Municipal Commissionar, AMC
Rate contract for Miscellaneous Electrical works in various Offices and Building premises in NORTH zone of AMC.
301701
2025-26
Open
Miscellaneous Works
Ahmedabad
3 documents required · 2 mandatory · 1 optional
₹900
Municipal Commissioner, Ahmedabad
₹10,000
5 May 2026
5 May 2026
5 May 2026
14 May 2026
5 May 2026
Volume-I- TECHNICAL BID
Part-I :- General Specifications
PART-II :- Technical Specifications
1 Tender documents available On web site tender.nprocure.com
2 Last Date & Time of submitting the 14.05.2026 up to 6.00 p.m only on website
filled up tender online tender.nprocure.com
Last Date- Time and Place of up to 15.05.2026 4.00 p.m only At the Office of
3 submission of Volume-I (Technical Bid Tender Officer, Central Record Office, Mezzanine
only) of Tender in Physical form Floor, Block-B, Sardar Patel Bhavan, Danapith,
Ahmedabad-380 001,Gujarat,India
15.05.2026 at 4:05 p.m. onwards
Online Opening:-At the Office of Addl.Chief
Tender Vol-I (Technical Bid only) Engineer (Electrical), Light Department,5th Floor
4 Opening Date-Time and Place “C”-Block, Sardar Patel Bhavan, Danapith
Ahmedabad-380 001, Gujarat, India. Physical
Opening :-At the Office of Tender Officer, Central
Record Office, Mezzanine Floor, Block-B, Sardar
Patel Bhavan, Danapith, Ahmedabad-380
001,Gujarat,India or at the above said office
AHMEDBAD MUNICIPAL CORPORATION
ELECTRICAL DEPARTMENT
BRIEF TENDER NOTICE FOR WORK, TENDER FEE AND EARNEST MONEY DEPOSIT
S.N. WORK DESCRIPTION TENDER FEE E.M.D.
Rate contract for Miscellaneous Electrical Rs.900/- Rs.10,000/- in form
works in various Offices and Building (Non of demand draft/
1 premises in NORTH zone of AMC. Refundable) Bank guarantee of
Banks mentioned as
per Annexure-I only
Interested Only Eligible tenderer may obtain further information and clarification on
any matter relating to the tender documents from the Office of Additional Chief
Engineer (Electrical), 5th Floor, ”C”-Block Sardar Patel Bhavan, Danapith
Tender Fee-Demand Draft only
Tender must be accompanied by the Tender Fee through Demand Draft only in
favour of “Municipal Commissioner, AMC” payable at Ahmedabad from banks
mentioned in Annexure-I only with their tender documents.
Without tender Fee tender will be strictly rejected.
Earnest Money Deposit (E.M.D.) - D.D. or Bank Guarantee only
Tender must be accompanied by the E.M.D. through Demand Draft or Bank
guarantee in favour “Municipal Commissioner, AMC” payable at Ahmedabad of
banks mentioned in Annexure-I only with their tender documents.
Without E.M.D. tender will be strictly rejected. In case of BG Validity
shall be of minimum 6 months from last date of receiving of tender.
Payment of Tender Fee and Earnest Money Deposit
Tender Fee DD and EMD DD/Bank guarantee shall be submitted in electronic format
through online by scanning while uploading the bid. This Submission shall mean that Tender
Fee & E.M.D. are received for purpose of opening the bid. Accordingly offer of those shall
be opened whose tender fee and E.M.D. is received electronically. However for the purpose
of realization contractor shall attached original copies to the Office of Tender Officer,
Central Record Office, Mezzanine Floor, Block-B, Sardar Patel Bhavan, Danapith,
Ahmedabad-380 001, Gujarat, India. along with only Vol-I Physical copy.
Signature of the Tenderer Addl.Chief.Engineer
Name : (Electrical)
Company’s seal AMC
LIST OF BANKS FOR EARNEST MONEY DEPOSIT (E.M.D.), SECURITY DEPOSIT AND PERFORMANCE
Earnest Money Deposit / Security Deposit /Performance guarantee shall be in form of Demand Draft or Bank
Guarantee only of following banks only.
(A) Guarantee issued by following banks will be accepted as SD/EMD on permanent basis.
All nationalized Banks.
(B) Guarantees issued by following banks will be accepted as SD/EMD .
1) Commercial Banks :-
2. A U Small Finance Bank
3. Bandhan Bank
4. Barclays Bank
5. City Union Bank
7. DBS Bank India Limited
9. Equitas Small Finance Bank
10. ESAF Small Finance Bank
11. Federal Bank
16. IDFC First Bank
17. Jammu and Kashmir Bank
18. Jana Small Finance Bank
19. Karnataka Bank
20. Karur Vysya Bank
21. Kotak Mahindra Bank
22. South Indian Bank
23. Standard Chartered Bank
24. Tamilnadu Mercantile Bank
25. Utkarsh Small Finance Bank
(2) Co-operative and Rural Banks Of Gujarat :-
1. The Ahmedabad Mercantile Co-operative Bank Limited
2. Nutan nagrik Sahakari Bank Limited
3. Rajkot Nagarik Sahakari Bank Limited
4. Saraswat Co-operative Bank
5. SBPP Co-operative Bank
6. SVC Co-operative Bank
7. The Cosmos co-opretive Bank
8. The Gujarat State Co-Operative Bank
9. The Mehsana Urban Co-operative Bank Limited
10. The Surat District Co-operative Bank
11. The Surat Peoples Co-operative Bank
12. The Kalupur Commerical Co-operative Bank Limited
13. The Panchmahal District Co-operative Bank
14. The Baroda District Co-operative Bank
15. Baroda Gujarat Gramin Bank
16. Saurashtra Gramin Bank
Bank guarantee of above mentioned banks accepted only for Ahmedabad City branch only.
OR Bank Guarantee issued by any of the above mentioned bank branch in India must be approved by
a bank branch located in Ahmedabad city will be acceptable.
Signature of the Tenderer Addl. Chief Engineer
Company’s seal (Electrical)
VOLUME - I : TECHNICAL BID
PART - I : GENERAL SPECIFICATIONS
A-1 NOTICE INVITING TENDER
A-2 MEMORANDUM OF WORK IN BRIEF
A-3 SCOPE OF WORK
A-4 INSTRUCTIONS TO TENDERER
A-5 QUALIFICATION CRITERIA FOR TENDERER
PART - II : TECHNICAL SPECIFICATIONS
[B] TECHNICAL SPECIFICATIONS
PART - I : GENERAL SPECIFICATIONS
A – 1:- NOTICE INVITING TENDER
Municipal Commissioner,
Ahmedabad Municipal Corporation,
2nd Floor, "C"-Block,Sadar Patel Bhavan,
Danapith, Ahmedabad.
Gujarat, India.
Work- Rate contract for Miscellaneous Electrical works in various Offices and Building
premises in NORTH zone of AMC.
A.1.1 Here by a Percentage rate tenders (Two-Bid System) tenders are invited on behalf of
Municipal Commissioner , AMC by E-Tender system from the Contractor/ Agency
who qualify the Eligibility Criteria, as mentioned in Section–A.5 of the tender
A.1.2 Tender along with Conditions of contract shall be available from the website
tender.nprocure.com. Tenderer shall have to submit demand draft of banks
mentioned in Annexure-I only in favour of “Municipal Commissioner, AMC” Payable
at Ahmedabad of Rs. 900/- as tender fee along with the tender.
Tender received without tender fee shall be considered as Non-Responsive
and shall stand rejected outright.
A.1.3 Earnest Money Deposit (E.M.D.) shall be in the form of demand draft in favour of
“Municipal Commissioner, AMC” payable at Ahmedabad or bank guarantee from
banks mentioned in Annexure-I only of Rs.10,000/- with their tender documents.
Validity of Bank guarantee shall be of minimum Six months from
last date of receiving of tender. Tender received without Earnest Money shall be
considered as Non-Responsive and shall stand rejected outright.
A.1.4 SUBMISSION OF TENDER
A.1.4.1 Tenders shall be submitted together with the other documents that form the
tender. In the event of a Contract, the tender and the documents attached there to
shall be considered as forming part of the Contract Documents.
A.1.4.2 Two set (One Original + One Xerox) of tender documents consisting of following
shall be submitted
VOLUME-I TECHNICAL BID
Separate envelop for Tender fee (D.D. only)
Separate envelop for E.M.D. (D.D. or Bank guarantee)
Part – I : (Section – ‘A’) – Tender Notice, General Conditions-special condition of
Contract, Specifications –Non Technical etc.
Part – II : (Section – ‘B’ ) – Technical details and Technical Specifications
Addendum, if any
All the pages of tender documents has to be stamped and signed by the Tenderer
VOLUME-II FINANCIAL BID
As this tender is E-tender tenderer must have quote price Bid as per format
of N-procure site online only.
A.1.4.3 Two sets (One Original + One Xerox copy) of tender documents- Vol-I only
(Including technical specifications, drawings and addendum (if any) duly completed
in all respects, tender fee, EMD and other documents required (hard copy of
original certificate, data sheets, company details, forwarding letters etc.) shall be
submitted, so as to reach at the . " Tender Officer, Central Record Office,
Mezzanine Floor, ”B”-Block,Sardar Patel Bhavan, Danapith, Ahmedabad –
001,Gujarat (INDIA) "
A.1.4.4 All Envelops and sub envelops must be sealed by tenderer & each sealed envelope
shall show on the outside, the following details
(a) Name of Department
(b) Name of Work
(d) Name of Contractor
(e) Last date of receiving tender in Physical Form by the AMC
(f) Date of opening of Vol-I (Technical Bid only)
Tenders which are opened before the due date for tender opening with
no indication having been given on the outside of the envelope or container to
indicate that; is a tender liable to be disqualified.
A.1.4.5 The tender shall be considered non-responsive if tender documents are not
sealed. Tenderer shall not be allowed to fill in or seal their tenders at AMC Office.
Tenderer are requested to submit the tenders well in time before stipulated date
and time of receipt; so as to avoid rush at the closing hours.
A.1.5 Security Deposit
The Contractor shall have to pay Security Deposit worth 5% amount (or as per
the latest circular of AMC) of the total ordered Value in Indian Rupees in approved
Form “A” enclosed or other format acceptable to AMC within 15 days from
receiving date of L.O.I./Work Order in form of Demand Draft or Bank Guarantee
from banks mentioned in Annexure-I only with requisite amount of contract paper.
Failure of submitting security deposit within 15 days may lead to cancellation of
work order and in those case Municipal Commissioner has all right to forfeit EMD
amount deposit along with tender and have right for all strict actions against
A.1.6 The Earnest Money Deposit of all the Tenderer except 1st, 2nd and 3rd lowest shall be
returned as early as possible.
A.1.7 All details and schedules required for pre-qualification and technical evaluation
shall be submitted in hard copy in prescribed format.
A.1.8 Financial bid shall be submitted only on online on tender.nprocure.com
A.1.9 The technical bid containing Vol-I (technical bids only) from the tenderer received,
shall be opened Online/Physical in the presence of the tenderer’s representatives
who may remain present at sharp time of the day fixed for tender opening and the
technical tenders shall be scrutinized by AMC or his authorized representatives for
satisfying various eligibility criteria prescribed for the tenderer for this work.
After this, the Financial Bids of only technically qualified tenderer will be opened
online. The actual date and Place of opening of Vol-II-Financial Bid of tenderers
shall be communicated to technically qualifying tenderer only later after scrutiny
of tender documents.
A.1.10 The Conditional Tender will not be accepted and shall be rejected outright, unless,
the nature of condition(s) put up by the tenderer is acceptable to AMC. Any
suggestions/alteration from the tender must be mentioned in the main
forwarding letter. Bidder is advised to visit the particular site for said work under
this tender to study the local site condition prior to tendering. Request for any
kind of change (including prices) shall not be entertained under any
A.1.11 The tenderer should quote his Price bid premium/Discount (% Above/ Below)
online as per Vol-II format of website tender.nprocure.com only.
A.1.12 Incomplete tender which does not fulfill any of the above conditions shall be liable
for rejection. Tender shall also be liable to be rejected if –
i) The Tenderer proposes any alteration in the work specified or in the time allowed
for carrying out the work or any condition in the covering letter which is not
acceptable to AMC.
ii) The bidder or the person authorized to sign on behalf of the bidder does not sign
the all pages of the tender and amendments if any (digitally online).
iii) All corrections, additions or pasted slips are not initialed by the authority person
having power of attorney
iv) Any Changes/ Modification in any text, documents in original tender documents
published in N-procure web site.
v) Any erasure/modification in original tender documents published in N-procure site.
vi) The tenderer or in the case of a firm the bidder or the person authorized to sign on
behalf of the bidder shall sign the bid document. The Copy of legal status of
bidder( Partnership Deed or Articles of Association of the Company) along with
power of Attorney to sign on behalf of the bidder will be furnished along with
other documents to be dispatched physically.
vii)Tender submitted without signing relevant pages of the tender and amendments, if
viii)All Technical data sheet not furnished by the tenderer.
A.1.13 Acceptance of the tenders shall rest with the competent authority of AMC, who
does not bind himself to accept the lowest tender.
A.1.14 Municipal Commissioner, AMC reserves the right
(i) To change, alter or to waive any technical or commercial terms, conditions and
(ii) To reject all the tenders or the lowest or any other tender in part or full without
assigning any reason whatsoever at any stage
(iii) For making changes / relaxation in eligibility criteria at any time
(iv) To split the tender in to two or more agencies
The Tenderer shall have no cause of action or claim against the corporation
or -its officers, employees, successors or assignee for rejection or split of tender.
A.1.15 It must be clearly and distinctly understood that the conditions of contract and
specifications shall be rigidly enforced and no relaxation on the grounds of customs
prevailing shall be allowed.
A.1.17 The Price quoted for work must be of Site / Store delivery of Corporation with
prevailing applicable taxes.
After awarding Contract and during contract implementation if Government taxes
increases or any type of Govt taxes added then the same rise /addition will given to
Contractor upon submission of necessary documents as mentioned below.
Gazette of Government indicating changes in taxes
Copy of Chillan of tax that has been submitted to income tax department
Other documents as demanded by client
However during Implementation of work if any types of taxes reduces or any type
of Govt taxes is removed then the same shall be recovered from Contractor
.However it is Contractor’s responsibility to inform the same to Client with
supporting documents.
A.1.18 The tender for the work shall remain open for a period of 120 days from date of
opening of Price Bid and the tenderer shall not be allowed to withdraw or modify
the offer on his own during this period.
A.1.19 Tender documents are not transferable.
A.1.20 Any False information given in the tender will invite invalidation of any Contract
awarded on the basis of such false information at the discretion of the
A.1.21 The tenderer, if directed by the Engineer in charge; shall increase or decrease the
strength of the labour both skilled and unskilled. The Contractor shall also report of
any accident which may have occurred within 24 hours of its occurrence to the Add.
Chief Engineer (Electrical).
A.1.22 The tenderer shall carefully read the eligibility criteria, furnish the details and satisfy
the same; otherwise the tender shall be rejected without assigning any reason.
A 1.23 Contractor shall solely responsible for any issue arises related to Provident fund and
ESIC of their deployed staff. AMC will not responsible for the same
A.1.24 For Any Inquiry/Query/Suggestion interested participants may write letter to the
Office of Add. Chief Engineer (Electrical) as above mentioned address 7 days before
last date of tender online submission. After that any letter submitted not
A.1.25 The bidder is required to check the website tender.nprocure.com for Addendum if
any before 48 hours of last date and time of on line tender submission. The
bidder who quotes the bid without attaching the addendum shall be rejected.
Addendum is a part of tender and the tenderer who quotes the tender without
attaching the addendum will be rejected.
I/We hereby do certify that I / We have read above instruction
A.1.1 to A.1.25 of “Notice Inviting Tender” carefully and understood very well and taken
into account while tendering and have quoted our firm price accordingly.
Signature of the Tenderer Addl. Chief Engineer
Name (Electrical)
Company’s seal AMC
A – 2: MEMORANDUM OF WORK IN BRIEF
CLIENT: AHMEDABAD MUNICIPAL CORPORATION
WORK- Rate contract for Miscellaneous Electrical works in various Offices and Building
premises in NORTH zone of AMC.
S.N. DESCRIPTION DETAILS
Tender Documents to be
1 tender.nprocure.com
downloaded from
Last date for submitting 14.05.2026 up to 6.00 p.m only on website
2 tender.nprocure.com
filled up tender Online
Last Date- Time and up to 15.05.2026 4.00 p.m only At the Office of Tender
Place of submission of Officer, Central Record Office, Mezzanine Floor, Block-B,
3 Volume-I (Technical Bid Sardar Patel Bhavan, Danapith, Ahmedabad-380
only) of Tender in 001,Gujarat,India
15.05.2026 at 4:05 p.m. onwards
Online Opening:-At the Office of Addl.Chief Engineer
Tender Vol-I (Technical (Electrical), Light Department,5th Floor “C”-Block, Sardar
Bid only) Opening Date- Patel Bhavan, Danapith , Ahmedabad-380 001, Gujarat,
Time and Place India. Physical Opening :-At the Office of Tender Officer,
Central Record Office, Mezzanine Floor, Block-B, Sardar
Patel Bhavan, Danapith, Ahmedabad-380 001,Gujarat,India
or at the above said office
Mode of sending In sealed envelope in (One Original + One Xerox copy)
Physical tender copies by Registered Post A.D. or Speed Post or Hand
5 delivery only.
documents, Vol-I
(Technical Bid only) Tender sent by ordinary post shall be rejected outright.
a) Name of Department
b) Name of Work
Description Essential to c) Tender No.,
6 be made on each sealed d) Name of Contractor
envelop e) Last date of receiving tender in Physical Form by the
f) Date of opening of Vol-I(Technical Bid only)
Mode of Quoting Rates
7 in Schedule of Rates/ As per format of N-procure web site tender.nprocure.com.
At the time of opening of tender only Vol-I (Technical bid)
of tenders will be opened . After scrutiny of Vol-I (Technical
8 Tender opening
Bid), the Vol-II (Financial Bid) of Qualified tenderer will be
Only demand draft of Rs.900/- in favour of “Municipal
Tender Fee (Non -
9 Commissioner, AMC” payable at Ahmedabad from Banks
mentioned in above Annexure-I only.
In form of Demand Draft in favor of ”Municipal
Commissioner, AMC” payable at Ahmedabad or Bank
guarantee from banks mentioned in Annexure-I only of Rs
10,000/- BG Validity shall be of minimum 6 months from
last date of receiving of tender.
11 Tender Validity Period 120 Days from date of opening of Vol-II Price Bid
5% amount (or as per the latest circular of AMC) of the
Total Ordered value to be submitted by the way of D.D. or
Bank guarantee from the banks mentioned in Annexure-I
only in favour of “ Municipal Commissioner, AMC”with
12 Security Deposit (S.D.) requisite amount contract paper.
In case of Bank guarantee validity period should be
minimum 1 year and if work is continue after one year
then contractor to extent the same as per instruction of
engineer in charge.
13 Price Escalation Not Allowed
The Rates for Extra item of any nature of Electrical work
shall be Considered of lesser value of following
(a) Current S.O.R.(Of that year the extra work carried
14 Extra Item Work out)
(b) Tender S.O.R.(after effect of Tender Premium /
(c) Market Rate
The quantities shown in the schedule of quantities are
intended to cover the entire work indicated in the
Excess Quantity work drawings, but the employer reserves the right to execute
only a part or the whole or up to any excess / lesser thereof
without assign any reasons therefore and contractor has to
execute it without any objection.
Date of Commencement From Date of receiving Work Order/L.O.I
The Contractor shall have to make himself acquainted with
all conditions and situations pertaining to site. The rates
quoted with all conditions and situations pertaining to site.
17 Site Conditions The rates quoted by contractor shall taken into account all
site factors and no extra cost shall be payable on any
account especially on the plea that the contractor was not
aware of any particular situation or condition.
100% Payment will be made after satisfactorily completion
18 Mode of Payment
Rate contract for Miscellaneous Electrical works in various
Total Work Completion Offices and Building premises in NORTH zone of AMC.
Period within limit of Rs.10.00 Lacs.
In case of major/minor faults, whenever AMC handover
fault to contractor then will have to rectify fault within
hours. If contractor fails to do the same, penalty will be
deducted by AMC from contractor bill. Penalty will be (1)
Emergency single /three phase short circuit/current/power
supply failure etc. electric fault not attend up to 2-4 hour
Liquidated damages /
20 after receive complain, otherwise Rs.500/- penalty per
complain. (2) Major electric fault not attend up to 1 day
after receive complain, otherwise Rs.1000 penalty per
complain. (If any above situation continues for three times
.then AMC reserves the right to terminate the contract
IMORTANT INSTRUCTIONS
tenderer shall be fill the Format as mentioned in Schedule A-2 (A2.1 to A2.2) of
Technical tender, Volume-I.
Contractor shall have to submit all the documents spiral binding having proper
checklist index indicating the page no. as per format and supportive documents.
Signature of the Tenderer Addl.Chief Engineer
Name (Electrical)
Company’s seal AMC
INDEX FOR SCHEDULES
S. N. DESCRIPTION
A.2.1 STRUCTURE ORGANISATION AND QUALIFICATION OF FIRM
A.2.2 INFORMATION REGARDING FINANCIAL CAPACITY OF THE BIDDER
SCHEDULE-A.2.1 :- STRUCTURE ORGANISATION AND QUALIFICATION OF FIRM
S.N. DETAILS TO BE FILLED BY THE BIDDERS
1 Name of the Vendor / Applicant
2 Nationality of vendor/ Applicant
Address of the firm Main Office
3 Telephone No.
Address of office at Ahmedabad .
4 Telephone No.
5 Date of Incorporation of the Company.
6 Nature of the Company of the Applicant
a A proprietary firm Yes / No
b A firm in partnership Yes / No
c A Private Limited Company Yes / No
d A Limited Company Yes / No
e Any other Yes / No
Tick whichever is applicable and strike out others
Attach a copy of Partnership Deed / Certificate of
Incorporation / Articles of Association and
Memorandum of Association etc.
7 Name and address of person (s) holding power of
attorney with Contact no.
(Attested copy of power of attorney to be
8 For how many years has your organization been in
business of similar work under it’s present name?
9 Details of GST registration with date.
10 Details of Permanent Account Number(PAN)
11 Were you ever required to suspend execution for
period of more than Six months continuously after
you started? If so, give the name of project and
reasons there of
12 In how many of your projects penalties were imposed
for delays? (Please give details)
13 Financial details, Solvency certificate etc
14 Annual turnover for the last three years ending March-
2025 Fill Details as per section A
15 Gross capital for the last three years ending March-
16 Statement of Profit & Loss during last three years
ending March-2025
Signature of the Tenderer Addl. Chief Engineer
Name (Electrical)
Company’s seal AMC
SCHEDULE-A.2.2 :-INFORMATION REGARDING FINANCIAL CAPACITY OF THE BIDDER
S. Details Submitted Amount Details to Remarks
N. Yes/ No in Rs be
1 Tender fee Tender fee value shall be Rs.900/-
2 E.M.D EMD value shall be Rs.10,000 /-
The contractor must possess
solvency certificate of value not
3 Solvency less than Rs. 2,00,000/- from
Certificate Nationalized / Scheduled Banks
only. Solvency Certificate should
not prior to one year old from last
date of tender submission.
turnover for Minimum average Annual
last 3 years Turnover for last three financial
2022-23 years shall be Rs.3,00,000/-
2023-24 Certificate duly signed and
stamped from C.A. shall be
2024-25 attached with this schedule along
with the audited balance sheets for
AVERAGE the last three years showing long
term profitability.
5 Profit earned
three years Certificate duly signed and
stamped from C.A. shall be
2022-23 attached with this schedule along
S. Details Submitted Amount Details to Remarks
N. Yes/ No in Rs be
6 Gross Capital
during last Certificate duly signed and
three years stamped from C.A. shall be
2022-23 attached with this schedule along
7 Price of Mention Amount and year where
Biggest job completed
8 Experience of Separate sheet should be enclosed
execution of with this schedule as supporting
maintenance documents.
return copy of Copy shall be attached with this
last three schedule.
Note: (1) No Deviation with respect to technical guaranteed parameters and commercial
terms shall be acceptable.
(2) If required separate sheet can be used for more details.
Signature of Tenderer Addl. Chief Engineer (Electrical)
A-3: SCOPE OF WORK AND SPECIAL INSTRUCTIONS TO CONTRACTOR
The scope of work under this contract comprises Rate contract for Miscellaneous Electrical
works in various Offices and Building premises in NORTH zone of AMC. The work shall be
carried out and completed under this contract in every respect in conformity with the
current rules and regulations of the local authority, the Indian Standard Institution or other
relevant codes, and with the directions of and to the satisfaction of the Client.
GENERAL INSTRUCTIONS
A.3.1 The details for Rate contract for Miscellaneous Electrical works in various Offices and
Building premises in NORTH zone of AMC shall be as per design and instructions of
Engineer-in-Charge and his order shall be considered final.
A.3.2 The Contractor shall have to properly store the material brought by him on site. This shall be
kept open for inspection by Client and authorized representatives.
A.3.3 The Contractor shall remain responsible for workmen’s compensation, if any, when such
case occurs. The contractor shall arrange for red lamps at night and fencing and shall be
responsible for any damage of life and limb or property, if any happens, during the
execution of work. In case of dispute for unseen or overlooked items, the decision of
Municipal Commissioner, AMC shall be final. The Contractor shall have to give site clean of
all rubbish on completion of work and hand over the site with final finishing of the work as
directed. All the rejected materials shall be removed from site within 24 hours by
Contractor at his risk and cost.
A.3.4 All the materials required for the execution of works shall have to be brought by the
contractor from open market.
A.3.5 Contractor shall be fully responsible for compliance of the various provisions under Contract
Labor Act, 1970 and latest addendum and the Rules frames there under. The Contractor
should obtain necessary permissions, license & registrations from labour commissioner, as
per labour law.
A.3.6 All the precautionary measures for safety are to be taken by the contractor during execution
of work at site.
A 3.7 No Contractor shall employ any child heaving age 5 years to 14 years, as it is prohibited by
the Child Labour Prohibition and Regulation Act, 1986.The Hon. Supreme Court has
given certain guidelines and as per the guidelines, if employment of child labour is
detected on the site work, the employer i.e. the Contractor shall have to deposit
Rs.20,000/- (Rupees Twenty Thousand only) in the Child Labour welfare Fund. If the
employer refuses to deposit, then action will be taken for contempt of Court of the
Supreme Court Judgement and also will be prosecuted by the concerned authority.
A 3.8 AMC will not be responsible for any accidents (In case of the death of a person or an injury)
occurred in the any premises of AMC Area due to the above reason and the compensation
for the family of the person affected. It will be in the scope and responsibility of the
contractor to deal with the legal proceeding such as court matter, police case
compensation etc which arises due to the above reason.
A3.9 AMC reserves the right to inspect any Equipment / Material to be supplied by the contractor
as part of his /her scope of work, at manufacturer’s works to confirm their conformity to
the Contract. All the expanses to be bare by contractor.(travel by air stay at deluxe hotel)
I/We hereby do certify that I/We have read above instruction A3.1 to A3.9 of
“Scope of Work” carefully and understood very well and taken into account while
tendering and have quoted our firm price accordingly..
Signature of the Tenderer Addl.Chief Engineer
Name (Electrical)
Company’s seal AMC
A – 4:- INSTRUCTIONS TO TENDERER
A.4.1.1 These instructions are provided to assist tenderer while preparing their tenders.
A.4.2 INVITATION TO TENDER
A.4.2.1 The Municipal Commissioner, AMC shall receive tenders for Rate contract for
Miscellaneous Electrical works in various Offices and Building premises in NORTH zone
of AMC according to the specifications and Schedule of Quantities and in the tender
documents herewith attached.
A.4.2.2 Tenders shall not be accepted after the hour and date fixed for receiving of tenders.
Telegraphic tenders shall not be accepted under any circumstance. Tenders received
after the hour and date so fixed shall not be considered. Tenders shall be received only
by Regd Post A D / Speed Post / Hand delivery on or before due date and time as
mentioned in Tender notice. Tenderer’s authorized representatives may attend the
tender opening. The tenders shall be opened at the date and time as mentioned in
A.4.3 TENDER VALIDITY PERIOD
A.4.3.1 The tender shall be kept valid for acceptance for a period of 120 Days (One Hundred
twenty days) from date of opening of Price Bid.
A.4.4 LANGUAGE OF TENDER
A.4.4.1 Tenders shall be submitted in English, and all information in the tender shall be in
English. Information in any other language shall be accompanied by its translation in
English. Failure to comply with this may disqualify a tender. Only English text shall be
A.4.5 INCOME TAX RETURN
The tender must be accompanied by an Income-Tax return copy of last three financial
years ending March
A.4.6 Joint Venture: Not Applicable
A.4.7 MODIFICATION OF DOCUMENTS
A.4.7.1 Modifications of specifications and extension of the closing date of the tender, if
required, shall be made by an Addendum. Copies of each Addendum shall be put up on
website tender.nprocure.com. These shall be signed and submitted along with tender
documents by the tenderer and shall form a part of the tender document.
A.4.8 Evaluation of Tenders / Documents -Information to be submitted along with Volume
– I (Technical Bid)
The Contract will be awarded on the basis of overall lowest prices as per N-procure Vol-II.
A.4.9 SIGNING OF CONTRACT
A.4.9.1 The successful tenderer shall be required to execute the Contract within 15 days of
receipt date of Work Order/ L.O.I. If the contractor shall not pay security deposit and
shall not sign agreement within 15 days after issuing the first letter from the authority
of AMC, EMD shall be forfeited and such tenderer shall be disqualified for getting
further any work in AMC.
A.4.10 STAMP DUTY AND LEGAL CHARGES It shall be incumbent on the successful tenderer to
pay stamp duty on the contract and legal charges for preparation of the contract
A.4.11 Not More than one tender shall be submitted by a contractor or by a firm of contractor.
No two or more concerns in which an individual is interested as a proprietor and/or a
partner & /or director shall submit tender for the execution of the same work/tender. If
they do so all such tender shall be liable to be rejected.
A.4.12 Any objection/Complaints regarding tender can be done by any applicant/tenderer in
period between technical bid opening and price bid opening. In case any applicant is
complaining after the price –bid is opened then it will be considered as bidder/applicant
is trying to harm the tender process and complainant/Bidder will be Debar for 5 yrs for
tender process in AMC and Earnest Money Deposit will be seized. If the complaint is not
done by applicant then file will get close (case no longer) without checking.
A.4.13 Even though the bidders meet the above criteria, they are subject to be rejected, if
they have record of poor performance such as abandoning the work, not properly
completing the contract, inordinate delays in completion, financial failures etc.
A.14 DECLARATION FORM
A.14.1 I/ We hereby declare that I / We have perused in detail and have examined closely the
specifications/scope of work/general terms and conditions/special terms/important
instructions/note described in the tender document. I / We hereby agree to be bound
by and comply with all such specifications/terms, conditions etc.
A.14.2 I / We also certify that I / We have visited the sites and inspected the locations of the
proposed work before quoting my/our rates and will not claim any extra towards
minor/major item related the job.
A.14.3. I/We also confirm that I/We have understood intent and content of the tender and
I/We assure that I/We shall abide by all intents of the tender besides its wordings.
A.14.4 I/We also confirm that my/our offer is strictly in line with tender
stipulations/terms/conditions and understand that deviation of any kind, if found, my
/ our offer will be summarily rejected.
A.14.5 If due to any reason, payment is delayed then tenderer is not eligible to claim/demand
any compensation for loss of interest thereof.
A.14.6 AMC reserve the right (i) to change, alter or to waive any technical or commercial terms,
condition and qualification (ii) to reject all the bids or any bid in part or full without
assigning any reason whatsoever (iii) for making changes / relaxation ineligibility
criteria at any time (iv) to split the order work and award the work to more than one
tendered with lowest rate quoted in the tender in the interest of the public. The bidder
shall have no cause of action or claim against the Ahmedabad Municipal Corporation or
its Officers / Employee’s successor or assignee for rejection of his tender/bid,
A.14.7 In case of not filling and submitting of documents as mentioned in tender at the time of
tendering the no further correspondence shall be done with bidders for further
submission of either technical or commercial documents or any discount, and at the
same time tender will be rejected.
A.14.8 To remove all clay, sand, debris accumulated at site from excavation work or any other
kind of waste material from site as per instruction of E-I-C without any extra cost.
A.14.9 To provide the site to E-I-C for inauguration work after completion of tender work in all
respect removing all raw materials, grass, debris or any kind of waste material from site as
per instruction of E-I-C without any extra cost.
A.14.10 Contractor shall make all arrangements for obtaining power connection, the installation,
operation, maintenance and subsequent removal of temporary supply of electricity. AMC
shall issue only authorization letter to Contractor for obtaining power connection, and yet if
power is not available in time, the work shall not be postponed and the Contractor shall
have to arrange for diesel generating set (s) at his own cost.
A.14.11 Contractor must present regularly and timely whenever work progress review meeting
regularly arranged by department during period of starting of tender work at site to the end
I/We hereby do certify that I/We have read above instruction A.4.1 to A.14.11
“General Rules and Directions for the Guidance of Contractors”carefully and
understood very well and taken into account while tendering and have quoted our
firm price accordingly..
Signature of the Tenderer Addl.Chief Engineer
Name (Electrical)
Company’s seal AMC
EARNEST MONEY DEPOSIT / SECURITY DEPOSIT
In consideration of the AHMEDABAD MUNICIPAL CORPORATION (hereinafter to as the
corporation) having agreed to exempt ______________________________________
(hereinafter referred to as "the said Contract") from the demand of earnest money /
security deposit in cash for the due fulfillment of the terms and conditions of the
agreement made between the AMC and the said TENDERER on
(hereinafter referred to us "the said agreement") on production of Bank Guarantee for
(hereinafter referred to as "Bank") do hereby undertake to pay to the AMC as a amount not
exceeding Rs. _____________________________ Rupees
on the demand from AMC.
Any such demand on the bank shall be conclusive as regards as amount due and payable by
the bank under this guarantee. However, liability of the bank under this agreement shall
restricted to as amount not exceeding Rs. ___________________________ Rupees
We the bank further agree that the guarantee herein contain shall remain in full force and
effect during the period that would be mentioned in the tender and that it shall continue to
be enforceable till all the dues of the Corporation under or virtue of the said agreement
have been paid and its claim satisfied or discharged and till a certificate to the effect has
been received by the bank from the Corporation. However, unless the demand of claim
under the guarantee is made to the bank in writing on or before the
_____________________ (specify the date) the bank shall be discharged from all liabilities
under this guarantee.
With the bank further with AMC shall have fullest liberty, without the concert of the bank
without effecting in any manner it obligations herein under to vary any of the terms and
conditions of the said agreement or extend time for validity by the said tender from time to
time or to postpone for any time or from time to time any of the powers exercisable by the
AMC against the said Contractor and to forebear to enforced any of the terms and
conditions relating to the said agreement and the bank shall not be relieved from liability by
reason of any such variation, or extension granted to the contractor for any forbearance, at
Contractor or by any such matter or thing whatsoever which under the law relating to
sureties would, but this provision, have the effect of so relieving the Bank.
undertake not to revoke the Guarantee during currency except with the previous concert of
the AMC in writing.
Principal (Contractor)
Contract No. And date of Contract
PERFORMANCE BOND
(The date of this bond must not be prior to the date of the instrument in connection with
which it to given)
Principal (Contractor)
Sub of bond (Express in words and figures)
Contract No. And date of Contract
A – 5: ELIGIBLITY/QUALIFICATION CRITERIA FOR TENDERER
Qualification will be based on meeting all the following minimum pass / fail criteria regarding the
bidder’s general and particular experience, personnel and equipment capabilities and financial position.
The AMC reserves the right to waive minor deviations, if they do not materially affect the capability of a
bidder to perform the contract.
1. Tenderer must have to submit demand draft of banks mentioned in Annexure-I only in favour of
“Municipal Commissioner, AMC” Payable at Ahmedabad of Rs.900/- as tender fee along with the
2. Tenderer must have to submit Earnest Money Deposit (E.M.D.) in the form of demand draft or bank
guarantee in favour of “Municipal Commissioner, AMC” payable at Ahmedabad from banks
mentioned in Annexure-I only of Rs. 10,000/- with their tender documents.
4. The tenderer must possess current validity valid Electrical Contractor License from Gujarat State or Any
State Licensing Board of India.(Copy of license must be attached along with tender)
5. Experience of having successfully completed similar works during last 7 years ending last day of month
previous to the one in which tenders are invited should be either of following.
(i)One similar work completed costing not less than the amount of Rs.8,00,000/- (80 % of the
estimated cost .) OR
(ii)Two similar works completed costing not less than the amount of Rs.5,00,000/- (50% of the
estimated cost.) OR
(iii)Three similar works completed costing not less than the amount of Rs.4,00,000/- (40% of the
estimated cost.)
Defination of similar work
Similar works mean Maintenance work of Electrical Installation In offices and buildings / Community
Hall / Party Plot / Auditorium of any Govt. / Semi Govt. / State Govt. organization /Railway /Municipal
Corporation only (Copies of Work order and work completion certificate of nature of work must be
submitted with tender in proof of above criteria)
NOTE:- Water pumping station, STP and Street Light work or Only Labor work will not be considered as a
similar nature work.
6. Average Annual financial turnover in last three financial years ending on 31.03.2025 shall not be
less than value of Rs 3,00,000/- (30% of estimated value.)
6. Solvency Certificate
The tenderer must possess solvency certificate of value not less than Rs.2,00,000/- from Nationalized /
Scheduled Bank only.(20% of tender value) Solvency Certificate should not prior to one year old from last
date of tender submission.
7. Litigation History
The bidder should provide accurate information on any litigation history or arbitration resulting from
contracts completed or under execution by him over the last 10 years. This should also include such
cases, which are in process/progress. A consistent history of awards against the bidder or any partner of
a firm may result in failure of the bid. In case the bidder has not provided such information and has come
to the notice of the Authority, the bid shall be rejected at whatsoever stage and in such case all the
losses that shall arise out of this issue shall be recovered from the bidder/contractor and he shall not
have any claim for the same.
Signature of the Tenderer Addl. Chief Engineer
Name (Electrical)
Company’s seal AMC
TECHNICAL SPECIFICATIONS
B.1 TECHNICAL SPECIFICATIONS
B.2 APPLICABLE STANDARDS
B.3 LIST OF APPROVED MAKES
B.1 TECHNICAL SPECIFICATIONS
Material Specification
Section - 1 Distribution Board
Section – 2 LT Cabling and Termination
Section – 3 Internal Wiring
Section – 4 Earthing
Section-1 Distribution Boards
It includes Supply, Installation, Testing and Commissioning of Distribution Boards
standard company fabricated or to be fabricated by fabricator.
1.2 Standards :
IS : 8623 : Distribution Boards
1.3 Distribution Boards :
a) Distribution boards along with the controlling MCB's/Fuse or Isolator as shown shall be
fixed in an M.S. Box with hinged door suitable for recessed mounting in wall.
Distributionboards shall be made of minimum 18 SWG steel sheet duly rust inhibited
through aprocess of de-greasing, acid pickling, phosphating and powder coated to an
approved colour of adequate micron rating duly approved by architect/consultant.
Three phase boards shall have phase barriers and a wire channel on three sides. Neutral
bars shall be solid tinned copper bars with tapped holes and chase headed screws. For
phase DB's, 3. Independent neutral bars shall be provided for per phase isolation in
addition to main neutral links.
b) Conduit knockouts shall be provided as required/shown on drawings and the entire board
shall be rendered dust and vermin proof with necessary sealing gaskets. The top and
bottom side of DB should be detachable.
c) All DB's shall be internally pre-wired using copper insulated Busbars of appropriate rating.
Bus bars shall be suitable for the incoming switch rating and sized for a temperature rise
of 35° C over the ambient. Each board shall have two separate earthing terminals. Circuit
diagram indicating the load distribution shall be pasted on the inside of the DB as
instructed. Two earthing terminal for single phase and two terminals for 3 phase DB's
shall be provided with one earth strip connecting the studs and the other earth link
should be provided with base insulator in such a way that link should in contact with
body of distribution board.
A) The RCCB should suffices all the requirements of IS as per code IS -
( Part I ) - 2000. The RCA should be current operated and not on line voltage.
B) The RCCB/RCCB should ensure mainly the following functions.
1) Measurement of the fault current value.
2) Comparison of the fault current with a reference value.
C) The RCCB/RCBO should have a torroidal transformer which has the main conductors of
primary (P - N) which check the sum of the current close to zero. All metal parts should
be inherently resistant to corrosion and treated to make them corrosion resistant. It
should be truly current operated. It should operate on core
balance torroidal transformer. It’s accuracy should be ± 5 %.It should operate even in
case of neutral failure. It should trip at a present leakage current within 30 M.S. It’s
enclosure should be as per IP 30.It’s mechanical operation life should be more than
20,000 operations. It should provide full protection as envisaged by IE
rules - 61-A, 71 - ee, 73 - ee, 1985 and also rule 50 of IE rule1956.It should conform to all
national and international standards like IS, BS 4293 - 1983, CEE 27 (International
commission Rules for the approved of electrical equipment).
1.5 MCB/ Isolators:
Miniature circuit breakers shall be quick make and break and break type conform with
British standard BS:3871 (Part-I) 1965, IEC 898-1995 and IS :8828 (1996). The housing of
MCBs shall be heat resistant and having a high impact strength. The fault current of MCBs
shall not be less than 10000 amps, at 230 volts. The MCBs shall be flush mounted and shall
be provided with trip free manual operating mechanism with mechanical "ON" and "OFF"
indications. The circuit breaker dollies shall be of trip free pattern to prevent closing the
breaker on a faculty current. Tightening torque at terminals shall be not less than 2.5 Nm.
losses should not be more than as specified in IEC 898-1995. The MCB contact shall be silver
nickel and silver graphite alloy and tip coated with silver. Proper arc chutes shall be
provided to quench the arc immediately. MCB's shall be provided with magnetic fluid
plunger relay 3 as for over current and short circuit protection. The over load or short
circuit devices shall have a common trip bar in the case of DP and TPN miniature circuit
breakers. All the MCB's shall be tested and certified as per Indian Standard, prior to
For protection of electric circuits with equipment that does not cause surge current (i.e.
lighting and socket outlet circuits)’B’ curve MCB to be used in which magnetic releases
operates between 3 and 5 In.
For protection of electric circuits with equipment that cause surge current (i.e. inductive
and motor circuits) ’C’ curve MCB to be used in which magnetic releases operates between
5 and 10 In. For protection of electric circuits with equipment that cause surge current (i.e.
transformer, heavy start motors circuits) ’D’ curve MCB to be used in which magnetic
releases operates between 10 and 15 In. Isolators shall confirm to IS 13947-3 and IEC
Signature of the Tenderer Addl. Chief Engineer
Name (Electrical)
Company’s seal AMC
Section – 2 LT CABLING AND TERMINATION
The scope consists of Supply, laying, testing and commissioning of L.T. XLPE Cable and its
AS PER SCHEDULE OF INDIAN STANDARDS; ATTACHED IN THE DOCUMENT
A) LV POWER CABLES will be 1100 Volts grade single / multicore standard aluminum
conductor extruded XPLE insulated with extruded PVC inner sheath outer sheath made of
FRLS PVC compound conforming to IS-7098 part-1. Single core will be used for DC
application. Cables in buried insulation shall be armoured type. Armoured cable should be
provided with galvanized steel wire or strip armouring.
B) Control cables will be 1100 Volts grade multicore minimum 2.5 sqmm cross section
standard copper conductor minimum 7 strands PVC insulated inner extruded sheathed and
other sheath made of extruded FRLS PVC compound conforming to IS-1554 part-1. Cables in
buried insulation shall be armoured type.
C) All cables shall be new without any kind or visible damage. The manufacturers name,
insulating material, conductor size and voltage class shall be marked on the surface of the
cable at every 600 mm centres.
2.4 Cable joints and termination:
A) Connectors :
Cable terminations shall be made with copper/Aluminium Heavy duty long neck copper
crimping lugs only crimped type solder-less lugs for all aluminium cables and stud type
terminals. For copper cables copper crimped solder-less lugs shall be used. Crimping shall
be done with the help of hydraulically operated crimping tool. All cable lugs should be long
neck type only.
B) Cable Glands :
Cable glands shall be of heavy duty brass compression / whether proof type as specified.
Generally single compression type cable glands shall be used for indoor protected locations
and double compression type shall be used for outdoor locations. Glands for classified
hazardous areas shall be CMRI approved.
Ferrules shall be of self sticking type and shall be employed to designate the various cores
of the control cable by the terminal numbers to which the cores are connected, for ease in
identification and maintenance.
D) Cable joints :
Kit type joint shall be done and filled with
Signature of the Tenderer Addl.Chief Engineer
Name (Electrical)
Company’s seal AMC
Section-3 INTERNAL WIRING
The scope covers supply, laying, testing and commissioning of wiring in rigid PVC pipes,
Switches, Sockets and accessories.
3.2 Standards :
AS PER SCHEDULE OF INDIAN STANDARDS, ATTACHED IN THE DOCUMENT
3.3 Rigid and Flexible conduits:
A) All conduits shall be rigid PVC having minimum wall thickness of medium gauge 1.6 to
approved by F.I.A. & I.S.I. All rigid pipe and its accessories shall be of suitable material
complying with IS:3419-1989 and IS :9537 (Part 5) 2000 for flexible conduits.
The conduits shall be circular in cross-section and designated by their nominal outside
diameter. Minimum thickness of walls shall be as follows:
a) Up to 38 mm. diameter - minimum 1.8 mm. wall thickness.
b) Above 40 mm. diameter - minimum 2.2 mm. wall thickness.
The maximum number of PVC insulated copper conductor cables of 650/1100V grade
confirming to IS:694-1990 that can be drawn in one conduit of various sizes shall be as
B) Flexible conduits shall be formed from a continuous length of spirally wound interlocked
steel strip with a fused zinc coating on both sides. The conduit shall be terminated in brass
3.4 Accessories :
A) PVC conduit fittings such as bends, elbows, reducers, chase nipples, split couplings, plugs
etc. shall be specifically designed and manufactured for their particular application. All
conduit fittings shall conform to IS:2667-1964 and IS:3857-1966. All fitting associated with
galvanized conduit shall also be galvanized.
A) All wires shall be single core multi-strand/ flexible copper or single strand Copper FRLS
type PVC insulated as per IS:694 and shall be 660 V\1100 V grade.
B) All wires shall be colour coded as follows :
Phase Colour of wire
R Red Y Yellow B Blue N Black Earth Green (insulated) Control (If any) Grey
All off wires Same as Phase wire
C) Both end of wires should be terminated with adequate size copper crimping type lugs
and ferrules as per instructions of engineer in charge.
3.6 Additional requirements
3.6.1 Making Chase
The chase in the wall shall be neatly made and of ample dimensions to permit the conduit
to be fixed in the manner desired. Chase shall be done with machine cutter only. In the case
of building under construction, the conduits shall be buried in the wall before plastering
and shall be finished neatly after erection of conduit. In case of exposed brick/ RCC work,
special care shall be taken to fix the conduit and accessories in positionalong with the
3.6.2 Fixing conduits in chase
The conduit pipe shall be fixed by means of staples, J-hooks, or by means of saddler, not
more than 60 cm apart or by any other approved means of fixing. All threaded joints of
conduit pipes shall be treated with some approved preservative compound to secure
protection against rust.
3.6.3 Fixing conduits in RCC work (slab / wall / floor etc)
The conduit pipes shall be laid in position and fixed to the steel reinforcement bars by steel
binding wires before the concreting is done. The conduit pipes shall be fixed firmly to the
steel reinforcement bars to avoid their dislocation during pouring of cement concrete and
subsequent tamping of the same. Fixing of standard bends or elbows shallbe avoided as far
as practicable, and all curves shall be maintained by bending the conduit pipe itself with a
long radius, which will permit easy drawing in of conductors.
Location of inspection/ junction boxes in RCC work should be identified by suitable means
to avoid unnecessary chipping of the RCC slab subsequently to locate these boxes.
At either side of the bends, saddles/staples shall be fixed at a distance of 15 cm from the
centre of the bends.
A protective earth conductor shall be drawn inside the conduit in all distribution circuits to
proved for earthing of non current carrying metallic parts of the entire installation. These
shall be terminated on the earth terminal in the switch boxes, and/or earth terminal blocks
at the distribution boards. Gas or water pipes shall not be used as protective conductors
(earth medium). Every sub main will be earth continuity conductor to run along with sub
main wiring. Every circuit will have its earth continuity conductor to run along with circuit
wiring. In case of 3 phase sub main wiring two earth continuity conductor shall be provided.
Signature of the Tenderer Addl.Chief Engineer
Name (Electrical)
Company’s seal AMC
Section-4 EARTHING
4.1 Scope of Work:
The scope of work shall cover supply, laying, installation, connecting, testing and
commissioning of:
1.1.1 chemical or Electrode type Earthing station.
1.1.2 copper strips from earthing station to equi-potential bar.
1.1.3 copper strips/ wires from equi-potential bar to lay feeder mains and circuit to connect
power panels, DBs, switchboards etc.
1.1.4 Bonding of Non-current carrying parts, and metallic parts of the electrical installation.
1.1.5 Provide inter connection between all earth pits of same type.
4.2.1 The following standards and rules shall be applicable:
1) IS: 3043 - 1966 Code of practice for Earthing.
2) Indian Electricity Act and Rules
4.2.2 All codes and standards mean the latest. Where not specified otherwise the
installation shall generally follow the Indian Standard Code of Practice or the British
Standard Codes of Practice in absence of Indian standard.
All the non-current carrying metal parts of the electrical installation and mechanical
equipments shall be earthed properly. The metal conduits, trucking, cables armoured and
sheath, electric panels boards, lighting fixtures, ceiling and exhaust fan and all other parts
made of metal shall be bonded together and connected by means of specified earthing
An earth continuity conductor shall be installed with all the feeders and circuits and shall be
connected from the earth bar of the panel boards, to the conduit system, earth stud of the
switch box, lighting fixture, earth pin of the socket outlets and to any metallic wall plates
used. All the enclosures of motors shall be also connected to the earthing system.
4.4 TYPE OF EARTHING STATION
4.4.1 ELECTRODE / CHEMICAL TYPE EARTHING STATIONS:
4.4.1.1 The substation earthing and equipment earthing shall be with T-39 OR & T-19 as per
earthing scheduled in BOQ & Drawing.
4.4.1.2 The earthing station shall be as shown on the drawing.
4.4.1.3 The earth resistance shall be maintained with suitable soil treatment as shown in
4.4.1.4 The resistance of each earth station should not exceed the limit specified in IS:
4.4.1.5 The earthing grid and the earthing conductors shall be of copper strip of size as
mentioned on the drawing.
4.4.1.6 The block masonry chamber with Cast Iron hinged cover shall be provided for
the termination block as shown in the drawing.
4.4.1.7 The hardware and other consumable for earthing installation shall be of
copper/brass, as
per details shown in the drawing.
4.5 INSTALLATION AND CONNECTION:
4.5.1 The plate \ pipe electrode, as far as practicable, shall be buried below permanent
moisture level but in no case not less than 2.5 M below finished ground level.
4.5.2 The plate \pipe electrode shall be kept clear of the building foundation and in no case,
it shall be nearer by less than 2 M from outer face of the respective building wall \ column.
4.5.3 The plate electrode shall be installed vertically and shall be surrounded with 150 mm.
thick layers of Charcoal dust and Salt mixture.
4.5.4 G.I. pipe for watering shall run from top edge of the plate \ pipe electrode to the mid
level of block masonry chamber.
4.5.5 Top of the pipe shall be provided with G.I. funnel and screen for watering the earth \
ground through the pipe.
4.5.6 The funnel with screen over the G.I. pipe for watering to the earth shall be housed in a
block masonry chamber as shown in the drawing.
4.5.7 The masonry chamber shall be provided with a Cast Iron hinged cover resting over the
Cast Iron frame which shall be embedded in the block masonry.
4.5.8 Construction of the earthing station shall in general be as shown in the drawing and
shall conform to the requirement on earth electrodes mentioned in the latest edition of
Indian Standard IS : 3043, Code of Practice for Earthing Installation.
4.5 9 The earth conductors ( Strips / Wires copper/ Hot dip G.I.) inside the building shall
properly be clamped / supported on the wall with Galvanized Iron clamps and Mild Steel
Zinc Passivated screws \ bolts. The conductors outside the building shall be laid at lNORTH
600 mm. below the finished ground level.
4.5.10 The earth conductors shall either terminate on earthing socket provided on the
equipment or shall be fastened to the foundation bolt and / or on frames of the equipment.
The earthing connection to equipment body shall be done after removing paint and other
oily substances from the body and then properly be finished.
4.5.11 Over lapping of earth conductors during straight through in joints, where required,
shall be of minimum 75mm. long.
4.5.12 The earth conductors shall be in one length between the earthing grid and the
equipment to be earthed.
4.6 EARTH LEADS AND CONNECTIONS:
4.6 1 Earth lead shall be bare copper or galvanized steel as specified with sizes shown on
drawings. Copper lead shall have a phosphor content of not over 0.15 %. Galvanized steel
buried in the ground shall be protected with bitumen and Hessian wrap or polytene faced
Hessian and bitumen coating. At road crossing necessary Hume pipes shall be laid. Earth
lead run on surface of wall or ceiling shall be fixed on saddles so that strip is at lNORTH
mm away from the wall surface.
4.6.2 The complete earthing system shall be mechanically and electrically bonded to
provide an independent return path to the earth source.
Signature of the Tenderer Addl. Chief Engineer
Name (Electrical)
Company’s seal AMC
SECTION B.1.A:- MAN POWER / STAFF FOR THE CONTRACT
The contractor shall provide qualified and experienced personnel with his personnel
identity card and dress necessary as mentioned below for Maintenance Rate contract
for Electrical installations of various community halls and Party Plots in NORTH Zone of
AMC. Smoothly/safely and efficiently on a requirement basis or as per instruction of
engineer in charge.
ANNEXURE-I :- REQUIRED MINIMUM QUALIFICATION OF PERSONNEL
S. Designation Qualification Experience
N. ( Minimum) ( Minimum)
1 Electrician Minimum 2nd class ITI Having experience in maintenance
Electrician work for Electrical installations.
2 Wireman Minimum 2nd class ITI Having experience for Electrical
Helper Wireman System Maintenance Work.
Signature of the Tenderer Addl. Chief Engineer
Name (Electrical)
Company’s seal AMC
B.2 APPLICABLE STANDARDS
IS No. Description
IS: 3043-198 : Code of practice for earthing.
IS: 13947-Part I : General requirements for switch gear and -1993 control gear for voltage
not exceeding 1000 Volts.
IS: 11353-1985 : Marking and arrangement of switch gear bus bars main connectors and
auxiliary wiring..
IS: 8828-1995 : Miniature Circuit Breaker.
IS: 1554-Part I : PVC insulated electric cables-1988 Heavy duty.
IS: 3961-Part II & IV : Recommended current rating-1967 for cables.
IS: 8130-1984 : Copper conductor in insulated cables and cores.
IS: 8130-1984 : Conductor for insulated electric cables
IS: 5831-1984 : PVC insulation and sheath of electric cables.
IS: 8130-1984 : Aluminum conductor for insulated cables.
IS: 11955-1987 : Recommended current rating for Cable.
IS: 732-1989 : Code of practice for electrical wiring installation system Voltage not
exceeding 650 Volts.
IS: 1646-1997 : Code of practice for fire safety of Buildings (general) electrical installation.
IS: 7098 (Part I, II, III) : XLPE armoured Cables up to -1988 1000V.
NOTE: All codes and standards means the latest where not specified otherwise the
installation shall generally follow the Indian Standard codes of practice or relevant British
Standard Codes of Practice in the absence of corresponding Indian Standards.
a. Indian Electricity Act of 1910 and rules issued there under revised up to date.
b. Regulations for electrical equipment in building issued by The Bombay Regional Council
of insurance Association of India.
Signature of the Tenderer Addl. Chief Engineer
Name (Electrical)
Company’s seal AMC
B.3 LIST OF APPROVED MAKE
S.N. NAME OF EQUIPMENT / MATERIAL APPROVED MAKE
1 RIGID PVC CONDUIT & ACCESSORIES PRECISION / NIHIR / AKG/ BEC/ VRAJ
2 UPVC CABLE TRUNKING / CMS PRECISION / MK / NIHIR / LEGRAND/VRAJ
3 FLEXIBLE CU. WIRES-FR/FRLS GRADE FINOLEX / POLYCAB / RRKABLE /
HAVELL’S / DARSHAN PLUS
4 ELECTRODE TYPE EARTHING ASHLOK / MAP / RAPID/AXIS
6 MCB,MCCB, RCCB / ELCB, MCB ISOLATOR SIEMENS / LEGRAND / HAVELL’S /
7 CABLE GLAND COMET(COSMOS) / DOWELLS / HMI /
JAINSON /SIEMENS
8 CABLE LUGS DOWELLS / JAINSON / HEX
9 L.T CABLES FINOLEX / POLYCAB / HAVELL’S / RR
10 CEILING / EXHAUST FAN CROMPTON / ORIENT / HAVELLS/USHA
11 LIGHT FIXTURES AND TUBE ROADS CROMPTON / PHILIPS / BAJAJ / WIPRO
12 MODULAR SWITCHES, SOCKETS & LEGRAND / CRABTREE /ANCHOR / VINAY
Signature of the Tenderer Addl. Chief Engineer
Name (Electrical)
Company’s seal AMC