Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹30.8 L+₹52,913.55 (1.75%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹33.8 L+₹3.5 L (11.5%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹34.1 L+₹3.8 L (12.6%)Rejected-Finance 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹34.4 L+₹4.0 L (13.3%)Rejected-Finance 7 NO SABJEE MAHAL ORDERLY BAZAR PO PS BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
21 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Barrackpore
Office of the Garrison Engineer Barrackpore
SPL REPAIRS TO BLDG NO.48/F, ADDN/ALTN OF BLDG NO.12, PROVN OF BODY STORE ROOM AT MORTUARY AND CERTAIN REVENUE AND MINOR WORKS AT BARRACKPORE UNDER GE BARRACKPORE
2021_MES_445830_1
8512/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹68,000
Yes
2 Jul 2021
25 May 2021
23 Jun 2021
25 May 2021
21 Jun 2021
15 Jun 2021
60 days
Amount
Dismantling timber scantlings (un-framed work) 40 sq.cm and over in section, in any position complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi-corrugated etc.) sheets in roof coverings complete all as specified and directed.
Hacking out old broken glass (any thickness size quality or description) from wooden or steel frame, glazed with putty or fixed with beads etc complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutter from the frames) exceeding 1.50 Sqm and not exceeding 4.00 Sqm each complete all as specified and directed.
Taking down of shutter of any description exceeding 1 Sqm and not exceeding 2.0 Sqm each complete all as specified and directed.
Taking down of shutters of any description exceeding 1 sqm but not exceeding 2 sqm each and refixing in same/other opening after easing and adjusting completed all as specified and directed.
Surface dressing in soft /loose soil not exceeding 15 cm deep complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation or for shafts, well, cesspits, pier holes, laying under ground cable, foundation and erection of poles and stays etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches for laying under ground cable, foundation and erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and exceeding 1.5 meter but not exceeding 3.0 meter deep and getting out complete all as specified and directed
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for Moorum/Red Bajri filling in floors or pavings, layers not exceeding 15 Cm thick spread, levelled and rammed including watering complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in foundations including rafts, footings, foundation beam, plinth beams, bases for columns etc, basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in column, pillar, piers, post and struts etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) used as in bed block, hold fast, coping, door cills and like etc including necessary form work complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
M&L for 20mm thick damp proof course to horizontal or vertical surface including necessary form work in cement morat (1:2) mixed with WPC as per manufacturer's instructions complete all as specified and directed. (Note: WPC will be measured and paid separately)
Supply only integral water proofing compound, ISI marked complete all as specified and directed.
M&L for form work to sides of concrete foundation, footing, bases of column, raft & plinth beam for flat, rough finish surface of concrete complete all as specified and directed.
M&L for form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc for flat, rough finish surface of concrete complete all as specified and directed.
M&L for form work to sides of pillar, posts, struts, piers, columns and stanchions for flat, rough finish surface of concrete complete all as specified and directed.
S&F for second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints of second class hard wood etc complete all as specified and directed.
M&L for second class hard wood in scantling, clean swan, fixed complete all as specified and directed.
S&F for 35mm thick (factory made) plain, second class hard wood, framed, panelled shutters (three panels) with lock rails and panel of 12 mm veneered particle board with commercial veneering on both faces (BWR type), the size of rail and stile as per IS-1003 (Part-I) (larger size to be provided) klin seasoned and chemically pressure treated fitted to chowkats complete all as specified and directed.
S&F for 35mm thick second class hard wood glazed/ gauge & skeleton shutters (factory made), open rebated & prepared to receive glass, gauge etc. (with sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR part-I, section-8, clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
S&F for 30 mm thick flush door shutters (factory made) solid core construction with block board core and plywood face panels commercial type on both sides complete all as specified and directed.
S&F for 250 mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F for 300 mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F for 100 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F for 100mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
S&F for stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple complete all as specified and directed.
S&F for stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple as in repair complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F for mild steel hold fast made out of flat iron (25mm x 3mm) including tarring or coal tar black paint and with drilling necessary holes etc conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed.
S&F for rolled mild steel roof trusses (framed) and purlins, rafters crane gantries, rails, heavy brackets etc including distance pieces, cleats, angle, tee etc including necessary cutting , welding etc complete Fe-410W (Gde E-250) quality 'A' complete all as specified and directed.
S&F for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. not exceeding 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and directed.
S&F for mild steel screw bolts (machine made) 11 to 15mm dia with hexagonal head at one end and screwed the other end, each screw end to be fitted with two washers and one hexagonal or square nut, length of bolts 50mm to 100mm complete all as specified and directed.
S&F for mild steel bolts purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long with neck of 12mm dia complete all as specified and directed.
S&F for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates including where required drilling, fittings, riveting or welding connecting with fish plate, gusset plates etc of Fe-410-W (Gde E-250) quality 'A' complete all as specified and directed.
S&F for steel windows with side hung double shutters (glazed & gauged) including box type hinges with steel handle, steel peg stay, complete with glazing bars (weight not less than 44 Kg/Sqm) , dovetailed or welded to receive wire mesh/glass after and including taking down old unserviceable one complete all as specified and directed.
S&F for steel ventilator with top hung double shutters (glazed & gauged) including box type hinges with steel handle, steel peg stay, complete with glazing bars (weight not less than 44 Kg/Sqm) , dovetailed or welded to receive wire mesh/glass after and including taking down old unserviceable one complete all as specified and directed.
S&F for anodised (powder coating of minimum thickness 50 micron) aluminum frame (powder coated) for doors , windows, ventilators with one or more rebates (sliding & fixed type) including jointing cleat for fixing etc complete all as specified and directed.
S&F for anodised (powder coating of minimum thickness 50 micron) aluminium window/ventilators shutters, sliding/fixed type without sash bar, aluminum section weighing 0.55 Kg/m, including necessary joining cleat, glazing clips, rubber neoprene packing, hinges type B-21 100 mm long (02 Nos), peg stay 150mm long (01 No), anodised aluminium snap beading, screws etc complete locking arrangement, roller complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
S&F for false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee gird false ceiling using “T” Gird System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 4mm thick non asbestos fibre cement board (Make: Everest, type/pattern -oceanic or equivalent of Armstrong/Charminar) of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T gird Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Gird module to form complete all as specified and directed.
S&F for 605mmX605mm grid Gl frame work for seamless false ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including 12 mm thick perforated particle board for insulation/acoustic purpose of 600mmX600mm in size fixed with snap grid false ceiling frame and applying two coats of oil emulsion distemper and 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with 'L' or 'J' type hooks complete all as specified and directed.
M&L for 6mm thick fibre asbestos cement two pieces adjustable serrated ridge for corrugated or semi- corrugated sheets fixed with 'L' or 'J' type hooks complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in flooring of drain and finished the surface even and smooth with using extra cement complete all as specified and directed.
M&L for 40 mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in flooring and finished the surface even and smooth with using extra cement complete all as specified and directed.
M&L for 50 mm thick PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate), as in hard standing and plinth protection etc finishing cement concrete surfaces even & smooth without using extra cement complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection/paving, finish the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 75 mm thick PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in subbase of floor complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured (colour & shade as approved by GE) tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in colour cement to match over and including 15mm thick Screed bed or beading layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
All as per Item No.70.00 here-in-before but in skirting/dado over and including a backing coat of 10mm thick plaster in cement mortar (1:4) complete all as specified and directed.
M&L for vitrified dark shade (shade as approved by GE) ceramic tiles (ultra charge) 10mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 Sqm in floors etc set over and including 15mm screed bed in cement mortar (1:6) and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface of size 300 mmX 200 mmX7 mm thick set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering of cement mortar (1:4) complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 20mm thick rendering in cement mortar (1:4) on brick work walls, surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair face of brick works or concrete surfaces of walls in cement mortar (1:4) mixing with WPC as per manufacturer's instructions, finished the surfaces even & smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately)
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for applying two coats of cement based paint on old plastered surface of walls after complete removal of existing treatment complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3 mm thick wall care putty on wall after preparation of newly plastered surfaces complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3 mm thick wall care putty on wall after preparation of new wall surface complete all as specified and directed.
M&L for applying one coat of oil emulsion distemper over old distemper plastered surfaces of wall after preparation of surfaces complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over and including a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm in width or girth complete all as specified and directed.
S&F for 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F for 5.5mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F for 15mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing steel tubing complete all as specified and directed.
S&F for 20mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing steel tubing complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with the existing surfaces and applying white/ colour wash/distemper after applying putty for smooth finish surface complete all as specified and directed.
M&L for point wiring (concealed) complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces and applying white/colour wash/distemper after applying putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular box, top cover plate, blank plate, MS box, screws, washers etc are to be used of same make/brand only and cost of the same shall be deemed to be included in quoted rate only.)
One light point controlled by one switch .
One fan point controlled by one switch and one regulator.
One exhaust fan point controlled by one switch .
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
One 3 pin 5 amps socket point controlled by one 6 amps switch on independent board .
All as per Item No.91.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on same board.
S&F for modular switch 10 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F for modular switch 16 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F for modular switch 16 Amps, single pole, 1way, 1 module, 240V, AC, ISI marked complete all as specified and directed.
S&F for modular socket shuttered type 6 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F for modular socket 6/16 Amps, 6 pin combined shutter socket, 2 module with light indication, 240 V, AC, ISI marked complete all as specified and directed.
S&F for modular bell push, 6Amps, 1 module, single pole, 1 way, 240V, ISI Marked complete all as specified and directed.
S&F for modular fan regulator, electronic, stepped type (01 to 4/5), 100 to 120 Watts, 240Volts, AC, ISI marked complete all as specified and directed.
S&F for modular red colour lighting indication lamp 6 Amps, single pole, 240volts, AC, 50 Hz suitable for 1 module ISI Marked complete all as specified and directed.
S&F for call bell, AC, 230 Volts single pole, multi music type ISI marked complete all as specified and directed.
S&F for angle lamp holder, insulated body with back plate for batten fittings in and including LED lamp 10 watts complete all as specified and directed.
S&F for batten holder /angle lamp holder, PVC/polycarbonate type, ISI marked complete all as specified and directed.
S&F for ceiling rose , three terminal, PVC/polycarbonate body, ISI marked complete all as specified and directed.
S&F for decorative box type 16 -20watt LED fitting with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible conductor cable of 0.50 Sqmm size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC as approved for LED lamp as approved)
S&F for 6/6.5 watt LED bulk head fittings available in non PIR as well as PIR sensor with premium quality defuser for glare free light and easy to install snap fit installer including LED lamp and fixing arrangements at any height with nuts, screws and washers and necessary electric connection of suitable size copper wire complete all as specified and directed. (Make: Havells cat No.LHEXCGP7IN5W006 / Bajaj cat No BIBWP 6W LED as approved)
Fixing only LED security light fitting with LED lamp of any wattage and any description including necessary electric connection from looping box to light fitting with using required size copper wire complete all as specified and directed. (NOTE: LED security light fitting including lamp will be issued under Schedule 'B' as free for fixing only)
S&F for recess mounting 2'x2' LED 34/36 Watt light fittings with LED lamp and required driver, slim in class LED ceiling panel with best in class aesthetic white powder coated frame blended seamlessly with ceiling layout modular ceiling grid and also can be suspended with provided kit and including connecting up with ceiling rose to fitting with necessary suitable size copper wire complete all as specified and directed . (Make: Bajaj Cat No. BCTBLR 36W LED FP CW/Crompton Cat No.LCTLSNE-36-F0-CDL/ Havells Cat No.PLUTOSURFACE4X1PLS34WLED857S as approved)
S&F for 35/40 watts LED post top decorative lantern with LED lamp made in cast aluminium spigot housing with decorative opal polycarbonate diffuser and IP65 protection with suitable fixing arrangements such as lugs, glands, nuts,bolts and washers etc including necessary electric connection with suitable size copper wire complete all as specified and directed. (Make : Bajaj Model BGCS 40W LED WH /Havells cat No. CORALPT35WLED757PSYMTOPC /Crompton Greaves Cat No.LPTM-40-CDL as approved)
Supply, fabricated and fixing of street light bracket made out of 40mm dia GI pipe, medium grade, bent to shape of 1.2 mtr long including clamps made out of 30 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size complete all as specified and directed.
S&F powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 100amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way / Hager cat No.VYS08D / L&T Cat No.DBSPN008GD as approved)
S&F for powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 4 way suitable for flush mounting with 100amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB TPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed. (Make:- Legrand cat No. 5076 80 4 way / Hager Cat No.VYT04DD/ L&T Cat No. DBTPN004GD as approved)
S&F for suitable for flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C' series, 240 Volts complete all as specified and directed. (Make : Legrand Cat No. 5078 11/Havells Cat No. DHDPUSN020/L&T Cat No. DBMPS220SD as approved)
S&F for MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed (Make: L&T /Havells/Legrand as approved)
S&F for MCB, SPN, 40 Amps to 63 Amps, 10 KA, 'C' series, AC, 240 volts, ISI marked complete all as specified and directed. (Make: L&T /Havells/Legrand as approved)
S&F for MCB, TPN, 40 Amps to 63 Amps, 10 KA, 'C' series, AC, 240 volts, ISI marked complete all as specified and directed. (Make: L&T /Havells/Legrand as approved)
S&F for MCCB, 100 Amps, 4 pole, 25KA breaking capacity Icu at 415 Volt with thermal magnetic release, 50 Hz complete all as specified and directed. (Make - L&T Cat No. CM91712OOKOOG or equivalent of Legrand/Hager as approved)
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically (earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 5 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value complete all as specified and directed. (Galvanised iron wire of 4mm dia upto 7.5m including testing consider in this item).
M&L for maintenance free chemical earthing system using Isogel of M/S Tracel or equivalent of Macmet / Erico chemical of 40 kg per earth pit for enhancing the soil conductivity and copper tube electrode of size 65 mm dia, 3 mtr long having wall thickness 3mm to be placed at the centre of 153 mm dia bore vertically in ground. The tube shall be filled with isogel and the surroundings shall be filled tightly with mixture of isogel and soil. Use of 4 Nos copper rods of 16 mm dia, 3 mtr long and place them in 65 mm dia, back filled with mixture of isogel and soil. The distance of rod from tube shall be 06 mtr and at the angle of 90 degree. These four rods to be connected using 25x3 mm copper strip, laying at least 60 cm below GL and back filled with mixture of Isogel & soil. The connection of copper tube with copper strip should be done using Bi-metalic 'U' clamps. The tubes will be used as earth points and copper strip is to be extended upto test point upto maximum length of 7.5 mtr. The test point shall be made of brass of size 120x120x25 mm in IP-55 enclosure. The copper tube must be laid through 40mm dia GI medium grade pipe. The earth pit cover shall be made out of PVC material with locking arrangement. The work shall be carried out by the authorised representatives/ agent of Idelec/Macmet/Erico in presence of Engr-in-Charge and the test result of earth resistance must be less than 1 ohm complete all as specified and directed. (Note :-1. The unit rate quoted by the contractor shall deemed to be included the drilling to any type of soil, soft / hard, disintegrated rock etc if met during excavation by suitable earth mover machine, to achieve the required depth of 03 mtr below average ground level. 2. All jointing to be carried out by brazings in lieu of bolts & nut.)
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed or any other indicated situation as required of copper strip of size 20X3 mm complete all as specified and directed.
S&F for test point termination block made of gun metal or phosphorous bronze size 75mmX75mmX25mm drilled and screwed including 3 Nos, 8mm dia 25mm long hex head screw complete all as specified and directed.
S&F for heavy duty type exhaust fans AC single phase 230/240 V of size 380 mm sweep, 900 RPM with louver and necessary connection, testing including cutting the existing wall surfaces of brick/stone masonry and making the hole of any height for fixing the exhaust fan with nuts, bolts and washers after grouting in PCC including mild steel jalli and wooden frame for avoid insects complete all as specified and directed. (Make : Havells model No Turbo Force SP 380mm-900RPM or equivalent model of Crompton Greaves as approved)
S&F for heavy duty type exhaust fans AC single phase 230/240 V of size 300 mm sweep, 900 RPM with louver and necessary connection, testing including cutting the existing wall surfaces of brick/stone masonry and making the hole of any height for fixing the exhaust fan with nuts, bolts and washers after grouting in PCC including mild steel jalli and wooden frame for avoid insects after and including taking down of existing exhaust fan and deposit to MES store yard complete all as specified and directed. (Make : Havells model No Turbo Force SP 300mm-900RPM or equivalent model of Crompton Greaves as approved)
S&F for ceiling fan of size 1400 mm sweep, high speed, single phase, 240Volts, AC, 50Hz, as approved colour and including hanging GI hook with necessary suitable MS clamps and connecting cable three core 0.75 sqmm round PVC sheathed from ceiling rose to fan connector and testing after and including taking down of existing exhaust fan and deposit to MES store yard complete all as specified and directed. (Make:- Havells model No. XP-390 or equivalent model of Crompton Greaves/Usha/Bajaj as approved)
S&F wall mounted fan 450mm sweep, high speed, 240 volts, AC, 50 Hz and fixing arrangement on wall including providing hole fasteners 02 Nos after and including taking down existing old unserviceable one and deposit to MES store yard complete all as specified and directed. (Make:Havells model No. Airboll Hi-Speed or equivalent model of Crompton Greaves/Usha/Bajaj as approved)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 6 sqmm, 2 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 50 sqmm, 3.5 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed.
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
M&L for providing cement concrete (1:4:8), type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling for poles complete all as specified and directed
M&L for providing cement concrete (1:2:4), type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for sub main wiring (concealed) including chase cutting complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed . (Note : Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity, one run of PVC conduit of size 25mm dia and chase cutting shall be measured as one unit)
M&L for sub main wiring (concealed) including chase cutting complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed . (Note : Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity, one run of PVC conduit of size 25mm dia and chase cutting shall be measured as one unit)
S&F for water storage heater (geyser) of 25 ltrs capacity, vertical type with copper inner tank, 240 volts, AC, 50Hz and fixing arrangement on wall including providing hole fastners-04 nos, hot & cold water PVC pipes 15 mm bore approximate 600 mm long -2 Nos, chromium plated brass stop cock 15 mm bore -01 No and including necessary plumbing work, testing after and including taking down existing old unserviceable geyser and deposit to MES Store yard complete all as specified and directed. (Make: Havells/Crompton Greaves /Racold as approved)
M&L for 40mm dia pipe (medium grade) made of galvanised iron in any length including embedded in wall both ends duly welded mild steel hold fast at both ends of GI pipe including providing PCC work (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) complete all as specified and directed.
M&L for GI pipe 40mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, on wall, floors, on roof, on pole for cable protection complete all as specified and directed.
M&L for boring holes horizontally under road without damaging the surface of road (minimum 1.0m bellow the road surfaces) with the help of GI tubing of any dia not exceeding 80mm dia for passing of UG cable complete all as specified and directed.
S&F for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified conforming to IS- 2317/1980 type 410 SP-31 (9 metres long) complete with cast iron base plate including staying the poles in a truly vertical position till the foundations are properly set, including painting to pole (inside & outside) with two coats of aluminium paint on exposed surfaces of poles and two coat of black bituminous paint on embedded portion complete all as specified and directed. (Note: Earth work, foundation concrete and coping will be measured and paid separately)
S&F for junction box, water & fire retardant proof, outdoor type made out of external dimensions 400mmX300mmX 190mm single door type hinged with locking arrangement front operated with one number MCB single pole of 6 Amps 240V, 10KA, 'C' series capacity for housing 3 phase and neutral bus bar including connecting the incoming/out going cables glands SMC quoted clamps, bolts etc all and fixed to the steel tubular poles/PCC poles with mild steel flat iron of size 25mm X 4mm complete all as specified and directed. (Make: Sintex Cat No. GSJB 4030 or equivalent of Hensel as approved)
M&L for PVC conduit heavy duty of size 20mm dia from looping box to street light connector, holding in MS clamp of size 25X2 mm thick at every one mtr used in each pole 04 Nos of clamps with necessary nut, bolts and washers etc including PVC sheathed three core multistranded copper conductor cable of size 1.5 sqmm from looping box to light fittings connector complete all as specified and directed.
Fixing only solar LED stand alone street light fitting of any wattage and any description including tubular pole, battery etc (complete set) as per manufacturer's instructions including necessary electric connection using required size copper wire complete all as specified and directed. (NOTE:(i) Necessary earth work, concrete work for foundation etc are deemed to be inclusive in the quoted rate of the item as per OEM recommendation if required (ii) LED Solar light fitting including LED lamp, tubular pole and battery (complete set) will be issued undier Schedule 'B' as free for fixing only)
C. P. ENTERPRISE
S..S. ELECTRIC CO.
DAS ENTERPRISE
CHATTERJEE CONSTRUCTION AND SUPPLIERS
ABHISHEK CONSTRUCTION CO
M/S RAJESH TRADING CO
SENCO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .