| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC JANAKI NIVAS BEHIND CHOVVA TEMPLE CHOVVA PO KANNUR KERALA 670006 | KANNUR | KANNUR | KERALA | 670006 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹14.5 L+₹69,012 (5.01%)Rejected-AOC | L2 | Rejected-AOC Not being lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
1 Apr 2023, 6:00 pmClosed
CWE WELLINGTON
Headquarters Commander Works Engineers Wellington, Barracks Post The Nilgiris PIN 643 231
SPECIAL REPAIRS TO BLDG NO WL-09/08, WL-09/09 AND WL- 09/10 OF DSC RECORDS UNDER AGE (I) CANNANORE
2023_MES_581100_1
84701/E8
Open Tender
Civil Works
Item Rate
120 days
CANNANORE
For MES Enlisted Contractors - Class E, Category a (i) For other contractors Meeting Enlistment Criteria of MES for Class E, Category a (i)
7 documents required · 7 mandatory
₹500
AGE (I) CANNANORE
₹30,000
11 May 2023
15 Feb 2023
3 Apr 2023
15 Feb 2023
1 Apr 2023
13 Mar 2023
15 Feb 2023 - 22 Feb 2023
Amount
Dismantling existing old roof treatment of any description, type and in any position including removal of old tiles, screed, felt, etc complete all as specified and directed.
M&L Cement concrete 1:2:4 type B-0,using 12.5mm graded aggregate 25mm thickness including waterproofing compound as per manufacturer's instructions for padding concrete to achieve required slope and thickness over roof/chajja finished even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound can be measured and paid seperately.
Supply only Integral waterproofing compound complete all as specified and directed.
M&L Providing 4mm thick APP modified water proofing membrane, weighing not less than 4kg/sqm reinforced with non woven polyster matt (weighing not less than 160gms/sqm) having softening point not less than 140 degree centigrade, longitudinal tensile strength not less than 800N/sqcm tearing strength of 180 Nm, and laying by torch application including minimum 10cm side overlap and 15 cm end lap over applying bitumen based primer @ 0.2 kg/sqm and applying solar reflective bituminous aluminium paint @100gms/sqm complete all as specified and directed.
Disconnecting existing tanks setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required re-connecting and re-fixing in position complete all as specified and directed.
Taking down GI tubing and connections and removing to store of pipe 15mm bore complete all as specified and directed.
Taking down GI tubing and connections and removing to store of pipe 20mm bore complete all as specified and directed.
S&F Unplasticised PVC pipes 15mm bore of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors complete all as specified and directed.
S&F Unplasticised PVC pipes 20mm bore of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors complete all as specified and directed.
S&F Stop valves, 20mm bore cast copper alloy, screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Demolition of brick work or concrete/ stone masonry wall built in cement mortar complete all as specified and directed.
M&L Walling of laterite stone walls uncoursed, well bonded bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed.
Demolition of cement concrete (reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) reinforcement cut as required to facilitate demolition complete all as specified and directed
M&L RCC 1:1.5:3 type B1 using 20mm graded stone aggregate in slabs, shelves complete all as specified and directed.
M&L Formwork to soffits of slab rough finished surfaces of concrete complete all as specified and directed.
M&L Formwork to edges of concrete flats,floor and roofs n exc 20 cm wide and similar work exc 5cm but not exc. 10cm wide finished rough complete all as specified and directed.
M&L Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending, spirally for hoping for columns hooking ends and binding with MS wire annealed not less than 0.90 mm dia complete all as specified and directed.
All as in item No 17 here-in-before but 6 to 8mm dia bars in stirrups, spacers and binders complete all as specified and directed.
Demolition of unreinforced concrete in ground floor and pavings not exc 15 cm thickness (below or above GL) complete all as specified and directed.
Taking down plastering in cement or cement lime plaster any thickness on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L Rendering 15mm thick in CM 1:4 with water proofing compound on stone/brick masonry surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L Rendering 15mm thick in CM 1:6 on fair faces of brick work or stone masonry surfaces in CM 1:6 and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L Rendering 5mm thick in CM 1:3 on concrete surfaces of ceiling and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L Cement concrete 1:5:10 type E2 using 40mm graded aggregate in foundations, filling etc complete all as specified and directed.
M&L Cement concrete 1:2:4 type B0 using 12.5mm graded aggregate in flooring 25mm thick complete all as specified and directed.
M&L 20mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
M&L Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L White Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Dismantling floor, hearth and wall tiling incl cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and as directed.
M&L Cement mortar 10mm thick cement mortar 1:4 on stone surface as backing coat ifinished rough complete all as specified and as directed.
M&L for White Glazed ceramic tiles in vertical surfaces 300mm x 200mm x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles complete all as specified and directed
S&F Vitreous china squatting pan ‘Orissa’ pattern, size 580 x 440 mm ISI mark, white with integral foot rests including provision of cement concrete bedding & ‘P’ or ‘S’ trap in repairs complete all as specified and directed
S&F Low level PVC flushing tank 10 litres capacity white with inlet ball valve float and handle including brackets, flush pipe of polyethylene low or high density PVC 32mm dia for low level cistern fixed in repairs complete all as specified and directed
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 500 litres hoisted and fixed in position including dismantling of existing water tank all as specified in SSR Part I complete all as specified and directed.
S&F Ball brass valves, 20mm bore high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
Dismantling of CI pipe joints in cement and taking out in trenches or in floor or wall of 75/100mm bore complete all as specified and directed.
S&F PVC SWR pipe single socketed in any length with rubber ring joints, 110mm bore, fixed to walls complete all as specified and directed.
S&F PVC SWR pipes single socketed in any length with rubber ring joints, 75mm bore on walls complete all as specified and directed.
S&F PVC SWR pipes single socketed in any length with rubber ring joints, 75mm bore on floors complete all as specified and directed.
S&F PVC SWR vent cowl 75mm bore complete all as specified and directed.
S&F PVC SWR bends any radius 75mm bore with acess door complete all as specified and directed.
S&F PVC SWR bends any radius 110mm with acess door complete all as specified and directed.
S&F 75mm PVC SWR floor trap plain with grating including jointing with solvent cement in repair complete all as specified and directed.
S&F PVC (SWR) Gully trap 125/110mm setting and jointing with solvent cement as in repair complete all as specified and directed.
S&F grating square 150mm size of PTMT complete all as specified and directed.
M&L Cutting chases for concealed water tubing and making good, cutting not exc 10cm girth complete all as specified and directed.
M&L Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4, type B-1, using 20 mm graded stone aggregate, smooth finished, and reforming benching as required, internal dia of pipe in 100 mm complete all as specified and directed.
S&F Vitreous china wash basin white flat back size 630x450mm but incl bracket including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe in repair complete all as specified and directed.
S&F 1 mm thick SS sinks made of kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F waste fittings 32mm dia brass chromium plated for sinks ,WHB etc with long screwed shanks and fly nuts flange end bedded in red lead cement and other end fixed, fix in repair complete all as specifiedand directed.
S&F 15mm pillar taps cast copper alloy with capstan heads, chromium plated screwed down high pressure ,with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe and fix in repair complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F CP fancy type Bib tap cast copper alloy with crutch or butterfly handle screwed and down screwed for iron pipe or for brass ferrule 15mm fix in repair complete all as specified and directed.
S&F CP fancy type Stop valve cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends iron pipe or for union 15mm bore or pipe in repair complete all as specified and directed.
S&F CP shower rose 125mm in repairs complete all as specified and directed.
S&F Shower arm 15 mm size , 195 mm long with bend of 45 degree with flange of PTMT any colour complete all as specified and directed.
S&F CP Tubular towel rail 20mm dia D type 600mm long between flanges brass in repair complete all as specified and directed.
Taking down chowkats or frames and not exc.1.5 Sqm each with shutters(without taking of shutters from the frame) complete all as specified and directed.
Taking down chowkats or frames but exc 1.5 Sqm and not exc 4 Sqm each with shutters(without taking of shutters from the frame) complete all as specified and directed.
M&L Cutting holes in brick work , exc one brick but n exc two bricks for inserting hold fast and making good dismantled portion in CM 1:3 complete all as specified and directed.
S&F Flat iron hold fast with FI 20 x3mm and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L Cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in hold fast block including necessary form work etc complete all as specified and directed.
S&F IInd class hard wood,plain solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
All as in item No.64 here-in-before but for with transoms and mullions, with double rebated on the solid and double rebated frame for fixing double shutters complete all as specified and directed.
S&F IInd class hard wood 30 mm thick plain, framed panelled door shutters(any number of panels) with panels of timber flat on both sides or of veneered particle board medium density wood particle board wit commercial face veneers supplied and fitted to chowkats etc complete all as specified and directed.
S&F IInd class Glazed and skeleton shutters,30 mm thick open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
All as item no.67 here-in-before, but divided into square, with plain; chamfered or rounded, mired and rebated sash bar etc complete all as specified and directed.
S&F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe-290 Gde E-165 complete all as specified and as directed.
S&F 3 mm thick sheet glass ,ordinary quality and glazing with oil putty in Square not exc. 0.5 Sqm in each pane complete all as specified and as directed.
S&F stainless wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S&F 150mm aluminum anodized barrel tower bolts of extruded section complete all as specified and as directed.
All as in item No 72 here-in-before but 200mm size complete all as specified and as directed.
S&F aluminum alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section or cast aluminum alloy 300mm long complete all as specified and as directed.
S&F stainless steel butt hinges medium weight; 100mm size complete all as specified and as directed.
All as in item No.75 here-in-before but 75mm size complete all as specified and as directed.
S&F extruded aluminum alloy handle fabricated type anodized 150mm complete all as specified and as directed.
All as in item No.77 here-in-before but item No.77 above but 100mm complete all as specified and as directed.
M&L Preparing new wooden surfaces over 10 cm width or girth and applying 2 coats of synthetic enamel painting over a coat of primer complete all as specified and as directed.
M&L Preparing surfaces of new steel of any description over 10 cm in width or girth and applying 2 coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
S&F Solid PVC door frame of sizes 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, as per specification and drawings complete all as specified and as directed.
S&F Factory made solid PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain coloured PVC “C” channel having a PVC sheet strip of 20mm width stock inside with solvent cement for stiles and plain colour PVC sheet for top rails, lock rails and bottom rails on either side and as gap insert for top rail & bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour of PVC sheet fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement etc complete all as specified and as directed.
M&L cement concrete 1:3:6 type C2 using 40mm graded aggregate 75mm thick for plinth protection finished even and fair without using extra cement complete all as specified and as directed.
M&L Complete removal of existing treatment on surfaces of wall by scrapping down old treatment, preparing surface even and smooth incl applying 1 mm thick wall care putty and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed
M&L Preparation of new plastered surfaces of walls, preparing surface even and smooth incl applying 1 mm thick wall care putty and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and as directed.
M&L for washing rubbing down and stopping of previously painted surfaces of wall (Plastered/ unplastered) and applying two coat of cement base paint all as specified and directed.
M&L Preparing of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of primer all as specified and directed.
M&L Preparing old plastered surfaces and applying two coats of white wash on wall complete all as specified and as directed.
M&L Preparing of new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and as directed.
M&L False ceiling using GI snap grid system with roll formed out of hot dip galvanised steel capping (powder coated) main runner 38x24mm, cross tee 29x24mm and wall angle 24x24mm members suspended with 4 mm dia GI wire carry maximum load upto 8.10 kg/Sqm with 4 mm thick designer ceiling board of any texture such as lake/hill/oceanic/cascade/Electra of M/s Everest ceiling grid system as per Regular T-2430, or equivalent make of "M/s Ramco/M/s charminar/M/s Amstrong" complete all as specified and directed.
Dismantling wall ceiling boards (fiber, pulp, insulation etc) or insulation boards, slabs, blankets,etc any thickness including cover fillets complete all as specified and as directed.
S&F Curtain rail CP with fixing brackets, stops, rollers etc complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including unserviceable fittings such as switches ceiling roses, pendants, regulators, switch/sockets of any type etc at site and making good the disturbed surfaces of walls, floors filling up of holes, plastering white washing distempering etc matching to the existing complete all as specified and as directed.
M&L Point wiring for one light/fan point 3/5 pin socket outlet/ independent /bell buzzer point/telephone point controlled by one switch with cable 1.5 Sqmm size PVC insulated (unsheathed) 1100 volts grade single core stranded (multistrand) copper conductor FRLS cable and drawing in and including non metallic rigid PVC concealed conduit medium grade inclusive of conduit fittings such as Bends Teess reducers etc and galvanized iron sheet steel terminal boxes of size 16 gauge thickness, light switches sockets with 3mm thick bakelite laminated sheet brass screws and cup washers including one continuous run of 1.50 Sqmm nominal area solidconductor PVC insulated unsheathed 1100 Volts grade single core FRLS cable with solid copper conductor green in colour with wire and connecting to earth dolly for the following complete all as specified and directed.
One light point controlled by one way switch complete all as specified and directed.
One Fan point controlled by one way switch complete all as specified and directed.
One Bell /Buzzer point controlled by one way switch complete all as specified and directed.
One 3/5 pin 5 Amps socket outlet on independent board complete all as specified and directed.
One 3/5 pin 5 Amps socket outlet on same board complete all as specified and directed.
All as per item Ser No. 94 here-in-before but with using copper conductor of 2.5 Sqmm for one 3/5 pin socket outlet 15 Amps on independent and using 2.5 Sqmm copper conductor as earth continuty cable compete all as specified and directed.
S&F Bell push flush type 5 Amps complete all as specified and directed.
S&F Switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified and directed.
S&F Socket outlet safety shutter 5 pin 5 Amps flush type all as specified and directed.
S&F Switch piano flush type one way 15 Amps SP complete all as specified and directed.
S&F Socket outlet polycarbonate 2 in 1 , 3 pin 5 / 15 Amps flush type complete all as specified and directed.
S&F Lamp holder insulated body of PVC / polycarbonate type with back plate suitable for Angle/ batten fittings complete all as specified and directed.
S&F Ceiling rose 3 terminals PVC / Polycarbonate insulated body 65mmx 50mm size complete all as spcified and directed.
S&F Bell ding-dong musical AC 230 Volts single pole complete all as specified and directed.
S&F Stepped type electronics fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed.
S&F Self ballast LED batten extruded theremoplastic body with PC diffuser in unique square shape > 120 degree wide distribution, 4 feet 20 W of LED batten 4 feet 20 W, CCT 6500 K Complete including connection upto ceiling rose with flexible copper twin twisted wire in repairs complete and all as specified and directed.
S&F Self ballast LED batten extruded theremoplastic body with PC diffuser in unique square shape > 120 degree wide distribution, 2 feet 10 W of LED batten 1 feet 8 W, CCT 6500 K Complete including connection upto ceiling rose with flexible copper twin twisted wire in repairs complete and all as specified and directed.
S&F Surface mounted LED Bulk Head luminaires 10 watts with ABS body & polycarbonate diffuser available in CCT 6000K IP 54 in repairs complete and all as specified and directed..
S&F Submain wiring with using two single core 6.0 SQmm copper multy stranded conductor PVC insulated and unsheathed (FRLS) cable and one single core 6.0 Sqmm copper multistandred conductor PVC insulated and unsheathed (FRLS) Earth wire using ISI MArked IS 694 1100 volts grade PVC insulated flexible stranded copper conductor wire drawn through with and including medium grade concealed PV C conduit ISI marked not less than 25 mm dia including conduit fitting and accessories complete including cutting cheses in existing wall of any descirption built in cement mortar and making good the disturbed surfaces in cement mortor (1:4) and finishing the surfaces to match with existing surfaces and finish termonatioin with bottle type copper lugs conduit being laid either in ceiling slab or wall or on surfaces or under the frame of the false ceiling including PVC flexible conduit or through wooden partition including clamping arrangement as required incl T/D of u/s submain wiring complete all as sepcified and directed . Note:- Two Run of 6.0 Sqmm cable and one run of 6.0 sqmm earth wire in and including conduit of suuitable size shall be measured as one unit).
S&F MCB SP 6-32 Amps breaking capacity 10 KA 'B' series 240 volts 50 Hz in repairs complete all as specified and directed.
S&F RCBO SP&N 40 Amps sensitivity 300mA, 240 volts AC, 50 Hz in repairs complete all as specified and directed.
S&F Double door MCB distribution board sheet steel powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral confirms to IS 13032- 1991 of 8 Ways in repairs complete all as specified and directed.
S&F LED Lamp 15 Watt in repairs complete all as specified and directed.
M&L Earthing complete with using GI earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using 4 mm dia GI Wire as earth lead moulded and retreived to earth plate at one end and connected to main switch / control board at another end with and including 15 mm dia GI light grade from upper end of earth plate upto external face of the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provison of PCC 1:2:4 type B-1 (Using 20 mm Dia graded stone aggregate) duly reinforced with mild steel round bar 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handle with and including necessarry excavation and earth work including laying the pipe concealed in floor / wall allas per plate NO-3 of SSR Part-I complete all as specified and directed and testing on completion. (Note:- If the desired resistance is not found earthing shall be done by the contractor at no extra cost to Govt).
Taking down the ceiling fan from site by disconneting electrically and refixing of the same after repair to existing location duly connectig electrically and removal of burnt winding by cutting, clening slots and re-Winding of AC celling fan motor 1200/1400 mm any make of fan with super enameled copper winding wire of existing gauge varnishing with E class insulation varnish. threading, including neceassry laith work and connnecting with appropriate size copper conductor cable upto connector block Complete all as specified and directed by Engineer-In-Charge . Notes:- (i) Doctor brand or equivalents ISI brand varnish shall only be used. (ii) Motor shall be wound with machine only. (iii) BIC/ HTP or DEVIDYAL make super enameled copper winding wire shall only be used. (iv) Rate are inclusive of dismantling and taking down of any type of fans from site for necessary repair work, Cu winding wire of existing gauge and twin twisted wire of suitable length from ceiling rose to Fan connector. (v) Capacitor,Ball Bearing, Shackle assy and down rod will be measured and paid separately.
S&F Gun metal bush of ceiling fan including neceassry laith, Grinding and welding work in repairs complete all as specified and directed.
S&F Capacitor AC 230 volts 2.5 mfd (ISI marked) in repairs complete all as specified and directed.
S&F Ball bearing of size 6200 to 6204 including neceassry laith , Grinding and welding work in repairs complete all as specified and directed.
S&F Shackle assembly kit (Rubber real -01, MS split clamp two Nos, nuts and bolts washers- 2 Nos & split pin -02 Nos) suitable for ceiling fan of 1200/1400mm sweep in repairs complete all as specified and directed.
S&F Down rod of ceiling fan of dia 20 mm bore "medium grade" complete with split pin, hanging clamp and rubber real (length of rod not less than 45cm and not more than 60cm) in white/brown colour (fully furnished) n repairs complete all as specified and directed.
S&F Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
DEEPAM BUILDERS & ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .