Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹95.0 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹98.6 L+₹3.7 L (3.85%)Rejected-Finance 65 RANJEET NAGAR NEAR SAI HOSPITAL AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹99.8 L+₹4.9 L (5.13%)Rejected-Finance 121 MODEL TOWN AMBALA CITY HRY | AMBALA CITY | AMBALA | HARYANA | 134003 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹1.1 Cr+₹12.4 L (13.0%)Rejected-Finance 231 JAGGI GARDEN BALDEV NAGAR AMBALA CITY 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L4 | Rejected-Finance Not lowest |
Tender Value
₹87 L
EMD Value
₹1.6 L
Closing Date
8 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF AMBALA
HQ CWE AF AMBALA Ambala cantt 133001
PROVISION OF OTM ACCOMODATION FOR PAR AT TECH AREA UNDER GE (AF) AMBALA
2021_MES_495213_2
CWE/AF AMB/AMB-36/2021-22
Open Tender
Construction Works
Lump-sum
140 days
Ambala cantt
For enlisted in MES Class C and category a i and for unenlisted refer NIT
7 documents required · 7 mandatory
₹1,000
GE AF AMBALA
₹1.6 L
Yes
23 Mar 2022
9 Feb 2022
10 Mar 2022
9 Feb 2022
8 Mar 2022
24 Feb 2022
9 Feb 2022 - 20 Feb 2022
60 days
Amount
Schedule 'A' Section-I to Section-IX (BOQ Item No 1.01 to 1.09 here-in-after) (PREPRICED BY MES). These schedules are prepriced by MES and Prepriced rates indicated under column-6. Bidders to quote there rates under Column-7 only .
Schedule 'A' Section-I (Building works)
Schedule 'A' Section-II (Internal Water supply works)
Schedule 'A' Section-III (Internal Electrification works)
Schedule 'A' Section-IV (Road works)
Schedule 'A' Section-V (Pedestal works)
Schedule 'A' Section-VI (Hardstanding works)
Schedule 'A' Section-VII (Sewage Disposal works)
Schedule 'A' Section-VIII (External Electrification works)
Schedule 'A' Section-IX (External Water supply works)
Schedule 'A' Section-X (Miscellenous item of works) (Item No 2.01 to 2.49 here-in-after) (to be priced by bidders). Bidders to quote there rates under Column-7 only .
S&F LED light fittings 45watts, input 110 volts to 280 volts, life > 50000 Hrs, operating temp 1 degree to 50 degree, as per IP 65 , luminaries comprising of rectangular shape pressure Die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 45watt & rated lumens of min 5000 lumens with 120 degree view angle , the driver must be constant current type having THD <10% and power factor >0.95 with short circuit protection , open circuit protection, reverse circuit protection, high voltage protection, protection against 10 KV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light control and comply to IEC60598/IS10322 with and including GI pipe bracket 40 mm dia light grade of length 1.5 meter bend to shape and suitable size of clamps nuts bolts , washer , fastner duly painted with aluminium paint over one coat of redoxide primer and necessary connection with multistranded copper conductor cable 3 core 1.0sqmm from ceiling rose to fitting drawn thoroughout existing GI bracket complete all as specified and directed
S&F sheet metal enclosure for 4 way MCCB incomer + 12 modules outgoings, vertical triple pole and neutral loadline distrubution board, IP 43, double door type, confirming to IS 8623-III, 160 Amp rated bus bar blanking plates flushed inside the wall including 01 No. incomer MCCB 100 Amp, 415 Volts, 16 KA, 4 pole, 3 phase, with adjustable thermal & fixed magnetic setting and making good the disturbed surfaces complete all as specified and directed.
S&F MCB, SPN, 40 Amp, 'C' curve, 10 kA capacity, 240 volts complete all as specified and directed.
S&F MCB, SP, 63 Amp, 'C' curve, 10 kA capacity, 240 volts complete all as specified and directed.
S&F pedestal fan, AC, single phase 230/240 volt, 450mm sweep including fixing arrangement with suitable size of fastner complete all as specified and directed
M & L for 200mm thick (compacted thickness) in two layers of 100 mm thick each GSBC (Granular Sub Base Concrete) grading I as per table 400-I MORTH specifications and mixed with 35% coarse graded crushed stone aggregates by providng close graded material mixing by any means as per site conditions, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory roller 8 tonne to 10 tonne capacity and maintaining the required density, grading and mositure content as per MORTH specifications complate all as specified and directed.
Material & labour 150 mm thick (compacted thickness) Wet mix macadam (WMM) in two layers(each layer of 75mm thick) with coarse aggregate (lime stone, sand stone, flint or quartzite) of grading 2 (63 to 40mm size ) or of grading 3 (50 mm to 20mm) specification as per clause 406 and as per table 400-13 of yellow book of MORT&H including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site for all leads & lifts, to be laid using mechanical paver, spread watered,rolled & consolidated to required gradient and camber with vibratory type power roller 8 tonne to 12 tonne capacity to achieve the desired density complete all as specified and directed.
Construction of Soakage well 1.2mtr dia & 3.0mtr deep complete all as specified & shown on drawings bearing No. CEJZ/STD-301/90, sheet 1/4 to 4/4.
Construction of Septic tank, 10 users, single compartment complete all as specified & shown on drawings bearing No. CEJZ/STD-263/90, sheet 1/9 to 9/9.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed
M&L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed
Supply & spreading 40 mm graded crushed stone aggregate in layer not exceeding 150mm thick each layer around the transformer/LT Panel at sub station complete all as specified and directed.
Supply & spreading/filling 20mm graded stone aggrgate in layer not exceeding 150mm each layer complete all as specified and directed.
S&F cable jointing kit for 1100 volt earthed grade, outdoor, end termination, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 sqmm complete all as specified and directed.
S&F cable jointing kit for 1100 volt earthed grade, outdoor, end termination, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 sqmm complete all as specified and directed.
S&F cable jointing kit for 1100 volt earthed grade, outdoor, end termination, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm complete all as specified and directed.
S&F cable jointing kit for 1100 volt earthed grade, outdoor, end termination, heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 16 sqmm complete all as specified and directed.
Material and labour for Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and directed.
Supply and laying old size, common burnt clay, sub class 'B' bricks, designation 75, laid flat for protection of cable , adjacent to each other, perpendicular to central axis of cable complete all as specified and directed.
M&L GI pipe 80 mm bore , light grade as in trenches, under road,under floor, fixed to wall with fixing arrangement with suitable size of MS clamps made from 40x3 mm size flat iron including nuts,bolts & washers or along the pole with fixing arrangement etc for cable protection complete all as specified and directed .
M&L GI pipe 50 mm bore , light grade as in trenches, under road,under floor, fixed to wall with fixing arrangement with suitable size of MS clamps made from 40x3 mm size flat iron including nuts,bolts & washers or along the pole with fixing arrangement etc for cable protection complete all as specified and directed .
M&L for boring upto 50 mm dia under road / path / hardstanding to pass the HT/LT cables in soft /losse soil with complete arrangement of T&P complete all as specified and directed.
M&L for boring upto 80 mm dia under road / path / hardstanding to pass the HT/LT cables in soft /losse soil with complete arrangement of T&P complete all as specified and directed.
Supply, installation, testing & commissioning, floor mounted, cubical type, CPRI approved, LT panel, outdoor type, factory made, IP -54 class protection, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 40mm x 40mm x 6 mm angle iron frame and 3.15mm thick powder coated CRCA sheet, side covers with front and back hinged doors with proper locking arrangement, width of panel not less than 75cm, rubber gasket on front and back to make it dust and vermin proof having seprate compartment for each MCCB including 500 Amp & 300 Amp(neutral) rated aluminium busbar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of copper cable not less than 4.0sqmm alongwith provision of suitable power factor capacitors, complete with the following accessories all as specified and directed:- (a) Incoming (i) MCCB 320 Amp, 415 Volts, 36KA, 4 pole - 01 No. (ii) Multifunctional energy meter in 96mm x 96mm flush mounted case with six direct access keys & backlit LCD display, accuracy class 1.0, 5A CT input LV networks AC auxilary supply. Measurement V, I, In, P,Q, S, PF, F, Ea, Er, & Es, THD for V & I - 01 Set (iii) CT of ratio 100/50/5 Amp, class-1, VA burden 15 - 01 set of three (iv) Indicating lamp - 01 set of three (b) Outgoing (i) MCCB, 160 Amp, 415 Volts, 25 KA, 4 pole - 03 Nos.(02 Nos for sub panel & 01 No. spare) (ii) MCCB, 125 Amp, 415 Volts, 25 KA, 4 pole - 01 No. (iii) Spare compartment - 02 Nos.
Supply, installation, testing & commissioning, floor mounted, cubical type, CPRI approved, LT panel, indoor type, factory made, IP -54 class protection, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 40mm x 40mm x 6 mm angle iron frame and 2.0mm thick powder coated CRCA sheet, side covers with front and back hinged doors with proper locking arrangement, width of panel not less than 75cm, rubber gasket on front and back to make it dust and vermin proof having seprate compartment for each MCCB including 300 Amp & 160 Amp(neutral) rated aluminium busbar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of copper cable not less than 4.0sqmm complete with the following accessories all as specified and directed:- (a) Incoming (i) MCCB 160 Amp, 415 Volts, 25KA, 4 pole - 01 No. (ii) Multifunctional energy meter in 96mm x 96mm flush mounted case with six direct access keys & backlit LCD display, accuracy class 1.0, 5A CT input LV networks AC auxilary supply. Measurement V, I, In, P,Q, S, PF, F, Ea, Er, & Es, THD for V & I - 01 Set (iii) CT of ratio 400/100/5 Amp, class-1, VA burden 15 - 01 set of three (iv) Indicating lamp - 01 set of three (b) Outgoing (i) MCCB, 100 Amp, 415 Volts, 16 KA, 4 pole - 03 Nos.(02 Nos for sub panel & 01 No. spare) (ii) MCB, TPN 32 Amp, 415 Volts, 10 KA - 03 Nos. (iii) Spare compartment - 02 Nos.
Supply, installation, testing & commissioning, floor mounted, cubical type, CPRI approved, LT panel, indoor type, factory made, IP -54 class protection, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 40mm x 40mm x 6 mm angle iron frame and 2.0mm thick powder coated CRCA sheet, side covers with front and back hinged doors with proper locking arrangement, width of panel not less than 75cm, rubber gasket on front and back to make it dust and vermin proof having seprate compartment for each MCCB including 250 Amp & 160 Amp(neutral) rated aluminium busbar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of copper cable not less than 4.0sqmm complete with the following accessories all as specified and directed:- (a) Incoming (i) MCCB 160 Amp, 415 Volts, 25KA, 4 pole - 01 No. (ii) CT of ratio 400/100/5 Amp, class-1, VA burden 15 - 01 set of three (iii) Indicating lamp - 01 set of three (b) Outgoing (i) MCB, TPN, 32 Amp, 415 Volts, 10 KA - 02 Nos.(01 No working & 01 No. spare) (ii) MCB, SPN, 20 Amp, 240 Volts, 10 KA - 10 Nos.(09 Nos working & 01 No. spare) (iii) MCB, SPN, 16 Amp, 240 Volts, 10 KA - 04 Nos.(02 Nos working & 02 Nos. spare) (iv) MCB, SPN, 5-16 Amp, 240 Volts, 10 KA - 04 Nos.(02 Nos working & 02 Nos. spare)
Supply, installation, testing & commissioning, floor mounted, cubical type, CPRI approved, LT panel, indoor type, factory made, IP -54 class protection, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 40mm x 40mm x 6 mm angle iron frame and 2.0mm thick powder coated CRCA sheet, side covers with front and back hinged doors with proper locking arrangement, width of panel not less than 75cm, rubber gasket on front and back to make it dust and vermin proof having seprate compartment for each MCCB including 160 Amp & 100 Amp(neutral) rated aluminium busbar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of copper cable not less than 4.0sqmm complete with the following accessories all as specified and directed:- (a) Incoming (i) MCCB 63 Amp, 415 Volts, 25KA, 4 pole - 01 No. (ii) CT of ratio 400/100/5 Amp, class-1, VA burden 15 - 01 set of three (iii) Indicating lamp - 01 set of three (b) Outgoing (i) MCB, TPN, 10-40 Amp, 415 Volts, 10 KA - 04 Nos.(03 No working & 01 No. spare) (ii) MCB, SPN, 6-32 Amp, 240 Volts, 10 KA - 03 Nos.(02 Nos working & 01 No. spare)
Supply, installation, testing & commissioning, floor mounted, cubical type, CPRI approved, LT panel, indoor type, factory made, IP -54 class protection, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 40mm x 40mm x 6 mm angle iron frame and 2.0mm thick powder coated CRCA sheet, side covers with front and back hinged doors with proper locking arrangement, width of panel not less than 75cm, rubber gasket on front and back to make it dust and vermin proof having seprate compartment for each MCCB including 200 Amp & 160 Amp(neutral) rated aluminium busbar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and wiring with suitable size of copper cable not less than 4.0sqmm complete with the following accessories all as specified and directed:- (a) Incoming (i) MCCB 100 Amp, 415 Volts, 25KA, 4 pole - 01 No. (ii) CT of ratio 400/100/5 Amp, class-1, VA burden 15 - 01 set of three (iii) Indicating lamp - 01 set of three (b) Outgoing (i) MCB, TPN, 20-32 Amp, 415 Volts, 10 KA - 02 Nos.(01 No working & 01 No. spare) (ii) MCB, SPN, 20-32 Amp, 240 Volts, 10 KA - 06 Nos.(04 Nos working & 02 Nos. spare) (iii) MCB, SPN, 6-10 Amp, 240 Volts, 10 KA - 02 Nos.(01 No working & 01 No. spare)
Note for BOQ item No. 2.25 to 2.29 : (i) The cost of floor mounting of Panel as directed by GE shall deemed to be included in quoted rates. (ii) The MS angle iron frame shall be duly painted with two coat of synthetic enamel paint over a coat of redoxide primer and shall deemed to be included in quoted rates. (iii) Layout diagram of LT panel shall be submitted by contractor through GE for approval of Accepting officer before placing order to manufacturer and panel shall be brought at site as per approved drawing.
S&F LED light fittings 90watts, input 110 volts to 280 volts, life > 50000 Hrs, operating temp 1 degree to 50 degree, as per IP 65 , luminaries comprising of rectangular shape pressure Die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 90watt & rated lumens of min 9900 lumens with 120 degree view angle , the driver must be constant current type having THD <10% and power factor >0.95 with short circuit protection , open circuit protection, reverse circuit protection, high voltage protection, protection against 10 KV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light control and comply to IEC60598/IS10322 with and including GI pipe bracket 40 mm dia light grade of length 1.5 meter bend to shape and suitable size of clamps nuts bolts , washer , fastner duly painted with aluminium paint over one coat of redoxide primer and necessary connectionwith complete all as specified and directed
S & F outdoor type SMC junction box of size 170mm X 170mm X 105mm one piece moulded SMC door hinged fixed base with hinged right or left side and fixed to the foundation pole with suitable fixing arrangement busbar with single electrolytic aluminim for both phase neutal supported on FRP insulator and cut out complete fixed on the pole with suitable inlet and outlet, provision for cable connection, MCB single pole 6 Amp capcity for controling the pole light, including connection with 1.0sqmm two core PVC insulated copper cable to be drawn through pole for suitable length from SMC box to fitting complete as specified and directed.
S&F PVC copper conductor cable 3 x 1.5sqmm in and including 20mm bore PVC conduit medium grade on pole for security light fitting complete all as specified and directed
Supplying, installation, testing and commissioning of advance maintenance free environment freindly ring earthing system of dia 350mm & depth 11 feet chemical earthing system consisting of 3 Nos. of Copper Bonded Earth Rod of 10 feet length, 17.2 mm dia made of high tensile low carbon steel circular rods, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness-250 microns) with terminals to connect incoming stip in the ground with 3 bags (60 Kg per earthing pit) of environment friendly backfil compound carbon base, Graphite blend and portland cement mixed (approved by Engr-in-charge) resistivity below 0.15 Ohm meter for high currect (for electrical system) as per manufaccturing instructions for each 150mm x 25mm x 6mm copper bar with 4 hole shall be exothermically welded on top to copper bounded rod to make terminal laid in minimum 200mm dia bore. Making 3 Nos holes of complete earthing set in which each hole should be provided with 100 Kg Bentonite in outer 150mm part of the hole and inner 200mm dia fill with back fill material. Manufacturer name shall be embossed on rod. 25mm x 3mm copper shall be burried 20cm below the ground used to interconnected the earths and to make the ring. The earth pit cover polypropylene (250mm top x 340mm bottom x 250mm height) of 2 Kg weight shall be included in the scope of work including PCC (1:2:4) base block of fitting of pit cover complete all as specified & directed. Notes : The testing of earth resistance will be done in presence of MES rep and user and results will be recorded in register duly signed by user and Engg-in-charge. Contractor will arrange all necessary T&P for testing of earth and contractor will be fully responsible for testing of earth resistance, maintaining the record and maintain the earth value with in permissible limit. In case desired resistance(less than 1 ohm) not obtained during testing, the earthing shall be re-done without any cost to the Govt.
Cutting the existing DI/CI pipe line for fixing tee / bend etc of pipe 80/50 mm bore complete all as specified and directed
M&L construction of brick masonary valve pit, internal size 45 cm x 45 cm, 45 cm deep (depth to be reckoned from top of the PCC in foundation to the top of MS cover), 150 mm thick PCC 1:4:8, type D-2 as in foundation & 150 mm thick PCC 1:2:4 type B-2 as in coping with & including necessary form work, brick work in cement mortar 1:4 using old size sub class burnt clay bricks, 15mm thick internal plaster in cement mortar 1:4 even & smooth, Pit cover shall be of MS sheet 3.0 mm thick with complete locking & hinging arrangement and painting with two coats of black synthetic enamel paint over one coat of red oxide primer complete all as shown on drawing and directed. Note:- (i) The Excavation & eathwork shall be in any type of soil. The removal of surplus soil shall be to a distance not exceeding 50mtr. (ii) The valve pit shall be constructed as per drg No CE AF/STD-28/94 dated 01-Feb-1994, Sheet No 1/2 & 2/2. The drawings may be referred from office of GE. (iii) Cost shall be inclusive of all items of work required for the execution (as shown on drawing) and entire completion of this item and noting extra shall be paid seprately in any other item(s).
Supply, fabrication, installation & testing of power manager made of galvanised iron sheet 1.6 mm thick, powder coated suitable size duly housed for following accessories complete with internal wiring of copper FRLS cable of suitable rating complete all as specified and directed:- (i) Socket outlet 2 in 1, 3 pin 5 Amp & 15 Amp flush type multipurpose 240 volts with switch piano flush type single pole, one way 15 Amp - 05 Nos. (ii) MCB SPN 40 Amps 'C' Curve, 10 KA for controling above switch and sockets - 01 No.
Supply, fabrication, installation & testing of power manager made of galvanised iron sheet 1.6 mm thick, powder coated suitable size duly housed for following accessories complete with internal wiring of copper FRLS cable of suitable rating complete all as specified and directed:- (i) Socket outlet 2 in 1, 3 pin 5 Amp flush type, 240 volts with switch piano flush type single pole, one way 6 Amp - 05 Nos. (ii) MCB SPN 10 Amp 'C' Curve, 10 KA for controling above switch and sockets - 01 No.
Supplying, laying & fixing copper conductor FRLS PVC insulated unsheathed cable 4.0 sqmm, 3 core, single phase, neutral with earth wire complete all as specified and directed.
Supplying, laying & fixing copper conductor FRLS PVC insulated unsheathed cable 6.0 sqmm, 3 core, single phase, neutral with earth wire complete all as specified and directed.
Supplying, laying & fixing copper conductor FRLS PVC insulated unsheathed cable 10.0 sqmm, 3 core, single phase, neutral with earth wire complete all as specified and directed.
Supply, installation & testing of dimmer light 500 watt of different colour controlled by control switch 240 volt single phase complete all as specified and directed.
M&L perforated stainless steeel (heavy duty) cable tray of size 30 cm breath and 15 cm height including necessary fixing arrangment with wall/ceiling complete all as specified and directed.
M&L perforated stainless steeel (heavy duty) cable tray of size 60 cm breath and 15 cm height including necessary fixing arrangment with wall/ceiling complete all as specified and directed.
Supply and fixing retrofit LED bulb 9 watts, pin type, colour white light complete all as specified and directed.
S&F galvanized iron tubing 100mm bore, medium grade with all fittings and finial taper plug cut in length of 10 feet & fixed in PCC (1:3:6 type C1) complete all as directed for mounting of security light at height of 8 feet from ground level including fixing accessories (such as nut, bolt, washer, clamp etc.) complete all as specified and directed. Note: Neccessary earthwork, PCC & formwork if any deemed to be included in quoted rates.
M&L earthing complete with galvanized steel earth plate electrode 60cm X 60cm X 6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level surrounded from all sides by 15cm thick packed layer of Charcoal dust & common salt filled in alternate layers and electrode connected to GI earth lead strip 32 mm x 6 mm upto 7.5mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly & watering pipe medium grade GI 20 mm bore including protection pipe GI light grade 40mm bore, including wire mesh, funnel, lugs, salt, charcoal dust, excavation in soft/losse soil, returning filling & removal of surplus soil upto 50mtr, pit chamber shall be of PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates and pit cover slab 80mm thick shall be of Precast RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates reinforced with XPM weighing not less than 4Kg/sqm including necessary form work complete all as shown in electrical plate No 3 of SSR part-I, including testing on completion at site complete all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 60cm X 60cm X 6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level surrounded from all sides by 15cm thick packed layer of Charcoal dust & common salt filled in alternate layers and electrode connected to GI earth lead wire 4.0mm dia upto 7.5mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly & watering pipe medium grade GI 20 mm bore including protection pipe GI light grade 15mm bore, including wire mesh, funnel, lugs, salt, charcoal dust, excavation in soft/losse soil, returning filling & removal of surplus soil upto 50mtr, pit chamber shall be of PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates and pit cover slab 80mm thick shall be of Precast RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates reinforced with XPM weighing not less than 4Kg/sqm including necessary form work complete all as shown in electrical plate No 3 of SSR part-I, including testing on completion at site complete all as specified and directed.
Note for BOQ item No. 2.47 to 2.48 : (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing if the desired earth resistance is not obtained, earthing will be generated at no extra cost , till the desired earth resistance is obtained. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
BAL SINGH & SONS
Laxmi Builders
Bairagi Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .