Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.8 LAccepted-AOC 234 4 JC BOSE ROAD KOLKATA | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND BEING L1 BIDDER | |
| 2 | L2₹77.0 L+₹1.8 L (2.46%)Rejected-Finance 14 NATIONAL COMMERCE HOUSE BUILDING CHURCH ROAD SILIGURI DAJEELING WEST BENGAL 734001 | DARJEELING | WEST BENGAL | 734001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹79.3 L+₹4.1 L (5.48%)Rejected-Finance PO BINNAGURI PS BANARHAT DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹80.9 L+₹5.7 L (7.62%)Rejected-Finance PO BINNAGURI DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹85.3 L+₹10.1 L (13.5%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹93 L
EMD Value
₹1.6 L
Closing Date
5 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE BINNAGURI
HQ CWE BINNAGURI, BINNAGURI CANTT, JALPAIGURI, WEST BENGAL, PIN-735232
ADDN/ALTN AND SPL REPAIRS TO BLDG NO 2/R/19 (08 X HOUSES) ANS BLDG NO 1/R/6 (08 X HOUSES) AT BINNAGURI MIL STN UNDER GE NORTH BINNAGURI
2023_MES_610311_1
8082/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
BINNAGURI MIL STATION
AS PER NIT
8 documents required · 8 mandatory
₹1,000
GE (N) BINNAGURI
₹1.6 L
Yes
21 Oct 2023
22 Jul 2023
13 Sept 2023
22 Jul 2023
5 Sept 2023
30 Aug 2023
Amount
Roughening the surfaces of old concrete floor by picking, sweeping, cleaning and washing down with water to remove dust and brushing neat cement slurry with 3.0 kg of cement per Sqm, complete all as specified and directed by Engreer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as per specified and as directed by Engineer-in-charge.
S&F of coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in ready to make tile grouts of approved make to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as per specified and as directed by Engineer-in-charge.
M&L for 1st and premium quality coloured non-skid ceramic tiles joint free, ceramic digital coloured matt finish (shed, pattern & design as approved by GE) of 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.42 sqm but not exceeding 1 sqm, in floors etc set and jointed in neat cement slurry and pointed in pointed in ready to make tile grouts of approved make to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as per specified and as directed by Engineer-in-charge.
All as per item No 4 above but as in skirting / dado, complete all as specified and as directed by Engineer-in-charge.
M&L for 75 mm thick PCC (1:4:8) type D2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring/ hard standing complete all as specified and as directed by Engineer-in-charge.
M&L for 10mm thick rendering in cm(1:4) on fair faces of brick work or concrete surfaces, complete all as specified and as directed by Engineer-in-charge.
M&L for coloured glazed digital ceramic tiles of size 300x450mm/300x600mm of (shed, pattern & design as approved by GE) 7 to 8 mm thickness as on vertical surfaces such as skirting / dado and riser to steps set and jointed in neat cement slurry and pointed in pointed in ready to make tile grouts of approved make to match with the shades of tiles r, complete all as specified and as directed by Engineer-in-charge.
M&L for 18 to 20mm thick jet black granite machine cut, pre polished, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone as in kitchen platform, flooring and as vertical surfaces including grinding mirror polishing and moulding the exposed edges laid over 15mm thick screed bedding in cement mortar 1:6 complete all as specified and as directed by Engineer-in-charge.
M&L for acrylic polymer modified cementious coating with two coats over brick masonry / concrete surface before plastering complete all as specified and as directed”. Note : Application of polymer modified cementations coating shall be done before plastering to the internal / external wall surfaces and shall be done by authorized applicator only.
Providing holes to cooking platform of size 25 mm dia for inserting cooking gas pipe in suitable place as directed by Engr-in charge
Dismantling water tanks of capacity exc. 500 and not exc. 1000 ltrs, complete all as per specified and as directed by Engineer-in-charge.
S&F of rotational moulded polyethylene water storage tanks multi layered ISI Marked (cylindrical, vertical with closed top) of 500 Ltrs capacity hoisted and fixed in position including connecting up pipes securing access covers etc, complete all as per specified and as directed by Engineer-in-charge.
Disconnecting existing tanks of capacity exc 250 Ltrs and n. exc 500 Ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in same position after cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc, complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC (1:2:4) type B-1 ( using 20 mm grade crushed stone aggregate) as in water tank platforms, filling and mass concrete, complete all as specified and as directed by Engineer-in-charge.
S&F of 20 mm ball valves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142gms/ 20 mm - 210gms/25mm-455gms/ 40mm - 690 gms) and fixed in position complete all as per specified and as directed by Engineer-in-charge.
Taking up or down 15 mm bore steel tubing and connections, complete all as per specified and as directed by Engineer-in-charge.
Taking up or down 20 mm bore steel tubing and connections, complete all as per specified and as directed by Engineer-in-charge.
S&F of GI tube 15 mm bore medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-charge.
Refixing old 15 mm GI tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed by Engineer-in-charge.
S&F of GI tube 20 mm bore medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-charge.
Refixing old 20 mm GI tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed by Engineer-in-charge.
Taking down cement plaster on brick wall of any description, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer-in-charge.
"M&L for applying average 20 mm thick plaster in two coats (10+10mm) with readymix pre-packed proportioned dry mix mortar, blended with PP fibers, mixed with liquid water proofing compound on other than fair faces of brick wall or concrete surfaces additives on external surfaces including transporting of material, mixing, curing, scaffolding etc complete all as specified and as directed by Engineer-in-charge. Note: Liquid water proofing compound will be measured and paid separately as supply only.
Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed by Engineer-in-charge.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:6) and surface finished even and fair without using extra cement complete all as specified and as directed by Engineer-in-charge.
M&L for 5mm thick rendering plastering on fair faces of brick work or concrete surface as in celling in cement mortar (1:3) and surface even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing of new plastered surfaces of wall (internal & external) and applying two coats of cement-based wall care putty including preparation of surface to receive finishes (primer, distemper, paint etc.) complete all as specified and as directed by the Engineer-in-Charge and as per the manufacturer's instructions. Note: Preparation of new plastered surface and application of wall care putty to be carried out mechanically by authorised applicator and as per the manufacturer's instructions. Please refer Smart Painting clause mentioned in Particular Specification.
M&L for complete removal of existing treatment of wall (internal & external) and applying two coats of cement-based wall care putty including preparation of surface to receive finishes (primer, distemper, paint etc.) complete all as specified and as directed by the Eng-in-Charge and as per the manufacturer's instructions. Note: Removal of existing treatment and application of wall care putty to be carried out mechanically by authorised applicator and as per the manufacturer's instructions. Please refer Smart Painting clause mentioned in Particular Specification.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge.
M&L for preparing old plastered surfaces of ceiling and applying one coats of white wash complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engineer-in-charge.
M&L for brick work with sub-class `B' old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge.
All as per serial item No. 34 above but except bricks complete all as specified and as directed by Engineer-in-charge.
S&F in repair of sink with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460 bowl size 410 mm x 330 mm x 160 mm, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair wash basins, vitreous china, white, flat back, of minimum size 550mm x 400mm x 140mm including 32mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including S&F of fittings and brackets, sealing gap between wall and table top basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes. Waste pipes, waste fittings etc, with silicone sealant , complete all as per specified and as directed by Engineer-in-charge.
S&F in repairs 10 litres capacity, low level, symphonic type, white, plastic twin flushing cistern confirming to as per IS 7231 : 1994 with intel, ball valve, float and handle including brackets and 40mm nominal dia high density polyethylene pipes for flush pipe, complete all as per specified and as directed by Engineer-in-charge.
S&F in repairs vitreous china wash down, white, water closet pan (European type) (pedestal pattern) with ‘P’ or ‘S’ trap model with P or S trap, including plastic / PVC seat cover to match with colour of WC, closed pattern with flat bottom & cover and chromium plated mild steel or aluminium anodized hinging device including connecting to trap and flushing pipe, anti- syphonage pipe etc and screwed with brass screws and embedded in floor, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of vitreous china squatting pan Orissa pattern size 580x 440mm white with integral foot rest complete incl provision of lime concrete bedding, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair 15 mm bore fancy type bib taps long body cast copper alloy 15 mm bore with fancy chromium plated screwed down, screwed for iron pipe or for brass ferrule, complete all as per specified and as directed by Engineer-in-charge.
S&F 15 mm bore fancy type 2 way bib taps cast copper alloy 15 mm bore chromium plated screwed down, screwed for iron pipe or for brass ferrule, complete all as per specified and as directed by Engineer-in-charge.
S&F in repairs of stop valves fancy type cast copper alloy, chromium plated with long shank and cup (concealed type) for 15mm bore pipe, screwed both ends including necessary fittings such as sockets for pipe or for union, complete all as per specified and as directed by Engineer-in-charge.
S&F 15 mm bore fancy type wall mixer with 115 mm long bend pipe for connection to overhead shower (with bush and piston diverter fitting) with aerator, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of 15mm dia PVC connection pipe with PTMT nuts of length 600mm complete all as specified and as directed by Engineer-in-charge.
S&F in repair 15mm bore pillar taps swan neck cast copper alloy, with capstan heads, chromium plated, screwed down, fancy high pressure, with or without lettred ‘HOT or COLD’ with long screwed sunk and fly nuts complete all as per specified and as directed by Engineer-in-charge.
S&F in repair 15 mm bore fancy type angular valve cast copper alloy screwed down, high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions complete all as per specified and as directed by Engineer-in-charge.
S&F of Brass Chromium plated tubular towel rail, 20 mm dia., D Type, 60 cm long between flanges complete all as per specified and as directed by Engineer-in-charge.
S&F of glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chomium plated bracket guard & railing 60 cm long, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of stainless steel Soap dish, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of CP towel ring square shape with round flange, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of 0.63 mm thick stainless steel plate rack of size 31"x30"x10", complete all as per specified and as directed by Engineer-in-charge.
S&F in repair 15mm bore stainless steel overhead shower square shape sleek design of size 100 x 100mm with chromium plated overhead shower arm for 50mm long with wall flange , complete all as per specified and as directed by Engineer-in-charge.
S&F 15 mm bore fancy type health faucet with stainless steel pipe and hose , complete all as per specified and as directed by Engineer-in-charge.
S&F in repair 75mm PVC (SWR) floor trap including jointing with solvent cement complete all as per specified and as directed by Engineer-in-charge.
S&F in repair 100mm dia SS grade 304 cockroach type floor trap (grating, inner & outer filter with frame) fixed with cement mortar (1:4) including all accessories complete all as per specified and as directed by Engineer-in-charge.
S&F in repair stainless steel (AISI- 304 grade) square grating (flat slotted grating with frame of size 150mm x 150mm) complete all as per specified and as directed by Engineer-in-charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as per specified and as directed by Engineer-in-charge.
S&F of 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, complete all as per specified and as directed by Engineer-in-charge.
S&F of PVC (SWR) 110 mm bore bends complete all as per specified and as directed by Engineer-in-charge.
S&F of 110mm dia PVC (SWR) branch piece single (single 'Y') equal or unequal with acess door complete all as per specified and as directed by Engineer-in-charge.
S&F of 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door complete all as per specified and as directed by Engineer-in-charge.
S&F of 110mm dia PVC SWR vent cowl complete all as per specified and as directed by Engineer-in-charge.
S&F of 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, complete all as per specified and as directed by Engineer-in-charge.
S&F of PVC (SWR) 75 mm bore bends complete all as per specified and as directed by Engineer-in-charge.
S&F of 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door complete all as per specified and as directed by Engineer-in-charge.
S&F of 75 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as per specified and as directed by Engineer-in-charge.
Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm each and removing from site, complete all as specified and as directed by Engineer-in-charge.
Refixing shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each, complete all as per specified and as directed by Engineer-in-charge.
S&F for pressed steel frames for doors with one or more rebates including provisioning of necessary lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 125 x60 mm including one shop coat of priming , complete all as per specified and as directed by Engineer-in-charge.
S&F for pressed steel frames for doors with one or more rebates including provisioning of necessary lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 105 x60 mm including one shop coat of priming , complete all as per specified and as directed by Engineer-in-charge.
M & L for providing plain cement concrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work, complete all as per specified and as directed by Engineer-in-charge.
S&F of 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as per specified and as directed by Engineer-in-charge.
S&F factory made 35mm thick machine pressed architects veneer designer ply lam both side flush door shutter solid core construction with block board core incl 5mm thick leakwood lipping alround , complete all as per specified and as directed by Engineer-in-charge.
S&F of factory made partly glazed i.e. upper panel will be wire mesh fitted externally in the clear space & lower panel will be plain colour PVC sheet 5mm thick PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail,; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as per specified and as directed by Engineer-in-charge.
S&F of floor door stopper 14cm long of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor complete all as per specified and as directed by Engineer-in-charge.
S&F of 100 mm butt hinges stainless steel, complete all as per specified and as directed by Engineer-in-charge.
S&F stainless steel grade 304, 200mm long barrel tower bolt (ISI marked) fixing, complete all as per specified and as directed by Engineer-in-charge.
S&F stainless steel grade 304, 150mm long, decorative type pressed handle (ISI marked) , complete all as per specified and as directed by Engineer-in-charge.
S&F stainless steel grade 304, 300mm long stainless steel sliding door bolt plate type decorative (ISI marked) with bright bolt not less then 12mm die with and incl min of 6 bolt and nuts, four on bolt plate and two on staple fixing complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated wood or wood based surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of old painted surfaces of wood and wood based materials of any description, not otherwise described and applying one coat of synthetic enamel paint over 10 cm width or girth, complete all as per specified and as directed by Engineer-in-charge.
Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each and removing from site, complete all as specified and as directed by Engineer-in-charge.
S&F of factory made single extruded WPC (wood polymer composite) solid door/window/ceosetory windows & other frames/ chowkhat of size 45x85 mm coprising of virgin PVC polymer of K value 58-60 (Suspension Grade) , calcium carbonate and natural fibers (wood powder /rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum , screw withdrawal strength of 2200 N (Face) & 1100 N (Edge) Minimum compressive strength of 58 N/mm2 , modules of eleasticity 900 N/ mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasterners of required dia and lenght complete as per direction fo Engineer-In-Charge (M.S. hold fast/lugs or SS dash fasteners shall be paid for separaterly), complete all as specified and as directed by Engineer-in-charge. Note : For WPC solid door/ window frames minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus sides shall be acceptable but no extra payment on this account shall be made
S&F of factory made solid panel factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of Curtain rod of stainless steel 25mm dia, chromium plated with fixing brackets, stops, rollers etc. complete all as per specified and as directed by Engineer-in-charge.
S&F of stainless steel curtian rod holding brackets heavy duty fixed to wall with stainless steel screws complete all as per specified and as directed by Engineer-in-charge.
S&F of stainless steel finial type stop end suitable for curtian rod 25 mm dia complete all as per specified and as directed by Engineer-in-charge.
S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S&F of 125 mm long aluminium handles, cast type, anodised, complete all as per specified and as directed by Engineer-in-charge.
M & L for providing & fixing factory made solid PVC cup board frame of size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5 mm thick prelam/plain colour PVC sheet reinforce with 19mm x 19mm MS square tube of 19 gauge thickness throughout the frame and metre cut at two corners and jointed with 2 nos of 150mm long brackets of 15mm x 15mm MS square tubes.The door frame shall be fixed to the wall using 100mm long MS screws through the frame by using PVC fasteners. A minium 4 nos of screws to be provided for each vertical memberand minium 2 nos of screws to be provided to the horizontal mmember etc., complete all as per specified and as directed by Engineer-in-charge.
M & L for providing & fixing factory made solid PVC cup board shutter (Flush type) of 24 mm thick made from co-extruded 3 layer regid PVC foam sheet (single extruded) with density not less than 600kg/cbm outer layer (.8-1mm) thick should be of rigid PVC with density of not less than 1400kg/cbm manufactured byan ISO 9001-2015 certfied company. Door should be water proof, turmite proof, fire retardant and having good screw holding capacity, complete all as per specified and as directed by Engineer-in-charge.
S&F of providing and fixing factory made PVC shelf/partitation of required size consisting of 20mm thick Solid PVC Sandwich Panel with lmm Plain PVC Sheet on both sides suitably fixed in M.S. angle frame work as per specification & drawing, complete all as per specified and as directed by Engineer-in-charge.
S&F of 150 mm Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as per specified and as directed by Engineer-in-charge.
S&F of 75 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
M&L for Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed, complete all as per specified and as directed by Engineer-in-charge.
S&F of Stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or galvanized wire staples complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of Stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or galvanized wire staples complete all as per specified and as directed by Engineer-in-charge.
S&F of Powder coated aluminium window sliding type three track (2 glazed & one gauzed shutter ) aluminium sections weighing not less than 1.25 kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazing cleats, rubber packing , screws, handle, locking arrangement and 5.5mm thick plain/tinted glass and aluminium mosquito proof gauge including taking down of old existing steel window and making good disturbed surfaces of wall complete all as per specified and as directed by Engineer-in-charge.
S&F of Powder coated aluminium louvered ventilators of size n exc 0.50 Sqm area with glass louvers, without sash bars of aluminium sections weighing not less than 0.605kg/m for frame of size 40x20x2mm including necessary jointing cleats, glazing cleats, rubber packing , anodised aluminium snap beading,screws, anodised aluminium fittings and 5.5mm thick tinted glass fixed in panels with suitable locking arrangements including taking down of old existing steel ventilator and making good disturbed surfaces of wall complete all as per specified and as directed by Engineer-in-charge.
M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel or iron surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide, primer over 10cm width or girth complete all as specified and as directed by Engineer-in-charge.
M&L for applying two coats of Synthetic enamel paint over pre primed steel surfaces over 10cm width or girth incl necessary cleaning/washing complete all as specified and as directed by Engineer-in-charge.
Demolition of unreinforced cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge.
M&L PCC (1:3:6) type C2 using 40mm graded stone aggregate, 75 mm thick in plinth protection laid in panels and finished even and fair including necessary formwork complete all as specified and as directed by Engineer-in-charge. Note : Joints 12 mm wide to the full depth of PCC shall be provided at every 3 meters and at every change of direction and shall be filled with mixture of Bitumen and sand 1:3 by weight. Contractor should quote rate inclusive of joint filling complete.
M&L for for PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in coping /benching to sides of foot path finished cement concrete surface even & fair etc complete all as specified and as directed by Engineer-in-charge.
S&F in repair of 0.56 mm thick Plain, Aluminium sheeting, Alloy 31000 H4 bend to shape fixed with pins to door shutter to prevent water splashing,ridges, hips,valley gutters, drip and straight flashings over crumple joints complete all as specified and as directed by Engineer-in-charge.
M & for water proofing treatment to sunken floor with the following course of treatment/ specification: (i) Cleaning top surface of floors /slabs and laying 50 mm thick (avg) PCC of grade M10 (Nominal mix) , mixed with WPC as per manufactrrer's instruction laid in slope 1:20 towards spouts including coveting corners (ii) 15 mm thick plastering in CM (1:4) on sides mixed with WPC as pe rmanufacturer's instruction. (iii) Applying 1st layer of slurry @ 0.488 kg / sqm mixed wth acrylic based polymer modified cementious compound @ 0.253 kg /sqm This layer shall be allowed to air cured for 4 hrs. (iv) applying 2nd layer of slurry @ 0.242 kg/sqm mixed with accrylic based polymer modified cementenous compound @ 0.126 kg/sqm.This layer shall be allowed to air cured for 4hrs followed with water curing for 48 hrs. (v) Applying a coat of industrial bitumen 85/25 penetration @ 1.50 kg/sqm on plastered and concrete surfaces (vi) Providing 150 micron thick polyutethene paint in two coats (each of 75 micron measured dry on dry surface over a coat of PU primer including preparation. (vii) 2 Nos 32mm bore GI medium grade 450mm long spout ,to be provided through external wall to drainout accumulated water. (viii) Sunken floor shall be tested for water tighness by filling water for 72 hrs before and after treatment work is carried out and ensure that no leakage /seepage exists (ix) Sunken portion shall be filled with lean concrete 1:4:8 type D2.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed by Engineer-in-charge.
M&L for RCC (nominal Mix) type A-1, 1:1.5:3 (20 mm graded aggregate) as in as in chajjas, beam, column, roof, landing, shelf, plateform, facia and like, complete all as per specified and as directed by Engineer-in-charge.
M&L for Formwork to chajjas, facia, Shelf, roof, landing and like for rough finished surface of concrete flat, complete all as per specified and as directed by Engineer-in-charge.
M&L for welded steel wire fabric of weight n. exc 4 kg per Sqm supplied and fixed complete to wood or steel member, complete all as per specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 6 mm to 8 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality confirming to Fe-410-S 0r Fe-410-O, complete all as per specified and as directed by Engineer-in-charge.
Use and waste of formwork to edges of rough finished surfaces of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, complete all as per specified and as directed by Engineer-in-charge.
M&L for machine cut kota stone slab flooring 18-20 mm thick, for staircase steps (treads) in single piece (of length not more than 1200mm), jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including provn of two Nos 3x3 mm grooves at tread of each step laid over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as specified and as directed by Engineer-in-charge.
M&L for machine cut kota stone 15-20 mm thick for staircase steps (risers) in single piece (of length not more than 1200mm), jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and beewax polishing over 10 mm thick bedding layers in CM 1:4, complete all as specified and as directed by Engineer-in-charge.
M&L for diamond cut kota stone slab flooring 18-20mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and mirror polishing to give high gloss finish laid over 15 mm thick screed bed or bedding layers in CM 1:6, complete all as specified and as directed by Engineer-in-charge.
M&L for machine cut kota stone skirting 15-20 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over 10 mm thick bedding layers in CM 1:4, complete all as specified and as directed by Engineer-in-charge.
Taking down tarfelt with cement plaster from roof surfaces and lowering and removing the same to a distance exceeding 50 m and not exc. 100 m including roughening of old concrete suirface of roof by wire brushing and cleaning the surface to remove all loose dust etc, complete all as specified and as directed by Engineer-in-charge.
M&L for 10mm thick screed bed or bedding layer in cement mortar (1:4) mixed with WPC in order to maintain proper slope over existing roof surfaces for laying water proofing treatment over roof, finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge. (Note: Water proofing compound shall be measured and paid perarately under relevant item of schedule 'A').
M & L PCC (1:2:4) type B1 (20mm graded aggregate) as in roof kerbs, slightly rounded or chamfered on edges, mixed with water proofing compound 200 ml per beg of cement or as per manufacturer instructions finished even and smooth on exposed concrete surface without using extra cement, complete all as specified and as directed by Engineer-in-charge. (Note: Water proofing compound shall be measured and paid perarately under relevant item of schedule 'A').
M&L for waterproofig Coating with polyurethane based water proofing liquid membrane of approved make to be applied by brush with multi coats with minimum dry film thickness of 1mm and shall be cured by reaction with atmospheric moisture to give a tough elastomeric waterproof membrane, complete all as specified and as directed by Engineer-in-charge. Note: the above treatment will be carried out by authorised applicator of approved firm/company.
M&L for applying two coats of Acrylic smooth exterior anti-fungal paint of shade as approved by GE over a coat of primer over finished putty surfaces of wall complete all as specified and as directed by the Eng-in-Charge and as per the manufacturer's instructions. Notes:- 1. Application of new finishes to be carried out mechanically by authorised applicator and as per the manufacturer's instructions. Please refer Smart Painting clause mentioned in Particular Specification. 2. Application of putty and preparation of surface to receive the paint shall be measured and paid separately under relevant item of this schedule.
M&L for applying two coats acrylic-based distemper of shade as approved by GE over a coat of primer over finished putty surfaces of wall complete all as specified and as directed by the Eng-in-Charge and as per the manufacturer's instructions. Notes:- 1. Application of new finishes to be carried out mechanically by authorised applicator and as per the manufacturer's instructions. Please refer Smart Painting clause mentioned in Particular Specification. 2. Application of putty and preparation of surface to receive the distemper shall be measured and paid separately under relevant item of this schedule.
S&F of 18mm thick marine plywood laminated of any colour with high glossy acrylic sheet of 3mm thick, grade I as per IS 14587 for frame and shutter for kitchen cabinets complete all as specified and directed by Engineer-in-charge.
S&F of round stainless steel cabinet knobs / drawers handles dia of 27mm complete all as specified and directed by Engineer-in-charge.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand and including 75mm thick PCC 1:3:6 (type C-2) as in sub base , complete all as per specified and as directed by Engineer-in-charge.
Demolition and breaking up including removing salt glazed stoneware pipe 150 mm bore (internal) with concrete bedding and haunching complete including necessary earth work as required complete all as specified and as directed by Engineer-in-charge.
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches n.exc 1.5m wide and n. exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n. exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and as directed by Engineer-in-charge.
M&L for precast cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces set in cement mortar 1:6, complete all as specified and as directed by Engineer-in-charge.
M&L for Reinforced concrete pipes of size 200 mm, class NP2, laid and jointed complete with collars, complete all as specified and as directed by Engineer-in-charge.
S&F of PVC (SWR) (Bore of pipe 200mm) pipes with working pressure 6 kg/cm2 single socketed, in any length with rubber ring joints fixed to walls with necessary clamps, complete all as specified and as directed by Engineer-in-charge.
S&F of 200 mm dia PVC (SWR) bends any radius fixed to PVC Pipes/Steel Gutters etc, complete all as specified and as directed by Engineer-in-charge.
M&L for concrete bed 1:3:6 type C2 (40 mm graded stone aggregate) to 100 mm dia. drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as per specified and as directed by Engineer-in-charge.
M&L for for PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in foundations/sub-base, filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
M&L for PCC 1:3:6 type C-1 (20mm graded stone aggregate) as in coping/benching for man holes, complete all as per specified and as directed by Engineer-in-charge.
M&L for PVC (SWR) gully trap 125/110 mm,setting and jointing with solvent cement, complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L rendering 20mm thick on other than fair faces of brick work or concrete block surface in cement mortar 1:4, surface to be finished even and smooth (without using extra lime or cement), complete all as specified and as directed by Engineer-in-charge.
M&L for concrete bed 1:3:6 type C2 (40 mm graded stone aggregate) to 150 mm dia. drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as per specified and as directed by Engineer-in-charge.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for pipe of internal dia. 150mm, complete all as specified and as directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius in cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge.
Taking down carefully old unserviceable copper/ aluminium point wiring (light, exhaust fan, socket or power) complete incl fittings such as switches, ceiling roses, pendants, regulators, bells, sockets, tube light fittings etc., and making good disturbed surface of walls & floors etc., complete all as specified and as directed by Engineer-in-charge.
M&L for point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with multi stranded copper conductor with proper colour coding drawn through and including non-metalic rigid PVC medium grade conduit and conduit accessories (IS marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multi stranded unsheathed copper conductor cable FR-LS (ISI marked) with proper colour coding as earth continuity conductor connected to common earth dolly, modular sheet steel sunken terminal box of appropriate size suitable for modular switch/fittings concealed in wall, with modular back plate, top cover fixed flush to wall for housing switches, socket outlets, fan regulators etc duly earthed including cutting chasses of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB’s or bus bar shall be done through proper size copper/brass thimbles complete for one light point controlled by one way switch , complete all as per specified and as directed by Engineer-in-Charge.
All as per serial item No. 145 above but for one ceiling/exhaust fan point controlled by one switch.
All as per serial item No. 145 above but for one socket outlet 5/6 AMPs on independent board.
All as per serial item No. 145 above but for one socket outlet 5/6 AMPs on same board.
All as per serial item No. 145 above above but for one Bell point controlled by one switch.
All as per serial item No. 145 above above but for one light point controlled by two way switch.
All as per serial item No. 145 above above but with 2.5 sqmm single core multistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed
S&F of modular switch, single pole, one way, 6 Amp, 1 module, 230 volts, complete all as specified and as directed by Engineer-in-charge.
S&F of modular switch, single pole, two way, 6 Amp, 1 module, 230 volts , complete all as specified and as directed by Engineer-in-charge.
S&F of Call bell ding dong muscial type, AC, 230 Volts, Single pole, complete all as specified and as directed by Engineer-in-charge.
S&F of modular bell push, one way, 6 Amp, 1 module, 230 volts complete all as specified and as directed by Engineer-in-charge.
S&F of modular shuttered socket outlet 5 Pin, 6 Amp, 2 Module, 230 volts complete all as specified and as directed by Engineer-in-charge.
S&F of modular shuttered socket outlet 6 Pin, 6/16 Amp, 2 Module, 230 volts complete all as specified and as directed by Engineer-in-charge.
S&F of modular, single pole, one way, 16 Amp 1 Module, 230 Volts complete all as specified and as directed by Engineer-in-charge.
S&F of ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
S&F of lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-charge.
S&F of LED white glass Lamp 1x9 Watt 230V Base-22, complete all as specified and as directed by Engineer-in-charge.
S&F of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required, complete all as specified and as directed by Engineer-in-charge.
S&F of LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed by Engineer-in-charge.
S&F of LED light fitting 1x9W/1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-charge.
Taking down carefully Ceiling fan from its original position and refixing / hanging after plaster work incl painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc, complete all as specified and as directed by Engineer-in-charge.
M&L for sub main wiring two run of size 6 sqmm PVC insulated electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with 6.0 sqmm PVC insulated copper conductor earth wire in PVC conduit of suitable size (two run of 6 sqmm cable and one of 6.0 sqmm wire and one run of PVC conduit / casing caping will be measured as one unit) including dismantling of existing unserviceable submain wiring complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB TPN 4 way double door DB with 200 amps rated bus bar, 415 Volt IP-20 protection suitable for fixingincluding taking down old unserviceable one, complete all as specified and as directed by Engineer-in-charge.
S&F of 415V 10KA 'C' curve miniature circuit breaker (MCB) of Triple pole 25 to 63 Amps and current carrying capacity in the DB complete with connection testing and commissioning including taking down old unserviceable one, complete all as specified and as directed by Engineer-in-charge.
Supply and fix double door sheet metal enclosure powder painted for MCB SPN 8 way 240 volt DB with din rail and bus bar including making good to the disturbed surface matching with the existing including taking down old unserviceable one, complete all as specified and as directed by Engineer-in-charge.
S&F of amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning including taking down old unserviceable one, complete all as specified and as directed by Engineer-in-charge.
S&F of amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 6 To 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning including taking down old unserviceable one, complete all as specified and as directed by Engineer-in-charge.
S&F of factory made sheet metal box made out of 2 mm thick MS sheet of size not less than 600 X 900 X 200 mm with double door hinged shutter and locking arrangement for fixing DBs, KWH Metter etc flashed / grouting on wall incl painting with two coated of powder coated paint over a coat of red oxide primer with suitable glass vision panel of each meters shall be provided in the door to easy meters reading , including taking down old unserviceable one, complete all as specified and as directed by Engineer-in-charge.
S&F of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including taking down old unserviceable one, complete all as specified and as directed by Engineer-in-charge.
Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, includig necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 5 of SSR Part- I including testing including taking down old unserviceable one, complete all as specified and as directed by Engineer-in-charge.
S&F of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm, complete all as specified and as directed by Engineer-in-charge.
S&F of electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc., complete all as specified and as directed by Engineer-in-charge.
S&F of 15 mm stop valves, fancy type, chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as per specified and as directed by Engineer-in-charge.
S&F of 15 mm bore bib taps, fancy type, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge.
Taking out old unserviceable cable of any size carefully from trenches ofter disconnecting electric connection, GI pipe protection, with and including separating serviceable bricks & set aside and removing un-serviceable bricks from site complete all as specified and as directed by Engineer-in-charge. Note : The excavation and earth work shall be mesured and paid separately under relevant item of Schedule.
Supply, laying, jointing & testing of 25 Sqmm, 3.5 Core XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100Volt grade on walls with fixing acessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete all as specified and as directed by Engineer-in-charge. Note - Earthwork, sand cushioning, bricks, GI pipe, etc. shall be measured and paid separately.
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 8cm deep before laying and 15cm covering above the top edge of cable after laying, complete all as specified and as directed by Engineer-in-charge.
Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
Laying only Old bricks for protection of LT UG cable, complete all as specified and as directed by Engineer-in-charge.
M & L for horizontal boring across the existing road without disturbing the road surface for inserting GI pipe, complete all as specified and as directed by Engineer-in-charge. Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch 'A'.
S&F of GI tube 50 mm bore light grade ISI marked for protection of cable including necessary joints with all fitting, laid in trenches complete all as specified and as directed by Engineer-in-charge.
S&F of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 200 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/ BOQ.
KAMALA INDUSTRIES
MESSRS SEN BROTHERS
L. B. SHARMA
M/s. RAMPHAL GARG
ANIL ENGINEERING CO
M/S East India Traders
MS SHRI B.C. DAS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .