Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹20.6 L+₹52,745.50 (2.63%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tender | |
| 3 | L3₹22.4 L+₹2.3 L (11.6%)Rejected-Finance KORAMANGALATH HOUSE TOMY LANE SOUTH PANAMBILLY NAGAR KADAVANTHRA P O KOCHI 682 020 | KOCHI | ERNAKULAM | KERALA | 682020 | L3 | Rejected-Finance Other than lowest tender | |
| 4 | L4₹22.8 L+₹2.7 L (13.7%)Rejected-Finance 22 1685 ST JACOB CHURCH LANE PAMBAIMOOLA EDACOCHIN ERNAKULAM KERALA 682010 | ERNAKULAM | ERNAKULAM | KERALA | 682010 | L4 | Rejected-Finance Other than lowest tender |
Tender Value
₹24.1 L
EMD Value
₹48,280
Closing Date
2 Mar 2022, 6:00 pmClosed
GE Fort Kochi
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
SPECIAL REPAIRS TO PRE-FABRICATED CABINS (T-241) OF BRISTOW HOUSE AT INS DRONACHARYA UNDER GE FORTKOCHI.
2022_MES_506176_1
8780/E8/GE Fort Kochi
Open Tender
Civil Works
Item Rate
180 days
Fort Kochi
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE Fort Kochi
₹48,280
Yes
7 Jun 2022
5 Feb 2022
4 Mar 2022
5 Feb 2022
2 Mar 2022
18 Feb 2022
Amount
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth, in layers not exceeding 25cm, watering, and removing surplus spoil to a distance not exceeding 50m (soft/loose soil)and making good surface complete all as specified and directed.
dismantling of wrought iron or mild steel work of any description not otherwise provided for
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings.
S&F steel work in tubular trusses, rafters and posts etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 (grade st-240)complete all as specified and directed.
M&L Cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate for foundations, fillings and mass concrete complete all as specified and directed .
S & F structural steel in roof trusses (framed), trussed, purlins, rails and fastenings and heavy bracket framing including distance pieces, cleats etc(F-290 Gde-165) complete all as specified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmentDitto, with riveted, bolted orwelded attachment
Material and labour for preparation of new or previously untreated steel or iron surfaces, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F pre-painted galvalume aluminum zinc coaing GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
S&F pre-painted galvalume aluminum zinc coaing GI based plain sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/valley gutter, fixed with self tapping screws all as specified and as directed.
M&L 15 mm thick screed bedding layers in cement mortar 1:6 for laying floor finishes tiles .
M&L for heavy duty designer paver tiles, 25 mm thick, set, jointed and pointed with neat cement slurry in floors fixed with white cement and pigment complete all as specified.
Material and labour for 75 mm thick PCC (1:3:6) type C2 (using 40mm graded broken stone aggregate) as in sub base complete all as specified and as directed.
Material and labour for 100 mm thick PCC (1:2:4) type B2 (using 40mm graded broken stone aggregate) as in hard standing complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing), removing serviceable tiles to store and rubbish off the premises.
M&L 10 mm thick screed bedding layers in cement mortar 1:4 for laying floor finishes tiles .
Rendering 10 mm thick in CM 1:3 on brick or concrete surfaces , finished fair and even .for receiving wall tiles.
M & L for vitrified ceramic tiles light shade 10mm thick (square or rectangular) polished area of each tile exc .42 sqm and not exc. 1.00 sqm in floor and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade complete all as specified and directed by Engineer - in - Charge.
M&L Joint free non skid ceramic coloured tiles 7 to 8 m thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exc. 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in white or colour to match complete all as specified.
M&L for glazed ceramic tiles, coloured of size 300 x 400/450 x 7 mm thick as in dado/skirting and riser to steps and jointed in neat cement slurry and pointed in white or coloured cement to match complete.
Taking down aluminium chowkats or frames exc. 1.5 Sqm and not exc 4.00 sqm each with shutters (without taking off shutters from the frame).
M&L for powder coated aluminium frame , shutters & sections for doors , windows , ventilators ,Cup boards ,including necessary rubber beading, locking arrangements etc. complete .
Taking down cement plaster of any description on walls including raking out joints, hacking for key scrubbing down with water etc.
M&L for rendering 15 mm thick in two coats (10 mm thick in cement mortar 1:4 and 5 mm thick in cement mortar 1:4) mixed with water proofing compound) on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement. (Note- water proofing compound shall be measured and paid seperately) .
Supply only liquid water proofing admixture.
M&L for plastering in CM 1:6, 10 mm thick on walls finished even and smooth w/o using extra cement.
Complete removal of existing treatment by scrapping wall complete all as specified and directed.
M&L for 2 mm thick wall care putty on walls
M&L for preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of primer.
M&L for preparation of old plastered surface of wall and applying two coats of oil bound distemper over a coat of primer.
M&L for two coats of Antifungal paint (Apex ultima Protek of Asian paint or Equivalent in approved Makes) over a coat of Exterior primer (Proffesional pack of Asian paints) over a coat of external wall care piutty n.exc 2 mm thick on new or old prepared plastered external surfaces and including scafoldings and cradles including hoisting and lowering as required with bracing , support complete all as specified.
Dismanting wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets.
S & F anodised aluminium snap grid frame work of grid size 605 x 605 mm thick for false ceiling complete alll as specified
M & L 4 mm thick non asbestose fibre cement bldg boards fixed or laid or insert to timber or GI or aluminium frame work with screws and applying two coats of OBD over a coat of primer
Demolition of cement concrete of any description and in any position not otherwie specifically provide for.
M&L for broken stone or boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M&L PCC 75 mm thick, 1:3:6 (Type C2) using 40mm graded crushed stone aggregate as in plinth protection.
S & F in repairs vitreous china wash down water closet (Pedestal pattern) white with 'P' trap complete including plastic seat cover white closed pattern with flat bottom, and cover with plastic hinges complete all as specified.
S&F in repairs vitreous china wash basin, white flat back, size 550 X 400 mm excluding taps, fixed to wall by anchor bolts , waste coupling, waste pipe etc complete .
S & F PVC low level flushing cistern 10 Ltr capacity incl float valve and flush pipe complete
S&Fin repairs fancy type pillar taps cast copper alloy, with capstan head, chromium plated, screwed down , high pressure, with or without lettered 'Hot' or Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed. Bore of pipe in 15mm.
S&F in repairs PVC inlet connections 60 cm long, 15 mm bore with PTMT nuts.
S& fix in repairs Towel rail chromium plated, fixed in repairs complete 600mm long
S&F in repairs door closer aluminium (extuded section) body hydraulically regulated designation No 3 universal type suitable for door shutter of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed.
S&F in repairs Health faucet set with flexible hose CP 15 mm including fittings complete fixed in repairs all as specified.
S&F in repairs Toilet paper holder SS fixed in repairs complete all as specified and as directed.
S&F in repairs Stainless steel soap dish fixed with SS screws .
M&L for preparation of old treated wooden surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
S & F in repair 32 mm brass chromium plated bottle traps for washbasins with inlet and outlet screwed for pipe or copnnections including necessary packing,union and cap and fixed complete all as specified
S & F 75 mm PVC (SWR) floor trap with grating including jointing with solvent cement complete all as specified.
S & F in repair Glass shelf 600 MM . Make:- Jaquar or equilant
Taking down copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or taking credit and making good the disturbed surfaces of walls, floors, etc.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface all as specified and directed at site.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting wall/PCC, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :-
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
One bell point controlled by one, bell switch 5 Amps
Description all as per item No 4 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sq mm copper conductor FRLS PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
Description all as per item No. 5 here in before but using 4.0 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket point including necessary running of 4.0 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common eath dolly.
Supply and fix Modular switch 06 Amp, single pole, one way, 230 Volt complete all as specified & directed.
Supply and fix Modular switch 16 Amp, single pole, one way, 230 Volt complete all as specified & directed.
Supply and fix Modular bell push flush, 06 Amp, Volt complete all as specified & directed
S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified
Supply and fix Modular socket outlet 2 in 1, 3 pin, 06 Amp flush type, 230 volt, complete all as specified and directed
Supply and fix modular socket outlet multi purpose 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, 230 volt, complete all as specified & directed.
Supply and fix ding dong bell, AC, 230 volts, single pole complete all as specified & directed
Taking down carefully wall fan of any sweep Each complete with all accessories, dismantling blades and kept in safe custody including painting complete with rewinding using synthetic enamel copper wire and paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and hanging and connecting up with provn of 3 core copper flexible cable of size 1.5 Sq mm from ceiling rose to fan complete all as specified & directed.
Supply and fix in replacement of surface mounted LED tube light fitting four feet long, 22 Watt with IP 20 protection comprises of aluminium extruded channel, extruded aluminium body, integrated electronic driver, etc and all accessories pre-wired including connecting up complete all as directed. Make : Havells Cat part No LUMILINEPLUSBS22WLED865SPCSS or equivalent Crompton / Philips
S & F for lamp holder , PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size Complete.
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc four runs of PVC insulated with 6 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Four runs of 6 sqmm cable, one run of 6 sqmm cable earth and one run of PVC conduit will be measured as one unit
S & F for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCB tripple pole and neutral rated capacity 63Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Supply and fix in repair of MCB, SP, AC, 240 volts of 06 to 32 Amps capacity complete all as specified & directed..
S & F for metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and as directed complete all as specified and as directed
S & F for Ventilation fan of 200 mm sweep made of PVC body complete with louver and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to ventilation fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted).
Taking down carefully air conditioning indoor and outdoor unit complete with all accessories, dismantling and kept in safe custody including refixing the same position with necessary Gas charging and minor repairs/spare parts required if any complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in Set ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel Gl protection pipe 15mm bore light grade all as shown in electrical plate No 3 on serial page No 497 of SSR part 2009 and connected to main switch board / Main DB's including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, Gl pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed.
Taking out old unsv GI pipe 15 mm bore with all connecting accessories complete from wall/ floor as as specified
Taking out old unsv GI pipe 20 mm bore with all connecting accessories complete from wall/ floor as as specified
Taking out old unsv GI pipe 25 mm bore with all connecting accessories complete from wall/ floor as as specified
Taking out old unsv GI pipe 40 mm bore with all connecting accessories complete from wall/ floor as as specified
S&F CPVC pipes, SDR 11, 16 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow ,Tee, bends, unions ,sockets ,Threaded Adoptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and as directed.
S&F CPVC pipes, SDR 11, 20 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow ,Tee, bends, unions ,sockets ,Threaded Adoptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and as directed.
S&F CPVC pipes, SDR 11, 25 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow ,Tee, bends, unions ,sockets ,Threaded Adoptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts/trenches with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and as directed.
S&F CPVC pipes, SDR 11, 40 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow ,Tee, bends, unions ,sockets ,Threaded Adoptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and as directed.
Supply and fix in repair half/quarter turn 15 mm bore bib tap, cast brass chromium plated fancy type with crutch or butterfly handle screwed down screwed for iron pipe short body, complete all as specified and directed (Weight not less than as specified in SSR)
Supply and fix in repair 15mm Stop cock, cast copper alloy chromium plated fancy type with long shank and cup crutch or butterfly handle suitable for CPVC pipe.
Supply and fix in repair 20 mm Stop valves, cast copper alloy chromium plated fancy type with long shank and cup crutch or butterfly handle suitable for CPVC pipes.
Supply and fix Health faucet suitable for ABS Body chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete suitable for working pressures of high rise buildings including taking out old health faucet complete all as specified.
Supply and fix half/quarter turn 15 mm dia Angle cock, cast copper alloy, chromium plated, fancy type with long shank and cup, screwed down high pressure with crutch or butterfly handle, screwed both ends iron pipe suitable for CPVC pipes including taking down old cock,complete all as specified
Supply and fix in repair half/quarter turn 15 mm bore bib tap, cast brass chromium plated fancy type with crutch or butterfly handle screwed down screwed for iron pipe short body, complete all as specified and directed (Weight not less than as specified in SSR)
S&F in repair 25 mm gun metal globe/gate valves, with CPVC body, screwed/pasted both ends for CPVC pipe, complete including taking out old valves all as specified.
S&F in repair 40 mm gun metal globe/gate valves, with CPVC body, screwed/pasted both ends for CPVC pipe, complete including taking out old valves all as specified.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter depth and getting out in soft/loose soil / floor and making good the disturbed surfaces all as directed and specified
Returning and filling of soil including spreading leveling, watering and ramming in layers not exceeding 25 cm .
Removing excavated soil to a distance not exceeding 50 meter , not exceeding 1.5 meter above the starting point and depositing where directed.
M&L PCC 1:4:8 type D-2 (40mm graded agg) in foundation, sub class mass concrete etc all as specified and directed.
Taking down u/s UG cable of any size all as specified and directed
Supply and laying Cable XLPE insulated screened PVC bedded, galvanised steel strip of wire armoured, electric power cables ( Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm, 4 core.
Supply and laying Cable XLPE insulated screened PVC bedded, galvanised steel strip of wire armoured, electric power cables ( Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm, 2 core.
M&L sand cushioning in trenches using fine aggregate for cable cushioning all as specified and as directed. Note : Thickness of sand cushioning after punning down will be measured and paid.
Supply and lay sub class "B" burnt bricks, as in cable protection, laid length of brick perpendicular to length of cable complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (40mm graded agg) in foundation, sub class mass concrete etc all as specified and directed.
Supply and fixing in repair GI tube light grade 40mm dia for fixing floor/trench all as specified and directed.
Supply and fixing LED post of lantern 20 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing LED post of lantern 40 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Material & labour for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in Set ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6mm mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel Gl protection pipe 15mm bore light grade all as shown in electrical plate No 3 on serial page No 497 of SSR part 2009 and connected to main switch board / Main DB's including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, Gl pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed.
Supply and fixing poly carbonate junction box size of 130x180x77 mm IP 66 fixed on pole incl provn of MCB SP 10 Amps fixed on rail inside box with proper hinges locking arrangements with provn of clamping accessories complete incl taking down old unsv item all as specified
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .