| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹42.0 L+₹24,800 (0.59%)Rejected-Finance MAKKIL HOUSE MUNDAMVELI POST MOOLAMKUZHI KERALA KOCHI 682 507 | ERNAKULAM | KERALA | 682507 | L2 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
29 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2023_MES_604131_1
GE MAINT EZHIMALA 8580
Open Tender
Civil Works
Item Rate
330 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹90,000
Yes
22 Aug 2023
19 Jun 2023
31 Jul 2023
19 Jun 2023
29 Jul 2023
3 Jul 2023
20 Jun 2023 - 27 Jun 2023
Amount
Notes:- (i) The scope of work is to be carried out from ground level to nearly upto 40 metres of height. (ii) Quoted rates are deemed to be inclusive of using mechanical means for surface preperation and application of paint as per manufacturer's instruction all as specified and directed by Engg-in-Charge. (iii) Quoted rates are deemed to be inclusive for scaffolding as required. Contractors should arrange necessary scaffolding and all safety precautions for workers at the time of carrying out works as described in Sch 'A'/ BOQ. (iv) Contractor should visit the site before quoting the tender to assess the resources required to execute the work as the site include prestigeous buildings of INA.
Dismantling the existing water tank and S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 500 litres complete all as specified and as directed.
Dismantling the existing water tank and S&F rotational moulded polyethylene water storage tanks cylindrical vertical / loft rectangular type with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 1000 litres complete all as specified and as directed.
Dismantling the existing water tank and S&F rotational moulded polyethylene water storage tanks (cylindrical vertical / loft rectangular type with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 2000 litres complete all as specified and as directed.
Cleaning and removing all scales and dirts etc from tanks and from mouths of circulating pipes etc. of capacity exc 250 and n.exc 500 ltrs complete all as specified and as directed. Note:- The tanks are at upto height of 20 mts from ground level or inside forest area / non accssable areas (site clearance to be done to reach water tank where ever required), if breakage of float valve / rusted pipes / rusted gate valves to be replaced with own cost, cleaning of tank using bleaching powder and washed with water.
Cleaning and removing all scales and dirts etc from tanks and from mouths of circulating pipes etc. of capacity exc 500 and n.exc 1000 ltrs complete all as specified and as directed. Note:- The tanks are at upto height of 20 mts from ground level or inside forest area / non accssable areas (site clearance to be done to reach water tank where ever required), if breakage of float valve / rusted pipes / rusted gate valves to be replaced with own cost, cleaning of tank using bleaching powder and washed with water.
Cleaning and removing all scales and dirts etc from tanks and from mouths of circulating pipes etc. of capacity exc 1000 and n.exc 2000 ltrs complete all as specified and as directed. Note: The tanks are at upto height of 20 mts from ground level or inside Forest area / Non accssable areas (site clearance to be done to reach water tank where ever required), if breakage of float valve / rusted pipes / rusted gate valves to be replaced with own cost ,cleaning of tank using bleaching powder and washed with water.
Taking down defective/damaged water storage tank cover and supply & fix polyethylene tank cover with necessary locking arrangement complete all as specified and as directed at site.
M&L for writing letters or figures(Block, Romn, Italic or Indian) not exceeding 30 cm high including writing stops, commas, short lines, dashes, hyphen, brackets etc complete all as specified and as directed. Ex:- "TANK-CLEANED-ON DD/MM/YYY"
S&F in repairs 20 mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed to existing pipe complete all as specified and as directed.
S&F in repairs 25 mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed to existing pipe complete all as specified and as directed.
S&F in repairs CPVC gate valve 25 mm fixed to new or old pipe complete all as specified and as directed.
S&F in repairs CPVC gate valve 32 mm fixed to new or old pipe complete all as specified and as directed.
Taking up or down steel tubing and connections, 20mm dia complete all as specified and as directed.
Taking up or down steel tubing and connections, 25/32 mm dia complete all as specified and as directed.
Supplying and laying of 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and laying of 25 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and laying of 32 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
M&L for preperation of old decorated surfaces and applying one coat of sandtex matt finish on wall complete all as specified and as per manufacturer's instructions.
M&L for preparation of old treated ceiling surfaces and applying one coat of white wash on ceiling complete all as specified and as directed.
M&L for preparation of old treated celling surfaces and applying one coat of oil emulsion distemper complete all as specified and as directed.
M&L for preparation of old decorated wall surfaces and applying one coat of oil bound distemper complete all as specified and as directed.
M&L for preparation of old treated surfaces and applying one coat of acrylic emulsion paint (interior grade) on wall complete all as specified and as per manufacturer's instructions.
M&L for complete removal of existing treatment and applying two coats of acrylic emulsion paint (interior grade) on wall over a coat of acrylic primer over a coat of putty complete all as specified and as per manufacturer's instructions.
M&L for preparation of old treated surfaces and applying one coat of acrylic emulsion paint (interior grade) on ceiling complete all as specified and as per manufacturer's instructions.
M&L for preparation of old treated surfaces and applying one coat of acrylic emulsion paint (exterior grade) on wall complete all as specified and as per manufacturer's instructions.
M&L for preparation of old painted steel/iron surfaces exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of epoxy paint complete all as specified and as directed.
M&L for preparation of old treated surfaces of floor/wall and applying one coat of terracotta paint complete all as specified and as directed.
M&L for french polishing on surfaces of any description, width or girth including cleaning and preparing the surfaces including a coat of wood filler on old works with one or more coats complete all as specified and as directed.
M&L for preparation of old treated mangalore pattern roof tile surfaces by cleaning with by wire brushes to remove all existing fungal growth etc and applying one coat of antifungal paint complete all as specified and as directed and as per manufacturer's instructions.
M&L for preparation of old treated wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for removing shrubs, vegetation, roots etc.. from external wall surfaces, by dismantling brick work, RCC or taking down plastering as the case may be, including dismantling SWR pipes, OH PVC service tanks etc and refixing the same in original position and making good the surface dismantled complete all as specified and as directed by EIC. Note:- Area to be dismantled exc 1 Sqm and not exc 3 Sqm.
M&L for treating holes, cracks etc. up to 10mm by making V groove using patti blades and filling the cracks with ready to use crack fillers and allowed to dry complete all as specified and as directed.
M&L for preparation of external wall surfaces by scrubbing using nylon/jute/wire brushes/scrapper blades or by using sanding machine to remove algae, moss, fungus and loosely adhered particles like dust, efflorescence etc. and washing the surfaces with pressure jet washers and surface allowed to dry complete all as specified and as directed.
M&L for application of one coat of primer with sealant properties using Seal - O - Prime or Weather coat exterior primer (of Asian Paints/Berger/Nerolac or equivalent in other make ) complete and allowed to dry overnight to receive first coat of emulsion paint complete all as specified and as directed. Note:- Before application of the priming coat the moisture of the wall surface shall be checked and shall be not less than 12 % when checked with a moisture meter.
M&L for application of first coat of exterior emulsion paint weather coat smooth (Asian Paints/Berger/Nerolac or equivalent in other make) on primed wall surface using rollers made from foam or synthetic fibres to get a smooth and tint free surfaces complete all as specified and as directed by EIC and allowed to dry for at least 8 hrs / over night to receive second coat of emulsion paint.
M&L for application of second coat of exterior emulsion paint weather coat smooth (Asian Paints/Berger/Nerolac or equivalent in other make) on wall surfaces using rollers made from foam or synthetic fibres to get a smooth and tint free surfaces complete all as specified and as directed by EIC.
Johnson Raiju
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .