Major S N Gaikwad
Holta Cantt Palampur
REPAIR MAINTENANCE AND REPLACEMENT OF LT AND APFC PANELS SWITCHGEARS SERVICE CABLES AND MISC WORKS AT ALHILAL MIL STN
2023_MES_616607_1
GEP-56/2023-24
Open Tender
Civil Works
Item Rate
180 days
Alhilal Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
GE Palampur
₹20,000
28 Nov 2023
31 Aug 2023
2 Oct 2023
31 Aug 2023
29 Sept 2023
15 Sept 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts / stays etc including taking out cable cover or stone slab, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed.
Removing excavated any type of soil to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed.
S&F 40mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
S&F 50mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
S&F 80mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
S&F in replacement digital voltmeter in 96x96 Sqmm three phase class 1.0 including making necessary connection in existing panel complete all as specified and directed.
S&F in replacement digital ammeter in 96x96 Sqmm three phase class 1.0 including making necessary connection in existing panel complete all as specified and directed.
S&F in replacement neon indicator lamp with holder assembly RYB including making necessary connection in existing panel complete all as specified and directed.
S&F in replacement CT coil of existing capacity including making necessary connection in existing panel complete all as specified and directed.
Cutting and removing existing wild grass, vegetation, creepers, small plants/bushes etc. clamping up towards the poles and stays etc including cleaning bottom surface area of pole & stay not less than 1m x 1m by surface dressing of earth outside and inside substations, perimeter fencing around pump house area, and in drains surrounding area from site complete all as specified and directed.
S&F in replacement synthetic insulation mat 2m x 1m x 10mm complete all as specified and directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 120sq.mm 3 1/2core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 95sq.mm 3 1/2core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 70sq.mm 3 1/2core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 50sq.mm 3 1/2core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 35sq.mm 3 1/2core including taking out old unserviceable cable complete all as directed.
M&L old size brick class "B" as in cable protection laid dry,flat,transversally along the length of cable on sand cushioning with width equalto length of the brick complete all as specified and as directed.
S&F in replacement MCCB, AC, 415 volts, 250 amp, 35/36 KA, 4 pole, adjustable microprocessor release including making necessary connection in existing panel complete all as specified and directed.
S&F in replacement MCCB, AC, 415 volts, 160 amp, 35/36 KA, 4 pole, adjustable microprocessor release including making necessary connection in existing panel complete all as specified and directed.
S&F in replacement MCCB, AC, 415 volts, 125 amp, 35/36 KA, 4 pole, adjustable microprocessor release including making necessary connection in existing panel complete all as specified and directed.
S&F in replacement MCCB, AC, 415 volts, 100 amp, 35/36 KA, 4 pole, adjustable microprocessor release including making necessary connection in existing panel complete all as specified and directed.
M&L preparation of existing old steel painted surface of panels of any size and any height, apply one coat of synthetic enamel paint inside and outside of panel (strictly existing shade) over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L welding existing broken panel doors (any number of shutters) and welding good quality hinges (any size any number of hinges per panel) of stuiable size for making open and close the panel doors including bends etc. and fixing locking arrangement of the doors complete all as specified and directed.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed.
Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as required.
M&L inspection, checking and repair to APFC panel by cleaning of dust inside with blower, cleaning of moving part/contract from CT cleaner, tightening of lose parts/electrical wiring, cleaning of contractors, relays and capacitor junction points, oiling of cooling fan, complete testing of APFC relay with necessary settings with CTs/load adjustments to match with the APFC load management system complete with replacement of burnt/worn out unserviceable components/burnt wires thimbles/lugs etc for APFC panel capacity 50 KVAR to 150 KVAR complete all as specified and directed. Note: All unserviceable parts shall be measured and paid separately as supply onlyl. Replacement of small nuts/screws, wires lugs or thimles and cleaning material cost included in this item.
Supply only MCB, TP 6 to 32 amp 10 KA C curve for existing APFC panel complete all as sepcified and directed.
Supply only MCB, TP 40 to 63 amp 10 KA C curve for existing APFC panel complete all as sepcified and directed.
Supply on auxillary contractor 1 NO+1NC TP 415 volts suitable for 10 KVAR rating for existing APFC panel complete all as specified and directed.
Supply on auxillary contractor 1 NO+1NC TP 415 volts suitable for 20 KVAR rating for existing APFC panel complete all as specified and directed.
Supply only capacitor 440 volts 50 Hz 5 KVAR for existing APFC panel complete all as specified and directed.
Supply only capacitor 440 volts 50 Hz 10 KVAR for existing APFC panel complete all as specified and directed.
Supply only capacitor 440 volts 50 Hz 15 KVAR for existing APFC panel complete all as specified and directed.
Supply only capacitor 440 volts 50 Hz 20 KVAR for existing APFC panel complete all as specified and directed.
Supply only CT's suitable for ampere meter 100/5A ratio for existing APFC panel complete all as specified and directed.
Supply only CT's suitable for ampere meter 200/5A ratio for existing APFC panel complete all as specified and directed.
Supply only APFC relay square flush type with protection devices intelligent auto processor based on electonic controller unit 6 stages for existing APFC panel complete all as specified and directed.
Supply only APFC relay square flush type with protection devices intelligent auto processor based on electonic controller unit 8 stages for existing APFC panel complete all as specified and directed.
Supply only MCCB, AC, 415 volts, 100 Amp, 25KA, 4 pole, fixed thermal magnetic release for existing APFC panel complete all as specified and directed.
Supply only MCCB, AC, 415 volts, 160 Amp, 25KA, 4 pole, fixed thermal magnetic release for existing APFC panel complete all as specified and directed.
M&L 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm dia suspension GI wire with stranded conductor 06 sqmm twin core cable flat or circular including taking down old unserviceable cable and stacking at site complete all as specified and directed.
M&L 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm dia suspension GI wire with stranded conductor 10 sqmm twin core cable flat or circular including taking down old unserviceable cable and stacking at site complete all as specified and directed.
Taking out old unserviceable APFC panel design, supply and fixing automatic correction to unit correction to unit power factor panel complete of capacity 100 KVAR to achieved th PF from 0.9 to 1.0 with five stagging (50 + 25 + 15 + 5 +5), modular design, siemens grey colour protection IP-20 with advance micro processing based IPFC, switch option auto and manual, incomming as MCCB 200 amps four pole with rapturing design 35 KA, indicator lamp for step on indication, bus bar with copper as manufacturer's design suitable to match the incomming current, Ref Standard: IEC 61921/IS 8623 complete all as specified and directed. Note:- (i) Rate of capacitor bank deemed to included in unit quoted rate. (ii) All type of spares such as glands, lugs, nuts, bolts etc necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (iii) Drawing of panel shall be approved by GE before fabrication.
M/s Sheetal Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .