Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹84.4 L+₹10.3 L (13.9%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L2 | Rejected-Finance Not lowest Bidder | |
| 3 | L3₹91.8 L+₹17.7 L (23.9%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTER SARU SECTION ROAD JAMNAGAR 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L3 | Rejected-Finance Not lowest Bidder |
Tender Value
₹75.1 L
EMD Value
₹1.4 L
Closing Date
19 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Jamnagar
CWE (AF) Jamnagar Air Force Station Jamnagar-361003
ADDN / ALTN / IMP TO ATC INFRASTRUCTURE AT AF STN JAMNAGAR
2023_MES_602480_1
81135/E8
Open Tender
Civil Works
Lump-sum
240 days
Jamnagar
Class C and category a (i)
7 documents required · 7 mandatory
₹1,000
GE (AF) No 1 Jamnagar
₹1.4 L
Yes
28 Jul 2023
10 Jun 2023
21 Jul 2023
10 Jun 2023
19 Jul 2023
5 Jul 2023
11 Jun 2023 - 16 Jun 2023
Amount
NOTE: Schedule ‘A’ Part I to IV are under Ser No. 1.00 to 4.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I.
Lump sum price worked out for (SITE CLEARANCE, EXCAVATION AND EARTHWORK) as listed in Sch `A’ Part II
Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch `A’ Part III
Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch `A’ Part IV.
SCHEDULE 'A' PART - V (MISC ITEMS) (Note for items here in after: The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES)
Supply and fixing of Crash/gong bell 9 inches to be fixed on wall connected all as specified and directed
Supply & fix wall mounted fan plastic body AC single phase 230/ 240 V of size 300 mm sweep with louver all as specified and as directed.
Supply and fixng of cable tray size 300mm width 14swg thickness and 50 mm height to be fixed on angle L shape along the wall including all necessary civil work all as specified and as directed.
Supply and fixng of cable tray size 350mm width 14swg thickness and 50 mm height to be fixed over the roof/wall on u shape angle having height of 0.3 meter to be grouted on wall and including pcc and allied work all as specified and as directed
Disconnecting, Shifting and reconnecting of LT cable lying/hanging on wall and fixing inside cable tray all as specified and as directed.
Dismantling of cassette indoor unit of any tonnage and refixing at same location after leak testing , repairing of pipe/conduit ,charging of gas and making effectively functional all as specified and as directed
Supply, install, commissioning and testing of Air Cooled Inverter based split AC unit with cooling functions and suitable to operate at ambient conditions of (-10 to 46 Deg C in cooling Mode). Air conditioner will have following conditions:- (i) Refrigerant - R 410a (ii) EER - min 3.5 w/w (5 star rating as of 2023) (iii) Tonnage - 2.0 (iv) Indoor Noise Level - Not more than 48 Db (v) Filter - (a) Must have PM 2.5 µ Filt (b) Electrostatic dust filter (c) Oxidizer dust filter (vi) Functions of remote : (a) Air directional control (b) Auto Timer (c) Economic sleep mode (d) Auto fan speed (e) Auto swing (f) Temp display (g) Turbo mode All specification will be as per IS-1391 (Part 2) 1992 Room Air Conditioners.
Note:- Following will be inclusive in the above rate:- (a) Piping and cable length upto 15 mtr will be inclusive in item (b) Installation will include fixing the outdoor unit on the platform as per direction of Engineer in Charge. (c) Installation will also include civil work for making hole on the wall and putting the iron sleeve for passing the refrigerant pipe. (d) Testing and commissioning of the Air conditioner to the entire satisfaction of Engineer in Charge. (e) Contractor will provide min warranty of 5 years for compressor from the date of installation. (f) Air conditioner will be tested by the Garrison Engineer for Energy Efficiency and all the functions provision in the Air conditioner. (g) Contractor provide complete free service in warranty period by the company.
Supply, install, commissioning and testing Voltage stabilizer of automatic operation single space naturally air cooled indoor type and designed for following features: (a) capacity:- 5KVA (b) Working Voltage range- 130V-280V AC (c) Salient features:- (i) Intelligent time delay system 3min (ii) Compatible with regular and inverter AC (iii) Wall mounting cabinet design (iv) Low and high voltage cut off (v) Digital display
Dismantling carefully of copper pipe, service wire etc from indoor & outdoor unit and refixing of outdoor unit at another location. Refixing work consist of extension of copper pipe & service wire upto 3m each, refixing on wall with saddles including making good the distubed, PCC work, MS angle work for AC outdoor and servcing, gas charging and making effectively functional all as specified and as directed.
Dismantling carefully of copper pipe, service wire etc from outdoor unit and refixing of outdoor unit at another location. Refixing work consist of extension of copper pipe & service wire upto 2m each, fixing on wall with saddles including making good the distubed, PCC work, MS angle work for AC outdoor and servcing, gas charging and making effectively functional complete all as specified and as directed.
M & L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to underground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: For measurement purpose any punned thicness of sand will be considered.
B/R Misc Work and Parking shed
Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed.
Demolition cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Blank
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion from cement, concrete, brickwork etc and making good disturbed ground, complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Demolition of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, Including removal of debries out side MD land complete.
Cutting holes of superficial area exc 400 Sqcm but n exc 0.10 Sqm into or through stone walls built in cement mortar or cement lime mortar or walls of cement concrete and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required, complete all as specified and as directed.
S&F 25 mm size magnetic catches with Plastic body and striking plate including letting in and fixed complete all as specified and as directed.
Bull nosing by Grinding /Rounding to edges of not exceeding 40mm thick stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
Taking down Aluminium window / ventilators / partition wall of any description and in any position in building and removing form site all as specified and directed.
M&L stainless steel butt hinges medium grade 75 mm long complete all as specified and as directed.
M&L stainless steel handle 100 mm long complete all as specified and as directed.
M&L for prepatration of new plastered wall surface including pilaster/cornices etc and applying two coats of oil bound distemper paint of any tint as approved over one coat of primer applied as per manufacturer's instruction complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with bead exc 1.5 Sqm complete all as specified and as directed.
Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MD land all specified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410 ( grade E-250) quality B, complete all as specified and as directed.
M&L for Cutting channels,grooves or rebates n exc 15 cm girth,and trimming surfaces with or without reinfiorcement, of concrete surfaces and block / stone masonry etc, including filling of PCC as a fillet on sheet, complete all as specified and as directed.
S& F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes for vertical post, purlins and rafter conforming to IS 1161-1979 Grade St. 240 ccomplete all as specified and as directed.
S & F roof trusses (framed), trussed,purlins,crane gantries,rails and fastenings and heavy bracket framing (Beam,tee,angle,channel or flat sections)including distance pieces,cleats etc, complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint on wooden surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of pink primer complete all as specified and as directed.
M & L for preparation of new steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
M&L 25 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in sub base flooring complete all as specified and as directed.
M&L for rendering in CM 1:6, 10mm thick on fair faces of brick work or concrete surfaces and rendering is to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed.
S&F Brass Locks 4 levers, cupboard, grade I, size 50 mm complete all as specified and as directed.
Excavating in Soft/loose soil in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and as directed.(Manual means)
M&L for plastering in 15 mm thick in two coats (10 mm under coat in CM 1:6 plus 5mm finishing coat in CM 1:4) on external concrete or stone surfaces of bldg by using LW+ water proofing chemical of Dr. Fixit or equvalent as per manufacturer's instruction and finishing the surface even and fair. (Water Proofing Chemical shall be measured and paid seperately) complete all as specified and as directed.
Supply only Liquid Water Proofing compound( Model LW+ of Dr Fixit or Eq make as specified). (ISI marked)
M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm /litre and UV resistance as IS 15489:2004, Alkali and fungal resistance, dirt resistnce exterior paint of required shade ( Company depot tinted) with silicon additive @1.43 litre / 10 sqm over and including priming coat of exterior primer appplied @ 0.90 litre/ 10 Sqm over new surface, complete all as specified and as directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, complete all as specified and as directed.
S&F Telescopic channel of size 500 mm ( When Closed) complete all as specified and as directed.
M&L for forming Contraction ( Dummy Joint) 65mm deep x 10 mm wide filled with grade 'A' cpmpound complete all as specified and as directed.
M&L 100 mm thick for Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) as flooring / paving including making chequred impression complete all as specified and as directed.
S&F18/19 mm thick plywood (12 Nos of ply ) grade BWP, type BB fixed width screws to timber frame work or ply wood including 2nd class HW fillets of bullnosed splayed, chamfered or rounded edge ect. exc 3 and n. 6 sqcm complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F 12 mm thick plywood (7 Nos of ply ) grade BWR, type BB fixed width screws to timber frame work or ply wood including 2nd class HW fillets of bullnosed splayed, chamfered or rounded edge ect. exc 3 and n. 6 sqcm complete all as specified and as directed.
S&F Mineral Fiber Acoustical suspended ceiling system with beveled regular edge tiles laid over & including 15mm exposed grid system detail as under :- (a) The tiles should have humidity resistance (RH) of 99% , NRC 0.5, Light reflectance > 87% , Thermal conductivity k=0.052-0.057 w/m K, colour white, fire performance UK class 0/Class 1 (BS 476 pt -6 &7) inmodule size of 600x600x16mm, suitable for green building applicatin, with recycled content of 30%. (b) The tile shall be laid on 38mmx15mm wide T-section flanges colour white having rotary stitching on all T sections i.e the Main Runner, 1200mm & 600mm cross Tees with a web height of 38mm and a load carrying capacity of 14 kgs/sqm & pull out strength of 100 kgs. The T sections have galvanizing of 90 grams per sqm.
(c) Grid system shall comprise main runner spaced at 1200mm centre to center securely fixed to the structural soffit using suspension system as specifications below at 1200mm maximum centre. The first/last suspension system at the end of each main runner should not be grater than 450mm from the adjacent wall, flush fitting 1200 mm long cross tees to be interlocked between main runners at 600mm require independent support, 600x600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200mm cross tees. Perimeter trim to wall angles of size 3000x19x19mm, secured to walls at 450mm maximum centre to centre.
(d) Suspension system shsll consisting of M6 Anchor Fasteners with Vertical Hangers made of Galvanised steel of size 26x26x25x1.2mm, Apre straightened Hanger wire of dia 2.5mm of 1.8m length, and a tensile strength of 344-413 MPa, along with adjustable hook clips of 0.8mm thick, galvanised spring steel for 2.68mm with a minimum pull strength of 110 kg. The adjustable clip also consists of a 3.5mm aquiline wire to be used with the main runner. Make :Armstrong (Tile shall be model name classic Lite & Grid system shall be model Name suprafine XL 15 exposed) or USG/AMF or equivalent of make approved by GE
S&F Decorative laminates of 0.9mm thick type, or mat finish, colour and pattern as approved by GE, complete all as specified and as directed.
S&F 20 to 25 mm thick machine cut, both side polished kota stone slab fixed as in shelves or partition under kitchen platform, fixed with cement mortar 1:4 complete
M&L Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles of size 600X600 mm, in floors etc. laid over and including 15 mm thick screed bed or bedding layer in CM 1:6 set and jointed in neat cement slurry and pointed in epoxy grout of 3 mm thick acomplete all as specified and as directed.
All as per Item No 59.0 above but laying of tiles as in dado/ Skirting over and including backing coat 10 mm thick in cement mortar 1:4, complete all as specified and as directed.
M&L ACP sheet in all colour of approved brand for external/ internal wall cladding at all height and elevation including necessary aluminium composite panel consist of 3 mm thermoplastic core of anti oxidant LDPE sandwiched between two skin of 0.50 mm thick alloy sheet makit of total sheet thickness of 4 mm. the surface shall be finish with PDVF BASE coating on the top side and service coating on the reverse side shall be with polymer paint.the system to be fixed to the brick/stone/masonary/rcc wall / framed styructure with necessary clamps, bracket and anchored fastner fixed over and including base frame fabricated with aluminium square pipe of size 25mm x 20mm with 1 mm thickness in 600mmx600mm size grid including stanless steel screw nut, bolt, washer,cleat, weather silicon sealant for grove filling, backer road etc complete all as per menufacturer instruction, complete all as specified and as directed.
S&F 30mm thick flush shutters, solid core construction with black board core and both faces is covered with decorative face veneer with lipping/ frame to match complete all as specified and as directed.
Supply fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron) partition wall, partly glazed with 5 mm thick tinted glass and partly panlled with 9 mm thick prelaminated MDF board with both side decorative laminatied including rubber bead joining cleat for fixing in position etc all as specified below complete all as specified and directed. (a) Outer member top & verticle section shall of size 101.60 x 44.45 x 2.5 mm ( Section No 20102) (b) Middle member top & verticle section shall of size 101.60 x 44.45 x 2.5 mm ( Section No 20057) (f) Glazing clip for securing glass / panel shall be be of 0.80 mm thick (Section No 19370). Note:-Section No given above are of make Jindal, Contractor may use similar section of other make mention in Appx B
S&F aluminium (powder coated with approved colour) ventilator, partially glazed and partially louvers, outer frame & mullion fabricated with alumimium section of size 82.50mm x 38.00mmx1.5mm thick (Cat No 20036), half portion glazed with 4mm thick frosted glass including rubber beading & glazing clip, half portion louvers of 80mm wide & 4mm thick frosted glass including alumimium louver patti including SS wire gauge of fixing of 0.36mm dia and 1.40 width of aperture with 25x3mm thick aluminium strip with screw to upper half portion of ventilator all fitting & fixture and fixed in position including taking down old ventilator complete
S&F fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron) three track window (two shutter glazed & one shutters wire gauge) with frame, glazed with 4mm thick tinted glass, and wire gauge with stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm including rubber bead joining cleat for fixing in position, concealed type lock for all two shutter, PVC roller etc all as specified below, complete all as specifed. (a) Frame (top & side ) section shall of size 92.00x31.75x1.50mm (Section o 20831). (b) Frame (bottom) section shall of size 92.00x31.75x1.50mm (section No 20832). (c) Top & side members of shutter section shall be of size 18.00x40.00x1.55mm (Section No 20738). (d) Shutter interlock section shall be size 18.00 x 40.00x1.45mm (Section 20737) (e)Bottom members of shutter section shall be size 18x40.00x1.55mm (Section No 20736)
Supply fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron) door shutter with frame, partly glazed with 5 mm thick tinted glass and partly panelled with 9 mm thick prelaminated particle board with both side decorative laminated including rubber bead joining cleat for fixing in position, aluminium door handle 150 mm size, aluminium barrel tower bolt 200 mm size . 01 Door Closer etc all as specified below complete all as specified and directed. (a) Frame (top & side) section shall of size 101.60 x 44.75 x 2.4 mm ( Section No 14021) (b) Vertical Members of shutter Section shall be of size 85.00 x 44.45 x 2.00 mm (Section No 19560) (c) Top Members of shutter Section shall be of size 83.50 x 44.45 x 2.00 mm (Section No 19581) (d) Lock rail (Middle member) of shutter Section shall be of size 150.00 x 44.45 x 3.00 mm (Section No 19596) (e) Bottom Members of shutter Section shall be of size 150.00 x 44.45 x 3.10 mm (Section No 19584) (f) Glazing clip for securing glass of shutters shall be of 0.80 mm thick (Section No 19370). Note:-(i) Section No given above are of make Jindal, Contractor may use similar section of other make mention in Appx B
M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L Plain cement concrete 1:2:4, type B-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
M&L pre-cast cement concrete block masonary, using solid PCC block of mix 1:3:6 ( using 20 mm graded stone aggregate ), thickness of wall exc 10 cm thick, with plain or inter locking joints as directed, setting in CM 1:6 complete all as specified and directed
S&F fully glazed sound proof fixed type window with UPVC (Unplasticised Poly Vinyl Chloride ) outer frame of sectional area 65 mmx58 mm. All outer frames shall be fully reinforced with galvanised steel. Glazing with 12 mm thick coloured toughened double glass (two glass sealed around the edges with an air space between the two to form a single unit). EPDM/ TP gaskets to be used for better sealing and noise reduction. Co extruded beadings to be used for glazing. Locking system shall be Espag (Multi Point) including sliding window with tinted glass shutters in existing opening with fasteners and sealing with silicon sealant as per manufacturer instructions complete all as specified and as directed.
M&L for 2nd class H/Wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed.
JAMNAGAR ELECTRIC AND MACHINERY CO
M/s SK Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .