Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Qualified. |
| 2 | Accepted-Technical 14 D CHANDI CHARAN GHOSH ROAD KOLKATA 700008 | KOLKATA | WEST BENGAL | 700008 | Accepted-Technical Qualified. |
| 3 | Accepted-Technical | Accepted-Technical Qualified. |
| 4 | Accepted-Technical | Accepted-Technical Qualified. |
| 5 | Accepted-Technical | Accepted-Technical Qualified. |
Tender Value
₹3.9 L
EMD Value
₹7,733
Closing Date
13 Aug 2026, 11:00 amClosed
Assistant Engineer, BNWSD-II, VYBK
The Office of The Assistnt Engineer, Bidhannagar West Sub Division-II, Public Works Directorate, Government of West Bengal, Room No. 123, 1st Floor, Purta Bhavan, DF Block, Sector - I, Salt Lake, Kolkata - 700 091.
Repair and Painting of Rooms and Toilet of Hon ble Minister Chamber at 1st Floor and 5th Floor including replacement of curtains of Joint Administrative Building Department of Planning and Statistics during the year 2026 2027
2026_WBPWD_5017682_6
NIeT-06/AE/BNWSD-II of 2026-2027
Open Tender
CIVIL WORKS
Percentage
15 days
SALT LAKE
Please refer Tender documents.
6 documents required · 6 mandatory
₹7,733
Yes
14 Oct 2026
30 Jul 2026
17 Aug 2026
30 Jul 2026
13 Aug 2026
30 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | (b) Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick) | 139.21 | Sq. M. | - | - |
| 2 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive
Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat. (ii) Solvent based interior grade Acrylic Primer. | 139.21 | % Sq. M. | - | - |
| 3 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats)
(ii) Luxury Quality. | 139.22 | Sq. M. | - | - |
| 4 | Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430/1510 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 4 mm thick High Pressure Steam Cured Non Asbestos pearl designer Fibre Cement Standard Ceiling Board (Density > 1500 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type A Category IV of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In ground floor. a) False Ceiling (with 4mm thick Pearl Designer Fibre Cement Board and E-Grid T-2430/1510). | 29.74 | Sq. M. | - | - |
| 5 | Polyurethane Polishing to woodwork with required colour as approved by Engineer-in-Charge with preparing surface including scaffolding and hire charges of compressor machine including cost of filler and hardener material such as P. U. Sealing, P. U. Top coat (Matt/Glossy), Thinner, Spirit etc. and inclusive of all operation, material and labour complete as per direction of Engineer-in- Charge. | 210.07 | Sq. M. | - | - |
| 6 | Supplying, fitting and fixing shower of approved brand and make. (f) Hand shower (Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar). | 2 | Nos. | - | - |
| 7 | Supplying, fitting and fixing bib cock or stop cock. (d) (ii) Chromium plated concealed Stop Cock heavy duty (Equivalent to Code No. 5083 & Model - Florentine of Jaquar or similar brand). | 3 | Nos. | - | - |
| 8 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.
(ii) 550 mm X 400 mm size. | 1 | Nos. | - | - |
| 9 | Supplying, fitting and fixing pedestal of approved make for wash basin (white). | 1 | Nos. | - | - |
| 10 | Supplying, fitting and fixing pillar cock of approved make. e) (ii) CP Wall Mixture without spout but with provision for connnection to Telephone Shower and exposed pipe for Overhead shower (Equivalent to Code No. 5215 & Model - FLORENTINE of JAQUAR or similar brand). | 1 | Nos. | - | - |
stage.html
html • 0.10 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
2911.pdf
Tender Documents • 1.86 MB
BOQ_5088033.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .