Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹33.3 L+₹2.2 L (7.06%)Rejected-Finance H NO 02 BALLUPUR ROAD DEHRADUN UK PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | Rejected-Technical 2523 B LANE NO 3 TURNER ROAD DEHRADUN 248002 | DEHRADUN | UTTARAKHAND | 248002 | - | Rejected-Technical Not fulfilling the eligibility criteria |
| Sl No | Description | Qty | Unit | M/S VIJAY TRADERS L2 | KAPOOR ELECTRICALS L1 |
|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed | 9.7 | Cum | 150 ₹1,455 | 100 ₹970 Lowest |
| 2.00 | M&L 75mm thick PCC (1:3:6) type C-2 (Using 40mm graded stone aggregate) as in plinth protection /hardstanding , laid in panels, finished the top surfaces even and fair without using extra cement complete all as specified and directed | 80 | Sqm | 360 ₹28,800 | 220 ₹17,600 Lowest |
| 3.00 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed | 0.2 | Cum | 200 ₹40 Lowest | 500 ₹100 |
| 4.00 | M&L RCC (1:2:4) type B-1 (Using 20mm graded stone aggregate) as in beams and roof including balconies, canopies, deck slabs or in Chajja/facia projection and the like complete all as specified and directed | 0.2 | Cum | 6,000 ₹1,200 | 5,200 ₹1,040 Lowest |
| 5.00 | M&L mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed | 40 | Kg | 99 ₹3,960 | 94 ₹3,760 Lowest |
| 6.00 | Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for fair finished surfaces (Horizontal or sloping) complete all as specified and directed | 6 | Sqm | 300 ₹1,800 | 100 ₹600 Lowest |
| 7.00 | Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed | 10 | Cum | 200 ₹2,000 | 100 ₹1,000 Lowest |
| 8.00 | M&L brick work with sub class "B" old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed | 10 | Cum | 5,500 ₹55,000 | 4,400 ₹44,000 Lowest |
| 9.00 | M&L for half brick work with subclass ‘B’ bricks, straight or curved on plan to any radius built in CM 1:4 complete all as specified and directed | 10 | Sqm | 2,800 ₹28,000 | 700 ₹7,000 Lowest |
| 10.00 | Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size n.exc 1.50 Sqm complete all as specified and directed | 4 | Each | 100 ₹400 Lowest | 150 ₹600 |
Tender Value
₹44.1 L
EMD Value
₹88,200
Closing Date
3 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Clement Town
GE Clement Town MES Dehradun
SPL REPAIR TO GK VILLA ROOM, (EAGLE NEST) BLDG NO. T-9 OF 614 EME BN, ADDITION/ ALTERATION TO CHAJJAS AND EXTERNAL PLASTER OF BLDG NO. P-9 AND P-41 AT NHO AND PROVN OF THREE PH ELECT CONNECTION, ELECT POWER POINTS, SWITCH BD AND CONNECTED ITEMS TO BL
2025_MES_706931_1
GE/CLT/ Of 2025-26
Open Tender
Civil Works
Item Rate
180 days
GE Clement Town
Class D Cat a(i)
7 documents required · 7 mandatory
₹500
Yes
GE Clement Town
₹88,200
Yes
7 Aug 2025
6 May 2025
10 Jun 2025
7 May 2025
3 Jun 2025
20 May 2025
Amount
Demolition of cement concrete (un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed
M&L 75mm thick PCC (1:3:6) type C-2 (Using 40mm graded stone aggregate) as in plinth protection /hardstanding , laid in panels, finished the top surfaces even and fair without using extra cement complete all as specified and directed
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed
M&L RCC (1:2:4) type B-1 (Using 20mm graded stone aggregate) as in beams and roof including balconies, canopies, deck slabs or in Chajja/facia projection and the like complete all as specified and directed
M&L mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for fair finished surfaces (Horizontal or sloping) complete all as specified and directed
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed
M&L brick work with sub class "B" old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed
M&L for half brick work with subclass ‘B’ bricks, straight or curved on plan to any radius built in CM 1:4 complete all as specified and directed
Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size n.exc 1.50 Sqm complete all as specified and directed
Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size exc 1.5 Sqm and n.exc 4 Sqm complete all as specified and directed
S&F in repairs Anodised aluminium powder coated frame for doors window,partition and ventilatore with one or more rebates including joining cleat forfixing etc. complete all as specified
S&F in repairs Anodised aluminium powder coated door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified
S&F in repairs Anodised aluminium powder coated window and ventilators shutters sliding or fix type, aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,including provision of lock in each door, rollers, anodised aluminum snap beading screws etc. complete all as specified
S & F sheet glass 5.5 mm thick ordinary quality frosted on one side in n. exc 1.5 Sqm in each pan with rubber beading as in doors and partion.
S&F Prelaminated particle board 12 mm thick, exterior grade,prelaminated both side with decorative choice lamination &other side balancing white lamination,fixed with screws to timber frame work as in aluminium door and partion.
S & F sheet glass thick ordinary quality in n exc 0.75 Sqm in each pan 4 mm thick with rubber beading as in window.
S&F in repair PTMT bath mirror cabinet of overall size 500mmX400mm, fixed in position complete all as specified and directed.
M&L for Factory made solid WPC Door frame (125mm X 63mm Double Rebate) made from 100% LEAD FREE (Single extruded process) material with density 780kg / Cum and manufactured by an ISO : 9001-2015 certified company, all as per specification drawings as directed by the Engr-in-Charge. The door frame should be water proof, Termite proof, Fire retardant and having excellent, fixed with fasters with sufficient holding capacity complete all as specified and directed
M&L for Solid factory made 100% solid WPC brown door frame (100mm X 63mm single rebate) made from 100% LEAD FREE (Single extruded process) material with density 780 kg / Cum & manufactured by an ISO: 9001-2015 certified company, all as per specification drawings as directed by the Engr-in-Charge The door frame should be water proof, termite proof, fire retardant and having excellent, fixed with fasters with sufficient holding capacity complete all as specified and directed .
M&L Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
S & F 35 mm thick factory made flush shutter solid core construction with block board core and ply wood face panels, commercial type both sides complete all as specified and directed.
S & F 0.90 mm thick decorative laminates surface finish one side,colour and pattern as approved,fixed with approved adhesive as per manufacture instructions complete all as specfied and as directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples complete all as specifed and directed
S&F 200mm Stainless steel,barrel tower bolts of extruded section and fixed complete all as specified and directed
S&F 250mm Stainless steel, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed
S&F 150mm Stainless steel handles, cast type, anodised complete all as specified and directed
S&F 150mm Stainless steel barrel tower bolts of extruded section complete all as specified and directed.
S&F 150mm size floor door stopper of Stainless steel and tongue with hard drawn steel spring spring, fixed in floor complete all as specified and directed
S&F mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed
Dismantling of boarding of any type/size as in CB/wardrobes or fixed in any position in hardware (if any) etc complete all as specified
S&F 18 mm thick with min density 600 Kg/Cum LEAD FREE PVC Celuka ply of both side plain white colour fixed with screws, solvent cement/ adhesive to make kitchen/bed rooms cabinet and cupboard shutters and shelves complete as per manufacturer’s specifications complete all as specified and directed
S&F Auto closing hinges 35mm of 0 crank( KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinet shutters complete in all respect and fixed in position all as specified
S&F Ball bearing runners 400 mm Telescopic (KA 5632) full extension load capacity 45 kgs complete all as specified and directed .
S&F D-type cabinet handles premium quality, stainless steel 304/gloss chrome/SN finished 150mm long matt finished complete fixed in position all as specified.
S&F Ball catchers 304 grade stainless steel finished suitable for cabinets premium quality complete fixed in position as per manufacturer's instructions all as specified.
S&F Stainless Steel 304 grade wire Basket of pull out type like lain/cup &saucer /bottle/ multi purpose/2-3 shelf baskets etc for kitchens of required suze complete fixed in position complete all as specified and directed.
S&F in repair for stainless steel, 25 mm dia and 1.2 mm thick curtain rod with and including fixing SS brackets and decorative type brass knobs both side of each rod, complete all as specified and directed Note Measurement will be taken between end points of Knobs
Dismantling wrought iron or mild steel work of any description complete all as specified and as directed..
S&F Rolled mild steel work of Fe-290 (Gde E-165) as in framed work, trussed, purlins, crane gantries, railS&Fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L for Non skid coloured ceramic tiles of any design and pattern, 8 to 9 mm thick (square / rectangular) area of each tile exe 0.18 sqm but not exe 0.36, in floor etc incl 15mm thick screed bed in CM 1:6, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles complete all as specified and directed
M & L for coloured glazed ceramic tiles of any design and pattern, 350x 250x 7mm/ 450X 350X 7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match incl 10 mm thick rendering in CM 1:4, complete all as specified and directed.
M&L Light shade vitrified tiles Double charge 8-9mm thick (Square/Rectangular) polished grade-4, area of each tiles exc 0.36 sqm but n.exc 0.72 sqm , over and including 15mm thick screed bed in Cement mortar (1:6) in flooring, set and jointed in neat cement slurry and pointed in cloured cement to match complete all as specified and directed directed by Engr-in-Charge
M&L Light shade vitrified tiles Double charge 8-9 mm thick (Square/Rectangular) polished grade-4, area of Each tiles exc 0.36 sqm but n.exc 0.72sqm as in skirting/dado, over and including 10mm thick screed bed in Cement mortar (1:4) in flooring, set and jointed in neat cement slurry and pointed in cloured cement to match complete all as specified and directed directed by Engr-in-Charge
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.50mm graded stone aggregate) as in sub base of floor complete all as specified and directed
Taking down cement plaster of any description on brick work or stone masonry walls including rackingout joints, hacking for key, scrubbing down with water etc complete all as specified and directed
M&L 15mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed
M & L plastering in two layers consisting of 10mm thick in CM 1:6 and top layer of 5mm thick in CM 1:4 mixed with liquid water proofing compound on fair faces of brick work or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed. (WPC shall be measured and paid seperately)
M&L for two coats of oil bound distemper over a coat primer to newly plastered surface including preparation of surfaces complete all as specified and directed
M&L Complete removal of existing treatment to wall (internal) surfaces in any height for two coatss of oil bound distemper on walls over a coat of primer to old plastered surface complete all as specified and directed.
Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new/old surfaces complete all as specified and directed.
M&L 5mm thick rendering in ceiling of cement mortar (1:3) on fair faces of brick work or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed
M&L for three coats of white wash to newly plastered surfaces of ceiling including preparation of surfaces, complete all as specified and directed
M&L for preparing new steel and iron surfaces of any description over 10 cm Width /Girth and applying two coats of synthetic enamel paint of any tint over one coat of red oxide primer complete all as directed
M&L for preparing new wooden or wood based surfaces of any description over 10 cm Width /Girth and applying two coats of synthetic enamel paint of any tint over one coat of pink primer complete all as directed
M&L PCC 1:5:10 type E-2, using 40 mm graded concrete, as in foundation, mass concreting, sunken floor etc complete all as specified and directed
M&L PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate, as in gable wall, sunken, coping portion rounded chamfered on edge complete all as specified and directed
Taking up or down 15mm dia steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed
S&F 15 mm bore dia of medium grade galvanised steel tubing with all fittings including tank nipple and fixed complete to wall or laid in floor including cutting through walls, floors, etc and their making good with existing surface complete in all respect as specified
Cutting chases, pinning in, making good to facing where required and pointing in Cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water pipe etc and making good, cutting not exc 10cm width or girth complete all as specified and directed
Taking up or down 20mm dia steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed
S&F 20mm dia bore GI tubing medium grade fixed to wall or ceiling or laid in floors etc complete all as specified and directed
S & F in repair 110 mm bore PVC (SWR) Soil, waste and vent pipes (6 Kg / Sqcm pressure rating) (single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR) Soil, waste and vent pipes , single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F in repair 75mm dia PVC (SWR) multi floor trap with grating including jointing with solvent cement including fixing waste pipe etc complete all as specified and directed
S&F in repair PVC (SWR) bend any radius 110mm bore complete all as specified and directed
S&F in repair PVC (SWR) bend any radius 75mm bore complete all as specified and directed
S&F in repair PVC (SWR) 'P' Traps 110mm bore complete all as specified and directed
S&F in repair PVC vent cowls 110mm complete all as specified and directed
S&F in repair PVC connection 15mm bore dia 450mm long with 2 Nos PTMT nuts with washer complete all as specified
S&F in repair PVC waste pipe 32/40 mm dia complete all as specified and directed
S&F in repair 20 mm dia brass CP tubular towel rail D type 600mm long complete all as specified and directed
S&F in repair 15mm dia brass chromium plated Bib tap fancy type with wall flange complete all as specified
S&F in repair 15mm Stop valve/angle cock fancy type, chromium plated with long shunk and cup (concealed type) high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified
S&F Wash basins, Vitreous China (flat back) 550x400mm ,counter top including of fixing of supply and waste pipe complete all as specified and directed.
S&F in repair of sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm and bowl size 410mm x 330mm x160mm complete all as specified
S&F vitreous china wash down water closed pan with connected flushing cistren white, including connection to drain (or out going pipe) and to flush pipe, antisypthonic and flush pipe) complete all as specified and directed.
S&F in repair 15mm dia brass CP wall mixer with provision for over head shower for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F in repair 15mm dia brass CP sink mixer with swinging spout (wall mounted model) with connecting legs and wall flanges screwed down for iron pipe and fixed complete all as specified and directed .
S&F in repair 15mm dia chromium plated central hole wash hand basin mixer without PWS with 450mm BRAIDED HOUSE hose screwed down high pressure screwed for iron pipe completed all as specified and directed .
S&F in repair CP health faucet with 1m flexible tube and wall hook complete all as specified and directed.
S&F in repair CP overhead shower 100mm round shape single flow (ABS body chromium plated with gray face plate) with rubit cleaning system fixed in 15mm bore of pipe complete all as specified and directed .
S&F in repair CP toilet paper holder fixed to wall with CP brass screws complete all as specified and directed.
S&F in repair sheet glass assembly fancy type 600mm long and fixed with brass screw complete all as specified and directed.
S&F in repairs PVC water storage tank triple layer white colour cylindrical, vertical with closed top with threaded cover hoisted and fixed in position tank capacity 1000 Ltr with and including ball valve high pressure of PTMT with epoxy coated Aluminum rod and high density plastic ball screwed for 20mm bore of iron pipe and making connection for inlet and outlet including dismantle of old water tank and removing from site complete all as specified and directed
S&F in repair 20mm dia gun metal gate valve with iron wheel haeded screwed both ends to iron pipe and fixed complete all as specified and directed
M&L for post construction Antitermite treatment Along the wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in apron complete all as specified and directed
S & F Stainless steel kitchen plate rack 1.0 mm thick sheet of over all size 750 x 900 x 250 mm fixed with steel screws and steel rawal plugs complete all as specified and directed.
M & L butt hinges of mild steel medium weight cold rolled 100mm long and fixed with screws to timber frame work complete all as specified and directed
M & L 16 to 18 mm thick pre polished granite stone slab of approved quality on cooking platform over and incl 20mm thick cement mortar in 1:6, bedded and jointed with cement mortar and pointed in white cement mortar 1:2 complete all as specified and directed.
S & F in repair corner self 300mm radius of 5mm thick toughened glass with CP railing with bracket S & Fixed with brass screw complete all as specified and directed .
M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in surface channel or drain or benching in manhole complete all as specified and directed
M&L for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/stopped ends etc complete all as specified and directed
Dismantling asbestos cement (corrugated, semicorrugated etc) sheets in roof coverings including ridges etc complete all as specified and directed
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified. as specified.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, ridge etc fixed with self tapping screws as specified
S&F Joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated conforming to Fe-410W (gde E-250) quality A complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with screw
Supply and fixing of armstrong ceiling system with fine fissured edge tiles having humidity resistance (RH) of 95%, NRC 0.34 light reflectance approx 84% Thermal conductivity K=0.052 - 0.057. W/mk colour white fire performance of class-I as per BS 476 part 6 & 7 in module size of 600 x 600 x 16 mm thick suitable ofr green building appliation with recycled content of 38-41% with Armstrong silhouette profile exposed grid system with 15 mm white flanges incorporating 6 mm central reveal in white/black colour. Silhoutte, main runners & cross tees to have mitred ends & birdsmouth notches to provide mitred cruciform junctions. The Tee sections have a galvanising of 170 gms per sqm & passed through 500 hrs of salt test. The main runner spaced at 1200 mm c/c should be securely fixe to the structural soffit using Armstrong suspension system at 1200 mm maximum c/c. The first/last Armstron suspension system at the end of each main runner should not be greater than 450 mm from adjacent wall. Cross Tees 1200 mm long should be interlocked between main runners at 600 mm c/c to form 1200 x 600 mm module. 600 x 600 mm module is fortned by fitting 600 mm long flush fitting cross Tees, Perimeter trim consist of Armstron wall angles of size 3000 x 19 x 19 mm secured to walls screws at 450 mm c/c
Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh, with and including provision of necessary frame work as in false ceiling,two coat of distemper over a coat of alkali based primer and a coat of putty making even and smooth surface complete all as specified and directed.
S & F in repairs 12mm thick wave free toughened clear glass as in doors and partitions with stainless steel spider fitting, fish mouth channel in bottom and top as required with and including provision of all other neccessary fixture,sun control film and accesaries, complete all as specified and directed.
M&L for rubber moulded coloured glossy finished cement concrete Chequered tiles of size 30 cm x 30 cm x 20mm thick, jointed in neat cement slurry and pointed in white or coloured cement and pigment to match the surface of tile as in path/ hard standing over and including 15mm thick screed bed in Cement mortar (1:4), including demolition of old PCC/ chequerred tiles complete all as specified and directed.
M&L rendering 15mm thick on brick wall or concrete/ Stone surface in cement mortar 1:4 mixed with WPC, finished even and fair without using extra cement complete all as specified and directed by Engr-in-Charge. Note : WPC shall be measured and paid for seperately.
Supply only Liquid Water proofing compound complete all as specified and directed.
M&L rendering 15mm thick on brick wall or concrete/ Stone surface in cement mortar 1:6 finished even and fair without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L rendering 10mm thick on concrete surface of ceiling in cement mortar 1:3 complete all as specified and directed by Engr-in-Charge.
M & L for Plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) mixed with and incl Shali Plast LW+ of STP/Pidilite URP of Dr. Fixit/ smart care of Asian paints and appoved as per manufactures instruction. Before laying concrete surface shall be cleaned and a bond coat of slurry with Shali Crete URP (of STP) or quivalent in Dr Fixit/ Asian Paint with cement to be applied. Alll cracks in slab to be openend in 'V' groove and filled with Shali Fix RMC a Polymer Morter of STP/ equivalent complete all as specified and as directed.
M&L for 10mm thick rendering in CM 1:4 mixed with Liquid water proofing compound on fair faces of brick or concrete surfaces all as directed by Engr-In-Charge. Note :- Liquid water proofing compound shall be measured and paid separately.
M&L for protecting the roof including parapet wall with water proofing coating , complete as specified below: (a) Clean the surface and apply one coat of primer (STP Shali Urethane BTD diluted in water in 1:1 ratio and applied @ 400 gm/sqm OR Dr, Fixit primeseal diluted in water in 2:1 ratio and applied @ 7-8 sqm/ltr) or Smart care of Asian paints and allows to dry for 6 to 8 hrs. (b) Apply first coat of water proofing coating over primer surface (Shali Urethene BTD with non butuminous bleding of STP Ltd. @ 1 Sqm/Ltr without dilution OR Dr. Fixit New Coat without any dilution @ 2 Sqm /Ltr or Smart care of Asian paint as per manufacturer instructions) (c) Lay Non woven fiber glass mesh (Reinforcement of Shali Geo Text 40/50 gsm of size 2.5mm x 2.5mm) or equivalent with overlap of 50 mm on both direction while the first coat is still wet. (d) Apply second coat of water proofing coating as per manufactures instruction after 6-8 hrs of drying of first coat. (e) Apply third coat of water proofing coating (as per manucturer instruction) after 6-8 hrs of drying of second coat The total thickness of 1 to 1.2mm must be achieved after 7 days of air cure. Note : 1) The colour of each coat shall be as directed by GE. 2) The work shall be carried out by authorised applicator only
M&L for preparation of newly plastered surface on internal walls and distempering with Ist quality acrylic distemper (ready mixed) having VOC content less than 50 gms/ ltr of approved manufacturer of required shade and colour complete as per manufacturer's specification two or more coats over and incl wall putty to achieve smooth surface all as specified and directed by Engr-in-Charge.
M&L for preparation of old treated plastered surface on internal walls and distempering with Ist quality acrylic distemper (ready mixed) having VOC content less than 50 gms/ ltr of approved manufacturer of required shade and colour complete as per manufacturer's specification two or more coats over and incl wall putty to achieve smooth surface all as specified and directed by Engr-in-Charge.
M&L for preparation of newly plastered surfaces of exterior wall by and applying two coats of exterior anti fungal acrylic emulsion paint over a coat of exterior water based primer over ext wall putty of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge.
All as per item No.114 above but ceiling surfaces
M&L for complete removal of existing treatment from old decorated surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with dust extraction system for clean environment certified by reputed paint manufacturers, and applying two coats of exterior anti fungal acrylic emulsion paint over a coat of exterior water based primer over ext wall putty of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge.
All as per item No. 116 above but ceiling surfaces Note for item No. 112 to 117:- (i) The surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are demand to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE before application of distemper for each building. (v). The colour / shade will be all as approved by GE. (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor.
Disconnecting the electrification and taking down DBs (any type of SPN DBs) and making good to the disturbed surfaces to match the existing surface all as specified and as directed by EIC. Note - Temporary power supply shall be provided by contractor.
Taking down U/S submain wiring aluminium etc and making good the disturbed surfaces of walls/ floor etc matching with the existing surface.
M&L for sub-main wiring (concealed/ surface) with two single core 6 sq mm FRLSH PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of massinory including 25 mm dia non-metallic PVC conduit fixed in wall including 6 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by EIC.
Taking down carefully aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pedants, regulators, sockets, light fitting etc.. and making good the disturbed surfaces of walls/ floor etc matching with the existing surface all as specified and as directed by EIC.
Material & Labour for following type Point Wiring controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit MMS ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates).
One light point controlled by one switch.
One ceiling fan point controlled by one switch.
One exhaust fan point controlled by one switch.
One 3 pin socket outlet 5 Amps on the same board.
One 3 pin socket out let 5 Amps on the independent board.
One bell point controlled by one bell push
All as per Item No. 122 above but 2.5 Sq mm multi stranded copper conductor with 2.5 Sq mm copper earth continuity wire connected to earth duly complete for one 15A Socket on Independent board all as specified and as directed by EIC.
S&F LED tube light batten 20 watts 4 fts polycarbonate housing, translucent diffuser with LED light source , 2200 lumen, natural white ,surge protection range 2KV, voltage protection range 120-280 VAC, system efficacy not less than 110 Lm/watt for the fitting , power factor>0.95 total harmonic distortation<20% , colour rendering index >80, coefficient colour temp 6500 K, fixed on site with all accessories all as specified and directed.
Supply and fixing in repair LED luminaire 600mm X 600mm, 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glair free light complete with accessries suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
S & F angle lamp holder, PVC Polycab type with back plate suitable for batten fittings complete including fixing of 9/10 watt LED bulb all as specified.
Supply and fixing step socket type modular fan regulator 120/280 V , 100Watt all as specified and as directed.
Supply and fixing modular socket, 6A -2/3 pin combined 2 module ISI marked 230 volts, 50 Hz all as specified and directed by Engr- in-charge.
S & F Switch Modular single pole, one way 6 Amps, 1 module 240 Volts AC all as specified and directed by Engr- in-charge.
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts 50 hz all as specified and directed by Engr- in-charge.
Supply and fixing switch modular , one-way 16Amps, 1 module 240 Volts AC all as specified and directed by Engr- in-charge.
S & F Switch Modular bell push single pole, one way 6 Amps, 1 module 240 Volts AC all as specified and directed by Engr- in-charge.
Supply and fixing door bell ding dong type suitable for 230 Volts, AC, 230 Volts, single pole.
M & L for ceiling rose, surface bakelite, 65 x 50 mm, three terminals all as specified and as directed.
S & F sheet metal enclosures for SPN DB's with double glazed door for incorporating MCBs,IP-43 , 8 way with 200 amps rated busbar, 240 volts, as per IS-8623 all as specified and as directed.
S & F MCBs SPN 32 amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs all as specified and as directed by Engr-in-Charge.
S & F MCB SP, 6 to 32 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs all as specified and as directed by Engr-in-Charge.
M & L for Earthing complete with galvanised steel pipe electrode, 600 x 600 x 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to galvanised earthing lead of 4 mm dia of iron or steel wire all as shown in electrical plate No. 5 all as specified and as directed. Note :- the cost of excavation and earth work PCC pit and CI cover funnel & watering pipe, wiremesh, charcoal dust and common salt shall be deemed included in the unit rate for earthing all as specified and as directed by EIC.
Taking down old unserviceable existing service/UG cable all as specified and as directed by EIC.
Material and labour for XLPE insulated,LT armoured electric cable with aluminium standed conductor 1100 volts grade,cross-sectional area 35 sqmm ,3.5 core laid in trenches/pipes/ducts/wall/boarings with necessary cable lugs and glands,nuts,bolts and washers etc and testing complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all as specified and directed.
Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed
Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed
M & L for brick sub class 'B' 250mm x 115mm x 0.75mm and laid in trenches as in protection of UG cable complete all as specified and directed.
Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed.
M & L for 50mm bore GI pipe (Light grade) laid under road or fixed with pole/wall of culvert as in protection of UG cable incl necessary MS clamp and complete all as specified and directed.
Supply, fabricated and and fixing of street light bracket made out of GI pipe 1.0 Mtr long, 32 mm dia medium grade bent to shape as directed including clamps made out of 40 mm x 6 mm flat for fixing bracket suitable for mounting on wall including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide/primer all as specified and as directed.
M & L for LED Bldg Security light Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
M & L for disconnecting electric supply, taking down fan, cealing cable ends, dismantling blades carefully after unscrewing nuts and bolts of ceiling fan any size from existing position and bringing to AGE E/M store yard for clelaning all dusts, oiling, greasing all as specified and as directed by EIC and refixing the same as in existing place.
S & F decorative type Glaze Wall light inclding 7/9 watt LED (B22) with all necessary fittings complete all as specifed and directed.
S&F DB Power unit MCB protected socket with sheet steel enclosure 20 Amp combo incl 16 amp plug top indicator type for A/C or Geyser
S & F MCB SP, 40 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs all as specified and as directed by Engr-in-Charge.
S&F single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 20A, SP
S&F Exhast fan made out of sturdy Engineering plastic complete with louvers shutter voltage 230V, 50 Hz, 1200/1400 RPM, copper winding, 24 watt, sweep 250mm
S& F Ceiling fan complete with copper winding ,blades ,down rodss,electronic regulastor and accessories 230 v0lt,1200mm sweep,50W inclding fixing arrangements on roof with making good as per existing one as directed
Supply and fix LED street/security light fitting 25 watt housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 240 Volts AC, 50 HZ, consisting of reflective lens wired with approximate driver PF>0.98 having over voltage protection upto 440 volts, including fixed on wall with 02 Nos MS clamp made out of 40 x 6 mm F1 and bracket made out of 32 mm dia light grade GI pipe not less than 0.9 mtr long bend to shape including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volta grade all as specified and as directed by Engr-in-Charge .
Supply and fixing in repair LED luminaire 600mm X 600mm, 35/36 watt, 220V AC Surface type with high efficiency PMMA diffuser soft glair free light complete with accessries suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
M&L for sub-main wiring (concealed/ surface) with two single core 4 sq mm FRLSH PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of massinory including 20 mm dia non-metallic PVC conduit fixed in wall including 6 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by EIC.
S & F vertical load line in sheet metal enclosures MCCB TPN DB's with double door for accomodate the MCCB , 125 A,4P,16 KA as incomer and MCBs SP 40 A -12 NO as outgooing , IP-43 , TPN 4 way with 200 amps rated busbar, 440 volts, as per IS-8623 and making good the disturbed surface of wall and match with the existing surface compelte all as specified and as directed.
S&F MCCB ,125 AMP,4 POLE,16 KA ,Fixed type ,415 volt all as specified and as directed by EIC.
Supply & Laying XLPE insulated armoured heavy duty electric cable , with multi stranded aluminium conductor served with an inner sheathing of PVC type armoured with galvanized steel wire or tape and PVC sheathed 1100 volt grade,nominal cross sectional area 50 Sqmm 3.5 core inclu lugs and heat shrinkable PVC Sleeves on exposed surfaces & teflon tape duly insulated complete laid in trenches, ducts, drawn through pipe across the road/path/alongpoles/wall/floors/equipment etc including jointing and testing complete all as specified and directed by the Engr-in-charge.
Supply and fixing EXHAST FAN ,steel body AC single Phase ,230 volt of 450 mm sweep ,900 RPM, 90 watt or more, heavy duty with louver including making hole on wall as per Exhast fan size with maching in good condition of wall by plastering and exinting colour all as specified and directed by Engr- in-charge.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
M/S VIJAY TRADERS (BID ID -3306209)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .