23 Mar 2026, 4:00 pmClosed
Assistant Engineer
O/o The Assistant Engineer Kalyani Electrical Sub-Division, P.W.D. P.O.-Kalyani, Dist- Nadia
Annual Maintenance of Electrical Installation of Haringhata Dairy, Nadia for the year 2025-2026 Repairing of E.I. Work and different types of motor at dairy factory.
2026_WBPWD_1021871_1
WBPWD/AE/e-NIT- 25/KLY of 2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Haringhata Diary
Please refer Tender documents.
6 documents required · 6 mandatory
₹6,661
11 May 2026
13 Mar 2026
25 Mar 2026
13 Mar 2026
23 Mar 2026
16 Mar 2026
S & F of Motor protection Relay M.P.R-300 O/L Range (32-88)Amps Cat No MPR-305BF320 240 V-A-C Make L&T
S & F of Phase failure relay (Auto reset, 60 Volt unbalance fixed 1 co contact DIN Rail Mounted type U S P D1. Make-Minilec
Dismantling the above motor after disconnection of electrical connection.
Opening the 2 no. motor, checking and testing part by part and dismantling the burnt copper wire cleaning the motor.
Rewinding of 10/15 hp duel speed motor with duble colated super enamald cupper weir including insulating nomex paper Dr, Bake varnish & heat baking complete.
Rewinding of 2/1.5 hp duel speed motor with duble colated super enamald cupper weir including insulating nomex paper Dr, Bake varnish & heat baking complete.
Supply & fitting 2 no. bearing no. 6309 SKF for above duel speed motor.
Supply & fitting 2 no. bearing for above duel speed motor 2/1.5 hp motot set.
Repairing of break assembly with supply & pesting new shoos pade.
Dismantalling pump part by part and washing Clening & refitting the same.
Hand painting, with quality paint 2cots bouth motor.
Carrying charges above 2no. Motor from side to workshop & return workshop to side after complete the job.
Both the motor refitting at same place & same electrical connection.
Supply of 1.1 KV Gr. 2 Core 10 sq. mm XLPE Insulated & Sheathed Armored Aluminum Conductor Cable [Make - Finolex / Polycab / Havells / Universal].
Laying of one no. 2 core 10 sq. mm cable in underground trench of 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) nos. bricks per meter including filling the space between the bricks and cable and also the trench with shifted soil, leveling up and restoring surface duly rammed [1(a)/F-2]
Road boring (Micro Tunneling) for 50 mm dia pipes / as per requirement / as per instruction of EIC with necessary tools & tackles complete including GI pipe pushing. (NS)
S & F of 50 mm dia medium gauge GI pipe (ISI - Medium) protection with necessary fittings and jointing materials as required. [11(d)(ii)/F-6]
Emergency Checking, testing & rectification of 230 Volt LT line such as checking of - main switch, tightening nut bolt, TPNBDB, SPNBDB, Air Compressor Automatic control Panel Board etc as per direction of EIC by one -skilled, two- semi skilled, three-unskilled labour and co's own tools and tackles as per direction of EIC. [NS]
Distribution wiring in 3 x 1.5 sq. mm single core stranded 'FR' PVC insulated & unsheathed copper wire (Make - Finolex / Havells / RR Kabel) in 20 mm size MMS PVC rigid conduit 'FR' (Precision make) to light/fan/call bell ..and incl. 175 mm x 100 mm x 65mm inspection box, making earthing attachment, painting the MS box and mending well the damages to the original finish. Average run - 9 Mtr. [2(d)/E-14]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
3 x 1.5 sq. mm E-14/1-i
2 x 2.5 sq. mm + 1 x 1.5 sq. mm. E-14/1-ii
Supply & Fixing 240 V, 3 nos. 6 A, & 1 no. 20 A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch,... incl. S & F Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board ... as required. E-7/ 25
Checking, testing of 11 KV overhead HT line, checking testing like-checked insulator, tightening nut bolt of isolator, trimming the tree branches falling over HT line,& four 11kv conductor joint, labour- skilled two, semi-skilled two, unskilled two per day [NS]
Supplying & Fixing universal parallel-groove (1 Bolt type) clamp for AAC/ACSR (Aliened type). [(G)-4./H-5]
Supply & fixing of 11 kv post top insulator 400 amp capacity after dismantling damaged one.
Supplying & Erection of 50x50x6x600 mm long Galv. angle iron cross-arm for carrying insulators incl. painting.[7(C-4)/H-3]
Supplying & Erection of 75x88 mm porcelain shackle insulator complete with 190x30x5 mm Galv. (Hot Dip) strips with 15.88 mm dia Galv. bolts, nuts, etc. for conductor upto 7/3.10 mm, 32 sqmm of AAC/equivalent size of ACSR.[7(D-1)/H-3]
Supply & fixing of PLUTO PRO street LED light fitting. [ make Cromptom](Cat no - CFS-501-150-57-60D-SL-GL-NGG )[NS]
Supply & fixing of box type 4 ft. long, IP 65 protected 240V, 40Watt covered luminaire with LED tube light fitting complete with all accessories [Make -Havells Magnum Retro 18w x 2T/Wipro/Philips/EIC approved]. [NS]
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.41 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.50 MB
2911.pdf
Tender Documents • 0.50 MB
BOQ_2511580.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .