| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.0 LAccepted-AOC NEAR TELEPHONE EXCHANGE BIJROL ROAD BARAUT U P PATEL NAGAR BARAUT 250611 DISTT BAGHPAT | BAGHPAT | UTTAR PRADESH | 250611 | ₹29.0 L | L-1 | Accepted-AOC Lowest Bid |
| 2 | L-2₹40.0 L+₹11.1 L (38.2%)Rejected-Finance B 43 CIVIL LINES 1ST FLOOR NAYAPURA KOTA RAJASTHAN 324001 UDYAM RJ 24 0019224 08ABKPA3675N1Z9 R M | KOTA | RAJASTHAN | 324001 | ₹40.0 L+₹11.1 L (38.2%) | L-2 | Rejected-Finance Higher Bid |
| 3 | Not Admitted-PreQual/Technical NEAR DFO OFFICE VIDYA NAGAR MEHAM ROAD BHIWANI 127021 | BHIWANI | BHIWANI | HARYANA | 127021 | - | - | Not Admitted-PreQual/Technical Others-Not meet TQR and FQR |
| 4 | Not Admitted-PreQual/Technical | - | - | Not Admitted-PreQual/Technical Others-Not meet TQR and FQR |
| 5 | Not Admitted-PreQual/Technical LANE NO 03 PRAGATI VIHAR RISHIKESH | - | - | Not Admitted-PreQual/Technical Others-Not meet TQR |
| Sl No | Description | Qty | Unit | M/s Singhal and Co L2 | M/S AJAY TOMAR CONTRACTOR L1 |
|---|---|---|---|---|---|
| 1.00 | 220KV SUBSTATION PIRAN KALIYAR
Following work to be carried out for preventive maintenance on quarterly basis of 2 No. of 220/132kV 100 MVA T/F:
1. Checking of oil level in main & OLTC conservator tank and bushings.
2. Attending minor oil leakage/seepage from main body/conservator tank/radiator of transformer by tightening.
3. Tightening of all bushing clamps & repacement of damaged/defected clamps and connectors.
4. Rectification of electrical fault of auto/manual operation of cooling fans by replacement of electrical equipment like contactor, MCB, relay etc.
5. Tightening of neutral and main body earthing.
6. Cleaning and washing of transformer main tank/radiator etc.
7. Tightening of all electrical connections in transformer marshalling box & applying CRC.
8. Testing of WTI, OTI, buccholz relay and PRV.
9. Any other work as per site requirement of as per direction of site incharge. | 8 | Job | 4,500 ₹36,000 Lowest | 6,000 ₹48,000 |
| 2.00 | Following work to be carried out for preventive maintenance on quarterly basis of 2 No. of 220/33kV 50 MVA T/F:
1. Checking of oil level in main & OLTC conservator tank and bushings.
2. Attending minor oil leakage/seepage from main body/conservator tank/radiator of transformer by tightening.
3. Tightening of all bushing clamps & repacement of damaged/defected clamps and connectors.
4. Rectification of electrical fault of auto/manual operation of cooling fans by replacement of electrical equipment like contactor, MCB, relay etc.
5. Tightening of neutral and main body earthing.
6. Cleaning and washing of transformer main tank/radiator etc.
7. Tightening of all electrical connections in transformer marshalling box & applying CRC.
8. Testing of WTI, OTI, buccholz relay and PRV.
9. Any other work as per site requirement of as per direction of site incharge. | 8 | Job | 4,500 ₹36,000 Lowest | 6,000 ₹48,000 |
| 3.00 | Following work to be carried out for preventive maintenance of 220kV Bays (CB, CT, PT, LA, Isolator & Wave trap) on quarterly basis (8 Bays x 4 times = 32)
1. Tightening of clamps & connectors and replacement of the same if found damaged/defective.
2. Cleaning of Porcelain insulator and checking of damage.
3. Replacement of rusted nuts/bolts of CT, PT, LA, CVT etc..
4. Top up of oil after checking oil level in CT/PT/CVT.
5. checking of healthiness of surge arrestors.
6. Apply CRC in junction boxes of CT, CVT etc.
7. Checking & tightening of equipment earthing.
8. Any other work as per site requirement of as per direction of site incharge. | 32 | Job | 2,500 ₹80,000 Lowest | 6,000 ₹1,92,000 |
| 4.00 | Following work to be carried out for preventive maintenance of 132kV Bays (CB, CT, PT, LA, isolator & Wave trap) on quarterly basis (5 Bays x 4 times= 20)
1. Tightening of clamps & connectors and replacement of the same if found damaged/defective.
2. Cleaning of Porcelain insulator and checking of damage.
3. Replacement of rusted nuts/bolts of CT, PT, LA, CVT etc..
4. Top up of oil after checking oil level in CT/PT/CVT.
5. checking of healthiness of surge arrestors.
6. Apply CRC in junction boxes of CT, CVT etc.
7. Checking & tightening of equipment earthing.
8. Any other work as per site requirement of as per direction of site incharge. | 20 | Job | 3,500 ₹70,000 | 2,000 ₹40,000 Lowest |
| 5.00 | Following work to be carried out for preventive maintenance of 33kV Bays (CB, CT, PT, LA & Isolator) on quarterly basis (9 Bays x 4 times= 36)
1. Tightening of clamps & connectors and replacement of the same if found damaged/defective.
2. Cleaning of Porcelain insulator and checking of damage.
3. Replacement of rusted nuts/bolts of CT, PT, LA, CVT etc..
4. Top up of oil after checking oil level in CT/PT/CVT.
5. checking of healthiness of surge arrestors.
6. Apply CRC in junction boxes of CT, CVT etc.
7. Checking & tightening of equipment earthing.
8. Any other work as per site requirement of as per direction of site incharge. | 36 | Nos. | 2,500 ₹90,000 | 1,000 ₹36,000 Lowest |
| 6.00 | Following work to be carried out for prevenetive maintenance for 220kV Isolators (24 isolators x 2 times = 48)1. Alignment of Isolators & earth links.
2. Apply CRC in all isolator junction boxes.
3. Cleaning of Porcelain insulator and checking of damage.
4. Replacement of rusted nuts/bolts of isolator..
5. Tightening of male & female contacts and replace if found damage/defective.
6. Apply petrolleum jelly between male and female contacts of isolators.
7. Tightening of earthling & isolator.jaw.
8. Lubrication of all moving parts.
9. Testing of drive motor in isolator box.
10. Any other work as per site requirement of as per direction of site incharge. | 48 | No. | 2,500 ₹1,20,000 | 2,000 ₹96,000 Lowest |
| 7.00 | Following work to be carried out for prevenetive maintenance for 132kV Isolators 15 isolators x 2 times = 30)1. Alignment of Isolators & earth links.
2. Apply CRC in all isolator junction boxes.
3. Cleaning of Porcelain insulator and checking of damage.
4. Replacement of rusted nuts/bolts of isolator..
5. Tightening of male & female contacts and replace if found damage/defective.
6. Apply petrolleum jelly between male and female contacts of isolators.
7. Tightening of earthling & isolator.jaw.
8. Lubrication of all moving parts.
9. Testing of drive motor in isolator box.
10. Any other work as per site requirement of as per direction of site incharge. | 30 | Job | 1,500 ₹45,000 | 1,000 ₹30,000 Lowest |
| 8.00 | Following work to be carried out for prevenetive maintenance for 33kV Isolators (27 isolators x 2 times = 54)
1. Alignment of Isolators & earth links.
2. Apply CRC in all isolator junction boxes.
3. Cleaning of Porcelain insulator and checking of damage.
4. Replacement of rusted nuts/bolts of isolator..
5. Tightening of male & female contacts and replace if found damage/defective.
6. Apply petrolleum jelly between male and female contacts of isolators.
7. Tightening of earthling & isolator.jaw.
8. Lubrication of all moving parts.
9. Testing of drive motor in isolator box.
10. Any other work as per site requirement of as per direction of site incharge. | 54 | Job | 2,000 ₹1,08,000 | 1,000 ₹54,000 Lowest |
| 9.00 | Providing 1 No Of skilled labor on daily basis (24x7 duty) for miscellaneous works of switchyard, control room & general maintenance of substation @17500/month. | 365 | Days | 700 ₹2,55,500 | 600 ₹2,19,000 Lowest |
| 10.00 | 132KV SUBSTATION BHAGWANPUR
Following work to be carried out for preventive maintenance on quarterly basis of 3 No. of 132/33kV 40 MVA T/F
1. Checking of oil level in main & OLTC conservator tank and bushings.
2. Attending minor oil leakage/seepage from main body/conservator tank/radiator of transformer by tightening.
3. Tightening of all bushing clamps & repacement of damaged/defected clamps and connectors.
4. Rectification of electrical fault of auto/manual operation of cooling fans by replacement of electrical equipment like contactor, MCB, relay etc.
5. Tightening of neutral and main body earthing.
6. Cleaning and washing of transformer main tank/radiator etc.
7. Tightening of all electrical connections in transformer marshalling box & applying CRC.
8. Testing of WTI, OTI, buccholz relay and PRV.
9. Any other work as per site requirement of as per direction of site incharge. | 10 | Job | 3,500 ₹35,000 Lowest | 6,500 ₹65,000 |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
15 Apr 2024, 3:00 pmClosed
Chief Engineer O and M Garhwal Zone Roorkee
Chief Engineer O and M Garhwal Zone PTCUL 26 Civil lines Roorke
Annual Maintenance Contract of 220KV 132KV and 33 KV bays and substation equipments along with 220KV 132KV Lines under 220KV OandM Division Piran Kaliyar
2024_PTCUX_71116_1
CE/GZR-39/2023-24
Open Tender
Electrical Works
Item Wise
365 days
Piran Kaliyar Roorkee
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,360
Yes
SE Oand M Transmission Circle Roorkee
₹1.3 L
Yes
27 Jun 2026
7 Mar 2024
16 Apr 2024
7 Mar 2024
15 Apr 2024
7 Mar 2024
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .