| 1 | L1₹21.3 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | ₹21.3 L Quoted ₹21.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹25.6 L+₹3.6 L (16.6%)Rejected-AOC | ₹25.6 L+₹3.6 L (16.6%) | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical 01 CHANGSARI KAMRUP ASSAM 781101 | KAMRUP | ASSAM | 781101 | - | - | Rejected-Technical Not approved for opening of Cover 2 due to not having cat b(ii) required as per NIT and also not submitted any document in support of similar work experience. |
| Sl No | Description | Qty | Unit | M/s PRABIR ENTERPRISE L1 | M/S A D ASSOCIATES L2 |
|---|---|---|---|---|---|
| 1.00 | Material & Labour for Dismantling steel poles/struts, any size of HT OH line by taking necessary shut down, dismantling OH line conductor and shifting to MES store yard keeping in safe custody to issue under Schedule of credit complete all as specified and as directed. | 2 | Each | 500 ₹1,000 Lowest | 1,200 ₹2,400 |
| 2.00 | M & L for steel tubular swaged pole 410 SP-64 (12.0 metre long) seamless type, including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of bituminious paint over a coat of red oxide zinc chrome primer on exposed portion and making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed.
Note- Excavation & Earthwork shall be measured and paid seperately. Volume occupied by steel pole shall be deducted to derive the quantity of PCC. | 2 | Each | 22,000 ₹44,000 Lowest | 40,000 ₹80,000 |
| 3.00 | Taking down existing rusted/worn out MS cross arm, MS Channel, angle, clamps, nuts, bolts and washers and supply and fixing new MS Cross arms, MS Channel, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide and one coat of aluminium paint complete all as specified and directed by Engr in charge. | 1 | Qtl | 400 ₹400 Lowest | 14,000 ₹14,000 |
| 4.00 | Taking down existing cracked/unserviceable Pin type insulator and supply and fixing new Pin type insulator porcelain vitreous white, brown or green including one galvanised mild steel spindle, two galvanised washers and one galvanised iron nuts 150 mm dia for 11000 volts grade complete all as specified and directed by Engr in charge. | 30 | Each | 350 ₹10,500 Lowest | 500 ₹15,000 |
| 5.00 | Taking down existing cracked/unserviceable Disc type insulator and supply and fixing new Disc type insulator porcelain vitreous 145 mm high and 255 mm dia ball and socket type (white, brown or green) complete single disc assembly for tension with tension clamps including cross arm strap, ball eye, socket eye & cotter pins suitable for ACSR conductor working pressure 11 KV (90 KN) grade complete all as specified and directed by Engr in charge. | 24 | Each | 400 ₹9,600 Lowest | 1,300 ₹31,200 |
| 6.00 | Material & Labour for Stay assembly diameter of stay rod in 20 mm incl stay insulator or egg insulator complete with all accessories as shown in electrical plate No. 1 and Incl dismantling existing stay assembly complete all as specified and directed. | 4 | Per Set | 1,100 ₹4,400 Lowest | 3,600 ₹14,400 |
| 7.00 | Taking down existing worn out/old/broken ACSR conductors of any size and length at any position from HT poles and supply, fixing and stretching new ACSR conductors of any size and type for over head HT poles including binding at site to insulator with suitable size of binding wire etc complete all as specified and directed by Engr in charge. | 5 | Qtl | 39,500 ₹1,97,500 | 22,000 ₹1,10,000 Lowest |
| 8.00 | Taking down unsv Danger notice plate of any size and M & L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size. | 10 | Each | 250 ₹2,500 Lowest | 375 ₹3,750 |
| 9.00 | M & L for Expulsion fuse single pole suitable for 11000 V of cap aboe 25 Amp upto 50 amp complete all as directed. | 3 | Each | 200 ₹600 Lowest | 3,000 ₹9,000 |
| 10.00 | M & L for Expulsion fuse single pole suitable for 11000 V of cap above 50 Amp upto 100 Amp complete all as directed. | 6 | Each | 200 ₹1,200 Lowest | 3,500 ₹21,000 |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
21 Oct 2025, 6:00 pmClosed
CWE LIKABALI
HQ CWE LIKABALI, MILITARY ENGINEER SERVICES, PIN 901266 C/O 99 APO.
REPAIR/ MAINTAINANCE OF HT EXTERNAL ELECTRIC INSTALLATION AND REPAIR AND MAINT OF SECURITY/PERIMETER LIGHTS/ HIGH MAST LIGHTS/ SOLAR LIGHTS/ GARDEN LIGHTS AND CONNECTED ITEMS AT SIGAR MIL STN
2025_MES_733353_1
83038/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Sigar
Please refer NIT
5 documents required · 5 mandatory
₹500
GE 872 EWS
₹54,000
Yes
26 Dec 2025
30 Sept 2025
23 Oct 2025
30 Sept 2025
21 Oct 2025
14 Oct 2025
Amount
Material & Labour for Dismantling steel poles/struts, any size of HT OH line by taking necessary shut down, dismantling OH line conductor and shifting to MES store yard keeping in safe custody to issue under Schedule of credit complete all as specified and as directed.
M & L for steel tubular swaged pole 410 SP-64 (12.0 metre long) seamless type, including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of bituminious paint over a coat of red oxide zinc chrome primer on exposed portion and making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed. Note- Excavation & Earthwork shall be measured and paid seperately. Volume occupied by steel pole shall be deducted to derive the quantity of PCC.
Taking down existing rusted/worn out MS cross arm, MS Channel, angle, clamps, nuts, bolts and washers and supply and fixing new MS Cross arms, MS Channel, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide and one coat of aluminium paint complete all as specified and directed by Engr in charge.
Taking down existing cracked/unserviceable Pin type insulator and supply and fixing new Pin type insulator porcelain vitreous white, brown or green including one galvanised mild steel spindle, two galvanised washers and one galvanised iron nuts 150 mm dia for 11000 volts grade complete all as specified and directed by Engr in charge.
Taking down existing cracked/unserviceable Disc type insulator and supply and fixing new Disc type insulator porcelain vitreous 145 mm high and 255 mm dia ball and socket type (white, brown or green) complete single disc assembly for tension with tension clamps including cross arm strap, ball eye, socket eye & cotter pins suitable for ACSR conductor working pressure 11 KV (90 KN) grade complete all as specified and directed by Engr in charge.
Material & Labour for Stay assembly diameter of stay rod in 20 mm incl stay insulator or egg insulator complete with all accessories as shown in electrical plate No. 1 and Incl dismantling existing stay assembly complete all as specified and directed.
Taking down existing worn out/old/broken ACSR conductors of any size and length at any position from HT poles and supply, fixing and stretching new ACSR conductors of any size and type for over head HT poles including binding at site to insulator with suitable size of binding wire etc complete all as specified and directed by Engr in charge.
Taking down unsv Danger notice plate of any size and M & L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size.
M & L for Expulsion fuse single pole suitable for 11000 V of cap aboe 25 Amp upto 50 amp complete all as directed.
M & L for Expulsion fuse single pole suitable for 11000 V of cap above 50 Amp upto 100 Amp complete all as directed.
Taking down existing old unserviceable Switch air break and supply and fixing of new Air break gang operated switch triple pole mechanically operated out door with all fitting/ accessories mounted on and including 11 KV porcelain insulator and steel channel frame GI operating rod 25 mm dia of suitable length with operating mechanism worked from ground level vertically or horizontal operated as per site requirement including locking arrangement for operating handle complete suitable for current rating 400 Amps 11 KV working pressure with 15 Insulators complete all as specified and directed by Engr in charge.
Taking down existing old unserviceable lightening arrester and supply and fixing of new lightening arrester of expulsion type 65 KA complete with all fitting 11000 volts grade non linear resistor type with bolts, nuts and washers complete all as specified and directed by Engr in charge.
Taking down old unserviceable mat of any type and size including M & L for synthetic Insulating Mat of size 2m x lm x 2.5 mm. complete all as directed.
Excavation in trenches for soft/loose soil for laying under ground cable, errection of poles and stays in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed by Engr–in–charge.
Description all as per Srl item No 14.00 here- in- before but exceeding 1.5 m depth and not exceeding 3.00 m in depth complete all as directed..
Returning, filling in including spreading, levelling, watering and well ramming in layers soft/loose soil not exceeding 25 cm thick complete all as specified and directed by Engr in charge.
Removing surplus excavated material to a distance not exceeding 50 mtr and depositing at a level n.exc 1.5 mtr above the starting point complete all as specified and directed by Engr in charge.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Copping of Electric Poles, etc., weathering slightly rounded or chamfered angle and throating, finishing all Exposed Faces of Concrete including necessary Formwork, complete all as specified and as directed.
Material and labour for providing cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in foundation & filling etc. mass concrete for poles complete all as specified and directed.
Material and labour for providing cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling complete all as specified and directed.
Supply & laying in replacement galvanized steel tubing of size 80 mm bore "light grade" with GI fittings in trenches/ under roads/ along pole/ wall for cable protection complete all as specified & directed.
Supplying and laying crushed stone aggregate of size 20mm to 40 mm grade around the 2 pole, 4 pole transformer & LT Panels etc. complete all as specified & directed.
M & L for spray painting of transformers (any type power or distribution)) of capacity 250 KVA ( in situ ) outdoor type, installed and located at different sites in scattered area under the GE including the following: - (a) preparation of old surfaces by cleaning, scrapping, rubbing/ polishing etc. complete. (b) Spray painting with two coats of synthetic enamel paint of approved make / quality all as directed at site. (c) Writing the SM MES No of transformer on MS body of transformer all as directed.
M&L for Dehydration and filteration of existing transformer oil at different location with filtration machine and heating system to get di-electric strength of oil 40 kV minimum without distrubing the power supply system including replacement of unserviceable silica jel and topping up/ replacement of unserviceable transformer oil complete all as specified and as directed. (Note- Transformer oil for filling/topping up and silica gel shall be measured and paid separately under relevant items of this schedule).
Supply only new transformer oil of dielectric strength not be less than 60kV and conforming to IS-335 of 1993 for filling / topping up oil of transformer up to disired level complete all as directed.
Taking proper shut down, disconnecting of distribution transformer outdoor type 11 kV /415 volts having capacity 250kVA, transportation to the workshop for repairs including opening of transformers cover, draining of oil, de-tanking of core and coil assembly, cleaning, washing of dust and dirt from all parts including core, tank and cooling tubes radiators etc., joint inspection for estimate, replacement of defective parts, assembly, stage inspection, re-tanking, oil filtration/ dehydration, fill dehydrated oil and fresh oil and testing the repaired transformers for all the routine tests as per IS 2026 (Part 1): 2011 with latest amendments. Note: - (a) Transformer oil shall be drained out by the contractor in suitable capacity mild steel drums to be arranged by the contractor. The said drained out transformer oil shall be refilled in the transformer duly dehydrated after repair and the cost thereof shall be measured and paid for separately under respective item of this schedule. (b) Rewinding of both HT & LT coil/ copper winding shall be measured and paid for separately under respective item of this schedule. (c) Transportation charges for transportation of transformer from site to workshop and after repair, workshop to site shall be borne by the contractor and cost thereof shall be deemed to be included in the unit rate quoted for this item. (d) The spare parts excluding nuts, bolts, washer shall be measured and paid for separately (e) The said transformer shall be repaired in reputed workshop as decided by the GE. (f) Testing of transformer after repair shall be carried out as per IS 2026 (Part 1): 2011 and the cost of testing shall be deemed to be included in unit rate quoted against this item. (g) The IR value of the dried winding before inserting the core in the shell shall be measured and recorded.
M&L for rewinding of HT / LT Coil (Primary and secondary winding) of 250 KVA Transformer using existing size, double paper covering with super enamel copper winding wires with proper gauge, conforming to IS : 2026 (Part-I) : 2011 (as per existing size, turns and insulation class including providing all insulation materials, gasket etc., ) suitable for 250 KVA tranformer and testing complete all as specified and directed including taking down/out unserviceable burnt copper winding for taking into credit.
S&F in repair tap changer assembly complete for transformer rating 250 KVA , including connecting up with HT coil and testing for varying voltage complete all as directed.
S&F in repair cast iron wheel of transformer of suitable size including nuts bolts, split pins welding works as required at site complete all as directed.
S&F in repair breather assembly complete with silica gel suitable for any model of transformer rating 250 KVA to air column of conservator tank complete all as directed.
M & L for blue colour Silicagel of good quaility complete new fixtures complete all as directed.
M & L for HT bush suitable for any model/capacity of transormer Indoor/outdoor rating upto 250 KVA complete all as directed.
M & L for LT bush suitable for any model/capacities of transformer Indoor/Outdoor rating upto 250 KVA complete all as directed.
S&F Arc horn rods made of aluminium suitable for any model of transformer rating 250 KVA complete all as directed..
S&F temperature guage suitable for transformer outdoor/Indoor type with GI nipple etc including testing of provision complete all as directed.
M & L for preparing and painting on steel tubular swaged pole 9.0/10.0 metre long ) including cross arms, GI brackets with two coats of aluminium paint over a coat of aluminium red oxide primer on exposed portion and including making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete as specified and as directed.
All as per item No 36.00 here-in-before but steel tubular swaged pole of 11.00 mtr long, two pole Structure complete all as directed.
All as per item no 36.00 here-in-before but steel tubular swaged pole of 12.00 mtr long, four pole Structure complete all as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe 'light grade' for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
M & L for earthing complete with copper plate earth electrode 600 mm X 600 mm X 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 20 mm X 3 mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe 'light grade' for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 4 mm dia galvanised iron or steel wire
All as per Item No 41 above but 32x6mm galvanised iron strip complete all as directed.
All as per Item No 41 above, but 20x3mm copper strip complete all as directed.
Re - stretching only existing ACSR of any size on HT pole including binding the ACSR with insulators, aluminium binding wire complete all as specified and as directed. Note : (i) One length shall be measured for complete span of 3 conductors & GI wire.
S&F LED Street Light Fitting 35 Watt 230 V, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and directed.
All as per item No 45.00 here-in-before but 60 watt LED street light, 230V AC outdoor type with IP 65/66 protection including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and directed
S&F LED Flood light 70 watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including Taking down Unserviceable Flood Light Fitting of any description from any Height, complete all as specified and directed
All as per item No 47.00 here-in-before but 100 watt LED Flood light, 230V AC outdoor type with IP 65/66 protection including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and directed
All as per item No 47.00 here-in-before but 120 watt LED Flood light, 230V AC outdoor type with IP 65/66 protection including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and directed
S&F post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.
S&F MCCB 63 Amp 4 Pole, 16 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connection and fixing to existing Panel Board including Taking down/out unserviceable MCCB, complete all as specified and as directed,
All as per item No 51.00 here-in-before, but MCCB 100 Amp capacity including taking down unserviceable MCCB complete all as specified and as directed
All as per item No 51.00 here-in-before, but MCCB 125 Amp capacity including taking down unserviceable MCCB complete all as specified and as directed
M&L Galvanised steel tubing Pipe 40mm bore (dia), light grade with bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc. including taking down old unserviceable complete all as specified and as directed.
S&F PVC insulated FRLS copper conductor wire 1.0 Sqmm, 3 Core, multistranded cable for Providing Connection from Street Light Fitting to Overhead Line and Junction Box including Taking down Unserviceable Wire of any description, complete all as specified and as directed.
S&F Solar LED Street Light 40/45 Watt with Luminary High Bright white LEDs with Aluminium Die cast Luminary body, cool white, IP65, 6500K, CRI>80, Viewing Angle 120deg, IEC Certified, GREEN and RED LED indication showing charging, fault or low battery complete including taking down unserviceable LEDs from pole of any height all as specified and as directed.
S&F Semi-integrated Solar Street light 30 Watt made up of Aluminium Pressure die cast (PDC) housing, IP65 (120 Lm/W) with an in built battery of capacity 30 Ah connected with Solar PV Panel of suitable size mounted on top of the pole and mounting clamp, inbuilt MPPT charge controller and PIR motion sensor for motion detection with connector, pin and accessories, including taking down unserviceable SPV module, Battery and Solar Street light complete all as specified and as directed. Note : 20 years performance warranty on solar panel SPV Module.
S&F 6 Mtr long GI Pole of 80 mm bore dia with Grouting rods, & Necessary hardware including PCC Pit of size 40x40x50 Cm in Cement Concrete 1:3:6 (20mm graded stone aggregate), including necessary Excavation in Hard/Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 metre and all as per specified and as directed including taking down unserviceable Pole structure complete all as specified and as directed
S&F Shock Proof, Rust Proof, Fire Retradrant, Non-transparent Kiosks Pole Box of size 270x170x120mm made of Engineering Plastic on Piece moulding for Outdoor type, Heavy duty with 4 No. insulated Alunminium Bus-bar of 60 Amp capacity, mounted on Unbreakable Insulators MCB SP, 10 Amp, complete with Aluminium Lugs of suitable size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable size Mild Steel Bolts, Nuts & Washers, etc. and duly Painted on Both Sides with Two Coats of Synthetic Enemel Paint over a Coat of Red Oxide Zinc Chrome Primer including Taking down Unserviceable Pole Box of any description from any Height, complete all as specified and as directed including taking down/out unserviceable pole box
M/S A D ASSOCIATES (BID ID -3464399)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tenderdocuments83038.pdf
Tender Documents • 1.75 MB
BOQ_821131.xls
BOQ • 0.97 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .