Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | ₹18.6 L Quoted ₹19.0 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹23.2 L+₹4.2 L (22.2%)Rejected-AOC | ₹23.2 L+₹4.2 L (22.2%) | L2 | Rejected-AOC not lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
9 Nov 2020, 6:00 pmClosed
GE (AF) Jodhpur
GE (AF) Jodhpur
CERTAIN REWIRING AND REPLACEMENT OF US FITTING AND MAINT OF CEILING / PEDESTAL FAN / WALL MOUNTED / EXHAUST FAN / FLAME PROOF FAN IN TECH AREA AT NORTH SIDE OF RUNWAY AT AF STN JODHPUR
2020_MES_386145_1
8423/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Jodhpur
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹50,000
Yes
1 Dec 2020
13 Oct 2020
10 Nov 2020
13 Oct 2020
9 Nov 2020
27 Oct 2020
Amount
Taking down carefully copper/aluminium point wiring light, fan, socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc. removing materials to store for keeping in safe costudy or for taking credit and making good disturbed surface of walls, floors etc. Complete all as specified and directed by Engineer-in-Charge.
Taking down MCB DB with MCB any type and any capacity Complete all as specified and directed by Engineer-in-Charge.
Taking down Sub main wiring any type any size Complete all as specified and directed by Engineer-in-Charge.
Material & labour for point wiring for One light / Buzzer point controlled by one switch 5 Amp, SP, one way 240 volts, with 1.5 sqmm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable ( using colour code as per IS) 1100 volts grade drawn through and including 20mm dia medium grade rigid PVC conduit (ISI marked) with all accessories including surface / concealed sheet steel terminal / CI box with 3 mm thick hylam / masonite sheet top cover including 1.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly, complete all as specified & directed by Engineer-in-Charge.
All as per item No 4.00 above but one fan point controlled by one switch single pole, one way, 5 Amp, 240 Volts and regulator complete
All as per item No 4.00 above but additional light point on same switch board
All as per item No 4.00 above but one 5 Amp 3 pin multi socket point on independent board
All as per item No 4.00 above but for Call bell controled by one bell push button in indipendent board
All as per item No 4.00 abovebut for light point controled by two switches
Material & labour for point wiring for One 5 pin socket outlet 5/15 Amp multi purpose independent point controlled by 15 Amp, SP, one way 240 volts, with 2.5 Sqmm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable ( using colour code as per IS) 1100 volts grade drawn through and including 20mm dia medium grade rigid PVC conduit (ISI marked) with all accessories including surface / concealed sheet steel terminal / CI box with 3 mm thick hylam / masonite sheet top cover including 1.5 sqmm size FRLS PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly, complete all as specified & directed by Engineer-in-Charge.
Material & labour for point wiring for One 5 pin socket outlet 5/15 Amp multi purpose independent point controlled by 15 Amp, SP, one way 240 volts, with 4Sqmm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable ( using colour code as per IS) 1100 volts grade drawn through and including 20mm dia medium grade rigid PVC conduit (ISI marked) with all accessories including surface / concealed sheet steel terminal / CI box with 3 mm thick hylam / masonite sheet top cover including 2.5 sqmm size FRLS PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly, complete all as specified & directed by Engineer-in-Charge.
Material & labour for point wiring for One light/Buzzer point controlled by one switch 5 Amp, SP, one way 240 volts, with 1.5 sqmm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including surface PVC casing caping (ISI marked) with all accessories including surface/ concealed sheet steel terminal/CI box with 3mm thick hylam/masonite sheet top including 1.5 sqmm size FRLS PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 12.00 above but one fan point controlled by one switch SP one way 5 Amp 240 Volts and regulator.
All as per item No 12.00 above but additional light point on same switch board
All as per item No 12 above but one 5 Amp, 3 Pin, socket point on independent board
All as per item No 12.00 above but for Call bell controled by one bell push button in indipendent board
All as per item No 12.00 above but for light point controled by two switches complete
Material & labour for point wiring for for one 5 pin socket outlet 5/15 Amp multi purpose independent point controlled by 15 Amp switch, single pole, one way, 240 Volts & Socket. SP, one way 240 volts, with 2.5 sqmm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including surface PVC casing caping (ISI marked) with all accessories including surface/ concealed sheet steel terminal/CI box with 3mm thick hylam/masonite sheet top including 1.5 sqmm size FRLS PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
Material & labour for point wiring for one 20 Amp Industrial plug and socket point controlled by 20 Amp MCB, single pole, one way 240 Volts with 2.5 sqmm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including surface PVC casing caping (ISI marked) with all accessories including surface/ concealed sheet steel terminal/CI box with 3mm thick hylam/masonite sheet top including 1.5 sqmm size FRLS PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
Material & labour for point wiring for one light/Buzzer point controlled by one switch 5 Amp, SP, one way 240 volts, with 1.5 sqmm FRLS (nominal area) PVC insulated and unsheathed multistranded copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including surface stove enamelled steel conduit 20mm dia (ISI marked) with all accessories including surface/ concealed sheet steel terminal/CI box with 3mm thick hylam/masonite sheet top including 1.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly Complete all as specified and directed by Engineer-in-Charge.
All as per item No 20.00 above but one fan point controlled by one switch SP one way 5 Amp, 240 Volts and regulator.
Material & labour for point wiring for for one 5 pin socket outlet 5 / 15 Amp multi purpose independent point controlled by 15 Amp switch, single pole, one way, 240 Volts & Socket.240 volts, with 2.5 sqmm FRLS (nominal area) PVC insulated and unsheathed multistranded copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including surface stove enamelled steel conduit 20mm dia (ISI marked) with all accessories including surface/ concealed sheet steel terminal/CI box with 3mm thick hylam/masonite sheet top including 1.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly Complete all as specified and directed by Engineer-in-Charge.
Material & labour for point wiring for one 20 Amp Industrial plug and socket point controlled by 20 Amp MCB, single pole, one way 240 Volts, with 4Sqmm FRLS (nominal area) PVC insulated and unsheathed multistranded copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including surface stove enamelled steel conduit 20mm dia (ISI marked) with all accessories including surface/ concealed sheet steel terminal/CI box with 3mm thick hylam/masonite sheet top including 2.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly Complete all as specified and directed by Engineer-in-Charge. NOTE FOR ITEM 4 TO 23 The unit rate quoted for above items deems to be included for the necessary cutting chases for concealed wiring and removing / refixing of false ceiling and cutting for cancealed boxes and making good distrubed surfaces to match with existing surfaces.
Supply & fixing in repairs switch piano flush type single pole one way, 5 Amp (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs of ding dong bell AC 230 V single pole complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs bell push switch flush type 5 Amp complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs switch socket outlet 2 in 1, 3 pin 6 Amps (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs switch socket outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs MCB SP 240 Volts, 50Hz, 10 kA, conforming to IS 8828 of rating 6 to 32 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs MCB, SPN, 240 Volts, 50Hz, 10 kA conforming to IS 8828 of rating 6 to 32 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs MCB, SPN, 240 Volts, 50Hz, 10kA conforming to IS-8828 of rating 40 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs MCB, SPN, 240 Volts, 50Hz, 10kA conforming to IS-8828 of rating 63 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs MCB TPN, 415 Volts, 50Hz, 10kA conforming to IS-8828 of rating 6 to 32 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs MCB TPN, 415 Volts, 50Hz, 10kA conforming to IS-8828 of rating 40 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs MCB, TPN, 415 Volts, 50Hz, 10kA conforming to IS-8828 of rating 63 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs MCB, TP 415 Volts, 50Hz, 10kA conforming to IS-8828 of rating 40 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs MCB, TP 415 Volts, 50Hz, 10kA conforming to IS-8828 of rating 63 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs MCB, TP 415 Volts, 50Hz, 10kA conforming to IS-8828 of rating 6 to 32 Amps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs ceiling rose surface bakelite 65 mm x 50mm, three terminals ISI (Marked) complete all as specified and directed by Engineer-in-Charge.
Supply & fixing MCB distribution board SPN, 4 ways, 230 Volts, 50 Hz, AC, double door made out of sheet metal phosphatised and painted with epoxy polyster based powder paints with 200 Amps rated bus bar and earth bar, ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fixing MCB distribution board SPN, 8 ways, 230 Volts, 50 Hz, AC, double door made out of sheet metal phosphatised and painted with epoxy polyster based powder paints with 200 Amps rated bus bar and earth bar, ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fixing MCB distribution board SPN, 12 ways, 230 Volts, 50 Hz, AC, double door made out of sheet metal phosphatised and painted with epoxy polyster based powder paints with 200 Amps rated bus bar and earth bar, ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fixing MCB distribution board TPN, 4 Ways, 415 Volts, 50 Hz, AC, double door, vertical type with detachable gland plate, made out of sheet metal phosphatised and painted with epoxy polyster based powder paints with 200 Amps rated bus bar and earth bar, ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fixing MCB distribution board TPN, 6 Ways, 415 Volts, 50 Hz, AC, double door, vertical type with detachable gland plate, made out of sheet metal phosphatised and painted with epoxy polyster based powder paints with 200 Amps rated bus bar and earth bar, ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fixing MCB distribution board TPN, 8 Ways, 415 Volts, 50 Hz, AC, double door, vertical type with detachable gland plate, made out of sheet metal phosphatised and painted with epoxy polyster based powder paints with 200 Amps rated bus bar and earth bar, ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fixing MCB distribution board TPN, 12 Ways, 415 Volts, 50 Hz, AC, double door, vertical type with detachable gland plate, made out of sheet metal phosphatised and painted with epoxy polyster based powder paints with 200 Amps rated bus bar and earth bar, ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs modular plate switches 6 amps single pole one way complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs modular plate socketes outlet 6 amps 5 pin complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs modular plate switches 16 Amps single pole one way complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs modular plate socket 6-16 Amps 3 pin combined shuttered complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs Step fan Speed regulator 5 steps complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs modular white cover platewith frame 12 modular complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs Flush metal boxes 12 modular complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs modular white cover platewith frame 6 modular complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs Flush metal boxes 6 modular complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs modular white cover platewith frame 3 modular complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs Flush metal boxes 3 modular complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs modular white cover platewith frame 8 modular complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs Flush metal boxes 8 modular complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs modular white cover platewith frame 4 modular complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs Flush metal boxes 4modular complete all as specified and directed by Engineer-in-Charge.
Material and labour for submain wiring with two single core PVC insulated multi stranded copper conductor cable FRLS of size 2.5 sqmm 1100 volt grade (ISI marked ) drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories all fixed concealed on wall and surface on ceiling, with one 1.5 Sqmm single core multi stranded copper conductor FRLS as earth continuity to common earth doly as earth wire complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & casing shall be measured and paid as one length.
Material and labour for submain wiring with two single core PVC insulated multi stranded copper conductor cable FRLS of size 4 sqmm 1100 volt grade (ISI marked ) drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories all fixed concealed on wall and surface on ceiling, with one 2.5 Sqmm single core multi stranded copper conductor FRLS as earth continuity to common earth doly as earth wire complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & casing shall be measured and paid as one length.
Material and labour for submain wiring with two single core PVC insulated multi stranded copper conductor cable FRLS of size 6 sqmm 1100 volt grade (ISI marked ) drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories all fixed concealed on wall and surface on ceiling, with one 4 Sqmm single core multi stranded copper conductor FRLS as earth continuity to common earth doly as earth wire complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & casing shall be measured and paid as one length.
Material and labour for submain wiring with two single core PVC insulated multi stranded copper conductor cable FRLS of size 10 sqmm 1100 volt grade (ISI marked ) drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories all fixed concealed on wall and surface on ceiling, with one 6 Sqmm single core multi stranded copper conductor FRLS as earth continuity to common earth doly as earth wire complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & casing shall be measured and paid as one length.
Material and Labour for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for cocealed water tubing or consealed conduit wiring etc.and making good, cutting not not exceeding 10 cm girth complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repairs Steped type electronic fan regulator flash type on the existing phenolic laminated sheet etc suitable for 240 volt complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 415 volt including MCB 20 amps complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repairs 1100 volt grade heavy duty electric power cable PVC insulated Aluminium conductor screwed with inner seathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1metre apart including 4 mm suspension wire with one twin core cable flat circulator 10 sqmm solid conductor complete all as specified and directed by Engineer in Charge.
Taking down carefully and opening, dismantling of ceiling fans 48" sweep cutting and taking out old burnt/damaged winding/material by any means and material and labour for re-winding the same with supper enamelled copper wire of existing/same SWG including all insulating material all as required as per standard practice, varnishing the same and drying, cleaning fan with recommended quality grease/oil, re-assembling and refixing including provision of PVC copper twisted conductor three core of size 0.5 sqmm of required length and testing complete all as specified and directed by Engr-in-charge. Note :- Spare parts shall be measured and paid seperately under respective items of BOQ.
All as per item No 70.00 above but ceiling fan of 1400 mm sweep complete.
All as per item No 70.00 above but exhaust fan of 230 mm sweep complete.
All as per item No 70.00 above but exhaust fan of 300 mm sweep complete.
All as per item No 70.00 above but exhaust fan of 450 mm sweep complete.
All as per item No 70.00 above but wall mounting fan of 400 mm (16") sweep complete.
All as per item No 70.00 above but pedestal fans of 600 mm (24") Sweep complete.
All as per item No 70.00 above but pedestal fans of 400 mm (16") Sweep complete.
All as per item No 70.00 above but industrial air circulator fans of any sizes complete.
Supply only Gun metal bush of ceiling fans any type or any sweep including cutting of grooves for fixing of bearing instead of bush any type/any size complete all as specified and directed by the Engineer in Charge.
Supply only ball bearing suitable for ceiling fan of 1200 mm (48'')/1400 mm(56'') sweep complete all as specified and directed by the Engineer in Charge.
Supply only ball bearing of any sweep sutiable for exhaust fans/pedestal fans of any make & size complete all as specified and directed by the Engineer in Charge.
Supply only capacitor for any type of fan, 230 volts AC including necessary soldering of capacity 2.5 MFD complete all as specified and directed by the Engineer in Charge.
Supply only capacitor for any type of exhaust fan/pedestial fan/air circulator fan 230 volts AC including necessary soldering of capacity 4 MFD for exhaust fans/pedestal fans complete all as specified and directed by the Engineer in Charge.
Supply only oscillation mechanism for table/wall mounting/pedestal fan complete all as specified and directed by the Engineer in Charge.
Supply only plastic canopies of both side for ceiling fan complete all as specified and directed by the Engineer in Charge.
Supply only screw, clamps with nuts & bolts rubber reel with split pin for ceiling fan complete all as specified and directed by the Engineer in Charge.
Supply only rubber reel complete all as specified and directed by the Engineer in Charge.
Supply only shaft any type any size for ceiling fan complete all as specified and directed by the Engineer in Charge.
Supply only Metalic blades for exhaust fan of 380mm sweep (one set of three blades) complete all as specified and directed by the Engineer in Charge.
Supply only Metalic blades for exhaust fan of 450mm sweep (one set of three blades) complete all as specified and directed by the Engineer in Charge.
Supply only metalic blade for wall mounting fan 230/300 mm (one set of three blades) complete all as specified and directed by the Engineer in Charge.
Supply only plastic blade (Set of four blade) for exhaust fan 230/300mm complete all as specified and directed by the Engineer in Charge.
Supply only metallic blade for ceiling fan 1200mm sweep any make including bolt for fixing complete all as specified and directed by the Engineer in Charge.
supply only rubber bush suitable for exhaust fan legs of any size complete all as specified and directed by the Engineer in Charge.
Supply only copper conductor multistranded cable flexible 03 core PVC insulated of size 40/0.076 complete all as specified and directed by the Engineer in Charge.
Supply only fan down rod of metal, size 2 feet long complete all as specified and directed by the Engineer in Charge.
Supply only fan down rod of metal, size 3 feet long complete all as specified and directed by the Engineer in Charge.
Supply only fan down rod of metal, size 6 feet long complete all as specified and directed by the Engineer in Charge.
Supply only fan down rod of metal, size 5 feet long complete all as specified and directed by the Engineer in Charge.
Supply only fan down rod of metal, size 10 feet long complete all as specified and directed by the Engineer in Charge.
Supply only fan down rod of metal, size 12 feet long complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs fan hook of suitable size & shape made of MS channel/FI/Bar fixed to wall/roof/ Pipe complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs Exhaust fan plastic body 150mm sweep complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs Tetra plug and socket DBs 5 modules with & including 63 Amps MCB SPN complete with all connetced wiring complete all as specified and directed by the Engineer in Charge.
Material & labour in repair for earthing complete with galvanised steel earth electrode 60cm x 60cm x 6 mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth strip 25mm x 4 mm, by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil, PCC (1:3:6) Type C1 in earth pit chamber, precast RCC cover 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. GI strip beyond 7.5 Metre shall be measured and paid for separately.
Supply & fixing in repairs 36 watt CFL 4 pin, 230 volt complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs vacuum impregnated copper ballast (VIPT) for CFL 36 watt complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs Exhaust fan AC single phase 230 volt of size 250 mm Sweep noise less Made out of PVC plastic body fixed on plywood with louvere including making a hole in stone wall, finishing with Cement mortar & making good as existing surface complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs Wall mounted decorative Perfect for interior and exterior applications within car parks, walkways, stairwells, corridors, Local authorities and housing associations as well as commercial buildings suitable for 10 watt LED of CG cat part LBHP-10-CDL oe equivalent make given in Appenix "A".
Supply & fixing in repairs 10 watt LED type mirror light fitting to fix on top complete all as specified and directed by the Engineer in Charge.
Supply only plug top 3 pin 15 Amps ISI marked complete all as specified and directed by the Engineer in Charge.
Material & labour for fusible plug suitable for 95 to 100 degree centigrade fix in brass socket for any capacity for geyser 25/50 litre complete all as specified and directed by the Engineer in Charge.
Supply, installing, connecting & testing electronic type tamper proof single phase Range 5 to 30 Amp current rating energy meter in class 1 accuracy as peras per IS : 13779 with LCD type display fixed as in repairs complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs ound surface mounted LED panel. PDC aluminum housing and high translucent frosted plastic diffuser makes it a robust Luminaire. Efficacy 100lm/w complete all as specified and directed by the Engineer in Charge. Make Crompton Greaves cat part No LCDSPLN -R-18-CDL or equivalent make as specified in Appendix 'B' as approved by the GE.
Supply & fixing in repairs Square surface mounted LED panel. PDC aluminum housing and high translucent frosted plastic diffuser makes it a robust Luminaire. Efficacy 100lm/w complete all as specified and directed by the Engineer in Charge. Make Crompton Greaves cat part No LCDSPLN - S -18-CDL or equivalent make as specified in Appendix 'B' as approved by the GE.
Supply & fixing in repairs LED batten Trim line a PC batten, Compact appearance, Efficiancy : 100 lumen/watt complete all as specified and directed by the Engineer in Charge. Make Crompton Greaves cat part No LCTLN-20-CDL or equivalent make as specified in Appendix 'B' as approved by the GE.
Supply & fixing in repairs energy efficient recessed mounted LED luminaire suitable edge lit 2 ft x 2 ft slim panel with super bright LED's & highly efficient light-smoothing optics to deliver superior illumination and energy savings complete all as specified and directed by the Engineer in Charge. Make Crompton Greaves cat part No CCR-127-36-57-SL-NWH (AURA I) or equivalent make as specified in Appendix 'B' as approved by the GE.
Supply & fixing in repairs Building Security Light LED 45 Watt fixture made of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP65 protection,Efficiancy : 110 LM/watt complete all as specified and directed by the Engineer in Charge. All as per Crompton Greaves cat part No . LSTS-45-CDL-M (FREEDOM NEO LED) or equivalent make as specified in Appendix 'B' as approved by the GE.
Supply & fixing in repairs Post Top 10 Watt IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 degree light distribution rated complete all as specified and directed by the Engineer in Charge. All as per Crompton Greaves cat part No . LBLSN-10-CDL or equivalent make as specified in Appendix 'B' as approved by the GE.
Material & labour in replacement of flame proof high bay LED light fitting of capacity 60 watt complete all as specified and directed by the Engineer in Charge. All as per Crompton Greaves cat part no. FWL1315-60-CDL (GLAZE PRO) or equivalent make as specified in Appendix 'B' as approved by the GE.
Supply & fixing in repairs of flame proof 4 feet long LED tube light fitting complete of capacity 2 x 20/16watt including LED lamp complete all as specified and directed by the Engineer in Charge.All as per Crompton Greaves cat part no. EXTN2LT8-16/20 (FIAMMA II) or equivalent make as specified in Appendix 'B' as approved by the GE.
Supply & fixing in repairs of flame proof /weather proof rotary switch on/off type 16 Amp direct entry complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs of flame proof 4 feet long LED tube light fitting complete of capacity 1 x 20/16watt including LED lamp complete all as specified and directed by the Engineer in Charge. All as per Crompton Greaves cat part no. EXTN1LT8-16/20 (FIAMMA II) or equivalent make as specified in Appendix 'B' as approved by the GE.
Material & labour in replacement of flame proof /weather proof MCB DB Double door type made out of LM-6 metal alloy of 8way SPN with 01 no 40 amp SPN on incoming and 06 Nos of SP MCB on outgoing with 04 Nos of 3/4 " entry for cable , with necessary cable glands complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs high efficiency round highbay in PDC housing suitable for industrial application for air craft hanger. The luminaire has efficacy of 110Lm/w reduce quantity /wattage thereby redcing operational cost.Ingress protection of IP66 complete all as specified and directed by the Engineer in Charge.All as per Crompton Greaves cat part no. LHB11-150-CDL/60-M (SURROUND NEO) or equivalent make as specified in Appendix 'B' as approved by the GE.
Supply & fixing in repairs on load changeover switch 63 Amps 415 Volt 4 Pole with sheet metal enclosure, front handle operated complete all as specified by Engineer-in-Charge.
Supply & fixing in repairs metal clad P&S 2P+E Plug and socket 32 Amp IP-44 fitted with a DIN rail for fitted with & including MCB DP 32 Amps , 230 volts complete all as specified by Engineer-in-Charge.
Supply & fixing in repairs MCB TPN 100 Amps C curve Type complete all as specified by Engineer-in-Charge.
Supply & fixing in repairs angle holder / batten holder, insulated body with skirt complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs Tetra plug and socket DBs 5 modules with & including 16 Amps MCB SPN complete with all connetced wiring complete all as specified and directed by the Engineer in Charge.
Supply & fixing in repairs Tetra plug and socket DBs 5 modules with & including 32 Amps MCB SPN complete with all connetced wiring complete all as specified and directed by the Engineer in Charge.
Supply and laying stone aggregate of size 40mm graded layed on ground of two/four/ pole structure complete all as specified and directed.
Supply and laying stone aggregate of size 20mm graded layed on ground of two/four/ pole structure complete all as specified and directed.
Surface cleaning/site clearance n exc 15 cm in depth in Sub stations area, trenches,sub station rooms, two pole/ four pole structure surrounding, LT panel, fencing to make a over all presentable condition all as directed by Eng In charge.
Supply and fixing in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire, including excavation and earth work , refilling etc. compete all as specified and as directed.
Material & labour for Rerouting/Rearranging of existing cable of any type and any size on wall, floor, roof, ground etc a using clips of different sizes and make it presentable condition complete all as specified by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning in replacement of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 10 Sqmm 02 core (heavy duty) 1100 Volts grade with stranded Aluminim conductor complete all as specified by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning in replacement of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 16 Sqmm 02 core (heavy duty) 1100 Volts grade with stranded Aluminim conductor complete all as specified by Engineer-in-Charge.
Material & Labour for disconnecting & dismantling the distribution boards TPN /SPN of any size and removing all the connection, cleaning & removing the carbon from the contacts, cleaning with CTC solution and , replacment of the unserviceable or defective rusted nuts and bolts,old damged door lock etc and also replacement of dammaged accesories reassemble the Distribution board with all the connection properly tight and checked control wiring and make the entire DB serviceable & functional to the entire satisfaction of the Engineer in Charge. Note : MCB/MCCB or other major item required to be replaced, shall be measured and paid separately.
Supply & fixing in repairs DB panel front door made of MS sheet 3.15 mm thick with hinjes and lock system, panel should be well welded, complete all as specified and directed by the Engineer in Charge.
Material and labour disconnecting the existing Panel board , and complete removal of existing treatment from steel surfaces of the LT Panel Board by cleaning/rubbing/scrapping & preparation of surfaces for repainting and including applying two coats of synthetic enamelled paint over a coat of primer, paint shall be of the as per the existing colour of LT Panel boards complete all as specified and directed by the Engineer in Charge Note:- Painting to LT DB Panels Shall be carried out with spray gun equipments.
Material & labour in replacement 40 mm bore GI pipe light grade with all fittings laid in trenches complete all as specified and directed by the Engineer in Charge.
Material & labour in replacement 50 mm bore GI pipe light grade with all fittings laid in trenches complete all as specified and directed by the Engineer in Charge.
Supply only aluminium cable lugs of size 6 sqmm to 10 sqmm complete all as specified and directed by the Engineer in Charge.
Supply only aluminium cable lugs of size 16 sqmm to 50 sq mm complete all as specified and directed by the Engineer in Charge.
Material & labour for PCC type B-1, 1:2:4 (using 20 mm gradded stone aggregate) as in floor, surface dressing, including formwork and dismanting of old unserviceable PCC complete all as specified and directed by the Engineer in Charge.
Achal Sales
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .