| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L1 | Accepted-AOC AOC | |
| 2 | L2₹36.9 L+₹4.7 L (14.5%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹37.0 L+₹4.8 L (14.9%)Rejected-Finance A 3 13 SIMANDHAR ENCLAVE NEAR PAVAPURI BUS STOP GHATLODIYA AHMEDABAD GUJARAT 380061 | AHMADABAD | GUJARAT | 380061 | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹39.0 L+₹6.8 L (21.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 5 | L5₹45.6 L+₹13.3 L (41.4%)Rejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L5 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹49.7 L
EMD Value
₹99,440
Closing Date
2 Apr 2025, 6:00 pmClosed
GE (AF) Chiloda
GE (AF) Chiloda, LekawadaPatia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICTION AND EXTERNAL WATER SUPPLY SERVICES INSTALLED AT SECTOR-09 GANDHINAGAR AND COMN FLT AHMEDABAD AND REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION FITTING AND FIXTURE INSTALLED AT SECTOR-25 AND 27 OF
2025_MES_700601_1
8247/25-26/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GANDHINAGAR AND AHMEDABAD
AS PER NOTICE OF TENDER
7 documents required · 7 mandatory
₹500
GE (AF) Chiloda
₹99,440
Yes
13 Jun 2025
7 Mar 2025
4 Apr 2025
7 Mar 2025
2 Apr 2025
21 Mar 2025
7 Mar 2025 - 20 Mar 2025
Amount
Taking down carefully copper/ aluminum point wiring (Light, fan, socket, power and Bell) including fixture and fittings such as switches, sockets, ceiling roses, lamp, holder , regulators, sockets light fittings etc , removing material to store for keeping in safe custody or for taking credit , and making good disturbed surface of walls, floors, etc complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm single core PVC insulated unsheathed multi stranded copper conductor FRLS cable 1100V grade drawn through and incl PVC casing in capping /conduit with accessories like bends tees, junction boxes etc fixed recessed in wall or ceiling etc including 1.5 Sqmm single core PVC insulated but unsheathed multistrandard copper conductor FRLS cable 1100V grade as earth continuity wire incl sunken type pressed steel terminal boxes of size with 3mm thick bakelite steel white/coloured top cover for :-
(a) One light or one fan or one bell point controlled by one switch complete all as specified and directed.
(c) One 3 pin socket out let 5 Amps on the independent board complete all as specified and directed.
(d) One 3 Pin socket out let 5 Amps on the same board complete all as specified and directed.
(e) One bell point controlled by one switch complete all as specified and directed.
All as per item No. 02 here in before above but with cable of size 2.5 Sqmm PVC insulated on independent board for power plug 15 Amps.
S&F in repair switch piano type 230 volts, 5 Amps, single pole complete all as specified and directed.
S&F in repair Socket out let 2 in 1, 3 pin, 5 Amps flush type 230 volts complete all as specified and directed.
S&F in repair switch socket combination (Box type) universal 2 in 1, 6 pin, 5 and 15 Amps flush type complete all as specified and directed.
S&F in repair switch socket combination (Box type) universal 2 in 1, 3 pin, 5 Amps flush type complete all as specified and directed.
S&F in repair bell push 5 Amps flush type complete all as specified and directed.
S&F in repair Bell Buzzer, Ding dong bell AC 230V complete all as specified and directed.
S&F in repair ceiling rose 3 terminal/ poly carbonate, isolated body complete all as specified and directed.
S&F in repair Lamp holder, insulated body with back plate for battern fitting complete all as specified and directed.
S&F in repair 3 pin plug top 6A, 240 V complete all as specified and directed.
S&F in repair 3 pin plug top 16A, 240 V complete all as specified and directed.
S&F in repair Modular switch one way 6/10A, 1 Module, complete all as specified and directed.
S&F in repair Modular switch one way 16/20A, 1 Module, complete all as specified and directed.
S&F in repair Modular bell push 6A, 1 Module, complete all as specified and directed.
S&F in repair Modular socket 6/10A-2/3 pin combined 2 Module complete all as specified and directed.
S&F in repair Modular socket 16/20A-2/3 pin combined 2 Module complete all as specified and directed.
S&F in repair Modular Fan Regulator, 120W, 2 module complete all as specified and directed.
S&F in repair white cover plate with frame, 1 module complete all as specified and directed.
S&F in repair white cover plate with frame, 2 module complete all as specified and directed.
S&F in repair white cover plate with frame, 3 module complete all as specified and directed.
S&F in repair white cover plate with frame, 4 module complete all as specified and directed.
S&F in repair white cover plate with frame, 6 module complete all as specified and directed.
S&F in repair white cover plate with frame, 8 module complete all as specified and directed.
S&F in repair Modular metal flush box, 3 Module complete all as specified and directed.
S&F in repair Modular metal flush box, 4 Module complete all as specified and directed.
S&F in repair Modular metal flush box, 6 Module complete all as specified and directed.
S&F in repair Modular switch socket combination (Box type) 16A, 6 pin 3 Module complete all as specified and directed.
M&L in repair for Sub main wiring complete with two run of 6 Sqmm single core, PVC insulated but unsheathed, multistranded copper conductor FRLS 1100 Volts grade cable drawn through in and including non metallic, rigid, PVC heavy duty surface conduit/casing capping (ISI marked) with wall thickness not less than 1.8mm complete with all accessories like bends, tees, junction boxes fixed on wall, ceiling and including sunken type pressed steel terminal boxes with 3mm thick bakelite white/coloured (as approved) top cover including 6 Sqmm single core PVC insulated but unsheathed multistandard copper conductor FRLS 1100 Volts grade cable as earth continuity wire and connected to earth dolly complete all as specified and directed. Note :- Two run of 6 Sqmm cable incl one run of earth wire and PVC conduit and its accessories shall be measured and paid as one length.
M&L in repair to replacement of sub main wiring complete with PVC insulated cable of single core 4.0 Sq mm (FRLS) 1100 volts grade with multi stranded copper conductor for drawn through and including PVC casing -capping with accessories incl 4.0 Sqmm unsheathed multi stranded copper conductor as on earth wire complete all as specified and directed. Note :- Two runs of single core cable with one run of earth continuity cable including PVC casing -capping and its accessories will be measured and paid as one unit
M&L in repair to replacement of sub main wiring complete with PVC insulated cable of single core 2.5 Sq mm (FRLS) 1100 volts grade with multi stranded copper conductor for drawn through and including PVC casing -capping with accessories incl 2.5 Sqmm unsheathed multi stranded copper conductor as on earth wire complete all as specified and directed. Note :- Two runs of single core cable with one run of earth continuity cable including PVC casing -capping and its accessories will be measured and paid as one unit
S & F in replacement of for Rigid non-metallic PVC conduit/ PVC casing caping inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable sheet metal enclosure and Supply and fixing sheet metal enclosure, single phase, double door DB, flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links ( without MCB's) 4 ways TPN complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair sheet metal enclosure, single phase, double door DB, flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links ( without MCB's) 12 ways SPN complete all as directed by Engineer-in-Charge.
All as per item No. 35 here in before above but 8 way.
All as per item No. 35 here in before above but 4 way.
Supply and fixing in repair factory made single pole and neutral sheet metal enclosure with a two Pin Socket plug and socket with one single pole MCB 240 Volts, 20 Amps, capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB, TPN 240 volts, 40/63 Amps capacity 10 KA C curve complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB, TPN 240 volts, 16/32 Amps capacity 10 KA C curve complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB, SPN 240 volts, 16 to 32 Amps capacity 10 KA C curve complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB, SPN 240 volts, 5-32 Amps capacity 10 KA C curve complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB, single pole 240 volts capacity 5 Amps to 32 Amps current rating, 10KA breaking capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repair blanking plate any size complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB TP 25/63 Amps 415 volts 10 KA C curve 50 Hz including testing complete all as specified and directed.
S&F in repair for LED tube light fittings 1x10 Watts, 230 volts 2 feet length, surface and wall mounted LED type and including connection up with twin core twisted flexible copper conductior cable of size 1.5 sqmm complete all as specified and directed.
S&F in repair for LED tube light fittings 1x20 Watts, 230 volts surface and wall mounted LED type use and throw type and including connection up with twin core twisted flexible copper conductior cable of size 1.5 sqmm complete all as specified and directed.
SS&F in repair 35/36 W LED 600x600mm size new generation, aesthetically designed ultra modern surface mounting luminaire with high brightness SMD LED as light source, suitable Armstrong/Grid ceiling complete with separate electronic driver complete all as specified and directed.
SS&F in repair new generation, IP-65, energy saving, long life aesthetically designed aluminium landscape luminaire for diffuser lighting with high power LED bollard lights 8/9W including fittings and all connection complete all as specified and directed.
SS&F in repair flame proof LED light in hanger, well glass fitting wall/ surface mounted highbay type light with IP 66 protection of capacity 100 Watt complete all as specified. Note: Quoted rate to be included of required T&P for fixing/ repair of light in hanger.
S&F in repair recess mounted circular LED slim fit low profile down lighter of capacity 6 watt with all connection complete all as specified and directed.
S&F in repair recess/ surface mounted 15 W LED slim compact aluminium die cast LED panel round shaped downlighter low ceiling height Ecco light with driver and all connection complete all as specified and directed.
S&F in repair energy saving IP 65/66 flood light luminaire 120 watt with high power LED as light source complete all as specified and directed.
S&F in repair energy saving IP 65/66 flood light luminaire 100 watt with high power LED as light source complete all as specified and directed.
S&F in repair energy saving IP 65/66 flood light luminaire 70 watt with high power LED as light source complete all as specified and directed.
S&F in repair Ruby (clear) IP-65 40 Watts Post Top,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete all as specified and directed.
S&F in repair LED IP-65 35 Watts building security light, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution alongwith iron bracket to be fixed on wall complete all as specified and directed.
S&F in repair bulb retrofit type 15 watt LED bulb minimum lumens 900, suitable for 180 volt to 280 volt complete all as specified and directed.
Taking down ceiling fan/cabin fan/exhaust fans/ wall bracket fans and dismantling fan blade, dismantling electric connection, removing capacitor, checking of bearings/bushes, cleaning the fan blades with clear water, scrapping the fan blades, placing the bearing, bush, capacitor and painting two coat of synthetic enamel paint incl filling of cavities (capacitor, twin core, flexible cable will be paid under relevant items) reassembling the fan complete after greasing, oiling, testing the same & making the fan serviceable of any sweep and re-hanging and connecting up to the ceiling rose complete all as specified and directed.
All as per item No 59 here in before above, but for exhaust fan 300/380/450mm sweep, any type.
Re-winding of ceiling fan motor of any type and size including removing old burnt wire copper wire as per existing gauge & insulated paper, varnishing including cleaning/greasing complete all as specified and directed. Note:- Taking down & refixing of ceiling fan for winding, painting, replacement of bearing, bush, capacitor and alike will be measured & paid separately
Rewinding only of exhaust fan with required guage super enameled wire including varnishing, insulation, taping complete of up to 450mm sweep.
Supply and fix in repair/replacement exhaust fan of size 250/300 mm sweep silint type in PVC body as required at site complete all as specified and directed by Engr-in-charge.
Supply and fix in repair/replacement wall fan of size 400/450 mm sweep in PVC body as required at site complete all as specified and directed by Engr-in-charge.
S&F in repair capacitor for fan 2.5 MFD complete all as specified and directed.
S&F in repair electronic dimmers, 450W, 250V flush type on the existing phenolic laminated sheet complete all as specified and directed.
S&F in repair MCCB 4 pole, 415V, 100 Amps with breaking capacity 16 KA with including IP 65 sheet metal encloser complete all as specified and directed.
S&F in repair MCCB 4 pole, 415V, 16-63 Amps with breaking capacity 16 KA complete all as specified and directed.
S&F in repair Thermostat of water heater for 25/50 Ltrs capacity AC 230V complete all as specified and directed. Make:- Theta/Bajaj/Danfoss or equivalent as approved by GE.
S&F in repair Water heater heating element for 25/50 Ltrs capacity 1.5 KW/2.0KW/2.5KW/3KW complete all as specified and directed.
S&F in repair flexible hot water pipe of length not less than 60 cm with washer for hot and cold water for geyser connection complete all as specified and directed.
M&L for dismantling electric/water connection and taking down of storage type water heater up to 25 Ltr, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and refixing in situ, complete all as specified and directed by Engr-in-charge. Note :- worn out parts shall be measured and paid separately.
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for foundation of pole and laying of UG cable and getting out in any type of soil complete all as specified and directed.
Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting piont complete all as specified and directed.
Returning filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Taking up or down from trenches/wall/floor/ceiling, steel tubing and connections, including for re-fixing or removing complete all as specified and directed of the following sizes :-
80 mm bore dia
40 mm bore dia
25 mm bore dia
20 mm bore dia
Supply and laying GI tubing medium grade including GI fittings like sockets, elbows, bends, Tees, unions, short pieces etc. laid in trench complete all as specified and as directed of the following sizes :-
80 mm bore dia
40 mm bore dia
25 mm bore dia
20 mm bore dia
Supply and laying UPVC tubing medium grade including UPVC fittings like sockets, elbows, bends, Tees, unions, short pieces etc. laid in trench complete all as specified and as directed of the following sizes :-
40 mm bore dia
25 mm bore dia
20 mm bore dia
S&F in repair gun metal gate/globe valve heavy duty (ISI marked) with iron wheel head screwed both ends for iron pipe for the following bore of pipe including testing complete all as specified and directed.
20mm dia
25mm dia
40mm dia
M&L for cleaning of UG sump upto 50,000 gallons by removing sludge/sand/dirt by means of Manual/by sludge removing pump, cleaning the sump with bleaching powder, drying and applying one coat of lime wash internally after washing with sodium hypochlorite solution complete all as specified and directed by Engr-in- Charge. Note:- Date of Cleaning should be marked on sump with suitable stencil.
S&F in repair to replacement of sluice valve of 100mm bore class PN-1 type duly ISI marked with iron wheel and head non raising spindle stainless steel confirming to IS 14846 flanged ends including rubber joints & jointing material complete all as required at site.
All as per item No. 81 here in before but 80 mm dia.
S&F in repair to replacement of Gun metal foot valve 80/100mm size with all accessary complete all as specified and directed.
M&L Construction of 3mm thick MS Sheet cover fixed on 40mmx40mmx6mm thick angle iron frame embedded in PCC coping with locking arrangement and mild steel surface with two coats of red oxide primer etc complete all as specified and directed.
M&L for preparation of old painted surface of size 80/100 mm dia iron pipe and applying one coat of synthetic enamel paint complete all as specified and directed.
Dismantling, cleaning and over hauling centrifugal mono block pump set of the following capacities including rewinding of motor with appropriate super enameled copper wire of existing gauge, replacement of bearing including all connection and testing complete for following capacities :-
(a) 0.5 to 0.75 HP
(b) 1 HP/2HP
M&L to repair in replacement of electric driven motor (mono block) 0.5 HP capacity up to 15.00 meter head single phase 230 V including necessary connection complete with suction/ delivery pipe of 15mm x 15mm bore complete all as specified and directed.
All as per item No. 87 here in before but 1 HP.
Dismantling and repair of centrifugal pump set of 20 HP 42 Mtr head and opening & replacement of following items incl transporting of pump set to work shop all as directed:- 1. Replacement of CI impeller as per existing size. 2. Replacement of EN-8 pump shaft complete with check put key. 3. Replacement of type C-40 pump casing bottom. 4. Replacement of gland packing plate. 5. Replacement of bearing housing CI complete. 6. Replacement of ball bearing Nos 5309. 7. Replacement of planter ring. 8. Replacement of liquid deflector. 9. Replacement of shaft sleeve SS 410. 10. Replacement of set of key. 11. Replacement of lock washer for support foot. 12. Replacement of lock washer for impeller foot. 13. Replacement of grease nipple. 14 .Replacement of oil level sight glass. 15. Replacement of oil seal. 16. Replacement of gasket set. 17. Replacement of plug set. 18. Replacement of fasteners. Assembling of pump set complete and fixing in foundation and connecting with motor coupling and testing on full load complete all as specified and directed by Engr-in-charge
S&F in repair PVC insulated insheathed multi stranded copper conductor three core flexible type of capacity 2.5 sq mm FRLS cable complete all as specified and directed.
S&F in repair PVC insulated insheathed multi stranded copper conductor three core flexible type of capacity 1.5 sq mm FRLS cable complete all as specified and directed.
S&F in repair of motor starter panel incl replacement of power contactor, timer, wiring and connected accessories as present at site suiable for LT Panel removing the old one and fix serviceable as existing and testing complete all as specified and directed.
M&L for dismentaling and step opening to complete centrifugal motor of cap 20 HP and segrigated all serviceable parts and kept at site for reuse including rewinding with supper enamled wire of suitable gauge complete, and replaceing bushes, bearing check nut, and other required parts and barnishing the same incl painting of motor , making serviceable to the motor complete and servicing, cleaning, greasing, overhauling, re-alingment with lock, key, nut, bolts, washers and reassembling the same with centrifugal pump after testing complete and all as directed by engineer-in-charge. Note :- The contractor will be responsible for maintaining the centrifugal pump in serviceable state for the entire contract period. Since the job involves major overhauling,no additional payment will be made to the contractor if servicing is required more than once.
All as per item No 93 here in before but of size 15 HP motor .
All as per item No 93 here in before but of size 7.5 HP motor .
M&L for preparation of old painted surface of centrifugal pump set of capacity 15/20 HP and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L in repair/ jointing of water Leakge in pipe line of size upto 100 mm dia detect the leakage in line with manual digging including removing old rusted line make necessary connection to new pipes close the leakage and return fill the soil in trenches complete. Note: Pipe/Tubing required will be paid under relevent itmes.
M&L in repair to submersible pumping set and motor capacity 25 to 30 HP, 440V ,3 Phase discharged 510 LPM at 123 Metre head consisting of following:- Opening of submersible motor and cutting to burnt winding and cleaning to slots by cleaning and repair to damage starter etc, rewinding to submersible motor with suitable size of superior quality copper winding wire insulating materials all as directed by Engineer in charge, Replacement of thrust bearing – 01 No, Replacement of bush – 02 Nos, Re-assembling and transporting to Pump House, lowering pump and testing complete. Dismantling of submersible pump set all as directed and replacement of the following items- (i) Replacement of neck ring – 05 Nos, Replacement of brass bushes– 05 Nos, Replacement of shaft bush- 02 Nos, Replacement of impeller -05 Nos. Note: The contractor will be responsible for maintaining the submersible pump in serviceable state for the entire contract period. Since the job involves major overhauling, no additional payment will be made to the contractor if servicing is required more than once.
All as per Item No 98 here in before but 5 Hp to 15 Hp submersible / monoblock pump and consisting of following.
All as per Item No 98 here in before but 20 HP and consisting of following.
M&L for dismantling of centrifugal pump set 30 HP at 42 Mtr head opening & replacement of following items including transporting of pump set to work shop all as directed. (a) Replacement of CI impeller as per existing size. (b) Replacement of EN-8 pump shaft complete with check put key. (c) Replacement of type C-40 pump casing bottom. (d) Replacement of gland packing plate. (e) Replacement of bearing housing CI complete. (f) Replacement of ball bearing 5309. (g) Replacement of planter ring. (h) Replacement of liquid deflector. (i) Replacement of shaft sleeve SS 410. (j) Replacement of set of key. (k) Replacement of lock washer for support foot. (l) Replacement of lock washer for impeller foot. (m) Replacement of grease nipple. (n) Replacement of oil level sight glass. (o) Replacement of oil seal. (p) Replacement of gas kit set. (q) Replacement of plug set. (r) Replacement of fasteners. (s) Assembling of pump set complete and fixing in foundation and connecting with motor coupling and testing on full load complete all as specified and directed by Engr-in-charge.
M&L for dismentaling and step opening to complete centrifugal motor of cap 30 HP and segrigated all serviceable parts and kept at site for resue including rewinding with supper enamled wire of suitable gauge complete , and replaceing bushes, bearing check nut, and other required parts and barnishing the same incl painting of motor , making serviceable to the motor complete and servicing, cleaning, greasing, overhauling, re-alingment with lock, key, nut, bolts, washers and reassembling the same with centrifugal pump after testing complete and all as directed by engineer-in-charge. Note: The contractor will be responsible for maintaining the centrifugal pump in serviceable state for the entire contract period. Since the job involves major overhauling, no additional payment will be made to the contractor if servicing is required more than once.
Supply Only calcium Hypo chloride granel 65% to 70% chlorite granule for water purification in Original sealed container with test certificate complete all as specified and directed.
M&L for Lowering & lifting of existing pump set from borewell and repaired pump set with taking out carefully of 18 Nos. column pipe of 80/150 mm size each length of 3 mtr with flange joints repairing/ welding all as required at site to column pipe and including cable proper fixing with pump set and column pipe and making connection with existing starter all as required at site and as directed by Engr-in-charge. Note :- Cost of flange type with jointing material like nut-bolts, gasket sheet etc. shall be included in item rate quoted.
S&F in repairs flat 3 core copper conductor PVC insulated & PVC sheathed cable 1100 Volts grade of size 10 Sqmm water proof and including 40 mm dia PVC conduit fixed to wall/ in duct laid in floor/trench etc complete all as specified and directed.
M&L for taking down of old panel and repair in replacement of same with factory made in door type panel made out of 2mm thick CRCA sheet powder coated suitable for up to 30 HP submersible pump embedded on required size brick masonry platform comprising of following:- (a) Star delta starter for 30HP- 01 No (b) MCCB TP 63Amp, 25KA – 01 No (c) Isolator TPN 32Amps – 01 No (d) Amps meter with CT-01 No (e) Volt meter 0-500V- 01 No (f) Single phase preventer – 01 No (g) Indicating lamp – 1 Set (h) Copper bus bar 200 Amp – 1 No
M&L for Collection of water sample from borewell/Sump & getting then tested from Govt laboratry & furnishing test report, indicating chemical, & bactrological analysis including presrence of floride, TDS, LEAD contents if any complete all as specified and directed by Engr-in-charge.
S&F in repairs MS column pipe 100 mm dia medium grade (heavy duty) flanged type incl necessary fixing MS nut, bolt, washer & gaskets' etc incl groove for cable entry system of 3 mtr in length complete all as specified and directed.
Servicing, repair and testing of fire alarm panel (non comprehensive maintenance) having appx 10 devices which includes quarterly visit and emergency callout of make honeywell. Note :- (a) Check all connection of control panel. (b) Check correct unobstructed setting of detectors and call points. (c) Test detector and call point in each zone. (d) Test alarm sounders. (e) Correct fuse rating, Secure battey terminal. (f) Cleaning of control Panel. (g) From test 2.1 Check alarm zone/ address/ location reported, stimulate fault isolation in each zone. (h) Contractor will responsible to keep panel in serviceable condition If any dameged electrical, mechanical, electronic part/ element noticed while repair/ Servicing it will be changed in the contract period without any extra cost.
S&F in repair battery 12 Volt, 7.0 Ah rechargeble VRLA type complete all as specified and directed.
S&F in repair hooter cum flasher for fire alarm panel as per existing sample complete all as specified and directed.
S&F in repair smock detector for fire alarm panel as per existing sample complete all as specified and directed.
S&F in repair MCP resettable for fire alarm panel as per existing sample complete all as specified and directed.
S&F in replacement of fire alarm panel of existing make and capacity or equivalent as approved by GE complete all as specified and directed.
Material and labour for point wiring for one light point or one fan point or one bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core,FRLS PVC insulated & unsheathed cable, 1100 volts grade drawn through concealed PVC conduit and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLS PVC insulated & unsheathed cable as in earth wire connected to common earth dolly factory made GI sheet sunken box with cover plate complete all as specified and directed.
All as per Serial item No. 115 here-in-before but point wiring for 3/5 pin switch socket outlet combination, 5 amps on same board.
All as per Serial item No. 115 here-in-before but point wiring for 3/5 pin switch socket outlet combination, 5 amps on independent board.
All as per Serial item No. 115 here-in-before but point wiring for one 6 pin switch socket outlet combination, 5/15 amps (independent) with using 2.5 sq.mm (nominal area) copper PVC insulated unsheathed stranded copper conductor as continuous earth wire on independent board for one socket outlet 3 pin 15 amps
S & F in replacement switch piano type 230 volts, 15 Amps, single pole complete all as specified and directed.
S & F in replacement Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified and directed.
S & F in replacement only fan regulator step type suitable for ceiling fans, prewired 230 volts AC 50Hz supply 60Watt complete all as specified and directed.
Supply & Fixing in replacement industrial type sheet metal enclosures with a two pin and earth plug and socket, 250 volts with including 20 Amp SP MCB complete all as specified and directed.
S & F for PVC insulated aluminium stranded conductor of size 10.0 sq.mm twin core flat or circular cable 1100 volt grade, heavy duty cable, served with inner sheathed cable complete all as specified and directed.
Supply, fixing, connecting and testing sheet metal enclosures double door type for using MCBs suitable for single pole and neutral, 16 way with having copper bus bars suitable for 200 amps rating including taking down old unserviceable one complete all as specified and directed.
S & F in replacement LED light fitting 1x9W/1X10W bulkhead luminaires including LED light holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in replacement for Decorative, wall mounting, brushed nickel finish fixture with dual Opal Glass diffuser suitable for LED lamp B22 Base complete all as specified and directed.
S&F in replacement intrigal decorative LED bollard with opal acrylic 9 watt LED 3000K with IP 65 protection as per existing sample complete all as specified and directed.
S&F in replacement decorative coloured flood light, suitable for focasing of tree / buildings of capacity 100 watt, 240 volt, 50 HZ complete all as specified and directed by Engr -In-Charge.
S&F in replacement Post top lanterned 20 watt suitable for 180 volt to 280 volt complete all as specified and directed by Engr-In-Charge.
S&F in replacement LED strip suitable for decorative 18 meter LED rope light , water proof, RWG colour with adaptor , suitable for 180 volt to 280 volt complete all as specified and directed by Engr-In-Charge.
Supply & Fixing in repair Ultra bright polycarbonate LED retrofit tube light rod 18 watt with very high efficacy complete all as specified and directed.
S & F in replacement for High light intensity empowered color changing & monochromatic LED under water fountain light with polarized light design & intelligent logarithmic control technology as per existing sample complete all as specified and directed.
S&F in replacement water proof led power supply controler (SMPS) of capacity 500 watt, input 230 volt and out voltage DC 12 V, +- 5%, suitable for control fountain LED lights as per sample complete all as specified and directed.
Supply & fixing in replacement LED bulb retrofit type 9/10 watt, efficacy 100 Lm/W suitable for 180 volt to 280 volt complete all as specified and directed.
Supply & fixing in replacement LED bulb retrofit type 0.5 watt, Red/ Green colour suitable for 180 volt to 280 volt complete all as specified and directed.
Supply & fixing in replacement of Decorative post top lantern doom made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 base as per existing sample complete all as specified and directed.
S & F in replacement of multi stranded copper conductor cable of size 1.0 sq.mm, 3 core including taking down of existing unserviceable one complete all as specified and directed.
S & F light fitting 1x30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
M & L for chemical earthing complete copper earth plate of copper earth plate of 900 x 600 x 5 mm buried directly in ground) Earth pit not less than 4.0 meter below the ground level with top edge of the earth plate at a depth not less than 3.25 meter below ground level connected to cooper earth strip 32 x 6 mm upto 7.5 meter long by means of copper nuts, bolts, check nuts & washer etc with including necessary earth work and common salt and charcoal dust in alternative layers of 15 cm up to 90cm above the top of copper plate ( approximate quantity of salt 500kg, charcol dust 1000kg, magnesium sulphate150 Kg,) and making Pre- cast RCC earth pit with cover including dismantling/taking out of old unserviceable earthing of any position complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as per shown in electrical plate No. 5 of MES Schedule Part-I with connected to earth test point main switch board with including necessary earth work and Pre- cast RCC earth pit with cover and including dismantling/taking out of old unserviceable earthing of any position complete all as specified and directed.
All as per Serial item No. 140 here-in-before but using galvanised iron strip 32×6mm as earthing lead.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4.0 mm dia galvanised iron or steel wire complete all as specified and directed.
All as per Serial item No. 142 here-in-before but using 20x3mm copper strip
S & F in replacement of GI pipe 40 mm dia light grade for earth strip protection complete all as specified and directed.
M & L for replacement of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
M & L for colour coding of earthing pit cover with the following colour Red for Chemical earthing and yellow for conventional earth pit complete all as specified and directed.
M&L for recharging of chemical earth pit by using liquid chemical earthing solution (not less than 10 Kg) and mixing with water and filling into the chemical earth pit to achieve result earth value less than 1 Ohm, complete all as specified and directed.
M&L for recharging of conventional earth pit by using salt (not less than 20 Kg) and mixing with water and filling into the earth pit to achieve result earth value less than 5 Ohm, complete all as specified and directed.
S & F Pre- cast RCC earth pit with cover incl watering funel and wire mesh as per sample and including dismantling/taking out of old unserviceable of any position complete all as specified and directed.
Re-winding of desert cooler blower motor 1275 RPM of any capacity including removing old burnt wire copper wire as per existing gauge & insulated paper, varnishing including cleaning/greasing complete all as specified and directed. Note:- Taking down & refixing of fan after winding, painting and replacement of bearing, bush, capacitor etc. will be measured & paid separately.
All as per Serial item No. 150 here-in-before but for wall fan motor of 400mm sweep any type.
All as per Serial item No. 150 here-in-before but for pedestal or air circulator fan motor of any sweep.
Supply & fixing in replacement of Ball bearing suitable size to the existing ceiling fan, Exaust fan, wall fan of any type complete all as specified and as directed.
Supply & fixing in replacement of Exaust fan capacitor 3.25/ 4.0 MFD capacity complete all as specified and as directed.
Supply & fixing in replacement of hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable to ceiling fans down rods complete all as specified and as directed.
M& L for Painting of old ceiling fans/Exhaust fan of any size complete, in situ with synthetic enamel paint by praying including filling cavities with filler, one coat after cleaning all dust etc. writing the fan numbers/MES numbers etc with black paints complete all as specified and as directed.
S & F in replacement wall/exhaust fan blade any sweep as per existing sample complete all as specified and as directed.
S & F in replacement ceiling fan blade any sweep as per existing sample complete all as specified and as directed.
Supply & fixing in repair ventilation fan PVC 200/300 mm sweep complete all as specified and as directed.
Supply & fixing in replacement MS 600mm long ceiling fan down rod 20mm dia as per sample complete all as specified and as directed.
Note : For item No 1 to 160 1. Quoted rate should be included of labour charge contractor has to deploy minimum two electrician on routine basis for day to day internal electric complaint, one plumber for water supply complaint. 2. complaints of day to day internal electrification and water supply should be attended and rectified within 24 hr otherwise a penalty of rupees 500.00 Rs per day per complaint will be recoverd from the contracter.
ALBA AC AND REF SERVICES (BID ID -3270871)
JYOT ENTERPRIES (BID ID -3275647)
Dighard Electricals (BID ID -3271098)
Abhishek Enterprises (BID ID -3275423)
Electricals India (BID ID -3275548)
Shree Builders (BID ID -3273920)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .