Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹22.7 L+₹3.2 L (16.2%)Rejected-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹25.1 L+₹5.5 L (28.5%)Rejected-AOC 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹27.6 L+₹8.1 L (41.5%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹28.3 L+₹8.8 L (45.3%)Rejected-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
13 Sept 2021, 6:00 pmClosed
GE I CG PORBANDAR
MILTARY ENGINEERING SERVICES, DHQ-01 GE I CG PORBANDAR OPP BIRLA FACTORY PORBANDAR
REPAIR/ MAINTANANCE OF INTERNAL ELECTRIFICATION, MAINTAINENCE OF ACS,GEYSER WATER COOLER ETC AT CG DHQ NO1, CG JETTY PORBANDAR AND CGAE PORBANDAR UNDER GE I CG PORBANDAR
2021_MES_469776_1
8639
Open Tender
Civil Works
Item Rate
180 days
DHQ-01 PORBANDAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE I CG PORBANDAR
₹40,000
Yes
28 Oct 2021
21 Aug 2021
14 Sept 2021
21 Aug 2021
13 Sept 2021
4 Sept 2021
Amount
SCHEDULE 'A'
Internal Electrification Taking down carefully burnt out aluminium/copper point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, flourescent tube light fittings etc to be measured and paid for seprately) removing materials to store for schedule of credit and making good to the disturbed surfaces of walls ceilings and floors etc complete all as spd and directed.
Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces inclduing painting
Modular Point wiring M & L for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable of size 1.5 Sqmm, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors in exsisting conduit/ Provision of PVC cassing capping as per site requirment conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm size PVC medium grade surface/recessed cassing capping, modular cover-plates and frame complete all as specified in IS: 732- 1989 and directed. Make Anchor/Polycab/RR cables NOTE: Circuit wire from DB to switch boards hall be included in quoted rate. Note (i) Exsisting Modular sheet metal box should not be removed (ii) Mounting plate and cover plate of exsistng size is to be replace and rate are deemed to be inlcuded in quoted rate. (iii) PVC cassing capping measured and paid under relevent Item.(a) One light/ Bulb Holder /fan/exhaust point / bell point controlled by one, one way switch
(d) One light point controlled by 2, Two way switch
(c) One 5 pin socket outlet 5/6 amps on the same board.
(d) One 5 pin socket oulet 5/6 amps on independent board..
M & L for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694- 1990, having multi drawn thin strands of electrolytic copper conductors, conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm size PVC medium grade surface/recessed cassing capping conforming to IS: 537 (Part 3)- 1983, colour-coded as specified in IS: 11353- 1985, and including modular cover plates complete all as specified in IS: 732- 1989 and directed.Make Anchor/Polycab/RR cables Note: (i) Exsisting Modular sheet metal box should not be removed (ii) Mounting plate and cover plate of exsistng size is to be replace and rate are deemed to be inlcuded in quoted rate. (iii) PVC cassing capping measured and paid under relevent Item. One 16 A socket outlet,independent, with cables 2.5 mm² size
S & F in replacement of modular type 6 A one-way SP switch, conforming to IS: 3854-1997 with finger proof terminalcomplete as specified and directed. Make Anchor/ Havells/Legrand
S & F replacement of modular type 16 A one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal complete as specified and directed . Make Anchor/ Havells/Legrand
S & F replacement of modular type 2/3 pin combined shuttered type 6 A socket conforming to IS: 1293- 2005 complete as specified and directed. Make Anchor/ Havells/Legrand
S & F replacement of modular type 2/3 pin combined shuttered type 6/16 A socket conforming to IS: 1293- 2005 complete as specified and directed. Make Anchor/ Havells/Legrend
S & F replacement of modular type 6 A bell-push conforming to IS: 8884- 1978 with finger proof terminal complete all as specified and directed.
S & F replacement of Bell multi music type 230 Volt complete as specified and directed. Make Anchor/ Havells/Legrend
S & F in replacement of modular type 120 W step fan regulator of 2 module size, conforming to IS: 11037-1984 complete as specified and directed.
S & F in replacement of 6 A, 250 V high quality robust surface/flush type polycarbonate/PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5 mm complete all as specified and directed.
S & F in replacement of Modular switch 2 way 6A, 1 module complete all as specified and as drirected
Supply and fix in replacement of Socket outlet 3 pin, 16 Amp, flush type complete all as specified and directed. Make Havells /Anchor/Legrend
Supply and fix in replacement of switch piano flush button 230 V, 16Amps, Single pole,one way ISI marked complete all as specified and directed. Make Havells /Anchor/Legrend
M & L for submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm size in exsisting conduits / PVC Cassing capping surface/recessed conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor with painting, all complete as specified and directed. Make: RR Kabel, Polycab, Havells, Finolex (HR-FR flexible cable) & Precision, Prince, Supreme NOTE: 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of PVC Cassing capping shall be measured as one length. 2 x 6.0 Sqmm + 1 x 6.0 Sqmm earth wire
M & L for submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm size in exsisting conduits / PVC Cassing capping surface/recessed conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor with painting, all complete as specified and directed. Make: RR Kabel, Polycab, Havells, Finolex (HR-FR flexible cable) & Precision, Prince, Supreme NOTE: 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of PVC Cassing capping shall be measured as one length. 2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire
Supply and fixing in replacement of casing capping of 25x 16 mm size complete all as specified and as directed Make Pressfit or Equivalent
Supply and fixing in replacement of casing capping of 32x16 mm size complete all as specified and as directed Make Pressfit or Equivalent
Supply and fixing in replacement of PVC Modular surface box of following size complete all as specified and as directed Make Anchor or Equivlent 1 or 2 Module of size 85x 85 mm
3 Module of size 85x 115 mm
4 Module of size 85x 145 MM
6 Module of size 132x 135 mm
Supply and fixing in replacment of Modular cover plate with frame of following size complete all as specified and as directed Make Anchor or Equivlent 1 or 2 Module
3 Module of size 85x 115 mm
4 Module of size 85x 145 MM
6 Module of size 132x 135 mm
Split AC (Non Inverter AC) M & Lfor servicing and testing of Split type air conditioners of 1.5/2 ton capacity of any make inverter / non inverter complete for minimum two times during the contract period of each unit by cleaning cooling coil, condenser fins, blowing of dust from machines & air filters, checking and de-carbonizing , oiling, compressor greasing of blower motor, checking and removing any vibration, remvoing and cleaning the air filter pad testing after fixing at site all as directed.
M&L for detecting the cause of leakage in any type/capacity of 1.5/2 ton inverter / non inverter AC and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity including testing for smooth functioning complete all as spd and as directed by Engr-In Charge Notes :- (i) Dismantling of unserviceable compressor, cost of refrigarent gas and re-installation of serviceable compressor after repairing are deeemed to be included in the quoted rates .
Split type ac 1.5 /2Ton M & L for repairing of PCB suitable for split type AC 1.5 TR type indoor unit complete all as specified and as directed.
All as per Item No 23 above but for split type AC 2 TR for indoor unit
M & l for replacement of indoor cooling coil of split type AC 1.5 TR unit complete all as specified and as directed.
All as per Item No 25 above but for split type AC 2 TR
M & Lfor replacement of Blower motor,single phase,280-380Volt ,50Hz 3 speed for 1.5 Ton indoor unit complete all as spd and directed.
All as per Item No 27 above but for split type AC 2 TR
M & L in replacement of remote suitable for 1.5/2 Ton all as spd and directed.
M & L for replacement of Drain out PVC Pipe of 11/16 inch dia/17.79 mm innerdia for 1.5 Ton/2 ton ac complete all as spd and directed.
M & L for replacement of swing motor 230Volt for 1.5/2 Ton ac complete all as spd and directed.
M &L for replacement of compresser of outdoor unit of split type AC 1.5 TR complete all as specified and as directed.
All as per Item No 32 above but for split type AC 2 TR
M & L for replacement of out door copper condencer unit of size 20x 30inch size cu tubing size 6 mm dia for outdoor Unit of split type AC 1.5 TR complete all as specified and as directed.
All as per Item No 34 above but for split type AC 2 TR
M & L for replacement of fan motor for ac 230Volt 1180 Rpm for outdoor unit split type AC 1.5 TR complete all as specified and as directed.
All as per Item No 36 above but for split type AC 2 TR
M & L for replacement of running capacitor for motor of capacity 2/4/6 mfd 230 volt suitable for 1.5 Ton ac outdoor unit complete all as specified and as directed.
M & L for replacement of compresser running capacitor of 50 mfd 230 volt suitable for 1.5 Ton ac outdoor unit complete all as specified and as directed.
M & L for replacement of compresser running capacitor of 55 mfd 230 volt suitable for 2Ton ac outdoor unit complete all as specified and as directed.
M & L for replacement of compresser starting capacitor of 45 mfd 230 volt suitable for 1.5 Ton ac outdoor unit complete all as specified and as directed.
M & L for replacement of fan motor blade suitable for motor of 1.5/2 Ton ac outdoor unit complete all as specified and as directed.
M & L for replacement of suction copper tubing of size 5/16'' dia meter with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge.
M & L for replacment of discharge copper tubing of size exsisitng size mm bore including brazing etc and with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge of
M & L for with rubberised insulation cover inclduing tape suitable supply pipes for air-conditioners complete all specified by Engineer -in-Charge
Supply and fixing cable PVC insualted multistranded cu concutor pvc cable of 3 core 3 Sqmm size complete all as specified and directed by Engineer -in-charge
S & Fin replacment of outdoor unit stand of metal inclduing fixing accessories such as nut bolt washers and fastner for 1.5/2 Ton outdoor unit complete all as specified and as directed
S & Fin replacment of indoor unit bracket of metal inclduing fixing accessories such as nut bolt washers and fastner for 1.5/2 Ton outdoor unit complete all as specified and as directed
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed Make ABB/Havells/legrend
Inverter Split ac 1.5 /2ton M & L for repairing of PCB suitable for Inverter type split type AC 1.5 TR type indoor unit complete all as specified and as directed.
All as per Item No 51 above but for split type AC 2 TR for indoor unit
M & Lfor replacement of Blower motor,single phase,230V,ac for 1.5 Ton indoor unit of Inverter AC complete all as spd and directed.
All as per Item No 53 above but for split type AC 2 TR for indoor unit
M & l for replacement of indoor condencer copper coil of inverter split type AC 1.5 TR complete all as specified and as directed.
All as per Item No 55 above but for split type AC 2 TR for indoor unit
M & l for replacement of oudoor condencer unit of copper with 2 run of copper pipe of out door unit of inverter split type AC 1.5 TR complete all as specified and as directed.
All as per Item No 57 above but for split type AC 2 TR for outdoor unit
M &L for replacement of compresser of outdoor unit of split type AC 1.5 TR inverter type complete all as specified and as directed.
All as per Item No 59 above but for split type AC 2 TR for indoor unit
M & L for replacement of swing motor 230 Volt for 1.5Ton indoor unit inverter type ac complete all as spd and directed.
All as per Item No 61 above but for split type AC 2 TR for indoor unit
Taking down of split type AC1.5Ton Inverter type from site for replacement of outdoor unit and re installing split type AC at site and including refixing of outdoor unit on wall and outdoor unit an wall mounted including bracket of MS and replacement of refrigerant tubing as per site std requirement upto 6 RM,any insulated complete all as spd and as directed Note- Gas charging if required deemed to be included in unit rate. Make Voltas/Carrier/Hitachi
Taking down of split type AC1.5Ton Inverter type from site for replacement of indoor unit and re installing split type AC at site and including refixing of indoor unit on wall and outdoor unit an wall mounted including bracket of MS and replacement of refrigerant tubing as per site std requirement upto 6 RM,any insulated complete all as spd and as directed Note- Gas charging if required deemed to be included in unit rate. Make Voltas/Carrier/Hitachi
Water Cooler M & L for servicing and maintenance of water cooler,replacement of wornout parts,cleaning of inner tank complete all as specified and as directed
Supply and fix hermetically sealed compressor of water cooler of capacity 40 ltr/hr suitable for R134a gas, single phase alongwith capacitor and relay, including gas charging in the system and testing of water cooler complete all as spd and as directed by Engr-In Charge. Make : Copeland/Tecumseh. Note : Cost of cutting of existing worn out compressor will be deemed to be included in unit rate.
Taking out burnt unserviceable condenser fan motor,and replacement with new electric motor,single phase 230V of water cooler 40ltrs/hrs with condenser fan blade complete all as spd and as directed
Supply and fix in replacement of following items of water cooler Thermostat for water cooler capacity 40/80 ltr/hrs. Make:Renetor/shriram/Godraj/Danfoss
Push type Bib tap Cast copper alloy 15 mm Push type chromium plated.
PVC Connection with brass unions at both ends with brass nuts, suitable for fixing to 15 mm dia GI Pipe.
Repairs to Refrigerators M & Lfor charging of refrigerant with exsisitng refrigerent in refrgerator of 165 to 315 Ltr capacity, deepfreezer and water Cooler of 40/80 Ltr and double door refergerator of 984 Ltr capacity with appropriate quantity including testing for smooth functioning complete all as spd and as directed.
S& F in replacement of overload relay suitable for following capacity refrigerator including necessary capillary complete all as spd and as directed Make -As per existing Refrigerator capacity 300 Ltr
Refrigerator capacity 315 Ltr
Refrigerator capacity 180 Ltr
S& F in replacement of condensor fan motor suitable for following capacity refrigerator including necessary capillary complete all as spd and as directed Make -As per existing Refrigerator capacity 300 /315 Ltr
Refrigerator capacity 180 Ltr
S& F in replacement of compressor Run Capacitor suitable for following capacity refrigerator including necessary capillary complete all as spd and as directed Make -As per existing Refrigerator capacity 300 /315 Ltr
Refrigerator capacity 180 Ltr
S& F in replacement of Temp control thermostate suitable for following capacity refrigerator including necessary capillary complete all as spd and as directed Make -As per existing Refrigerator capacity 300/315 Ltr
Refrigerator capacity 180 Ltr
Ceiling/Exhaust Fan Taking down of followin items for servicing, cleaning all the dust partical and oiling and greasing the bearing and cheking the electrical connection, including painting and refixing of ceiling fan/exhaust fan and wall mounted fan in situ complete aall as spd and directed. Note: (i) Spare parts will be measured and paid separatly . (ii) Rewinding/repair of fan motor will be measured and paid seprately. Ceiling Fan 1200 mm sweep
Exhaust Fan 240/300 mm
Exhaust Fan 450 mm
Wall mounted fan 300 mm
M & L for cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling and other repairing work complete all as spd and directed by Engineer-in-Charge.Note Taking down and refixing charges will be paid under relvent items Ceiling Fan 1200 mm sweep
Exhaust Fan 240 mm
Exhaust Fan 450 mm
Wall mounted fan 450 mm
Supply only spare parts of Fan/Exhaust fan of following rating all as spd and directed Capacitor 2.5 MFD
Capacitor 3.15 Mfd
Ball Bearing No 6201
Ball Bearing No 6202
Mild steel Down Rod 600 mm Long with Clamp nut bolts & split pin as par sample
Mild steel Down Rod with Clamp nut bolts& split pin for 900 mm Long as par sample
Ceiling Fan Blade suitable for 1200 mm sweep as per sample.
Ceiling fan canopy suitable for 1200 mm sweep
Storage type water heater Dismantling electric/water connection and taking down of storage type water heater,servicing,cleaning of inner tank etc.at site.and replacement of burnout parts etc. and refixing in situ all spd and directed. Note- wornout parts shall be measured as seperatly.
Supply & fix in replacement of Heating element 1.5/2 KW Tringular/ circular type with rubber gasket complete all as specified and as directed
Supply & fix in replacement Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked complete all as specified and as directed
Supply & fix in replacement 3 core 1.5 sqmm PVC insulated cable 1.5 m long with 3 pin 15 Amp plug top complete all as specified and as directed
S&F in replacment of LED luminaire, Aluminium extruded housing, 20W,lumen output not less than 2000 lm, 220-240V, 50Hz, PF>0.9,CCT 4000K,including connecting cable 2 core 0.5 sqmm from ceiling rose to terminal block complete all as specified and directed. Make: BN 021 LED 40S-6500PSUL120GR OF Philips (smart brite / Wipro/GE)
S&F Recessed mounting LED downlighter with high efficiency, housing made of extruded aluminium, 240V, 50Hz,24 Watt, CCT 5700K, round in shape,complete all as specified and directed by Engineer-in-Charge. Make: Cat no: Wipro LD06-301-XXX-57-XX*** Or Equivalent from Philips / GE Lighting. Note:- Cost of replacing light fitting in existing cut out of false ceiling board and making good disturbed surfaces as per existing deemed to be included in the quoted unit rate.
S&F Recessed mounting LED downlighter with high efficiency, housing made of extruded aluminium, 240V, 50Hz,18 Watt, CCT 5700K, square /round in shape,complete all as specified and directed by Engineer-in-Charge. Make: Cat no: Wipro LD06-221-XXX-57-XX*** Or Equivalent from Philips / GE Lighting. Note:- Cost of replacing light fitting in existing cut out of false ceiling board and making good disturbed surfaces as per existing deemed to be included in the quoted unit rate.
OM ENGINEERING
Vijay Construction Co
Parth Infrastructure Pvt. Ltd.
K K Construction Co
Nitesh Enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .