminium section thickness 2 mm including necessary joining cleats, glazing clips, rubber neoprene packing, 2 Nos powder coated handles 200mm long in each door,250mm long powder coated tower bolt, hinges, anodised aluminum snap beading, Mortice lock, screws etc. complete all as specified
M & L for powder coated aluminium window sliding type (3 shutters on 3 track frame type) by using aluminium sections weighing 0.55 Kg/m (min) including, necessary rollar joining cleats, glazing clips, rubber packing, anodised aluminium snap beading screws suitable anodised fitting such as hinges, handles, including anodised aluminium frame, including sheet glass & stainless steel wire mess complete all as specified & directed.(Note:- stainless steel wire mess & glass shall be measured & paid separately under respective items)
M& L for powder coated (50 micron thick) aluminium ventilator fixed type (partly glazed and partly gauzed) with gasket, glazing clip etc, weight of frame not less than 0.55 Kg/RM including necessary joining cleats, rubber packing, anodised aluminium snap beading, screws suitable anodised fittings such as hinges, including glass & stainless steel wire complete all as specified and directed.(Note:- stainless steel wire mess & glass shall be measured & paid separately under respective items)
S&F Anodised aluminium grill of 50x50x5mm size (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge.
S&F sheet glass 5.5 mm thick ordinary quality and glazing with neoprene beading to aluminium frame complete exc 0.5 sqm in each pane complete all as specified and directed.
S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) frame work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge
S & F Prelaminated particle board, 12 mm thick interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with aluminium frame work screws to timber frame work complete all as specified and directed.
S&F for MS hollow rectangular tubes of 60x30mm straight portion, drilled and countersunk for tai bar, balusters running bars, for doors, balusters, nosing to steps including embeding in concrete/ brick work with necessary cutting holes and filling the gap with PCC (1:3:6) and screwing etc. including welding with cross support complete all as specified and directed.
S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of steel, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
M&L for complete removal of existing treatment on surfaces of walls/ceilings by scrapping down with mechanical grinder on old walls as per the specification of manufacturers instructions of paints/OBD complete all as specified and directed.
M&L preparation of newly or old treated plastered surfaces of walls and finishing walls two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004 alkali & fungal resistance dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces of wall/ceiling of projection/ chajja of approved make all as specified and prescribed by manufacturer of paint and including 2mm thick putty on wall complete all as specified and directed. (Note:- contractor shall give 4 years warantee from manufacturers gaurantee against this item rate for same designed to be included in quoted rates
M&L preparation of newly or old treated plastered surfaces of walls and applying with 2 coat of oil bound distemper over a coat of 2mm thick putty on wall,complete all as specified and directed.
S&F rolled mild steel in joist, channel, angle or tee sections fixed independently, without connecting plates etc quality conforming to Fe 410 W (Gde E-50 quality A) complete as specified and directed by Engr-in-Charge
M&L for one coat of synthetic enamal paint including prepration of old wooden surface complete all as specified and directed.
M&L for one coat of synthetic enamal paint including prepration of old steel surface complete all as specified and directed.
M & L for cement concrete 1 :3 :6 type C-2 using 40 mm graded aggregate for foundation basements foundation complete all as specified and directed.
M & L for PCC work type B-1(1:2:4) with 20 mm graded aggregate for coping to poles complete all as specified and directed.
S&F Glass dividing strips, 38mmx 1.5mm thick, inserted in position, conform to design all as specified and as directed
Cutting holes in brick walls (exc half brick but n.exc one brick) in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required all as specified and as directed
MS nuts and bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be provided with one washer and nut all as specified and as directed
Taking down copper/aluminium point wiring (light, fan, socket or power) complete incl fixtures and fittings size as switches, ceiling rose, holder,conduit, regulator, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (Credit for above items should be as per conditions separately) and making good disturbed surfaces of walls, floors etc
M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc including cutting chases for concealed wiring and making good in cement mortar (1:4) to match the existing surfacesand applying surface finises such as distempering etc to match the existing shade of building etc complete all as specified and directed for the following :-
(a) One light point controlled by one way switch
(b) One fan / exhaust fan point controlled by one way switch
(d) One 3/5 pin socket outlet 5 Amp on the same board with other switches.
(e) One 3/5 pin 5 Amps socket outlet on indepandant board.
All as per item No 91 above here in but with 2.5 Sqmm (nominal area) FRLS cable PVC for the 15 Amp 3/5 pin socket power point including 1.5 Sqmm copper conductor green as colour for earth continuity all as specified.
Taking down old sub main wiring and S&F new sub main wiring with two runs of single core FRLS PVC insulated and unsheathed multistranded, copper conductor cable of size 4.0 Sqmm LT, 1100V grade, drawn through and including adequate sizes PVC non metallic conduit of 20mm / approprite dia with accessories and fittings and one run of 4.0 Sqmm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. Cable required for connection to DBs shall be deemed to be included and shall not be measured separately. Earth wire shall run inside the conduit pipe complete all as specified and directed. Note :- Extra length of cable required for connection to MCBs shall be deemed to be included in quoted rate)
All as per item no.91 here in before but 1.5 Sqmm copper conductor and 1.5 sqmm as earth continuity conductor complete all as specified.
All as per item no.91 here in before but 2.5 Sqmm copper conductor and 2.5 sqmm as earth continuity conductor complete all as specified.
All as per item No-91 here in before but 6.00 Sqmm copper conductor and 6.0 Sqmm as earth continuity conductor complete all as specified.
All as per item No-91 here in before but 4x10 Sqmm copper conductor 3 for Phase & 01 for Neutral and one additional run of 10 Sqmm copper conductor for earthing wire complete all as specified and directed.
S&F switch piano flush type polycarbonate single pole one way 5 Amps
S&F switch piano flush type polycarbonate single pole one way 15 Amps
S&F socket outlet polycarbonate 2 in 1, 3 pin 5 Amps flush type
S&F socket outlet polycarbonate 2 in 1, 3 pin 5/15 Amps flush type
M&L for Ceiling rose in poly carbonate 3 terminal brass flush type 6 Amps,250 volts AC ISI marked, fixing on 3 mm thick sunmica hylum plastic laminated round sheet 75mm dia complete all as specified and directed
S&F electronic fan regulator 230 volts , step type (5 step) socket type ,hum free 100/300 watt complete all as specified and directed.
Supply & Fixing Angle holders (metal ring) PVC / polycarbonate type B-22 with back plate, complete with LED bulb 12 watts all as specified and directed. Make: Havells(ROHS) cat part No AHLHXAW000 or equivalent in Anchor( Panta)/ Legrand”
S & F In replacement of old unserviceable light fittings LED tube light fitting 1x20 Watt industrial batten patti type with bipin holders connector block complete with all accessories internally prewired and incl connecting up three core wire incl 01 no. 20 watt retrofit LED tube rod T8 polycabonate to be fixed at any height of wall/ceiling complete all as spd and directed.
S & F In replacement of old unserviceable light fittings LED tube light fitting Integral 9/10watts LED Tube light fitting internally prewired and incl connecting up with two core wire suitable size complete all as specified.
S & F In replacement of old unserviceable Building security light fitting versatile pressure die-cast aluminium with high power LED 30 W as light source complete with LED 30 W 5700K including brackets made out of GI pipe light grade pipe bent to shape incl 02 Nos MS flate clamps incl nut bolts connection complete all as spd and directed
S & F In replacement of old unserviceable bulk head light fittings with new LED bulk head ip 65 with prismatic diffuser 1x10 Watt including LED bulb 10/12 watts white complete with all accessories internally prewired and incl connecting up three core single wire complete all as spd and directed.
S & F In replacement of old unserviceable light fittings LED tube light fitting 2x20 Watt (4 feet) industrial batten box type with bipin holders connector block complete with all accessories internally prewired and incl making fixing arrangement, suspended to ceiling with metal chain-02 Nos, 2 feet length, connecting up three core single wire incl 2x20 watt retrofit LED tube rod T8 polycabonate to be fixed at any height of wall/ceiling complete all as spd and directed.
S & F in replacement of old unserviceable recesss mounting light fitting 2' x 2' of capacity 36 Watts powder coated white CRCA full glow suitable for 600 x600 mm POP false ceiling including making electrical connection from ceiling rose to light fitting complete all as specified and directed.
S & F In replacement of old unserviceable Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar ,single pole and neutral 250 volts ,flush to wall complete all as specified and directed
S & F In replacement of old unserviceable Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar ,flush to wall complete all as specified and directed
Supply and fix in replacement of modular MCB protected plug top and socket board in sheet steel enclosure with 25 Amp rated mini MCB and 25 Amp rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board including taking down existing unserviceable plug & socket board of any description and making good with cement plaster, putty and paint to match with the existing surfacecomplete all as specified and directed .
S&F MCCB / MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed.
S & F MCCB 100 Amp four pole, 415 volt, 16kA adjustable thermal magnetic setting including necessary connection complete all as specified and directed by Engr-in-Charge.
S & F Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar ,triple pole and neutral 415volts ,flush to wall complete all as specified and directed.
S & F MCB single pole, 6 to 40 Amp 240 volt, 'C' curve
S & F MCB single pole and neutral, 6 to 40 Amp 240 volt
S & F In replacement of old unserviceable MCB ISI marked 415 Volt, 50 Hz, TPN 63 Amps.
Earthing complete with GI earth electrode of size 60cmx60cmx6cm buried directly in ground vertically at a depth not less than 2.25 meter below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground surrounded form all sides by 15 cm thick and packed layer of charcoal dust and common salt fitting in alteration layers cleaned connnected to and including GI earth strip 25x 4mm size up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected light grade 50mm dia 5 mtr long GI pipe connected to main control board and GI pipe light grade 20 mm bore for watering and including funnel wire mesh, RCC pit cover 50mm thick with 10mm dia reinforcement 100mm c/c and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 meter) and testing after completion all as specified and shown on plate no 3 of SSR Part - I 2009
Supply and fixing of earth continuity conductor or main earthing lead of size 25x4 mm, GI strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles/ wall or any other indicated situation for loop of earthing etc complete all as directed
S & F LED Highbay light fitting 100 watt capacity with PDC aluminium with reflactor including making electrical connection from ceiling rose to light fitting complete all as specified and directed Note :- The Quoted rate is deemed to be included for installation of light fitting at any height (including High mast, Tower lights, Indoor sports complex etc.) including necessary T & P and safety equipments.
S & F LED Highbay light fitting 200 watt capacity with PDC aluminium with reflactor including making electrical connection from ceiling rose to light fitting complete all as specified and directed. Note :- The Quoted rate is deemed to be included for installation of light fitting at any height (including High mast, Tower lights, Indoor sports complex etc.) including necessary T & P and safety equipments.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed.
Supply and fix exhaust fan, steel body AC single, 900RPM of phase 230V of size 300m sweep with, blades, and frame and louvers including making hole in wall of required size and fix 04 Nos iron washer with nuts and bolts and making good smooth surface complete all as specified and directed
Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 6000 CuM per hour (or nearest size).(Steel body)
Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 5000 CuM per hour (or nearest size).(Steel body)
Supply and fix water cooler electric driven (single phase), having approx storage capacity of 120 litre and nominal cooling capacity of 60 Litres per hour.
Supply and fix water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour.
Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA for Split AC
All as per Item No-139 above but of capacity 2 KVA for Water Cooler.
Labour only for Dismantling existing HT/LT over head line including cross arms and insulators complete all as directed by Engineer-in-Charge for following number of conductors :-
(a) 2 Conductors with / without GI wire
(b) 3 Conductors with / without GI wire
(c) 4 Conductors with / without GI wire
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of cross sectional area as given below:-
(a) 2 Core 25 Sqmm
(b) 4 Core 16 Sqmm
(c) 4 Core 35 Sqmm
(d) 3.5 Core 50 Sqmm
(e) 3.5 Core 70 Sqmm
(f) 3.5 Core 95 Sqmm
(g) 3.5 Core 120 Sqmm
(h) 3.5 Core 240 Sqmm
(i) 4 Core 25 Sqmm
(j) 2 core 10 Sqmm.
M&L for laying bricks in protection covers cables using sub class B old size bricks complete all as specified and directed
( Feeder piller box shall be consisting the following) ( LT Panel CIF Main Office) (a) 4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated of 1 ½ times of the incoming capacity with provision of extension and mounting on porcelain support (b) MCCB FP 200 amps, 35/36 KA , 415 volts, 50Hz (Adjustable type) = 01 No (Incoming) (c) MCCB FP 100 amps, 25 KA , 415 volts, 50Hz (Thermal magnetic release and overload 80-100%) - 03 Nos (Outgoing) (d) MCCB FP 63 amps, 25 KA , 415 volts, 50Hz (Thermal magnetic release and overload 80-100%) - 01 Nos (Outgoing)
(h) RYB indicating lamp, LED type - 01 sets. (j) Cost of PCC for foundation is deemed to be included in quoted rate by the contractor. (k) Drawing shall be approved by GE before placing the order.
(g) RYB indicating lamp, LED type - 01 sets. (h) Cost of PCC for foundation is deemed to be included in quoted rate by the contractor. (i) Drawing shall be approved by GE before placing the order.
Dismantling of HT/LT steel Poles from its existing location and re-erracting the same in its new location with new street light bracket, clamp Nut & bolt and making electrical including Earth work and civil work complete all as directed by Engineer-in-Charge. Note :- (i) Soil re-filling and compacting at place of dismanting of existing poles will be done by the contractor and cost of the same is deemed to be included in quoted rate.
Supply & Fixing new steel tubular poles complete with cast iron base plate, final taper, plug, bolts, nuts & washers as specified type 410 SP-31 (9.0 mtr long) including painting two coats of aluminium paint on exposed surfaces to steel tubular pole of including cross arms, Bracket etc including Making 3 Nos strip / bands painted with post office red and nevy blue colour (300 mm each) in alternate layer from coaping, marking of pole number with black synthetic enamel paint 2.5 cm height including in 3" dia circle etc complete all as specified and directed. Note : Excavation, earth work & PCC works shall measured and paid separately.
Supply & fix PVC Junction box of size 350x250x140 mm with Aluminium bus bars 04 Nos fixed on pole with the help of MS nuts bolts and MS clamps-2 Nos of size 40mm X 5mm thick with one No MCB SP 6 Amp capacity includes making suitable hole on pole to take out connections to fitting if required at site and PVC insulated sheathed multistranded copper conductor 3 core 1.5 Sqmm for making connection from junction box to security light fitting complete including provn of cable glands for incoming and outgoing cables all as specified.
Supply & fix PVC Junction box of size 300x200x105 mm with Aluminium bus bars 02 Nos fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40mm X 5mm thick with one No MCB SP 6 Amp capacity includes making suitable hole on pole to take out connections to fitting if required at site and PVC insulated sheathed multistranded copper conductor 3 core 1.5 Sqmm for making connection from junction box to security light fitting complete including provn of cable glands for incoming and outgoing cables all as specified.
Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron,UL listed,CPRI Tested at 25 KA fault current for one second and is provided with universal clamp made of SS earth enhancing compound shall be of 30kg/pit(resistivity is less than 0.12 Ohm meter) tested as per IEC 62561-7.The above arrangements shall be provided with heavy duty earth poly plastic pit cover of 6000 kg load bearing capacity (Size:270 x 240 x 200mm) and FRLS insulated copper conductor of size 6 sqmm, single core cable drawn through and including suitable dia of medium grade GI pipe upto 7 mtr incl cutting and chases on wall and floor complete all as specified and directed. Note: The rate quoted above shall be deemed to be included for excavation and earth work, refilling, removal of surplus earth and making good the surface around chemical earthing.
Returning, filling, including, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for fine sand free form sharp material as in filling in trenches for cable protection incl necessary punning and consolidation as reqd complete all as spd and directed
M/S SURAT SINGH AND SONS
JASPAL SINGH & CONST
M/s Ravindra Kumar Gupta & Sons
BHARAT ELECTRICAL TRADERS
JYOTI ENTERPRISES
Shree Construction Co.
AMIT ASSOCIATES
imran construction company
CHITTER MAL & CO
Siya constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .