| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC PATHANKOT | PATHANKOT | PUNJAB | L1 | Accepted-AOC accept | |
| 2 | L2₹13.2 L+₹25,000 (1.92%)Rejected-AOC | L2 | Rejected-AOC reject | |
| 3 | L3₹15.5 L+₹2.5 L (19.1%)Rejected-AOC VILLAGE PO AND TEHSIL DEHRA DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | L3 | Rejected-AOC reject | |
| 4 | Not Admitted-Fee/PreQual/Technical CHANDRONA TEHSIL NOHRADHAR DISTRICT SIRMOUR H P | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹10.4 L
EMD Value
₹20,775
Closing Date
7 Mar 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE
Jal Shakti Division Dehra
Bhambal Panchayat and Paisa
2024_HPIPH_87564_1
DHR-KNG02-728
Open Tender
Civil Works
Lump-sum
180 days
Dehra
Please refer Tender documents.
8 documents required · 8 mandatory
₹400
EE Dehra
₹20,775
1 May 2024
1 Mar 2024
7 Mar 2024
1 Mar 2024
7 Mar 2024
1 Mar 2024
Amount
Construction of RCC over head tank 25000 ltr cap., with 10.00 mtr stagging height from ground level to bottom of dome slab comprising of inlet, scour & over flow pipes as per details given below from ground level to tank including bends of requried degree, confirming to relevants code RCC stair case i/c G.I pipe railing 45cms. wide of usual height as per site requirement, SFRC/MS manhole cover of 500mm dia and weight of frame and cover should not be less than 40 kg., ventilator at top dome with minimum opening of 45x450cms, water level indicator including floats and measuring gauge, lightening conductor with earthing arrangement etc. The RCC over head reservoir shall include randering/plastering of the uneven exposed surface, two coats of snowcem paint and any other component required for the completion of the job to the entire satisfaciton of Engineer-in-charge. The offers shall also include details structural drawing/ design calculations to be approved by the competent authority based on the raft foundation by taking seismic forces in the design calculation expension joints as required at site. The offer shall also include the cost of providing and fixing of GMS/ MS pipe, fittings complete including duck foot bends, puddle collars, expansion joints etc connecting with rising main & distribution main with required length from the edge of foundation and any other component required for the completion of job upto the entire satisfaction of Engineer-in-charge. Dia of pipe arrangement Inlet pipe = 65 mm dia Outlet pipe = 65 mm dia Scour pipe = 65 mm dia
HEMRAJ THAKUR
aman sood
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .