Tender Value
₹35.8 L
EMD Value
₹61,200
Closing Date
27 May 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER JAL SHAKTI DIVISION BAGGI
EXECUTIVE ENGINEER JAL SHAKTI DIVISION BAGGI
AS PER BOQ
2022_HPIPH_60757_1
EE-JSD-BAGGI/2022- 8191-8240 DATED 18/05/2022
Open Tender
Civil Works
Item Rate
180 days
BAGGI
AS PER NIT
8 documents required · 8 mandatory
₹800
EE BAGGI
₹61,200
Yes
24 Apr 2023
18 May 2022
28 May 2022
18 May 2022
27 May 2022
19 May 2022
120 days
Amount
Excavation in foundation, trenches ( for pipes & pits) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, blasting soft/ hard rock or chieselling soft/hard rock where blasting is prohibited in all lifts including trimming and dressing of sides, leveling of beds to correct grade i/c shoring /strutting , planking, timbering & dewatering wherever required, stacking the useable & unuseable material /soil separately & after laying jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposoited layer by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts including restoration unmetalled surfaces to its original condition & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of engineer-in-charge.
Providing , laying, jointing testing and carriage , in trenches MS pipe of following dia meters confirming to confirming to BIS :3183-2007,of following grade and having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, providing and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged porationof the pipes and special made from the parent tube shall be provided anticorrossive treatment by applying two coatsof anticorrsive bituminous pait over a priming coat as AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
First Stage :-
80 mm dia -MS Pipe 4.40 mm thickness with FT-38 ( L 290 -X42 Grade)
Providing , laying,jointing ( by way of circumfrential butt welded joints in three layers by electrical arc welding ) and testing of MSERW pipe of following dia meters confirming to BIS 3183-2007, steel grade specified below L290 X42 (latest with upto date amendments) having wall thickness and grade as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, bends etc. as per site requirement made from parent tubes . The laying of pipe shall include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per IS standards . The welding electrodes shall be as per IS 814:2004 of Advani Oerlikon/ L&T or ISI marked make. Negative tolerance in thickness and mass of pipes will not be accepted. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer-in-charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
80 mm dia - MSERW pipe of 4.40 mm thickness F-Table 38 ( L 290-X42 Grade)
Laying, jointing,testing and carriage in trenches GMS pipe of following dia meters confirming to confirming to BIS :1239 (Part-1), of following grade and having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, providing and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
Second Stage :-
80 mm dia -GMS Pipe 4.80 mm thickness (Heavy Class) Flange Table-34
Laying, jointing,testing and carriage ( by way of circumfrential butt welded joints by electrical arc welding ) and testing of GMS pipe of following dia meters confirming to BIS 1239 (Part-1), grade specified below (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, bends etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
First Stage :-
80 mm dia -GMS Pipe 4.00 mm thickness (Medium Class)
Second Stage :-
80 mm dia -GMS Pipe 4.80 mm thickness (Heavy Class)
80 mm dia -GMS Pipe 4.00 mm thickness (Medium Class)
CENTRIFUGAL STAGE (Stage1st ):-Providing horizontal spindle,horizontal/redial split casing/end suction(Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements:
SITE CONDITIONS :-Location of site:- About 45 Km from Baggi The altitude of place in which the motor is intended to work in ordinary service if it exceeds 1000 mtr. Altitude of place is 1700 m above MSL Humidity : Weather generally remains humid during monsoon season Nature of atmosphere : As normally encountered in Shivalik Range. Detail of quality of water Clear cold water. Water free from sand or not Yes Water corrosive or not No Turbidity (if any) Clear Cold water Depth during HFL in the pond N.A. Max draw down ----Mtr. Depth of well . Any other information or requirement Rising main Dia:- 100mm and total length is 75 mtr. B.OPERATING CONDITIONS Type of current AC three/single phase Operating frequency 50 HZ Rated voltage 400 (+/-) 10% volts System of earthing if any to be adopted.Double loop earthing as per BIS 3043-1987 latest with upto date ammendments No. of working hours per day 8 hours Speed of revolution in RPM To be quoted by tenderer Direction of rotation To be quoted by tenderer The max. Temp. of cooling air & water in the place in which the pumpset is intended to work in ordinary service. 35 degree centigrade. C. MOTOR Ref to BIS code BIS 325-1978 read with BIS 900-1992 (latest) with up to date amanedments. Type of enclosure of motor SPDP (As per BIS 4691-1985, latest). Type of duty Continuous
Mechanical out put in KW Suitable for driving cenrifugal pumps required for duties specified against pumps.To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. Class of insulation Class -B/F- Max.permissible temp.rise of motor reqd. if different from that given in B (viii) above To be specified by the tenderer Particulars of test reqd. & where they are to be conducted. As per terms & conditions attached Particulars as to whether voltage limiting device will be employed ATS / Star Delta starter oil immersed,fully automatic to be installed between bus bar chamber & motor.Shunt capacitor is also proposed to be installed for improving the power factor at site. NOTE:- Star delta starter upto 37.5 KW & ATS for 37.5 KW to 50 KW & stator rotor starter with slip ring motor beyond 50 KW. Motor whether squirrel cage or slipring Squirrel cage. Note: Squirrel cage up to 65 HP & slipring above 65 HP Details of shaft extension required. Just sufficient to provide direct drive by flexible coupling to pump. Type of slipring gear whether continously rated or for starting purposes only and whether to be fitted with brush lifting or short circuiting arrangements or both if interlocks are required.Continously rated for squirrel cage/ slippering motor. Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit. Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current. Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No.of starts during a specified period. To work the pump offered Where possible fault capacity of the system to which the motor is connected. The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.
PUMPS: BIS: 1520-1980, read with BIS 9137-1978 both latest with up to date amendments. Nos of pumps reqd.1 No. pumps Spare parts required For two years normal maintenance as recommended by manufacturer. Optional fittings reqd.Air cock for exhausting air from each stage E. PUMP OPERATING CONDITIONS Capacity 4.96 LPS/for Each pump Total head in Mts.578 Mtrs.( If total head is not known then following details be provided) :- Static head 578 Mtrs Minimum depth of water ………….. Mtrs. Variation in water level ………….. Mtrs. Ground level to max. water level '--------1732 Mtrs. Ground level to delivery point 2310 Mtrs. Pressure in the suction tank …………. Kg/cm^2 Pressure in the delivery tank …………. Kg/cm^2 Length of R/Main - 2250 mtrs ( column pipe +Rising main) Dia of R/Main 80 mm Dia (MC) Drive arrangement: Direct through flexible coupling on a common base plate.Drive type Electric driven NPSH required To be quoted by contractor. Limits of total head in which the pump is reqd. to operate. (-) 25% to (+) 10% of total head. Suction/delivery size of pump To be specified by the tenderer Efficiency of pump at To be specified by the tenderer a) Duty head b) (+) 10 % head c) (-) 25 % head Material of construction To be specified by the tenderer (Manufacturer's certficate to be appended)
Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL.
Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.6 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities
a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments
b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.
c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)
e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments
f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments
g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments
h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments
i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments
k) Capacitor of Mechneil/ BHEL/GEC make as per 1S:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P.offered including cables as per relevant ISI code (of siemens/clocter/IEC make ) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS:4064:1978 with upto date ammendments
l) Providing suitable oil immersed starter delta/direct on line/auto transformer/starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments
m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)
n) Providing antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971.
Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/GLED/Kilburn Fourses / Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments
Providng double flanged cast steel sluice valves ASA-300 of leader/BHEL Kirlosker/Kilburn GLED/fourses make and one step higher then delivery line of pump and capable of withstanding the normal seat pressure and as per BIS standards with upto date ammdnements
Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLED/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)
Providing double flanged cast steel reflux valves class ASA-300 of Leader/BHEL/KILROSKER/ Kartar/KILBURN/GLED/ FOURSES make and of 65 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments.
Providing 100 mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per IS:2373:1981 with upto date ammendments
Installation of all the items apparing as per the systematic drawing .
Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3 mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated . The size of the various components to be as under:
a) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5 M/second in the suction pipe
b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe
c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thimbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.
Motor side (From switch to starter and starter to motor)
Supply side (From Meter of HPSEB to bus bar and switch)
Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
CENTRIFUGAL STAGE (Stage 2nd ):- Providing horizontal spindle,horizontal/redial split casing/end suction(Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements:
SITE CONDITIONS :-Location of site:- About 45 Km from Baggi The altitude of place in which the motor is intended to work in ordinary service if it exceeds 1000 mtr. Altitude of place is 2300m above MSL Humidity : Weather generally remains humid during monsoon season Nature of atmosphere : As normally encountered in Shivalik Range. Detail of quality of water Clear cold water. Water free from sand or not Yes Water corrosive or not No Turbidity (if any) Clear Cold water Depth during HFL in the pond N.A. Max draw down ----Mtr. Depth of well . Any other information or requirement Rising main Dia:- 100mm and total length is 75 mtr. B.OPERATING CONDITIONS Type of current AC three/single phase Operating frequency 50 HZ Rated voltage 400 (+/-) 10% volts System of earthing if any to be adopted.Double loop earthing as per BIS 3043-1987 latest with upto date ammendments No. of working hours per day 8 hours Speed of revolution in RPM To be quoted by tenderer Direction of rotation To be quoted by tenderer The max. Temp. of cooling air & water in the place in which the pumpset is intended to work in ordinary service. 35 degree centigrade. C. MOTOR Ref to BIS code BIS 325-1978 read with BIS 900-1992 (latest) with up to date amanedments. Type of enclosure of motor SPDP (As per BIS 4691-1985, latest). Type of duty Continuous
Mechanical out put in KW Suitable for driving cenrifugal pumps required for duties specified against pumps.To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. Class of insulation Class -B/F- Max.permissible temp.rise of motor reqd. if different from that given in B (viii) above To be specified by the tenderer Particulars of test reqd. & where they are to be conducted. As per terms & conditions attached Particulars as to whether voltage limiting device will be employed ATS / Star Delta starter oil immersed,fully automatic to be installed between bus bar chamber & motor.Shunt capacitor is also proposed to be installed for improving the power factor at site. NOTE:- Star delta starter upto 37.5 KW & ATS for 37.5 KW to 50 KW & stator rotor starter with slip ring motor beyond 50 KW. Motor whether squirrel cage or slipring Squirrel cage. Note: Squirrel cage up to 65 HP & slipring above 65 HP Details of shaft extension required. Just sufficient to provide direct drive by flexible coupling to pump. Type of slipring gear whether continously rated or for starting purposes only and whether to be fitted with brush lifting or short circuiting arrangements or both if interlocks are required.Continously rated for squirrel cage/ slippering motor. Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit. Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current. Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No.of starts during a specified period. To work the pump offered Where possible fault capacity of the system to which the motor is connected. The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.
PUMPS: BIS: 1520-1980, read with BIS 9137-1978 both latest with up to date amendments. Nos of pumps reqd.1 No. pumps Spare parts required For two years normal maintenance as recommended by manufacturer. Optional fittings reqd.Air cock for exhausting air from each stage E. PUMP OPERATING CONDITIONS Capacity 5.70 LPS/ for each pump set Total head in Mts.447 Mtrs.( If total head is not known then following details be provided) :- Static head 447Mtrs Minimum depth of water ………….. Mtrs. Variation in water level ………….. Mtrs. Ground level to max. water level '------------------- Mtrs. Ground level to delivery point 2755Mtrs. Pressure in the suction tank …………. Kg/cm^2 Pressure in the delivery tank 2308. Kg/cm^2 Length of R/Main -2150 mtrs ( column pipe +Rising main) Dia of R/Main 80 mm Dia Drive arrangement: Direct through flexible coupling on a common base plate.Drive type Electric driven NPSH required To be quoted by contractor. Limits of total head in which the pump is reqd. to operate. (-) 25% to (+) 10% of total head. Suction/delivery size of pump To be specified by the tenderer Efficiency of pump at To be specified by the tenderer a) Duty head b) (+) 10 % head c) (-) 25 % head Material of construction To be specified by the tenderer (Manufacturer's certficate to be appended)
Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL.
Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities
a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments
b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.
c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)
e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments
f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments
g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments
h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments
i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments
k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments
l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments
m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)
n) Providing antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971.
Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/GLEd/Kilburn Fourses / Kartar make and equal to dia of suction pipe and cpable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments
Providng double flanged cast steel sluice valves ASA-300 of leader/BHEL Kirlosker/Kilburn GLED/fourses make and one step higher then delivery line of pump and capable of withstanding the normal seat pressure and as per BIS standards with upto date ammdnements
Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/ Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)
Providing double flanged cast steel reflux valves class ASA-300 of Leader /BHEL/KILROSKER/ Kartar/ KILBURN/GLED/FOURSES make and of 65 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments.
Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/ precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments
Installation of all the items apparing as per the systematic drawing .
Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated. The size of the various components to be as under:
Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe
Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe
Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.
Motor side (From switch to starter and starter to motor)
Supply side (From Meter of HPSEB to bus bar and switch)
Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Bharat Engg and Suppliers
SANGRAM NAIK
KUSHAL SINGH RAGHAV
competent associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .