Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹73.8 L+₹1.8 L (2.55%)Qualified Make: EICHER ENGINES JAYCEE
Model: EICHER ENGINES(TAFE) JPS/3152A-I INDIA | Make: EICHER ENGINES JAYCEE
Model: EICHER ENGINES(TAFE) JPS/3152A-I | L2 | Qualified | |
| 2 | Qualified Make: PERFECT DG SETS
Model: PERFECT (PECH - 15) 140 NAGINDAS MASTER ROAD MUMBAI MAHARASHTRA 400001 | MUMBAI | MAHARASHTRA | 400001 | Make: PERFECT DG SETS
Model: PERFECT (PECH - 15) | - | Qualified | |
| 3 | L1₹72.0 LDisqualified Make: Koel Green Electro
Model: KOEL GREEN KG1-15AS1 WITH PART NO. 318129-3212-B | Make: Koel Green Electro
Model: KOEL GREEN KG1-15AS1 WITH PART NO. 318129-3212-B | L1 | Disqualified | |
| 4 | Disqualified Make: Prasha Leypower
Model: Ashok Leyland & LP15D1 IMT GURUGRAM HARYANA 122050 | GURGAON | HARYANA | 122050 | Make: Prasha Leypower
Model: Ashok Leyland & LP15D1 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
24 May 2018, 4:00 pmClosed
diesel generators- DG Sets Average Turn Over of Last 3 Years 10000 Lakh (s) Experience with Gov. Required 2 Year (s) Diesel Generators- DG Sets ( 18 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 15 15 No of Phase - threephase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine true - BIS license No
if applicable - - Type of Engine cooling Air Cooled aircooled Type of governer Mechanical mechanical Class of governer A1 a1 Number of cylinders (nos) 2 - No of Strokes (nos) 4 - 1/5 Rated RPM of Engine (RPM) - 1500 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 15 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 89.6 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel AMF amf IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 2 1.6
1.8
2
1.2 Thickness of Foam 25 - Density of Foam for sound insulation 30 - Noise level at 1 meter (dB) 72.5 - BATTERY Battery Type & Specification Normal lead acid to IS: 7372 for motor vehicles - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - 2/5 Test Report number and date(Engine) - - Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning With Installation withinstallation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Jayant Kumar Tyagi 246429
8th Bn ITBP Gauchar 4 15 2 Sher Singh 248146
1st bn suneel joshimath
chamoli (uttrakhand) 1 15 3 Chhering Tashi Bodh 175101
2nd BN I.T.B.POLICE KULLU 6 15 4 Harish Chandra Upreti 248146
23rd BN ITBP Camp Seemadwar 4 15 5 Sukhraj Singh Sidhu 171001
43rd BN ITBP Shalabag
sarahan 1 15 3/5 6 Anil Kumar Jha 134111
50th BN itbp Ramgarh 2 15 EMD Required No ePBG Advisory Bank State Bank of India ePBG Percentage(%) 5.00 Duration of ePBG required (Months). 26
85674
GEM/2018/B/12223
diesel generators- DG Sets
15 days
Uttarakhand; Chamoli, Uttarakhand; Dehradun, Uttarakhand; Kullu, Himachal Pradesh; Shimla
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| diesel generators- DG Sets Average Turn Over of Last 3 Years 10000 Lakh (s) Experience with Gov. Required 2 Year (s) Diesel Generators- DG Sets ( 18 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 15 15 No of Phase - threephase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine true - BIS license No | - | - | - |
| if applicable - - Type of Engine cooling Air Cooled aircooled Type of governer Mechanical mechanical Class of governer A1 a1 Number of cylinders (nos) 2 - No of Strokes (nos) 4 - 1/5 Rated RPM of Engine (RPM) - 1500 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 15 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 89.6 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel AMF amf IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 2 1.6 | - | - | - |
| 1.8 | - | - | - |
| 2 | - | - | - |
| 1.2 Thickness of Foam 25 - Density of Foam for sound insulation 30 - Noise level at 1 meter (dB) 72.5 - BATTERY Battery Type & Specification Normal lead acid to IS: 7372 for motor vehicles - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - 2/5 Test Report number and date(Engine) - - Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning With Installation withinstallation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Jayant Kumar Tyagi 246429 | - | - | - |
| 8th Bn ITBP Gauchar 4 15 2 Sher Singh 248146 | - | - | - |
| 1st bn suneel joshimath | - | - | - |
| chamoli (uttrakhand) 1 15 3 Chhering Tashi Bodh 175101 | - | - | - |
| 2nd BN I.T.B.POLICE KULLU 6 15 4 Harish Chandra Upreti 248146 | - | - | - |
| 23rd BN ITBP Camp Seemadwar 4 15 5 Sukhraj Singh Sidhu 171001 | - | - | - |
| 43rd BN ITBP Shalabag | - | - | - |
| sarahan 1 15 3/5 6 Anil Kumar Jha 134111 | - | - | - |
| 50th BN itbp Ramgarh 2 15 EMD Required No ePBG Advisory Bank State Bank of India ePBG Percentage(%) 5.00 Duration of ePBG required (Months). 26 | - | - | - |
Exempted
24 May 2018
14 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_85674.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .