Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹4.0 Cr
EMD Value
₹4.0 L
Closing Date
30 Sept 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Construction of volleyball court, boundary wall, and SITC of external stadium flood lighting work at Biju Patnaik Hockey Stadium for RSPL at Rourkela.
NBCC/SBG/OD/CG/NIT/24-25/013
NBCC/SBG/OD/CG/NIT/24-25/013
Open Tender-Domestic
Electrical Work
Sundargarh, Odisha
₹11,800
₹4.0 L
30 Sept 2024
12 Sept 2024
30 Sept 2024
30 Sept 2024
15 Oct 2024
Grand Total A 27,34,398.99
Grand Total B 23,45,367.49
Grand Total C 3,47,39,007.45
Providing and laying in position cement concrete of specified grade
14 4.1 excluding the cost of centering and shuttering - All work up to plinth level :
Digitally signed by Rakesh
2023 Rate Amount
S.No. DSR 2023 Description of Indicative Items Unit Qty
excluding without GST
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources :
14.1 4.1.8 8 graded stone aggregate 40 mm nominal size derived from natural
Providing and placing in position 100 mm thick factory made
machinebatched & machine mixed Precast RCC Rectangular Covers on
drains of footpath of various sizes, of M-25 grade cement concrete for
RCC work, including cost of centering, shuttering, reinforcement of 8 mm
dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways ,
neat cement punning on finished surface, properly
encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly
painted over priming coat , reinforcement to be welded at edges with MS
sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of
cartage, all leads & lift, handling at site etc. all complete as per direction of
Engineer-in-Charge.
Providing and laying 60mm thick faciory made cement concrete
interlocking paver block of M -30 grade made by block making machine
with strong vibratory compaction, of approved size, design
& shape, laid in required colour and pattern over and including 50mm thick
compacted bed of coarse sand, filling the joints with line sand etc. all
complete as per the direction of Engineer-in-charge. sqm 823.73 120.00 98847.46
Providing and fixing G.I. chain link fabric fencing of required width in
mesh size 50x50 mm including strengthening with 2 mm dia wire or
nuts, bolts and washers as required complete as per the direction of
Engineer-in-charge. Made of G.I. wire of dia. 4 mm, PVC coated to
outer dia not less than 5 mm in required colour and shade sqm 904.32 78.00 70537.12
Total of Schedule Items 1414578.23
NON SCHEDULE ITEM
Rate NS Amount
S.No. NS Code Description of Indicative Items Unit
without GST without GST
Plastic Chairs in HDPE material including fixing in all respect as per
direction of Engineer in charge Nos 2118.64 26.00 55084.75
Volleyball Post
supplying and Installation of Removable Volleyball Post comes with dia 76
mm outer pole with red powder coating and Dia 60 mm adjustable upright
22 NSI 2 with zinc plating. Height can adjust 2M to 2.5m by manual pin locking
Volleyball post fixed by using ground sleeves with holdfastand concrete.
Manual winch is provided for tightening the net. Pair 122881.36 1.00 122881.36
Tournament Volleyball Net
9.5 to 10 m in length and 1 m wide including fixing in all respect as per Nos 5084.75 1.00 5084.75
24 NSI 4 direction
Umpire's of Engineer
Chair in charge
with Ladder Nos 25423.73 1.00 25423.73
25 NSI 5 Acrylic distemper paint for Ground marking lines including marking in all Job 16949.15 1.00 16949.15
SITC of as per direction
Volleyball of Engineer
Electronic in charge
LED metal rectangular remote operated
26 NSI 6 Score Board complete in all respect as per direction of Engineer in charge
NS-7 Supply, installation, testing and commissioning of Acreylic signage as per sqft 2245.76 35.00
the subject matter to be written as finalized/ directed by client/NBCC with
requisite support frame/handing arrangement including proper
illumination (lights to be fixed within the letter), with necessary screw,
accessories, electrical wire connection, switch, plug etc. complete in all
respect as per direction of Engineer in charge(minimum 02 years
replacement warranty shall be provided by the LED backlid manufacturer
as per the list of make of material) 78601.69
Total of Non Schedule Items 323347.46
Total (Schedule + Non Schedule) Items 1737925.69
Digitally signed by Rakesh
Electrical Volleyball court
AS PER DSR-2022 AS PER MARKET RATE
S.NO DESCRIPTION OF ITEM UNIT QTY. Rate without AMOUNT Rate without
ITEMS AMOUNT (RS.)
GST (RS.) GST
SUB HEAD-I : EXTERNAL LIGHTING
1) NS-1 Supply of following sizes XLPE insulated (Heavy duty) Aluminium or Copper conductor armoured cables
suitable for working voltage upto and including 1100 Volts complete as required and as per specifications.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size
2 direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as
DSR-2022- Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size
in the existing RCC/ HUME/ METAL pipe as required.
DSR-2022- Upto 35 sq. mm
4) NS-2 Termination of the following sizes of XLPE insulated Aluminium/ Copper conductor cable including providing
terminal lugs,double compression gland , crimping the joints ,providing insulation tape,effecting terminal
connections to the equipment complete as required.
a 2 x 6 sq,mm, Al conductor cable Nos. 12 694.74 8,336.85
5) Supply, laying and termination of the following sizes of 650/1100 volts grade PVC insulated copper conductor
wires in existing conduits including end terminations with copper lugs.
a. DSR-2022- 3 x 2.5 sq.mm. Copper conductor ,PVC insulated PVC sheathed wires RM 80
b. DSR-2022- 2 X 6 sq. mm PVC insulated copper conductor wire along with 1 X 2.5sq.mm PVC insulated copper conductor RM 110
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC
7 collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling
etc as required.
DSR-2022- 100mm dia
8) NS-3 Supply,fixing and laying of Heavy duty PVC pipes complete buried in floor with joints and other accessories as
a) 63 mm dia, 2mm thick RM 110 79.36 8,729.15
10) NS-4 Supply of LED Sports 500W Floodlight with high-power LED shall be made of Single/Modular housing
noncorrosive aluminium die cast PC Modular lens plate with toughened glass to ensure better uniformity of
lighting distribution.,suitable for 15/30/10 degrees. All Lens should be screw fitted on the housing to ensure the
proper mechanical alignment to increase the rigidity of fixing of lens to get the unify photometry distribution.
Designed heat sink for efficient thermal management along with safety chain. The luminaire should be IP66 and
IK07 suitable and detachable separate compartment for driver considering ease of maintenance. Same housing
should be compatible with different beam angle. LED Floodlight luminaire shall have CRI > 70 and CCT >
5700 K (tolerance on CCT: +/- as per ANSI C78:377A), SDCM (Mac Adam Ellipse): < 5. The system Efficacy
of the luminaire shall be typical > 110 Lumen/Watt. The luminaire shall be designed to ensure lumen
depreciation of up to 30% over 50K burning hrs at designed ambient temperature 35 Deg Celsius. The driver
shall have a power factor of >0.95. THD of the driver < 10%, EMI/EMC compliance. The driver shall have Over
Temperature, Under Voltage/Short Circuit, Over Voltage/Open Circuit and Output failure protections, with an
Efficiency of > 90%. Driver can withstand high voltage up to 440V for > 24 Hrs. The floodlight and external
driver (should be potted for better reliability) shall comply to Class-I electrical insulation class. Inbuilt driver
surge protection of minimum 6KV must . Driver is having voltage ripple < 1% (peak to average) and output
current ripple < 5% (peak to average). Driver is having over heating protection circuit (thermal fold back > 75
Deg Celsius) which ensure the safety of luminaire and surrounding. The average lumen maintenance summary
needs to be submitted at the different case temperature (soldering point) at Ts: 55, 85 and 105 Deg Celsius. All
plastic parts, cable used etc. shall be UV protected. Input cable of luminaire should be rubber as per IS 10322
(part 5/section 5). The luminaire should comply with all the required IEC & IS standards. LM79 (C type Gonio
Photometry IES LM 79 -19) & LM80 report must be submitted from a NABL accredited lab. Luminaire and
Driver must have BIS certificate.
16) Feeder Piller (volleyball Ground)
NS-5 Design, manufacture,Supply, Installation, testing and commissioning at works of Double door panel fabricated
with minimum 2mm thick CRCA sheet, Conform to IS Specification, with IP-55 enclosure protection, as per IS-
2137(Revised), floor mounting free standing on a suitable massanory pedestal outdoor type panel,provided
with hinged detachable and lockable outer opening doors with the following incoming/outgong MCCB/ MCBs
mounted therein including making connections/ interconnections, earthing, painting etc. as required.The panel
shall have canopy arrangement on the top.All MCB to be C curve .
a. Feeder Pillar - X
The incoming shall comprise the following :-
1 No 63A FP MCB, 16 KA service breaking capacity with heavy duty solid neutral link alongwith Earth fault
relay and CBCT.
Metering for incoming:
Digital Multifunction meter (MFM-4) with RS-485 communication port for measurement of PF, V, A & Hz ,
equivalent to EM6459, with CT as required.
Phase indicating lamps RYB with 2 Amps SP MCB back up.
80 Amps TPN Aluminium Bus Bars of suitable length Bus bars shall be colour coded and insulated by heat
shrinkable sleaves & clip on shrouds for joints. The current density of Bus bar shall be 0.8 sq.mm./amp.
Outgoing (All MCB shall be suitable for motor duty & with heavy duty detachable solid neutral link ):
ii. 20 nos 25A DP MCB 10 KA breaking capacity controlled by and including providing 40 DP MCCB, 40 A DP
contactor and Timer.
NS-5. Feeder Pillar - X described as above and all as per specification. Set 1 1,22,881.36 1,22,881.36
NS-6 Supply, installation, Testing & commissioning of Octagonal G.I. poles with galvanised mounting bracket with nos 6 11,186.44 67,118.64
required accesseries to accomodate street light fitting complete with base plate, finial taper
plug, bolts, nuts, junction box within the pole for incoming and outgoing cables (size up to 2 C x 6 Sqmm) and a
10 amps SP MCB and screws as specified in type HM1107 P - 9.0 mtr. Long.
Bottom diameter- 150 mm Top diameter- 75 mm Nos of foundation bolts- 04 PCD of foundation Bolts- 240x240
mm Bolt diameter - 16mm Rate shall included the cost of inbuilt junction box (weather proof), (6- 32A) MCB to
fitting with 2.5 sq mm copper wires (2 Nos. 2.5 Sq.mm copper wire for phase & 1 No. 1.5 Sq.mm copper wire
for earthing) complete with base plate made from concrete civil foundation works . The pole shall be painted
with final PU Paint as required. 9.0 m long pole with double arm for mounting the light .The work shall include
all civil and allied work complete in all respect as per direction of engineer in charge
9.0 m long pole with single arm for mounting the light .
20) Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry
enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ Set 2 6,332.20 12,664.41
coke and salt as required.
21) Supply and fixing in position the following G.I. tape/wires including providing all fixing accessories and effecting
proper connections.
a. DSR-2022- Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection
5.11 with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
b. DSR-2022- Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including RM 15 648.31
5.7 connection/ termination with GI thimble etc. as required.
AS PER DSR-2022 AS PER MARKET RATE
S.NO DESCRIPTION OF ITEM UNIT QTY. Rate without AMOUNT Rate without
ITEMS AMOUNT (RS.)
GST (RS.) GST
FANS & LIGHT FIXTURES:
1 NS-7 Supply, installation, testing & commissioning of 4 FT TUBE LIGHT Each 4.00 677.97 2,711.86
Supply installation testing and comissioning LED Tube, Wall / Surface / Celling Mounted, 10W(MIRROR
LIGHT), luminous flux of luminaire 900lm, IP 20,1200mm, Direct light emission, 230V, Electronic Control
Gear, 5700K, Satin Diffuser, L=600mm (Min)
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush
Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2
nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value
(CM/M/W) minimum 6.00, Air delivery
10 NS-9 minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic Each 4 2,372.88 9,491.53
regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers,
temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz,
single phase AC
Supply, earthing etc. complete as required.
Construction of Volley ball court, RR boundary wall and SITC of external lighting work at Biju Patnaik Hockey
Stadium for RSPL at Rourkela
2023 Rate Amount
S.No. DSR 2023 Description of Indicative Items Unit Quantity
excluding without GST
Earth work in excavation by mechanical means (Hydraulic excavator) /
manual means in foundation trenches or drains (not exceeding 1.5 m in
width or 10 sqm on plan), including dressing of sides and ramming of
bottoms, lift upto 1.5 m, including getting out the excavated soil and
disposal of surplus excavated soil as directed, within a lead of 50 m.
Filling available excavated earth (excluding rock) in trenches, plinth, sides
of foundations etc. in layers not exceeding 20cm in depth, consolidating
2 2.25 each deposited layer by ramming and watering, lead up to 50 m and lift
Centering and shuttering including strutting, propping etc. and removal of
form for all heights : 0.00
5.1 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete Sqm. 332.33 363.48 120795.49
Centering and shuttering including strutting, propping etc. and removal
of form for Lintels, beams, plinth beams, girders, bressumers and
Reinforced cement concrete work in beams, suspended floors, roofs
having slope up to 15° landings, balconies, shelves, chajjas, lintels,
bands, plain window sills, staircases and spiral stair cases above plinth
level up to floor five level, excluding the cost of centering, shuttering,
5.3 finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse
sand(zone-III) derived from natural sources : 3 graded stone aggregate
20 mm nominal size derived from natural sources).
Providing and laying in position specified grade of reinforced cement
5.1.2 concrete, excluding the cost of centering, shuttering, finishing and
reinforcement - All work up to plinth level : cum 7665.89 21.55 165169.26
Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete upto plinth level. kg 91.40 3954.60 361443.74
Providing and laying in position cement concrete of specified grade
14 4.1 excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources :
14.1 4.1.8 8 graded stone aggregate 40 mm nominal size derived from natural
Brick work with common burnt clay F.P.S. (non modular) bricks of class
15 6.1 designation 7.5 in foundation and plinth in:
15.1 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) cum 6246.31 43.20 269840.75
Brick work with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in superstructure above plinth level up to floor V level in
16 6.4 all shapes and sizes in :
16.1 6.4.1 Cement mortar 1:4 (1 Cement : 6 coarse sand) cum 7918.94 72.00 570163.73
Steel work welded in built up sections/ framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets,
gates and similar works kg 146.27 450.00 65822.03
13.1 12 mm cement plaster of mix : 0.00
Digitally signed by Rakesh
2023 Rate Amount
S.No. DSR 2023 Description of Indicative Items Unit Quantity
excluding without GST
Providing and fixing concertina coil fencing with punched tape concertina
coil 600 mm dia 10 metre openable length ( total length 90 m), having 50
nos rounds per 6 metre length, upto 3 m height of wall with existing angle
iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T.
reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain
18 16.53 horizontal, including necessary bolts or G.I. barbed wire tied to angle iron,
all complete as per direction of Engineer-in-charge, with reinforced barbed
tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of
165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre
(cost of M.S. angle, C.C. blocks shall be paid separately) metre
Total of Schedule Items 1987599.57
Digitally signed by Rakesh
SCHEDULE OF QUANTITIES FOR SUPPLY, ERECTION, TESTING AND COMMISSIONING
AS PER DSR-2022 AS PER MARKET RATE
DSR Rate without
S.NO DESCRIPTION OF ITEM UNIT QTY. Rate without AMOUNT Without GST
GST (RS.) AMOUNT (RS.)
EXTERNAL LIGHTING
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30
1 2.6 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth
lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not 115.20
exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and
lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm 4.00
nominal size derived from natural sources) cum 5772.88 23091.53
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
2.26.1 All kinds of soil Cum 96 107.46 10315.93
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering,
shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm
nominal size derived from natural sources) cum 44 7657.42 336926.27
Steel reinforcement for RCC work Thermo mechanically treated bar of grade Fe 550D or more upto plinth and
foundation Kg 5500 91.40 502690.68
5.9 Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass sqm 13
concrete 332.33 4320.30
1) MR 1 Supply of following sizes XLPE insulated (Heavy duty) Aluminium or Copper conductor armoured cables
suitable for working voltage upto and including 1100 Volts complete as required and as per specifications.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size
2 direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as
DSR-2022- Upto 35 sq. mm 40
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size
in the existing RCC/ HUME/ METAL pipe as required.
DSR-2022- Upto 35 sq. mm 35
4) MR 2 Termination of the following sizes of XLPE insulated Aluminium/ Copper conductor cable including providing
terminal lugs,double compression gland , crimping the joints ,providing insulation tape,effecting terminal
connections to the equipment complete as required.
a 2 x 6 sq,mm, Al conductor cable Nos. 350 694.74 2,43,158.05
5) Supply, laying and termination of the following sizes of 650/1100 volts grade PVC insulated copper conductor
wires in existing conduits including end terminations with copper lugs.
AS PER DSR-2022 AS PER MARKET RATE
DSR Rate without
S.NO DESCRIPTION OF ITEM UNIT QTY. Rate without AMOUNT Without GST
GST (RS.) AMOUNT (RS.)
a. DSR-2022- 3 x 2.5 sq.mm. Copper conductor ,PVC insulated PVC sheathed wires RM 500
b. DSR-2022- 2 X 6 sq. mm PVC insulated copper conductor wire along with 1 X 2.5sq.mm PVC insulated copper conductor RM 7,700
6) Supplying and fixing in position of the following sizes of GI conduit buried in ground 600 mm deep including
all accessories complete as required and as per specifications.
a. DSR-2022- 25 mm dia GI conduit RM 500
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC
7 collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling
etc as required.
DSR-2022- 100mm dia 35
DSR-2022- 250mm dia 30
8) MR 3 Supply,fixing and laying of Heavy duty PVC pipes complete buried in floor with joints and other accessories as
12) MR 4 Supply of LED Sports 1500/1600W Floodlight with high-power LED shall be made of Single/Modular housing 188
noncorrosive aluminium die cast PC Modular lens plate with toughened glass to ensure better uniformity of
lighting distribution.,suitable for 15/30/10 degrees. All Lens should be screw fitted on the housing to ensure the
proper mechanical alignment to increase the rigidity of fixing of lens to get the unify photometry distribution.
Designed heat sink for efficient thermal management along with safety chain. The luminaire should be IP66 and
IK07 suitable and detachable separate compartment for driver considering ease of maintenance. Same housing
should be compatible with different beam angle. LED Floodlight luminaire shall have CRI > 70 and CCT >
5700 K (tolerance on CCT: +/- as per ANSI C78:377A), SDCM (Mac Adam Ellipse): < 5. The system Efficacy
of the luminaire shall be typical > 110 Lumen/Watt. The luminaire shall be designed to ensure lumen
depreciation of up to 30% over 50K burning hrs at designed ambient temperature 35 Deg Celsius. The driver
shall have a power factor of >0.95. THD of the driver < 10%, EMI/EMC compliance. The driver shall have Over
Temperature, Under Voltage/Short Circuit, Over Voltage/Open Circuit and Output failure protections, with an
Efficiency of > 90%. Driver can withstand high voltage up to 440V for > 24 Hrs. The floodlight and external
driver (should be potted for better reliability) shall comply to Class-I electrical insulation class. Inbuilt driver
surge protection of minimum 6KV must . Driver is having voltage ripple < 1% (peak to average) and output
current ripple < 5% (peak to average). Driver is having over heating protection circuit (thermal fold back > 75
Deg Celsius) which ensure the safety of luminaire and surrounding. The average lumen maintenance summary
needs to be submitted at the different case temperature (soldering point) at Ts: 55, 85 and 105 Deg Celsius. All
plastic parts, cable used etc. shall be UV protected. Input cable of luminaire should be rubber as per IS 10322
(part 5/section 5). The luminaire should comply with all the required IEC & IS standards. LM79 (C type Gonio
Photometry IES LM 79 -19) & LM80 report must be submitted from a NABL accredited lab. Luminaire and
Driver must have BIS certificate.
13) MR 5 Main Lighting Panel
AS PER DSR-2022 AS PER MARKET RATE
DSR Rate without
S.NO DESCRIPTION OF ITEM UNIT QTY. Rate without AMOUNT Without GST
GST (RS.) AMOUNT (RS.)
1 No. 1000amps 4P ACB(50KA) with Micro Processor release (PRMB) with Class-C transient voltage surge
suppression device suitable for 3 phases as per specifications.
Metering And Indication for each Incomer
1 set of R,Y,B phase indicating lamps
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th
order & %THD) with RS-485 Port.
Sets of 1000/5A, CL-1, 15VA CTs for measuring.
Sets of phase indicating lamp with 2A control MCBs.
1250A TPN Aluminium Bus Bar with colour coded PVC Sleeves
12No. 63amps 4P MCCB
5No. 160amps 4P MCCB
Main Lighting Panel Descrived Above De 1 4,92,193.22 4,92,193.22
17) MR 6 Feeder Piller (Hockey Ground)
Design, manufacture,Supply, Installation, testing and commissioning at works of Double door panel fabricated
with minimum 2mm thick CRCA sheet, Conform to IS Specification, with IP-55 enclosure protection, as per IS-
2137(Revised), floor mounting free standing on a suitable massanory pedestal outdoor type panel,provided
with hinged detachable and lockable outer opening doors with the following incoming/outgong MCCB/ MCBs
mounted therein including making connections/ interconnections, earthing, painting etc. as required.The panel
shall have canopy arrangement on the top.All MCB to be C curve .
a. Feeder Pillar - X
The incoming shall comprise the following :-
1 No 160A FP ATS , 25 KA service breaking capacity with heavy duty solid neutral link alongwith Earth fault
relay and CBCT.
Metering for incoming:
Digital Multifunction meter (MFM-4) with RS-485 communication port for measurement of PF, V, A & Hz ,
equivalent to EM6459, with CT as required.
Phase indicating lamps RYB with 2 Amps SP MCB back up.
200 Amps TPN Aluminium Bus Bars of suitable length Bus bars shall be colour coded and insulated by heat
shrinkable sleaves & clip on shrouds for joints. The current density of Bus bar shall be 0.8 sq.mm./amp.
Outgoing (All MCB shall be suitable for motor duty & with heavy duty detachable solid neutral link ):
ii. 57 nos 25A DP MCB 10 KA breaking capacity controlled by and including providing 40 DP MCCB, 40 A DP
contactor and Timer.
Feeder Pillar - X described as above and all as per specification. Set 4 2,38,423.73 9,53,694.92
a. 1 No. 600amps 4P MCCB(35KA) with Micro Processor release (PRMB) with Class-C transient voltage surge
suppression device suitable for 3 phases as per specifications.
AS PER DSR-2022 AS PER MARKET RATE
DSR Rate without
S.NO DESCRIPTION OF ITEM UNIT QTY. Rate without AMOUNT Without GST
GST (RS.) AMOUNT (RS.)
Metering And Indication for each Incomer
1 set of R,Y,B phase indicating lamps
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th
order & %THD) with RS-485 Port.
Sets of 1000/5A, CL-1, 15VA CTs for measuring.
Sets of phase indicating lamp with 2A control MCBs.
1250A TPN Aluminium Bus Bar with colour coded PVC Sleeves
5No. 160amps 4P MCCB
ii. DG Panel Descrived Above
19)c MR 7 Supply,Installation,Testing and Comssioning of 45meter height GI Pole with suitable 1600w ,47 Light and Nos. 4 3,17,715.25 12,70,861.02
location wind pressure with all installation acessrios.
20) Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry 5
enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ Set 6,332.20 31,661.02
coke and salt as required.
21) Supply and fixing in position the following G.I. tape/wires including providing all fixing accessories and effecting
proper connections.
a. DSR-2022- Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection 350
5.11 with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
b. DSR-2022- Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including RM 600
5.7 connection/ termination with GI thimble etc. as required.
MR 8 DG Set work
Supplying,loading, installation,testing & commissioning of Diesel Generating set having Prime Power Rating of
600 KVA, radiator cooled type, with Acoustic Enclosure with Silent Type silencer, 415 Voltsat 1500RPM,
0.8lagging power factor suitable for 50Hz, 3phase system and as per latest CPCB-II, 600 Ltr in built fuel
tank.The DG Set sshall be suitable for being over loaded upto10% of the rated capacity for 1hour in every 12
hour sand consisting of the followings: The DG set shall be suitable for above 0.85 loading factor with net out
put shall be 600 kVA as per site conditions with Genset governing Class G3 as perI S8528.Silent Diesel
Genset shall be provided with remote monitoring system to monitor the genset operational parameters at
desktop/ smartphones.
4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at
40Degree C, 50%RH & at 1000 MS Land conforming to BS 5514, BS 649, IS 10000, capable of taking 10%
overloading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the
required accessories.
Type: Radiator Cooled
Fuel injection :As per manufactur
AS PER DSR-2022 AS PER MARKET RATE
DSR Rate without
S.NO DESCRIPTION OF ITEM UNIT QTY. Rate without AMOUNT Without GST
GST (RS.) AMOUNT (RS.)
Engine Starting : Battery starting.
Starting position : Universal. Auto/Manual
The Engines shall include:• Flywheel with guard.• Flexible connection.• Bellow / expansion joints• Air Cleaner•
Blower fan• Electronic governor with electronic fuel injection system• Fuel and lube oil filters and pumps• Day
Fuel tank with visual level indicators etc.• Silencer as per latest amendments of MOEF/CPCB • Safety controls•
Instrument panel
•Exhaustpipingtoletouttheexhaustatmandatoryheightabovethecanopyincludingsupportarrangementandinsulation
withcladdinginside the canopy etc.
Synchronousalternatorratedat1010KVA,415voltsat1500RPM,3phase50HZ,ACsupplywith0.8laggingpowerfactor
at40DegreeC,50%RH&at1000MeterMSL.ThealternatorshallbehavingSPDPenclosure,brushless,continuousduty,
selfexcited&self-regulatedthroughsuitableAVRconformingtositeconditionandwithClass-Hinsulation.
Type : Brushless.
Actual Power 600 KVA at 40 deg C.
Frequency : 50 Cycles/sec.
Supply System: 3 phases & neutral
Connection : Star.
Rated rpm. : 1500 RPM
Casing protection : As per IP-23
Insulation : Class H.
Power Factor : 0.8.
Controller:TheDGsetsshouldbesuitableforAutoON/OFForequivalent including providing of Engine control panel.
C. ACCESSORIES:
TheDieselEngineshallbeequippedwithminimumfollowing/asindicatedinthespecifications,devices/accessoriesbuilt
-intypeincluding all standard fittings.
Fuel supply pump with manual venting pump. Set 1 32,50,508.47 32,50,508.47
Turbo charger with air filter (dry/oil bath type) and damper.
Charge air cooler.
Suction fuel filter
Lube oil filter.
Hour meter and RPM indicator.
Battery Starting Mechanism.
Instrument/Indication panel complete with the followings;
a) Starting Switch with key.
b) Lub. Oil Temp. gauge.
c) Lub. Oil Pressure Gauge.
d) Water Temp. gauge.
Control devices for safety and monitoring along with indicators.
Common base/foundation frame.
Anti vibration pads
24VDCStartingsystemcomprisingofstartermotors:Voltageregulatorandarrangementforinitialexcitationcompletewi
thsuitablenos.ofMaintenancefreebatteriesaspermanufacturerstandardsforminimum 6 no. consecutive starts as
required as per specifications.
The cost of initial charge of lubricants, coolant etc.
TheDGsetsshallincludethecostofallaccessories,fittings,protections,instruments,safetycontrols,alarms,indications
etc.complete as per specifications, as required
AS PER DSR-2022 AS PER MARKET RATE
DSR Rate without
S.NO DESCRIPTION OF ITEM UNIT QTY. Rate without AMOUNT Without GST
GST (RS.) AMOUNT (RS.)
SITC of 50 HP monoblock pump with starter, cable connection from nearby feeder and requisite civil work for set 1 1,97,872.88 1,97,872.88
MR 9 water supply at sprinkler irrigation system at Biju Patnaik Hockey stadium complete in all respect as per
direction of engineer in charge
Total of Sub-Head - V carried to summary sheet 42,13,119.45 2,52,26,717.37
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT_Flood Lighting.pdf
Tender Document
GCC2022.pdf
Tender Document
SCCFlood light.pdf
Tender Document
Milestone Hockey.pdf
Tender Document
Technical_Specifications-_Electrical_Work.pdf
Tender Document
Drawings.pdf
Tender Document
LOM hockey.pdf
Tender Document
BOQ Hoceky.pdf
Tender Document
corrigendum-2935-Corrigendum02.pdf
pdf • 0.12 MB
corrigendum-2910-Corrigendum_NIT13.pdf
pdf • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .