Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹12.0 L+₹2.4 L (25.0%)Accepted-AOC | L2 | Accepted-AOC As per NIT | |
| 2 | L1₹9.6 LRejected-Finance | L1 | Rejected-Finance As per NIT | |
| 3 | L3₹12.9 L+₹3.3 L (34.4%)Rejected-Finance | L3 | Rejected-Finance As per NIT |
Tender Value
₹12.9 L
EMD Value
₹16,150
Closing Date
20 May 2023, 3:00 pmClosed
SO ENM
CRS BARKAKANA
Complete Concealed rewiring along with supply and erection of Acrylic letter Sign Board with LED Light backlight of main gate of Area Finance Manager Office Building along with power provision cum shed lighting at csr/motorcycle shed at CRS Barkakana
2023_CCL_278768_1
CRS/BRK/ SO(EnM)/NIT/2023-24/363
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
CRS BARKAKANA
Please refer Tender documents.
2 documents required · 2 mandatory
₹16,150
27 Jun 2023
9 May 2023
22 May 2023
9 May 2023
20 May 2023
9 May 2023
9 May 2023 - 15 May 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required .
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required. 2x2.5 sq.mm +1x2.5 sq. mm earth wire.
Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required. 2x 4 sq.mm +1x 4 sq. mm earth wire.
Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required. 2x 10 sq.mm +1x 6 sq. mm earth wire
Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing 5 Amps to 32 Amps rate 240 V ‘C’ series MCB suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. Single Pole.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double door.
Supplying and fixing following rating , double pole ( single phase and neutral) 240V residual current circuit breaker (RCCB) , having a sensitivity current up to 300 millanmperes , in the existing MCB DB complete with connections, testing and commissioning , earthing etc as required. 40 amps.
Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 +24) Double door.
Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100A , 30KA, FPMCCB
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc. as required.
Supplying and fixing brass batten /angle holder including connection etc. as required.
Supplying, installing, testing and commissioning of following capacity End Feed Unit made of 1.6mm thick sheet steel enclosure duly painted with powder coating to existing rising mains complete with TPN disconnector FSU and HRC fuses, mounting stands, cable end box, brass compression gland, connections, earthing etc. as required. 200 A TPN
Earthing with copper earth plate 600 mm x 600mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required.
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connection etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Erection of metallic pole of following length in cement concrete 1:3:6(1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc as required. Above 6.5 metre and up to 8.0 metre.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing following capacity busbar chamber with 4 strip of suitable size made of copper , heavy duty complete with all accessories including connections, earthing the body, etc as required. 200 Amps.
Providing and fixing following capacity 2 pole/ 4 pole ON/OFF-load changeover switch with side handle potation, in sheet enclosure in existing metal board including drilling holes in metal board , making connection , earting the body etc. as required. 200 amps, 4 pole.
Providing of Recess Mounting LED Panel light 2x2 (36 watt).
Providing of Recess Mounting LED Round Down Light (18/20 watt).
Providing and fixing Acrylic letter with LED Sign Board of size 15 ft. x 3ft. made out of 3 mm thick ACP sheet to lit the name in English letter made of acrylic along with structure frame etc complete .
Providing and fixing of LED Post top light (Gate Light fitting.) 36 watt.
Total impact of GST for the purpose of CTC
M/S B.N. PANDEY
M/S LAXMI AGENCY
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_288593.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .