Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹27.9 L+₹1.4 L (5.47%)Rejected-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹28.6 L+₹2.2 L (8.38%)Rejected-Finance | L3 | Rejected-Finance Rejected being | |
| 4 | L4₹32.4 L+₹6.0 L (22.6%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L4 | Rejected-Finance Rejected being | |
| 5 | L5₹32.5 L+₹6.0 L (22.9%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L5 | Rejected-Finance Rejected being |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
27 May 2024, 6:00 pmClosed
GE (N) AMBALA CANTT
GE (N) AMBALA CANTT
CA NO GE(N)AMB-11/2024-25 REWIRING OF INTERNAL ELECTRIFICATION INCLUDING CONNECTED ITEMS IN OFFR,S MD ACCN OF AREA-I AND OTHER AREA OF SECTOR B OF AGE E/M UNDER GE (N) AMBALA CANTT
2024_MES_648539_1
GE(N)/AMB-11/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE (N) AMBALA CANTT
As per tender documents
9 documents required · 9 mandatory
₹500
GE (N) AMBALA CANTT
₹88,000
Yes
22 Jul 2024
30 Mar 2024
29 May 2024
30 Mar 2024
27 May 2024
13 May 2024
30 Mar 2024 - 13 May 2024
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. for one light/fan/exhaust fan/bell point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description all as per serial item No.02 here-in-before but for One 3 pin, 6 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description all as per serial item No.02 here-in-before but for One 3 pin 6 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Description all as per serial item No.02 here-in-before but for one socket outlet 16 Amp with 2.50 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade, ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
Description all as per srl item No 02 here-in-before but for one socket outlet 16 Amp with 4.00 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 4.00 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of modular socket outlet 2/3 pin combined, 6 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of modular socket outlet 3/3 pin combined, (6pin), 6/16 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair electronic Fan regulator modular 100 watt, 1 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of modular bell push 6 Amp, 1 way, 1 module, 230 volts complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair calling bell ding dong 230 volt, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement LED lamp 9 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete all as specified and as directed by the Engineer-in-Charge.
Supply only in replacement LED lamp 12 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, indoor decorative LED tube light fitting box type 18/20 watt with electronic driver, opal diffuser, high efficient aluminium housing body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz including 18/20 Watt LED tube rod luminaries environment friendly, high efficient, T8 with aluminium extrusion heat sink and connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair LED batten fitting 10-12 watt, 2 feet, PVC housing with electronic driver including tube rod 10/12 watt cool/warm type industrial model complete, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, LED surface mounted bulk head luminaries 8-10 watt with min 800 lumen, industrial model, IP 65, PVC housing, surge protection including driver and LED lamp, etc. complete with all accessories, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, 9/12 watt LED light fitting wall mounting wooden fixture (sketch type) including LED lamp compact and energy efficient epoxy powder coated luminaire and connecting with copper conductor flexible cable from ceiling rose to connector of the light complete including removing unserviceable light fittings complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, LED Bldg Security Light Fittings of capacity 20 -25 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including electronic driver, service bracket of mild steel pipe 32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to MS pipe as required at site and two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work and making electrical connection, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, service bracket of mild steel pipe 25 mm bore medium grade of length 0.70 mtr fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts and washer and suitable reducer for connecting fitting to GI pipe as required at site including two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'B' curve, complete all as specified and as directed by the Engineer-in-Charge.
Supplying and fixing in repair of VTPN MCCB distribution board 4 way, fabricated out of thick high quality CRCA sheet. with 200 Amp rated bus bars, flush /surface mounting duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface complete all as specified and as directed by the Engineer-in-Charge. Note- The Distribution Board shall have following specification. (I) Distribution Board shall be totally enclosed, suitable for 240V/415V, having polyurethane(PU) foam gasket to ensure IP-54 degree of protection for indoor application as per IEC 61439-3:2012(Cl.10.3)/IEC 60529. (ii) Distribution Board shall be robust with tested for Impact resistance IK09 as per IEC 61439-3:2012(Cl.No.10.2.6) and shall be provided with pre fitted cement Guard. (iii) DB Door shall have detachable gland plates provided with proper knockout holes of 26mm/35mm diameter for insertion of cable/conduits. (iv) Distribution Boards shall be provided with wire set of copper along with the insulated fork type bus bars. (v) DB shall have reversible hinged doors and possibility to allow door opening from Left to Right or Right to Left for convenience on site. (vi) Contractor shall provide test reports of DB as per IEC 61439-3 from ERDA or NABL laboratory before incorporating in work.
Supplying and fixing in repair of TPN MCB distribution board 4 way, fabricated out of thick high quality CRCA sheet. with 200 Amp rated bus bars, flush /surface mounting duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface complete all as specified and as directed by the Engineer-in-Charge. Note- The Distribution Board shall have following specification. (I) Distribution Board shall be totally enclosed, suitable for 240V/415V, having polyurethane(PU) foam gasket to ensure IP-54 degree of protection for indoor application as per IEC 61439-3:2012(Cl.10.3)/IEC 60529. (ii) Distribution Board shall be robust with tested for Impact resistance IK09 as per IEC 61439-3:2012(Cl.No.10.2.6) and shall be provided with pre fitted cement Guard. (iii) DB Door shall have detachable gland plates provided with proper knockout holes of 26mm/35mm diameter for insertion of cable/conduits. (iv) Distribution Boards shall be provided with wire set of copper along with the insulated fork type bus bars. (v) DB shall have reversible hinged doors and possibility to allow door opening from Left to Right or Right to Left for convenience on site. (vi) Contractor shall provide test reports of DB as per IEC 61439-3 from ERDA or NABL laboratory before incorporating in work.
Supplying and fixing in repair Thermoplastics IP 65 MCB distribution board in accordance with IEC 60670-24 which should be shock proof and double insulated. IP65 in accordance with IEC 60529 (EN 60529), weather proof, Corrosion free, Acid & Chemical Resistant, temperature resistance, Made of material Polycarbonate for Lid part and PS (polystyrene) for Base with transparent lid, sealable. halogen & Silicone free recyclable material, .The gasket material shall be Polyurethane, while the gasket shall be internally embedded. The enclosure is Consisting PE and N FIXCONNECT® terminal with provision for cable entry through top, bottom and sides. The impact strength of enclosure i.e. the Degree of Protection against Mechanical load shall be in accordance with IEC 62262 for IK 08 (5 Joule).And Enclosure should withstand Glow wire test at 750°C in accordance with IEC 60695-2-11 flame retardant, Self Extinguishing, UL subject 94,V-2. Color: Grey, RAL 7035.Suitable for indoor installation and outdoor installation, protected against weather influences complete all as specified and directed by Engineer-in-Charge.
All as per item Serial No. 26 above but MCB DB SPN 4 way complete all as specified and as directed by the Engineer-in-Charge.
All as per item Serial No. 26 above but MCB DB SPN 8 way complete all as specified and as directed by the Engineer-in-Charge.
All as per item Serial No. 26 above but MCB DB SPN 12 way complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair MCB SP, 6-32 Amps, 240/415 volt,10 KA, 'B' curve ISI marked, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair MCB SPN, 40 Amps, 240/415 volt,10 KA, 'B' curve, ISI marked, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair MCB SPN, 63 Amps, 240/415 volt,10 KA, 'B' curve, ISI marked, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair MCB three pole and neutral, 415 Volts, 63-100 Amps, 16 KA, 50 Hz, 'C' curve, ISI marked, complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying in repair sub main wiring with two run of 2.5 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 2.5 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked, multi stranded copper conductor as earth continuity conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and including PVC conduit medium grade, ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supply and laying in repair sub main wiring with three run of 10 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 10 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked, multi stranded copper conductor as earth continuity conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and including PVC conduit medium grade, ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Four runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core, 6 sq mm nominal cross section cable with PVC insulated aluminium conductor multistranded served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old U/S existing cable complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core, 10 sq mm nominal cross section cable with PVC insulated aluminium conductor multistranded served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old U/S existing cable complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing as in repair PCB unit suitable for BLDC ceiling fan of 1200mm sweep single phase, 240 volts, of any make, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, modular PVC sheet/cover plate 3 way suitable for fixing switch/socket/fan regulators, etc on existing MS boxes of any make, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, modular PVC sheet/cover plate 4 way suitable for fixing switch/socket/fan regulators, etc on existing MS boxes of any make, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, modular PVC sheet/cover plate 6 way suitable for fixing switch/socket/fan regulators, etc on existing MS boxes of any make, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, modular PVC sheet/cover plate 8 way suitable for fixing switch/socket/fan regulators, etc on existing MS boxes of any make, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing as in repair, modular PVC sheet / cover plate 12 way suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing as in repair GI/MS (terminal boxes) rectangular block with earth dolly duly painted internally and externally with two coats of anti corrosive paint over a coat of red oxide primer including provision of new 3 modular cover plate over sunken box fixed with brass screw and cup washer for mounting, modular switches, sockets outlets, fan regulator etc. complete all as specified and as directed by the Engineer-in-Charge.
All as per above item No. 45 but with provision of new 4 module cover plate complete all as specified and as directed by the Engineer-in-Charge.
All as per above item No. 45 but with provision of new 6 module cover plate complete all as specified and as directed by the Engineer-in-Charge.
All as per above item No. 45 but with provision of new 8 module cover plate complete all as specified and as directed by the Engineer-in-Charge.
All as per above item No. 45 but with provision of new 12 module cover plate complete all as specified and as directed by the Engineer-in-Charge.
All as per above item No. 45 but with provision of new 1 module cover plate complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing as in repair, MCCB, 4 pole, 63 Amp, 415 Volts, 16 KA , fixed type including fixing arrangement, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing as in repair, MCCB, 4 pole, 100 Amp, 415 Volts, 25 KA , fixed type including fixing arrangement, complete all as specified and as directed by the Engineer-in-Charge.
Disconnecting electric/water supply connection, taking down carefully geyser of any capacity, depositing to MES store yard for repair and refixing the same after repair at desired location complete all as specified and directed by Engineer-in-Charge.
Supply and replacing inner tank made from copper sheet for geyser of 25 Ltr capacity including taking out old unserviceable inner tank of any description complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for painting with two coats of synthetic enamel paint over a coat of red oxide primer to Geyser of any capacity and writing the MES No after preparing the old painted surfaces by scraping, rubbing and cleaning the dust, rust etc existing painting complete all as specified and directed by Engineer-in-Charge.
Material and labour for Glass wool packing of required quantity to cover the 25 Ltr /50 Ltr copper shell to avoid the heat conduction including taking out old glass wool packing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of mild steel powder coated outer body of water storage heater (Geyser) suitable for 25 Ltr capacity as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, heating element, cup or triangle type of 2 KW as required at site for geyser of any make and any descriptions all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, thermostat switch for geyser of any type, ISI marked, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, geyser inner tank assembly suitable for geyser capacity of 25 Litre, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, heating element, 2 KW, having inbuilt thermostat as required at site for geyser of any make and descriptions complete, all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, brass chromium plated non return valve 15mm bore with air lock release arrangement, ISI Marked, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, metal clad socket top as per existing socket complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, inspection cover of stainless steel in 2 piece suitable for geyser of 50/25 ltr capacity and having provision of fixing indicator lamps, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for new grouting of 12 x 100 mm bolt in stone or bricks masonary wall with 1:4 CM for geyser of any description complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement flexible cable PVC insulated and sheathed, 3 core, circular multi stranded copper conductor of 1.50 Sqmm complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair PVC connection pipe 450mm long having wire mesh coating over it with brass nuts and washers suitable for connecting geysers inlet and outlet to GI tubing complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair, top plug 15 Amp, 3 pin, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, indicating lamp green/red in colour 230 volts as per existing make, complete all as specified and as directed by the Engineer-in-Charge.
Taking down ceiling/exhaust/wall mounted/pedestal fans of any sweep of any make with down rods, blades canopy etc by disconnecting the electric connections and deposit at fan store of AGE E/M north for issuing of fan to contractor for repair, and collecting the fan after repair and hanging the same at location as directed by the concerned JE E/M complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for opening the stator & rotor of the 1200mm sweep ceiling fan, cutting the existing worn winding and rewinding the fan with superior quality copper wire and filling the varnish as insulation between each winds & covering each loops of winding by sleeves and paper & reassembling of complete fan by fixing serviceable old and new parts of fans i.e. rubber bush, condenser and shackle housing , gun metal bushes, ball bearings, twin twisted copper cable, down rod assembly & canopy ,split pins complete all as per manufacturers design air delivery including greasing, oiling & testing of fans all as per manufacturers design & speed complete all as directed & approved for 1200mm sweep. Notes for item NO (i) to (vii) :- (i). The quoted unit rate shall be deemed to be inclusive of taking out defective parts and fixing of new parts. All new parts shall be measured and paid wide relevant items of the schedule. (ii). The rates for refixing and taking out serviceable parts shall be deemed to be included of quoted unit rates. (iii). New parts shall be of respective makes of fans. (iv). The quoted unit rates shall also include writing of MES No on fans (v). Unserviceable /defective retrieved parts shall be credited under sch of credit. (vi). After assembling all fans shall be tested for the speed as directed. (vii). All the fans shall be repaired/rewind at AGE E/M store yard only.
Description all as per serial item No 71 here-in-before but for Exhaust fans of 225/250mm sweep, complete all as specified and as directed by the Engineer-in-Charge.
Description all as per serial item No 71 here-in-before but for Exhaust fans of 300mm sweep, complete all as specified and as directed by the Engineer-in-Charge.
Description all as per serial item No 71 here-in-before but for Wall mounting 450mm sweep, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for cleaning the fan motor assembly body, blade of ceiling fan, filling the cavity, rubbing with sand paper, taking off old paint with the help of chemicals and painting the ceiling fan/Exhaust fan with one coat of superior quality synthetic enamel paint including writing the MES number on the ceiling fans of 1200mm sweep with black colour synthetic enamel paint including greasing complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, mild steel louver and shutter self openable/closable for 300mm sweep, exhaust fan, superior quality complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing Thermoplastic enclosure in accordance with IEC 62208:2011 with IP 66 degree of protection as per IEC 60529 ,protection class II ,Rated insulation voltage Ui = 1000 V AC/DC. Made of material Polycarbonate for Lid part and PS (polystyrene) for Base with transparent hinged lid. The impact strength of enclosure i.e. the Degree of Protection against Mechanical load shall be in accordance with IEC 62262 for IK 08 (5 Joule).Glow wire test IEC 60695-2-11: 750 °C UL Subject 94: V-2,flame-retardant ,self-extinguishing, Ambient temperature Maximum value + 60 °C and Minimum value - 25 °C. Colour: grey RAL 7035.The gasket material shall be Polyurethane, while the gasket shall be internally embedded. Enclosure should be Shock proof, Rust Proof, Corrosion Free, Acid & Chemical Resistant, UV Resistant, Silica and Halogen Free recyclable material. Multi level knockouts for cable glands in different sizes. The pre-moulded knockouts shall be available on top and bottom of the enclosure to enable cable entries from both direction. Lid fasteners will be tool operated it will be sealable with accessories. Suitable for indoor installation and outdoor installation, protected against weather influences complete all as specified and directed by Engineer-in-Charge. Cat part No. KG 9002 of make Hensel or equivalent in Schnieder/Hager/GE Power
All as per ser item No. 77 but cat part No. KG 9003 of make Hensel or equivalent in Schenieder/Hager/GE Power.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron. Earth wire protected by GI pipe 15mm bore(medium grade) and connected to earthing test point as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing as in repair complete all as directed by Engineer-in-Charge and earth testing on completion .
Supply and fixing in repair, LED Bollard 8-10 watt, IP-65 , 6500 K luminaire made of pressure die cast aluminium housing and clear glass , 240 volt, 50HZ, AC supply , complete with all accessories including electronic driver, internally pre wired including connecting with three core flexible copper conductor cable from Electric Supply Source to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, Solar LED post top luminaire 20W- 25W, 5700K, IP-65 made of pressure die-cast aluminium housing & clear glass 240 volt, 50HZ, AC supply complete with all accessories, including electronic driver, internally pre wired including provision of 3 core PVC flexible copper conductor from electric supply source to connector of the light, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, LED post top luminaire 20W- 25W, 5700K, IP-65 made of pressure die-cast aluminium housing & clear glass 240 volt, 50HZ, AC supply complete with all accessories, including electronic driver, internally pre wired including provision of 3 core PVC flexible copper conductor from electric supply source to connector of the light, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, LED 7 watt, warm white bollard made of extruded aluminium housing, to redefine landscape with better light quality and enhance architectural design IP-65 , 3000K luminaire, 240 volt, 50HZ, AC supply , complete all as specified and as directed by the Engineer-in-Charge. Make-Cat Part No. LB14880-XXX-65-08 of make Wipro or equivalent makes mentioned in list of make attached as Appendix ‘B’ of CA.
Supply and fixing in repair, heritage post top lantern suitable for B-22 lamp made up of die cast aluminium housing with glare free optically designed PC diffuser complete all as specified and directed by Engineer-in-Charge. Cat Part No. SLEPT 30 W-HARY of make Surya or equivalent makes mentioned in list of make attached as Appendix ‘B’ of CA.
Supply and fixing in repair, electronic meters temper proof LCD display with polycarbonate cover, 230V, 10-60 amps, accuracy class-I 50 Hz, conforming to IS 13779, IP-54 with parameters to show data , time, current reading, load, PF, voltage and kWH complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair, electronic meters temper proof LCD display with polycarbonate cover, 3 Phase, 415 volts, 10-60 amps, accuracy class-I 50 Hz, conforming to IS 13779, IP-54 with parameters to show data , time, current reading, load, PF, voltage and kWH complete all as specified and directed by Engineer-in-Charge.
Supply, fixing, installing and testing of cast iron vintage pole 1.20m to 1.50m height with double Bracket arms with base plate including necessary PCC foundation and fixed with nuts and bolts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing as in repair PVC rigid conduit 25 mm dia medium grade fixed on wall/on ground with coupler, lock nut, saddles, pipe hooks etc. including all fitting such as Tee, bend, elbow, reducer, bell mouth tube end etc. complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of cover for VTPN DB made up of particle board of 8 mm thick of size 400 x 700 mm including locking arrangement complete all as specified and directed by Engineer-in-Charge.
Material and labour for PVC conduit 15mm dia with all accessories such as bend, T, socket etc and 1 run of 1.0 Sqmm copper wire (White) drawn through including cutting and chasing in wall for inverter circuit complete all as specified and directed by Engineer-in-Charge.
Supply and fixing as in repair, LED decorative gate pillar boundary light 12 watt aluminium housing half oven downlighter, waterproof, suitable for exterior wall complete all as specified and directed by Engineer-in-Charge.
Supply and fixing heavy duty exhaust fan 300mm sweep with corrosion resistant steel body, minimum noise, operation and maintenance free design, totally enclosed, highly efficient, heavy duty motor with pressure die cast aluminium rotor mounted on double ball bearings, aerodynamically contoured blades, steel base frame with rubber mountings for silent operation, 6 pole, maximum watt input not more than 90 watt, 900 RPM, minimum air delivery 1710 cum/hour with metal blades and shutter type louvers self-openable/ closable for protecting the entrance of birds as per IS :2132-1967 and testing complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing heavy duty exhaust fan 450mm sweep with corrosion resistant steel body, minimum noise, operation and maintenance free design, totally enclosed, highly efficient, heavy duty motor with pressure die cast aluminium rotor mounted on double ball bearings, aerodynamically contoured blades, steel base frame with rubber mountings for silent operation, 6 pole, maximum watt input not more than 90 watt, 900 RPM, minimum air delivery 1710 cum/hour with metal blades and shutter type louvers self-openable/ closable for protecting the entrance of birds as per IS :2132-1967 and testing complete all as specified and as directed by Engineer-in-Charge.
Supply, fixing and testing water heater (Geyser) metal outer body with copper tank of capacity 25 ltrs including all accessories like, NRV, heavy duty PVC Connection and making good to surface area with new hold fastener connection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing as in repair of modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of modular socket outlet 2/3 pin combined, 6 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of modular socket outlet 3/3 pin combined, (6pin), 6/16 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of modular bell push 6 Amp, 1 way, 1 module, 230 volts complete all as specified and as directed by the Engineer-in-Charge.
Note:- Amount of credit of Rs. 1,31,766.00 for retrieved materials is mentioned in Schedule of Credit Page No. 97 (R) & 98 (R) of tender documents in pdf form which will be deducted offline while acceptance of tender.
Saurav Enterprises
S.R. Constructions
R N Enterprises
Mohinder Pal and Sons
M/s Prakash Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .