Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹27.3 L | L1 | Accepted-AOC Accepted being lowest quoted rate |
| 2 | L2₹28.3 L+₹93,913 (3.44%)Rejected-AOC 2 A NARENDRA APPARTMENT CENTRAL JAIL ROAD SUBHASH BRIDGE AHMEDABAD 380027 | AHMEDABAD | AHMEDABAD | GUJARAT | 380027 | ₹28.3 L+₹93,913 (3.44%) | L2 | Rejected-AOC Not accepted since higher quoted rate |
| 3 | L3₹30.0 L+₹2.6 L (9.68%)Rejected-AOC | ₹30.0 L+₹2.6 L (9.68%) | L3 | Rejected-AOC Not accepted since higher quoted rate |
| 4 | L4₹30.3 L+₹2.9 L (10.7%)Rejected-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | ₹30.3 L+₹2.9 L (10.7%) | L4 | Rejected-AOC Not accepted since higher quoted rate |
| 5 | L5₹30.4 L+₹3.1 L (11.3%)Rejected-AOC | ₹30.4 L+₹3.1 L (11.3%) | L5 | Rejected-AOC Not accepted since higher quoted rate |
Tender Value
₹28.8 L
EMD Value
₹57,600
Closing Date
22 Jul 2020, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
PROVN OF LT UG CABLE AND ALLIED WORKS AT VAIROUS LOCATIONS AT MIL STN DHRANGADHRA
2020_MES_357923_1
GE(A)/GNR/TOKEN/39 of 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
MIL STN DHRANGADHRA
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹57,600
Yes
7 Sept 2020
3 Jul 2020
24 Jul 2020
3 Jul 2020
22 Jul 2020
9 Jul 2020
3 Jul 2020 - 8 Jul 2020
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole, laying of cables etc in hard/dense soil and getting out all as specified and as directed.
Excavating in trenches not exceeding 1.5m wide and exceeding 1.5 m but not exceeding 3.00m in depth for foundation of pole, laying of cables etc in hard/dense soil and getting out complete all as specified and directed..
Returning, filling in, including spreading, leveling, watering and well ramming in layer not exc 25 cm with soil obtained from excavation all as specified and as directed.
M&L, for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note: Depth after punning shall be measured and paid.
Removing excavated material (Soil) not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point all as specified and as directed.
Supply and laying, sub class old 'B' burnt bricks, size of brick 230x115x75mm, laid as cable protection cover complete all as specified and directed.
M&L for plain cement concrete (1:4:8) type D2, using 40 mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed.
M&L for cement concrete (1:3:6), type C-1, using 20mm graded stone aggregate in coping and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed.
Supplying and laying, GI pipe, 40mm dia, light grade, laid under road, fixing to poles / walls with necessary clamp and taking out existing unserviceable pipe complete all as specified and directed.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-31 (09 Mtr long) including two coats of bituminous paint internally and externally for the portion embedded in concrete and two coats of aluminium paint over one coat of red oxide primer to external/exposed surfaces complete all as specified and directed . Note:- Excavation/PCC shall be measured and paid separately under relevant items
S&F, bracket made out of light grade, Galvanised steel tube, 25mm bore, 1.5 Mtr length, bent to 120 degree for fixing street light fitting at the top, fixed to pole with necessary clamps made out of FI 40mm x 5mm with nuts & bolts including preparation of steel surfaces & apply two coat of synthetic enamel paint over red oxide primer complete all as specified and directed.
M&L for horinzontal borring under the road in soft/loose strata for insertion of GI tube up to 80mm bore all as directed.
Supplying & laying, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete including taking down old unserviceable cable all as specified and directed of 10 Sqmm, 4 Core cables. Make. Havells/Polycab/Plaza.
Supplying & laying, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete including taking down old unserviceable cable all as specified and directed of 16 Sqmm, 4 Core cables. Make. Havells/Polycab/Plaza.
Supplying & laying, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete including taking down old unserviceable cable all as specified and directed of 35 Sqmm, 3.5 Core cables. Make. Havells/Polycab/Plaza.
Supplying & laying, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete including taking down old unserviceable cable all as specified and directed of 70 Sqmm, 3.5 Core cables. Make. Havells/Polycab/Plaza.
S&F, PVC junction box, factory made, size 180x290x110mm with one No SP MCB of 06 Amp rating, class-B and 3 Nos connector fixed on pole with necessary clamps and bolts etc duly painted with two coats of aluminum paint over a coat of red oxide primer including connecting with street light cable complete all as specified and directed.
S&F, PVC insulated and PVC sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, passing throuth pipe, on pole/wall from juntion box to street light fitting complete all as specified and directed.
S&F, heavy duty, non metalic, PVC conduit of 25 mm bore including all fitting such as bends, elbow, coupler lock nut etc, fixed on pole with clamp including taking down old PVC conduit of any type complete all as specified and directed.
S&F, New LED flood light fitting of 70/72 Watts, IP-66, in pressure die cast housing with epoxy power coated, prismatic polycarbonate cover/toughtened glass with and including individual LED lenses alongwith electronic driver upto 10 KV surge protection duly conneted with wire of suitable capacity complete all as specified and directed as per make of Chrompton/Wipro/Philips/Jaquar.
M&L, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth strip of 25x4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using earth strip of 25x4mm as earth lead all as specified and testing on completion including provision of earth lead protected by 40 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 40 mm bore light grade 7.5m.
Supply, installation, commissoning and testing, feeder pillar board, Kiosk type, LT Panel (415 Volts, 50 Hz , 3-phase, 4 wire supply), plinth mounted, factory made, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 50mm x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.5 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:- (a) Incoming supply:- (i) Aluminium bus bar chamber 200 amps rating of 04 strip - 01 No (ii) MCCB, thermal and megnatic setting, 4 pole, AC, 415 volts, 160 Amp rating, 35 KA rupturing capacity - 01 No (iii) Digital type multifunctional meter showing V. A. Hz etc. - 01 No (iv) Indicatiing lamp Neon type for R-Y-B - 3 Nos (b) Outgoing supply:- (i) MCCB, thermal and meganitic setting, 4 pole, AC, 415volts, 63 Amp rating, 16 KA rupturing capacity - 04 No (ii) MCCB, thermal and meganitic setting, 3 pole AC 415 volts, 100 Amp rating, 16 KA rupturing capacity - 02 No. (iii) Time switch, single phase, 230 volts with 24 hours time setting, current 16 Amps and with AC relay type ML-3 and with MCB TPN, C Curve, 32 Amps, three phase including Internal connections - 01 No.
Supply, installation, commissoning and testing, feeder pillar board, Kiosk type, LT Panel (415 Volts, 50 Hz , 3-phase, 4 wire supply), plinth mounted, factory made, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 50mm x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.5 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:- (a) Incoming supply:- (i) Aluminium bus bar chamber 250 amps rating of 04 strip - 01 No (ii) MCCB, thermal and megnatic setting, 4 pole, AC, 415 volts, 200 Amp rating, 35 KA rupturing capacity - 01 No (iii) Digital type multifunctional meter showing V. A. Hz etc. - 01 No (iv) Indicatiing lamp Neon type for R-Y-B - 3 Nos (b) Outgoing supply:- (i) MCCB, thermal and meganitic setting, 4 pole, AC, 415volts, 100 Amp rating, 16 KA rupturing capacity - 02 No (ii) MCCB, thermal and meganitic setting, 3 pole AC 415 volts, 63 Amp rating, 16 KA rupturing capacity - 04 No. (iii) MCB SPN, C-curve, 32 Amps, AC 230 Volt - 01 No, (iv) Time switch, single phase, 230 volts with 24 hours time setting, current 16 Amps and with AC relay type ML-3 and with MCB suitable size, 32 Amps, three phase including Internal connections - 02 No.
Shree Krushna Supply Corporation
Singh Engineer And Contractor
Electricals India
Sai Ram Electricals and Refrigeration Works
Tech Serve Solutions
Badri Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .