Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC | ₹4.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹5.0 L+₹13,882.31 (2.87%)Rejected-Finance | ₹5.0 L+₹13,882.31 (2.87%) | L2 | Rejected-Finance L2 |
| 3 | L3₹5.0 L+₹18,862.52 (3.90%)Rejected-Finance | ₹5.0 L+₹18,862.52 (3.90%) | L3 | Rejected-Finance L3 |
| 4 | L4₹5.3 L+₹48,930.48 (10.1%)Rejected-Finance R 40 VIKAS MARG SAKAR PUR DELHI 92 | ₹5.3 L+₹48,930.48 (10.1%) | L4 | Rejected-Finance L4 |
Tender Value
₹6.2 L
EMD Value
₹12,600
Closing Date
17 Apr 2026, 10:45 amClosed
Ex. Engineer(Elect.)/CNZ
C-Block, Defence Colony, New Delhi 110024
Provision of lighting arrangement ( 5 m Octagonal Poles with LED Fitting) 10 block Park in Lodhi Colony, Andrews Ganj, Ward No. 145, New Delhi- 110049.
2026_MCD_274831_1
EE(Elect.)/CNZ/2026-27/01-02
Open Tender
Electrical Works
Percentage
60 days
Ward no 145
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹12,600
14 Jul 2026
16 Apr 2026
17 Apr 2026
16 Apr 2026
17 Apr 2026
16 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm | 32 | PM | 77 | ₹2,464 |
| 2 | Supplying & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required .(a) 3 x 1.5 sq. mm | 168 | Pm | 104 | ₹17,472 |
| 3 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. (but without charcoal/ coke and salt ) as required. | 4 | nos. | - | - |
| 4 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. | 8 | PM | 287 | ₹2,296 |
| 5 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. | 252 | PM | 70 | ₹17,640 |
| 6 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 45 watt | 28 | Each | 1,966 | ₹55,048 |
| 7 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. Up to 35 sqmm | - | PM | 47 | - |
| 8 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sqmm | 14 | PM | 36 | ₹504 |
| 9 | Supplying and fixing of light class GI pipe of 50 mm dia (nominal) 3 meters length along the pole for protection of under ground cable as required. | 2 | nos. | - | - |
| 10 | S/L of following size DWC HDPE Pipe ISI marked along with all accessories like socket ,bend ,couplers etc.conforming to IS 14930 ,part II complete with fitting and cutting ,jointing etc .direct in ground (75 cm below ground level )including excavation and refilling the trench but excluding sand cushioning and protective covering etc, complete as required (a)63mm dia (OD-63mm ID -51mm nominal ). | - | PM | 289 | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 12.40 MB
Tendernotice_2.pdf
PDF • 5.22 MB
Tendernotice_3.pdf
PDF • 0.67 MB
BOQ_321019.xls
BOQ • 1.62 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .