Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.3 L+₹54,610 (2.76%)Rejected-Finance C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L2 | Rejected-Finance L2 | |
| 3 | L3₹24.0 L+₹4.2 L (21.5%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
8 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Bhamre Kiran S
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No.1 Jamnagar 361 003
REPAIR/MAINTENANCE OF POWER STATION NO. 1 AND NO. 2 AND ALLIED WORKS AND RING MAIN CABLES AND CONNECTED WORKS UNDER GE (AF) JAMNAGAR NO 1
2021_MES_493980_1
8141/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Jamnagar
Please refer Tender Documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No. 1
₹40,000
Yes
8 Feb 2022
11 Dec 2021
10 Jan 2022
11 Dec 2021
8 Jan 2022
25 Dec 2021
60 days
Amount
Disconnecting & Taking out LT underground aluminium conductor of size 10 sqmm 2/4 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed.
Disconnecting & Taking out LT underground aluminium conductor of size 16 sqmm 4 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed.
Disconnecting & Taking out LT underground aluminium conductor of size 25 sqmm 3.5 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed.
Disconnecting & Taking out LT underground aluminium conductor of size 35 sqmm 3.5 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed.
Disconnecting & Taking out LT underground aluminium conductor of size 50 sqmm 3.5 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed.
Disconnecting & Taking out LT underground aluminium conductor of size 70 sqmm 3.5 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed.
Disconnecting & Taking out LT underground aluminium conductor of size 95 sqmm 3.5 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed.
Disconnecting & Taking out LT underground aluminium conductor of size 120 sqmm 3.5 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed..
Disconnecting & Taking out LT underground aluminium conductor of size 150 sqmm 3.5 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed.
Disconnecting & Taking out LT underground aluminium conductor of size 185 sqmm 3.5 core from trenches / walls / ducts, including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed.
Note for item No 01 to 10:- Excavation and earth work will be measured and paid seprately under respective items of this schedule
Laying only LT underground aluminium conductor of size 10 sqmm 2/4 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 16 sqmm 4 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 25 sqmm 3.5 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 35 sqmm 3.5 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 50 sqmm 3.5 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 70 sqmm 3.5 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 95 sqmm 3.5 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 120 sqmm 3.5 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 150 sqmm 3.5 core in trenches / wall / ducts, etc., complete all as specified and directed.
Laying only LT underground aluminium conductor of size 185 sqmm 3.5 core in trenches / wall / ducts, etc., complete all as specified and directed.
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 sq. mm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Note for item No 11 to 30:- (i) Excavation, Earthwork, sand cushioning, cable cover and joints (straight through/ termination) will be measured and paid seprately under respective items of this schedule.
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 2 to 4core, 16 to 25 Sqmm all as specified and as directed
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5core, 35 to 50 Sqmm all as specified and as directed
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 70 to 95 Sqmm all as specified and as directed
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 120 to 185 Sqmm all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft / loose soil
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Hard / dense soil
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft / disintegrated rock.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Hard rock.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated material (soil) exc. 50m but n.exc 100 m and depositing where directed at a level n exc. 1.5 m above the starting point
M&L for providing dry river sand as in sand cushioning to under ground PVC cable including punning down of sand in layer all as specified and directed. (Note: Work shall be executed as per clause 19.75 of standard schedule of rates part-1 (2009). For measurement purpose thickness of sand after punning down will be considered.)
Laying only PCC cable cover for LT/HT UG cable, of any description retrieved from item No 1 to 10, all as specified and directed by Engr-in-Charge
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV , Type I , flat size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed.
S&F Tubes, 'light grade', galvanised, mild steel of 40mm dia with all fitting; laid in trenches / wall for protection of underground cable complete with fittings and fixtures.
S&F Tubes, 'light grade', galvanised, mild steel of 50mm dia with all fitting; laid in trenches / wall for protection of underground cable complete with fittings and fixtures.
S&F Tubes, 'light grade', galvanised, mild steel of 80mm dia with all fitting; laid in trenches / wall for protection of underground cable complete with fittings and fixtures.
S&F Tubes, 'light grade', galvanised, mild steel of 100mm dia with all fitting; laid in trenches / wall for protection of underground cable complete with fittings and fixtures.
M&L for horizontal boring under roads / pavement / hard standing without disturbing the top surface by trench less technology using ultra sound technique and necessary machine including inserting of HDPE pipe of 90 mm dia(ISI marked) suitable for 0.4 mpa working pressure for passing through the cables complete all as specified and as directed. Note : Necessary infrastructure required for boring shall be arranged by the Contractor at his own cost.
M&L for horizontal boring under roads / pavement / hard standing without disturbing the top surface by trench less technology using ultra sound technique and necessary machine including inserting of HDPE pipe of 150 mm dia(ISI marked) suitable for 0.4 mpa working pressure for passing through the cables complete all as specified and as directed. Note : Necessary infrastructure required for boring shall be arranged by the Contractor at his own cost.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm to 120 sqmm complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 90 sqmm to 120 sqmm complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 90 sqmm to 120 sqmm complete all as specified and directed
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sq. mm 3 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 120 sq. mm 3 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete. Note for Item No 51 & 52: (i) Earthwork, sand cushion, cable cover will be measured and paid separately under respective items of this Schedule. (ii) Straight through joint will be measured and paid separately.
Deployment of manpower and cable fault locator machine duly mounted on vehicle for detection of HT UG cable fault of any size & make by applying upto 15 KV supply to locate the fault. Necessary arrangements required should be provided by the contractor. Note: Payment under this item shall be measured and made only if any fault is detected.
Taking out HT underground cable from trenches / pole etc, aluminium conductor of size 95 sqmm 3 core including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed.
Taking out HT underground cable from trenches / pole etc, aluminium conductor of size 120 sqmm 3 core all including cable covers, sand cushioning, joints, tubes, etc., complete all as specified and directed..
Laying only HT underground cable from trenches / pole etc, aluminium conductor of size 95 sqmm 3 core all as specified and directed.
Laying only HT underground cable from trenches / pole etc, aluminium conductor of size 120 sqmm 3 core all as specified and directed.
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class HV , flat of size 300 mm X 180 mm X 40 mm in trenches as protection to HT UG cable all as specified and directed.
Note :For Item no. 1 to 60 :- If any of above HT/LT Equipment and connected items breakdowns, the contractor shall locate the problem/fault at site within 12 hours on intimation by JE/ Engineer-in-charge and ensure that the fault is rectified within 48 Hours, failing which an amount of Rs. 200/- per hour will be recoverd as penal recovery from any payment due to the contractor after expiry of 48 hours. Rates quoted under item Nos. 1 to 60 are deemed to include for the same.
KRISHNA ENGINEERING
Chamunda Kruparefrigeration
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .