Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-Finance | L1 | Accepted-Finance Lowest Bidder. | |
| 2 | L2₹13.4 L+₹1.1 L (8.51%)Accepted-Finance 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | L2 | Accepted-Finance L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical 355 85 GALI NO 16 ASHOK VIHAR PHASE II BHIM GARH KHERI ASHOK VIHAR PHASE II GURGAON GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122001 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹15.0 L
EMD Value
₹30,000
Closing Date
9 Sept 2020, 2:00 pmClosed
AEE Electrical
AEE Electrical,CSIR-IHBT, Palampur
Air conditioning of Greenhouse for Heeng
2020_CSIR_56423_1
5-214/Ws/20
Open Tender
Electrical Works
Works
90 days
CSIR-IHBT, Palampur
As per NIT and contract document
2 documents required · 2 mandatory
₹500
Director
₹30,000
11 Sept 2020
31 Aug 2020
10 Sept 2020
31 Aug 2020
9 Sept 2020
1 Sept 2020
31 Aug 2020 - 9 Sept 2020
Amount
Supplying, Installing, Commissioning and testing of high temp air cooled Refrigeration system having indoor unit of 80,000 Btu/Hr nominal capacity, 12000 cfm air flow rate, powder coated body suitable for operation on 3 phase 415 V, 50 c/s AC supply and having scroll compressor with Eco-friendly Refrigerant R-404 Gas, weather proof polyster powder coated canopy permanently lubricated & thermocally protected fan motors and fitted with all safety and control devices required for system protection/ operation, Suitable for operation on 3 phase 415 V, 50 c/s AC supply . The machine should be compatible to maintain Greenhouse inside temp 17+/-2 degree Celsius complete as required. (Make: Blue Star, Model RUAH-08024 or equivalent in Carrier/Hitachi/O General).
REFRIGERANT COPPER PIPING: Supply & fixing of 7/8" & 5/8" dia or suitable size as per design, Hard Drawn Copper pipes 20 SWG thick, i/c of Elbow, Tee, Connector etc. jointing soldering , supporting structure etc. as required. (Make: Mandev/Totalline)
CABLE TRAY: Supplying & installing following size of perforated painted with powder coating MS cable trays with perforation not more than 17.5 % in convenient sections, joined with connectors, suspended from the ceiling with MS suspenders including bolts & nuts, painting suspenders etc. as require (a) 100mm widthx50mm depthx1.6mm thickness.
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia GI pipe from earth electrode including connection with copper thimble excavation and refilling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Providing and fixing GI Pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall i) 20 mm dia nominal bore (NOTE: PVC pipe for interlocking G.I. pipe etc. will be provided without any extra cost.)
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying priming coat of approved steel primer using structural steel etc. as required. i) In grating, frames, guard bar, ladder, railings, brackets, gates and similar works. (Make: Kamdhenu/Jindal).
Supplying and fixing following, PVC insulated copper conductor multi core unarmoured cable for control wiring on existing tray, end termination glands, lugs etc. as required: i) 4x1.5 sq.mm. ( Make: KEI/ Anchor/ Finolex/ Polycab)
Supplying and fixing following, PVC insulated copper conductor multi core unarmoured cable for control wiring on existing tray, end termination glands, lugs etc. as required: i) 4x10 sq.mm. (Make: KEI/ Anchor/ Finolex/ Polycab)
Supplying & fixing 5 amp. To 32 amp. Rating, 240/ 415 volts, 10 ka, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Tripple Pole and Neutral
S/F 50W LED Energy saving, environmental friendly, long life, exclusive innovative die-cast Aluminium flood light with high power LEDs as light source, suitable for Area lighting. (Make: Philips/Bajaj/Wipro)
S/F Single phase, 230 Volt, 50 Hz, 450 mm sweep 1400 RPM Heavy Duty Exhaust Fan with Pre-lubricated double ball bearing for maintenance free running having noise level 55 dB - 60 dB (Make: Havells/Bajaj/Crompton)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. i) 2x1.5 sqmm + 1x1.5 sqmm earth wire
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI/ PVC box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc as required. i) Group C
VOLKS ENERGIE PVT LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .